1. Introduction to Lloyd’s Register (LR)

Lloyd’s Register (LR) is the world’s oldest classification society, established in 1760 as a provider of classification and compliance services to the marine and offshore industries. With over 260 years of experience, Lloyd’s Register sets standards through its Rules and Regulations for ships, offshore units, and related installations, while offering technical advisory, certification, and digital solutions to support the maritime sector. LR Type Approval demonstrates that cables conform to recognised industry quality standards through a process of independent review and testing.

Lloyd’s Register Organization Overview

Founded

1760
London, United Kingdom

Headquarters

London
71 Fenchurch Street, EC3M 4BS

Ships in Class

30,000+
Vessels Worldwide

Seafarers Served

1,000,000+
Through Digital Platforms

Register Book Ships

180,000+
Merchant Ships ≥100 tonnes

Classification Rating

A1
Highest Quality Standard

Source: Wikipedia – Lloyd’s Register

Lloyd’s Register Historical Development

1760
The Society for the Registry of Shipping was set up by customers of Edward Lloyd’s Coffee House in Lombard Street, London. Retired sea captains employed to inspect and classify vessels at 16 UK ports.
1764
First Register Book published, listing vessels rated or classed after hull and equipment surveys. Ship hulls graded A-G, equipment graded 1-2. The phrase “A1 at Lloyd’s” originates from 1775-76 edition.
1799-1833
Disputes over classification system led to two rival Registers: the shipowners’ “Red Book” and the underwriters’ “Green Book”.
1834
Agreement reached to unite as Lloyd’s Register of British and Foreign Shipping, establishing a General Committee and charitable values. First Rules for survey and classification published.
1853
Thomas Menzies introduces the Maltese Cross symbol on classification certificates to denote ships built under special survey.
1884
LR surveyors begin stamping the LR brand into steel as proof of approval – a practice continuing today.
1914
Name changed to Lloyd’s Register of Shipping, reflecting increasingly international outlook.
2012
Converted to Lloyd’s Register Group Limited, wholly owned by Lloyd’s Register Foundation charitable trust.
2020
Maritime Decarbonisation Hub launched with LR Foundation to accelerate shipping’s transition to net-zero emissions.
2023
Lloyd’s Register OneOcean digital solutions platform launched, encompassing all digital and software capabilities.

Source: Lloyd’s Register Official – Our History

EspañolIntroducción a Lloyd’s Register (LR)

Lloyd’s Register (LR) es la sociedad de clasificación más antigua del mundo, establecida en 1760 como proveedora de servicios de clasificación y cumplimiento para las industrias marítima y offshore. Con más de 260 años de experiencia, Lloyd’s Register establece estándares a través de sus Reglas y Reglamentos para buques, unidades offshore e instalaciones relacionadas. La aprobación de tipo LR demuestra que los cables cumplen con los estándares de calidad reconocidos de la industria a través de un proceso de revisión y prueba independiente. El término “A1 at Lloyd’s” se originó en la edición de 1775-76 del Libro de Registro, donde A representaba la calidad más alta del casco y 1 el mejor equipo.

繁體中文勞氏船級社(Lloyd’s Register)簡介

勞氏船級社(LR)是世界上最古老的船級社,成立於1760年,為海洋和離岸工業提供分類和合規服務。擁有超過260年的經驗,勞氏船級社通過其船舶、離岸設施和相關裝置的規則和規定制定標準。LR型式認證證明電纜符合公認的行業質量標準,經過獨立審查和測試過程。「A1 at Lloyd’s」這個術語起源於1775-76年的登記簿版本,其中A代表最高船體質量,1代表最佳設備。勞氏船級社追蹤超過180,000艘100噸以上的商船,包括其所有權、運營商和船旗信息。

2. Lloyd’s Register Type Approval for Cables

Lloyd’s Register Type Approval provides confidence that selected vendors and suppliers are capable of providing the required standard of product components that a project requires. For cables, LR Type Approval ensures products meet the rigorous demands placed upon them in marine and offshore environments through independent third-party testing and certification.

