What is PROTOMONT NSSHOEU 1 kV Low Voltage Flexible Rubber Cable?

A Comprehensive Technical Guide to Heavy-Duty Mining and Industrial Flexible Cables with EPR Insulation for Extreme Environments

What is PROTOMONT NSSHOEU 1 kV Low Voltage Flexible Rubber Cable?
A Comprehensive Technical Guide to Heavy-Duty Mining and Industrial Flexible Cables with EPR Insulation for Extreme Environments
What is PROTOMONT NSSHOEU 1 kV Low Voltage Flexible Rubber Cable? A Comprehensive Technical Guide to Heavy-Duty Mining and Industrial Flexible Cables with EPR Insulation for Extreme Environments
What is PROTOMONT NSSHOEU 1 kV Low Voltage Flexible Rubber Cable? | Anhui Feichun Special Cable Co., Ltd.

Anhui Feichun Special Cable Co., Ltd. (安徽飞纯特种电缆有限公司)

What is PROTOMONT NSSHOEU 1 kV Low Voltage Flexible Rubber Cable?

A Comprehensive Technical Guide to Heavy-Duty Mining and Industrial Flexible Cables with EPR Insulation for Extreme Environments

1. Introduction to PROTOMONT NSSHOEU Cables

The PROTOMONT NSSHOEU series represents a category of heavy-duty, low voltage flexible rubber cables engineered specifically for demanding industrial environments. These cables are designed to provide reliable power transmission in applications where conventional cables would fail due to extreme mechanical stress, environmental exposure, or chemical contact.

The designation NSSHOEU follows German cable nomenclature standards where each letter indicates specific construction characteristics. The cables are manufactured according to DIN VDE 0250-812 specifications, which define requirements for rubber-insulated flexible cables used in power installations. According to industry standards, these cables are engineered for environments where high levels of mechanical stress and abrasion are expected, making them essential for modern mining, construction, and industrial operations.

Key Specification Summary: PROTOMONT NSSHOEU cables operate at a rated voltage of 0.6/1 kV (600/1000V), with maximum permissible operating voltages of 0.7/1.2 kV AC and 0.9/1.8 kV DC. The cables feature EPR (Ethylene Propylene Rubber) insulation with a conductor temperature rating of 90°C and short-circuit temperature capability of 250°C.

As documented by Feichun Cables, these specialized cables meet the highest industry standards including AS/NZS 1802:2003, AS/NZS 2802:2000, VDE, ICEA, and CAN/CSA requirements, demonstrating their suitability for global mining and industrial applications.

2. Purpose and Applications

PROTOMONT NSSHOEU cables serve a critical role in powering equipment across various demanding industrial sectors. Their robust construction enables reliable operation in environments where standard cables would experience rapid degradation or failure.

2.1 Primary Application Areas

The cables are engineered for both flexible use and fixed installation in open-cast mining applications, quarries, construction sites, and similar environments with heavy mechanical stresses. Specific applications include indoor and outdoor installations, explosion-hazard areas, industrial facilities, and agricultural operations.

Mining and Quarrying Operations

In mining environments, these cables provide power to mobile and stationary equipment including continuous miners, drills, loaders, conveyors, and pumping systems. As noted by Amplex Mining, cables designed for Australian mining environments must meet stringent AS/NZS compliance requirements while delivering exceptional durability in harsh underground and surface conditions.

Submersible and Water Applications

A distinctive feature of PROTOMONT NSSHOEU cables is their exceptional water resistance capability. According to the manufacturer’s specifications, these cables can be used permanently in waste water up to 40°C at depths up to 2000 meters. They are also suitable for use in industrial water, cooling water, surface water, rainwater, mixed water, groundwater, and seawater to varying degrees depending on water composition.

Water Resistance Note: The requirements for accessibility and inspection depend on water consistency. In aggressive water or water composed of special substances, the cable’s resistance properties should be tested prior to installation. Specifications per DIN VDE 0298 Part 3 apply.

