What is DLO TORSIONFLEX RHH/RHW-2 2000V Wind Turbine Cable?

Comprehensive Technical Guide to UL/CSA Listed Portable Power Cables for Wind Energy Applications — Based on GE Specification 104W7006 with Full Multi-Standard Compliance

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
DLO TORSIONFLEX RHH/RHW-2 2000V Wind Turbine Cable | UL 44 | GE 104W7006 | Anhui Feichun Special Cable

What is DLO TORSIONFLEX RHH/RHW-2 2000V Wind Turbine Cable?

Comprehensive Technical Guide to UL/CSA Listed Portable Power Cables for Wind Energy Applications — Based on GE Specification 104W7006 with Full Multi-Standard Compliance

UL 44 UL 1685 IEEE-1202 CSA C22.2 No. 38 CSA C22.2 No. 230 ASTM B-3 GE Spec 104W7006

1. Introduction to DLO TORSIONFLEX Technology

The DLO TORSIONFLEX RHH/RHW-2 represents an advanced category of portable power cables specifically engineered for demanding industrial applications, including wind turbine installations where torsional flexibility and multi-environment performance are critical requirements. This cable type combines the proven durability of Diesel Locomotive (DLO) construction with enhanced torsion resistance, making it uniquely suited for wind energy systems where cables must accommodate continuous nacelle rotation while maintaining electrical integrity.

Cable Designation Analysis: DLO (Diesel Locomotive Origin) + TORSIONFLEX (Enhanced Torsion Resistance 92°/m) + RHH (Rubber High Heat 90°C Dry) / RHW-2 (Rubber Heat & Water Resistant 90°C Wet/Dry) + 2000V (Maximum Voltage Rating) + RW90/RW90-TC (CSA Canadian Rating 1000V)

Originally developed for railroad applications where extreme flexibility and durability were paramount, DLO technology has evolved to address modern industrial challenges. According to industry analysis, while earlier wind turbine designs utilized common cables like standard DLO, welding cable, or RHH/RHW configurations, wind applications demanded enhanced characteristics including strong torsional and bending flexibility combined with resistance to electromagnetic interference, extreme temperatures, UV radiation, chemicals, oils, and even salt spray in coastal applications.

Reference: Wind Energy Cable Standards Evolution — Allied Wire & Cable

2. Multi-Standard Compliance Framework

2.1 Primary North American Standards

The DLO TORSIONFLEX achieves comprehensive certification across multiple regulatory frameworks, enabling deployment across diverse jurisdictions and applications. This multi-standard approach ensures maximum flexibility for system integrators and end users.

UL
Underwriters Laboratories
Listed as Type RHH/RHW-2 per UL 44 for thermoset-insulated wires and cables. Rated 90°C wet and dry with VW-1 flame rating.
UL: E193954 (CPE jacket)
CSA
Canadian Standards Association
Listed as Type RW90 EP 1kV per CSA C22.2 No. 38 and C22.2 No. 230. FT1 and FT4 flame tested at -40°C.
CSA: 1101269, LL 103932:205591
MSHA
Mine Safety & Health Admin
Approved for underground mining applications. Meets flame test requirements for hazardous mining environments.
MSHA Approved
IEEE
IEEE 1202 / UL 1685
Limited Smoke (LS) ST1 rating per UL 1685 vertical tray fire propagation test. FT4 flame rating for sizes 1/0 AWG and larger.
IEEE-1202 / ST1 Compliant

2.2 GE Specification 104W7006 Compliance

The cable is engineered to meet the requirements of General Electric Specification 104W7006, which establishes stringent performance criteria for cables used in wind turbine applications. This specification addresses critical parameters including torsion cycles, temperature cycling, and mechanical stress resistance specific to wind energy environments.

Voltage Rating (RHH/RHW-2)
600V / 2000V
Dual-rated per UL 44 standard
Voltage Rating (CSA RW90)
1000V
Canadian rating per C22.2 No. 38
Torsion Resistance
92°/m
TORSIONFLEX enhanced specification
Operating Temperature
90°C
Wet and dry locations per UL/CSA

Reference: UL & CSA Listed 2kV HDFPC-DLO Standards — JYC Cable

2.3 Voltage Rating Comparison

600V RHH/RHW-2
1000V CSA RW90
2000V DLO Maximum

3. Construction Specifications

3.1 Conductor Design

The conductor comprises annealed flexible stranded bare copper conforming to ASTM B-3 (Standard Specification for Soft or Annealed Copper Wire). This specialized stranding pattern achieves optimal flexibility for portable power applications while maintaining excellent electrical conductivity. The fine-stranded construction enables repeated flexing without conductor fatigue.

