DIN VDE 0250-813 Trailing Cable Types

Comprehensive Technical Comparison Guide for Mining and Heavy Industry Applications

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
DIN VDE 0250 Cable Types: Comprehensive Technical Comparison | Mining Cables | Feichun

Feichun Special Cable

Anhui Feichun Special Cable Co., Ltd.

DIN VDE 0250-813 Trailing Cable Types

Comprehensive Technical Comparison Guide for Mining and Heavy Industry Applications

Technical Reference Document

This comprehensive technical guide provides detailed analysis and comparison of various trailing cable types manufactured according to DIN VDE 0250-813 standard, specifically designed for demanding mining and heavy-duty industrial applications.

Standard DIN VDE 0250-813
Application Sector Mining & Heavy Industry
Manufacturer Feichun Cable
Document Version October 2025

📖 DIN VDE 0250-813 Standard Overview

The DIN VDE 0250-813 standard, issued by the German Institute for Standardization (Deutsches Institut für Normung – VDE), specifies comprehensive technical requirements for trailing cables designed for power installations in demanding industrial environments, particularly mining operations.

💡 Definition: Trailing Cables

Trailing cables are flexible power cables specifically engineered for mobile equipment that experiences continuous movement. These cables must withstand multiple simultaneous stresses including:

  • Continuous flexing during equipment operation
  • Mechanical abrasion from contact with rough surfaces
  • Tensile forces during equipment movement
  • Extreme environmental conditions (temperature, moisture, contaminants)
  • Reeling and unreeling cycles on cable drums

Standard Scope and Technical Parameters

ParameterSpecification RangeTechnical Notes
Rated Voltage (U₀/U)0.6/1 kV to 18/30 kVPrimary range: 3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV
Insulation MaterialEPR (Ethylene Propylene Rubber)Type 3GI3 per DIN VDE 0207-20 or superior grades
Operating Temperature-25°C to +90°CContinuous operation at conductor temperature ≤ 90°C
Installation TemperatureMinimum -5°CLower temperatures require pre-warming procedures
Target ApplicationsMining, quarries, heavy industryMobile equipment with high mechanical stress
Configuration OptionsSingle-core or multi-coreWith integrated earth and control conductors

Key Technical Features

🛡️

Enhanced Mechanical Protection

Multi-layer construction with intermediate polyamide reinforcement braid provides exceptional resistance to mechanical stress, extending service life significantly compared to standard industrial cables.

⚡

Superior Electrical Performance

Individual semiconductive screens on power conductors minimize electromagnetic interference and ensure uniform electric field distribution, critical for medium voltage applications.

🌡️

Thermal Stability

Special EPR insulation compounds exceed Type 3GI3 specifications, providing excellent thermal aging resistance and maintaining electrical properties throughout the cable’s design life.

🔄

Optimized Flexibility

Rope-lay conductor construction with special lay lengths and proprietary compounds ensure maximum flexibility while maintaining structural integrity during continuous flexing cycles.

✅ Quality Assurance

All Feichun Cable products manufactured to DIN VDE 0250-813 undergo rigorous testing including:

  • AC voltage withstand test: 5 minutes at specified voltage levels
  • Insulation resistance measurement: Minimum 100 MΩ·km for new cables
  • Conductor resistance verification: Per IEC 60228 class specifications
  • Dimensional compliance: Complete geometric verification
  • Thermal aging tests: 168 hours at 90°C minimum
  • Flexing endurance: Thousands of bending cycles without failure
  • Abrasion resistance: According to DIN VDE 0282 part 1
  • Flame propagation: IEC 60332-3 category compliance

🔌 Cable Type Classifications

The DIN VDE 0250-813 standard encompasses multiple cable configurations, each optimized for specific operational requirements. Understanding the nomenclature and distinguishing characteristics is essential for proper cable selection.

Nomenclature Decoding System

🔤 Understanding Cable Designations

Example designation: R-(N)TSCGEWOU

  • R: Reduced dimension design (optimized weight/flexibility)
  • T: Standard trailing cable construction
  • F: Fixed installation design
  • W: Water-resistant/submersible variant
  • (N): Nominal voltage indicator (medium voltage cables)
  • T: Trailing cable
  • S: Screened (semiconductive screening layers)
  • C: Concentric earth conductor
  • G: Ground check conductor (fail-safe monitoring)
  • E: EPR insulation
  • W: Weather/water resistant sheath
  • O: Oil resistant compounds
  • U: Special construction features

Primary Cable Family Overview

R-(N)TSCGEWOU
Reduced Dimension
  • 3 power + 3 earth conductors
  • Individual semiconductive screens
  • Polyamide reinforcement braid
  • 15-20% lighter than standard type
  • Optimized for reeling applications

Primary Application: Semi-fixed installations, slow trailing, medium-duty equipment with space/weight constraints

R-(N)TSKGEWOU
Reduced with Metal Screens
  • 3 power + 3 earth conductors
  • Individual metallic screens
  • Enhanced EMI rejection
  • Optimized dimensions
  • Suitable for electronic controls

