What is EN 50288-7 Cable?

Complete Technical Guide to European Standard Instrumentation & Control Cables — RE-2X(st)H, RE-2X(st)Y, RE-2Y(st)Y Series with PiMF/TiMF Screening

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
What is EN 50288-7 Cable? Instrumentation & Control Cable Guide | Feichun Cable

Anhui Feichun Special Cable Co., Ltd.

安徽飞纯特种电缆有限公司

What is EN 50288-7 Cable?

Complete Technical Guide to European Standard Instrumentation & Control Cables — RE-2X(st)H, RE-2X(st)Y, RE-2Y(st)Y Series with PiMF/TiMF Screening

🇪🇺 EN 50288-7 🇬🇧 BS EN 50288-7 ⚡ 300/500V 🛡️ EMI Shielded 🏭 Petrochemical 🔥 Fire Resistant

1. Introduction to EN 50288-7 Instrumentation Cables

EN 50288-7 instrumentation cables are multi-element metallic cables used in analogue and digital communication and control applications. Manufactured in accordance with European Standard EN 50288 (British Standard BS EN 50288), these cables are widely used in processing plants such as those found in the petrochemical industry due to their ability to withstand electromagnetic interference (EMI). They are specifically designed for the transmission of signals in instrumentation, control, and communication applications, commonly available in 300V and 500V voltage ratings.

Part 1 of EN 50288 covers the generic specification of multi-element metallic cables used in analogue and digital communication and control. These cables are generally used for instrumentation, inter-connection of equipment, and information technology cabling applications. Part 7 of this same standard sets out the sectional specification for instrumentation and control cables. This European Standard was approved by CENELEC (European Committee for Electrotechnical Standardization), and its members are bound by agreement to give it the status of national standard, which is why the British standard reference is BS EN 50288-7.

🏭 EN 50288-7 Application Areas

Petrochemical Plants

Refineries, chemical plants
Natural gas terminals

Process Control

Analogue/digital signals
4-20mA loops

Power Generation

Power stations
Energy infrastructure

Industrial Automation

Cement factories
Manufacturing plants

Source: Eland Cables – EN 50288 Standard Cable

EspañolIntroducción a los Cables de Instrumentación EN 50288-7

Los cables de instrumentación EN 50288-7 son cables metálicos multielemento utilizados en aplicaciones de comunicación y control analógico y digital. Fabricados de acuerdo con la Norma Europea EN 50288 (Norma Británica BS EN 50288), estos cables se utilizan ampliamente en plantas de procesamiento como las que se encuentran en la industria petroquímica debido a su capacidad para resistir las interferencias electromagnéticas (EMI). Están específicamente diseñados para la transmisión de señales en aplicaciones de instrumentación, control y comunicación, comúnmente disponibles en clasificaciones de voltaje de 300V y 500V.

繁體中文EN 50288-7 儀表電纜簡介

EN 50288-7儀表電纜是用於模擬和數位通訊及控制應用的多元件金屬電纜。這些電纜按照歐洲標準EN 50288(英國標準BS EN 50288)製造,由於其能夠承受電磁干擾(EMI),在石油化工行業等加工廠中廣泛使用。它們專門設計用於儀表、控制和通訊應用中的信號傳輸,通常提供300V和500V電壓等級。EN 50288第1部分涵蓋用於模擬和數位通訊及控制的多元件金屬電纜的通用規範。這些電纜通常用於儀表、設備互連和信息技術佈線應用。該標準第7部分規定了儀表和控制電纜的分部規範。此歐洲標準由CENELEC(歐洲電工標準化委員會)批准,其成員根據協議有義務將其作為國家標準。

2. EN 50288-7 Cable Nomenclature Decoder

BS EN 50288-7 cables are known by their construction — straightforward when you understand the abbreviations. The cable designation system provides a complete description of the cable’s insulation, screening, and sheath materials in a standardized format. Understanding this nomenclature is essential for correct cable specification in instrumentation and control applications.