What Lloyd’s Register Approves for Cables

Lloyd’s Register is known for the classification and certification of ships and inspects and approves important components and accessories, including life-saving appliances, marine pollution prevention, fire protection, navigation, radio communication equipment, deck gear, cables, ropes, and anchors. The Register includes onboard applications for marine pollution prevention, fire protection and life-saving apparatus, navigation, communications equipment and the cables that connect and power these applications.

Approval CategoryDescriptionStandards Referenced
Type ApprovalProduct certification for materials and componentsLR Rules, IEC, BS, NEK
Works ApprovalManufacturing facility certificationISO 9001, ISO 14001
Approved Service SupplierService provider certificationLR Quality Assurance
Marine Equipment Directive (MED)EU certification for marine equipmentEU MED 2014/90/EU
UK Marine Equipment Regulations (MER)UK certification for marine equipmentUK MER 2023

Source: Lloyd’s Register – Type Approval Services

LR Type Approval Test Specifications for Cables

LR Type Approval Test Specification Requirements

Lloyd’s Register Type Approval Test Specifications detail performance and environmental testing for electrical products in marine applications. The test specification must be read in conjunction with the Lloyd’s Register Type Approval Procedure. The edition of the National/International Standard or LR Rules current at the time of application for Type Approval is applied. Where a standard is subsequently amended or superseded, further testing in accordance with the new standard may be required before a certificate can be renewed.

Test CategoryTest ParametersStandards
Electrical Performance Tests
Conductor ResistanceMaximum DC resistance at 20°CIEC 60228
Insulation ResistanceMinimum 50 MΩ·km at 20°CIEC 60092-350
Voltage WithstandAC voltage test (3.5kV for 0.6/1kV cables)IEC 60502-1
Fire Performance Tests
Single Cable Flame60s flame application, self-extinguishIEC 60332-1-2
Bundled Cable Flame20 min burn, char ≤2.5mIEC 60332-3-22
Fire ResistanceCircuit integrity ≥90 min at 830°CIEC 60331
Environmental Tests
Smoke Density≥60% light transmittanceIEC 61034
Halogen Content≤0.5% HCl equivalentIEC 60754-1
CorrosivitypH ≥4.3, conductivity ≤10 µS/mmIEC 60754-2

Source: Lloyd’s Register – Type Approval Test Specifications

EspañolAprobación de Tipo Lloyd’s Register para Cables

La Aprobación de Tipo de Lloyd’s Register proporciona confianza de que los vendedores y proveedores seleccionados son capaces de proporcionar el estándar requerido de componentes de productos. Para cables, la Aprobación de Tipo LR garantiza que los productos cumplan con las rigurosas demandas de los entornos marinos y offshore. Las especificaciones de prueba detallan las pruebas de rendimiento y ambientales para productos eléctricos en aplicaciones marinas, incluyendo resistencia del conductor, resistencia de aislamiento, prueba de voltaje, rendimiento al fuego, densidad de humo y contenido de halógenos.

繁體中文勞氏船級社電纜型式認證

勞氏船級社型式認證提供信心,確保選定的供應商能夠提供項目所需的產品組件標準。對於電纜,LR型式認證確保產品通過獨立第三方測試和認證滿足海洋和離岸環境的嚴格要求。測試規範詳細說明了海洋應用中電氣產品的性能和環境測試,包括導體電阻、絕緣電阻、電壓測試、防火性能、煙霧密度和鹵素含量。認證過程確保電纜符合IEC、BS和NEK等國際標準。

3. Lloyd’s Register Approved Cable Types

Cables with Lloyd’s Register Shipping Type Approval are manufactured to meet the stringent requirements for marine and offshore applications. These cables are designed for fixed wiring installations across all areas onboard ships and offshore units, including accommodation areas, machinery spaces, and open deck installations.

