A Comprehensive Technical Guide to Heavy-Duty Mining and Industrial Flexible Cables with EPR Insulation for Extreme Environments

Anhui Feichun Special Cable Co., Ltd. (安徽飞纯特种电缆有限公司)
What is PROTOMONT NSSHOEU 1 kV Low Voltage Flexible Rubber Cable?
A Comprehensive Technical Guide to Heavy-Duty Mining and Industrial Flexible Cables with EPR Insulation for Extreme Environments
1. Introduction to PROTOMONT NSSHOEU Cables
The PROTOMONT NSSHOEU series represents a category of heavy-duty, low voltage flexible rubber cables engineered specifically for demanding industrial environments. These cables are designed to provide reliable power transmission in applications where conventional cables would fail due to extreme mechanical stress, environmental exposure, or chemical contact.
The designation NSSHOEU follows German cable nomenclature standards where each letter indicates specific construction characteristics. The cables are manufactured according to DIN VDE 0250-812 specifications, which define requirements for rubber-insulated flexible cables used in power installations. According to industry standards, these cables are engineered for environments where high levels of mechanical stress and abrasion are expected, making them essential for modern mining, construction, and industrial operations.
Key Specification Summary: PROTOMONT NSSHOEU cables operate at a rated voltage of 0.6/1 kV (600/1000V), with maximum permissible operating voltages of 0.7/1.2 kV AC and 0.9/1.8 kV DC. The cables feature EPR (Ethylene Propylene Rubber) insulation with a conductor temperature rating of 90°C and short-circuit temperature capability of 250°C.
As documented by Feichun Cables, these specialized cables meet the highest industry standards including AS/NZS 1802:2003, AS/NZS 2802:2000, VDE, ICEA, and CAN/CSA requirements, demonstrating their suitability for global mining and industrial applications.
2. Purpose and Applications
PROTOMONT NSSHOEU cables serve a critical role in powering equipment across various demanding industrial sectors. Their robust construction enables reliable operation in environments where standard cables would experience rapid degradation or failure.
2.1 Primary Application Areas
The cables are engineered for both flexible use and fixed installation in open-cast mining applications, quarries, construction sites, and similar environments with heavy mechanical stresses. Specific applications include indoor and outdoor installations, explosion-hazard areas, industrial facilities, and agricultural operations.
Mining and Quarrying Operations
In mining environments, these cables provide power to mobile and stationary equipment including continuous miners, drills, loaders, conveyors, and pumping systems. As noted by Amplex Mining, cables designed for Australian mining environments must meet stringent AS/NZS compliance requirements while delivering exceptional durability in harsh underground and surface conditions.
Submersible and Water Applications
A distinctive feature of PROTOMONT NSSHOEU cables is their exceptional water resistance capability. According to the manufacturer’s specifications, these cables can be used permanently in waste water up to 40°C at depths up to 2000 meters. They are also suitable for use in industrial water, cooling water, surface water, rainwater, mixed water, groundwater, and seawater to varying degrees depending on water composition.
Water Resistance Note: The requirements for accessibility and inspection depend on water consistency. In aggressive water or water composed of special substances, the cable’s resistance properties should be tested prior to installation. Specifications per DIN VDE 0298 Part 3 apply.
Construction and Heavy Industry
Construction sites present unique challenges including physical abuse, exposure to oils and chemicals, and variable weather conditions. As documented by Reeling Cable, cables for mobile machinery must demonstrate high tensile strength, resistance to saltwater and UV radiation, and advanced insulation and sheathing to prevent wear and electrical degradation. The PROTOMONT NSSHOEU design addresses these requirements through its multi-layer construction and specialized compound formulations.
Crane and Material Handling Equipment
Crane and hoisting applications demand cables that can withstand continuous reeling, torsion, and mechanical stress. Technical sources indicate that crane cables must be simultaneously robust and flexible to ensure reliability under high mechanical loads including traction, compression, abrasion, bending, and torsion. The PROTOMONT NSSHOEU series meets these requirements with its Class 5 finely stranded conductor construction.