🔧 EN 50288-7 Cable Code Decoder

Code ElementMeaningOptions
RECable TypeInstrumentation & Control Cable
TFire BarrierMica glass tape (fire resistant)
2XInsulationXLPE Cross-linked Polyethylene
2YInsulationPE Polyethylene
YInsulationPVC Polyvinyl Chloride
(st)Screen TypeAluminium/Polyester tape with drain wire
HOuter SheathLSZH Low Smoke Zero Halogen
YOuter SheathPVC Polyvinyl Chloride
SWAArmourSWA Steel Wire Armour
PiMFScreeningPairs in Metal Foil Individual + Collective
TiMFScreeningTriples in Metal Foil Individual + Collective

Source: Eland Cables – Specifying BS EN 50288-7

Example Cable Designations

Understanding the nomenclature system allows you to decode any EN 50288-7 cable. For instance, RE-2X(st)H indicates an instrumentation cable with XLPE insulation (2X), aluminium/polyester tape screen with drain wire (st), and LSZH sheath (H). Adding PiMF indicates individually and collectively screened pairs in metal foil. An armoured cable with PE insulation and PVC inner and outer sheath would be designated RE-2Y(st)Y SWAY.

3. RE-2X(st)H XLPE LSZH Instrumentation Cable

RE-2X(st)H cables are low smoke zero halogen instrumentation cables with screening to provide signal integrity against electromagnetic interference. These cables’ LSZH properties make them suitable for use in environments where smoke and toxic fumes would pose a risk to human life and sensitive equipment in the event of a fire. Manufactured in accordance with EN 50288, these cables are widely used in the petrochemical industry in instrumentation and control applications with a 300/500V voltage rating for analogue and digital signal transmission.

🟢 RE-2X(st)H LSZH Cable Construction
StandardEN 50288-7 BS EN 50288-7
Voltage Rating300/500V
Conductor (0.5-0.75mm²)Class 5 Flexible Copper
Conductor (≥1mm²)Class 2 Stranded Copper
InsulationXLPE Cross-linked Polyethylene
Individual ScreenAluminium/Polyester Tape (24µm)
Drain WireTinned Copper 0.5mm²
Collective ScreenAluminium/PET + 7-strand TC drain wire
Outer SheathLSZH Low Smoke Zero Halogen
Sheath ColoursBlack (UV) or Blue (IS)
Flame RetardantIEC/EN 60332-1-2, IEC/EN 60332-3-24
Low SmokeIEC/EN 60754-1/2, IEC/EN 61034-1/2

Source: Eland Cables – RE-2X(st)H Cable

RE-2X(st)H Variants

Cable ModelScreen TypeArmourApplication
XLPE Insulated / LSZH Sheathed
RE-2X(st)H LSZHOS CollectiveNoneFire-safe areas
RE-2X(st)H LSZH PiMFPiMF Ind+CollNoneHigh EMI areas
RE-2X(st)H SWAH LSZHOS CollectiveSWAUnderground
RE-2X(st)H SWAH PiMFPiMF Ind+CollSWARefineries

4. RE-2X(st)Y XLPE PVC Instrumentation Cable

RE-2X(st)Y cables are XLPE insulated and PVC sheathed instrumentation cables manufactured in accordance with European standard EN 50288-7. These multi-element metallic cables are designed for the transmission of analogue and digital signals in instrumentation, control, and communications applications with a voltage rating of 300/500V. The XLPE insulation provides excellent electrical properties and thermal stability, while the PVC sheath offers robust mechanical protection and resistance to oils, acids, and alkalis.

🔵 RE-2X(st)Y XLPE PVC Cable Construction
StandardEN 50288-7
Voltage Rating300V
ConductorClass 5 (0.5-0.75mm²) / Class 2 (≥1mm²) Copper
InsulationXLPE (EN 50290-2-29)
ElementsPairs (twisted) / Triples (twisted)
ScreenAl/PET tape + Tinned Copper drain wire
Outer SheathPVC (EN 50290-2-22)
Flame RetardantIEC/EN 60332-1-2, IEC/EN 60332-3-24

Source: Eland Cables – RE-2X(st)Y Cable

RE-2X(st)Y Applications

RE-2X(st)Y cables are recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations. They are not recommended for direct burial without armour protection. The XLPE insulation provides superior dielectric properties compared to PVC, making these cables suitable for applications requiring high signal integrity and resistance to temperature variations.

5. RE-2Y(st)Y PE PVC Instrumentation Cable

RE-2Y(st)Y cables are PE insulated and PVC sheathed instrumentation cables manufactured in accordance with British and European standard BS EN 50288. These multi-element metallic cables are designed for signal transmission in instrumentation, analogue and digital communication, and control applications in process plants such as those found in the petrochemical industry. The PE insulation offers excellent electrical properties with low dielectric loss.

