What is BS 6708 Type 11 Trailing Cable?

Three phase cores and one pilot core, all with composite individual screens laid up around an elastomeric cradle and in contact with each other

BS 6708 Type 11 Trailing Cable
BS 6708 Type 11 Trailing Cable
What is BS 6708 Type 11 Trailing Cable? Complete Technical Guide | Feichun Cables
ANHUI FEICHUN SPECIAL CABLE CO., LTD.

What is BS 6708 Type 11 Trailing Cable?

Three phase cores and one pilot core, all with composite individual screens laid up around an elastomeric cradle and in contact with each other

Turkish Translation: Kompozit bireysel ekranlı üç faz ve bir kumanda damarı birbirlerine temas edecek şekilde elastomer fitil etrafında bükülür.

Introduction to BS 6708 Type 11 Trailing Cable

The BS 6708 Type 11 Trailing Cable represents a pinnacle of electrical engineering specifically designed for the demanding conditions of underground coal mining and surface quarrying operations. This specialized cable serves as the electrical lifeline for coalface cutters, shuttle cars, and similar face equipment, where reliability and safety are non-negotiable requirements.

Key Definition: BS 6708 Type 11 is a non-armoured cable featuring individually metallic screened cores with a rated voltage of 640/1100 V, specifically designed for use with coalface cutters and other similar machines in explosive atmospheres.

According to the British Standards Institution (BSI), BS 6708:1998 establishes comprehensive requirements for flexible cables used in mining and quarrying operations. The standard addresses unique challenges including explosive atmospheres containing methane gas, corrosive chemical exposure, extreme temperature variations, and mechanical stresses from heavy mobile equipment.

As documented by Amplex Mining Cable Solutions, these cables have become essential components in modern mining operations, serving applications from continuous miners and roadheaders to shuttle cars and roof bolters.

Source: BSI Knowledge – BS 6708:1998 Flexible cables for use at mines and quarries. BSI Group

Purpose and Primary Applications

Core Operational Functions

BS 6708 Type 11 cables are engineered specifically for power supply to coalcutters and other machines operating in challenging mining environments. The cable designation indicates its capability to deliver continuous electrical power while withstanding the dynamic mechanical stresses inherent to mobile mining equipment.

Primary Voltage Rating
640/1100
Volts (U₀/U)
Test Voltage
3
kV AC
Temperature Range
-40 to +85
°C (Operating)

Application Scenarios

Underground Mining Operations

In deep mines where explosive gases such as methane can accumulate in poorly ventilated areas, Type 11 cables provide reliable power transmission while minimizing ignition risks. The composite screening system helps manage electromagnetic interference and provides safe paths for fault currents, essential in potentially explosive atmospheres.

Surface Mining & Quarrying

Surface operations expose cables to wider temperature variations, direct rainfall, and mechanical abrasion from rocky terrain. The heavy-duty chloroprene outer sheath provides exceptional resistance to these environmental challenges.

Primary Equipment Applications:

  • Excavating machines – Continuous miners, roadheaders
  • Crushing machines – Mobile crushers, screening equipment
  • Shuttle cars – Underground material transport
  • Coalface cutters – Longwall shearers, drum cutters
  • At-face equipment – Roof bolters, ventilation systems

According to research published by Reeling Cable Technology Solutions, trailing cables serve as critical lifelines for mobile mining equipment, delivering electrical power while accommodating continuous movement. The cables must balance electrical performance with mechanical durability, featuring optimized tensile strength, insulation integrity, and minimum bending radius specifications.

Technical Reference: Reeling Cable Technology – Mining cutting machine applications. reelingcable.com

Cable Construction and Material Structure

Layer-by-Layer Construction Analysis

The BS 6708 Type 11 cable employs a sophisticated multi-layer construction where each component serves specific functions contributing to overall performance in demanding mining environments.

LayerMaterial/ComponentTechnical SpecificationFunction
1. ConductorElectrolytic Tinned CopperIEC 60228 Class 5Maximum electrical conductivity with corrosion resistance
2. InsulationEPR (Ethylene Propylene Rubber)High dielectric strengthElectrical isolation with thermal stability
3. SeparatorColored Textile TapeColor-coded identificationCore identification (Red, Yellow, Brown, Blue)
4. ScreenTinned Copper/Nylon BraidComposite braided shieldEMI shielding and fault current management
5. Lay-upElastomeric Cradle ConfigurationAll cores in contactMechanical stability and flexibility
6. BeddingRubber-Based CompoundPCP rubber centerInternal cushioning and protection
7. Outer SheathHeavy-Duty ChloropreneFlame retardant elastomerEnvironmental protection and abrasion resistance

Conductor Technology – IEC 60228 Class 5

The conductor system utilizes electrolytic copper providing maximum electrical conductivity essential for minimizing power losses in high-current applications. According to IEC 60228 international standards, Class 5 conductors are specifically intended for flexible cables and cords, representing the most flexible stranding configuration available for general applications.

