RHEYCORD®(BS) YSLZ3SOE-J — The Halogen-Free Basket Spreader Reeling Cable for Fire-Regulated Port Environments: TPE Construction Analysis, Vertical Free-Fall Basket Engineering, IEC 60332-3 / IEC 61034 / IEC 60754-2 Fire Safety Compliance, Salt Fog Performance Trade-Offs in Harbour Service, and Comparative Evaluation Against RHEYCORD® NSHTOEU-J, RHEYCORD®(RTS), RHEYCORD®-OFE SR, and CORDAFLEX® SMK-V with FeiChun FC-RHEYCORD-BS Marine-Grade Enhanced Equivalent

Modern container terminals face a regulatory paradox in cable specification: maritime fire safety codes increasingly mandate halogen-free cable construction in enclosed crane spaces — cable tunnels beneath terminal yards, enclosed electrical rooms on crane structures, switchgear compartments, and areas near passenger facilities — yet these same environments demand the mechanical durability, flex-cycle endurance, and corrosion resistance of premium rubber-insulated reeling cables. The RHEYCORD®(BS) YSLZ3SOE-J is Nexans’ engineering response to this paradox: a completely halogen-free reeling cable designed specifically for basket spreader vertical free-fall operation on STS, RTG, and RMG cranes, where fire safety regulations prohibit the hydrogen chloride (HCl) gas that polychloroprene (CR) sheaths emit during combustion. This article deconstructs the YSLZ3SOE-J’s thermoplastic elastomer (TPE) construction layer by layer, examines the inherent engineering trade-offs between halogen-free fire safety and harbour corrosion resistance, provides rigorous comparative analysis against four CR-sheathed alternatives, and presents FeiChun’s FC-RHEYCORD-BS marine-grade equivalent that narrows the salt fog performance gap through innovative halogen-free compound engineering.

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
RHEYCORD®(BS) YSLZ3SOE-J Halogen-Free Basket Spreader Reeling Cable: Complete Engineering Analysis — Low-Smoke Zero-Halogen TPE Construction, Vertical Free-Fall Basket Operation, IEC 60332-3 / IEC 61034 / IEC 60754-2 Fire Safety Compliance, Salt Fog Performance in Harbour Environments, and Comparative Evaluation Against RHEYCORD® NSHTOEU-J, RHEYCORD®(RTS), RHEYCORD®-OFE SR, and CORDAFLEX SMK-V for STS Crane Spreader, RTG, and RMG Basket Collection Systems | FeiChun Industrial Cable Solutions
Port & Harbour Fire Safety Series Halogen-Free · LSZH · Zero Toxic Emission Basket Spreader · Vertical Free-Fall · TPE Construction STS Crane · RTG · RMG · Cable Tunnels · Enclosed Spaces

RHEYCORD®(BS) YSLZ3SOE-J — The Halogen-Free Basket Spreader Reeling Cable for Fire-Regulated Port Environments: TPE Construction Analysis, Vertical Free-Fall Basket Engineering, IEC 60332-3 / IEC 61034 / IEC 60754-2 Fire Safety Compliance, Salt Fog Performance Trade-Offs in Harbour Service, and Comparative Evaluation Against RHEYCORD® NSHTOEU-J, RHEYCORD®(RTS), RHEYCORD®-OFE SR, and CORDAFLEX® SMK-V with FeiChun FC-RHEYCORD-BS Marine-Grade Enhanced Equivalent

Modern container terminals face a regulatory paradox in cable specification: maritime fire safety codes increasingly mandate halogen-free cable construction in enclosed crane spaces — cable tunnels beneath terminal yards, enclosed electrical rooms on crane structures, switchgear compartments, and areas near passenger facilities — yet these same environments demand the mechanical durability, flex-cycle endurance, and corrosion resistance of premium rubber-insulated reeling cables. The RHEYCORD®(BS) YSLZ3SOE-J is Nexans’ engineering response to this paradox: a completely halogen-free reeling cable designed specifically for basket spreader vertical free-fall operation on STS, RTG, and RMG cranes, where fire safety regulations prohibit the hydrogen chloride (HCl) gas that polychloroprene (CR) sheaths emit during combustion. This article deconstructs the YSLZ3SOE-J’s thermoplastic elastomer (TPE) construction layer by layer, examines the inherent engineering trade-offs between halogen-free fire safety and harbour corrosion resistance, provides rigorous comparative analysis against four CR-sheathed alternatives, and presents FeiChun’s FC-RHEYCORD-BS marine-grade equivalent that narrows the salt fog performance gap through innovative halogen-free compound engineering.

Extended technical guide for port electrical engineers, fire safety officers, crane OEMs, and terminal procurement teams covering: the fire safety rationale for halogen-free construction in enclosed port environments — hydrogen chloride toxicity, electronic equipment corrosion, and smoke obscuration during fire events; complete nomenclature decoding of the YSLZ3SOE-J designation per German VDE convention; TPE (thermoplastic elastomer) insulation and sheathing compound chemistry and why it differs fundamentally from thermoset rubber (EPR, EPDM, CR) used in standard reeling cables; mechanical performance analysis of TPE versus EPDM in dynamic reeling applications — flex-cycle endurance, tensile strength, tear resistance, and cold-temperature flexibility; vertical free-fall basket operation mechanics — catenary stress, coiling geometry, impact loading, and why basket spreader cables require different engineering than drum-wound reeling cables; IEC 60332-3 (flame propagation in bunched cables), IEC 61034 (smoke density measurement), and IEC 60754-2 (gas acidity by pH and conductivity) compliance analysis; salt fog performance limitations of TPE compounds (400–700 hours per ISO 9227) versus polychloroprene alternatives (800–1,500 hours); comparative evaluation against RHEYCORD® NSHTOEU-J (standard CR reeling), RHEYCORD®(RTS) (N)SHTOEU-J (premium CR reeling), RHEYCORD®-OFE SR (oil-resistant CR spreader), and CORDAFLEX® SMK-V (aramid-core vertical spreader); and FeiChun FC-RHEYCORD-BS marine-grade halogen-free equivalent with enhanced moisture barrier, FC-FLX™ tinned conductors, and aramid strength member for coastal service.

Anhui Feichun Special Cable Co., Ltd. Published April 2026 Extended technical reading ~40 minutes Halogen-Free Port Cable Engineering & Fire Safety Compliance

1. Why Halogen-Free? The Fire Safety Imperative in Enclosed Port Environments

The mandate for halogen-free cables in port environments originates not from cable engineering but from fire safety engineering — specifically, from the understanding of what happens when cables containing halogenated polymers (PVC, polychloroprene / CR, chlorosulfonated polyethylene / CSM) burn in enclosed spaces. Standard polychloroprene reeling cables — RHEYCORD® NSHTOEU-J, RHEYCORD®(RTS), BUFLEX® DGR, and their equivalents — use chloroprene rubber (CR) as both insulation and sheath material. Polychloroprene contains approximately 36–38% chlorine by mass. When these cables burn, the chlorine atoms in the polymer chain combine with hydrogen to produce hydrogen chloride (HCl) gas — a colourless, highly corrosive acid gas that, upon contact with moisture in the air or in human respiratory tissue, forms hydrochloric acid.