Conductor Specifications

Material: Annealed flexible stranded bare copper

Standard: ASTM B-3

Configuration: Multiple strand counts from 19×0.373mm (14 AWG) to 1591×0.511mm (646 MCM)

Flexibility Class: Extra-flexible for portable power applications

Separator Layer

Material: White polyester tape

Application: Longitudinally applied between conductor and insulation

Function: Prevents insulation compound migration and facilitates stripping during termination

3.2 Insulation System

The cable utilizes Ethylene-Propylene Rubber (HEPR/EPR) insulation meeting UL, CSA, and ICEA requirements for 90°C operation. This thermoset rubber compound provides superior electrical properties with a minimum tensile strength of 1000 psi, ensuring long-term reliability in demanding wind turbine environments.

3.3 Outer Jacket Construction

A heavy-duty CPE (Chlorinated Polyethylene) thermosetting compound jacket provides the outer protective layer, engineered to ICEA S-95-658 and NEMA WC-70 specifications with minimum tensile strength of 1400 psi. The jacket formulation delivers comprehensive environmental protection essential for wind turbine service.

  • Ozone, sunlight, and UV radiation resistant
  • Oil, grease, and chemical resistant compound
  • Weather and abrasion resistant outer surface
  • Limited smoke (LS) ST1 rating per UL 1685
  • VW-1 vertical flame test compliant
  • Ink jet printed for easy identification
  • MSHA accepted for underground mining
  • Rated RW90-TC (Tray Cable) for sizes 1/0 AWG and larger

Trailing cables for mobile equipment, such as those used in mining and wind energy applications, must balance electrical performance with mechanical durability. Key considerations include optimized tensile strength, insulation integrity, and minimum bending radius specifications tailored to specific machine applications.

Reference: Trailing Cable Technology Solutions — Reeling Cable

4. Complete Technical Parameters

4.1 Cable Dimensional and Electrical Data (14 AWG to 4 AWG)

Size
(AWG/MCM)
Stranding
(N×mm)
Conductor Ø
(inch / mm)
Insulation
(inch / mm)
Jacket
(inch / mm)
Overall Ø
(min/nom/max inch)
Weight
(lbs/kft / kg/km)
Ampacity
30°C (A)
1419×0.3730.07 / 1.830.045 / 1.140.015 / 0.380.182/0.194/0.20628 / 4135
1019×0.5940.11 / 2.900.045 / 1.140.030 / 0.760.257/0.269/0.28160 / 9055
665×0.5110.19 / 4.720.060 / 1.520.030 / 0.760.351/0.370/0.389126 / 188105
4105×0.5110.240 / 6.100.060 / 1.520.030 / 0.760.420/0.435/0.465192 / 286140

4.2 Cable Dimensional and Electrical Data (1 AWG to 4/0 AWG)

Size
(AWG/MCM)
Stranding
(N×mm)
Conductor Ø
(inch / mm)
Insulation
(inch / mm)
Jacket
(inch / mm)
Overall Ø
(min/nom/max inch)
Weight
(lbs/kft / kg/km)
Ampacity
30°C (A)
1224×0.5110.366 / 9.300.080 / 2.030.045 / 1.140.653/0.668/0.684421 / 628220
1/0273×0.5110.417 / 10.600.080 / 2.030.045 / 1.140.656/0.671/0.725466 / 693260
4/0532×0.5110.590 / 14.900.080 / 2.030.065 / 1.650.827/0.870/0.914872 / 1299405

4.3 Cable Dimensional and Electrical Data (262 MCM to 646 MCM)

Size
(AWG/MCM)
Stranding
(N×mm)
Conductor Ø
(inch / mm)
Insulation
(inch / mm)
Jacket
(inch / mm)
Overall Ø
(min/nom/max inch)
Weight
(lbs/kft / kg/km)
Ampacity
30°C (A)
262646×0.5110.638 / 16.200.090 / 2.280.065 / 1.650.950/0.966/0.9821056 / 1574471
373925×0.5110.772 / 19.600.090 / 2.280.065 / 1.651.086/1.103/1.1201451 / 2162590
4441110×0.5110.835 / 21.200.090 / 2.280.065 / 1.651.149/1.170/1.1941697 / 2528656
5351332×0.5110.929 / 23.600.090 / 2.280.065 / 1.651.244/1.272/1.3002023 / 3015731
6461591×0.5111.020 / 25.900.090 / 2.280.065 / 1.651.280/1.350/1.3902340 / 3488815

5. Performance Specifications

5.1 Temperature Ratings

ParameterRatingConditionStandard Reference
Maximum Conductor Temperature90°CDry locationsUL 44 Type RHH
Maximum Conductor Temperature90°CWet locationsUL 44 Type RHW-2
Emergency Overload Temperature130°CShort-term operationICEA S-95-658
Short Circuit Temperature250°CFault conditionsICEA S-95-658
Minimum Installation Temperature-40°CCold bend testCSA C22.2 No. 38

