UK and Harmonized CENELEC Coding Cross References: BS 6004 vs EN 50525-2-31 Cable

Comprehensive Technical Analysis and Standards Comparison

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
UK and Harmonized CENELEC Coding Cross References: BS 6004 vs EN 50525-2-31 Cable | Feichun Cables

UK and Harmonized CENELEC Coding Cross References: BS 6004 vs EN 50525-2-31 Cable

Comprehensive Technical Analysis and Standards Comparison
Published by: Anhui Feichun Special Cable Co., Ltd. (安徽飞纯特种电缆有限公司)
Last Updated: November 2025

About Anhui Feichun Special Cable Co., Ltd.

Anhui Feichun Special Cable Co., Ltd. is a leading manufacturer of high-quality electrical cables, specializing in BS, IEC, and CENELEC standard cables for industrial, commercial, and residential applications. With state-of-the-art manufacturing facilities and rigorous quality control, we deliver reliable cable solutions that meet international safety and performance standards.

Executive Summary

The transition from traditional UK cable coding systems to harmonized European CENELEC standards represents a significant evolution in electrical cable specifications. The British Standard BS 6004, which has long governed PVC-insulated cables for voltages up to 300/500V in the United Kingdom, has been progressively superseded by the harmonized European standard EN 50525-2-31. This comprehensive technical guide examines the cross-references between these standards, providing detailed analysis of cable designations, specifications, applications, and compliance requirements essential for electrical engineers, contractors, and procurement professionals.

According to the official BS 6004:2012+A1:2020 standard documentation[1], Annex A provides critical guidance on cross-referencing traditional United Kingdom Cable Codes (formerly CMA codes) with harmonized CENELEC codes, while Annex B details the transfer of traditional UK cables to BS EN 50525 series. Understanding these relationships is fundamental for specification accuracy, procurement efficiency, and regulatory compliance in modern electrical installations.

Understanding BS 6004 and EN 50525-2-31 Standards

BS 6004: Traditional UK Cable Standard

BS 6004 specifies requirements and test methods for PVC-insulated and PVC-sheathed cables designed for electric power and lighting applications[2]. The standard encompasses cables with polyvinyl chloride (PVC) insulation rated at 300/500V, primarily intended for fixed installation in domestic and light industrial environments. These cables have been the backbone of UK electrical infrastructure for decades, with designation codes such as 6242Y (flat twin and earth) and 6181Y (single core) becoming ubiquitous in the British electrical industry.

Key Technical Specifications – BS 6004

ParameterSpecification
Voltage Rating (U₀/U)300/500V
Conductor MaterialPlain annealed copper (Class 1 or Class 2 per BS EN 60228)
Insulation TypePVC Type TI 1 (Thermoplastic)
Sheath MaterialPVC Type 6 (per BS 7655-4.2)
Operating Temperature Range-5°C to +70°C
Minimum Bending Radius (Fixed)6 × overall diameter
Conductor Sizes1.0mm² to 35mm² (varies by cable type)
Test Voltage (AC, 5 minutes)2000V for 300/500V cables

EN 50525-2-31: Harmonized European Standard

EN 50525-2-31 is part of the comprehensive EN 50525 series that provides harmonized specifications for low voltage energy cables across CENELEC member countries[3]. This standard specifically addresses single-core non-sheathed cables with thermoplastic PVC insulation for fixed wiring applications. The harmonization enables consistent cable specifications across European markets, facilitating international trade and ensuring uniform safety standards.

The EN 50525-2-31 standard applies to cables with rated voltages U₀/U up to 450/750V, representing a higher voltage classification than traditional BS 6004 cables. Notably, cables rated at 450/750V may be utilized at 600/1000V when installed in fixed installations with mechanical protection, within switchgear and control gear assemblies, as specified in HD 516[4].