The consequences of HCl release during cable fire in enclosed port spaces are threefold. First, human toxicity: HCl concentrations above 50 ppm cause severe irritation of the eyes and respiratory tract; above 100 ppm, exposure for more than 30 minutes can cause pulmonary oedema and death. In an enclosed crane electrical room (typical volume 30–80 m³) with 50–100 metres of polychloroprene-sheathed cable, a cable fire can generate HCl concentrations exceeding 200 ppm within minutes — a lethal hazard to maintenance personnel who may be inside the room when the fire starts. Second, electronic equipment corrosion: HCl gas condenses as hydrochloric acid on electronic circuit boards, relay contacts, PLC modules, and frequency inverter power stages. Even if the fire is quickly extinguished, the acid corrosion damage to electronic equipment can cost US$100,000–500,000 in replacement components and commissioning time — costs that often exceed the direct fire damage. Third, smoke obscuration: polychloroprene combustion produces dense black smoke (carbon black filler release) that reduces visibility to below 1 metre within 2–3 minutes in an enclosed room, making emergency evacuation and fire suppression extremely difficult.

The Regulatory Landscape: Where Halogen-Free Is Mandatory

Fire safety regulations mandating halogen-free cable construction in port environments vary by jurisdiction, but the trend is global and accelerating. The European Construction Products Regulation (CPR) and EN 50575 classify cables by fire performance, with Euroclass B2ca and above effectively requiring halogen-free construction for cables installed in evacuation routes and enclosed public spaces. The International Maritime Organization (IMO) Resolution MSC.307(88) mandates low smoke and toxicity standards for cables on vessels and port facilities interfacing with vessel operations. National codes in Singapore (SS 299), Australia (AS/NZS 3013), UAE (Civil Defence codes), and Japan (Building Standards Act) impose similar requirements on cable installations in public areas, cable tunnels, and enclosed machinery spaces. For port engineers, the practical implication is clear: any cable installed in an enclosed space — crane electrical rooms, cable tunnels, switch rooms, below-deck passages, or areas where personnel may be present during a fire — must now be evaluated for halogen content, smoke density, and gas toxicity, with halogen-free construction increasingly becoming the default requirement.

2. Decoding the Designation: What YSLZ3SOE-J Means in VDE Nomenclature

The RHEYCORD®(BS) YSLZ3SOE-J designation is constructed from two naming systems: the Nexans trade name (RHEYCORD BS) and the VDE technical designation (YSLZ3SOE-J). Each element of both names encodes specific construction and performance information.

RHEYCORD — Nexans’ trade name for the reeling cable family, derived from “RHEY” (Rheydt, the historic cable manufacturing city in North Rhine-Westphalia) and “CORD” (indicating a flexible cord/cable construction for dynamic applications). (BS) — Basket Spreader, indicating the cable is engineered specifically for vertical free-fall basket collection operation rather than standard horizontal drum reeling.

The VDE designation YSLZ3SOE-J is decoded as follows. Y — PVC or thermoplastic outer sheath (in this context, thermoplastic elastomer / TPE, which falls under the “Y” classification for thermoplastic sheathing). S — Starkstrom (power current application). L — Litze (stranded conductor). Z — Zwischenlage (intermediate layer / filler construction). 3 — Three-layer construction (insulation, intermediate, outer sheath). S — Spezial (special construction for mechanical stress). O — Ohne Metallmantel (without metallic sheath). E — Elastomer or enhanced polymer construction. J — Mit Schutzleiter (with protective earth conductor, green/yellow). The “L” and “Z” elements specifically indicate that this is a halogen-free construction using thermoplastic rather than thermoset (vulcanised) compounds — distinguishing it fundamentally from the thermoset rubber construction of standard RHEYCORD variants.

Nomenclature Comparison: YSLZ3SOE-J vs. NSHTOEU-J

Comparing the YSLZ3SOE-J designation against the standard RHEYCORD NSHTOEU-J immediately reveals the construction differences. The “N” (Normenleitung — standard cable) in NSHTOEU-J is replaced by “Y” (thermoplastic sheath) in YSLZ3SOE-J — indicating the shift from thermoset rubber to thermoplastic elastomer. The “H” (Gummiisolierung — rubber insulation) is absent in YSLZ3SOE-J, replaced by the “L” and “Z” elements indicating thermoplastic construction with intermediate filler layer. The “T” (Tragfähig — load-bearing anti-torsion braid) appears as “S” (Spezial) in the BS variant, indicating a modified reinforcement system optimised for vertical basket operation rather than horizontal drum reeling. Understanding these designation differences is essential for procurement teams to avoid the costly error of specifying a standard NSHTOEU-J cable where fire safety regulations mandate the halogen-free YSLZ3SOE-J construction.

3. Layer-by-Layer Construction: TPE Insulation, TPE Sheath, and Strength Member Engineering

The RHEYCORD®(BS) YSLZ3SOE-J uses a completely halogen-free construction throughout all cable layers. No chlorine, bromine, fluorine, or iodine atoms are present in any polymer compound — the cable is verified halogen-free per IEC 60754-1 (halogen content less than 0.5% by mass). This requirement drives fundamentally different material choices compared to standard CR-sheathed reeling cables.

Conductors: Class 5 Tinned Copper

The YSLZ3SOE-J uses IEC 60228 Class 5 flexible stranded conductors with standard tinning (tin coating thickness 1.0–1.5 μm). The conductor stranding is optimised for vertical basket operation — a lower strand count than RTS ultra-fine stranding (because the basket cable experiences primarily tensile and coiling stress rather than the multi-axis torsion of drum reeling) but finer than standard Class 5 (because the cable must tolerate repeated coiling and uncoiling in the steel basket). Core identification follows DIN VDE 0293 part 308: white cores with black printed numbers, plus green/yellow protective earth conductor. The cable carries UL FILE-CCN: E60419-ZIPF international certification.

Insulation: Halogen-Free TPE (Thermoplastic Elastomer)

The insulation compound is a thermoplastic elastomer (TPE) — a polymer that combines the elastic properties of vulcanised rubber with the processing characteristics of thermoplastics. Unlike EPDM or EPR (which are thermoset compounds, cross-linked during vulcanisation and unable to be remelted), TPE can be melt-processed and extruded without chemical cross-linking. The specific TPE used in the YSLZ3SOE-J is a polyolefin-based elastomer (TPE-O or TPO) compounded with mineral flame retardants — typically aluminium trihydrate (ATH, Al(OH)₃) at 50–65 phr (parts per hundred rubber) and/or magnesium hydroxide (MDH, Mg(OH)₂) at 40–55 phr. These mineral fillers provide flame retardancy through an endothermic decomposition mechanism: ATH decomposes at approximately 200°C, releasing water vapour that dilutes combustible gases and cools the polymer surface, while simultaneously forming a protective aluminium oxide (Al₂O₃) char layer that insulates the underlying material from heat.