Primary LR Approved Cable Categories

Cable TypeStandardVoltageApplications
BS 6883 Type SW4 Shipwiring Cables
657TQBS 6883 Type SW40.6/1kVPower, control, lighting (unarmoured)
6571TQBS 6883 Type SW40.6/1kVEarth cable (unarmoured)
658TQBS 6883 Type SW40.6/1kVPower, control, lighting (armoured)
BS 7917 Fire Resistant Cables
TCu/MGT/EPR/CS/ZHBS 7917150/250VInstrumentation (collectively screened)
TCu/MGT/EPR/IS/ZHBS 7917150/250VInstrumentation (individually screened)
TCu/MGT/EPR/ZH SW4BS 79170.6/1kVPower and control
NEK 606 Offshore Cables
BFOUNEK 6060.6/1kV, 150/250VFire resistant power & instrumentation
RFOUNEK 6060.6/1kV, 150/250VFlame retardant power & instrumentation
UXNEK 6060.6/1kVEarthing and bonding services

Source: Eland Cables – Lloyd’s Register Cable

BS 6883 Type SW4 Cable Construction

Component657TQ (Unarmoured)658TQ (Armoured)
ConductorTinned annealed stranded copperTinned annealed stranded copper
Conductor ClassClass 2 per IEC 60228Class 2 per IEC 60228
InsulationEPR (Ethylene Propylene Rubber)EPR (Ethylene Propylene Rubber)
BeddingLow smoke zero halogen (LSZH)Low smoke zero halogen (LSZH)
ArmourNoneGalvanised steel wire braid (GSWB)
Outer SheathLSZH SW4 compoundLSZH SW4 compound
Sheath ColourBlackBlack
Temperature Range-40°C to +90°C-40°C to +90°C

Source: Eland Cables – BS 6883 SW4 Marine Cable

SW4 Sheath Type Designation

SW4 cables are ordinary duty cables with enhanced oil resistance and low smoke and gases emissions when subject to fire. The SW designation in BS 6883 indicates the sheath type, where SW4 specifically refers to halogen-free, flame retardant, heat resistant, oil resistant thermoplastic compound (HOFR). This ensures the cable provides superior performance in the demanding marine environment while minimizing the risk to human life and sensitive equipment by limiting smoke, noxious fumes and acid-forming gases in the event of a fire.

EspañolTipos de Cables Aprobados por Lloyd’s Register

Los cables con Aprobación de Tipo Lloyd’s Register incluyen: 657TQ (potencia/control sin armadura), 658TQ (potencia/control con armadura), y 6571TQ (cable de tierra) según BS 6883 Tipo SW4 para cableado de buques. Los cables BS 7917 con barrera de cinta de mica proporcionan resistencia al fuego. Los cables NEK 606 incluyen BFOU (resistente al fuego) y RFOU (retardante de llama) para aplicaciones offshore. Todos los cables SW4 cuentan con aislamiento EPR, conductor de cobre estañado y cubierta LSZH libre de halógenos para rendimiento óptimo en entornos marinos.

繁體中文勞氏認證電纜類型說明

勞氏船級社型式認證電纜包括:657TQ(無鎧裝電力/控制電纜)、658TQ(鎧裝電力/控制電纜)和6571TQ(接地電纜),符合BS 6883 SW4型船舶佈線標準。BS 7917電纜採用雲母帶阻燃層提供耐火性能。NEK 606電纜包括BFOU(耐火)和RFOU(阻燃)用於離岸應用。所有SW4電纜採用EPR絕緣、鍍錫銅導體和LSZH低煙無鹵護套,以在海洋環境中提供最佳性能。

4. BS 6883 & BS 7917 Marine Cable Standards

BS 6883 is the British (and also an international) industry standard for the Offshore Oil and Gas, Ship Building and Marine Industries. BS 7917 covers fire resistant cables with enhanced circuit integrity. Both standards are certified by Lloyd’s Register and DNV in accordance with ISO 9001 and ISO 14001.

