HIGH-VOLTAGE XLPE POWER CABLE S36/60÷69(72.5) kV

Professional Wind Turbine Cable Solutions — XRUHKXS, 2XS(FL)2Y, N2XS(FL)2Y Series conforming to IEC 60840 and DIN VDE 0276-632 standards. Engineered for offshore wind farms, power transmission networks, and renewable energy infrastructure.

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
HIGH-VOLTAGE XLPE POWER CABLES 36/60÷69(72.5) kV | XRUHKXS | 2XS(FL)2Y | N2XS(FL)2Y | Wind Turbine Cable – Anhui Feichun Special Cable Co., Ltd.

HIGH-VOLTAGE XLPE POWER CABLES
36/60÷69(72.5) kV

Professional Wind Turbine Cable Solutions — XRUHKXS, 2XS(FL)2Y, N2XS(FL)2Y Series conforming to IEC 60840 and DIN VDE 0276-632 standards. Engineered for offshore wind farms, power transmission networks, and renewable energy infrastructure.

IEC 60840:2020 DIN VDE 0276-632 36/60(72.5) kV XLPE Insulated Wind Turbine Rated

Technical Overview

High-voltage XLPE (Cross-Linked Polyethylene) insulated power cables rated at 36/60÷69(72.5) kV represent the backbone of modern power transmission infrastructure. These cables are specifically engineered for applications requiring exceptional electrical performance, thermal stability, and mechanical durability under demanding operational conditions.

The cable designations XRUHKXS, 2XS(FL)2Y, and N2XS(FL)2Y indicate specific construction standards and regional compliance requirements. According to the International Electrotechnical Commission, IEC 60840 defines test methods and performance requirements for high-voltage power cable systems with extruded insulation, covering systems designed for rated voltages above 30 kV (Um = 36 kV) up to and including 150 kV (Um = 170 kV).

Voltage Rating

Nominal voltage U₀/U(Um): 36/60(72.5) kV to 40/69(72.5) kV. Maximum system voltage 72.5 kV with conductor operating temperature up to 90°C.

Conductor Range

Cross-sectional area from 120 mm² to 3000 mm² with round stranded (RM/RMC) or Milliken segmented (RMS) copper conductor designs per IEC 60228 Class 2.

Insulation System

Triple-extruded XLPE insulation with semi-conductive conductor and insulation screens. Nominal insulation thickness: 10.0 mm for enhanced electrical stress management.

Applications

Wind turbine installations, offshore/onshore wind farms, substation interconnections, underground power distribution, and renewable energy grid integration.

Cable Type Designations

XRUHKXS

According to IEC 60840

Single-core high-voltage cable with XLPE insulation, copper wire screen with longitudinal water barrier, and PE outer sheath. Designed for fixed installations in power transmission systems.

2XS(FL)2Y

According to IEC 60840

XLPE insulated cable with copper wire screen, longitudinally applied laminated sheath (FL), and HDPE outer covering. The “2” prefix indicates XLPE insulation material.

N2XS(FL)2Y

According to DIN VDE 0276-632

German standard designation for XLPE insulated high-voltage cable. “N” indicates standardized construction, “(FL)” denotes longitudinal water barrier, “2Y” specifies PE outer sheath.

Cable Construction Standards

These high-voltage cables are manufactured in accordance with multiple international standards to ensure global compatibility and performance reliability. As noted by industry sources, compliance with IEC 60840 standards ensures consistent electrical and mechanical performance across high-voltage networks, representing critical infrastructure investments designed for decades of reliable service.

Cable Construction Details

  • 1
    Conductor: Copper, round stranded compacted (RM/RMC) or Milliken segmented (RMS) design per IEC 60228 Class 2. Cross-sections from 120 mm² to 3000 mm² available.
  • 2
    Conductor Screen: Extruded semi-conductive XLPE compound, providing uniform electric field distribution at the conductor surface.
  • 3
    Insulation: Cross-linked polyethylene (XLPE), nominal thickness 10.0 mm. Maximum conductor temperature 90°C continuous, 250°C short-circuit.
  • 4
    Insulation Screen: Extruded semi-conductive XLPE compound bonded to insulation, ensuring controlled electric stress at insulation boundary.
  • 5
    Metallic Screen: Copper wire screen with cross-sections of 35 mm² or 50 mm². Short-circuit rating: 7.4 kA/s (35 mm²) or 10.6 kA/s (50 mm²).
  • 6
    Water Barrier (FL): Longitudinally applied laminated aluminum/PE tape providing radial water blocking capability.
  • 7
    Outer Sheath: High-density polyethylene (HDPE) or PE, providing mechanical protection and environmental resistance.