5.2 Mechanical Performance

Minimum Bending Radius
8×D
D = Overall cable diameter
Insulation Tensile Strength
≥1000 psi
HEPR insulation minimum
Jacket Tensile Strength
≥1400 psi
CPE jacket minimum
Torsion Resistance
92°/m
TORSIONFLEX specification

5.3 Flame and Safety Ratings Summary

RatingStandardApplicability
VW-1ULAll sizes, black jacket
FT1CSAAll sizes
FT4CSA / IEEE 12021/0 AWG and larger (UL), #8 and larger (CSA)
ST1 Limited SmokeUL 16851/0 AWG and larger, black jacket
SUN RES (Sunlight Resistant)UL / CSAAll sizes, black jacket
Oil ResistantCSAAll sizes
FOR CT USE (Cable Tray)UL1/0 AWG and larger, black jacket
Tray Cable (TC) RW90-TCCSA1/0 AWG and larger

Reference: DLO Cable Technical Specifications — Nassau National Cable

6. Applications and Use Cases

6.1 Primary Application: Wind Turbine Systems

The DLO TORSIONFLEX is engineered specifically for wind turbine power and control tray cable applications. The 92°/m torsion resistance specification addresses the continuous rotational stresses encountered as wind turbine nacelles track wind direction changes. The cable’s GE 104W7006 compliance ensures compatibility with major turbine OEM requirements.

Wind Turbine Suitability: Designed for uses requiring flexible power cables in both portable and fixed installations within wind energy systems. The cable accommodates the unique demands of tower-to-nacelle power distribution where continuous rotation and environmental exposure are primary considerations.

6.2 Extended Industrial Applications

The DLO construction, characterized by a combination of flexibility and toughness, makes it a sought-after solution for power supply in demanding environments beyond wind energy. Industry experts note that DLO cable finds application in wind turbines, drill rigs, earth moving equipment, and mining equipment due to its fire-resistant jacket and robust insulation system.

  • Wind turbine nacelle power and control wiring
  • Motor leads for generators and industrial motors
  • Battery connections and jumper cables
  • Deep well submersible pump cable applications
  • Electrically driven earth moving equipment
  • Mining equipment and underground installations (MSHA approved)
  • Drilling rig power distribution
  • Railroad and transit car wiring
  • Shipyard and marine applications
  • Portable and fixed industrial installations

6.3 Installation Environments

The cable is suitable for installation in wet or dry areas, conduit, ducts, trays, or troughs. The RW90-TC (Tray Cable) rating for sizes 1/0 AWG and larger enables cable tray installations without additional protection. The UL Submersible Pump Cable listing extends applicability to submerged pump motor connections.

7. Standards and Specifications Reference

StandardTitle / ScopeApplication
UL 44Thermoset-Insulated Wires and CablesRHH/RHW-2 type designation
UL 1685Vertical-Tray Fire-Propagation and Smoke-Release TestST1 limited smoke rating
IEEE 1202Flame-Propagation Testing of Wire and CableFT4 cable tray flame test
CSA C22.2 No. 38Thermoset-Insulated Wires and CablesRW90 Canadian certification
CSA C22.2 No. 230Tray CablesRW90-TC tray cable rating
ASTM B-3Soft or Annealed Copper WireConductor specification
ICEA S-95-658 / NEMA WC-70Power Cables Rated 2000V or LessConstruction and performance
GE Spec 104W7006Wind Turbine Cable SpecificationOEM compliance

8. Installation Guidelines

8.1 Minimum Bend Radius Considerations

The minimum bend radius of 8× overall diameter must be maintained during both installation and permanent routing. For wind turbine applications, additional service loop provisions should accommodate nacelle rotation without exceeding this limit throughout the operational rotation range.

8.2 Temperature Considerations

Installation may proceed at temperatures as low as -40°C per CSA cold bend test certification. However, care should be exercised when handling cables at extreme low temperatures to prevent potential jacket stiffening issues. Pre-conditioning in heated storage may be advisable for installations below -20°C.

8.3 Standard Packaging

Standard delivery configuration is 1000 meters on wooden drums. Alternative packaging formats including smaller reels, cut-to-length options, and custom drum sizes are available upon request from Anhui Feichun Special Cable Co., Ltd.

Request Technical Specifications or Quotation

Anhui Feichun Special Cable Co., Ltd. (安徽飞纯特种电缆有限公司) provides custom DLO TORSIONFLEX cable solutions engineered to your specific wind energy and industrial project requirements. Our technical team offers application engineering support, cable sizing calculations, and comprehensive documentation packages including UL, CSA, and MSHA certifications.

Previous Article

What is H07ZZ-F WIND 450/750V Wind Turbine Cable?

Next Article

What is NSHXAFÖ 0.6/1 to 3.6/6 kV Wind Turbine Cable?

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注