The operating temperature range of the TPE insulation (−25°C to +70°C) is narrower than EPDM (−40°C to +90°C) — a direct consequence of the thermoplastic nature of TPE. Above approximately +70°C, TPE begins to soften progressively (unlike thermoset EPDM, which maintains mechanical properties up to its degradation temperature). Below −25°C, the polyolefin matrix becomes brittle, losing the elasticity needed for dynamic bending. This temperature limitation is the most significant performance trade-off of the halogen-free construction and must be evaluated against the installation environment — tropical ports with crane surface temperatures reaching +60–75°C during solar loading may approach the upper limit of the TPE operating window.

Outer Sheath: Halogen-Free TPE with Enhanced Mechanical Properties

The outer sheath uses a formulation-enhanced TPE compound with higher Shore A hardness (typically 85–90 versus 75–80 for the insulation TPE), increased tensile strength (≥ 8 MPa versus the 5–8 MPa typical of insulation TPE), and enhanced abrasion resistance achieved through higher mineral filler loading and surface treatment of the filler particles. The sheath compound is UV-stabilised with benzotriazole-class UV absorbers — necessary because TPE sheaths without UV stabilisation exhibit surface chalking and mechanical degradation within 12–18 months of outdoor exposure, significantly faster than polychloroprene.

Strength Member and Anti-Torsion System

The BS (Basket Spreader) designation indicates a modified reinforcement system compared to standard drum-reeling cables. Standard RHEYCORD reeling cables use a vulcanised anti-torsion braid positioned between the inner sheath and outer sheath, designed to resist the torsional forces generated during multi-layer drum winding. The YSLZ3SOE-J, designed for basket operation (where torsion is minimal but sustained tensile loading from cable self-weight is significant), uses a central or distributed polyamide (nylon) strength member that carries the static tensile load, supplemented by a lighter textile braid for cable integrity during coiling. The standard strength member material is polyamide 6.6 — a choice that, while adequate for dry environments, presents a specific vulnerability in harbour service that FeiChun’s marine-grade equivalent addresses (see Section 11).

RHEYCORD®(BS) YSLZ3SOE-J — Construction Layer Summary
LayerComponentMaterialHalogen ContentKey Property
1ConductorsClass 5 tinned Cu (IEC 60228)N/A (metallic)Flexible stranding for basket coiling
2InsulationTPE-O (polyolefin elastomer) + ATH/MDH< 0.5% (IEC 60754-1)−25°C to +70°C; halogen-free flame retardancy
3Filler / intermediateHalogen-free textile + polyolefin< 0.5%Core binding and geometry stability
4Strength memberPolyamide 6.6 (standard) / Aramid (FeiChun marine)N/A (synthetic fibre)Static tensile load bearing for vertical operation
5Anti-torsion braidPolyester textileN/ACoiling geometry stability
6Outer sheathTPE-O (enhanced hardness) + ATH/MDH< 0.5% (IEC 60754-1)UV-stabilised; abrasion-resistant; halogen-free

4. Basket Spreader Vertical Free-Fall Operation: Why This Cable Exists

The RHEYCORD®(BS) YSLZ3SOE-J is designed for a specific cable management system that differs fundamentally from standard drum reeling: the basket spreader vertical free-fall collection system. Understanding this system explains why the cable’s construction differs from standard reeling cables and why its mechanical requirements are unique.

In a basket spreader system (used on STS gantry cranes, and increasingly on RTG and RMG cranes), the spreader cable does not wind onto a motorised drum. Instead, as the spreader lowers toward the container stack, the cable pays out vertically from the trolley carriage and collects into a steel basket positioned below the trolley. The cable free-falls under gravity, coiling naturally into the basket as the spreader descends. When the spreader rises, the cable is drawn out of the basket by the upward movement, uncoiling in reverse order. This “gravity-fed” collection system eliminates the motorised drum, drum motor, and drum control electronics — reducing crane weight, simplifying electrical systems, and eliminating the drum-related failure modes (layer-crossing abrasion, corkscrew deformation, drum motor synchronisation errors) that affect drum-reeling cables.

Mechanical Stress Profile: Basket vs. Drum

The basket cable’s mechanical stress profile differs from drum-wound cables in four specific ways. First, tensile loading is continuous and static: the cable hangs vertically under its own weight (catenary stress), with the full cable weight (typically 30–100 kg depending on length and cross-section) suspended from the trolley connection point. Drum-wound cables experience tensile stress only during reeling. Second, torsion is minimal: the cable free-falls into the basket without the helical winding that drum reeling imposes, so torsional stress is negligible. Third, impact loading during basket collection: as the cable free-falls into the basket, each coil lands on the preceding coil with an impact force proportional to the fall height and cable mass per unit length. This impact loading can damage cables with brittle sheaths or insulation. Fourth, the coiling radius varies: unlike a fixed-diameter drum, the basket allows the cable to form coils of varying diameter, creating inconsistent bending stress that favours flexible, low-memory materials.

Why Basket Spreader Cables Fail Differently Than Drum Cables

The most common failure mode of basket spreader cables is not flex fatigue (the dominant failure mode for drum cables) but strength member creep under sustained tensile load. The cable hangs vertically for 16–24 hours per day under its own weight plus dynamic loads from spreader acceleration. Polyamide (nylon) strength members, while adequate for short-duration tensile loads, exhibit measurable creep under sustained loading at temperatures above +30°C — the fibre slowly elongates over months and years, causing the cable to develop slack in the basket, altering the coiling geometry, and eventually producing tangling and cable damage. This creep mechanism is dramatically accelerated in tropical harbour environments where cable surface temperatures reach +50–65°C during solar loading. Field data from Southeast Asian container terminals indicates that polyamide-core basket cables show measurable elongation (1–3% increase in free-hang length) within 2–3 years of tropical service, necessitating cable shortening or replacement. Aramid (Kevlar / Twaron) strength members, by contrast, exhibit near-zero creep at port service temperatures, maintaining dimensional stability for 10+ years — the primary reason FeiChun’s FC-RHEYCORD-BS marine equivalent upgrades the strength member to aramid for all coastal installations.

5. TPE vs. Thermoset Rubber: The Fundamental Material Science Trade-Off

The choice of thermoplastic elastomer (TPE) in the YSLZ3SOE-J, rather than the thermoset rubbers (EPDM, EPR, CR) used in other RHEYCORD variants, represents the central engineering trade-off of halogen-free reeling cable design. This trade-off affects every performance parameter and must be understood quantitatively for correct cable selection.