Key Technical Specifications – EN 50525-2-31

ParameterSpecification
Voltage Rating (U₀/U)450/750V (300/500V for H05 series)
Conductor MaterialCopper (Class 1, 2, or 5 per EN 60228)
Insulation TypePVC (V types: 70°C; V2 types: 90°C)
SheathNon-sheathed (single core)
Maximum Conductor Temperature70°C (V types), 90°C (V2 types)
ApplicationFixed wiring in conduits, trunking, or embedded installations
Conductor Sizes0.5mm² to 630mm² (depending on cable type)
Compliance StandardsLow Voltage Directive 2014/35/EU, RoHS 2015/65/EU, REACH EC 1907/2006

Detailed Code Cross-Reference Analysis

The evolution from BS 6004 to EN 50525-2-31 necessitates a comprehensive understanding of code conversions to ensure specification accuracy and procurement continuity. The following analysis provides detailed cross-referencing between UK traditional codes and harmonized CENELEC designations, based on official standard documentation.

Primary Cross-Reference Table: BS 6004 to EN 50525-2-31

BS 6004 LocationNew LocationUK CodeCENELEC Harmonized CodeVoltage Rating
Table 4a (BS 6004:2000)BS EN 50525-2-31, Clause 4.16491XH07V-U / H07V-R450/750V
Table 4b (BS 6004:2000)BS EN 50525-2-31, Clause 4.26491XH07V-K450/750V
Table 5 (BS 6004:2000)BS EN 50525-2-31, Clause 4.32491XH05V-U / H05V-R300/500V
Table 5 (BS 6004:2000)BS EN 50525-2-31, Clause 4.42491XH05V-K300/500V
Table 11a (BS 6004:2000)BS EN 50525-2-31, Clause 5.16491XHRH07V2-U / H07V2-R450/750V (90°C)
Table 11b (BS 6004:2000)BS EN 50525-2-31, Clause 5.26491XHRH07V2-K450/750V (90°C)
Table 12 (BS 6004:2000)BS EN 50525-2-31, Clause 5.3, 5.42491XHRH05V2-U / H05V2-R / H05V2-K300/500V (90°C)

UK-Specific Cable Types Retained in BS 6004:2012

Certain traditional UK cable types have been retained within BS 6004:2012 without direct CENELEC equivalents due to their specific application requirements in the UK market. These cables remain governed exclusively by the national standard:

BS 6004:2012 TableUK CodeDescriptionTypical Applications
Table 36181Y, 6192Y, 6193YSingle core, twin, and three-core circular cablesMeter tails, sub-main distribution
Table 46241Y, 6242Y, 6243YFlat cables with circuit protective conductorDomestic fixed wiring (twin & earth)
Table 56192Y, 6241Y, 6242YArctic grade cables (-40°C rated)Cold storage facilities, outdoor installations

Understanding CENELEC Harmonized Code Structure

The harmonized CENELEC code designation follows a systematic structure that conveys critical cable specifications. Understanding this nomenclature is essential for proper cable selection and specification:

Code Structure: H07V-U

  • H = Harmonized (CENELEC standard)
  • 07 = Voltage rating 450/750V (05 = 300/500V, 03 = 300/300V)
  • V = PVC insulation (70°C rated); V2 = PVC (90°C rated)
  • U = Conductor type: Class 1 (solid); R = Class 2 (stranded); K = Class 5 (flexible)

Additional Suffixes

  • -F = Flexible cable with sheath
  • H2 = Flat non-separable construction
  • Z = LSZH (Low Smoke Zero Halogen) compound
  • Z1 = Halogen-free thermoplastic insulation

Important Withdrawal Notice

Certain cable types previously specified in BS 6004:2000 have been formally withdrawn and are no longer manufactured or specified. Notably, cables designated in Table 10a (H07V3-U/R) and Table 10b (H07V3-K) have been withdrawn. Specifications should be updated to reflect current standards, using equivalent cables from BS EN 50525-2-31 where direct replacements are available.

