6491X, 6491B, Twin & Earth, SWA, NYY, NYM – BS 6004/7211/5467/6724 CPR Classified | 固定安裝電纜

What are Fixed Wiring Cables?
6491X, 6491B, Twin & Earth, SWA, NYY, NYM – BS 6004/7211/5467/6724 CPR Classified | 固定安裝電纜
Fixed Wiring Cable Overview | 概述
Fixed wiring cables are the backbone of electrical installations in buildings, designed to be permanently installed in fixed positions—fastened to supports, laid in conduits, or embedded in building structures. Unlike flexible cables used for portable equipment, fixed wiring cables power the essential infrastructure of residential, commercial, and industrial environments: sockets, switches, lighting circuits, distribution boards, and fixed appliances. These cables must comply with the Construction Products Regulation (CPR) for use across Europe, requiring specific fire performance classifications from Aca (highest) to Fca (lowest). The primary choice in fixed wiring is between PVC sheathed cables (economical, general use) and LSZH (Low Smoke Zero Halogen) cables that provide enhanced safety in fire situations by minimizing toxic smoke and corrosive gases.
ESLos cables de instalación fija son la columna vertebral de las instalaciones eléctricas en edificios, diseñados para ser instalados permanentemente en posiciones fijas. Deben cumplir con el Reglamento de Productos de Construcción (CPR) para su uso en toda Europa.
繁中固定佈線電纜是建築物電氣安裝的骨幹,設計用於永久安裝在固定位置——固定在支架上、敷設在導管中或嵌入建築結構中。與用於便攜式設備的柔性電纜不同,固定佈線電纜為住宅、商業和工業環境的基本基礎設施供電:插座、開關、照明電路、配電箱和固定電器。這些電纜必須符合歐洲使用的建築產品法規(CPR),要求從 Aca(最高)到 Fca(最低)的特定防火性能分級。固定佈線的主要選擇是 PVC 護套電纜(經濟實惠,通用)和 LSZH(低煙零鹵素)電纜,後者通過最大限度減少有毒煙霧和腐蝕性氣體,在火災情況下提供增強的安全性。【說明:CPR(建築產品法規)於 2017 年 7 月 1 日在歐盟全面實施,要求所有用於建築的電纜必須具有 CE 標誌和性能聲明(DoP),標明其防火等級】
Fixed wiring cables are manufactured to various national and harmonised standards. British Standards (BS 6004, BS 7211, BS 5467, BS 6724) define cables like Twin & Earth, SWA, and meter tails widely used in UK installations. German VDE/DIN standards specify the NYY, NYM, and NAYY series common throughout Europe. Harmonised standards (H07V, H07Z) enable cross-border specification with consistent designations. For mechanical protection, Steel Wire Armoured (SWA) and Aluminium Wire Armoured (AWA) cables provide robust solutions for direct burial and exposed installations. Many cables carry BASEC (British Approvals Service for Cables) certification, providing independent verification of quality and compliance.
ESLos cables de instalación fija se fabrican según varios estándares nacionales y armonizados. Los estándares británicos definen cables como Twin & Earth y SWA, mientras que los estándares alemanes VDE/DIN especifican las series NYY, NYM y NAYY.
繁中固定佈線電纜按照各種國家和協調標準製造。英國標準(BS 6004、BS 7211、BS 5467、BS 6724)定義了在英國安裝中廣泛使用的 Twin & Earth、SWA 和電表尾線等電纜。德國 VDE/DIN 標準規定了整個歐洲常見的 NYY、NYM 和 NAYY 系列。協調標準(H07V、H07Z)使跨境規格具有一致的標識。對於機械保護,鋼絲鎧裝(SWA)和鋁絲鎧裝(AWA)電纜為直埋和外露安裝提供堅固的解決方案。許多電纜具有 BASEC(英國電纜批准服務機構)認證,提供質量和合規性的獨立驗證。【說明:BASEC 是英國最權威的電纜認證機構,其認證被全球認可為質量和安全的標誌】
PVC vs LSZH Sheathing | PVC 與 LSZH 護套對比
聚氯乙烯——通用固定佈線的傳統經濟選擇。出色的防潮和耐化學性。燃燒時釋放氯化氫(HCl)氣體和濃煙。適用於消防逃生路線清晰且通風良好的大多數住宅和一般商業安裝。
低煙零鹵素——先進化合物,燃燒時產生最少的煙霧且無有毒鹵素氣體。對於密閉空間(醫院、地下、購物中心)必不可少,這些地方煙霧吸入是主要的火災風險。成本較高,但在許多公共建築和逃生路線中被法規強制要求。
CPR Fire Classification System | CPR 防火分級系統
Additional classifications: s1/s2/s3 (smoke emission), d0/d1/d2 (flaming droplets), a1/a2/a3 (acidity). Example: Cca-s1b,d1,a1 | 附加分類:s(煙霧排放)、d(燃燒滴落物)、a(酸度)
British Standard Conduit Wires (6491X/6491B) | 英國標準穿線管電線
6491X and 6491B are single-core insulated building wires designed for installation within conduit, trunking, or enclosed systems. The 6491X (harmonised designations H07V-R for stranded and H07V-U for solid conductor) features PVC insulation and is the traditional choice for general building wiring. The 6491B (harmonised H07Z-R) uses LSZH insulation for applications requiring enhanced fire safety. These cables are not suitable for direct exposure—they must be protected within containment systems. The numerical designation “6491” refers to the British Standard type number, with “X” indicating PVC and “B” indicating LSZH variants.