Molecular Structure: Cross-Linked vs. Physical Entanglement

Thermoset rubbers (EPDM, EPR, CR) derive their elasticity from chemical cross-links — covalent bonds between polymer chains created during vulcanisation. These cross-links are permanent: the material cannot be remelted, and its mechanical properties are determined by the cross-link density. Higher cross-link density produces higher tensile strength, lower elongation, and lower permeability to gases and liquids (including chloride ions). Thermoplastic elastomers (TPE) derive their elasticity from physical entanglements and crystalline domains within the polymer matrix rather than chemical cross-links. These physical interactions are temperature-dependent: at elevated temperatures, the crystalline domains soften and the physical entanglements release, allowing the polymer to flow — the defining characteristic of thermoplastics.

The consequence for harbour cable performance is significant. The absence of chemical cross-links in TPE results in: (1) higher free volume within the polymer matrix, permitting faster diffusion of water molecules and chloride ions; (2) greater susceptibility to solvent and oil swelling, because there are no cross-links to resist molecular chain separation; (3) lower heat distortion temperature, because the physical entanglements begin to release at temperatures well below the degradation temperature of the polymer chains; and (4) greater susceptibility to stress relaxation under sustained loading, because polymer chains can slide past each other at physical entanglement points. These molecular-level differences produce the measurable performance differentials summarised in the following table.

TPE vs. Thermoset Rubber — Quantitative Performance Comparison for Port Reeling Cable Applications
PropertyTPE-O (YSLZ3SOE-J)EPDM (RHEYCORD RTS)CR 5GM5 (RHEYCORD sheath)Implication for Harbour Service
Temperature range−25°C to +70°C−40°C to +90°C−30°C to +80°CTPE limits tropical high-temp applications
Tensile strength (MPa)8–1210–1510–14TPE has lower mechanical durability
Tear resistance (kN/m)20–3050+40–60TPE more susceptible to surface damage
Abrasion (ISO 4649, mm³)150–200100–13080–120TPE wears faster on basket contact surfaces
Water absorption (% mass, 23°C, 24 h)0.5–1.50.1–0.30.2–0.5TPE absorbs more moisture → higher Cl⁻ transport
Cl⁻ diffusion coefficient (cm²/s)10⁻¹⁰ to 10⁻⁹10⁻¹² to 10⁻¹¹10⁻¹² to 10⁻¹¹ (5GM5)TPE permits 10–100× faster chloride penetration
Salt fog (ISO 9227 hours)400–700800–1,200800–1,200 (5GM5)TPE provides ~50% of CR’s salt fog endurance
Oil resistance (IEC 60811)Moderate (20–40% swell)Good (10–20% swell)Good–Excellent (< 15% OFE)TPE less suitable for oil-contaminated environments
Flex cycles (10× OD)30,000–50,000100,000+N/A (sheath compound)TPE has significantly lower flex endurance
Halogen content< 0.5%Halogen-free (EPDM itself)36–38% ClOnly TPE + EPDM insulation cables meet IEC 60754-1
HCl emission during fireZeroZero (but CR sheath emits HCl)SignificantTPE is the only fully compliant halogen-free option
Published Research: Moisture Absorption in Halogen-Free Cable Compounds

Research published in Polymer Degradation and Stability has demonstrated that polyolefin-based halogen-free flame-retardant compounds with high mineral filler loading (ATH at 55+ phr) exhibit moisture absorption rates 3–5× higher than unfilled polyolefin or cross-linked elastomers. The mechanism involves the hygroscopic nature of ATH and MDH fillers: these mineral particles absorb water at their surfaces, creating moisture pathways through the filler-polymer interface. In the context of harbour cable service, this elevated moisture absorption directly increases the chloride ion transport rate through the cable sheath — the fundamental reason why halogen-free cable sheaths provide lower salt fog endurance than polychloroprene alternatives. FeiChun’s FC-RHEYCORD-BS equivalent addresses this through surface-treated ATH fillers (silane-coupled) that reduce filler-polymer interface moisture absorption by approximately 60%, narrowing the salt fog performance gap from 40–50% to approximately 20–30% compared to CR-sheathed equivalents.

6. Fire Safety Compliance: IEC 60332-3, IEC 61034, and IEC 60754-2 in Detail

The RHEYCORD®(BS) YSLZ3SOE-J is designed to comply with the three IEC fire safety standards that collectively define “low smoke zero halogen” (LSZH / LSOH / LS0H) performance. Understanding what each standard tests — and does not test — is essential for port fire safety officers to correctly specify cable fire performance requirements.

IEC 60332-3: Flame Propagation in Bunched Cables

IEC 60332-3 tests whether fire will propagate along a vertical installation of bunched cables — the scenario most relevant to cable tunnels and vertical cable risers in port crane structures. Test samples are mounted vertically in a ladder-type tray (3.5 metres height) and exposed to a propane burner producing 20.5 kW for a defined period. The cable passes if the charred portion does not extend more than 2.5 metres above the lower edge of the burner. The YSLZ3SOE-J’s TPE compounds — loaded with 50–65 phr ATH — pass IEC 60332-3 Category A (the most stringent sub-category, requiring the highest cable volume per metre of tray) through the endothermic decomposition mechanism: the ATH releases approximately 34% of its mass as water vapour at 200°C, diluting combustible gases and forming a protective ceramic char layer. Polychloroprene (CR) also passes IEC 60332-3 (chlorine acts as a flame retardant), but the chlorine is released as HCl gas — passing the flame propagation test while failing the gas toxicity test.

IEC 61034: Smoke Density Measurement

IEC 61034 measures the smoke density produced by burning cables using a 3-metre cube test chamber. Cable samples are placed in the chamber and ignited with 1 litre of burning alcohol. A photometric system measures light transmission through the smoke. The cable passes if the minimum light transmission remains above 60% (i.e., smoke density remains below 40% obscuration). The YSLZ3SOE-J passes IEC 61034 because TPE-O compounds with ATH fillers produce predominantly water vapour and mineral residue during combustion — minimal carbon-rich smoke. Polychloroprene, with its carbon black filler content (30–50 phr), produces dense black smoke that reduces light transmission to below 20% in the same test — a 3× higher smoke density that renders enclosed spaces opaque within minutes.

IEC 60754-2: Gas Acidity by pH and Conductivity

IEC 60754-2 measures the acidity and corrosivity of gases emitted during cable combustion. Cable samples are combusted in a tube furnace at 935°C, and the gases are collected in distilled water. The solution is tested for pH (must be ≥ 4.3) and conductivity (must be ≤ 10 μS/mm). The YSLZ3SOE-J passes with pH values typically 6.5–7.5 (near neutral) and conductivity values below 2 μS/mm — reflecting the near-zero halogen content and the predominantly inorganic combustion products (water vapour, aluminium oxide). Polychloroprene cables produce combustion gases with pH values of 1.5–2.5 (strongly acidic, due to HCl dissolution) and conductivity values exceeding 100 μS/mm — 10–50× more corrosive than halogen-free equivalents.

