🚢 IEC 60092 🇬🇧 BS 6883 🇳🇴 NEK 606 ⚡ Up to 30kV 🔥 Fire Resistant 🛢️ MUD Resistant

1. Introduction to IEC 60092 Standard

IEC 60092 is the international standard for electrical installations in ships and fixed/mobile marine applications. Ship wiring is covered by various national standards such as BS 6883 (British) and NEK 606 (Norwegian), and subject to third-party accreditations including Lloyd’s Register, DNV (Det Norske Veritas), and ABS (American Bureau of Shipping). As an international standard, IEC 60092 covers power and instrumentation cables for use on ships and in mobile marine environments.

IEC 60092 cables are specifically designed for electrical installations in ships and offshore environments. These cables meet international standards, ensuring reliable power, control, and signal transmission in fixed and mobile marine applications. With robust construction and exceptional performance, IEC 60092 cables are the trusted choice for demanding marine and offshore projects.

📋 IEC 60092 Standard Family Overview
IEC 60092-350General construction and test methods for power, control, and instrumentation cables up to 18/30(36)kV
IEC 60092-352Selection and installation of cables in fixed electrical systems up to 15kV on ships
IEC 60092-353Non-radial power cables with extruded solid insulation for 1kV and 3kV (including fire resistant)
IEC 60092-354Single and three-core power cables with conductor/core screening for 6kV to 30kV
IEC 60092-360Electrical, mechanical characteristics of insulation and sheathing materials
IEC 60092-376Screened and unscreened cables for control and instrumentation circuits 150/250V

Source: Eland Cables – IEC 60092 Standard Cable

EspañolIntroducción al Estándar IEC 60092

IEC 60092 es la norma internacional para instalaciones eléctricas en buques y aplicaciones marinas fijas/móviles. El cableado de buques está cubierto por varias normas nacionales como BS 6883 (británica) y NEK 606 (noruega), y está sujeto a acreditaciones de terceros incluyendo Lloyd’s Register, DNV y ABS. La familia de normas IEC 60092 incluye IEC 60092-350 (requisitos generales de construcción), IEC 60092-353 (cables de potencia 1kV/3kV), IEC 60092-354 (cables de potencia 6kV-30kV), e IEC 60092-376 (cables de instrumentación 150/250V). Estos cables están diseñados específicamente para resistir ambientes marinos severos incluyendo vibración, movimiento y exposición a aceites.

繁體中文IEC 60092 標準簡介

IEC 60092是船舶和固定/移動海洋應用電氣裝置的國際標準。船舶佈線由各種國家標準覆蓋,如BS 6883(英國)和NEK 606(挪威),並受Lloyd’s Register、DNV和ABS等第三方認證機構的認證。IEC 60092標準系列包括:IEC 60092-350(通用結構要求和測試方法,電壓至18/30kV)、IEC 60092-352(電纜選擇和安裝)、IEC 60092-353(1kV和3kV擠壓絕緣電力電纜,包括耐火電纜)、IEC 60092-354(6kV至30kV中高壓電力電纜)、IEC 60092-360(絕緣和護套材料特性)、IEC 60092-376(150/250V控制和儀表電纜)。這些電纜專門設計用於承受嚴苛的海洋環境,包括振動、運動和油類暴露。

2. Related Standards Comparison

IEC 60092 cables are complemented by national standards that provide additional specifications for marine and offshore applications. The main related standards are BS 6883 (British Standard for offshore), NEK 606 (Norwegian offshore standard), and BS 7917 (fire resistant cables).

StandardOriginScopeKey FeaturesCertifications
International Standards
IEC 60092International (IEC)Ships & offshore unitsPower, control, instrumentation up to 30kVDNV, Lloyd’s, ABS
British Standards
BS 6883UK (BSI)Fixed offshore units, shipsEPR insulation, SW4 sheath, HOFRLloyd’s Register
BS 7917UK (BSI)Fire resistant cablesMica tape fire barrier, 120min at 750°CLloyd’s, DNV
Norwegian Standard
NEK TS 606Norway (NEK)Offshore oil & gasMUD resistant, halogen-free, BFOU/RFOUDNV, Lloyd’s, ABS

Source: Batt Cables – IEC 60092 Cable

3. BS 6883 Type SW4 Marine Cables

BS 6883 is the British (and international) industry standard for the Offshore Oil and Gas, Ship Building and Marine Industries. These cables feature tinned annealed copper conductors complying with BS 6360/IEC 60228, EPR insulation complying with BS 7655, and HOFR (Heat and Oil Resistant and Flame Retardant) halogen-free sheathing.

