What is Type 14 BS 6708 Trailing Cable?

Three phase cores with composite individual screens, one unscreened pilot core and one unscreened earth core laid up around an elastomeric cradle and in contact with each other

Type 14 BS 6708 Trailing Cable
Type 14 BS 6708 Trailing Cable
What is Type 14 BS 6708 Trailing Cable? Technical Specifications | Feichun Cables
ANHUI FEICHUN SPECIAL CABLE CO., LTD. TYPE 14

What is Type 14 BS 6708 Trailing Cable?

Three phase cores with composite individual screens, one unscreened pilot core and one unscreened earth core laid up around an elastomeric cradle and in contact with each other

Turkish Translation: Kompozit bireysel ekranlı üç faz damarı ile ekransız bir kumanda ve bir toprak damarı elastomer fitil etrafında birbirlerine temas edecek şekilde bükülür.

Introduction to BS 6708 Type 14 Trailing Cable

The BS 6708 Type 14 Trailing Cable represents a specialized engineering solution within the British Standard family of mining cables, specifically designed for power distribution to excavating and crushing machines in underground coal mines and surface quarrying operations. This cable type features a unique configuration that balances electromagnetic protection with cost efficiency and simplified installation.

🔑 Critical Distinguishing Feature

Unlike Type 11 cables where all cores are screened, Type 14 features screened phase cores only, with the pilot core and earth core intentionally left unscreened. This design choice provides specific advantages in fault current handling and cable weight optimization while maintaining essential EMI protection for power conductors.

According to BS 6708:1998 classification, Type 14 belongs to the family of non-armoured cables with individually metallic screened cores rated at 640/1100 V, specifically designated for use with coalface cutters and similar mining machinery. The standard encompasses Types 7, 7M, 7S, 11, 14, and 16, each with distinct screening configurations optimized for specific operational requirements.

Configuration Summary:

  • Phase Cores: 3 cores with composite tinned copper/nylon braided screens
  • Pilot Core: 1 unscreened core for monitoring/control functions
  • Earth Core: 1 unscreened core for fault current path
  • Lay-up: All cores in contact around elastomeric cradle

As documented by the Tratos Group BS 6708 Standard Overview, Type 14 cables are engineered for environments where explosive gases and dust accumulate, requiring cables that minimize ignition risks while delivering substantial electrical power to heavy mining equipment.

Source: BS 6708:1998 Flexible cables for use at mines and quarries – ICS Category 29.260.20 Electrical apparatus for explosive atmospheres. en-standard.eu

Key Differences: Type 14 vs Type 11 Configuration

Screening Architecture Comparison

Understanding the screening differences between Type 14 and Type 11 is essential for proper cable selection in mining applications. These differences directly impact electromagnetic compatibility, fault current management, and installation complexity.

FeatureType 14Type 11Implication
Phase Core Screening✓ Screened (3 cores)✓ Screened (3 cores)Both provide EMI protection for power conductors
Pilot Core Screening✗ Unscreened✓ ScreenedType 11 offers better monitoring signal protection
Earth Core✓ Dedicated unscreened coreIntegrated with pilot screeningType 14 has separate dedicated earth path
Core Configuration3×Phase + 2×Auxiliary3×Phase + 1×PilotType 14 has additional earth core
Typical Sizes25-95 mm² phase16 mm² standardType 14 for higher power applications
Cable Weight3,550-9,800 kg/km~1,960 kg/kmType 14 heavier due to larger conductors
Type 14 Cross-Section Configuration:

[SCREENED PHASE 1] ○ [SCREENED PHASE 2] ○ [SCREENED PHASE 3]
        ●                ●                ●
        Cu/Nylon Braid      Cu/Nylon Braid      Cu/Nylon Braid

[UNSCREENED PILOT CORE] ◇ [UNSCREENED EARTH CORE]
              NO SCREEN              NO SCREEN

All cores laid up around ELASTOMERIC CRADLE

Advantages of Type 14 Unscreened Auxiliary Cores

Technical Benefits:

  • Lower Fault Impedance: Unscreened earth core provides direct, low-impedance path for fault currents without screening resistance interference
  • Reduced Cable Complexity: Simpler termination procedures for auxiliary cores without screen bonding requirements
  • Cost Optimization: Lower material costs for larger cross-section applications (25-95 mm²)
  • Enhanced Fault Current Capacity: Earth conductor sized independently for optimal fault current handling (up to 7,300 A for 1 second)
  • Weight Efficiency: Marginal weight savings compared to fully screened configuration

When to Select Type 14 Over Type 11

Type 14 cables are the optimal choice for applications requiring:

  • Higher power ratings (110A to 250A continuous current)
  • Longer cable runs with larger conductor cross-sections
  • Simplified earth continuity management
  • Applications where pilot core EMI protection is less critical
  • Systems with independent earth monitoring requirements
Technical Reference: Understanding screening configurations in mining cables – Amplex Mining Cable Solutions

Purpose and Primary Applications

Core Operational Functions

BS 6708 Type 14 cables serve as critical power supply infrastructure for coalcutters and other machines operating in challenging mining environments. The cable’s configuration with three screened phase conductors plus unscreened pilot and earth cores provides optimized power delivery for high-demand applications.

Rated Voltage (U₀/U)
640/1100
Volts AC
Test Voltage
3
kV AC
Maximum Current (95mm²)
250
Amperes Continuous
Short Circuit Rating (1s)
7,300
Amperes

Primary Equipment Applications

Heavy Excavating Machinery

Type 14 cables excel in powering continuous mining machines, roadheaders, and longwall shearers that require substantial electrical power (110-250A continuous) for their cutting heads and material handling systems. The larger conductor cross-sections (25-95 mm²) accommodate the high current demands of these power-intensive machines.

Crushing and Processing Equipment

Mobile crushing units operating in underground and surface mining environments require the robust power delivery capabilities of Type 14 cables. The heavy-duty chloroprene outer sheath withstands the abrasive conditions typical in crushing operations.

Environmental Deployment Zones:

  • Deep Underground Mines: Explosive gas atmospheres (methane, coal dust)
  • Surface Quarrying: Exposed to weather extremes and mechanical stress
  • Hybrid Operations: Transitional zones between underground and surface facilities

Power Transmission Capabilities

According to research documented by Reeling Cable Technology Solutions, trailing cables serve as critical lifelines for mobile mining equipment, delivering electrical power while accommodating continuous movement. Type 14 cables specifically address the power density requirements of larger mining equipment through their optimized conductor sizing.

Cable SizeContinuous Current @ 25°C1s Short Circuit CurrentTypical Application
3×25+2×16 mm²110 A3,450 ALoading machines, auxiliary equipment
3×35+2×16 mm²135 A3,450 AMedium continuous miners
3×50+2×25 mm²170 A4,550 ALarge continuous miners
3×70+2×35 mm²205 A4,820 AHigh-power roadheaders
3×95+2×50 mm²250 A7,300 AHeavy-duty longwall equipment
Application Reference: Mining cable applications for cutting machines – reelingcable.com

Cable Construction and Material Structure

Seven-Layer Construction Architecture

BS 6708 Type 14 cables employ a sophisticated seven-layer construction system where each component is engineered to serve specific functions critical for mining environment performance.

LayerMaterialSpecificationFunction
1. ConductorElectrolytic Tinned CopperIEC 60228 Class 5 StrandedMaximum conductivity with corrosion resistance and flexibility
2. InsulationEPR (Ethylene Propylene Rubber)High dielectric strength compoundElectrical isolation with temperature stability (-40°C to +90°C)
3. SeparatorColored Textile TapeCore identification colorsPhase identification (Black, Grey, Brown; Blue pilot)
4. ScreenTinned Copper/Nylon BraidPhase cores ONLY screenedEMI shielding for power conductors; pilot/earth unscreened
5. Lay-upElastomeric Cradle ConfigurationAll cores in contactMechanical stability during flexing operations
6. BeddingRubber-Based CompoundCushioning filler materialInternal protection and shape maintenance
7. Outer SheathHeavy-Duty Chloroprene (PCP)Flame retardant elastomerEnvironmental, mechanical, and chemical protection

Conductor Technology: IEC 60228 Class 5 Compliance

The conductor system utilizes electrolytic copper processed through fine stranding to achieve IEC 60228 Class 5 flexibility ratings. According to international standards documentation, Class 5 conductors are specifically intended for flexible cables where repeated bending is required.

