What is NSHXAFÖ 0.6/1 to 3.6/6 kV Wind Turbine Cable?

Comprehensive Technical Guide to DIN VDE 0250 p.606 Halogen-Free Single Conductor Flexible Power Cables for Wind Energy and Heavy-Duty Industrial Applications

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
NSHXAFÖ 0.6/1 to 3.6/6 kV Halogen Free Wind Turbine Cable | DIN VDE 0250 p.606 | Anhui Feichun Special Cable

What is NSHXAFÖ 0.6/1 to 3.6/6 kV Wind Turbine Cable?

Comprehensive Technical Guide to DIN VDE 0250 p.606 Halogen-Free Single Conductor Flexible Power Cables for Wind Energy and Heavy-Duty Industrial Applications

0.6/1 kV 1.8/3 kV 3.6/6 kV
DIN VDE 0250 p.606 DIN VDE 0207 p.20 DIN VDE 0207 p.24 IEC 60228 Class 5 HD 383

1. Introduction to NSHXAFÖ Cable Technology

The NSHXAFÖ represents a specialized category of single conductor halogen-free flexible power cables engineered for demanding industrial applications, including wind turbine installations where exceptional flexibility, fire safety, and multi-voltage capability are critical requirements. This cable series spans three voltage classes from 0.6/1 kV through 3.6/6 kV, providing comprehensive solutions for both low and medium voltage power distribution within wind energy systems.

Cable Designation Analysis: N (German standard) + SH (Rubber sheathed) + X (Cross-linked/halogen-free insulation) + A (Outer sheath) + F (Fine-wire flexible Class 5) + Ö (Oil resistant) — Single conductor halogen-free flexible power cable with enhanced environmental resistance

The NSHXAFÖ cable construction follows DIN VDE 0250 Part 606, which establishes comprehensive requirements for halogen-free rubber-sheathed cables suitable for both mobile and fixed installations. Germany’s DIN VDE standards have achieved global recognition as the ultimate benchmark for tough rubber-sheathed flexible cables, particularly for applications involving cranes, material handling equipment, and renewable energy installations where reliability is non-negotiable.

Reference: DIN VDE 0250 Cable Standard — Eland Cables

2. Voltage Class Overview

0.6/1 kV
Low Voltage Class
U₀ = 600V | U = 1000V
1.8/3 kV
Medium Voltage Class
U₀ = 1800V | U = 3000V
3.6/6 kV
High Medium Voltage
U₀ = 3600V | U = 6000V

The multi-voltage capability of the NSHXAFÖ series enables system designers to specify a single cable type across various voltage levels within a wind turbine installation. According to VDE 0250 Part 606, arrangements made of single-conductor NSHXAFÖ cables with nominal voltage of at least U₀/U: 1.8/3 kV can be used for short circuit-proof and short-to-ground-proof installation up to 1000 V in accordance with VDE 0100 Part 520 and VDE 0298 Part 3.

Reference: NSHXAFÖ 1.8/3 kV Technical Specifications — LAPP Group

3. Construction Specifications

3.1 Conductor Design

The conductor comprises annealed flexible stranded copper conforming to IEC 60228 and HD 383 Class 5 requirements. Both tin-coated and bare copper configurations are available depending on application requirements. The Class 5 fine-wire stranding achieves optimal flexibility for mobile applications while maintaining excellent electrical conductivity.

Conductor Specifications

Material: Annealed flexible stranded copper

Surface Treatment: Tin-coated or bare

Flexibility Class: Class 5 per IEC 60228/HD 383

Cross-Section Range: 1.5 mm² to 500 mm²

Separator Layer

Application: As needed between conductor and insulation

Material: Suitable tape separator

Function: Prevents compound migration, facilitates stripping during termination

3.2 Insulation System

The cable utilizes Ethylene-Propylene Rubber (EPR) type 3GI3 insulation conforming to DIN VDE 0207 Part 20. This halogen-free rubber compound provides superior electrical properties with excellent thermal stability across the operating temperature range. EPR insulation offers significant advantages over traditional materials, including enhanced flexibility retention and superior resistance to thermal aging.