BS 6883 Standard Overview

ParameterBS 6883 Specification
Full TitleElastomer insulated cables for fixed wiring in ships and on mobile and fixed offshore units
Voltage Ratings0.6/1kV (power), 150/250V (instrumentation)
Conductor Sizes1.5mm² to 300mm² (power), 0.5mm² to 2.5mm² (instrumentation)
Flame RetardantIEC 60332-1 (single), IEC 60332-3-22 (bundled)
Low SmokeIEC 61034-1/2
Halogen FreeIEC 60754-1/2
Oil ResistanceIEC 60811-403 (SW4 enhanced)
Operating Temperature-40°C to +90°C (flexed)

BS 7917 Fire Resistant Cable Standard

Fire Resistant vs Flame Retardant Marine Cables

Fire Resistant (BS 7917): Contains mica glass tape (MGT) as fire barrier over conductor. Maintains circuit integrity during fire exposure per IEC 60331-21 (≥120 minutes) and IEC 60331-31 (with water spray). Essential for emergency systems, fire alarms, and evacuation lighting.

Flame Retardant (BS 6883): Self-extinguishing construction that limits flame spread per IEC 60332-3-22. Does not maintain circuit function during fire. Suitable for general power distribution and non-critical applications.

FeatureBS 6883 (Flame Retardant)BS 7917 (Fire Resistant)
Fire BarrierNoYes (Mica Glass Tape)
Circuit IntegrityNot maintained≥120 minutes @ 750°C
IEC 60331 ComplianceNoYes (60331-21, 60331-31)
IEC 60332-3-22YesYes
Low Smoke (IEC 61034)YesYes
Halogen FreeYesYes
ApplicationsGeneral power, lighting, controlEmergency systems, critical circuits

Source: Shipboard Cables – BS 6883 & BS 7917 Standards

EspañolNormas BS 6883 y BS 7917 para Cables Marinos

BS 6883 es la norma británica (y también internacional) para las industrias de petróleo y gas offshore, construcción naval y marina. Cubre cables con aislamiento elastomérico para instalación fija. BS 7917 cubre cables resistentes al fuego con cinta de mica como barrera de fuego, manteniendo la integridad del circuito durante al menos 120 minutos a 750°C según IEC 60331. Ambas normas requieren retardancia de llama (IEC 60332), bajo humo (IEC 61034), y construcción libre de halógenos (IEC 60754). Los cables certificados por Lloyd’s Register cumplen con ISO 9001 e ISO 14001.

繁體中文BS 6883和BS 7917海洋電纜標準說明

BS 6883是英國(也是國際)離岸石油天然氣、造船和海洋工業的行業標準,涵蓋用於固定安裝的彈性體絕緣電纜。BS 7917涵蓋耐火電纜,採用雲母帶作為阻燃層,根據IEC 60331在750°C下維持電路完整性至少120分鐘。兩種標準都要求阻燃性(IEC 60332)、低煙(IEC 61034)和無鹵素結構(IEC 60754)。勞氏認證電纜符合ISO 9001和ISO 14001標準。耐火電纜用於緊急系統和關鍵電路,而阻燃電纜用於一般電力分配。

5. BFOU & RFOU Offshore Cables with LR Approval

BFOU (fire resistant) and RFOU (flame retardant) power and instrumentation cables manufactured in accordance with NEK 606 specifications hold approvals and certification from Lloyd’s Register, DNV Det Norske Veritas, and ABS American Bureau of Shipping. These cables are designed for the demanding offshore oil and gas environment.