🔥 BS 6883 SW4 Cable Characteristics
StandardBS 6883 (Lloyd’s Register Approved)
Voltage Rating0.6/1kV (power), 150/250V (instrumentation)
ConductorTinned annealed copper, Class 2 or Class 5 per EN 60228
InsulationHalogen-free EPR (Ethylene Propylene Rubber)
Sheath TypeSW4 — HOFR halogen-free, flame retardant, heat/oil resistant
Temperature Range-40°C to +90°C (fixed), -25°C to +90°C (flexed)
Fire PerformanceFlame retardant IEC 60332-3-22, Low smoke IEC 61034

3.1 BS 6883 Cable Model Comparison

ModelTypeVoltageArmourApplicationFire Performance
657TQSW4 Power0.6/1kVUnarmouredPower, control, lightingFlame Retardant
658TQSW4 Power0.6/1kVGSWB ArmouredPower, control (mechanical protection)Flame Retardant
6571TQSW4 Earth0.6/1kVUnarmouredEarth/protective conductorFlame Retardant

Source: Eland Cables – BS 6883 SW4 Marine Cable

4. NEK TS 606 Offshore Cables (BFOU & RFOU)

NEK TS 606 is the Norwegian offshore industry technical specification covering a range of power, instrumentation and earth cables that are halogen-free and/or MUD resistant. The NEK 606 cable standard has been widely adopted internationally with BFOU (fire resistant) and RFOU (flame retardant) cables in common use for offshore oil and gas applications.

⚡ NEK 606 Cable Code Designation

BFire resistant insulation (with mica glass tape) — maintains circuit integrity during fire
R / TFlame retardant insulation — EPR (R) or XLPE (T)
FInner sheath/bedding present
OWire braid armour (tinned copper wire braid TCWB)
UOuter sheath (halogen-free, MUD resistant)
(i)Individual screen — each pair separately screened
(c)Collective screen — single screen over all pairs

4.1 NEK 606 Power Cable Models

ModelCodeVoltage (U₀/U)TypeFire PerformanceApplication
Low Voltage Power Cables (0.6/1kV)
RFOU P101P1010.6/1kVFlame RetardantIEC 60332-3-22General power distribution
BFOU P105P1050.6/1kVFire ResistantIEC 60331Emergency systems, critical circuits
UX P108P1080.6/1kVEarth CableIEC 60332-1Earth/protective conductor
Medium Voltage Power Cables (3.6kV – 18/30kV)
RFOU P102P1023.6/6kVFlame RetardantIEC 60332-3-22MV power distribution
RFOU P103P1036/10kVFlame RetardantIEC 60332-3-22MV power distribution
RFOU P104P1048.7/15kVFlame RetardantIEC 60332-3-22MV power distribution
RFOU P112P11212/20kVFlame RetardantIEC 60332-3-22HV power distribution
RFOU P113P11318/30kVFlame RetardantIEC 60332-3-22HV power distribution

4.2 NEK 606 Instrumentation Cable Models

ModelCodeVoltageScreenFire PerformanceApplication
Instrumentation Cables (150/250V)
RFOU(i) S101S101150/250VIndividualFlame RetardantAnalog signals 4-20mA
RFOU(c) S102S102150/250VCollectiveFlame RetardantDigital signals
BFOU(i) S103S103150/250VIndividualFire ResistantEmergency instrumentation
BFOU(c) S104S104150/250VCollectiveFire ResistantEmergency control circuits

Source: Eland Cables – NEK 606 Standard Cable

5. IEC 60092 Series Cable Models

IEC 60092-353 covers power cables for 1kV and 3kV, while IEC 60092-354 covers medium to high voltage cables from 6kV to 30kV. IEC 60092-376 specifies control and instrumentation cables at 150/250V.