ES6491X y 6491B son cables de construcción monofásicos aislados diseñados para instalación dentro de conductos, canalizaciones o sistemas cerrados.
繁中6491X 和 6491B 是單芯絕緣建築電線,設計用於在導管、線槽或封閉系統內安裝。6491X(協調標識:絞線為 H07V-R,實心導體為 H07V-U)採用 PVC 絕緣,是一般建築佈線的傳統選擇。6491B(協調標識 H07Z-R)使用 LSZH 絕緣,用於需要增強防火安全的應用。這些電纜不適合直接暴露——必須在容納系統內受到保護。數字標識 “6491” 指的是英國標準類型編號,”X” 表示 PVC,”B” 表示 LSZH 變體。【說明:H07V-R 中的 “R” 表示絞合柔性導體(Class 2),”U” 表示實心剛性導體(Class 1),”K” 表示超柔性導體(Class 5)】
Harmonised Single Core Cables | 協調單芯電纜
| Cable Type 電纜類型 | Voltage 電壓 | Conductor 導體 | Insulation 絕緣 | Temp 溫度 | Application 應用 | SEO |
|---|---|---|---|---|---|---|
| H07V-U | 450/750V | Solid Cu (Class 1) | PVC | 70°C | Rigid conduit wiring 剛性導管佈線 | HIGH |
| H07V-R | 450/750V | Stranded Cu (Class 2) | PVC | 70°C | Flexible conduit wiring 柔性導管佈線 | HIGH |
| H07Z-R | 450/750V | Stranded Cu (Class 2) | LSZH | 70°C | Fire-safe conduit 防火導管 | HIGH |
| H07Z-U | 450/750V | Solid Cu (Class 1) | LSZH | 70°C | Rigid fire-safe 剛性防火 | MEDIUM |
| H05Z-U | 300/500V | Solid Cu (Class 1) | LSZH | 70°C | Light duty fire-safe 輕載防火 | MEDIUM |
| H07G-U | 450/750V | Solid Cu (Class 1) | EPR | 90°C | High temp rigid 高溫剛性 | MEDIUM |
| H07G-R | 450/750V | Stranded Cu (Class 2) | EPR | 90°C | High temp stranded 高溫絞合 | MEDIUM |
| H07G-K | 450/750V | Flexible Cu (Class 5) | EPR | 90°C | High temp flexible 高溫柔性 | MEDIUM |
Meter Tails & Sheathed Cables (6181Y/6181B) | 電表尾線和護套電纜
Meter tails are specialized single-core cables used to connect the electricity meter to the consumer unit (distribution board). The 6181Y is the standard PVC-insulated and sheathed meter tail, typically supplied in 16mm² or 25mm² for domestic installations. The 6181B is the LSZH equivalent for fire-sensitive locations. The 6181XY variant features XLPE insulation with PVC sheath, offering improved current-carrying capacity due to the higher operating temperature of XLPE (90°C vs 70°C for PVC). These cables are colour-coded (brown for live, blue for neutral per BS 7671) and must be installed to DNO (Distribution Network Operator) requirements.
ESLos cables de conexión al medidor son cables de un solo núcleo especializados utilizados para conectar el medidor de electricidad a la unidad de consumidor.