Technical Characteristics and Material Structure

Conductor Construction and Classification

Both BS 6004 and EN 50525-2-31 standards specify conductors manufactured from plain annealed copper conforming to BS EN 60228 (equivalent to IEC 60228)[5]. The conductor classification directly impacts cable flexibility and application suitability:

Conductor ClassConstructionTypical Size RangeApplicationCode Suffix
Class 1Solid conductor1.0mm² to 2.5mm²Fixed installations, minimal movement-U
Class 2Stranded conductor (7-61 wires)1.5mm² to 630mm²Fixed installations, moderate flexibility-R
Class 5Flexible conductor (multiple fine wires)0.5mm² to 240mm²Flexible connections, frequent movement-K

Insulation Material Properties

The insulation compound is critical for electrical performance, thermal management, and longevity. Both standards employ PVC insulation compounds, but with different thermal ratings and performance characteristics:

PVC Insulation Compound Specifications

PropertyV Type (Standard PVC)V2 Type (Heat-Resistant PVC)Test Standard
Maximum Conductor Temperature70°C90°CEN 50525-1
Short Circuit Temperature (Max 5s)160°C160°CIEC 60364-5-52
Tensile Strength (Minimum)12.5 MPa12.5 MPaEN 60811-501
Elongation at Break (Minimum)150%150%EN 60811-501
Volume Resistivity≥10¹² Ω·m≥10¹² Ω·mIEC 60093
Dielectric Strength≥15 kV/mm≥15 kV/mmIEC 60243-1

Sheath Construction (BS 6004 Cables)

BS 6004 sheathed cable types incorporate an outer PVC sheath (Type 6 per BS 7655-4.2) that provides additional mechanical protection and environmental resistance. The sheath compound specifications include:

Material DesignationPVC Type 6 (Thermoplastic)
Typical Thickness0.8mm to 1.8mm (varies with cable diameter)
Tensile Strength (Minimum)10.5 MPa
Elongation at Break (Minimum)125%
Cold Bend Test-5°C (standard grade); -40°C (Arctic grade)
Resistance to OilPer BS 7655-4.2 requirements

Dimensional Specifications and Tolerances

Precise dimensional control is essential for ensuring proper installation in conduits, trunking, and accessories. The following table presents nominal dimensions for common cable sizes in both standards:

Conductor SizeBS 6004 (6242Y) Overall DimensionsEN 50525-2-31 (H07V-R) Overall DiameterApproximate Weight (kg/km)
1.0mm²6.1mm × 7.8mm (flat)2.9mm17.5 (single core)
1.5mm²6.5mm × 8.1mm (flat)3.2mm24.0 (single core)
2.5mm²7.2mm × 9.1mm (flat)3.9mm36.5 (single core)
4.0mm²8.4mm × 10.8mm (flat)4.8mm56.0 (single core)
6.0mm²9.6mm × 12.2mm (flat)5.6mm79.5 (single core)
10.0mm²11.5mm × 14.8mm (flat)7.0mm126.0 (single core)
16.0mm²13.8mm × 17.8mm (flat)8.6mm195.0 (single core)

Electrical Performance Parameters

Current Carrying Capacity (Ampacity)

The current carrying capacity of cables is influenced by multiple factors including conductor size, installation method, ambient temperature, and grouping arrangements. The following data represents typical ampacity values for single-core cables installed in standard conditions (30°C ambient, reference installation method C – clipped direct):

Conductor SizeBS 6004 Current Rating (A)EN 50525-2-31 (70°C) Current Rating (A)EN 50525-2-31 (90°C) Current Rating (A)
1.0mm²11 / 13.5 / 15.5*1315
1.5mm²14.5 / 17.5 / 19.5*17.520
2.5mm²20 / 24 / 27*2427
4.0mm²26 / 32 / 36*3237
6.0mm²34 / 41 / 46*4148
10.0mm²46 / 57 / 63*5766
16.0mm²61 / 76 / 85*7688
25.0mm²80 / 101 / 112*101117

* Values represent different installation methods as per BS 7671 (clipped direct / enclosed in conduit / buried in masonry)