5.1 IEC 60092-353 Power Cables (0.6/1kV – 1.8/3kV)

ModelStandardVoltageArmourFire PerformanceApplication
XI 0.6/1kVIEC 60092-3530.6/1kVUnarmouredFlame RetardantPower distribution
XAI 0.6/1kVIEC 60092-3530.6/1kVArmouredFlame RetardantMechanical protection areas
XAI 331 0.6/1kVIEC 60092-3530.6/1kVArmoured + Fire BarrierFire ResistantEmergency circuits

5.2 IEC 60092-354 Medium/High Voltage Power Cables

ModelStandardVoltage (U₀/U)Um (kV)ConstructionApplication
XAI 3.6/6kVIEC 60092-3543.6/6kV7.2Conductor + core screen, armouredMV power
XAI 6/10kVIEC 60092-3546/10kV12Conductor + core screen, armouredMV power
XAI 8.7/15kVIEC 60092-3548.7/15kV17.5Conductor + core screen, armouredMV power
XAI 12/20kVIEC 60092-35412/20kV24Conductor + core screen, armouredHV power
XAI 18/30kVIEC 60092-35418/30kV36Conductor + core screen, armouredHV power

5.3 IEC 60092-376 Instrumentation Cables (150/250V)

ModelVoltageScreenArmourFire PerformanceApplication
XI(i) 150/250V150/250VIndividualUnarmouredFlame RetardantInstrumentation
XI(c) 150/250V150/250VCollectiveUnarmouredFlame RetardantControl circuits
XAI(i) 150/250V150/250VIndividualArmouredFlame RetardantInstrumentation (protected)
XAI(c) 150/250V150/250VCollectiveArmouredFlame RetardantControl (protected)
XAI(i) 331 150/250V150/250VIndividualArmoured + MicaFire ResistantEmergency instrumentation
XAI(c) 331 150/250V150/250VCollectiveArmoured + MicaFire ResistantEmergency control

Source: GlobalSpec – IEC 60092-353

6. BS 7917 Fire Resistant Cables

BS 7917 covers fire resistant cables with enhanced circuit integrity. These cables use mica glass tape (MGT) as a fire barrier over the conductor, enabling the cable to maintain circuit integrity for at least 120 minutes at 750°C according to IEC 60331.

ModelVoltageScreenArmourFire RatingApplication
TCu/MGT/EPR/IS/ZH/GSWB/ZH150/250VIndividualGSWB120min @ 750°CEmergency instrumentation
TCu/MGT/EPR/CS/ZH/GSWB/ZH150/250VCollectiveGSWB120min @ 750°CEmergency control
TCu/MGT/EPR/ZH/GSWB/ZH SW40.6/1kV—GSWB120min @ 750°CEmergency power

Construction Key: TCu = Tinned Copper, MGT = Mica Glass Tape fire barrier, EPR = Ethylene Propylene Rubber insulation, IS = Individual Screen, CS = Collective Screen, ZH = Zero Halogen sheath, GSWB = Galvanized Steel Wire Braid armour.

7. Fire Performance Comparison

🔥 BFOU vs RFOU — Critical Selection Criteria
PropertyBFOU (Fire Resistant)RFOU (Flame Retardant)
Fire BarrierMica glass tape (MGT)None
Circuit IntegrityMaintained during fire (2-3 hours)NOT maintained during fire
Test StandardIEC 60331-21IEC 60332-3-22
Fire Temperature750-830°C sustainedSelf-extinguishing only
ApplicationEmergency systems, fire alarms, evacuationGeneral power, non-critical circuits
CostHigher (mica tape layer)Standard

⚠️ Emergency systems, fire detection, emergency lighting, and life safety circuits MUST use fire resistant (BFOU) cables!