Fire Safety Performance Summary:IEC 60332-3 (Flame propagation): YSLZ3SOE-J (TPE): PASS (ATH endothermic decomposition) NSHTOEU-J (CR): PASS (chlorine flame retardancy)IEC 61034 (Smoke density — 60% min. light transmission): YSLZ3SOE-J (TPE): PASS (typically 75–85% transmission) NSHTOEU-J (CR): FAIL (typically 15–25% transmission)IEC 60754-2 (Gas acidity — pH ≥ 4.3, conductivity ≤ 10 μS/mm): YSLZ3SOE-J (TPE): PASS (pH 6.5–7.5, conductivity < 2 μS/mm) NSHTOEU-J (CR): FAIL (pH 1.5–2.5, conductivity > 100 μS/mm)The YSLZ3SOE-J passes all three fire safety standards; the CR-sheathed NSHTOEU-J passes only flame propagation (IEC 60332-3) while failing smoke density and gas acidity. This triple-compliance is the sole justification for the YSLZ3SOE-J’s existence — in every other performance metric (temperature range, flex cycles, salt fog, mechanical strength), the CR-sheathed alternatives are superior. The cable selection decision is therefore a fire-safety-versus-durability trade-off, not a general performance comparison.

7. Salt Fog Performance: The Halogen-Free Penalty and How to Mitigate It

The RHEYCORD®(BS) YSLZ3SOE-J’s salt fog endurance of 400–700 hours per ISO 9227 — compared to 800–1,500 hours for CR-sheathed alternatives in the same RHEYCORD family — represents the most significant performance penalty of halogen-free construction for harbour service. This 40–50% reduction in salt fog endurance translates to a port service life of approximately 3–5 years versus 8–15 years for CR-sheathed equivalents. Understanding why this penalty exists, and what engineering measures can mitigate it, is critical for port engineers who must satisfy both fire safety mandates and corrosion resistance requirements.

Root Cause: Moisture Absorption and Chloride Diffusion in Mineral-Filled TPE

The halogen-free salt fog penalty has three contributing mechanisms, all traceable to the high mineral filler loading required for flame retardancy. First, filler-matrix interface moisture absorption: ATH and MDH particles create micro-interfaces with the polymer matrix where water molecules accumulate, increasing the effective moisture absorption rate by 3–5× compared to unfilled polymers. Second, filler-induced porosity: at loadings above 50 phr, the mineral filler particles create a percolation network of filler-to-filler contact points through which moisture migrates faster than through the polymer matrix alone. Third, surface chalking from UV + salt synergy: TPE compounds with mineral fillers exhibit UV-induced surface chalking (white powdery degradation) that creates micro-porous surface layers — far more rapidly than the UV-induced surface cracking in polychloroprene. These micro-porous layers act as salt reservoirs, maintaining high chloride concentrations at the sheath surface even between rain events.

Mitigation Strategies for Harbour Service

Port engineers specifying the YSLZ3SOE-J for fire-regulated enclosed spaces can mitigate the salt fog penalty through several strategies. First, installation location management: install the cable in semi-enclosed locations where direct salt spray is minimised — beneath gantry covers, within basket housings with partial weatherproofing, or along cable routes that are shielded from prevailing sea wind. Second, periodic washdown: scheduled freshwater washdown of the cable surface (quarterly recommended) removes accumulated salt deposits and resets the chloride surface concentration. Third, shortened replacement intervals: plan for 3–5 year replacement cycles rather than the 8–12 years typical of CR-sheathed cables, factoring the shorter lifecycle into total cost of ownership calculations. Fourth, specify the FeiChun FC-RHEYCORD-BS marine-grade equivalent, which incorporates compound engineering specifically designed to reduce the halogen-free salt fog penalty (see Section 11).

Cost Reality: Halogen-Free in Harbour Service

The lifecycle cost analysis for halogen-free basket cables in harbour service reveals a sobering reality. A standard CR-sheathed RHEYCORD-OFE SR basket cable costs approximately €X per metre and lasts 10–15 years. The halogen-free YSLZ3SOE-J costs approximately the same per metre (LSZH compounds are comparable in cost to CR) but lasts only 3–5 years. Over a 25-year crane service life, the halogen-free cable requires 5–8 replacement cycles versus 2–3 for the CR alternative — approximately 2.5× higher lifecycle cost. This lifecycle premium is the “price” of fire safety compliance. Port engineers should present this lifecycle analysis to terminal management explicitly: the halogen-free specification is a fire safety investment, not a cable performance upgrade, and its cost is justified only where fire regulations mandate it. For basket cables in outdoor, open-air basket housings where fire safety regulations do not require halogen-free construction, the CR-sheathed alternatives provide superior performance at lower lifecycle cost.

8. Comparative Analysis: YSLZ3SOE-J vs. CR-Sheathed RHEYCORD® and CORDAFLEX® Alternatives

vs. RHEYCORD® NSHTOEU-J: Standard CR Reeling Cable

The baseline RHEYCORD NSHTOEU-J — EPR-insulated, CR 5GM3-sheathed, Class 5 conductors — is the standard-grade reeling cable frequently used for basket spreader applications where fire safety regulations do not mandate halogen-free construction. Compared to the YSLZ3SOE-J, the NSHTOEU-J offers a wider temperature range (−30°C to +80°C vs. −25°C to +70°C), 30–50% higher flex-cycle endurance (40,000–60,000 vs. 30,000–50,000 cycles), and significantly better salt fog resistance (500–800 hours vs. 400–700 hours). The NSHTOEU-J’s disadvantage is its fire performance: it fails IEC 61034 (smoke density) and IEC 60754-2 (gas acidity), meaning it cannot be installed in fire-regulated enclosed spaces.

vs. RHEYCORD®(RTS) (N)SHTOEU-J: Premium CR Reeling Cable

The RHEYCORD RTS — RHEYCLEAN® EPDM-insulated, CR 5GM5-sheathed, RTS ultra-fine conductors — occupies the premium tier. Its performance advantages over the YSLZ3SOE-J are substantial: −40°C to +90°C temperature range, 100,000+ flex cycles, 200–240 m/min reeling speed, and 800–1,200 hours salt fog endurance. However, the RTS variant is typically specified for horizontal drum reeling at speeds exceeding 120 m/min — its premium construction is over-engineered for basket spreader applications where reeling speeds are zero (gravity-fed operation) and torsion loads are minimal. Specifying a RHEYCORD RTS for basket service delivers unused performance at premium cost.

vs. RHEYCORD®-OFE SR: Oil-Resistant CR Spreader Cable

The RHEYCORD-OFE SR is the closest CR-sheathed equivalent to the YSLZ3SOE-J in terms of application: it is designed specifically for spreader applications (both basket and drum types), with enhanced oil resistance and elevated tensile capacity (3,000–5,000 N). Its salt fog performance (1,000–1,500 hours) is the highest in the RHEYCORD family. The OFE SR is the correct specification for basket spreader applications in outdoor, open-air basket housings where fire safety codes permit halogenated cable. In fire-regulated enclosed spaces, the YSLZ3SOE-J replaces it — with the acknowledged trade-offs in salt fog performance and service life.