3. Key Characteristics and Performance Features
The PROTOMONT NSSHOEU cable incorporates multiple design features that enable superior performance in demanding environments. Each characteristic has been optimized through extensive engineering to address specific operational challenges.
3.1 Mechanical Properties
| Property | Specification | Significance |
|---|---|---|
| Maximum Tensile Load | 15 N/mm² (on conductor) | Enables safe dragging and installation on slopes |
| Torsional Stress | ±100°/m | Accommodates cable twisting during reeling operations |
| Bending Radii | Per DIN VDE 0298 Part 3 | Defines minimum bend without damage |
| Abrasion Resistance | Heavy-duty (5GM5 compound) | Withstands dragging over rough surfaces |
3.2 Environmental Resistance
The cable demonstrates comprehensive resistance to environmental factors that would degrade standard cables. Industry documentation confirms that EPR insulated cables are preferred for applications requiring excellent moisture resistance, flexibility, and ability to withstand harsh conditions, with applications ranging from marine platforms to underground mining operations.
| Environmental Factor | Resistance Level | Standard Reference |
|---|---|---|
| Fire Performance | Flame Retardant | DIN EN 60332-1-2 |
| Oil Resistance | High | DIN EN 60811-404 |
| Weather Resistance | Unrestricted outdoor/indoor use | Ozone and moisture resistant |
| Water Resistance | Submersible to 2000m | DIN EN 50525-2-21 |
| UV Resistance | Yes | Suitable for outdoor installation |
3.3 Electrical Performance
The electrical characteristics of PROTOMONT NSSHOEU cables ensure reliable power transmission while maintaining safety margins for overcurrent and fault conditions.
| Parameter | Value |
|---|---|
| Rated Voltage (U₀/U) | 0.6/1 kV (600/1000V) |
| Maximum Operating Voltage AC | 0.7/1.2 kV |
| Maximum Operating Voltage DC | 0.9/1.8 kV |
| AC Test Voltage (Main Cores) | 3.5 kV (5 minutes) |
4. Material Structure and Construction
The PROTOMONT NSSHOEU cable employs a multi-layer construction designed to optimize electrical performance, mechanical durability, and environmental resistance. Each component serves specific functions that contribute to overall cable reliability.
4.1 Conductor Construction
The conductor consists of electrolytic copper with tin plating, constructed in a finely stranded configuration conforming to Class 5 per DIN EN 60228 / IEC 60228. The tinning process provides corrosion protection while the fine stranding delivers superior flexibility for dynamic applications.
Conductor Class 5 Advantages: Class 5 stranding uses numerous fine copper wires twisted together, providing flexibility exceeding that of solid or Class 2 conductors. This construction allows repeated bending without conductor fatigue, essential for reeling and mobile applications. As noted by Mining Cable Chile, flexible bare copper conductors made from soft, high-quality copper provide excellent conductivity and flexibility for mining equipment.
4.2 Insulation System
The insulation utilizes PROTOLON, an EPR-based compound designated as Type 3GI3 per DIN EN 50363. Ethylene Propylene Rubber (EPR) provides excellent electrical insulation properties combined with thermal stability and moisture resistance.
| Insulation Property | Specification |
|---|---|
| Base Material | EPR (Ethylene Propylene Rubber) |
| Compound Type | 3GI3 per DIN EN 50363 |
| Temperature Rating | 90°C continuous, 250°C short-circuit |
| Dielectric Properties | Suitable for voltages up to 138 kV |
Technical documentation indicates that EPR insulation exhibits good resistance to water treeing, a phenomenon where water creates penetrating patterns through insulation that can eventually reach the conductor. EPR cables with ethylene-propylene copolymer construction offer low sensitivity to water treeing, making them ideal for offshore and outdoor applications in constant contact with water.
4.3 Core Identification
Core identification follows DIN VDE 0293-308 standards. Cables with up to 5 cores feature color-coded identification, while cables with 6 or more cores use light-colored insulation with black numbers for identification.
