What is a YRDMY-J / YRDMCY-J Cable?
C-5 PVC Round Cable Highly Flexible for Energy Guiding Chains

The YRDMY-J and YRDMCY-J cables represent cutting-edge solutions in industrial power transmission and control applications. These highly flexible PVC round cables are specifically engineered for demanding dynamic environments, including energy guiding chains (cable carriers) and festoon systems. Manufactured by Anhui Feichun Special Cable Co., Ltd., these cables combine durability, flexibility, and reliability to meet the rigorous requirements of modern industrial operations.

The designation “YRDMY-J” refers to unscreened power and control cables, while “YRDMCY-J” indicates screened variants with electromagnetic interference (EMI) protection. Both types feature Class 5 flexible copper conductors and are designed to withstand millions of bending cycles in continuous-flex applications.

1. Purpose and Applications

Primary Application: Energy Guiding Chains (Cable Carriers)

Energy guiding chains, also known as cable carriers or drag chains, are mechanical systems that organize and protect cables in dynamic applications. The YRDMY-J and YRDMCY-J cables are specifically optimized for these systems, where cables must undergo constant longitudinal movement and repetitive bending cycles.

Key Application Benefits:

  • Continuous Flex Performance: Designed for travel speeds up to 150 m/min with minimal mechanical stress
  • Long Service Life: Short lay pitch construction enables millions of bending cycles
  • Space-Efficient Design: Compact outer diameter reduces chain size requirements
  • Reliable Power Delivery: Maintains electrical integrity under constant movement

Secondary Application: Festoon Trolleys and Systems

Festoon systems use suspended cable carriers that travel along horizontal tracks to power mobile equipment. These cables excel in festoon applications due to their abrasion-resistant sheath, flexible construction, and ability to handle the unique mechanical stresses of suspended operations.

🏗️

Cranes & Material Handling

Standard indoor cranes, process cranes, overhead cranes, and mobile lifting equipment requiring reliable power supply during operation.

🚜

Agricultural Systems

Irrigation systems, automated farming equipment, and mobile agricultural machinery with dynamic cable requirements.

⚙️

Industrial Automation

Handling equipment, rack feeders, automated storage systems, and robotic applications requiring continuous-flex cables.

🏭

Manufacturing Equipment

Machine tools, production lines, conveyor systems, and any application with moving components requiring power and control.

Applications based on industry standards: DIN VDE 0298-4 (Cable Applications in Power Installations)

2. Key Characteristics and Technical Advantages

Advanced Design Features

🔄 Twist-Free Stranding Technology

Prevention of corkscrews: Conductors are stranded with reverse twist lay, eliminating the tendency to spiral or corkscrew during flexing operations. This critical design feature extends service life and prevents premature failure.

💪 Center Stress Relief Element

Enhanced load capacity: Cables with 5 or more conductors incorporate a central stress relief element that distributes mechanical loads evenly across the cable structure, enabling higher tensile load-bearing capacity (15 N/mm² during operation).

🛡️ Abrasion-Resistant PVC Sheath

Extended durability: Specialized bending-resistant PVC compound provides exceptional resistance to mechanical wear, chemical exposure, and environmental degradation while maintaining flexibility.

📏 Short Lay Pitch Construction

Superior flex life: Short lay pitch (tight stranding) reduces stress on individual conductors during bending, dramatically increasing cycle life compared to standard cables.

🔌 Core-to-Sheath Bonding

Structural integrity: Filler materials create tight bonding between cores and outer sheath, preventing core migration and maintaining cable roundness throughout its service life.

📡 EMI Protection (YRDMCY-J)

Screened variants: Braided copper screen with 85% coverage provides excellent electromagnetic interference protection for sensitive control and signal applications.