Primary Application: Trailing and reeling on equipment with sensitive electronic control systems requiring EMI protection

T-(N)TSGEWOU
Standard Construction
  • 3 power + 3 earth conductors
  • Robust standard construction
  • Optimal cost-performance ratio
  • Enhanced mechanical resistance
  • General purpose mining application

Primary Application: General trailing in underground and surface mining operations, most common configuration

F-(N)TSGEWOU
Fixed Installation
  • 3 power + 3 earth conductors
  • Fixed installation design
  • High impact resistance
  • No extreme flexing requirements
  • Enhanced static durability

Primary Application: Fixed or semi-permanent installations in demanding mining environments

W-(N)TSGEWOU
Submersible
  • 3 power + 3 earth conductors
  • Water-resistant sheath
  • High moisture resistance
  • Submersible operation capable
  • Extreme wet environment rated

Primary Application: Dredging operations, wet mining environments, submersible pumps

(N)TMOGEWOU
Single-Core
  • Single power conductor
  • Screen with braided wrap
  • CR outer sheath
  • High flexibility
  • Modular system design

Primary Application: Special connections, festoon systems, modular power distribution

Specialized Variants Matrix

Cable DesignationSpecial FeatureTypical Application
(N)TMOGETMPUExtra-heavy duty TPU (Thermoplastic Polyurethane) outer sheathExtreme abrasion conditions, high-stress mobile equipment
(N)TMCWOUSingle-core with CR (Chloroprene Rubber) sheathHigh chemical and thermal resistance applications
NSSHOUScreened conductors with reinforced pilots, CR outer sheathHigh-stress trailing for dredging operations
NSHTOU-JScreened power conductors with reinforced metallic braidHoisting and heavy material handling equipment
(N)3GHSBYCY3 screened power cores, additional metallic screens, LSZH sheathMedium voltage tunnel and underground excavation applications
FOMFLEX2 gel-filled fiber optic tubes + kevlar rod + CR sheathEMI-immune data transmission for mobile equipment
H07RN-F/8UBPower and control wrapped, dual-layer thermoset sheathMulti-purpose general industrial applications

⚠️ Critical Selection Note

Proper cable type selection is critical for operational safety and efficiency. Key factors requiring careful evaluation:

  • Voltage rating: Ensure cable voltage classification exceeds system voltage
  • Movement type: Continuous trailing vs. reeling vs. semi-fixed installation
  • Environmental factors: Water, chemicals, extreme temperatures
  • Mechanical stress level: Expected abrasion, flexing frequency, and tensile forces
  • Special requirements: EMI immunity, fiber optics, ground monitoring, submersibility

📊 Detailed Technical Comparison

To facilitate informed cable selection, this section provides comprehensive technical comparisons across key performance parameters for the primary DIN VDE 0250-813 cable types.

Comprehensive Comparison Matrix

Cable TypeGeneral ConstructionKey CharacteristicsVoltage RatingSpecific Applications
R-(N)TSCGEWOU3 power + 3 protective earth screened, semiconductive conductive filler, CR sheath with intermediate braid reinforcement • Excellent flexibility
• High impact & abrasion resistance
• Flame retardant
• UV, ozone, oil resistant
3.6/6-18/20kVSemi-fixed/trailing: Suitable for environmental and mechanical stress in mining. Weather-resistant for adverse conditions.
R-(N)TSKGEWOU3 power + 3 protective earth, semiconductive conductive filler, braid directly over assembled cores, CR sheath • Excellent flexibility
• High impact & abrasion resistance
• Flame retardant
• UV, ozone, oil resistant
3.6/6-18/20kVTrailing and reeling: Suitable for mining environmental and mechanical conditions. Internal core damage protection reinforcement.
T-(N)TSGEWOU3 power + 3 protective earth, semiconductive conductive filler, braid directly over assembled cores, CR sheath • Excellent flexibility
• High impact & abrasion resistance
• Flame retardant
• UV, ozone, oil resistant
3.6/6-18/20kVTrailing: Suitable for environmental and mechanical conditions inherent in mining industry. Trailing-appropriate design.
F-(N)TSGEWOU3 power + 3 earth, rubber central filler, CR sheath • High impact & abrasion resistance
• Flame retardant
• UV, ozone, oil resistant
3.6/6-18/20kVFixed installation: Special cable for fixed installation in demanding mining environment.
W-(N)TSGEWOU3 power + 3 earth screened or unscreened, special synthetic waterproof sheath under CR outer sheath • High water, tear, impact resistance
• High abrasion resistance
• UV, ozone, oil resistant
3.6/6-18/20kVWater power supply: High-water dredging, saltwater service in demanding mining environment.
(N)TMOGEWOU / (N)TMCWOUFlexible single-core, concentric wrap or braided screen, CR insulation, CR outer jacket • Moisture resistant & flame retardant
• Very good weather & oil resistance
• Easy handling
3.6/6-18/20kVFlexible single-core: With concentric screen or braid.
(N)TMOGETMPU3 power + 3 protective earth, extra-heavy duty TPU sheath • High abrasion & tear resistance
• Oil resistant
Based on DIN VDE 0250-813Portable trailing cable: Dedicated for extreme condition operation with mechanical stress. Suitable for cable reel powered equipment.