Stranding Configurations by Size:

Cross Section (mm²)StrandingWire Diameter (mm)Nominal Conductor Diameter (mm)
16126/0.400.405.50
25196/0.400.406.75
35276/0.400.408.00
50396/0.400.409.75
70360/0.500.5011.60
95475/0.500.5012.75

The tinning process applied to all copper conductors provides enhanced corrosion resistance critical for mining environments. According to EPR Cable Technology research, tinned conductors exhibit superior long-term performance in humid and chemically aggressive atmospheres typical of underground mining operations.

EPR Insulation System Properties

Ethylene Propylene Rubber (EPR) insulation provides exceptional electrical and mechanical properties essential for mining cable applications. According to Eland Cables technical documentation, EPR offers high dielectric strength with a wide thermal range typically from -55°C to 150°C.

Insulation Thickness (25mm²)
1.6
mm (Phase cores)
Insulation Thickness (95mm²)
2.0
mm (Phase cores)
Dielectric Strength
High
Superior water tree resistance

Composite Screen Construction

The tinned copper/nylon braided screen over phase cores provides:

  • Electromagnetic Interference Shielding: Prevents interference between power circuits and nearby control systems
  • Fault Current Path: Additional parallel path for earth fault currents
  • Mechanical Protection: Braided construction maintains flexibility while protecting insulation

Total Screen Cross Section by Cable Size:

  • 3×25+2×16: 25.4 mm²
  • 3×35+2×16: 25.4 mm²
  • 3×50+2×25: 33.0 mm²
  • 3×70+2×35: 35.0 mm²
  • 3×95+2×50: 53.0 mm²

Heavy-Duty Chloroprene Outer Sheath

The outer sheath utilizes chloroprene (polychloroprene/neoprene) compound selected for its exceptional resistance properties in mining environments. The radial thickness increases with cable size to provide proportional protection:

Cable SizeOuter Sheath Radial ThicknessMin Overall DiameterMax Overall Diameter
3×25+2×165.0 mm43.2 mm46.6 mm
3×35+2×165.2 mm47.3 mm50.7 mm
3×50+2×255.7 mm53.7 mm57.6 mm
3×70+2×356.3 mm61.2 mm65.0 mm
3×95+2×507.0 mm69.3 mm73.9 mm
Material Reference: Chloroprene sheath properties for mining cables – tratosgroup.com

Complete Technical Specifications

Comprehensive Parameter Table – All Type 14 Configurations

The following detailed specifications cover all standard BS 6708 Type 14 cable sizes, providing essential engineering data for system design, cable selection, and installation planning.

Parameter3×25+2×163×35+2×163×50+2×253×70+2×353×95+2×50Unit
Phase Conductor Data
Number × Cross Section3×253×353×503×703×95mm²
Stranding196/0.40276/0.40396/0.40360/0.50475/0.50wires/mm
Conductor Diameter6.758.009.7511.6012.75mm (nom)
Insulation Thickness1.61.61.71.82.0mm
Total Screen Cross Section25.425.433.035.053.0mm²
Earth Conductor (Unscreened)
Cross Section1×161×161×251×351×50mm²
Stranding126/0.40126/0.40196/0.40276/0.40396/0.40wires/mm
Conductor Diameter5.505.506.758.009.75mm (nom)
Insulation Thickness1.61.61.71.82.0mm
Pilot Conductor (Unscreened)
Cross Section1×251×351×501×701×95mm²
Stranding196/0.40276/0.40396/0.40360/0.50475/0.50wires/mm
Conductor Diameter6.758.009.7511.6012.75mm (nom)
Insulation Thickness1.51.51.61.61.7mm
Overall Cable Properties
Min Overall Diameter43.247.353.761.269.3mm
Max Overall Diameter46.650.757.665.073.9mm
Min Bending Radius420457519585666mm
Outer Sheath Radial Thickness5.05.25.76.37.0mm
Max Pulling Tension6387299101,1481,446kgf
Approximate Cable Weight3,5504,2805,6507,5209,800kg/km
Copper Weight1,3071,6752,3403,2284,326kg/km
Data Source: BS 6708 Type 14 Cable Specifications – FR 074-2014 REV. 0, dated 29.01.2011