Class 5 Stranding Characteristics:

  • Construction: Very fine stranded copper conductors
  • Strand Count (16mm²): 126 wires × 0.40mm diameter
  • Flexibility Rating: Optimized for repeated flexing without conductor fatigue
  • Resistance: Maximum 1.24 Ω/km at 20°C (for 16mm² conductor)

The tinning process applied to copper conductors serves multiple purposes beyond corrosion protection. It facilitates reliable electrical connections, prevents galvanic corrosion at terminations, and extends conductor life in moisture-rich mining environments. As noted in IEC 60228 documentation, tinned wires maintain excellent contact properties even in oxidizing atmospheres.

EPR Insulation Properties

Ethylene Propylene Rubber (EPR) insulation provides superior performance characteristics critical for mining applications. According to research from the EPR Cable Technology Consortium, EPR offers significant advantages including:

Dielectric Strength
High
Superior to standard rubbers
Thermal Range
-55 to +150
°C operational
Water Treeing
Low
Resistance superior to XLPE

EPR insulation exhibits excellent resistance to electrical tracking and treeing—common failure modes in cables exposed to contaminated mining environments. The material’s inherent flexibility ensures that the insulation system accommodates mechanical stresses from cable movement without cracking or developing weak points.

Composite Screening System

The tinned copper and nylon braided screen over phase and pilot cores provides comprehensive electromagnetic interference (EMI) shielding crucial in mining environments where multiple electrical systems operate simultaneously. This composite screening serves dual functions:

  • Electromagnetic Compatibility: Reduces interference between power and control circuits
  • Safety Enhancement: Provides multiple paths for fault currents, enabling protective device operation
  • Mechanical Protection: Braided construction maintains flexibility while protecting inner components

Heavy-Duty Chloroprene Outer Sheath

The chloroprene (neoprene) outer sheath represents the critical environmental barrier protecting the cable from harsh mining conditions. According to Eland Cables technical documentation, chloroprene offers optimal combination of mechanical toughness and chemical resistance for mining applications.

PropertyPerformance RatingMining Environment Benefit
Abrasion ResistanceExcellentWithstands dragging over rock surfaces
Oil ResistanceSuperiorResists hydraulic fluids and lubricants
Flame RetardanceSelf-extinguishingCritical for underground fire safety
Ozone ResistanceExcellentPrevents surface cracking
Weather ResistanceOutstandingUV and moisture protection
Material Science Reference: Tratos Cable Academy – Ethylene Propylene Rubber cables. tratosgroup.com

Technical Specifications and Electrical Parameters

Complete Technical Data – 3×16+16 mm² Configuration

The following comprehensive specifications represent the standard 3×16+16 mm² Type 11 trailing cable configuration, providing essential data for engineering calculations and system design.

Parameter CategorySpecificationValueUnit
Phase ConductorNumber and Cross Section3 × 16mm²
Stranding Configuration126/0.40wires/mm
Nominal Conductor Diameter5.50mm
Nominal Insulation Diameter8.85mm
Nominal Screen Diameter11.15mm
Pilot ConductorNumber and Cross Section1 × 16mm²
Stranding Configuration126/0.40wires/mm
Nominal Conductor Diameter5.50mm
Nominal Insulation Diameter8.85mm
Nominal Screen Diameter11.15mm
Cable DetailsMinimum Overall Diameter30.90mm
Maximum Overall Diameter33.00mm
Minimum Bending Radius270mm
Maximum Pulling Tension380kgf
Approximate Cable Weight1,960kg/km

Electrical Performance Parameters

Electrical ParameterValueUnitTest Conditions
Continuous Current Rating85Amperes25°C Ambient
Intermittent Current Rating96Amperes25°C Ambient
Max DC Resistance (Phase)1.240Ω/km20°C
Max DC Resistance (Pilot)1.240Ω/km20°C
Screen Resistance (4 parallel)1.050Ω/km20°C
Nominal Reactance0.109Ω/km50 Hz
Nominal Reactance0.131Ω/km60 Hz
Min Insulation Resistance435MΩ/km20°C
3-Phase Voltage Drop2.62mV/A/mFull Load

Voltage Drop Calculations

The voltage drop parameter of 2.62 mV/A/m is critical for system design, particularly in long trailing cable applications. For a 100-meter cable run at 85A continuous load:

Example Calculation:
Voltage Drop = 2.62 × 85 × 100 / 1000 = 22.27 V
This represents approximately 3.5% of the 640V phase voltage, well within acceptable limits for mining equipment operation.