繁中電表尾線是專門的單芯電纜,用於將電表連接到消費者單元(配電箱)。6181Y 是標準的 PVC 絕緣和護套電表尾線,通常為家用安裝提供 16mm² 或 25mm²。6181B 是用於防火敏感位置的 LSZH 等效產品。6181XY 變體採用 XLPE 絕緣和 PVC 護套,由於 XLPE 的較高工作溫度(90°C 對比 PVC 的 70°C),提供了改進的載流能力。這些電纜按顏色編碼(按 BS 7671 標準,棕色為火線,藍色為零線),必須按 DNO(配電網絡運營商)要求安裝。【說明:DNO 是英國負責將電力從國家電網輸送到家庭和企業的區域配電公司,電表尾線的安裝必須符合其特定要求】
Twin & Earth Cables (BS 6004 / BS 7211) | 雙芯加地線電纜
Twin & Earth (also known as “flat twin” or by its product code 624-Y/624-B) is the most common fixed wiring cable for domestic installations in the UK and Ireland. It consists of two insulated conductors (live and neutral) plus a bare or insulated circuit protective conductor (CPC/earth), all enclosed in a flat outer sheath. BS 6004 (624-Y) specifies the PVC version, while BS 7211 (624-B) specifies the LSZH version for fire-sensitive applications. The flat profile allows easy installation beneath plaster, in stud walls, and under flooring. Despite its name, “three-core” versions with an additional switched live are available for two-way lighting circuits.
ESTwin & Earth es el cable de instalación fija más común para instalaciones domésticas en el Reino Unido e Irlanda. Consiste en dos conductores aislados más un conductor de protección de circuito.
繁中Twin & Earth(也稱為 “扁雙芯” 或其產品代碼 624-Y/624-B)是英國和愛爾蘭家用安裝中最常見的固定佈線電纜。它由兩根絕緣導體(火線和零線)加上裸露或絕緣的電路保護導體(CPC/接地線)組成,全部封裝在扁平外護套中。BS 6004 (624-Y) 規定了 PVC 版本,而 BS 7211 (624-B) 規定了用於防火敏感應用的 LSZH 版本。扁平輪廓允許在石膏下、立柱牆內和地板下輕鬆安裝。儘管名稱如此,但還有帶有額外開關火線的 “三芯” 版本,用於雙向照明電路。【說明:Twin & Earth 的地線(CPC)傳統上是裸銅線,但現代版本可能有絕緣地線以符合 BS 7671 第 18 版的規定】
Armoured Cables (SWA/AWA) – BS 5467 / BS 6724 | 鎧裝電纜
Steel Wire Armoured (SWA) and Aluminium Wire Armoured (AWA) cables provide mechanical protection for installations where cables may be subject to impact, crushing, or rodent attack. They are suitable for direct burial, surface mounting, and external installations. BS 5467 specifies PVC-sheathed armoured cables, while BS 6724 specifies LSZH-sheathed versions. SWA (multi-core) uses galvanised steel wire armour applied helically, while AWA (single-core) uses aluminium wire armour to avoid magnetic effects from AC current. The armour can also serve as the circuit protective conductor (CPC) when properly terminated with glands.
ESLos cables armados con alambre de acero (SWA) y armados con alambre de aluminio (AWA) proporcionan protección mecánica para instalaciones donde los cables pueden estar sujetos a impacto o aplastamiento.
繁中鋼絲鎧裝(SWA)和鋁絲鎧裝(AWA)電纜為可能受到衝擊、擠壓或齧齒動物攻擊的安裝提供機械保護。它們適用於直埋、表面安裝和外部安裝。BS 5467 規定了 PVC 護套鎧裝電纜,而 BS 6724 規定了 LSZH 護套版本。SWA(多芯)使用螺旋敷設的鍍鋅鋼絲鎧裝,而 AWA(單芯)使用鋁絲鎧裝以避免交流電流的磁效應。當使用電纜頭正確端接時,鎧裝也可以用作電路保護導體(CPC)。【說明:單芯電纜使用鋁絲鎧裝而非鋼絲鎧裝,是因為交流電流會在鋼鎧裝中產生渦流和磁滯損耗,導致過熱。鋁是非磁性材料,不存在此問題】
| Cable Type 電纜類型 | Standard 標準 | Voltage 電壓 | Armour 鎧裝 | Sheath 護套 | Cores 芯數 | Application 應用 |
|---|---|---|---|---|---|---|
| PVC Sheathed Armoured Cables PVC 護套鎧裝電纜 | ||||||
| BS 5467 SWA PVC Multi-Core | BS 5467 | 0.6/1kV | Steel Wire 鋼絲 | PVC | 2-5 core | General armoured 通用鎧裝 |
| BS 5467 AWA PVC Single-Core | BS 5467 | 0.6/1kV | Aluminium Wire 鋁絲 | PVC | 1 core | Single-core armoured 單芯鎧裝 |
| LSZH Sheathed Armoured Cables LSZH 護套鎧裝電纜 | ||||||
| BS 6724 SWA LSZH Multi-Core | BS 6724 | 0.6/1kV | Steel Wire 鋼絲 | LSZH | 2-5 core | Fire-safe armoured 防火鎧裝 |
| BS 6724 AWA LSZH Single-Core | BS 6724 | 0.6/1kV | Aluminium Wire 鋁絲 | LSZH | 1 core | Fire-safe single-core 防火單芯 |
VDE/DIN German Standard Cables (NYY, NYM, NAYY) | VDE/DIN 德國標準電纜
German VDE (Verband Deutscher Elektrotechniker) standards define the NYY, NYM, and NAYY cable series widely used across Europe. The naming convention is systematic: N=standardised, A=aluminium conductor, Y=PVC insulation, M=PVC sheath (NYM), Y=PVC outer sheath, J=with green/yellow earth core, O=without earth core. NYY-J/O is the direct burial equivalent of British SWA (without armour), while NYM-J/O is the installation cable equivalent of Twin & Earth. NAYY uses aluminium conductors for cost-effective long runs. The NHXMH series provides LSZH alternatives.