Electrical Performance Parameters

Current Carrying Capacity and Resistance Values

The electrical characteristics of BS 6708 Type 14 cables are optimized for high-power mining equipment operation, with careful attention to conductor resistance, current ratings, and fault current withstand capabilities.

Electrical Parameter3×25+2×163×35+2×163×50+2×253×70+2×353×95+2×50Unit
Continuous Current Rating @ 25°C110135170205250A
Short Circuit Current (1 second)3,4503,4504,5504,8207,300A
Max DC Resistance @ 20°C (Phase/Earth)0.7950.5650.3930.2770.210Ω/km
Max DC Resistance @ 20°C (Pilot)1.2401.2400.7950.5650.393Ω/km
Screen Resistance (3 parallel)1.101.201.400.700.85Ω/km

Short Circuit Current Analysis

The short circuit current ratings for Type 14 cables are calculated based on adiabatic heating assumptions according to IEC 60949 methodology. According to ScienceDirect Engineering research, ratings are typically assessed over one-second duration with conductor temperature not exceeding 250°C for EPR-insulated cables.

Short Circuit Calculation Formula:

I = k × S / √t

Where:
I = Short-circuit current (A)
k = Material constant for copper-EPR (typically 143 A·s0.5/mm²)
S = Conductor cross-sectional area (mm²)
t = Fault duration (seconds)

Example for 95mm² conductor:
I = 143 × 95 / √1 = 13,585 A theoretical
Actual rating: 7,300 A (conservative with safety factor)

Voltage Drop Considerations

For long cable runs typical in mining operations, voltage drop calculations are critical for system design. Using the resistance values provided:

Voltage Drop Calculation Example (3×95+2×50 at 250A, 100m):

Phase conductor resistance: 0.210 Ω/km
For 100m: 0.210 × 0.1 = 0.021 Ω

Three-phase voltage drop = √3 × I × R × cos(φ)
Assuming cos(φ) = 0.85:
ΔV = 1.732 × 250 × 0.021 × 0.85 = 7.73 V

Percentage of 640V phase voltage: 1.21% (Well within acceptable limits)

Earth Fault Current Path Analysis

Type 14’s unscreened earth core provides a direct, low-impedance path for earth fault currents. The combined earth path includes:

Cable SizeEarth Core Resistance (Ω/km)3 Screens Parallel (Ω/km)Combined Parallel Path (Ω/km)
3×25+2×160.7951.100.461
3×35+2×160.5651.200.384
3×50+2×250.3931.400.307
3×70+2×350.2770.700.198
3×95+2×500.2100.850.168
Calculation Reference: Short circuit current calculations for mining cables – MSHA Technical Support

Compliance with International Standards

Primary Standard: BS 6708:1998

BS 6708 Type 14 cables comply with the British Standard BS 6708:1998 “Flexible cables for use at mines and quarries.” This comprehensive standard, classified under ICS 29.260.20 (Electrical apparatus for explosive atmospheres), establishes stringent requirements for cable construction, testing, and performance in hazardous mining environments.