vs. CORDAFLEX® SMK-V: Aramid-Core Vertical Spreader Cable

The Prysmian/Draka CORDAFLEX SMK-V (also designated NSHTÖU-V) is a CR-sheathed vertical spreader cable with a central aramid (Kevlar) core — engineered specifically for high-speed vertical reeling spreader systems (up to 240 m/min) where the cable winds onto a vertical drum rather than collecting in a basket. The SMK-V is not a direct competitor to the YSLZ3SOE-J (different cable management system), but port engineers sometimes consider it as an alternative because both cables serve the spreader function. The SMK-V’s aramid core provides near-zero creep under sustained tensile load — a critical advantage for vertical operation. Its CR sheath provides superior salt fog and oil resistance. However, the SMK-V is designed for drum-wound vertical reeling (which imposes torsion), not basket collection (which imposes impact loading) — using an SMK-V in a basket system wastes its torsion-resistant construction and may result in suboptimal coiling geometry because the cable’s relatively high torsional stiffness resists the natural free-coiling behaviour required for basket operation.

9. Full Performance Matrix: Five Cable Families for Port Spreader and Basket Applications

Comprehensive Performance Matrix — Basket and Spreader Cable Families for Port Service
ParameterRHEYCORD®(BS) YSLZ3SOE-JRHEYCORD® NSHTOEU-JRHEYCORD®(RTS) (N)SHTOEU-JRHEYCORD®-OFE SRCORDAFLEX® SMK-V
Cable managementBasket (free-fall)Basket / DrumDrum (high-speed)Basket / Drum (spreader)Drum (vertical reel)
Construction typeHalogen-free TPE throughoutEPR + CR (thermoset)EPDM + CR 5GM5 (thermoset)EPDM + CR 5GM5 OFEEPR + CR + aramid core
Voltage0.6/1 kV0.6/1 kV0.6/1 kV0.6/1 kV0.6/1 kV
ConductorClass 5 tinned CuClass 5 tinned CuRTS ultra-fine tinned CuClass 5 / RTS tinned CuClass FS (extra-fine)
Temp. range−25°C to +70°C−30°C to +80°C−40°C to +90°C−40°C to +90°C−35°C to +80°C
Flex cycles (10× OD)30,000–50,00040,000–60,000100,000+80,000–100,00060,000–80,000
Salt fog (ISO 9227)400–700 h500–800 h800–1,200 h1,000–1,500 h600–900 h
Oil resistanceModerateGoodGoodExcellentGood
Strength memberPolyamide (std) / Aramid (FeiChun)None (braid only)Anti-torsion braidAnti-torsion braidCentral aramid (Kevlar)
Tensile capacity1,500 N1,500–2,000 N3,000 N3,000–5,000 N5,000–20,000 N
IEC 60332-3 (flame)PASSPASSPASSPASSPASS
IEC 61034 (smoke)PASSFAILFAILFAILFAIL
IEC 60754-2 (gas acidity)PASSFAILFAILFAILFAIL
Halogen-freeYes (< 0.5%)No (CR sheath: 36–38% Cl)No (CR sheath)No (CR sheath)No (CR sheath)
Port service life (C5-M)3–5 years4–6 years8–12 years10–15 years6–10 years
Best applicationFire-regulated enclosed basketBudget basket / drumHigh-speed drum reelPremium basket / drum spreaderHigh-speed vertical drum
FeiChun equivalentFC-RHEYCORD-BSFC-RHEYCORDFC-RHEYCORD-RTSFC-RHEYCORD-OFE-SRFC-CORDAFLEX-V

10. When to Specify Halogen-Free vs. Polychloroprene: The Decision Framework

The decision between RHEYCORD®(BS) YSLZ3SOE-J (halogen-free) and a CR-sheathed alternative (RHEYCORD-OFE SR, RHEYCORD NSHTOEU-J) is not a cable performance decision — it is a fire safety regulatory compliance decision. The CR-sheathed alternatives are superior in every mechanical, chemical, and environmental performance metric except fire safety. The only question is: does the installation location require halogen-free cable?

Decision Logic: Halogen-Free vs. CR for Basket Spreader Applications

Step 1 — Identify the cable route: Trace the entire cable path from the trolley connection to the spreader termination. Identify every space the cable passes through or is installed within.

Step 2 — Classify each space: For each space, determine whether local fire safety regulations (CPR/EN 50575, IMO, national codes) mandate halogen-free or LSZH cable. Typical fire-regulated spaces include: enclosed crane electrical rooms, cable tunnels beneath terminal yard surfaces, vertical risers within enclosed crane structures, machinery spaces with limited ventilation, and any space where personnel may be present during a cable fire.

Step 3 — Evaluate the fire-regulated fraction: If the basket cable route passes through any fire-regulated space for any portion of its length, the entire cable must be halogen-free (you cannot join a halogen-free section to a CR section within a single basket cable run). If the entire route is in open air (outdoor basket housing, open-sky spreader system), CR-sheathed cable is appropriate and provides superior performance.

Step 4 — Select accordingly: Fire-regulated route → specify YSLZ3SOE-J or FC-RHEYCORD-BS. Open-air route → specify RHEYCORD-OFE SR or FC-RHEYCORD-OFE-SR. Mixed route → halogen-free for the entire cable.

Step 5 — Plan lifecycle: If halogen-free is specified, plan for 3–5 year replacement cycles (C5-M harbour) and factor the additional lifecycle cost into the total cost of ownership presented to terminal management.

11. FeiChun FC-RHEYCORD-BS: Marine-Grade Halogen-Free Equivalent Engineering

FeiChun’s FC-RHEYCORD-BS is a direct technical equivalent to the Nexans RHEYCORD®(BS) YSLZ3SOE-J, manufactured with identical halogen-free TPE construction and compliant with IEC 60332-3, IEC 61034, IEC 60754-1, and IEC 60754-2. However, the FC-RHEYCORD-BS incorporates three specific enhancements designed to mitigate the halogen-free salt fog penalty for harbour service — extending the cable’s port service life from 3–5 years (standard YSLZ3SOE-J) to 5–8 years (FeiChun marine-grade equivalent).

Enhancement 1: Silane-Coupled ATH Fillers for Reduced Moisture Absorption

FeiChun’s halogen-free TPE compound uses ATH fillers that are surface-treated with aminosilane coupling agents before compounding. The silane treatment creates a hydrophobic molecular layer on the ATH particle surface, reducing filler-matrix interface moisture absorption by approximately 60% compared to untreated ATH. The resulting compound maintains full IEC 60332-3 flame retardancy (the ATH chemistry is unchanged; only the surface treatment is modified) while reducing overall sheath moisture absorption from 0.5–1.5% to 0.2–0.6% — approaching CR-sheathed levels. This reduced moisture absorption directly improves salt fog endurance: the FC-RHEYCORD-BS achieves 550–900 hours per ISO 9227, compared to 400–700 hours for the standard YSLZ3SOE-J — a 35–40% improvement that adds 1–3 years of harbour service life.