BFOU vs RFOU Cable Comparison

FeatureBFOURFOU
Full NameFire Resistant, Halogen-Free, MUD ResistantFlame Retardant, Halogen-Free, MUD Resistant
Fire BarrierMica Glass Tape (MGT)None
ConstructionMGT/EPR/EPR/TCWB/EVAEPR/EPR/TCWB/EVA
Fire TestIEC 60331-21/31 (≥830°C)Not applicable
Flame TestIEC 60332-3-22IEC 60332-3-22
MUD ResistantSHF2 MUDSHF2 MUD
ApplicationsEmergency systems, critical circuitsGeneral power, control, lighting
LR ApprovedYesYes

Source: Eland Cables – BFOU & RFOU Cables

NEK 606 Cable Product Designations

Product CodeTypeVoltageApplication
Power Cables
P1/P8RFOU Power0.6/1(1.2)kVGeneral power distribution
P5/P12BFOU Power0.6/1(1.2)kVEmergency power, critical systems
P3TFOU Power (XLPE)6/10(12)kVMedium voltage distribution
Instrumentation Cables
S1/S5 RFOU(i)RFOU Individual Screen150/250VProcess instrumentation
S2/S6 RFOU(c)RFOU Collective Screen150/250VControl signals
S3/S7 BFOU(i)BFOU Individual Screen150/250VEmergency instrumentation
S4/S8 BFOU(c)BFOU Collective Screen150/250VEmergency control signals
Earth Cables
P15 UXEarth/Bonding Cable0.6/1kVEarthing, bonding, lightning protection

Source: Eland Cables – NEK 606 Standard

EspañolCables Offshore BFOU y RFOU con Aprobación LR

Los cables BFOU (resistentes al fuego) y RFOU (retardantes de llama) fabricados según las especificaciones NEK 606 tienen aprobaciones de Lloyd’s Register, DNV y ABS. BFOU contiene cinta de mica como barrera de fuego y mantiene la integridad del circuito a 830°C durante al menos 90 minutos. RFOU es autoextinguible pero no mantiene la función del circuito durante el fuego. Ambos tipos son resistentes a MUD (lodos de perforación) con cubierta SHF2. Los códigos de producto incluyen P1/P8 (potencia RFOU), P5/P12 (potencia BFOU), S1-S8 (instrumentación con pantalla individual o colectiva).

繁體中文BFOU和RFOU離岸電纜(LR認證)

按照NEK 606規範製造的BFOU(耐火)和RFOU(阻燃)電纜獲得勞氏船級社、DNV和ABS的認證。BFOU含有雲母帶作為阻燃層,在830°C下維持電路完整性至少90分鐘。RFOU是自熄型但在火災期間不維持電路功能。兩種類型都採用SHF2護套具有抗MUD(鑽井泥漿)性能。產品代碼包括P1/P8(RFOU電力)、P5/P12(BFOU電力)、S1-S8(帶獨立或集體屏蔽的儀表電纜)。所有電纜都經過IEC 60332-3-22阻燃測試和IEC 61034低煙測試。

6. Technical Specifications for LR Approved Cables

Electrical Parameters

Conductor Size (mm²)Max. DC Resistance @ 20°C (Ω/km)Current Rating – Free Air (A)Current Rating – Enclosed (A)
1.512.11814
2.57.412519
44.613325
63.084332
101.835944
161.157959
250.72710477
350.52412996
500.387159117
700.268200149
950.193245180
1200.153284208
1500.124330236
1850.0991380272
2400.0754450320
3000.0601520367

Temperature and Environmental Ratings

Continuous Operating Temperature

90°C
EPR insulated cables

Emergency Overload

130°C
Maximum 36 hours

Short Circuit Temperature

250°C
Maximum 5 seconds

Minimum Installation Temp

-20°C
Without preheating

Flexing Temperature Range

-40°C to +90°C
For flexible installation

Minimum Bending Radius

6× OD
During installation

Fire Performance Test Standards

Test StandardTest DescriptionPass Criteria
IEC 60332-1-2Single cable vertical flame testSelf-extinguish, char ≥50mm from top
IEC 60332-3-22Bundled cable flame test (Cat A)Char height ≤2.5m, 7 L/m non-metallic
IEC 60331-21Fire resistance (flame only)Circuit integrity ≥120 min @ 750°C
IEC 60331-31Fire resistance with water spray90 min fire + 15 min water spray
IEC 61034-1/2Smoke density (3m cube test)≥60% light transmittance
IEC 60754-1Halogen acid gas emission≤0.5% HCl equivalent
IEC 60754-2Acidity and conductivitypH ≥4.3, conductivity ≤10 µS/mm