Mechanical Performance Characteristics

ParameterSpecificationSignificance
Minimum Bending Radius7.5 × cable diameter (∅)Tight bending capability for compact chain systems
Travel SpeedUp to 150 m/minSuitable for fast-moving industrial equipment
Tensile Load-Bearing Capacity15 N/mm² during operationWithstands dynamic mechanical stress without damage
Conductor Flexibility ClassClass 5 (DIN VDE 0295)Highly flexible stranded copper for continuous-flex applications

3. Material Structure and Construction

Layer-by-Layer Cable Construction

🔧 Conductor Design

Material: Bare electrolytic copper (oxygen-free, high conductivity)

Flexibility Class: Class 5 according to DIN VDE 0295 / IEC 60228

Construction: Fine multi-wire stranded design for maximum flexibility

Purpose: Provides excellent electrical conductivity while maintaining flexibility for millions of bending cycles

🎨 Core Insulation

Material: Polyvinyl chloride (PVC) compound

Color Coding:

  • Up to 5 conductors: Standard colors (brown, black, gray, blue, green/yellow)
  • 6+ conductors: Black cores with white numbering plus green/yellow earth conductor

Standards: Color coding per VDE 0293-308

🌀 Stranding Configuration

Up to 7 conductors: Layer stranding with reverse twist and short lay pitch

8 to 12 conductors: Bundle stranding with reverse twist, short lay, and inner sheath over core bundle for maximum core stability

13+ conductors: Bundle stranding with additional filler materials and reinforced inner sheath

Benefit: Reverse twist eliminates cable rotation (corkscrewing) during flexing

⚡ Electromagnetic Shielding (YRDMCY-J Only)

Shield Type: Braided bare copper wires

Coverage: Approximately 85% optical coverage

Purpose: Protects against electromagnetic interference (EMI) and radio frequency interference (RFI)

Application: Essential for sensitive control systems and data transmission in electrically noisy environments

🛡️ Outer Sheath

Material: Special high-quality bending-resistant PVC compound

Color: Black (opaque) for UV protection

Properties:

  • Exceptional abrasion resistance
  • Oil-resistant formulation
  • UV-resistant for outdoor applications
  • Flame retardant and self-extinguishing
  • CFC-free and LBS-free/silicone-free composition

Cable Designation Code Explanation

YRDMY-J / YRDMCY-J Designation Breakdown:

Y = Insulation material: PVC (Polyvinyl Chloride)

RD = Cable shape: Round (Rund)

M = Cable type designation

C = Shield: Braided copper wires (only in YRDMCY-J)

Y = Sheath material: PVC

J = With green/yellow earth conductor


Example: YRDMY-J 5 G 2.5

= PVC insulated, round, PVC sheathed cable with 5 conductors (including earth), 2.5 mm² cross-section

4. Compliance with International Standards

Primary Standards Compliance

StandardDescriptionCompliance Aspect
DIN VDE 0250Power cables with rated voltagesCable design, construction, and performance requirements
DIN VDE 0295Conductors of insulated cablesClass 5 flexible conductor specifications
DIN VDE 0298-3Application of cables – Tensile loadsTensile load-bearing capacity during operation (15 N/mm²)
DIN VDE 0298-4Application of cables – Current-carrying capacityAmpacity ratings at specified ambient temperatures
IEC 60228Conductors of insulated cablesInternational standard for Class 5 flexible conductors
IEC 60332-1Flame propagation test for single cablesFlame retardant and self-extinguishing properties
DIN VDE 0482-265-2-1Fire behavior of cablesEquivalent to IEC 60332-1 for flame retardancy
UL/CSANorth American safety standardsUL and CSA compliant for North American markets
DESINAGerman industrial standards organizationRecognized by German industrial standards

Flame Retardant Performance

IEC 60332-1 Flame Test Requirements:

The cable is mounted vertically and exposed to a standardized flame for 60 seconds. To pass the test:

  • The cable must self-extinguish after the flame is removed
  • Fire damage must remain at least 50mm below the upper mounting clamp
  • The cable does not propagate flame along its length

This ensures that in the event of fire, the YRDMY-J and YRDMCY-J cables will not contribute to flame spread, providing critical safety in industrial environments.