Technical Note: Conductor Types

  • RM (RMC) — Round Multiwire Conductor (Compacted), Class 2 per IEC 60228
  • RMS (Milliken type) — Round Multiwire Segmented Conductor for reduced skin effect in large cross-sections
  • SPB — Single Point Bonded earthing method
  • CB — Cross Bonded earthing method for long cable routes
  • De — Cable outer diameter for spacing calculations

Physical Specifications

The following table presents comprehensive dimensional and mechanical data for the complete range of conductor sizes. All specifications conform to IEC 60840:2020 requirements.

Table 1: Cable Dimensional Data — 36/60÷69(72.5) kV XLPE Insulated Cables
Cross Section
(mm²)
Conductor
Diameter (mm)
Insulation
Thickness (mm)
Diameter Over
Insulation (mm)
Screen Cross
Section (mm²)
Diameter Over
Screen (mm)
Outer Diameter
De (mm)
Cable Weight
(kg/km)
Max Pulling
Force (kN)
Min Bending
Radius (m)
120RM12.8 + 0.310.034.03537.844.12,6706.01.10
150RM14.25 + 0.310.035.43539.245.62,9807.51.14
185RM15.85 + 0.310.037.03540.847.23,3709.251.18
240RM18.5 + 0.310.039.73543.550.03,99012.01.25
300RM20.3 + 0.410.041.53545.351.84,61015.01.30
400RM23.5 + 0.410.045.13549.356.25,65020.01.40
500RM26.3 + 0.510.047.93552.159.26,78025.01.48
630RM30.0 + 0.510.051.83556.063.38,19031.51.58
800RM34.4 + 0.710.056.23560.467.99,94040.01.70
1000RM38.3 + 0.710.060.53565.173.012,13050.01.83
1200RMS42.0 + 0.810.066.05070.678.914,53060.01.97
1400RMS45.8 + 0.810.069.85074.482.916,62070.02.08
1600RMS49.0 + 1.210.073.05077.686.318,52080.02.16
1800RMS52.1 + 1.010.076.15080.789.820,88090.02.25
2000RMS54.4 + 1.010.078.45083.092.122,460100.02.31
2500RMS60.5 + 1.010.085.55090.5100.227,490100.02.50
3000RMS68.4 + 1.010.093.45098.4108.733,760100.02.72

Electrical Parameters

Electrical characteristics are critical for system design, including conductor resistance, capacitance, inductance, and current-carrying capacity. Data is provided for both buried (in ground) and aerial (in air) installation conditions.

Table 2: Electrical Data — Resistance, Capacitance, and Inductance
Cross Section
(mm²)
Conductor R
DC 20°C (Ω/km)
Conductor R
AC 90°C (Ω/km)
Screen R
DC 20°C (Ω/km)
Screen R
DC 80°C (Ω/km)
Electric Field
Stress (kV/mm)
Short-Circuit
Conductor (kA/s)
Short-Circuit
Screen (kA/s)
Capacitance
(μF/km)
Inductance
(mH/km)
120RM0.15300.19570.5260.6505.8 / 2.3917.47.40.1500.621
150RM0.12400.15890.5260.6505.62 / 2.4421.87.40.1600.606
185RM0.09910.12730.5260.6505.45 / 2.526.87.40.1710.592
240RM0.07540.09750.5260.6505.22 / 2.5934.77.40.1900.572
300RM0.06010.07840.5260.6505.09 / 2.6443.47.40.2030.561
400RM0.04700.06220.5260.6504.89 / 2.7257.87.40.2280.548
500RM0.03660.04970.5260.6504.77 / 2.7872.27.40.2470.536
630RM0.02830.04000.5260.6504.64 / 2.8590.87.40.2730.523
800RM0.02210.03320.5260.6504.52 / 2.91115.37.40.3030.509
1000RM0.01760.02830.3780.4674.43 / 2.97144.010.60.3320.502
1200RMS0.01510.02240.3780.4674.34 / 3.02172.710.60.3690.500
1400RMS0.01290.02000.3780.4674.28 / 3.06201.410.60.3950.492
1600RMS0.01130.01840.3780.4674.24 / 3.08230.110.60.4160.487
1800RMS0.01010.01720.3780.4674.21 / 3.1258.810.60.4370.482
2000RMS0.00900.01610.3780.4674.19 / 3.12287.410.60.4530.479
2500RMS0.00720.01430.3780.4674.13 / 3.16359.110.60.5000.474
3000RMS0.00600.01320.3780.4674.07 / 3.2430.810.60.5530.466
Table 3: Current-Carrying Capacity (Ampacity)
Cross Section
(mm²)
In Ground (A)In Air (A)
Flat Formation
SPB/CB ①
Trefoil Formation
SPB/CB ②
Flat Formation
SPB/CB ①
Trefoil Formation
SPB/CB ②
120RM390370480415
150RM440415545470
185RM495470625540
240RM575545740635
300RM650615850730
400RM745700985845
500RM8507951,145975
630RM9708951,3301,120
800RM1,0901,0001,5351,275
1000RM1,2101,0901,7201,420
1200RMS1,3351,2351,9151,625
1400RMS1,4351,3202,0901,760
1600RMS1,5201,3852,2451,880
1800RMS1,5901,4402,3801,980
2000RMS1,6601,4902,4902,060
2500RMS1,7901,5952,7202,240
3000RMS1,9301,6953,0052,440