BS 6708 Type 14 Classification:

  • Category: Non-armoured cables with individually metallic screened cores
  • Rated Voltage: 640/1100 V
  • Test Voltage: 3 kV AC
  • Application Group: Coalface cutters and similar machines
  • Screening Configuration: Phase cores screened; pilot and earth cores unscreened

Referenced Standards and Specifications

StandardTitle/ScopeApplication to Type 14
IEC 60228Conductors of insulated cablesClass 5 flexible conductor requirements
IEC 60724Short-circuit temperature limits250°C max for EPR insulated cables
IEC 60949Short-circuit current ratingsAdiabatic calculation methodology
BS 7655-1.290°C application elastomeric compoundsEPR insulation material specifications
BS 7655-2.3Sheathing compoundsChloroprene outer sheath requirements
EN/IEC 60332-1-2Flame retardance testingSingle vertical flame propagation test
BCS 188:1978British Coal SpecificationHistorical reference for trailing cables

Quality Assurance Testing Regime

Type 14 cables undergo comprehensive factory testing to verify compliance with BS 6708 requirements:

Routine Test: Voltage Withstand
3 kV
AC for 5 minutes on phase cores
Insulation Resistance
>100
MΩ·km at 20°C (minimum)
Conductor Resistance
Pass
As per IEC 60228 Class 5

Certifications and Approvals

BS 6708 Type 14 cables may carry additional certifications depending on deployment region:

  • ATEX Directive 2014/34/EU: For European explosive atmosphere applications
  • MSHA (USA): Mine Safety and Health Administration approval
  • MA (China): Coal mine safety certification
  • SANS 1520: South African mining cable standards
Standards Reference: BS 6708:1998 complete requirements – GlobalSpec Standards Database

Comparison: BS 6708 Type 14 vs VDE 0250 Part 812

Standards Overview

Both British Standard BS 6708 and German Standard DIN VDE 0250 represent internationally recognized frameworks for mining and industrial flexible cable specifications. DIN VDE 0250 Part 812 specifically governs EPR insulated flexible cables designated NSSHÖU, while BS 6708 Type 14 addresses mining trailing cables with specific screening configurations.

According to Eland Cables VDE expertise, Germany is the only country to have issued special design regulations for flexible electrical cables covering cranes and material handling equipment, making DIN VDE 0250 globally recognized as the ultimate standard for tough rubber sheathed flexible cables.

ParameterBS 6708 Type 14VDE 0250-812 (NSSHÖU)Technical Analysis
Rated Voltage640/1100 V450/750 VBS 6708 superior for HV mining equipment
Test Voltage3 kV2.5 kV typicalBS 6708 higher safety margin
Primary ApplicationUnderground coal mining with explosive atmospheresGeneral industrial, tunneling, miningType 14 more specialized
Conductor ClassIEC 60228 Class 5DIN EN 60228 / VDE 0295 Class 5Equivalent flexibility
Insulation MaterialEPREPR or equivalent elastomerSame base material
Screening ConfigurationPhase cores only (Pilot/Earth unscreened)Various options (screened/unscreened)Type 14 optimized earth path
Dedicated Earth CoreYes (separate unscreened)Configuration dependentType 14 better fault current management
Outer SheathHeavy-duty chloroprene (PCP)Polychloroprene or equivalentComparable protection
Temperature Range-40°C to +85°C ambient-25°C to +60°C flexible useType 14 wider range for deep mines
Short Circuit Temperature250°C (1 second)250°C (short circuit)Equivalent thermal performance
Current Ratings (Example)110-250 A (25-95mm²)Variable by configurationType 14 higher power density
Explosive Atmosphere DesignSpecifically for gassy minesGeneral hazardous areasType 14 methane-specific

Key Advantages of BS 6708 Type 14

Technical Superiorities:

  • Higher voltage rating (640/1100 V) accommodates larger mining equipment power demands
  • Dedicated unscreened earth core provides optimized low-impedance fault current path
  • Separate pilot core allows independent monitoring and control functions
  • Phase-only screening balances EMI protection with simplified termination
  • Extended temperature range (-40°C) suits deep underground applications
  • Higher short circuit ratings (up to 7,300 A) for robust protection coordination