🔴 RE-2Y(st)Y PE PVC Cable Construction
StandardEN 50288-7
Voltage Rating300V (90V and 500V available)
ConductorClass 5 (0.5-0.75mm²) / Class 2 (≥1mm²) Copper
InsulationPE Polyethylene
ElementsPairs and Triples configurations
Individual ScreenAl/PET tape (PiMF/TiMF variants)
Collective ScreenAl/PET tape + drain wire
Inner SheathPVC
Armour (optional)SWA
Outer SheathPVC
Max Operating Temp75°C

Source: Eland Cables – RE-2Y(st)Y Cable

RE-2Y(st)Y Variants

Cable ModelScreen TypeArmourApplication
PE Insulated / PVC Sheathed
RE-2Y(st)Y PVCOS CollectiveNoneIndoor/Outdoor
RE-2Y(st)Y PVC PiMFPiMF Ind+CollNoneHigh precision
RE-2Y(st)Y SWAY PVCOS CollectiveSWAUnderground
RE-2Y(st)Y SWAY PVC PiMFPiMF Ind+CollSWARefineries

6. Screening Configurations Explained

EN 50288-7 cables are available in a number of variants according to their specific applications. The screen plays a key role in protecting signals from interference. While overall screens (OS/St) offer general EMI shielding, PiMF (Pair in Metal Foil) and TiMF (Triad in Metal Foil) constructions shield each pair or triad individually, making them ideal for high-precision and noise-sensitive environments. Individual screening prevents crosstalk between signal pairs within the same cable.

🛡️ Screening Configuration Comparison
Screen TypeCodeConfigurationEMI ProtectionApplication
Overall Screen(st) / OSCollective onlyStandardGeneral instrumentation
Pairs in Metal FoilPiMFIndividual + CollectiveHighHigh EMI environments
Triples in Metal FoilTiMFIndividual + CollectiveHigh3-wire applications
Collective Aluminium MylarCAMAl/Mylar tapeStandardCost-effective
Individual + CollectiveICAMBoth layersMaximumCritical signals

When to Use PiMF/TiMF Screening

The individual screening of each pair limits the consequence of crosstalk and provides superior protection against electromagnetic interference by individually shielding each pair and triad with metal foil. This feature is critically important for maintaining signal integrity and ensuring uninterrupted signal transmission in environments with high levels of electromagnetic interference, such as near motors, inverters, and power cables that often create noise and signal distortion.

Source: ETK Kablo – What Are Instrumentation Cables

7. Fire Resistant & Intrinsically Safe Variants

Some cables manufactured in accordance with EN 50288 are suitable for use in intrinsically safe systems, in which case their outer sheath is blue. The blue outer sheath is the most popular standard for IS cables in the industry, making it easier for maintenance personnel to find inherently safe circuits during inspections. Fire resistant variants are also available with a Mica tape protecting the conductors to provide circuit integrity.

🔥 Fire Resistant Cable Construction (RE-T2X(st)H)

For additional fire protection, RE-2X(st)H cables can have a layer of mica glass tape added to the insulating layer. These cables are designated RE-T2X(st)H and RE-T2X(st)H SWAH. The mica tape provides a fire barrier that maintains circuit integrity when exposed to fire, allowing continued signal transmission during emergency situations.

Fire BarrierMica glass tape
Fire ResistanceIEC 60331 (circuit integrity)
Flame RetardantIEC 60332-1 or IEC 60332-3-24(C)
ApplicationEmergency circuits, safety systems

Source: Nexans – EN 50288-7 Fire Resistant Cable

Intrinsically Safe (Blue Sheath) Cables

This range of cables is available with a blue or black outer sheath colour. The blue denotes an ex-proof (intrinsically safe) connection in explosive and in flammable environments. Black sheathed cables are resistant to ultraviolet (UV) light. EN 50288-7 cables are allowed for use in Zone 1 and Zone 2, Group II, classified areas according to IEC 79-14, but are not allowed for direct connection to low impedance sources such as public mains electricity supply.