EspañolEspecificaciones Técnicas para Cables Aprobados LR

Los cables aprobados por Lloyd’s Register tienen rangos de temperatura de operación de hasta 90°C continuo, 130°C en emergencia (36 horas), y 250°C en cortocircuito (5 segundos). El rango de flexión es de -40°C a +90°C. Los tamaños de conductor van desde 1.5mm² hasta 300mm² con resistencias DC de 12.1 a 0.0601 Ω/km. Las pruebas de fuego incluyen IEC 60332-1-2 (cable individual), IEC 60332-3-22 (cables agrupados), IEC 60331-21/31 (resistencia al fuego), IEC 61034 (densidad de humo) e IEC 60754 (contenido de halógenos).

繁體中文LR認證電纜技術規格

勞氏認證電纜的運行溫度範圍為連續90°C、緊急130°C(36小時)和短路250°C(5秒)。彎曲溫度範圍為-40°C至+90°C。導體尺寸從1.5mm²到300mm²,直流電阻為12.1至0.0601 Ω/km。防火測試包括IEC 60332-1-2(單根電纜)、IEC 60332-3-22(成束電纜)、IEC 60331-21/31(耐火)、IEC 61034(煙霧密度)和IEC 60754(鹵素含量)。最小彎曲半徑為外徑的6倍。

7. Classification Societies Comparison

Lloyd’s Register is one of several major classification societies that certify marine and offshore cables. Understanding the differences between these organisations helps in selecting the appropriate certification for specific market requirements.

Classification SocietyFoundedHeadquartersIACS Member
Lloyd’s Register (LR)1760London, UKYes
DNV (Det Norske Veritas)1864Høvik, NorwayYes
Bureau Veritas (BV)1828Paris, FranceYes
American Bureau of Shipping (ABS)1862Houston, USAYes
ClassNK (Nippon Kaiji Kyokai)1899Tokyo, JapanYes
China Classification Society (CCS)1956Beijing, ChinaYes
Korean Register (KR)1960Busan, KoreaYes
RINA (Registro Italiano Navale)1861Genoa, ItalyYes

Source: Classification Societies History

IACS – International Association of Classification Societies

The International Association of Classification Societies (IACS) was founded in 1968, and IACS members classify around 90% of the world’s gross tonnage. In 2006, IACS agreed on common shipbuilding rules which came into force for all member societies. Lloyd’s Register was a founding member and remains one of the most recognised classification societies worldwide, with the “A1 at Lloyd’s” rating becoming synonymous with the highest quality standards.

8. Applications for Lloyd’s Register Approved Cables

🚢 Commercial Vessels

Cargo ships, container vessels, tankers, bulk carriers, cruise ships, ferries. Power distribution, lighting, navigation, communication systems.

⚓ Naval Vessels

Warships, submarines, patrol boats, coast guard vessels. Critical systems, weapons control, radar and sonar equipment.

🛢️ Offshore Platforms

Drilling rigs, FPSO vessels, jackup rigs, fixed platforms. Process control, instrumentation, emergency systems.

🔥 Emergency Systems

Fire detection and alarm, emergency lighting, PA/GA systems, smoke extraction, ESD systems, fire pumps.

🔌 Power Distribution

Main switchboards, motor control centres, distribution panels, lighting circuits, HVAC systems, galley equipment.

📡 Communication

Navigation equipment, radio communication, satellite systems, intercom, CCTV, data networks.