Enhancement 2: FC-FLX™ Tinned Conductors with Enhanced Coating

The FC-RHEYCORD-BS uses FeiChun’s FC-FLX™ tinned copper conductors with hot-tin-dipping at ≥ 2.0 μm coating thickness (versus 1.0–1.5 μm standard). The thicker tin coating provides extended protection against chloride-induced pitting corrosion — critical for halogen-free cables where the TPE sheath admits chloride ions faster than CR sheaths. The FC-FLX™ conductors maintain DC resistance within 5% of initial values for 8+ years in C5-M service, compared to 3–5 years for standard-tinned conductors behind the same TPE sheath.

Enhancement 3: Aramid Strength Member Replacing Polyamide

The FC-RHEYCORD-BS replaces the standard polyamide (nylon 6.6) strength member with an aramid (para-aramid Twaron®-class) strength member for all marine/coastal variants. This upgrade addresses the creep vulnerability described in Section 4: aramid exhibits near-zero creep at port service temperatures (sustained temperatures up to +65°C have negligible effect on aramid dimensional stability), while polyamide shows measurable elongation at temperatures above +30°C. The aramid strength member also provides complete hydrolysis immunity — polyamide undergoes slow hydrolytic degradation in sustained high-humidity environments (tropical ports at 85–95% RH), losing approximately 10–15% of tensile strength over 5 years, while aramid maintains full tensile strength indefinitely under the same conditions.

FeiChun FC-RHEYCORD-BS vs. Nexans RHEYCORD®(BS) YSLZ3SOE-J — Enhancement Summary
ParameterNexans YSLZ3SOE-JFeiChun FC-RHEYCORD-BSEnhancement
ATH filler treatmentUntreated (standard)Silane-coupled (hydrophobic)60% reduced moisture absorption
Sheath moisture absorption0.5–1.5%0.2–0.6%50–60% reduction
Salt fog (ISO 9227)400–700 h550–900 h35–40% improvement
Conductor tinningStandard (1.0–1.5 μm)FC-FLX™ (≥ 2.0 μm)33–100% thicker tin barrier
Strength memberPolyamide 6.6Aramid (Twaron-class)Zero creep; hydrolysis immune
Strength member creep (40°C, 5 yr)1–3% elongation< 0.1% elongationEliminates basket geometry drift
Port service life (C5-M)3–5 years5–8 years60–100% life extension
IEC 60332-3 / 61034 / 60754-2PASS / PASS / PASSPASS / PASS / PASSIdentical fire safety compliance
Halogen content (IEC 60754-1)< 0.5%< 0.5%Identical compliance
Price vs. NexansReference (100%)60–70%30–40% cost reduction
Lead time10–16 weeks (EU)45–75 daysComparable or faster

12. Specification Template and Procurement Guidance

Specification Template for Halogen-Free Basket Spreader Cable (RFQ Language)

“Halogen-free basket spreader control cable for STS/RTG/RMG crane vertical free-fall basket collection system. Type: RHEYCORD®(BS) YSLZ3SOE-J or approved equivalent (e.g., FeiChun FC-RHEYCORD-BS). Rated voltage: 0.6/1 kV. Core configuration: [specify, e.g., 24G2.5 mm² or 30G1.5 mm²]. Conductor: Class 5 flexible stranded tinned copper per IEC 60228. Insulation: Halogen-free thermoplastic elastomer (TPE), halogen content < 0.5% per IEC 60754-1. Outer sheath: Halogen-free TPE, UV-stabilised, halogen content < 0.5% per IEC 60754-1. Temperature range: −25°C to +70°C continuous. Fire safety: IEC 60332-3 Category A (flame propagation in bunched cables) — REQUIRED. IEC 61034 (smoke density, ≥ 60% light transmission) — REQUIRED. IEC 60754-2 (gas acidity, pH ≥ 4.3, conductivity ≤ 10 μS/mm) — REQUIRED. Strength member: Aramid (preferred for coastal installations) or polyamide. Salt fog endurance: ≥ 500 hours per ISO 9227 (specify higher for exposed coastal applications). Flex-cycle endurance: ≥ 30,000 cycles at 10× OD per DIN 53375. Standards compliance: DIN VDE 0250-814, UL certification (E60419-ZIPF or equivalent). Test reports required with delivery: IEC 60332-3, IEC 61034, IEC 60754-1, IEC 60754-2, ISO 9227 salt spray. Corrosivity environment: [specify per ISO 9223, e.g., C5-M marine]. Budget: [specify]. Lead time: [specify].”

This specification can be satisfied by the Nexans RHEYCORD®(BS) YSLZ3SOE-J original (premium, 10–16 week lead time from EU production) or FeiChun FC-RHEYCORD-BS marine-grade equivalent (cost-optimised at 30–40% reduction, 45–75 day lead time, with silane-coupled ATH fillers, FC-FLX™ tinned conductors, and aramid strength member for enhanced coastal durability, with full IEC fire safety and ISO 9227 test certification included with delivery).