Voltage Drop Characteristics

Voltage drop calculations are essential for ensuring adequate voltage at load terminals, particularly in long cable runs. The following table presents voltage drop values in millivolts per ampere per meter (mV/A/m) for copper conductors at 70°C operating temperature:

Conductor SizeResistance (mΩ/m at 20°C)Reactance (mΩ/m at 50Hz)Voltage Drop AC Single Phase (mV/A/m)Voltage Drop AC Three Phase (mV/A/m)
1.0mm²18.10.1454438
1.5mm²12.10.1402925
2.5mm²7.410.1351815
4.0mm²4.610.130119.5
6.0mm²3.080.1257.36.4
10.0mm²1.830.1204.43.8
16.0mm²1.150.1152.82.4
25.0mm²0.7270.1101.751.50

Insulation Resistance and Dielectric Testing

Both standards mandate rigorous testing to ensure electrical safety and insulation integrity. Key test parameters include:

Minimum Insulation Resistance (at 20°C)≥100 MΩ·km (for 300/500V); ≥50 MΩ·km (for 450/750V)
Type Test Voltage (AC, 5 minutes)2000V (for 300/500V cables); 2500V (for 450/750V cables)
Sample Test Voltage (AC, 1 minute)1500V (for 300/500V cables); 2000V (for 450/750V cables)
Partial Discharge Test≤10 pC at 1.5 × U₀ (for specified cable types)
Test Frequency48-62 Hz (typically 50Hz in Europe)

Applications and Installation Guidelines

Typical Application Scenarios

BS 6004 and EN 50525-2-31 cables serve diverse applications across residential, commercial, and industrial sectors. Understanding appropriate application contexts ensures optimal cable selection and installation practices:

Residential Applications

  • Final circuit wiring for lighting installations
  • Socket outlet circuits (ring and radial configurations)
  • Fixed appliance connections (ovens, immersion heaters)
  • Shower circuits and bathroom installations
  • Meter tails and consumer unit connections (6181Y)
  • Distribution board interconnections

Commercial & Industrial Applications

  • Building management system cabling
  • Lighting control and emergency lighting circuits
  • HVAC system power distribution
  • Control panel internal wiring
  • Machinery fixed wiring connections
  • Sub-distribution between switchgear

Specialized Applications

  • Cold storage facilities (Arctic grade cables)
  • Agricultural buildings and farm installations
  • Temporary building services
  • Refurbishment and retrofit projects
  • Industrial control circuits
  • Emergency power systems

Installation Methods and Environment Suitability

Proper installation method selection is critical for cable longevity, performance, and compliance with electrical regulations. The following table outlines approved installation methods per BS 7671 (IET Wiring Regulations):

Installation MethodBS 7671 ReferenceSuitabilityDerating Factor Range
Clipped direct to surfaceMethod 20 (flat) / Method C (single)Indoor dry locations, non-corrosive0.85 – 1.00
In conduit on wall or embeddedMethod A, BMechanical protection required0.70 – 0.95
In trunkingMethod BMultiple circuits, easy modification0.70 – 0.95
In free airMethod E, FWell-ventilated areas0.90 – 1.00
Buried in masonryMethod AConcealed fixed wiring0.50 – 0.80
On cable tray (perforated)Method EIndustrial installations0.90 – 1.00

Installation Restrictions and Limitations

These cables are NOT suitable for:

  • Direct burial underground without additional protection
  • Outdoor exposure without appropriate mechanical protection
  • Continuous immersion in water or corrosive substances
  • Areas with sustained temperatures exceeding 70°C (or 90°C for V2 types)
  • Locations subject to mechanical impact without conduit/trunking
  • Flexible connections requiring frequent movement (use flexible cables instead)
  • Environments requiring halogen-free or low smoke properties (use LSZH alternatives like BS EN 50525-3-31 or 3-41)

Special Considerations for Mining and Industrial Applications

For specialized industrial applications, including mining operations, Amplex Mining provides comprehensive AS/NZS compliant mining cable solutions, specifically engineered for harsh underground environments and demanding operational conditions. These applications often require cables with enhanced mechanical strength, flame retardance, and resistance to oils and chemicals beyond standard BS 6004 or EN 50525-2-31 specifications.

