Что такое H07RN-F / 60245 IEC 66(YCW): heavy-duty rubber-sheath cable для ручных устройств, промышленности, сельского хозяйства, света и звука
H07RN-F / 60245 IEC 66(YCW) / YCW — это heavy-duty rubber-sheath cable стандартной тяжёлой конструкции с CCC and VDE dual certification. Кабель предназначен для hand-held and power supply devices, dry and damp interiors, limited outdoor use, light and sound technology, industrial and agricultural use under medium mechanical stress. По предоставленным данным он имеет fine wire bare copper conductors, rubber type EI4 core insulation, black rubber type EM2 outer sheath, U0/U 450/750 V nominal voltage, 2500 V test voltage, flame-retardant behaviour according to IEC 60332-1-2, oil resistance according to EN 60811-404 and compliance with IEC 60245.4.







![GAALFLEX® VFD 2XSLCHK-J 8 GAALFLEX® VFD 2XSLCHK-J: CPR-Compliant Oil-Resistant Halogen-Free Variable Frequency Drive Inverter Connection Cable for European Building and Industrial Applications with Oil-Exposure Environments, Higher-Temperature Industrial Systems, and Mining Operations (0.6/1 kV Nominal Voltage, 4 kV Test Voltage, CPR EU 305/2011 + EN 50575:2014+A1:2016 Compliance with Dca-S1b,d2,a1 Fire Classification [Enhanced Performance: Low Smoke, Zero Halogen, Minimal Toxicity, Limited Corrosive Gases], Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions Plus New 7-Core Option], 1.5–300 mm² Conductor Range Enabling Complete VFD Specification Across Industrial Applications, Flexible Class 5 Red Copper per IEC 60228, Special XLPE [Cross-Linked Polyethylene] Halogen-Free Insulation with Oil Resistance per IEC 60811-404, Low Corrosive Gas Emission per IEC 60754-2, Low Smoke Density per IEC 61034-1-2, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding, Low Mutual Capacitance [70–410 nF/km] Minimizing Cross-Talk, Low Coupling Resistance [Max 250 Ω/km] Supporting Low-Impedance Control, Black Halogen-Free PVC Outer Sheath with UV Resistance for Outdoor Industrial Deployment, Temperature Range −40 to +90°C [Fixed Laying] or −15 to +90°C [Flexible Application] with +90°C Conductor and +250°C Short-Circuit Capability Enabling High-Temperature Industrial Facilities, Mining Application Suitability per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 / DIN VDE 0875 / EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1 / EN 50265-2-1 / IEC 60332-1-2 / DIN VDE 0482 part 266-4-2 / EN 50266-4-2 / IEC 60332-3-24, Insulation Resistance 200+ MΩ·km, Radiation Resistance to 80×10⁶ cJ/kg, Oil-Resistant Construction Eliminating Cable Degradation in Petrochemical/Automotive/Food Processing Environments, Halogen-Free Zero-Halogen Construction Eliminating Toxic Chlorine/Fluorine Emissions During Fire, RoHS and CE Approved, and Complete European and International Compliance Enabling Building Code Acceptance and Professional VFD System Integration in High-Temperature Oil-Exposure Environments)](https://feichuncables.com/blog/wp-content/uploads/image-1387.avif)
![GAALFLEX® TRAY 600 CY Lean 9 GAALFLEX® TRAY 600 CY Lean: UV and Oil-Resistant Shielded Flexible Tray Machine-Tool Cable with Lean-Optimized Diameter for North American Industrial Cable-Tray Installations and EMI-Sensitive Machinery Environments (UL 600V / WTTC 1000V Nominal Voltage, 2 kV Test Voltage, Overall Tinned Copper Braid Screen with Aluminum Tape Wrap Providing 75+ dB EMI Suppression with Lean-Optimized Diameter Preventing Cable-Size Inflation, Comprehensive 3–25 Multi-Core Portfolio with 1–35 mm² Continuous Cross-Section Range Enabling Complete Machinery Cable Specification from Control Through Feeder Distribution with EMI Protection, Flexible 20×D Bending Radius Optimized for Cable-Tray Routing While Maintaining Shield Integrity, Lean-Diameter