Construction and Heavy Industry

Construction sites present unique challenges including physical abuse, exposure to oils and chemicals, and variable weather conditions. As documented by Reeling Cable, cables for mobile machinery must demonstrate high tensile strength, resistance to saltwater and UV radiation, and advanced insulation and sheathing to prevent wear and electrical degradation. The PROTOMONT NSSHOEU design addresses these requirements through its multi-layer construction and specialized compound formulations.

Crane and Material Handling Equipment

Crane and hoisting applications demand cables that can withstand continuous reeling, torsion, and mechanical stress. Technical sources indicate that crane cables must be simultaneously robust and flexible to ensure reliability under high mechanical loads including traction, compression, abrasion, bending, and torsion. The PROTOMONT NSSHOEU series meets these requirements with its Class 5 finely stranded conductor construction.

3. Key Characteristics and Performance Features

The PROTOMONT NSSHOEU cable incorporates multiple design features that enable superior performance in demanding environments. Each characteristic has been optimized through extensive engineering to address specific operational challenges.

3.1 Mechanical Properties

PropertySpecificationSignificance
Maximum Tensile Load15 N/mm² (on conductor)Enables safe dragging and installation on slopes
Torsional Stress±100°/mAccommodates cable twisting during reeling operations
Bending RadiiPer DIN VDE 0298 Part 3Defines minimum bend without damage
Abrasion ResistanceHeavy-duty (5GM5 compound)Withstands dragging over rough surfaces

3.2 Environmental Resistance

The cable demonstrates comprehensive resistance to environmental factors that would degrade standard cables. Industry documentation confirms that EPR insulated cables are preferred for applications requiring excellent moisture resistance, flexibility, and ability to withstand harsh conditions, with applications ranging from marine platforms to underground mining operations.

Environmental FactorResistance LevelStandard Reference
Fire PerformanceFlame RetardantDIN EN 60332-1-2
Oil ResistanceHighDIN EN 60811-404
Weather ResistanceUnrestricted outdoor/indoor useOzone and moisture resistant
Water ResistanceSubmersible to 2000mDIN EN 50525-2-21
UV ResistanceYesSuitable for outdoor installation

3.3 Electrical Performance

The electrical characteristics of PROTOMONT NSSHOEU cables ensure reliable power transmission while maintaining safety margins for overcurrent and fault conditions.

ParameterValue
Rated Voltage (U₀/U)0.6/1 kV (600/1000V)
Maximum Operating Voltage AC0.7/1.2 kV
Maximum Operating Voltage DC0.9/1.8 kV
AC Test Voltage (Main Cores)3.5 kV (5 minutes)

4. Material Structure and Construction

The PROTOMONT NSSHOEU cable employs a multi-layer construction designed to optimize electrical performance, mechanical durability, and environmental resistance. Each component serves specific functions that contribute to overall cable reliability.

4.1 Conductor Construction

The conductor consists of electrolytic copper with tin plating, constructed in a finely stranded configuration conforming to Class 5 per DIN EN 60228 / IEC 60228. The tinning process provides corrosion protection while the fine stranding delivers superior flexibility for dynamic applications.

Conductor Class 5 Advantages: Class 5 stranding uses numerous fine copper wires twisted together, providing flexibility exceeding that of solid or Class 2 conductors. This construction allows repeated bending without conductor fatigue, essential for reeling and mobile applications. As noted by Mining Cable Chile, flexible bare copper conductors made from soft, high-quality copper provide excellent conductivity and flexibility for mining equipment.

4.2 Insulation System

The insulation utilizes PROTOLON, an EPR-based compound designated as Type 3GI3 per DIN EN 50363. Ethylene Propylene Rubber (EPR) provides excellent electrical insulation properties combined with thermal stability and moisture resistance.