4.4 Inner Sheath
For multi-core cables, an inner sheath constructed from vulcanized rubber compound (EPR base material, GM1B type per DIN EN 50363) provides additional mechanical protection and maintains core positioning. Single-core cables do not incorporate an inner sheath.
4.5 Outer Sheath
The outer sheath consists of vulcanized rubber compound using synthetic elastomer (CPE – Chlorinated Polyethylene or equivalent), designated as Compound Type 5GM5 per DIN EN 50363. The standard color is yellow, providing high visibility in industrial environments.
| Outer Sheath Property | Specification |
|---|---|
| Base Material | Synthetic Elastomer (e.g., CPE) |
| Compound Type | 5GM5 per DIN EN 50363 |
| Standard Color | Yellow |
| Oil Resistance | Per DIN EN 60811-404 |
| Flame Retardancy | Per DIN EN 60332-1-2 |
5. Technical Specifications and Parameters
The following tables present detailed technical parameters for various PROTOMONT NSSHOEU cable configurations. Data is organized by core count and cross-sectional area to facilitate selection for specific applications.
5.1 Thermal Parameters
| Parameter | Value | Condition |
|---|---|---|
| Maximum Conductor Operating Temperature | 90°C | Continuous operation |
| Maximum Short-Circuit Temperature | 250°C | Fault condition |
| Maximum Water Temperature | 40°C | Submersed operation* |
| Ambient Temperature (Fixed) | -40°C to +80°C | Fixed installation |
| Ambient Temperature (Flexible) | -25°C to +60°C | Fully flexible operation |
*Note: At higher water temperatures, shortened cable service life is to be expected.
5.2 Single-Core Cable Specifications (PROTOMONT NSSHÖU-0 1x)
| Cross Section (mm²) | Conductor Ø (mm) | Outer Ø min (mm) | Outer Ø max (mm) | Weight (kg/km) | Resistance @20°C (Ω/km) | Current Capacity (A) |
|---|---|---|---|---|---|---|
| 16 | 5.4 | 10.6 | 11.6 | 240 | 1.21 | 135 |
| 25 | 6.3 | 10 | 13.7 | 360 | 0.7839 | 178 |
| 35 | 7.4 | 13.7 | 14.9 | 630 | 0.554 | 220 |
| 50 | 8.8 | 15.2 | 16.7 | 850 | 0.396 | 275 |
| 70 | 10.6 | 14.5 | 18.8 | 1070 | 0.272 | 340 |
| 95 | 12.1 | 19.4 | 20.9 | 1370 | 0.206 | 409 |
| 120 | 14.3 | 18.3 | 23.4 | 1660 | 0.161 | 479 |
| 150 | 15.9 | 23.9 | 25.4 | 2060 | 0.129 | 549 |
| 185 | 17.5 | 26.6 | 28.8 | 2630 | 0.106 | 627 |
| 240 | 20.3 | 29.8 | 32 | 3300 | 0.0801 | 734 |
| 300 | 23.1 | 34.6 | 36.8 | 4260 | 0.0641 | 843 |
| 400 | 26.2 | 39.5 | 40.5 | 6000 | 0.0486 | 1024 |
5.3 Three-Core Cable Specifications (PROTOMONT NSSHÖU-1 3x)
| Cross Section (mm²) | Conductor Ø (mm) | Outer Ø min (mm) | Outer Ø max (mm) | Weight (kg/km) | Resistance @20°C (Ω/km) | Current Capacity (A) |
|---|---|---|---|---|---|---|
| 1.5 | 1.6 | 10.7 | 12.3 | 220 | 13.3 | 23 |
| 2.5 | 1.9 | 12 | 13.6 | 320 | 7.98 | 30 |
| 4 | 2.4 | 14.2 | 16.2 | 420 | 4.95 | 41 |
| 6 | 2.9 | 16.6 | 18.6 | 520 | 3.31 | 53 |
| 10 | 3.9 | 11.5 | 13.1 | 930 | 1.91 | 74 |
| 16 | 5.4 | 13.7 | 15.7 | 1190 | 1.21 | 99 |
| 25 | 6.3 | 15.3 | 17.3 | 1480 | 0.7839 | 131 |
| 35 | 7.5 | 16.5 | 18.5 | 1740 | 0.554 | 162 |
| 50 | 8.9 | 20.9 | 22.9 | 2000 | 0.396 | 202 |
| 70 | 10.6 | 25.9 | 27.9 | 2450 | 0.272 | 250 |
Current carrying capacity based on rubber cables laid on surface at 30°C ambient temperature per VDE 0298-4, Table 15.
