FLEXIFESTOON® DLO
2000V DLO Single-Core Cable for Deep Mining Power Distribution
Contents
- DLO Technology: Deep Level Operations & Locomotive Overhead Design
- 2000V Ultra-High-Voltage Insulation: Design & Breakdown Protection
- Annealed Tinned Copper Conductors: Thermal Resistance & Solderability
- CPE Rubber Sheath: Chemical/Oil/Moisture Resistance in Mining
- Special EPR Insulation: High-Voltage Stress & Partial Discharge
- UL 44 Type RHH/RHW-2 Compliance: North American Standard
- CSA Type RW-90 & MSHA DLO Type 2000V: Mining Certification
- Fire Rating FT4/FT1/VW-1: Flame Retardancy Across Standards
- Single-Core Portfolio: AWG 8–777 mm² (16 Configurations)
- Complete SKU Catalog & Mining Applications
1. DLO Technology: Deep Level Operations & Locomotive Overhead Design
DLO 2000V stands for a specialized mining cable category. The designation indicates cables designed for Deep Level Operations or Diesel Locomotive Overhead power distribution in underground mining environments:
2. 2000V Ultra-High-Voltage Insulation: Design & Breakdown Protection
2.1 Insulation Thickness & Dielectric Strength
The insulation must withstand 2000V nominal voltage (4 kV peak test voltage). This requires specialized EPR formulation and careful thickness design:
3. Annealed Tinned Copper Conductors: Thermal Resistance & Solderability
3.1 Annealing Process & Material Properties
The conductors are specified as “annealed stranded tinned copper”. This requires explanation:
4. CPE Rubber Sheath: Chemical/Oil/Moisture Resistance in Mining
4.1 CPE vs. Standard Rubber Materials
The outer sheath is specified as “special rubber CPE compound”. CPE offers superior chemical resistance compared to standard EPR/EPDM:
5. Special EPR Insulation: High-Voltage Stress & Partial Discharge
The insulation is “special EPR compound” — distinct from standard industrial EPR. This formulation is optimized for 2000V stress and mining environments:
6. UL 44 Type RHH/RHW-2 Compliance: North American Standard
DLO 2000V is certified as UL 44 Type RHH/RHW-2, 1000V (per UL standard). This indicates North American market compliance with specific performance criteria:
7. CSA Type RW-90 & MSHA DLO Type 2000V: Mining Certification
7.1 Canadian Standard (CSA) & U.S. Mining (MSHA) Approval
The cable is certified for CSA Type RW-90/RW90-TC and MSHA DLO Type 2000V. These certifications are essential for mining operations in Canada and the United States:
8. Fire Rating FT4/FT1/VW-1: Flame Retardancy Across Standards
The cable achieves multiple fire ratings: FT4, FT1, and UL VW-1. Understanding these ratings is critical for mining safety:
9. Single-Core Portfolio: AWG 8–777 mm² (16 Configurations)
FLEXIFESTOON® DLO offers an extensive range of single-core conductor sizes. This comprehensive portfolio spans from light-duty to massive ultra-heavy applications:
10. Complete SKU Catalog & Mining Applications
10.1 Complete Part Number Listing
| Part Number | Conductor (AWG/mm²) | Ø (inches/mm) | Weight (Lbs/Mft–kg/km) | Current @ 30°C (A) |
|---|---|---|---|---|
| 0325017L010A08 | 8 / 8.37 | 0.348 / 8.84 | 105–156 | 80 |
| 0325017L010A06 | 6 / 13.3 | 0.386 / 9.8 | 146–217 | 105 |
| 0325017L010A04 | 4 / 21.2 | 0.438 / 11.1 | 206–307 | 140 |
| 0325017L010A02 | 2 / 33.6 | 0.500 / 12.7 | 293–436 | 190 |
| 0325017L010A01 | 1 / 42.4 | 0.613 / 15.6 | 392–584 | 220 |
| 0325017L010A1C | 1/0 / 53.5 | 0.620 / 15.8 | 462–688 | 260 |
| 0325017L010A2C | 2/0 / 67.4 | 0.680 / 17.3 | 558–830 | 300 |
| 0325017L010A3C | 3/0 / 85.0 | 0.752 / 19.1 | 673–1,003 | 350 |
| 0325017L010A4C | 4/0 / 107.2 | 0.780 / 19.8 | 833–1,240 | 405 |
| 0325017L010A5C | 262 mm² | 0.920 / 23.4 | 1,077–1,603 | 467 |
| 0325017L010A6C | 313 mm² | 0.968 / 24.6 | 1,225–1,823 | 518 |
| 0325017L010A7C | 373 mm² | 1.065 / 27.0 | 1,485–2,210 | 588 |
| 0325017L010A9C | 444 mm² | 1.132 / 28.8 | 1,913–2,847 | 649 |
| 0325017L010ABC | 535 mm² | 1.240 / 31.5 | 2,023–3,010 | 715 |
| 0325017L010ADC | 646 mm² | 1.359 / 34.5 | 2,515–3,742 | 814 |
| 0325017L010AFC | 777 mm² | 1.382 / 35.1 | 3,050–4,538 | 900 |
10.2 Mining Application Scenarios
10.3 Installation & Safety Considerations
DLO 2000V installation requires strict adherence to mining electrical codes:
- Grounding: Single-core cables must have dedicated ground conductors (not implicit). Three-phase + ground + neutral = minimum 5 cables per circuit.
- Voltage drop: Over 5+ km underground runs, calculate voltage drop: V_drop = (I × R × L) / 1000. At 400 A over 5 km with 262 mm² cable: ~20V drop (1% — acceptable).
- Ampacity derating: Underground installation in ducts increases conductor temperature. Apply 0.8× derating factor for duct/tray installation vs. free-air.
- Moisture protection: Sealed terminations required. Wet mine conditions accelerate water-tree growth; CPE sheath + sealed ends critical.
- Inspection protocol: MSHA requires annual visual inspection, 5-year electrical testing (dielectric withstand), 10-year detailed forensic analysis of first 1 m and last 1 m of installed cable.