Installation Configuration Notes

  • ① Flat formation: cables in flat formation, distance between cables = 2 × De
  • ② Trefoil formation: cables in trefoil formation, distance between cables = De
  • Ampacity values based on: Conductor temperature 90°C, soil temperature 20°C, burial depth 1200mm, soil thermal resistivity 1.0 K·m/W
  • Air installation assumes ambient temperature 30°C with natural convection cooling

Wind Turbine Cable Applications

The 36/60(72.5) kV XLPE cables are extensively deployed in wind energy infrastructure, particularly for connecting wind turbines to collector substations and integrating renewable energy into existing grid systems. The transition from 33kV to 66kV array cables represents a significant advancement in offshore wind farm efficiency.

Industry research indicates that higher voltage cables can increase transmittable power by over 100%, enabling the development of larger arrays with more turbines per array circuit. The 66kV voltage level has become the standard for modern offshore wind farm inter-array cabling, with cables typically ranging from 150mm² to 800mm² conductor sizes.

Offshore Wind Farms

Inter-array cables connecting wind turbines to offshore substations. Dynamic cable sections accommodate floating platform movements. Typical cable lengths: 1.5 km or longer per circuit.

Onshore Wind Installations

Underground collector cables from turbine bases to substation. Direct burial or ducted installation methods. Designed for maintenance-free 30+ year service life.

Substation Connections

High-capacity feeder cables connecting collector substations to grid interconnection points. Supports both single-point bonded and cross-bonded earthing configurations.

Grid Integration

Export cables linking wind farms to shore-based grid infrastructure. Compatible with HVAC transmission systems up to 72.5 kV maximum system voltage.

Key Performance Advantages

XLPE insulated high-voltage cables offer numerous advantages for wind turbine applications compared to alternative technologies:

  • ✓
    Superior Thermal Performance: Maximum continuous conductor temperature of 90°C enables higher current density and reduced cable cross-sections compared to PVC or EPR alternatives.
  • ✓
    Excellent Dielectric Properties: Low dielectric constant (ε ≈ 2.3) and dissipation factor minimize capacitive charging current on long cable routes.
  • ✓
    Mechanical Robustness: Cross-linked molecular structure provides superior tensile strength, elongation, and impact resistance for installation in harsh environments.
  • ✓
    Environmental Resistance: Excellent resistance to moisture, chemicals, UV radiation, and marine environments without oil leakage concerns.
  • ✓
    Long Service Life: Type-tested per IEC 60840 to demonstrate 30+ year operational reliability under cyclic loading conditions.

Standards Compliance

Anhui Feichun Special Cable Co., Ltd. manufactures high-voltage XLPE cables in full compliance with international and regional standards to ensure global market acceptance and installation compatibility.

IEC 60840:2020

International Standard

Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV) — Test methods and requirements.

DIN VDE 0276-632

German National Standard

Power cables with extruded insulation for rated voltages from 36 kV up to 150 kV. Harmonized with HD 632 (CENELEC harmonization document).

IEC 60228

Conductor Standard

Conductors of insulated cables — specifies conductor requirements for Class 2 stranded conductors used in high-voltage power cables.

IEC 60287

Current Rating Standard

Electric cables — Calculation of the current rating. Provides methodology for determining continuous current-carrying capacity under various installation conditions.

Testing Requirements

Per IEC 60840, cables undergo comprehensive type testing, routine testing, and sample testing to verify performance and reliability:

Type Test Sequence (30-Year Life Simulation)

  • Partial discharge test at ambient and elevated temperature
  • Tan δ measurement at various temperatures
  • Heating cycle voltage test (20 cycles at 2U₀)
  • Lightning impulse voltage test (±10 impulses)
  • Examination of completed cable

Contact Anhui Feichun Special Cable Co., Ltd.

安徽飞纯特种电缆有限公司 — Your trusted partner for high-voltage XLPE power cable solutions. Contact our technical team for project consultation, specifications, and quotations.

📱
✉️

Technical Support

[email protected]
👤

Sales — Zihao Yang

[email protected]
👤

Sales — Ziyu Huang

[email protected]

References & Resources

For additional information on high-voltage cable technology, installation practices, and industry standards, the following resources are recommended:

  • 1
    International Electrotechnical Commission: IEC 60840:2020 — Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV)
  • 2
    DIN VDE Standards: DIN VDE 0276-632 — German standard for high-voltage extruded insulation power cables
  • 3
  • 4
    CENELEC: HD 632 — Harmonization document for power cables with extruded insulation for rated voltages from 36 kV to 150 kV
Previous Article

What is Wind Turbine Cable?

Next Article

What is H07ZZ-F WIND 450/750V Wind Turbine Cable?