Design Enabling Tight Installation Spaces Without EMI Performance Compromise, UV-Resistant Special PVC Compound Enabling Outdoor and Equipment Mounting Areas Without Degradation, Oil-Resistant Black PVC Sheath Protecting Against Industrial Machinery Fluids, Radiation Hardening [8×10⁷ cJ/kg] Supporting 40-Year Industrial Infrastructure Design Life, AWM Style 2587 and TC-ER Type Certification Enabling Cable-Tray and Exposed-Run Applications, Numbered EN 50334 Core Identification Providing Permanent Electrical Conductor Coding, Class 5 Flexible Red Copper per IEC 60228, PVC/Nylon Compound Insulation, Aluminum Tape + Tinned Copper Braid Screen + Tinned Copper Drain Wire, FT4 / FT1 / FT2 Flame-Retardant Certification, Temperature Range −40 to +90°C Supporting Extreme Industrial Environments, Complete North American Industrial Compliance Enabling Machinery OEM Acceptance with Integrated EMI Suppression, RoHS and CE Certification, Engineered for Industrial Cable-Tray Installations with EMI Protection, Machine-Tool Environments, Outdoor Industrial Applications, Radiation-Hardened Infrastructure, and Applications Where Shielded EMI Suppression, Complete Multi-Core Standardization, Lean-Diameter Optimization, Flexible Tray-Cable Rating, Outdoor Durability, and Professional Industrial Equipment Compliance Are Mission-Critical Requirements)](https://feichuncables.com/blog/wp-content/uploads/image-1376.avif)
![GAALFLEX® TRAY 1002 10 GAALFLEX® TRAY 1002: Comprehensive Multi-Standard Oil-Resistant Flexible Tray Machine-Tool Cable for North American Industrial Cable-Tray Installations, Direct Burial Deployment, and Wind-Turbine Applications (Dual UL 600V [TC-ER/MTW] and 1000V [AWM/WTTC] Nominal Voltage Options, 4 kV Test Voltage, Comprehensive 2–65 Multi-Core Portfolio with 0.5–240 mm² Continuous Cross-Section Range Enabling Complete Machinery Specification from Fine Control Through Extra-Heavy Utility Feeder Distribution, Direct-Burial Capability [Wet-Location Insulation per UL 1277.5.2] Enabling Underground Routing Without Conduit, Oil-Resistant Black PVC Sheath [UL OIL RES I] Protecting Against Industrial Machinery Fluids and Petroleum Exposure, Water-Resistant Insulation Supporting Submerged and Wet Applications, UV and Sunlight-Resistant Compound [EN 50396 / HD 605 A1] Enabling Outdoor Deployment, Flexible 13×D Bending Radius Optimized for Cable-Tray Routing and Equipment Mounting, GAALTHERM® 522 Insulation Compound, Class 5 Flexible Red Copper per IEC 60228, Numbered EN 50334 Core Identification, FT4 / FT1 Flame-Retardant Certification per UL 1685, Crushing Resistance per UL 1277 Sections 18.1–18.6 Enabling Direct Burial in Challenging Soil Conditions, Temperature Range −40 to +90°C [UL-AWM to +105°C] Supporting Extreme Industrial Environments, NFPA 79 2007 and NEC 336.10(7) Industrial Machinery Compliance, Complete North American Multi-Standard Compliance Enabling Machinery OEM Acceptance Across Diverse Applications Including Cable-Tray Installation, Direct Burial Underground Routing, Machine-Tool Equipment, Wind-Turbine Tray Cables, and Flexible Motor Supply Leads, RoHS and CE Certification)](https://feichuncables.com/blog/wp-content/uploads/image-1375.avif)