ESLos estándares alemanes VDE definen las series de cables NYY, NYM y NAYY ampliamente utilizadas en toda Europa.
繁中德國 VDE(德國電氣工程師協會)標準定義了在整個歐洲廣泛使用的 NYY、NYM 和 NAYY 電纜系列。命名慣例是系統化的:N=標準化,A=鋁導體,Y=PVC 絕緣,M=PVC 護套(NYM),Y=PVC 外護套,J=帶綠/黃接地芯,O=無接地芯。NYY-J/O 是英國 SWA 的直埋等效物(無鎧裝),而 NYM-J/O 是 Twin & Earth 的安裝電纜等效物。NAYY 使用鋁導體進行經濟有效的長距離敷設。NHXMH 系列提供 LSZH 替代品。【說明:VDE 電纜命名系統非常邏輯化——每個字母都有特定含義,一旦理解了這個系統,就可以從電纜名稱直接推斷其結構和特性】
| Cable Type 電纜類型 | Standard 標準 | Voltage 電壓 | Conductor 導體 | Insulation 絕緣 | Sheath 護套 | Application 應用 | SEO |
|---|---|---|---|---|---|---|---|
| Power Installation Cables 電力安裝電纜 | |||||||
| NYY-J / NYY-O | VDE 0276 | 0.6/1kV | Copper 銅 | PVC | PVC | Direct burial / outdoor 直埋/戶外 | VERY HIGH |
| NYM-J / NYM-O | VDE 0250 | 300/500V | Copper 銅 | PVC | PVC | Indoor installation 室內安裝 | VERY HIGH |
| NAYY-J / NAYY-O | VDE 0276 | 0.6/1kV | Aluminium 鋁 | PVC | PVC | Al direct burial 鋁直埋 | HIGH |
| NHXMH-J / NHXMH-O | VDE 0250 | 300/500V | Copper 銅 | XLPE | LSZH | Fire-safe indoor 防火室內 | HIGH |
| Concentric Cables 同心電纜 | |||||||
| NYCY | VDE 0276 | 0.6/1kV | Copper 銅 | PVC | PVC + Cu conc. | Screened power 屏蔽電力 | MEDIUM |
| NYCWY | VDE 0276 | 0.6/1kV | Copper 銅 | PVC | PVC + CuW conc. | Heavy screen power 重型屏蔽電力 | MEDIUM |
| N2XCY | VDE 0276 | 0.6/1kV | Copper 銅 | XLPE | PVC + Cu conc. | XLPE screened 交聯屏蔽 | MEDIUM |
| NA2XCY | VDE 0276 | 0.6/1kV | Aluminium 鋁 | XLPE | PVC + Cu conc. | Al XLPE screened 鋁交聯屏蔽 | MEDIUM |
VDE Cable Naming System | VDE 電纜命名系統
A = Aluminium conductor 鋁導體 (if absent = copper 銅)
Y = PVC insulation PVC 絕緣
2X = XLPE insulation XLPE 絕緣
M = PVC sheath (installation cable) PVC 護套(安裝電纜)
Y = PVC outer sheath PVC 外護套
C = Concentric conductor 同心導體
W = Wire screen 絲網屏蔽
H = Halogen-free 無鹵素
J = With green/yellow earth core 帶綠/黃接地芯
O = Without earth core 無接地芯
Nordic & European Cables (MMJ, MCMK, XVB, XGB) | 北歐和歐洲電纜
Various European countries have developed their own fixed wiring cable standards. Finnish MMJ-HF/MMO-HF cables are halogen-free installation cables widely used in Nordic countries. Swedish MCMK/MCMO cables feature copper concentric conductors for combined earth and screen functions. Belgian XVB-F2/XGB-F2 cables are power cables meeting Belgian and European standards, with XGB being the LSZH variant. The AMCMK is the aluminium conductor version of MCMK for cost-effective longer runs. These regional variants demonstrate how different markets have evolved solutions for their specific installation practices and regulatory requirements.