Insulation PropertySpecification
Base MaterialEPR (Ethylene Propylene Rubber)
Compound Type3GI3 per DIN EN 50363
Temperature Rating90°C continuous, 250°C short-circuit
Dielectric PropertiesSuitable for voltages up to 138 kV

Technical documentation indicates that EPR insulation exhibits good resistance to water treeing, a phenomenon where water creates penetrating patterns through insulation that can eventually reach the conductor. EPR cables with ethylene-propylene copolymer construction offer low sensitivity to water treeing, making them ideal for offshore and outdoor applications in constant contact with water.

4.3 Core Identification

Core identification follows DIN VDE 0293-308 standards. Cables with up to 5 cores feature color-coded identification, while cables with 6 or more cores use light-colored insulation with black numbers for identification.

4.4 Inner Sheath

For multi-core cables, an inner sheath constructed from vulcanized rubber compound (EPR base material, GM1B type per DIN EN 50363) provides additional mechanical protection and maintains core positioning. Single-core cables do not incorporate an inner sheath.

4.5 Outer Sheath

The outer sheath consists of vulcanized rubber compound using synthetic elastomer (CPE – Chlorinated Polyethylene or equivalent), designated as Compound Type 5GM5 per DIN EN 50363. The standard color is yellow, providing high visibility in industrial environments.

Outer Sheath PropertySpecification
Base MaterialSynthetic Elastomer (e.g., CPE)
Compound Type5GM5 per DIN EN 50363
Standard ColorYellow
Oil ResistancePer DIN EN 60811-404
Flame RetardancyPer DIN EN 60332-1-2

5. Technical Specifications and Parameters

The following tables present detailed technical parameters for various PROTOMONT NSSHOEU cable configurations. Data is organized by core count and cross-sectional area to facilitate selection for specific applications.

5.1 Thermal Parameters

ParameterValueCondition
Maximum Conductor Operating Temperature90°CContinuous operation
Maximum Short-Circuit Temperature250°CFault condition
Maximum Water Temperature40°CSubmersed operation*
Ambient Temperature (Fixed)-40°C to +80°CFixed installation
Ambient Temperature (Flexible)-25°C to +60°CFully flexible operation

*Note: At higher water temperatures, shortened cable service life is to be expected.

5.2 Single-Core Cable Specifications (PROTOMONT NSSHÖU-0 1x)

Cross Section (mm²)Conductor Ø (mm)Outer Ø min (mm)Outer Ø max (mm)Weight (kg/km)Resistance @20°C (Ω/km)Current Capacity (A)
165.410.611.62401.21135
256.31013.73600.7839178
357.413.714.96300.554220
508.815.216.78500.396275
7010.614.518.810700.272340
9512.119.420.913700.206409
12014.318.323.416600.161479
15015.923.925.420600.129549
18517.526.628.826300.106627
24020.329.83233000.0801734
30023.134.636.842600.0641843
40026.239.540.560000.04861024

5.3 Three-Core Cable Specifications (PROTOMONT NSSHÖU-1 3x)

Cross Section (mm²)Conductor Ø (mm)Outer Ø min (mm)Outer Ø max (mm)Weight (kg/km)Resistance @20°C (Ω/km)Current Capacity (A)
1.51.610.712.322013.323
2.51.91213.63207.9830
42.414.216.24204.9541
62.916.618.65203.3153
103.911.513.19301.9174
165.413.715.711901.2199
256.315.317.314800.7839131
357.516.518.517400.554162
508.920.922.920000.396202
7010.625.927.924500.272250

Current carrying capacity based on rubber cables laid on surface at 30°C ambient temperature per VDE 0298-4, Table 15.