VDE 0250-812 Strengths:

  • Global recognition as ultimate standard for tough rubber sheathed cables
  • Broader application flexibility across industrial sectors
  • Established European certification network
  • Extensive product variants (NSSHÖU, NSHTÖU, etc.)
  • Lower voltage rating may suit some applications with cost benefits

Selection Decision Matrix

Application RequirementRecommended ChoiceTechnical Justification
Underground coal mining (methane risk)BS 6708 Type 14Specific explosive atmosphere design
High-power equipment (>100A continuous)BS 6708 Type 14Higher voltage and current ratings
Simplified earth continuity managementBS 6708 Type 14Dedicated unscreened earth core
General industrial heavy-duty applicationsVDE 0250-812Broader equipment compatibility
Lower voltage systems (<750V)VDE 0250-812Cost optimization
Deep mines with extreme temperaturesBS 6708 Type 14Superior low-temperature flexibility
Comparison Reference: DIN VDE 0250-812 Standard – Cables for power installation. VDE Publishing House

Safety Thresholds and Operational Precautions

Critical Temperature Limits

⚠️ Maximum Temperature Thresholds:

  • Maximum Conductor Temperature (Continuous): 90°C
  • Short Circuit Temperature (1 second max): 250°C
  • Ambient Temperature Range: -40°C to +85°C
  • Installation Temperature Minimum: -20°C (to prevent sheath cracking)

Warning: Exceeding temperature limits causes irreversible damage to EPR insulation and chloroprene sheath, potentially leading to electrical failure and fire hazards in explosive atmospheres.

Mechanical Safety Parameters

Safety ParameterThreshold ValueConsequences of Exceeding
Minimum Bending RadiusApprox. 9×D (varies by size)Internal conductor stress, insulation cracking
Maximum Pulling Tension (95mm²)1,446 kgfConductor elongation, strand breakage
Permanent Tensile Force15 N/mm²Permanent cable deformation
Outer Sheath IntegrityNo breachesMoisture ingress, chemical attack on insulation

Explosive Atmosphere Safety Considerations

According to Amplex Mining Cable Guide, explosion-proof characteristics are essential in underground coal mining where methane gas or coal dust can create explosive atmospheres. Type 14 cables incorporate specific safety features:

Intrinsic Safety Features:

  • Heavy-duty chloroprene sheath: Flame retardant, self-extinguishing (EN/IEC 60332-1-2 compliant)
  • EPR insulation: High dielectric strength prevents electrical tracking
  • Composite screening: Minimizes spark generation from electromagnetic interference
  • Tinned copper conductors: Corrosion-resistant connections reduce high-resistance faults
  • Robust earthing: Dedicated earth core ensures rapid fault clearance

Installation Safety Requirements

Pre-Installation Safety Checklist:

  1. Verify cable voltage rating matches system requirements (640/1100 V)
  2. Confirm conductor cross-section adequate for maximum load current
  3. Check ambient temperature within -40°C to +85°C range
  4. Ensure cable routing maintains minimum bending radius throughout
  5. Verify earth continuity path integrity (earth core + screens)
  6. Test insulation resistance (>100 MΩ·km at 20°C)
  7. Conduct voltage withstand test (3 kV AC for 5 minutes)
  8. Verify protective device settings match cable fault ratings
  9. Confirm cable terminations use approved explosion-proof glands
  10. Document all test results for compliance records

Operational Monitoring Requirements

Continuous operational monitoring ensures safe cable performance throughout service life:

Monitoring ParameterFrequencyAcceptance CriteriaAction if Failed
Visual Sheath InspectionWeeklyNo cuts, abrasions, or swellingRepair or replace damaged sections
Insulation ResistanceMonthly>1 MΩ per circuitInvestigate moisture ingress
Earth Core ContinuityMonthly<1 Ω end-to-endCheck terminations and connections
Screen ResistanceQuarterlyWithin 10% of rated valueVerify screen bonding integrity
Conductor TemperatureContinuous (if possible)<90°CReduce load or improve cooling
High Voltage TestAnnuallyPass 3 kV for 5 minutesReplace cable section