![GAALFLEX® CONTROL 600 CY Lean 12 GAALFLEX® CONTROL 600 PVC: UL/CSA Certified Multi-Core Control Cable for North American Industrial Applications with Comprehensive 2–50 Core Standardization and Complete 0.5–70 mm² Cross-Section Coverage (UL 1000V / CSA 1000V Nominal Voltage [600V Option Available], 3 kV Test Voltage per DIN VDE 0281 Part 2 + HD 21.2, Compact 4×D Fixed-Laying Bending Radius Enabling Tight Equipment Routing Through Industrial Enclosures and Control Panels, Comprehensive 2–50 Multi-Core Portfolio with 0.5–70 mm² Continuous Cross-Section Range Enabling Single-Product Specification Across All Industrial Control Applications, Flexible Class 5 Red Bare Copper per IEC 60228 and DIN VDE 0295, GAALTHERM® 521 Insulation and Grey (RAL 7001) GAALTHERM® 521 Outer Sheath Engineered for North American Industrial Environments, Oil-Resistant Chemistry per DIN EN 50290-2-22 / VDE 0819-102 TM54 Enabling Safe Deployment in Oil-Exposed Areas and Industrial Machine Environments, UL VW-1 and CSA FT1 Flame-Retardant Certification Providing Professional-Grade Fire Safety, Plus IEC 60332-1-2 and IEC 60332-3-24 Enhanced Flame Testing, Black EN 50334 Numbered Cores (2–5 Cores) or DIN VDE 0293-308 Color-Coded Cores (from 6 Cores) plus Green-Yellow Earth Protection (from 3 Cores) Enabling Standard Wiring Without Reference Documentation, Temperature Range −40 to +90°C Fixed Installation / −5 to +90°C Non-Continuously Flexible Deployment Optimized for Industrial Climate Variations, North American UL AWM Style Certification (21179 for 90°C/1000V or 105°C/1000V, or Style 2587 for 90°C/600V) Enabling Direct Acceptance in North American Equipment and Control Systems, RoHS and CE Certification, Engineered for North American Industrial Plant Electrical Distribution, Equipment Interconnection Systems, Industrial Automation Control Circuits, Heavy Manufacturing Facilities, Chemical Plant Installations, and Applications Where UL/CSA Certification, Comprehensive Multi-Core Standardization, Oil Resistance, and Professional Industrial Reliability Are Operational Requirements)](https://feichuncables.com/blog/wp-content/uploads/image-1368.avif)
![GAALFLEX® CONTROL 600 13 GAALFLEX® CONTROL 600 PVC: UL/CSA Certified Multi-Core Control Cable for North American Industrial Applications with Comprehensive 2–50 Core Standardization and Complete 0.5–70 mm² Cross-Section Coverage (UL 1000V / CSA 1000V Nominal Voltage [600V Option Available], 3 kV Test Voltage per DIN VDE 0281 Part 2 + HD 21.2, Compact 4×D Fixed-Laying Bending Radius Enabling Tight Equipment Routing Through Industrial Enclosures and Control Panels, Comprehensive 2–50 Multi-Core Portfolio with 0.5–70 mm² Continuous Cross-Section Range Enabling Single-Product Specification Across All Industrial Control Applications, Flexible Class 5 Red Bare Copper per IEC 60228 and DIN VDE 0295, GAALTHERM® 521 Insulation and Grey (RAL 7001) GAALTHERM® 521 Outer Sheath Engineered for North American Industrial Environments, Oil-Resistant Chemistry per DIN EN 50290-2-22 / VDE 0819-102 TM54 Enabling Safe Deployment in Oil-Exposed Areas and Industrial Machine Environments, UL VW-1 and CSA FT1 Flame-Retardant Certification Providing Professional-Grade Fire Safety, Plus IEC 60332-1-2 and IEC 60332-3-24 Enhanced Flame Testing, Black EN 50334 Numbered Cores (2–5 Cores) or DIN VDE 0293-308 Color-Coded Cores (from 6 Cores) plus Green-Yellow Earth Protection (from 3 Cores) Enabling Standard Wiring Without Reference Documentation, Temperature Range −40 to +90°C Fixed Installation / −5 to +90°C Non-Continuously Flexible Deployment Optimized for Industrial Climate Variations, North American UL AWM Style Certification (21179 for 90°C/1000V or 105°C/1000V, or Style 2587 for 90°C/600V) Enabling Direct Acceptance in North American Equipment and Control Systems, RoHS and CE Certification, Engineered for North American Industrial Plant Electrical Distribution, Equipment Interconnection Systems, Industrial Automation Control Circuits, Heavy Manufacturing Facilities, Chemical Plant Installations, and Applications Where UL/CSA Certification, Comprehensive Multi-Core Standardization, Oil Resistance, and Professional Industrial Reliability Are Operational Requirements)](https://feichuncables.com/blog/wp-content/uploads/image-1367.avif)