5.4 Electrical Parameters by Cross Section
| Cross Section (mm²) | Resistance @20°C max (Ω/km) | Capacitance (μF/km) | Inductance (mH/km) | Short-Circuit Current (kA) |
|---|---|---|---|---|
| 1.5 | 13.3 | 0.22 | 0.33 | 0.21 |
| 2.5 | 7.98 | 0.23 | 0.32 | 0.36 |
| 4 | 4.95 | 0.26 | 0.31 | 0.57 |
| 6 | 3.31 | 0.30 | 0.29 | 0.86 |
| 10 | 1.91 | 0.32 | 0.28 | 1.43 |
| 16 | 1.21 | 0.42 | 0.26 | 2.29 |
| 25 | 0.7839 | 0.42 | 0.26 | 3.58 |
| 35 | 0.554 | 0.49 | 0.25 | 5.01 |
| 50 | 0.396 | 0.51 | 0.25 | 7.15 |
| 70 | 0.272 | 0.59 | 0.24 | 10.01 |
| 95 | 0.206 | 0.60 | 0.24 | 13.59 |
| 120 | 0.161 | 0.69 | 0.23 | 17.16 |
| 150 | 0.129 | 0.70 | 0.23 | 21.45 |
| 185 | 0.106 | 0.71 | 0.23 | 26.46 |
| 240 | 0.0801 | 0.73 | 0.23 | 34.32 |
6. Compliance Standards and Certifications
PROTOMONT NSSHOEU cables are manufactured in accordance with stringent international standards and hold multiple certifications validating their suitability for demanding applications worldwide.
6.1 Primary Manufacturing Standard
The cables are produced according to DIN VDE 0250-812, the German national standard that specifies requirements for rubber-insulated flexible cables NSSHÖU. According to Eland Cables, Germany is the only country to have issued special design regulations for flexible electrical cables covering cranes and material handling equipment, and DIN VDE 0250 has found global recognition as the standard for tough rubber sheathed flexible reeling cables.
6.2 Certifications and Approvals
| Certification | Description | Application Region |
|---|---|---|
| MA – China | Coal Mine Safety Certification | China |
| MSHA P-189-3 | Mine Safety and Health Administration approval | United States |
| EAC Certificate | Eurasian Conformity certification | Russia, Belarus, Kazakhstan, Armenia, Kyrgyzstan |
6.3 Referenced Standards
| Standard | Description |
|---|---|
| DIN EN 60228 / IEC 60228 | Conductor specifications (Class 5) |
| DIN EN 50363 | Insulation and sheath compound specifications |
| DIN VDE 0293-308 | Core identification colors |
| DIN VDE 0298 Part 3 | Usage specifications and installation guidance |
| DIN EN 60332-1-2 | Fire performance testing |
| DIN EN 60811-404 | Oil resistance testing |
| DIN EN 50525-2-21 | Water resistance specifications |
7. Safety Thresholds and Operating Limits
Understanding and adhering to safety thresholds is critical for reliable cable operation and personnel safety. The following parameters define the operational boundaries for PROTOMONT NSSHOEU cables.