5. Electrical Parameters and Safety Thresholds

Voltage Ratings

Cable TypeRated Voltage Uo/UMax AC Operating VoltageMax DC Operating Voltage
YRDMY-J (Unscreened)600/1,000 V700/1,200 V900/1,800 V
YRDMCY-J (Screened)300/500 V318/550 V413/825 V
Note: Uo = Voltage between conductor and earth; U = Voltage between conductors

Temperature Ratings and Limits

Operating ConditionTemperature RangeSafety Consideration
Flexing Operation-5°C to +80°CNormal dynamic operation range
Fixed Installation-15°C to +80°CStationary installation range (lower cold limit)
Maximum Conductor Temperature+70°CContinuous operation limit – do not exceed
Short-Circuit Temperature+150°CMaximum allowable temperature during fault conditions (brief duration only)

⚠️ Critical Safety Threshold:

Never exceed +80°C ambient temperature during operation. Operating beyond this threshold can cause:

  • Premature insulation degradation
  • Reduced electrical performance
  • Shortened service life
  • Potential safety hazards

Current-Carrying Capacity (Ampacity)

The ampacity values (IB) listed in the technical specifications are based on:

  • Ambient temperature of 30°C
  • Cables laid on an even, flat support
  • 100% duty cycle (continuous operation)

Ampacity Adjustment Factors:

The actual current-carrying capacity must be adjusted based on:

  • Ambient temperature: Higher temperatures require derating
  • Installation method: Bundled cables generate more heat
  • Duty cycle: Intermittent operation may allow higher currents
  • Cable grouping: Multiple cables in proximity reduce capacity

Consult DIN VDE 0298-4 derating tables for specific installation conditions.

Current-carrying capacity calculations: DIN VDE 0298-4 Application Guidelines

Electrical Testing Requirements

Test TypeYRDMY-JYRDMCY-J
AC Test Voltage2.5 kV2.0 kV
Test Duration5 minutes between conductors and earth
Pass CriteriaNo breakdown or flashover during test period

6. Detailed Technical Specifications

YRDMY-J Control Cables (Unscreened)

TypeConductors × Cross-sectionOuter Diameter (mm)Weight (kg/100m)Ampacity (A)Tensile Load (N)
1.5 mm² Cross-section
YRDMY-J4 G 1.57.0 – 7.610.518.090
YRDMY-J5 G 1.58.2 – 8.812.515.3110
YRDMY-J7 G 1.59.6 – 10.417.011.3160
YRDMY-J12 G 1.514.4 – 15.435.89.5270
YRDMY-J18 G 1.517.0 – 18.050.08.5400
YRDMY-J25 G 1.520.5 – 21.768.07.2560
2.5 mm² Cross-section
YRDMY-J4 G 2.58.8 – 9.415.026.0150
YRDMY-J5 G 2.59.4 – 10.218.022.1190
YRDMY-J7 G 2.511.7 – 12.525.216.4260
YRDMY-J12 G 2.517.3 – 18.353.913.8450
YRDMY-J18 G 2.522.2 – 23.883.312.2675
YRDMY-J25 G 2.524.8 – 26.4104.010.4940

YRDMY-J Power Cables (4-Core, 5-Core, and 7-Core)

TypeConductors × Cross-sectionOuter Diameter (mm)Weight (kg/100m)Ampacity (A)Tensile Load (N)
4-Core Power Cables
YRDMY-J4 G 410.5 – 11.323.034.0240
YRDMY-J4 G 612.6 – 13.433.844.0360
YRDMY-J4 G 1015.6 – 16.653.661.0600
YRDMY-J4 G 1619.3 – 20.985.482.0960
YRDMY-J4 G 2524.2 – 25.8131.0108.01,500
YRDMY-J4 G 3527.4 – 29.0178.5135.02,100
5-Core and 7-Core Power Cables
YRDMY-J5 G 411.5 – 12.326.928.9300
YRDMY-J7 G 413.8 – 14.636.321.4420
YRDMY-J7 G 616.8 – 17.856.027.7630

YRDMCY-J Screened Control Cables

TypeConductors × Cross-sectionOuter Diameter (mm)Weight (kg/100m)Ampacity (A)Tensile Load (N)
YRDMCY-J4 G 1.5 C9.1 – 9.715.318.060
YRDMCY-J5 G 1.5 C9.7 – 10.317.615.375
YRDMCY-J7 G 1.5 C12.4 – 13.226.811.3105
YRDMCY-J12 G 1.5 C16.7 – 17.744.19.5180
YRDMCY-J18 G 1.5 C19.8 – 21.060.88.5270
YRDMCY-J25 G 1.5 C23.3 – 24.988.17.2375

Note: “G” indicates inclusion of green/yellow protective earth conductor. “C” indicates copper braided screen.