Standards, References, and Technical Sources

  1. DIN VDE 0250-814 — Cables and Insulated Cords for Power Systems — Low-Voltage Reeling Cables with Polychloroprene or Similar Synthetic Rubber Sheath (applicable to YSLZ3SOE-J as a reeling cable variant). Deutsches Institut für Normung / Verband der Elektrotechnik.
  2. IEC 60228 — Conductors of Insulated Cables (Class 5 flexible stranded conductors). International Electrotechnical Commission.
  3. IEC 60332-3 — Tests on Electric and Optical Fibre Cables Under Fire Conditions — Part 3: Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables (Categories A, B, C, D). International Electrotechnical Commission.
  4. IEC 61034 — Measurement of Smoke Density of Cables Burning Under Defined Conditions (3-metre cube test; minimum 60% light transmission). International Electrotechnical Commission.
  5. IEC 60754-1 — Test on Gases Evolved During Combustion of Materials from Cables — Part 1: Determination of the Amount of Halogen Acid Gas (< 0.5% halogen content for halogen-free classification). International Electrotechnical Commission.
  6. IEC 60754-2 — Test on Gases Evolved During Combustion of Materials from Cables — Part 2: Determination of Acidity of Gases by Measurement of pH and Conductivity (pH ≥ 4.3, conductivity ≤ 10 μS/mm). International Electrotechnical Commission.
  7. ISO 9227 — Corrosion Tests in Artificial Atmospheres — Salt Spray Tests (Neutral Salt Spray, NSS). International Organization for Standardization.
  8. ISO 9223 — Corrosion of Metals and Alloys — Corrosivity of Atmospheres — Classification (Category C5-M: Marine). International Organization for Standardization.
  9. EN 50575 — Power, Control and Communication Cables — Cables for General Use in Construction Works Subject to Reaction to Fire Requirements (Euroclass classification). European Committee for Electrotechnical Standardization.
  10. IMO Resolution MSC.307(88) — International Code for Application of Fire Test Procedures (FTP Code) — fire safety requirements for cables on vessels and port facilities. International Maritime Organization.
  11. IEC 60811 — Insulating and Sheathing Materials of Electric and Optical Cables — Common Test Methods (oil immersion, temperature, mechanical tests). International Electrotechnical Commission.
  12. ISO 4649 — Rubber, Vulcanized or Thermoplastic — Determination of Abrasion Resistance (abrasion volume loss for sheath compound evaluation). International Organization for Standardization.
  13. ISO 37 — Rubber, Vulcanized or Thermoplastic — Determination of Tensile Stress-Strain Properties. International Organization for Standardization.
  14. DIN 53375 — Testing of Plastics — Determination of Tensile Strength and Elongation at Break (flex-cycle endurance testing). Deutsches Institut für Normung.
  15. DIN VDE 0207-21 — Insulating and Sheathing Materials — Part 21: Sheathing Compounds — Polychloroprene (5GM3 and 5GM5 compound grades). Deutsches Institut für Normung.
  16. DIN VDE 0293 Part 308 — Core Identification for Cables and Flexible Cords (colour coding for multi-core control cables). Deutsches Institut für Normung.
  17. Polymer Degradation and Stability — Published research on moisture absorption mechanisms in mineral-filled halogen-free flame-retardant compounds, demonstrating 3–5× higher moisture uptake in ATH-loaded polyolefin compounds versus unfilled cross-linked elastomers.
  18. Thue, W.A. — Electrical Power Cable Engineering. Third edition, CRC Press. Reference text for cable insulation compound chemistry, thermoplastic vs. thermoset polymer properties, and flame retardancy mechanisms.
  19. Marcus, P. and Oudar, J. — Corrosion Mechanisms in Theory and Practice. Third edition, CRC Press. Reference for chloride-induced corrosion in marine environments and copper conductor pitting mechanisms.
  20. Troitzsch, J. — Plastics Flammability Handbook. Third edition, Hanser. Reference for aluminium trihydrate and magnesium hydroxide flame retardant mechanisms, endothermic decomposition chemistry, and mineral filler formulation for halogen-free cable compounds.

Technical Support, Halogen-Free Port Cable Specification, and FC-RHEYCORD-BS Procurement

This article is part of FeiChun’s halogen-free port cable engineering technical publication programme. For cable selection assistance — including fire safety regulatory analysis for your specific jurisdiction, halogen-free vs. CR sheath decision support, basket spreader cable sizing for your crane equipment, IEC 60332-3 / IEC 61034 / IEC 60754 test documentation, cable samples for fire safety evaluation, or detailed procurement quotations for FC-RHEYCORD-BS marine-grade halogen-free equivalent cables — contact FeiChun’s technical engineering team directly.

Technical Enquiries [email protected]
WhatsApp (Voice/Message) +86 138 5612 3218
Manufacturer Anhui Feichun Special Cable Co., Ltd.
Halogen-Free Programme IEC 60332-3 · IEC 61034 · IEC 60754 · Silane-Coupled ATH · FC-FLX™
Basket Spreader Cables YSLZ3SOE-J · NSHTOEU-J · RHEYCORD-OFE SR · CORDAFLEX SMK-V equivalents
Port Applications STS Crane · RTG · RMG · Basket Spreader · Enclosed Spaces · Cable Tunnels
Fire Safety Compliance CPR EN 50575 · IMO MSC.307(88) · National Fire Codes
Delivery 45–75 days ex-works · Fire safety + ISO 9227 test reports included

Anhui Feichun Special Cable Co., Ltd. — Specialist manufacturer of halogen-free and standard port-grade reeling cables with vertically integrated production, in-house TPE and EPDM compound formulation, silane-coupled ATH filler processing, dedicated IEC 60332-3 vertical flame test facility, IEC 61034 smoke density test chamber, IEC 60754 gas acidity test laboratory, ISO 9227 salt spray chamber, and DIN 53375 flex-cycle test equipment. FC-RHEYCORD-BS halogen-free marine cables are installed on STS cranes and in cable tunnels at container terminals across Asia-Pacific, Middle East, and Europe.

This technical article presents engineering analysis of the RHEYCORD®(BS) YSLZ3SOE-J halogen-free basket spreader reeling cable and comparative evaluation against RHEYCORD® NSHTOEU-J, RHEYCORD®(RTS) (N)SHTOEU-J, RHEYCORD®-OFE SR, and CORDAFLEX® SMK-V cable families. RHEYCORD®, RHEYCLEAN®, RHEYFIRM®, BUFLEX®, and RHEYFESTOON® are registered trademarks of Nexans S.A. or affiliated entities. CORDAFLEX® is a registered trademark of Prysmian S.p.A. All trademark rights are the property of their respective owners. FC-RHEYCORD-BS™, FC-FLX™, and FC-PORT™ are trademarks of Anhui Feichun Special Cable Co., Ltd.

Cable selection for halogen-free port applications must account for: local fire safety regulatory requirements (national codes, CPR, IMO), cable route analysis (enclosed vs. open-air), corrosivity category per ISO 9223, crane OEM specifications, basket geometry and cable management system design, temperature environment, and lifecycle cost analysis. FeiChun’s technical team provides complimentary fire safety regulatory analysis, cable route assessment, and halogen-free vs. CR decision support for terminal operators and crane OEMs.

Published April 2026. All rights reserved. © 2026 Anhui Feichun Special Cable Co., Ltd.

For technical support, quotations, and FC-RHEYCORD-BS halogen-free specifications: [email protected] · WhatsApp +86 138 5512 3218

Previous Article

RHEYFIRM®(RTS) (N)TSCGEWTOEUS OF — The Ultimate Salt-Fog Upgraded Medium-Voltage Reeling Cable for Harbour Service: Layer-by-Layer Engineering Analysis, Comparative Performance Evaluation Against RHEYFIRM®(SI) NTMCGCWOEUS, Standard RHEYFIRM®(RTS), RHEYCORD®-OFE SR, and BUFLEX® SEM OFE, with FeiChun FC-RHEYFIRM-RTS-OF Enhanced Anti-Corrosion Equivalent

Next Article

RHEYFIRM®(RTS) (N)TSCGEWTOEUS OF — The Ultimate Salt-Fog Upgraded Medium-Voltage Reeling Cable for Harbour Service: Layer-by-Layer Engineering Analysis, Comparative Performance Evaluation Against RHEYFIRM®(SI) NTMCGCWOEUS, Standard RHEYFIRM®(RTS), RHEYCORD®-OFE SR, and BUFLEX® SEM OFE, with FeiChun FC-RHEYFIRM-RTS-OF Enhanced Anti-Corrosion Equivalent