The flexibility of elastomer insulation proves particularly crucial in wind turbine applications. Nacelles and tower sections are subject to constant motion from wind loading and rotational stresses, creating dynamic conditions that would quickly fatigue rigid insulation materials. The elastomer compound flexes with these movements, maintaining its integrity over thousands of operational cycles without compromising electrical performance.

Reference: EPR Elastomer Insulation Technology — Crane Cable

3.3 Outer Jacket Construction

The outer jacket utilizes halogen-free thermosetting compound type HM3 conforming to DIN VDE 0207 Part 24. Standard jacket color is black, though alternative colors are available upon request for circuit identification purposes.

  • Halogen-free construction protects human life in fire events through low smoke density
  • Eliminates corrosive gas emission during combustion
  • Excellent flexibility for mobile and fixed applications
  • Water resistant compound formulation
  • Flame retardant per IEC 60332-1-2
  • UV, sunlight, and ozone resistant
  • Oil resistant (indicated by “Ö” designation)
  • Ink jet printed for easy circuit identification

4. Temperature Performance

4.1 Operating Temperature Range

-40°C (Fixed) -25°C (Mobile) 0°C +25°C +90°C (Max)
Maximum Operating Temperature
+90°C
Continuous conductor temperature
Minimum (Mobile Installation)
-25°C
Flexible/mobile applications
Minimum (Fixed Installation)
-40°C
Permanently installed cables
Short Circuit Temperature
+250°C
Maximum during fault conditions

5. Detailed Technical Parameters

5.1 NSHXAFÖ 0.6/1 kV — Low Voltage Series

NSHXAFÖ 0.6/1 kV Technical Parameters
Cross-Section
(mm²)
Insulation Thickness
(mm)
Sheath Thickness
(mm)
Overall Diameter
(mm)
Net Weight
(kg/km)
Current Capacity
@ 30°C (A)
1×1.50.80.84.73430
1×2.50.90.85.44841
1×41.00.86.26655
1×61.00.86.78770
1×101.20.88.113598
1×161.20.89.2195132
1×251.40.810.8286176
1×351.41.011.8379218
1×501.61.014.3545276
1×701.61.016.1738347
1×951.81.018.6964416
1×1201.81.019.71194488
1×1502.01.022.01480566
1×1852.21.225.01819644
1×2402.41.226.92339775
1×3002.61.230.92914898
1×4002.81.233.337611060
1×5003.01.438.347371250

5.2 NSHXAFÖ 1.8/3 kV — Medium Voltage Series

NSHXAFÖ 1.8/3 kV Technical Parameters
Cross-Section
(mm²)
Insulation Thickness
(mm)
Sheath Thickness
(mm)
Overall Diameter
(mm)
Net Weight
(kg/km)
Current Capacity
@ 30°C (A)
1×1.51.30.85.74830
1×2.51.30.86.26041
1×41.30.86.87855
1×61.30.87.310070
1×101.50.88.715098
1×161.50.810.1216132
1×251.80.812.3328176
1×351.81.013.3425218
1×501.81.015.0573276
1×701.81.016.8770347
1×952.21.019.71019416
1×1202.21.020.81251488
1×1502.21.023.01547566
1×1852.41.225.71872644
1×2402.61.227.62398775
1×3002.81.231.62982898
1×4003.11.434.538471060
1×5003.41.439.748531250

5.3 NSHXAFÖ 3.6/6 kV — High Medium Voltage Series

NSHXAFÖ 3.6/6 kV Technical Parameters
Cross-Section
(mm²)
Insulation Thickness
(mm)
Sheath Thickness
(mm)
Overall Diameter
(mm)
Net Weight
(kg/km)
DC Resistance
@ 20°C (Ω/km)
1×1.52.60.88.3 / 10.58813.7
1×2.52.60.88.8 / 11.51038.21
1×42.60.89.7 / 12.01305.09
1×62.60.810.2 / 13.01553.39
1×102.60.811.6 / 14.52151.95
1×162.61.012.7 / 15.52831.24
1×252.91.014.5 / 17.53930.795
1×352.91.015.2 / 19.04890.565
1×502.91.017.2 / 21.06510.393
1×702.91.019.0 / 23.08560.277
1×953.21.021.7 / 26.511090.210
1×1203.21.023.2 / 28.513690.164
1×1503.21.225.0 / 30.516520.132
1×1853.21.227.3 / 33.019650.108
1×2403.21.229.6 / 34.025260.0817