7. Precautions for Use and Installation Guidelines

Installation Planning and Design

⚠️ Pre-Installation Assessment

Before installing YRDMY-J or YRDMCY-J cables, conduct a thorough assessment of:

  • Travel distance: Determine maximum cable length required
  • Travel speed: Ensure application stays within 150 m/min limit
  • Acceleration forces: Low to medium forces are suitable for these cables
  • Environmental conditions: Temperature, UV exposure, chemical presence, humidity
  • Bending radius: Ensure energy chain design allows minimum 7.5× cable diameter
  • Tensile loads: Calculate expected loads and verify they remain below 15 N/mm²

Handling and Storage

Proper Handling Techniques:

  • Avoid sharp bends: Never bend cable tighter than 7.5× diameter even during installation
  • Protect from damage: Prevent crushing, impact, or abrasion during transport and storage
  • Storage conditions: Store in dry location at temperatures between -15°C and +40°C
  • Coil orientation: Maintain drum orientation to prevent cable twist during unwinding
  • UV protection: While sheath is UV-resistant, avoid prolonged direct sunlight exposure during storage

Installation Best Practices

🔧 Energy Chain Installation:

  1. Cable Selection: Choose appropriate conductor count and cross-section based on power requirements and mechanical loads
  2. Chain Sizing: Select energy chain with internal dimensions providing adequate clearance (typically 10-20% larger than cable bundle)
  3. Bending Radius: Configure chain with radius ≥ 7.5× cable diameter – larger radii increase service life
  4. Cable Separation: Use dividers in chain to prevent cable-to-cable abrasion when running multiple cables
  5. Strain Relief: Install proper strain relief at both fixed and moving connection points
  6. Length Calculation: Account for additional cable length needed for chain movement (typically travel distance + radius calculations)
  7. Laying Direction: Install cables in neutral position (half-extended chain) to minimize pre-stress

🏗️ Festoon System Installation:

  1. Carrier Spacing: Position festoon carriers at appropriate intervals to prevent excessive cable sag
  2. Cable Support: Use smooth-surfaced saddles or carriers to prevent sheath abrasion
  3. Sag Management: Allow controlled sag between carriers – not too tight (excess tension) or too loose (excessive movement)
  4. End Connections: Provide adequate strain relief and weather protection at termination points
  5. Track Alignment: Ensure festoon track is straight and level to prevent binding
  6. Weight Distribution: Balance cable weight across carriers for smooth operation

Electrical Installation Precautions

⚡ Electrical Safety Requirements:

  • Voltage verification: Confirm operating voltage matches cable rating (600/1000V for YRDMY-J, 300/500V for YRDMCY-J)
  • Proper grounding: Connect green/yellow earth conductor to protective earth at both ends
  • Screen termination (YRDMCY-J): Ground copper screen at one end only to prevent ground loops (typically at supply end)
  • Ampacity verification: Ensure actual load current does not exceed rated ampacity for installation conditions
  • Termination quality: Use appropriate cable glands, properly sized to cable diameter
  • Circuit protection: Install overcurrent protection (fuses or circuit breakers) sized per cable ampacity
  • Isolation: De-energize system before installation or maintenance work

Environmental Considerations

ConditionSuitabilityPrecautions
Indoor Use✓ ExcellentPrimary application – no special precautions needed
Outdoor Use✓ Good (UV-resistant)Provide weather protection at connection points; consider additional UV shielding for extreme sun exposure
Humid Environments✓ GoodCable is moisture-resistant; ensure proper sealing at terminations
Oil Exposure✓ Good (oil-resistant)PVC sheath resists mineral oils and hydraulic fluids commonly found in industrial settings
Chemical Exposure⚠ LimitedNot suitable for strong acids, alkalis, or solvents – consult manufacturer for specific chemicals
Low Temperature⚠ Limited below -5°C (flexing)PVC becomes stiff below -5°C – not recommended for flexing applications in extreme cold