Source: Eland Cables – BFOU & RFOU Cables

8. Complete Cable Model Summary

StandardModelVoltageTypeArmourFire
BS 6883 Type SW4
BS 6883657TQ0.6/1kVPowerNoFR
BS 6883658TQ0.6/1kVPowerGSWBFR
BS 68836571TQ0.6/1kVEarthNoFR
NEK 606 Power Cables
NEK 606RFOU P1010.6/1kVPowerTCWBFR
NEK 606BFOU P1050.6/1kVPowerTCWBFire Res
NEK 606UX P1080.6/1kVEarthNoFR
NEK 606RFOU P1023.6/6kVPowerTCWBFR
NEK 606RFOU P1036/10kVPowerTCWBFR
NEK 606RFOU P1048.7/15kVPowerTCWBFR
NEK 606RFOU P11212/20kVPowerTCWBFR
NEK 606RFOU P11318/30kVPowerTCWBFR
NEK 606 Instrumentation Cables
NEK 606RFOU(i) S101150/250VInst (i)TCWBFR
NEK 606RFOU(c) S102150/250VInst (c)TCWBFR
NEK 606BFOU(i) S103150/250VInst (i)TCWBFire Res
NEK 606BFOU(c) S104150/250VInst (c)TCWBFire Res
IEC 60092-353 Power Cables
IEC 60092-353XI 0.6/1kV0.6/1kVPowerNoFR
IEC 60092-353XAI 0.6/1kV0.6/1kVPowerYesFR
IEC 60092-353XAI 331 0.6/1kV0.6/1kVPowerYes+MGTFire Res
IEC 60092-354 MV/HV Power Cables
IEC 60092-354XAI 3.6/6kV3.6/6kVPowerYesFR
IEC 60092-354XAI 6/10kV6/10kVPowerYesFR
IEC 60092-354XAI 8.7/15kV8.7/15kVPowerYesFR
IEC 60092-354XAI 12/20kV12/20kVPowerYesFR
IEC 60092-354XAI 18/30kV18/30kVPowerYesFR
IEC 60092-376 Instrumentation Cables
IEC 60092-376XI(i) 150/250V150/250VInst (i)NoFR
IEC 60092-376XI(c) 150/250V150/250VInst (c)NoFR
IEC 60092-376XAI(i) 150/250V150/250VInst (i)YesFR
IEC 60092-376XAI(c) 150/250V150/250VInst (c)YesFR
IEC 60092-376XAI(i) 331150/250VInst (i)Yes+MGTFire Res
IEC 60092-376XAI(c) 331150/250VInst (c)Yes+MGTFire Res

Legend: FR = Flame Retardant (IEC 60332), Fire Res = Fire Resistant (IEC 60331), (i) = Individual screen, (c) = Collective screen, GSWB = Galvanized Steel Wire Braid, TCWB = Tinned Copper Wire Braid, MGT = Mica Glass Tape

9. Key Technical Parameters

Voltage Range

150V – 30kV
U₀/U rating

Conductor

Tinned Cu
Class 2/5 EN 60228

Temp Range

-40°C to +90°C
Operating

Fire Test

750°C
IEC 60331

Insulation

EPR / XLPE
Halogen-free

Sheath

LSZH / HOFR
MUD resistant

Authoritative External References

●
Eland Cables – IEC 60092 Standard Cable
https://www.elandcables.com/…/iec60092-cable
●
Eland Cables – NEK 606 Standard Cable
https://www.elandcables.com/…/nek-606-cable
●
Eland Cables – BFOU & RFOU Cables
https://www.elandcables.com/cables/bfou-and-rfou-cables
●
Eland Cables – BS 6883 SW4 Marine Cable
https://www.elandcables.com/…/bs-6883-sw4
●
●
●
IEC Webstore – IEC 60092-353:2024
https://webstore.iec.ch/…/72868
●
Batt Cables – IEC 60092 Cable
https://battcables.com/…/iec-60092-cable
●
Habia – BFOU and RFOU Cables NEK TS 606
https://www.habia.com/…/bfou-and-rfou-cables
●
Prysmian/Draka – NEK606 Products
https://nl.prysmian.com/…/nek606

Contact Feichun Cable

For technical support with IEC 60092 marine cables, NEK 606 offshore cables, BS 6883 shipwiring, or BFOU/RFOU applications, please contact our engineering team.

📱
📧

Technical Support

[email protected]
👤

Sales – Mr. Zihao Yang

[email protected]
👤

Sales – Mr. Ziyu Huang

[email protected]

Anhui Feichun Special Cable Co., Ltd. | 安徽飞纯特种电缆有限公司

Professional Manufacturer of IEC 60092, NEK 606 & BS 6883 Marine & Offshore Cables

© 2025 Feichun Cable. All rights reserved.

Previous Article

What is IEC 60228 Cable?

Next Article

What is IEC 61158 Cable?

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注