5.4 Electrical Parameters by Cross Section

Cross Section (mm²)Resistance @20°C max (Ω/km)Capacitance (μF/km)Inductance (mH/km)Short-Circuit Current (kA)
1.513.30.220.330.21
2.57.980.230.320.36
44.950.260.310.57
63.310.300.290.86
101.910.320.281.43
161.210.420.262.29
250.78390.420.263.58
350.5540.490.255.01
500.3960.510.257.15
700.2720.590.2410.01
950.2060.600.2413.59
1200.1610.690.2317.16
1500.1290.700.2321.45
1850.1060.710.2326.46
2400.08010.730.2334.32

6. Compliance Standards and Certifications

PROTOMONT NSSHOEU cables are manufactured in accordance with stringent international standards and hold multiple certifications validating their suitability for demanding applications worldwide.

6.1 Primary Manufacturing Standard

The cables are produced according to DIN VDE 0250-812, the German national standard that specifies requirements for rubber-insulated flexible cables NSSHÖU. According to Eland Cables, Germany is the only country to have issued special design regulations for flexible electrical cables covering cranes and material handling equipment, and DIN VDE 0250 has found global recognition as the standard for tough rubber sheathed flexible reeling cables.

6.2 Certifications and Approvals

MA – China MSHA P-189-3 EAC Certificate DIN VDE 0250-812
CertificationDescriptionApplication Region
MA – ChinaCoal Mine Safety CertificationChina
MSHA P-189-3Mine Safety and Health Administration approvalUnited States
EAC CertificateEurasian Conformity certificationRussia, Belarus, Kazakhstan, Armenia, Kyrgyzstan

6.3 Referenced Standards

StandardDescription
DIN EN 60228 / IEC 60228Conductor specifications (Class 5)
DIN EN 50363Insulation and sheath compound specifications
DIN VDE 0293-308Core identification colors
DIN VDE 0298 Part 3Usage specifications and installation guidance
DIN EN 60332-1-2Fire performance testing
DIN EN 60811-404Oil resistance testing
DIN EN 50525-2-21Water resistance specifications

7. Safety Thresholds and Operating Limits

Understanding and adhering to safety thresholds is critical for reliable cable operation and personnel safety. The following parameters define the operational boundaries for PROTOMONT NSSHOEU cables.

7.1 Voltage Limits

ParameterAC ValueDC Value
Rated Voltage (U₀/U)0.6/1 kV–
Maximum Operating Voltage0.7/1.2 kV0.9/1.8 kV
Test Voltage (5 min)3.5 kV–

7.2 Temperature Limits

⚠️ Critical Temperature Thresholds

Operating beyond these temperature limits can result in accelerated cable degradation, reduced service life, or immediate failure. The maximum conductor temperature of 90°C must not be exceeded during normal operation. Short-circuit temperature of 250°C is permissible only during fault conditions of limited duration.

Temperature ParameterLimitNotes
Maximum Conductor Temperature90°CContinuous operation limit
Short-Circuit Temperature250°CFault condition only
Water Temperature (submersed)40°CHigher temperatures reduce service life
Minimum (Fixed Installation)-40°CStatic applications
Maximum (Fixed Installation)+80°CStatic applications
Minimum (Flexible Operation)-25°CDynamic/moving applications
Maximum (Flexible Operation)+60°CDynamic/moving applications

7.3 Mechanical Limits

ParameterLimitApplication
Maximum Tensile Load on Conductor15 N/mm²During installation/operation
Torsional Stress±100°/mReeling applications
Maximum Submersion Depth2000 metersWater temperature ≤40°C
Minimum Bending RadiusPer DIN VDE 0298 Part 3Varies by cable size

7.4 Current Derating Factors

The nominal current carrying capacities specified assume cables laid on a surface at 30°C ambient temperature. When operating under different conditions, derating factors must be applied:

ConditionDerating Factor
Ambient 40°C0.91
Ambient 50°C0.82
Cables wound on reelSee VDE 0298-4 tables
Multiple cables groupedSee VDE 0298-4 tables

8. Installation and Usage Precautions

Proper installation and handling procedures are essential to maximize cable service life and maintain safe operation. The following guidelines address key considerations for various installation scenarios.