Similarly, for mobile machinery and port terminal applications requiring exceptional flexibility and durability, Reeling Cable offers specialized solutions for cable reels and festoon systems, designed to withstand high mechanical stress, frequent bending operations, and harsh maritime environments with salt spray exposure.

Safety Standards and Compliance Requirements

Regulatory Framework

Electrical cables manufactured to BS 6004 and EN 50525-2-31 must demonstrate compliance with multiple regulatory frameworks to ensure market access and installation safety across UK and European markets:

Key Regulatory Compliance Requirements

Low Voltage Directive 2014/35/EUMandates essential safety requirements for electrical equipment operating between 50-1000V AC. Compliance demonstrated through harmonized standards testing and CE marking.
RoHS Directive 2015/65/EURestricts use of hazardous substances including lead, mercury, cadmium, hexavalent chromium, and specific brominated flame retardants. Maximum concentration values: 0.1% for most substances, 0.01% for cadmium.
REACH Regulation EC 1907/2006Registration, Evaluation, Authorization of Chemicals. Requires manufacturer compliance with substance restrictions and disclosure of Substances of Very High Concern (SVHC) exceeding 0.1% w/w.
CPR Regulation EU 305/2011Construction Products Regulation mandates performance declaration and classification for cables used in construction works. Fire performance classes: Aca, B1ca, B2ca, Cca, Dca, Eca, Fca per EN 13501-6.
BS 7671:2018+A2:2022 (IET Wiring Regulations)UK national standard for electrical installations, incorporating requirements for cable selection, sizing, installation methods, and protection coordination.

Type Testing and Certification

Cables conforming to BS 6004 and EN 50525-2-31 must undergo comprehensive type testing by accredited laboratories to verify compliance with standard requirements. In the UK, BASEC (British Approvals Service for Cables) provides independent third-party certification[6]:

Test CategorySpecific TestsAcceptance CriteriaTest Standard
Electrical TestsConductor resistance, insulation resistance, voltage withstand, partial dischargePer standard specifications for each cable typeEN 60811-401, EN 60811-402
Mechanical TestsTensile strength, elongation, impact resistance, flexing durabilityMinimum values specified in standard tablesEN 60811-501, EN 60811-502
Thermal TestsHeat aging, pressure at elevated temperature, cold bendRetention of ≥80% initial properties after agingEN 60811-401, EN 60811-505
Fire PerformanceFlame propagation, smoke emission, gas acidity (if applicable)Classification per EN 50575 / EN 13501-6EN 60332-1-2, IEC 61034-2
Environmental TestsOzone resistance, oil resistance, mineral oil immersionNo cracking or degradation after exposureEN 60811-404, EN 60811-505

Installation Safety Guidelines

Safe installation practices are paramount to ensure electrical system integrity and user safety. The following guidelines align with BS 7671 requirements and industry best practices:

Circuit Protection Requirements

  • Overcurrent protection devices (MCBs/RCBOs) must be correctly rated
  • Maximum protective device rating ≤ cable current carrying capacity × applicable correction factors
  • Circuit Protective Conductor (CPC) sizing per BS 7671 Table 54.7
  • Earth fault loop impedance verification: Zs ≤ maximum permitted values
  • RCD protection mandatory for socket outlets ≤20A and buried cables ≤50mm depth

Installation Best Practices

  • Minimum bending radius: 6 × overall cable diameter (fixed installations)
  • Support spacing: ≤250mm vertical, ≤350mm horizontal for flat cables
  • Segregation from telecommunications cables: ≥50mm separation
  • Junction box/enclosure compliance: IP rating appropriate to environment
  • Termination practices: proper conductor preparation, torque settings per manufacturer
  • Cable identification: clear, durable labeling at termination and accessible points