6. Insulation Thickness Comparison Across Voltage Classes

Understanding the relationship between voltage rating and insulation thickness is fundamental to cable selection. Higher voltage classes require proportionally thicker insulation to maintain adequate dielectric strength and ensure safe operation. The following comparison demonstrates how insulation requirements scale with voltage rating:

Cross-Section
(mm²)
0.6/1 kV
Insulation (mm)
1.8/3 kV
Insulation (mm)
3.6/6 kV
Insulation (mm)
Increase Factor
(1.8/3 vs 0.6/1)
Increase Factor
(3.6/6 vs 0.6/1)
1×1.50.81.32.61.63×3.25×
1×101.21.52.61.25×2.17×
1×501.61.82.91.13×1.81×
1×1201.82.23.21.22×1.78×
1×2402.42.63.21.08×1.33×

7. Applications and Use Cases

7.1 Primary Application: Wind Turbine Systems

The NSHXAFÖ cable series is engineered specifically for heavy-duty flexible single core power applications in both mobile and fixed installations within wind energy systems. The combination of halogen-free construction, excellent flexibility, and multi-voltage capability makes these cables ideal for the demanding environment inside wind turbine nacelles and towers.

Wind Energy Suitability: The halogen-free construction protects human life and valuable assets in the event of fire through low smoke density and minimal corrosive gas emission — critical safety characteristics for enclosed nacelle environments where maintenance personnel may be present.

7.2 Extended Industrial Applications

Beyond wind energy, the NSHXAFÖ cable finds extensive application across multiple industrial sectors. The VDE certification and comprehensive environmental resistance make it suitable for wiring of machines, tools, devices, appliances, and control cabinets where reliability and safety are paramount.

  • Wind turbine nacelle and tower power distribution
  • Railway vehicles and buses — short-circuit-proof up to 1000V
  • Switching stations and power distributors
  • Installation in ducts, tubes, pipes, conduits, and closed channels
  • Bundled cable installations
  • Connection of movable parts requiring flexibility
  • Machine wiring and control cabinet connections
  • Industrial equipment in harsh environmental conditions

7.3 Installation Considerations

The cable is suitable for both mobile (flexible) applications with minimum bending radius of 10× outer diameter and fixed installations with minimum bending radius of 6× outer diameter. Note that direct burial is not permitted except for lead-through applications such as fire separation sand cups.

8. Bending Radius Specifications

Installation TypeMinimum Bending RadiusApplication
Flexible/Mobile Use10 × Overall DiameterMoving parts, flexible connections
Fixed Installation6 × Overall DiameterPermanent routing, conduit runs

9. Standards and Compliance Reference

StandardScopeApplication
DIN VDE 0250 p.606Cable construction and performancePrimary product standard
DIN VDE 0207 p.20Insulation compound type 3GI3EPR insulation specification
DIN VDE 0207 p.24Sheath compound type HM3Halogen-free jacket specification
IEC 60228 / HD 383Conductor constructionClass 5 flexible stranded copper
IEC 60332-1-2Flame propagation testSingle cable vertical flame test
VDE 0100 Part 520Selection and installationShort circuit-proof installation
VDE 0298 Part 3Current carrying capacityInstallation derating factors

10. Packaging and Delivery

Standard delivery configuration is 1000 meters on wooden drums. Alternative packaging formats including smaller reels, cut-to-length options, and custom drum sizes are available upon request from Anhui Feichun Special Cable Co., Ltd. Custom jacket colors other than standard black can be provided for circuit identification purposes.

Request Technical Specifications or Quotation

Anhui Feichun Special Cable Co., Ltd. (安徽飞纯特种电缆有限公司) provides custom NSHXAFÖ cable solutions across all voltage classes for your wind energy and industrial project requirements. Our technical team offers application engineering support, cable sizing calculations, and comprehensive documentation packages including DIN VDE compliance certification.

Previous Article

What is DLO TORSIONFLEX RHH/RHW-2 2000V Wind Turbine Cable?

Next Article

What is Z-XOTKtsdDb Glass Yarn Reinforced Fiber Optic Cable?