Specification Source: AEI Cables Technical Data Sheet – Type 11 Trailing Cable to BS 6708:1998. aeicables.co.uk

Compliance with International Standards

Primary Standard: BS 6708:1998

The British Standard BS 6708:1998 “Flexible cables for use at mines and quarries” establishes comprehensive requirements governing the design, construction, testing, and performance of mining cables. According to GlobalSpec Standards Database, the standard is based on National Coal Board Specifications 188, 504, and 505, representing decades of mining industry experience.

BS 6708 Type 11 Classification:

  • Category: Non-armoured cables with individually metallic screened cores
  • Rated Voltage: 640/1100 V
  • Application: Coalface cutters and similar machines
  • Configuration: Three phase cores + one pilot core with composite individual screens

Referenced International Standards

StandardScopeApplication to Type 11
IEC 60228Conductors of insulated cablesClass 5 flexible conductor requirements
IEC 60724Short-circuit temperature limitsThermal performance under fault conditions
BS 7655-1.2Insulating materials – 90°C applicationsEPR insulation compound specifications
BS 7655-2.3Sheathing materialsChloroprene sheath compound requirements
EN/IEC 60332-1-2Flame retardance testingSingle vertical flame test compliance

BCS 188:1978 Reference

The cable design references British Coal Specification 188:1978, which established foundational requirements for trailing cables used with shuttle cars, coal cutters, and similar face equipment. This historical document represented critical safety learnings from mining operations and continues to influence modern cable design through BS 6708.

Testing and Quality Assurance

Type 11 cables undergo rigorous testing protocols including:

Voltage Testing
3 kV
AC Test Voltage
Insulation Resistance
≥435
MΩ/km minimum
Flame Test
Pass
IEC 60332-1-2
Standards Reference: Tratos Group – BS 6708 Standard Overview. tratosgroup.com

Comparison: BS 6708 Type 11 vs. VDE 0250 Part 812

Standards Background

Both British Standard BS 6708 and German Standard DIN VDE 0250 represent mature, internationally recognized frameworks for mining cable specifications. DIN VDE 0250 Part 812 specifically addresses EPR insulated flexible cables designated NSSHÖU, providing an interesting comparison point with BS 6708 Type 11.

According to Eland Cables VDE expertise, Germany is the only country to have issued special design regulations for flexible electrical cables covering cranes and material handling equipment, making DIN VDE 0250 globally recognized as the ultimate standard for tough rubber sheathed flexible cables.

ParameterBS 6708 Type 11VDE 0250 Part 812 (NSSHÖU)Analysis
Rated Voltage640/1100 V450/750 VBS 6708 higher voltage capability
Primary ApplicationCoal mining, underground operationsHeavy-duty industrial, mining tunnelingBoth suited for mining
Conductor StandardIEC 60228 Class 5DIN EN 60228 / VDE 0295Equivalent flexibility class
Insulation MaterialEPR (Ethylene Propylene Rubber)EPR or equivalent elastomerSame base material
ScreeningIndividual composite Cu/Nylon braidOptional screening configurationsBS 6708 mandatory EMI protection
Outer SheathHeavy-duty chloroprene (PCP)Polychloroprene or equivalentComparable protection
Temperature Range-40°C to +85°C-25°C to +90°CBS 6708 better cold performance
Pilot CoreMandatory screened pilot coreEarth core configurationBS 6708 enhanced monitoring
Explosive AtmosphereSpecifically designed for gassy minesGeneral hazardous environmentBS 6708 methane-specific design
Tensile Strength15 N/mm² permanent15 N/mm² (similar specification)Equivalent mechanical rating

Key Differentiators

BS 6708 Type 11 Advantages:

  • Higher voltage rating (640/1100 V) enables powering larger mining equipment
  • Mandatory composite screening on all phase and pilot cores provides superior EMI protection
  • Dedicated screened pilot core enables enhanced monitoring and control functions
  • Specific design for explosive atmospheres with methane gas accumulation
  • Extended cold temperature capability down to -40°C for deep mine applications

VDE 0250 Part 812 Strengths:

  • Global recognition as the ultimate standard for tough rubber sheathed cables
  • Broader application scope including crane and material handling equipment
  • Higher continuous operating temperature (90°C vs. 85°C ambient)
  • Established certification network across European industrial markets
  • Flexibility in screening options for various application requirements

Selection Criteria

The choice between BS 6708 Type 11 and VDE 0250 Part 812 cables depends on specific application requirements:

Application RequirementRecommended StandardRationale
Underground coal mining with methane riskBS 6708 Type 11Specific explosive atmosphere design
Surface quarrying with higher voltage needsBS 6708 Type 11640/1100 V rating advantage
General industrial heavy-duty applicationsVDE 0250 Part 812Broader equipment compatibility
Reeling cable applicationsVDE 0250 Part 813Optimized for drum operations
Integrated monitoring requirementsBS 6708 Type 11Screened pilot core for control
Comparison Reference: DIN VDE 0250-812 Standard Specification. VDE Publishing House

Safety Thresholds and Precautions

Critical Safety Parameters

Operating BS 6708 Type 11 cables within specified safety thresholds is essential for preventing equipment damage and ensuring personnel safety in mining environments.

⚠️ Critical Temperature Limits:

  • Maximum Conductor Temperature: 90°C (continuous operation)
  • Short Circuit Temperature: 200°C (maximum 5-second duration)
  • Ambient Temperature Range: -40°C to +85°C
  • Installation Temperature: Never install below -20°C (risk of sheath cracking)

Mechanical Safety Thresholds

Safety ParameterThreshold ValueConsequence of Exceeding
Minimum Bending Radius (Fixed)4 × Cable DiameterInternal conductor stress fractures
Minimum Bending Radius (Flexible)5 × Cable DiameterAccelerated fatigue failure
Maximum Pulling Tension380 kgf (3×16+16 mm²)Conductor elongation or breakage
Permanent Tensile Force15 N/mm²Permanent deformation of cable

Explosive Atmosphere Precautions

According to Amplex Mining technical documentation, operating in potentially explosive atmospheres requires strict adherence to the following precautions:

  1. Regular Inspection: Visual examination for outer sheath damage that could expose conductors
  2. Earth Continuity Verification: Periodic testing of screening and earth path integrity
  3. Proper Termination: Use of approved explosion-proof connectors and glands
  4. Current Monitoring: Ensure operation below continuous current ratings to prevent overheating
  5. Protective Device Coordination: Verify relay settings for rapid fault clearing

Fire Safety Considerations

Fire represents one of the most serious hazards in underground mining. Type 11 cables incorporate specific fire safety features as documented by Reeling Cable technical resources:

Fire Safety Features:

  • Flame Retardance: Compliant with EN/IEC 60332-1-2
  • Self-Extinguishing: Chloroprene sheath stops burning when flame source removed
  • Low Smoke Emission: Reduces visibility hazards during fire events
  • Halogen-Free Options: Available configurations eliminate toxic gas emission

Installation Safety Requirements

Pre-Installation Checklist:

  1. Verify cable voltage rating matches system requirements
  2. Confirm cable cross-section adequate for load current
  3. Check ambient temperature within operating range
  4. Ensure cable routing respects minimum bending radius
  5. Verify earth/ground connections before energization
  6. Test insulation resistance (minimum 435 MΩ/km at 20°C)
  7. Conduct voltage withstand test at 3 kV AC

Operational Monitoring

Continuous monitoring systems should track:

  • Conductor temperature via thermal sensors
  • Earth continuity through pilot core monitoring
  • Insulation resistance degradation trends
  • Mechanical wear patterns on outer sheath
  • Connection point temperature rise
Safety Reference: Mining Cable Safety Standards – MSHA and IEC Requirements. amplexmining.com.au

Common Problems and Troubleshooting Solutions

Mechanical Failure Issues

Problem 1: Outer Sheath Damage and Abrasion

Symptoms: Visible wear, cuts, or exposure of inner components on the chloroprene sheath.

Root Causes:

  • Dragging over sharp rock surfaces without adequate protection
  • Improper cable chain/handler configuration
  • Exceeding recommended bending radius during operation

Solutions:

  • Install appropriate cable protection chains designed for mining applications
  • Route cables away from identified abrasion points
  • Apply removable protective sleeves at high-wear locations
  • Regular inspection schedule with immediate repair of minor damage

Problem 2: Conductor Fatigue and Breakage

Symptoms: Intermittent power loss, increased resistance readings, localized heating.

Root Causes:

  • Repeated flexing below minimum bending radius specifications
  • Excessive tensile forces during equipment operation
  • Incorrect installation with sharp bending points

Solutions:

  • Redesign cable routing to maintain 5×D minimum bend radius for flexible operations
  • Install tension control devices to prevent exceeding 15 N/mm² permanent load
  • Replace cable chain systems causing stress concentration points
  • Monitor cable flex cycles and replace before fatigue failure

Electrical Performance Degradation

Problem 3: Insulation Resistance Decline

Symptoms: Measured insulation resistance below 435 MΩ/km, increased leakage current.