7.1 Voltage Limits
| Parameter | AC Value | DC Value |
|---|---|---|
| Rated Voltage (U₀/U) | 0.6/1 kV | – |
| Maximum Operating Voltage | 0.7/1.2 kV | 0.9/1.8 kV |
| Test Voltage (5 min) | 3.5 kV | – |
7.2 Temperature Limits
⚠️ Critical Temperature Thresholds
Operating beyond these temperature limits can result in accelerated cable degradation, reduced service life, or immediate failure. The maximum conductor temperature of 90°C must not be exceeded during normal operation. Short-circuit temperature of 250°C is permissible only during fault conditions of limited duration.
| Temperature Parameter | Limit | Notes |
|---|---|---|
| Maximum Conductor Temperature | 90°C | Continuous operation limit |
| Short-Circuit Temperature | 250°C | Fault condition only |
| Water Temperature (submersed) | 40°C | Higher temperatures reduce service life |
| Minimum (Fixed Installation) | -40°C | Static applications |
| Maximum (Fixed Installation) | +80°C | Static applications |
| Minimum (Flexible Operation) | -25°C | Dynamic/moving applications |
| Maximum (Flexible Operation) | +60°C | Dynamic/moving applications |
7.3 Mechanical Limits
| Parameter | Limit | Application |
|---|---|---|
| Maximum Tensile Load on Conductor | 15 N/mm² | During installation/operation |
| Torsional Stress | ±100°/m | Reeling applications |
| Maximum Submersion Depth | 2000 meters | Water temperature ≤40°C |
| Minimum Bending Radius | Per DIN VDE 0298 Part 3 | Varies by cable size |
7.4 Current Derating Factors
The nominal current carrying capacities specified assume cables laid on a surface at 30°C ambient temperature. When operating under different conditions, derating factors must be applied:
| Condition | Derating Factor |
|---|---|
| Ambient 40°C | 0.91 |
| Ambient 50°C | 0.82 |
| Cables wound on reel | See VDE 0298-4 tables |
| Multiple cables grouped | See VDE 0298-4 tables |
8. Installation and Usage Precautions
Proper installation and handling procedures are essential to maximize cable service life and maintain safe operation. The following guidelines address key considerations for various installation scenarios.
8.1 Installation Guidelines
Handling and Storage
- Store cables in a dry, clean environment away from direct sunlight when not in use
- Maintain storage temperature between -25°C and +50°C
- Avoid contact with sharp edges or abrasive surfaces during transport
- Do not drag cables over rough surfaces without protective measures
Installation Requirements
- Observe minimum bending radii specified in DIN VDE 0298 Part 3
- Provide strain relief at connection points to prevent conductor fatigue
- Ensure adequate support to prevent excessive cable sag
- Protect cables from mechanical damage in high-traffic areas
Important: According to technical documentation, at the connection of mobile equipment, NSSHÖU cables must be discharged from tensile and thrust forces at insertion points and safeguarded against torsion and bending at terminations.
8.2 Submersible Installation Considerations
When installing cables for submersible applications, additional precautions apply:
- Verify water composition before installation; test cable resistance properties in aggressive water or water with special substances
- Ensure maximum water temperature does not exceed 40°C for rated service life
- Establish inspection schedule appropriate to water conditions
- Consider seawater and groundwater as having more limited suitability compared to freshwater applications
8.3 Explosion-Hazard Area Installation
⚠️ Explosion-Hazard Areas
Installation in explosion-hazard areas must comply with local regulations and standards. Consult applicable codes (e.g., ATEX, IECEx) and engage qualified personnel for design and installation. Ensure all cable entries and terminations meet explosion-protection requirements.