ESVarios países europeos han desarrollado sus propios estándares de cables de instalación fija. Los cables finlandeses MMJ-HF/MMO-HF son cables de instalación libres de halógenos ampliamente utilizados en países nórdicos.
繁中各個歐洲國家都開發了自己的固定佈線電纜標準。芬蘭 MMJ-HF/MMO-HF 電纜是在北歐國家廣泛使用的無鹵素安裝電纜。瑞典 MCMK/MCMO 電纜具有銅同心導體,用於組合接地和屏蔽功能。比利時 XVB-F2/XGB-F2 電纜是符合比利時和歐洲標準的電力電纜,XGB 是 LSZH 變體。AMCMK 是 MCMK 的鋁導體版本,用於經濟有效的長距離敷設。這些區域變體展示了不同市場如何為其特定的安裝實踐和法規要求演變出解決方案。
| Cable Type 電纜類型 | Origin 產地 | Voltage 電壓 | Conductor 導體 | Sheath 護套 | Feature 特點 | Application 應用 |
|---|---|---|---|---|---|---|
| Finnish Standards 芬蘭標準 | ||||||
| MMJ-HF | Finland 芬蘭 | 300/500V | Copper 銅 | LSZH | Halogen-free + Earth 無鹵素+接地 | Nordic installation 北歐安裝 |
| MMO-HF | Finland 芬蘭 | 300/500V | Copper 銅 | LSZH | Halogen-free no Earth 無鹵素無接地 | Nordic installation 北歐安裝 |
| Swedish Standards 瑞典標準 | ||||||
| MCMK | Sweden 瑞典 | 0.6/1kV | Copper 銅 | PVC | Cu concentric 銅同心 | Swedish power 瑞典電力 |
| MCMO | Sweden 瑞典 | 0.6/1kV | Copper 銅 | PVC | Cu concentric no Earth 銅同心無接地 | Swedish power 瑞典電力 |
| AMCMK | Sweden 瑞典 | 0.6/1kV | Aluminium 鋁 | PVC | Al + Cu concentric 鋁+銅同心 | Cost-effective 經濟型 |
| Belgian Standards 比利時標準 | ||||||
| XVB-F2 | Belgium 比利時 | 0.6/1kV | Copper 銅 | PVC | Belgian standard PVC 比利時標準PVC | Belgian installation 比利時安裝 |
| XGB-F2 | Belgium 比利時 | 0.6/1kV | Copper 銅 | LSZH | Belgian standard LSZH 比利時標準LSZH | Fire-safe Belgian 防火比利時 |
Applications | Aplicaciones | 應用場景
Technical References | 技術參考資料
Contact Us | Contáctenos | 聯繫我們
For technical inquiries, quotations, and specifications for fixed wiring cables including 6491X/6491B conduit wire, Twin & Earth (BS 6004/BS 7211), SWA/AWA armoured cables (BS 5467/BS 6724), NYY/NYM/NAYY German standard cables, and CPR-classified building cables, please contact our engineering and sales teams. We offer BASEC certified and CPR compliant fixed wiring solutions.
ESPara consultas técnicas, cotizaciones y especificaciones de cables de instalación fija incluyendo 6491X/6491B, Twin & Earth, cables armados SWA/AWA y cables NYY/NYM/NAYY, contacte a nuestros equipos.
繁中如需固定佈線電纜(包括 6491X/6491B 穿線管電線、Twin & Earth(BS 6004/BS 7211)、SWA/AWA 鎧裝電纜(BS 5467/BS 6724)、NYY/NYM/NAYY 德國標準電纜以及 CPR 分級建築電纜)的技術諮詢、報價和規格說明,請聯繫我們的工程和銷售團隊。我們提供 BASEC 認證和 CPR 合規的固定佈線解決方案。