Root Causes:

  • Moisture ingress through damaged outer sheath
  • Chemical attack on EPR insulation from hydraulic fluids
  • Thermal aging from sustained overtemperature operation
  • Contamination at termination points

Solutions:

  • Immediate repair or replacement of damaged sheath sections
  • Install cable away from known chemical exposure sources
  • Monitor conductor temperature to ensure operation below 90°C
  • Re-terminate connections using approved methods and materials
  • Megohmmeter testing schedule (minimum monthly in harsh environments)

Problem 4: Screening Continuity Loss

Symptoms: Electromagnetic interference issues, earth fault protection malfunction.

Root Causes:

  • Mechanical damage to tinned copper/nylon braid
  • Corrosion at screen termination points
  • Improper gland installation

Solutions:

  • Verify screen resistance (should be approximately 1.05 Ω/km for 4 screens parallel)
  • Clean and re-establish termination connections
  • Use correct cable glands maintaining 360° screen contact
  • Replace cable sections with severe braid damage

Environmental Challenges

Problem 5: Low Temperature Flexibility Loss

Symptoms: Cable becomes stiff and difficult to handle, potential cracking.

Root Causes:

  • Operation below -20°C without proper material grade
  • Storage in cold conditions before installation

Solutions:

  • Specify cold-grade chloroprene sheath for operations below -20°C
  • Pre-warm cables to above -10°C before installation in cold environments
  • Increase bending radius allowances in cold temperature operations

Problem 6: Oil and Chemical Degradation

Symptoms: Swelling or softening of outer sheath, material degradation.

Preventive Measures:

  • Route cables away from hydraulic equipment prone to leaks
  • Clean oil contamination promptly with appropriate solvents
  • Install drip trays or shields where oil exposure is unavoidable
  • Specify enhanced oil-resistant compounds for severe exposure environments

Maintenance Best Practices

Maintenance ActivityFrequencyParameters to Check
Visual InspectionWeeklySheath damage, abrasion, cuts, exposure
Insulation Resistance TestMonthly≥435 MΩ/km at 20°C
Conductor ContinuityMonthly≤1.24 Ω/km per phase at 20°C
Screen ResistanceQuarterly≤1.05 Ω/km (4 screens parallel)
Termination InspectionQuarterlyTemperature rise, corrosion, tightness
High Voltage Withstand TestAnnually3 kV AC for 5 minutes
Troubleshooting Reference: Mining Cable Maintenance Guidelines – Operational Best Practices. amplexmining.com.au

Contact Anhui Feichun Special Cable Co., Ltd.

Expert Technical Support for BS 6708 Type 11 Trailing Cables

Our engineering team provides comprehensive technical consultation for mining cable applications, including custom configurations, installation guidance, and performance optimization.

📧
Technical Inquiries:
[email protected]
📧
Sales Department:
[email protected]
📱
WhatsApp Support:
+86 138 5512 3218

Why Choose Feichun Special Cable?

  • ISO 9001:2015 Certified Manufacturing
  • IEC 60228 Compliant Conductor Production
  • Custom Cable Configurations Available
  • Global Export Experience to Mining Operations
  • Technical Documentation and Testing Certificates

Request Technical Data Sheet

Contact our team for comprehensive technical data sheets, test certificates, and engineering specifications for BS 6708 Type 11 trailing cables in your required cross-sectional areas and configurations.

References and Further Reading

  1. British Standards Institution. (1998). BS 6708:1998 – Flexible cables for use at mines and quarries. BSI Group.
  2. International Electrotechnical Commission. (2004). IEC 60228 – Conductors of insulated cables. IEC.
  3. AEI Cables Ltd. (2023). Type 11 Trailing Cable Technical Specification. Retrieved from www.aeicables.co.uk
  4. Amplex Mining Solutions. (2025). Understanding BS 6708 Type 11 Mining Cable. Retrieved from amplexmining.com.au
  5. Reeling Cable Technology. (2025). Mining Cable Technology Solutions. Retrieved from reelingcable.com
  6. Tratos Group. (2023). BS 6708 Standard Overview. Retrieved from tratosgroup.com
  7. VDE Publishing House. (1985). DIN VDE 0250-812 – Rubber insulated flexible cable NSSHÖU. VDE.
  8. Eland Cables. (2024). EPR Insulated Cables – Benefits and Applications. Retrieved from elandcables.com
Previous Article

What is Type 7 Mining Cable to BS 6708?

Next Article

What is Type 14 BS 6708 Trailing Cable?

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注