8.4 Prohibited Applications
Per DIN VDE 0298 Part 3, PROTOMONT NSSHOEU cables are not suitable for:
- Direct burial in soil (without additional protection)
- Fixed installation behind fire-retarding seals or sand cups (except temporary covering at construction sites)
- Applications exceeding maximum voltage or temperature ratings
- Use without proper strain relief at mobile equipment connections
8.5 Inspection and Maintenance
Regular inspection ensures continued safe operation:
- Visually inspect cables regularly for cuts, abrasions, or deformation
- Check terminations for signs of overheating or loosening
- Test insulation resistance periodically per applicable standards
- Replace cables showing significant wear or damage
- Maintain documentation of inspections and test results
9. Technical Data Comparison Tables
9.1 Four-Core Cable Specifications (PROTOMONT NSSHÖU-1 4x)
| Cross Section (mm²) | Outer Ø min (mm) | Outer Ø max (mm) | Weight (kg/km) | Resistance @20°C (Ω/km) | Current Capacity (A) |
|---|---|---|---|---|---|
| 1.5 | 11.5 | 13.1 | 270 | 13.3 | 23 |
| 2.5 | 13.7 | 15.7 | 400 | 7.98 | 31 |
| 4 | 15.3 | 17.3 | 415 | 4.95 | 42 |
| 6 | 16.5 | 18.5 | 680 | 3.31 | 53 |
| 10 | 20.9 | 22.9 | 890 | 1.91 | 74 |
| 16 | 25.9 | 27.9 | 1330 | 1.21 | 99 |
| 25 | 29.3 | 32.4 | 1770 | 0.7839 | 131 |
| 35 | 32.1 | 35.1 | 2200 | 0.554 | 162 |
| 50 | 38.2 | 41.2 | 3050 | 0.396 | 202 |
| 70 | 42.5 | 45.5 | 3980 | 0.272 | 249 |
9.2 Five-Core Cable Specifications (PROTOMONT NSSHÖU-1 5x)
| Cross Section (mm²) | Outer Ø min (mm) | Outer Ø max (mm) | Weight (kg/km) | Max Tensile Force (N) | Current Capacity (A) |
|---|---|---|---|---|---|
| 1.5 | 12.4 | 14.9 | 250 | 113 | 23 |
| 2.5 | 14.7 | 16.9 | 370 | 188 | 29 |
| 4 | 16.5 | 18.5 | 490 | 300 | 41 |
| 6 | 17.7 | 20.3 | 650 | 450 | 53 |
| 10 | 24.5 | 27.3 | 980 | 750 | 74 |
| 16 | 29.7 | 34.8 | 1420 | 1200 | 99 |
| 25 | 34.8 | 40.1 | 2080 | 1875 | 131 |
| 35 | 40.1 | 44.5 | 2760 | 2625 | 162 |
| 50 | 44.5 | 53.4 | 3670 | 3750 | 202 |
| 70 | 51 | 57.4 | 5050 | 5250 | 246 |
9.3 Multi-Core Cable Specifications (7 to 24 cores)
| Configuration | Outer Ø min (mm) | Outer Ø max (mm) | Weight (kg/km) | Resistance @20°C (Ω/km) |
|---|---|---|---|---|
| 7×1.5 | 14.9 | 16.9 | 380 | 13.3 |
| 8×1.5 | 16.1 | 18.1 | 430 | 13.3 |
| 10×1.5 | 17.7 | 19.7 | 470 | 13.3 |
| 12×1.5 | 19.7 | 20.3 | 560 | 13.3 |
| 19×1.5 | 22.3 | 23.7 | 650 | 13.3 |
| 24×1.5 | 24.3 | 27.3 | 540 | 13.3 |
| 7×2.5 | 16.9 | 18.9 | 500 | 7.98 |
| 10×2.5 | 22.6 | 23.6 | 650 | 7.98 |
| 12×2.5 | 20.7 | 22.7 | 750 | 7.98 |
| 7×4 | 20 | 22 | 710 | 4.95 |
| 12×4 | 23.5 | 26.5 | 1060 | 4.95 |
9.4 Cables with Ground Conductor (3×…+3×…/3)
| Configuration | Outer Ø min (mm) | Outer Ø max (mm) | Weight (kg/km) | Max Tensile Force (N) |
|---|---|---|---|---|
| 3×50/25 | 38.2 | 41.2 | 2890 | 3000 |
| 3×70/35 | 42.5 | 45.5 | 3750 | 4200 |
| 3×95/50 | 48.3 | 52.3 | 4940 | 5700 |
| 3×120/70 | 54.8 | 58.8 | 6380 | 7200 |
| 3×150/70 | 60.2 | 64.2 | 7660 | 9000 |
| 3×185/95 | 67.3 | 71.3 | 9490 | 11100 |
| 3×240/120 | 72.4 | 76.4 | 11620 | 14400 |
10. Frequently Asked Questions
What does the designation NSSHOEU mean?