Sheath ColourApplicationFeatures
BlueIntrinsically Safe (IS) systemsATEX Zone 1/2, explosive atmospheres
BlackStandard / UV exposedUV resistant, outdoor installation

8. EN 50288-7 Cable Construction Specification

Complete Construction Reference

ComponentSpecification
ConductorSolid, stranded, or flexible plain or metal coated copper (Class 1, 2, or 5) per IEC 60228
InsulationPVC, PE, or XLPE (per EN 50290-2-29)
Core ElementsPair (twisted), Triple (twisted), Quad (twisted)
Twisting Lay Length100-150mm depending on conductor size
Individual ScreenLaminated tape aluminium/PET, total thickness 24µm
Drain WireSolid tinned copper 0.6mm Ø under individual screen
Collective Screen24µm Al/PET tape + 7-strand tinned copper drain wire (0.5mm²), foil overlap min 20%
Inner SheathPVC, PE, or LSZH
Metal Braid (optional)Tinned copper wires, wire diameter ≥0.3mm, filling factor ≥0.57mm
ArmouringSWA (Steel Wire Armour), Flat steel wires, Steel or Brass Tape
Outer SheathPVC, PE, or LSZH

9. Technical Specifications

Voltage Rating

300/500V
Standard ratings

Max Temp (XLPE)

90°C
Continuous operation

Max Temp (PE)

75°C
Continuous operation

Min Bending Radius

6×OD
Unarmoured / OS

Electrical Characteristics

ParameterValueStandard
Voltage Rating300V / 500VEN 50288-7
Test Voltage2000V AC (1 minute)EN 50288-1
Insulation Resistance≥100 MΩ·kmEN 50288-1
Max Operating Temp (XLPE)90°CEN 50290-2-29
Max Operating Temp (PE)75°CEN 50290-2-20
Max Operating Temp (PVC)70°CEN 50290-2-21
Min Installation Temp-5°C (standard) / -40°C (special)EN 50288-7
Min Bending Radius (unarmoured)6 × overall diameterEN 50288-7
Min Bending Radius (armoured)12 × overall diameterEN 50288-7
Conductor Sizes0.5mm² to 2.5mm²IEC 60228

10. Complete EN 50288-7 Cable Model Comparison

Cable Selection Guide

Cable ModelInsulationSheathArmourScreenApplication
XLPE Insulated / LSZH Sheathed (RE-2X(st)H Series)
RE-2X(st)H LSZHXLPELSZHNoneOSFire-safe
RE-2X(st)H LSZH PiMFXLPELSZHNonePiMFHigh EMI
RE-2X(st)H SWAH LSZHXLPELSZHSWAOSUnderground
RE-2X(st)H SWAH PiMFXLPELSZHSWAPiMFRefineries
XLPE Insulated / PVC Sheathed (RE-2X(st)Y Series)
RE-2X(st)Y PVCXLPEPVCNoneOSStandard
RE-2X(st)Y PVC PiMFXLPEPVCNonePiMFHigh EMI
PE Insulated / PVC Sheathed (RE-2Y(st)Y Series)
RE-2Y(st)Y PVCPEPVCNoneOSStandard
RE-2Y(st)Y SWAY PVCPEPVCSWAOSUnderground
RE-2Y(st)Y SWAY PVC PiMFPEPVCSWAPiMFRefineries

Authoritative External References

●
Eland Cables – EN 50288 Standard Cable
https://www.elandcables.com/…/bs-en-50288-cable
●
Eland Cables – RE-2X(st)H Cable
https://www.elandcables.com/…/re-2x-st-h-cable
●
Eland Cables – RE-2X(st)Y Cable
https://www.elandcables.com/…/re-2x-st-y-cable
●
Eland Cables – RE-2Y(st)Y Cable
https://www.elandcables.com/…/re-2y-st-y-cable
●
Eland Cables – Specifying BS EN 50288-7
https://www.elandcables.com/…/specifying-bs-en-50288-7
●
ETK Kablo – What Are Instrumentation Cables
https://www.etkkablo.com/…/what-are-instrumentation-cables
●
Nexans – EN 50288-7 Fire Resistant Cable
https://www.nexans.de/…/EN_50288_7_Fire_resistant
●
Eland Cables – Instrumentation Cable
https://www.elandcables.com/…/instrumentation-cable
●
Caledonian Cables – EN 50288-7 Instrumentation
http://www.caledoniancable.com/…/EN50288-7
●

Contact Feichun Cable

For technical support with EN 50288-7 instrumentation cables, PiMF/TiMF screening configurations, fire resistant variants, or petrochemical applications, please contact our engineering team.

📱
📧

Technical Support

[email protected]
👤

Sales – Mr. Zihao Yang

[email protected]
👤

Sales – Mr. Ziyu Huang

[email protected]

Anhui Feichun Special Cable Co., Ltd. | 安徽飞纯特种电缆有限公司

Professional Manufacturer of EN 50288-7 Instrumentation & Control Cables

© 2025 Feichun Cable. All rights reserved.

Previous Article

What is 19/33kV Cable?

Next Article

What is CSA 22.2 No. 210-11 Cable?

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注