Fault Current Protection Coordination

Protective device settings must coordinate with Type 14 cable fault current ratings to ensure rapid fault clearance while preventing nuisance tripping:

Protection Coordination Example (3×95+2×50):

Cable 1-second short circuit rating: 7,300 A

Recommended protective device settings:
– Instantaneous trip: Maximum 5,840 A (80% of cable rating)
– Time-delayed trip: Adjust I²t characteristic to protect cable
– Ground fault: Set to detect faults >10A through earth core
– Earth continuity monitor: Alarm if earth resistance exceeds 1 Ω

Safety Reference: Mining cable installation and safety guidelines – amplexmining.com.au

Common Problems and Troubleshooting Solutions

Mechanical Failure Modes

Problem 1: Outer Sheath Abrasion and Damage

Symptoms: Visible wear patterns, cuts, exposed internal layers, localized swelling.

Root Causes:

  • Dragging over sharp rock surfaces without cable protection
  • Inadequate cable handler/chain configuration
  • Exceeding minimum bending radius during operation
  • Chemical attack from hydraulic fluid spills

Solutions:

  • Install appropriate cable protection chains rated for mining applications
  • Route cables away from identified abrasion hazards
  • Apply removable protective sleeves at high-wear locations
  • Clean oil/chemical contamination promptly
  • Implement regular inspection schedule (weekly visual checks)

Problem 2: Conductor Fatigue and High-Resistance Faults

Symptoms: Intermittent power loss, unexplained voltage drops, localized heating, insulation discoloration.

Root Causes:

  • Repeated flexing below minimum bending radius
  • Excessive tensile forces during equipment operation
  • Torsional stress from improper cable lay-up
  • Work hardening of copper strands

Solutions:

  • Redesign cable routing to maintain minimum bending radius (420-666mm depending on size)
  • Install tension control devices to limit forces below maximum pulling tension
  • Monitor cable flex cycles and replace before fatigue failure
  • Use thermal imaging to identify hot spots indicating high-resistance connections

Electrical Performance Degradation

Problem 3: Declining Insulation Resistance

Symptoms: Megohmmeter readings below acceptable levels, increased leakage current, ground fault alarms.

Root Causes:

  • Moisture ingress through damaged outer sheath
  • Water tree development in EPR insulation
  • Thermal aging from sustained overtemperature operation
  • Chemical contamination penetrating insulation

Solutions:

  • Repair or replace damaged sheath sections immediately
  • Ensure operation below 90°C conductor temperature
  • Monthly insulation resistance testing (>1 MΩ minimum)
  • Keep cable away from standing water and chemical sources
  • Consider replacing cables showing consistent IR decline trends

Problem 4: Earth Continuity Issues

Symptoms: Earth fault protection fails to operate correctly, elevated touch potentials, ground fault indication without clearing.

Root Causes:

  • Broken or high-resistance earth conductor connections
  • Corrosion at earth core terminations
  • Mechanical damage to unscreened earth core
  • Improper screen bonding connections

Solutions:

  • Monthly earth continuity testing (<1 Ω end-to-end)
  • Clean and re-establish earth termination connections
  • Verify screen bonding at both ends of cable
  • Replace cables with damaged earth core sections
  • Ensure terminations use anti-corrosion compounds

Screen-Specific Issues

Problem 5: Phase Core Screen Degradation

Symptoms: Increased electromagnetic interference, fault current protection issues, heating at screen connections.

Root Causes:

  • Mechanical damage to tinned copper/nylon braid
  • High-resistance screen terminations
  • Corrosion at screen bonding points
  • Improper gland installation not maintaining 360° contact

Solutions:

  • Quarterly screen resistance measurement (should match table values ±10%)
  • Use proper cable glands maintaining complete screen contact
  • Apply anti-oxidant compound to screen connections
  • Verify screen parallel resistance calculation matches expected values

Environmental Challenges

Problem 6: Cold Temperature Performance Issues

Symptoms: Cable becomes stiff and brittle, outer sheath cracking, reduced flexibility.