The designation follows German cable nomenclature per DIN VDE standards: N = standard type, SS = special rubber with reinforced protection, H = halogen-free or heavy-duty compound, O = without concentric conductor, E = copper screening element, U = rubber outer sheath. The “J” suffix (NSSHOEU-J) indicates inclusion of a green/yellow protective earth conductor, while “O” suffix (NSSHOEU-O) indicates absence of protective earth conductor.
What is the maximum submersible depth for PROTOMONT NSSHOEU cables?
PROTOMONT NSSHOEU cables can be permanently submerged in water up to 2000 meters depth at temperatures up to 40°C. This exceptional depth rating makes them suitable for deep-water mining, pump applications, and industrial water processing systems. At higher water temperatures, reduced service life should be expected.
Can NSSHOEU cables be used in explosive atmospheres?
Yes, PROTOMONT NSSHOEU cables are suitable for use in explosion-hazard areas, subject to local regulations. The cables hold MA-China certification for coal mine safety and MSHA P-189-3 approval for US mining applications. Installation must comply with applicable explosion protection standards (ATEX, IECEx) and be performed by qualified personnel.
What is the difference between NSSHOEU-O and NSSHOEU-J?
NSSHOEU-J cables include a green/yellow protective earth (PE) conductor, making them suitable for applications requiring equipment earthing through the cable. NSSHOEU-O cables do not include this protective earth conductor and are used where earthing is provided through other means or where an earth conductor is not required.
What is the temperature range for flexible operation?
For fully flexible operation (continuous bending and movement), the ambient temperature range is -25°C to +60°C. For fixed installations without movement, the cable can operate in ambient temperatures from -40°C to +80°C. The maximum conductor operating temperature is 90°C for both applications.
Are NSSHOEU cables resistant to oils and chemicals?
Yes, the outer sheath compound (5GM5 per DIN EN 50363) provides excellent resistance to oils and fats per DIN EN 60811-404. The cable also resists many chemicals encountered in mining and industrial environments. However, for aggressive chemicals or unusual substances, resistance properties should be tested prior to installation.
What sizes are available for PROTOMONT NSSHOEU cables?
PROTOMONT NSSHOEU cables are available in a comprehensive range of configurations. Single-core cables range from 16mm² to 400mm². Multi-core options include 2-core through 24-core configurations in cross-sections from 1.5mm² to 240mm². Special configurations with ground conductors (3×…+3×…/3) are available for applications requiring integrated earthing. Special designs can be manufactured upon request.
What certifications does the cable hold for international use?
PROTOMONT NSSHOEU cables hold multiple international certifications including DIN VDE 0250-812 (Germany/EU), MA-China for Chinese coal mine safety applications, MSHA P-189-3 for US mining operations, and EAC Certificate for the Eurasian Economic Union (Russia, Belarus, Kazakhstan, Armenia, Kyrgyzstan). Additional certifications may be available upon request for specific markets.
Contact Anhui Feichun Special Cable Co., Ltd.
For technical inquiries, quotations, or custom cable requirements, please contact our specialist team:
💬 WhatsApp: +86 138 5512 3218Visit our websites: feichuncable.com | feichuncables.com
References and Further Reading
- Reeling Cable – Reeling Cables for Mobile Machinery in Port Terminals and Shipyards
- Amplex Mining Australia – AS/NZS Mining Cables for Australian Mining Operations
- Mining Cable Chile – Mining Cable Solutions for Chile and Peru
- Crane Cable Australia – RoHS Compliance for Crane Cables
- Feichun Cable – Anhui Feichun Special Cable Co., Ltd. Official Website
- DIN Media – DIN VDE 0250-812 Standard Documentation
- Eland Cables – DIN VDE 0250 Standard Cable Information