8.1 Installation Guidelines

Handling and Storage

  • Store cables in a dry, clean environment away from direct sunlight when not in use
  • Maintain storage temperature between -25°C and +50°C
  • Avoid contact with sharp edges or abrasive surfaces during transport
  • Do not drag cables over rough surfaces without protective measures

Installation Requirements

  • Observe minimum bending radii specified in DIN VDE 0298 Part 3
  • Provide strain relief at connection points to prevent conductor fatigue
  • Ensure adequate support to prevent excessive cable sag
  • Protect cables from mechanical damage in high-traffic areas

Important: According to technical documentation, at the connection of mobile equipment, NSSHÖU cables must be discharged from tensile and thrust forces at insertion points and safeguarded against torsion and bending at terminations.

8.2 Submersible Installation Considerations

When installing cables for submersible applications, additional precautions apply:

  • Verify water composition before installation; test cable resistance properties in aggressive water or water with special substances
  • Ensure maximum water temperature does not exceed 40°C for rated service life
  • Establish inspection schedule appropriate to water conditions
  • Consider seawater and groundwater as having more limited suitability compared to freshwater applications

8.3 Explosion-Hazard Area Installation

⚠️ Explosion-Hazard Areas

Installation in explosion-hazard areas must comply with local regulations and standards. Consult applicable codes (e.g., ATEX, IECEx) and engage qualified personnel for design and installation. Ensure all cable entries and terminations meet explosion-protection requirements.

8.4 Prohibited Applications

Per DIN VDE 0298 Part 3, PROTOMONT NSSHOEU cables are not suitable for:

  • Direct burial in soil (without additional protection)
  • Fixed installation behind fire-retarding seals or sand cups (except temporary covering at construction sites)
  • Applications exceeding maximum voltage or temperature ratings
  • Use without proper strain relief at mobile equipment connections

8.5 Inspection and Maintenance

Regular inspection ensures continued safe operation:

  • Visually inspect cables regularly for cuts, abrasions, or deformation
  • Check terminations for signs of overheating or loosening
  • Test insulation resistance periodically per applicable standards
  • Replace cables showing significant wear or damage
  • Maintain documentation of inspections and test results

9. Technical Data Comparison Tables

9.1 Four-Core Cable Specifications (PROTOMONT NSSHÖU-1 4x)

Cross Section (mm²)Outer Ø min (mm)Outer Ø max (mm)Weight (kg/km)Resistance @20°C (Ω/km)Current Capacity (A)
1.511.513.127013.323
2.513.715.74007.9831
415.317.34154.9542
616.518.56803.3153
1020.922.98901.9174
1625.927.913301.2199
2529.332.417700.7839131
3532.135.122000.554162
5038.241.230500.396202
7042.545.539800.272249

9.2 Five-Core Cable Specifications (PROTOMONT NSSHÖU-1 5x)

Cross Section (mm²)Outer Ø min (mm)Outer Ø max (mm)Weight (kg/km)Max Tensile Force (N)Current Capacity (A)
1.512.414.925011323
2.514.716.937018829
416.518.549030041
617.720.365045053
1024.527.398075074
1629.734.81420120099
2534.840.120801875131
3540.144.527602625162
5044.553.436703750202
705157.450505250246

9.3 Multi-Core Cable Specifications (7 to 24 cores)

ConfigurationOuter Ø min (mm)Outer Ø max (mm)Weight (kg/km)Resistance @20°C (Ω/km)
7×1.514.916.938013.3
8×1.516.118.143013.3
10×1.517.719.747013.3
12×1.519.720.356013.3
19×1.522.323.765013.3
24×1.524.327.354013.3
7×2.516.918.95007.98
10×2.522.623.66507.98
12×2.520.722.77507.98
7×420227104.95
12×423.526.510604.95

9.4 Cables with Ground Conductor (3×…+3×…/3)

ConfigurationOuter Ø min (mm)Outer Ø max (mm)Weight (kg/km)Max Tensile Force (N)
3×50/2538.241.228903000
3×70/3542.545.537504200
3×95/5048.352.349405700
3×120/7054.858.863807200
3×150/7060.264.276609000
3×185/9567.371.3949011100
3×240/12072.476.41162014400

10. Frequently Asked Questions

What does the designation NSSHOEU mean?