Root Causes:

  • Installation or operation below -20°C for flexible applications
  • Storage in unheated areas during winter
  • Rapid temperature cycling causing material stress

Solutions:

  • Pre-warm cables to above -10°C before installation in cold environments
  • Increase bending radius allowances in cold temperature operations
  • Specify enhanced cold-grade chloroprene for extreme applications
  • Store cables in temperature-controlled environments

Preventive Maintenance Schedule

Maintenance ActivityFrequencyParameters to CheckPass Criteria
Visual InspectionWeeklySheath damage, abrasion, cutsNo visible damage
Insulation Resistance TestMonthlyMegohmmeter at 1000V DC>1 MΩ per circuit
Earth Continuity TestMonthlyLow-resistance ohmmeter<1 Ω end-to-end
Phase Conductor ResistanceQuarterlyDC resistance at 20°CWithin specified values
Screen ResistanceQuarterly3 screens parallel resistanceWithin ±10% of rated
Termination InspectionQuarterlyTemperature rise, corrosion, tightnessNo heating, clean contacts
High Voltage Withstand TestAnnually3 kV AC for 5 minutesNo breakdown
Troubleshooting Reference: Mining cable maintenance and diagnostic procedures – reelingcable.com technology solutions

Contact Anhui Feichun Special Cable Co., Ltd.

Expert Technical Support for BS 6708 Type 14 Trailing Cables

Our specialized engineering team provides comprehensive technical consultation for Type 14 mining cable applications, including custom configurations, installation guidance, fault analysis, and performance optimization for high-power mining equipment.

📧
Technical Inquiries:
[email protected]
📧
Sales Department:
[email protected]
📱
WhatsApp Support:
+86 138 5512 3218

Why Choose Feichun for Type 14 Cables?

  • ISO 9001:2015 Certified Manufacturing
  • Full BS 6708 Compliance Testing
  • IEC 60228 Class 5 Conductor Production
  • Custom Cross-Section Configurations (25-95mm²)
  • Global Export Experience to Mining Operations
  • Complete Technical Documentation Package
  • Factory Test Certificates Provided

Request Technical Data Package

Contact our engineering team for comprehensive technical data sheets including:

  • Detailed dimensional drawings for all Type 14 configurations
  • Factory test certificates (voltage withstand, insulation resistance)
  • Material certification documents (EPR compound, chloroprene sheath)
  • Installation and termination guidelines
  • Short circuit coordination calculations
  • Custom length and configuration quotations

References and Further Reading

  1. British Standards Institution. (1998). BS 6708:1998 – Flexible cables for use at mines and quarries. BSI Group.
  2. International Electrotechnical Commission. (2004). IEC 60228 – Conductors of insulated cables. IEC.
  3. International Electrotechnical Commission. (1988). IEC 60949 – Calculation of thermally permissible short-circuit currents. IEC.
  4. Amplex Mining Solutions. (2025). BS 6708 Type 321 Mining Cable Technical Guide. Retrieved from amplexmining.com.au
  5. Reeling Cable Technology. (2025). Coal Cutter Cables for Underground Mining Applications. Retrieved from reelingcable.com
  6. Tratos Group. (2023). BS 6708 Standard Specifications. Retrieved from tratosgroup.com
  7. VDE Publishing House. (1985). DIN VDE 0250-812 – Rubber insulated flexible cable NSSHÖU. VDE.
  8. Eland Cables. (2024). VDE 0250 Standard Cables – Global Recognition. Retrieved from elandcables.com
  9. MSHA Technical Support. (2023). Short-Circuit Calculations for Mining Power Systems. Retrieved from msha.gov
  10. EPR Cable Technology Consortium. (2017). Ethylene Propylene Rubber Cable Properties. Retrieved from eprcable.ims.uconn.edu