Maintenance and Inspection

Regular Maintenance Schedule:

  • Visual inspection: Monthly examination for sheath damage, abrasion, or deformation
  • Mechanical check: Quarterly assessment of cable movement, checking for binding or excessive wear
  • Electrical testing: Annual insulation resistance testing (recommended 1000V megger test)
  • Connection inspection: Semi-annual check of terminations for looseness or corrosion
  • Chain/carrier inspection: Regular examination of energy chain or festoon carrier condition
  • Documentation: Maintain inspection records and note any degradation trends

⚠️ Replacement Criteria:

Replace cable immediately if any of the following conditions are observed:

  • Visible conductor exposure through damaged sheath
  • Severe abrasion (>25% sheath thickness reduction)
  • Insulation resistance below 1 MΩ
  • Permanent cable deformation or kinking
  • Broken or severed conductors
  • Heat damage or melting of sheath
  • Contamination by incompatible chemicals

8. Common Problems and Troubleshooting

Problem 1: Premature Cable Failure

SymptomLikely CauseSolution
Cable breaks after short service life • Bending radius too small
• Excessive travel speed
• Improper installation
• Verify chain radius ≥ 7.5× cable ∅
• Check travel speed ≤ 150 m/min
• Review installation procedures
Conductor breakage at connections • Inadequate strain relief
• Excessive tensile load
• Vibration at termination
• Install proper strain relief devices
• Reduce load or use heavier cable
• Secure termination points firmly
Sheath cracking or splitting • Temperature below -5°C during flexing
• Chemical contamination
• Ozone exposure
• Provide heating or insulation
• Protect from incompatible chemicals
• Limit ozone exposure

Problem 2: Corkscrewing or Cable Twisting

Description:

Cable develops spiral twist or corkscrew shape during operation, potentially causing jamming in energy chain or excessive wear.

Causes:

  • Incorrect cable installation with pre-twist
  • Using standard (non-reverse-lay) cables instead of YRDMY-J/YRDMCY-J
  • Improper unwinding from drum during installation
  • Chain design forcing rotation

Prevention/Solution:

  • Verify cable is genuine YRDMY-J/YRDMCY-J with twist-free stranding
  • Install cable in neutral position without pre-twist
  • Unwind cable properly from drum (don’t roll drum on ground)
  • Check energy chain design allows free movement without rotation
  • Replace with properly designed cable if corkscrewing persists

Problem 3: Electromagnetic Interference (EMI)

SymptomLikely CauseSolution
Control signal errors or noise • Using unscreened YRDMY-J in EMI environment
• Screen not properly grounded
• Screen grounded at both ends (ground loop)
• Upgrade to screened YRDMCY-J cable
• Verify screen connection to protective earth
• Ground screen at supply end only
Equipment malfunction near VFDs • Power and control cables in same chain
• Inadequate separation
• High-frequency switching noise
• Use chain dividers to separate power/control
• Use YRDMCY-J screened cables
• Install ferrite filters if necessary

Problem 4: Overheating

Description:

Cable becomes excessively hot during operation, potentially leading to insulation damage or premature failure.

Causes:

  • Current exceeds rated ampacity for installation conditions
  • Inadequate heat dissipation in enclosed energy chain
  • Ambient temperature above design limits (+80°C max)
  • Multiple cables bundled without derating
  • Poor connections causing high resistance

Solutions:

  • Measure actual conductor temperature – must not exceed +70°C
  • Reduce load current or upgrade to larger conductor size
  • Apply derating factors per DIN VDE 0298-4 for bundled cables
  • Improve ventilation in energy chain if possible
  • Check and tighten all terminations
  • Consider forced cooling if ambient temperature is high

Problem 5: Water Ingress at Terminations

Description:

Moisture enters cable at connection points, causing insulation resistance degradation or corrosion.