Mechanical Properties Comparison

15 N/mm² Minimum

Tensile Strength

Standard types meet minimum 15 N/mm². Polyamide-reinforced or TPU construction variants achieve values exceeding 20 N/mm².

300% Minimum EPR

Elongation at Break

Indicates excellent elasticity and capability to absorb mechanical impacts without premature insulation failure.

30 N/mm Minimum

Tear Resistance

Cables with TPU or reinforced CR sheath offer superior protection against cuts and punctures in harsh environments.

7.5D Reeling Operation

Minimum Bending Radius

“R” (reduced) types may offer tighter radii due to optimized flexibility design while maintaining structural integrity.

Environmental and Chemical Resistance Comparison

Environmental FactorR/T-NTSCGEWOUW-NTSGEWOU(N)TMOGETMPUTechnical Notes
Water ResistanceGoodExcellent (submersible rated)Very GoodW-type specifically designed for immersion applications
Oil ResistanceExcellentExcellentExceptionalAll types compatible with mineral oils and lubricants
UV ResistanceVery GoodVery GoodExcellentBlack sheath with UV stabilizers for outdoor applications
Ozone ResistanceExcellentExcellentExcellentInherent to EPR insulation and CR/TPU sheaths
Temperature Range-25°C to +90°C-25°C to +90°C-25°C to +90°CFixed installation: down to -40°C
Flame RetardancyYes (IEC 60332)YesYesAll types comply with flame propagation requirements
Smoke EmissionModerateModerateModerateLSZH variants available (e.g., (N)3GHSBYCY)

🔬 Quality Assurance Testing

All Feichun Cable DIN VDE 0250-813 products undergo rigorous quality verification:

  • AC voltage withstand test: 5 minutes at standard-specified voltage (e.g., 17 kV for 6/10 kV cables)
  • Insulation resistance: Minimum 100 MΩ·km for new cables
  • Conductor resistance: Per IEC 60228 flexibility class requirements
  • Dimensional verification: Complete insulation and sheath thickness inspection
  • Thermal aging: 168 hours minimum at 90°C
  • Flexing endurance: Thousands of cycles without failure
  • Abrasion testing: According to DIN VDE 0282 part 1
  • Flame propagation: IEC 60332-3 category A, B, or C compliance

✅ Conclusion

DIN VDE 0250-813 trailing cables represent premium engineering solutions for demanding mining and heavy industrial applications, offering an optimal combination of mechanical robustness, electrical reliability, operational versatility, and environmental durability.

🎯 Selection Fundamentals

Base selection on comprehensive analysis of:

  • • Electrical requirements
  • • Environmental conditions
  • • Mechanical stress factors
  • • Application-specific needs

⚙️ Installation Excellence

Strictly adhere to specifications for:

  • • Bending radii limitations
  • • Tensile force thresholds
  • • Termination procedures
  • • Grounding system integrity

🔧 Maintenance Protocol

Implement comprehensive programs including:

  • • Periodic inspections
  • • Electrical testing regimen
  • • Predictive monitoring systems
  • • Timely corrective actions

🌟 Value Proposition

Investment in quality yields measurable benefits:

  • • Minimized downtime incidents
  • • Enhanced personnel safety
  • • Reduced operational costs
  • • Positive long-term ROI

🤝 Feichun Cable Commitment

Anhui Feichun Special Cable Co., Ltd. is committed to delivering:

  • World-class products: Manufactured to the most rigorous international standards
  • Comprehensive technical support: From selection through post-sales service
  • Continuous innovation: Development of advanced solutions for emerging challenges
  • Customer-centric service: Rapid, professional response to all technical inquiries

📚 References and Standards

Applicable Standards and Regulations

  • VDE Verlag – DIN VDE 0250-813, DIN VDE 0207-20, DIN VDE 0207-21
  • IEC – IEC 60228, IEC 60332-3, IEC 60502, IEC 60811, IEC 60724
  • CENELEC – HD 620 (European harmonized standard)
  • ISO 9001:2015 – Quality Management Systems
  • ISO 14001:2015 – Environmental Management Systems

Additional Technical Resources

  • Technical catalogs from international cable manufacturers
  • Application guides for mining cable systems
  • Cable reeling system design publications
  • Medium voltage cable installation and maintenance manuals

⚖️ Disclaimer

This document is provided for informational and educational purposes. Technical specifications may vary by cable configuration and standard updates. Always consult:

  • Official manufacturer technical datasheets
  • Current versions of cited standards
  • Local regulations applicable to specific projects
  • Certified professional engineers for installation design

Document Version: October 2025

Previous Article

DIN VDE 0250

Next Article

What Are the Differences Between Various Cable Types in the AS Standard?

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注