9. Feichun Cable LR Compliant Products

Anhui Feichun Special Cable Co., Ltd. (安徽飞纯特种电缆有限公司) manufactures a comprehensive range of marine and offshore cables compliant with Lloyd’s Register Type Approval requirements. Our products are designed and tested in accordance with BS 6883, BS 7917, NEK 606, and IEC 60092 standards.

Product CategoryStandardsCertificationsApplications
SW4 Shipwiring CablesBS 6883, IEC 60092LR, DNV, ABS, BV, CCSPower, control, lighting on ships
Fire Resistant CablesBS 7917, IEC 60331LR, DNV, ABSEmergency systems, critical circuits
BFOU/RFOU Offshore CablesNEK 606, IEC 60092LR, DNV, ABSOffshore platforms, drilling rigs
Marine InstrumentationBS 6883, IEC 60092-376LR, DNV, CCSProcess control, signals
Armoured Power CablesBS 6883, IEC 60502LR, DNV, ABS, BVMechanical protection areas

Authoritative External References

The technical information in this article is supported by the following authoritative sources from Lloyd’s Register, industry publications, and recognized technical resources.

●
Lloyd’s Register Official – Our History
https://www.lr.org/en/about-us/who-we-are/our-history/
Official Lloyd’s Register history since 1760
●
●
Lloyd’s Register – Type Approval Test Specifications
https://www.lr.org/en/knowledge/lloyds-register-rules/type-approval-test-specifications2/type-approval-test-specifications/
Technical test specifications for cables
●
Wikipedia – Lloyd’s Register
https://en.wikipedia.org/wiki/Lloyd’s_Register
Comprehensive LR organization overview
●
Eland Cables – Lloyd’s Register Cable
https://www.elandcables.com/electrical-cable-and-accessories/cables-by-standard/lloyd-s-register-cable
LR approved cable types and applications
●
Eland Cables – BS 6883 SW4 Marine Cable
https://www.elandcables.com/cables/bs-6883-sw4-marine-power-lighting-control-cable
657TQ and 658TQ cable specifications
●
Eland Cables – BFOU & RFOU Cables
https://www.elandcables.com/cables/bfou-and-rfou-cables
NEK 606 offshore cable specifications
●
Eland Cables – NEK 606 Standard
https://www.elandcables.com/electrical-cable-and-accessories/cables-by-standard/nek-606-cable
NEK 606 cable code designations
●
Eland Cables – BS 6883 Standard
https://www.elandcables.com/electrical-cable-and-accessories/cables-by-standard/bs-6883-cable
BS 6883 shipwiring cable standard
●
Shipboard Cables – BS 6883 & BS 7917
http://www.shipboard-cables.com/BS%206883&BS7917/BS%206883%20index.html
Marine cable standards comparison
●
Maritime Cyprus – Lloyd’s Register History
https://maritimecyprus.com/2022/02/23/maritime-history-lloyds-register-it-all-started-with-a-cup-of-coffee/
Historical development of Lloyd’s Register
●
Lloyd’s Register Foundation – Our History
https://www.lrfoundation.org.uk/about-us/our-history
LR Foundation heritage and archives

Contact Feichun Cable

For technical support with Lloyd’s Register approved marine and offshore cable requirements, please contact our engineering team.

📱
📧

Technical Support

[email protected]
👤

Sales – Mr. Zihao Yang

[email protected]
👤

Sales – Mr. Ziyu Huang

[email protected]

Company Address: Building A, Private Science and Technology Park, Hefei Economic and Technological Development Zone, Anhui Province, China

Anhui Feichun Special Cable Co., Ltd. | 安徽飞纯特种电缆有限公司

Professional Manufacturer of Lloyd’s Register Approved Marine & Offshore Cables

© 2025 Feichun Cable. All rights reserved. | Technical content compiled from authoritative industry sources.

Previous Article

What is IEC Cable?

Next Article

What is OGUK / UKOOA Cable?

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注