Prevention:

  • Use weather-rated cable glands with proper IP rating (IP65 or higher for outdoor)
  • Install glands correctly with appropriate compression
  • Apply cable entry sealing compound or heat-shrink boots
  • Position connection boxes with cable entries facing downward
  • Regularly inspect seals and glands for degradation

Remedy if Water Ingress Occurs:

  • De-energize circuit immediately
  • Remove water and dry cable thoroughly
  • Test insulation resistance before re-energizing
  • Replace cable if insulation resistance below 1 MΩ
  • Improve sealing before returning to service

Problem 6: Reduced Service Life

ObservationContributing FactorsImprovement Actions
Cable life shorter than expected • High acceleration/deceleration rates
• Frequent starts and stops
• 24/7 continuous operation
• Reduce acceleration rates if possible
• Use larger bending radius
• Schedule periodic replacement based on cycles
Excessive sheath wear • Abrasive environment
• Sharp edges in chain
• Contamination with abrasive particles
• Clean chain regularly
• Inspect for sharp edges and remove
• Consider additional protective sleeving
Inconsistent failure patterns • Poor quality installation
• Mixing cable types
• Non-genuine replacement cables
• Use only trained installers
• Use consistent cable specifications
• Source cables from authorized suppliers

9. Selection Guide: When to Use YRDMY-J vs. YRDMCY-J

Choose YRDMY-J (Unscreened) When:

  • Application is primarily power transmission (motors, heaters, lighting)
  • EMI environment is minimal
  • Higher voltage required (up to 1000V)
  • Cost optimization is priority
  • No sensitive control or data signals present

Choose YRDMCY-J (Screened) When:

  • Application involves sensitive control signals
  • Near variable frequency drives (VFDs) or motor controllers
  • EMI/RFI protection is critical
  • Control automation or PLC systems involved
  • Mixed power and signal cable routing

10. Quality Assurance and Certification

Anhui Feichun Special Cable Co., Ltd. Quality Commitment:

All YRDMY-J and YRDMCY-J cables undergo rigorous quality control and testing procedures:

  • 100% electrical testing: Every cable length tested for conductor continuity, insulation resistance, and voltage withstand
  • Mechanical testing: Sample batch testing for tensile strength, bending cycles, and abrasion resistance
  • Flame retardant certification: IEC 60332-1 compliance verified by independent testing laboratories
  • Material verification: Incoming inspection of raw materials ensures consistent quality
  • Manufacturing controls: ISO-certified production processes with continuous monitoring
  • Traceability: Every cable reel marked with production date, batch number, and specifications

Conclusion

The YRDMY-J and YRDMCY-J cables from Anhui Feichun Special Cable Co., Ltd. represent advanced engineering solutions for demanding continuous-flex applications. Their specialized construction featuring twist-free stranding, short lay pitch, bending-resistant PVC sheath, and center stress relief elements ensures exceptional durability and reliability in energy guiding chains and festoon systems.

Compliance with international standards including DIN VDE 0250, IEC 60332-1, and IEC 60228 guarantees these cables meet the highest safety and performance requirements. Whether powering cranes, material handling equipment, irrigation systems, or industrial automation, these cables deliver consistent performance across millions of bending cycles.

For optimal results: Select the appropriate cable type (unscreened YRDMY-J or screened YRDMCY-J), properly size conductors based on current requirements, install with adequate bending radius (≥7.5× cable diameter), and follow manufacturer’s installation and maintenance guidelines. Regular inspection and adherence to operating parameters will ensure maximum service life and safe operation.

Technical information compiled from product specifications and industry standards including: Prysmian Chain Operation Cables, VAHLE Cable Carrier Cables, and TRATOS Festoon Systems

© 2025 Anhui Feichun Special Cable Co., Ltd. All rights reserved.

This technical documentation is provided for informational purposes. Always consult latest product datasheets and local electrical codes for specific applications.

Previous Article

What is 12YHRDC11YH Cable?

Next Article

What is a (N)GRDGOEU / (N)GRDCGOEU Cable?

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注