The designation follows German cable nomenclature per DIN VDE standards: N = standard type, SS = special rubber with reinforced protection, H = halogen-free or heavy-duty compound, O = without concentric conductor, E = copper screening element, U = rubber outer sheath. The “J” suffix (NSSHOEU-J) indicates inclusion of a green/yellow protective earth conductor, while “O” suffix (NSSHOEU-O) indicates absence of protective earth conductor.

What is the maximum submersible depth for PROTOMONT NSSHOEU cables?

PROTOMONT NSSHOEU cables can be permanently submerged in water up to 2000 meters depth at temperatures up to 40°C. This exceptional depth rating makes them suitable for deep-water mining, pump applications, and industrial water processing systems. At higher water temperatures, reduced service life should be expected.

Can NSSHOEU cables be used in explosive atmospheres?

Yes, PROTOMONT NSSHOEU cables are suitable for use in explosion-hazard areas, subject to local regulations. The cables hold MA-China certification for coal mine safety and MSHA P-189-3 approval for US mining applications. Installation must comply with applicable explosion protection standards (ATEX, IECEx) and be performed by qualified personnel.

What is the difference between NSSHOEU-O and NSSHOEU-J?

NSSHOEU-J cables include a green/yellow protective earth (PE) conductor, making them suitable for applications requiring equipment earthing through the cable. NSSHOEU-O cables do not include this protective earth conductor and are used where earthing is provided through other means or where an earth conductor is not required.

What is the temperature range for flexible operation?

For fully flexible operation (continuous bending and movement), the ambient temperature range is -25°C to +60°C. For fixed installations without movement, the cable can operate in ambient temperatures from -40°C to +80°C. The maximum conductor operating temperature is 90°C for both applications.

Are NSSHOEU cables resistant to oils and chemicals?

Yes, the outer sheath compound (5GM5 per DIN EN 50363) provides excellent resistance to oils and fats per DIN EN 60811-404. The cable also resists many chemicals encountered in mining and industrial environments. However, for aggressive chemicals or unusual substances, resistance properties should be tested prior to installation.

What sizes are available for PROTOMONT NSSHOEU cables?

PROTOMONT NSSHOEU cables are available in a comprehensive range of configurations. Single-core cables range from 16mm² to 400mm². Multi-core options include 2-core through 24-core configurations in cross-sections from 1.5mm² to 240mm². Special configurations with ground conductors (3×…+3×…/3) are available for applications requiring integrated earthing. Special designs can be manufactured upon request.

What certifications does the cable hold for international use?

PROTOMONT NSSHOEU cables hold multiple international certifications including DIN VDE 0250-812 (Germany/EU), MA-China for Chinese coal mine safety applications, MSHA P-189-3 for US mining operations, and EAC Certificate for the Eurasian Economic Union (Russia, Belarus, Kazakhstan, Armenia, Kyrgyzstan). Additional certifications may be available upon request for specific markets.

Contact Anhui Feichun Special Cable Co., Ltd.

For technical inquiries, quotations, or custom cable requirements, please contact our specialist team:

💬 WhatsApp: +86 138 5512 3218

Visit our websites: feichuncable.com | feichuncables.com

References and Further Reading

Previous Article

What is PROTOLON(M) F (N)TSCGEWOEU 3 kV – 30 kV Medium Voltage Reeling Cable?

Next Article

What is PROTOMONT NSSHOEU 1 kV Low Voltage Flexible Rubber Cable?

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注