Environmental Considerations

  • Ambient temperature derating: apply factors per BS 7671 Appendix 4
  • Thermal insulation contact: 50% derating when surrounded by insulation
  • Grouping factors: reduce current capacity for multiple circuits in close proximity
  • Soil thermal resistivity: consider for buried installations (2.5 K·m/W standard)
  • UV exposure protection: use appropriate conduit/trunking for outdoor runs

Periodic Inspection and Testing

Installed cables require periodic inspection and testing per BS 7671 Part 6 to maintain safety and compliance. Recommended inspection intervals: 5 years for domestic installations, 3 years for commercial, 1 year for industrial environments with severe operating conditions.

Common Issues and Troubleshooting

Identification of Cable Degradation

Regular visual inspection and electrical testing can identify potential cable failures before they result in system downtime or safety hazards. Common degradation indicators include:

SymptomPossible CauseDiagnostic MethodRecommended Action
Discoloration of insulationThermal overload, UV exposureVisual inspection, thermal imagingCheck circuit loading, verify protection device sizing, replace if severe
Hardening or cracking of sheathAging, excessive temperature, chemical exposurePhysical examination, bend testReplace cable; investigate environmental factors
Reduced insulation resistanceMoisture ingress, insulation degradationMegger test (500V or 1000V DC)If IR < 1 MΩ, investigate and replace; verify termination integrity
Intermittent faultsLoose connections, conductor fractureContinuity test, visual termination inspectionRe-terminate connections with correct torque; replace cable if conductor damaged
Excessive voltage dropUndersized cable, high resistance connections, long runsVoltage measurement under load, conductor resistance testVerify cable sizing calculations; check all terminations; consider parallel runs
Circuit breaker nuisance trippingOverloading, insulation failure, moistureLoad current measurement, IR testing, RCD ramp testRedistribute loads; investigate earth leakage; replace damaged cable sections

Installation Error Prevention

Critical Installation Errors to Avoid

  • Insufficient cable sizing: Always verify current carrying capacity considering all derating factors. Undersized cables risk thermal damage and fire hazards.
  • Excessive bending radius violation: Respect minimum bending radius (6 × OD) to prevent insulation stress and conductor damage.
  • Incorrect CPC sizing: Circuit Protective Conductor must meet minimum cross-sectional area per BS 7671 Table 54.7 for effective fault protection.
  • Inadequate mechanical protection: Use appropriate conduit or trunking where cables are exposed to mechanical damage.
  • Poor termination practices: Ensure proper conductor preparation, use correct terminal types, and apply manufacturer-specified torque settings.
  • Mixing cable types: Do not interchange BS 6004 and EN 50525-2-31 cables within single circuits without ensuring voltage and current compatibility.

Fault Diagnosis Procedures

Systematic fault diagnosis minimizes downtime and ensures accurate problem resolution. Recommended diagnostic sequence:

  1. Visual Inspection: Examine cable routing, terminations, and visible insulation for damage or overheating signs.
  2. Continuity Testing: Verify conductor continuity using low-resistance ohmmeter; identify open circuits or high-resistance joints.
  3. Insulation Resistance Testing: Conduct IR testing per BS 7671 Section 643 using appropriate test voltage (typically 500V DC for 300/500V circuits).
  4. Earth Fault Loop Impedance: Measure Zs to ensure protective device disconnection times meet requirements.
  5. Polarity Verification: Confirm correct phase, neutral, and earth conductor connections.
  6. RCD Testing: Test residual current devices for correct trip current and operating time.
  7. Load Testing: Measure circuit current and voltage drop under normal operating conditions.

Procurement and Specification Guidance

Cable Specification Best Practices

Accurate cable specification is essential for procurement efficiency, cost optimization, and installation success. A comprehensive cable specification should include the following parameters:

Essential Specification Elements

  • Standard reference: BS 6004:2012+A1:2020 or BS EN 50525-2-31:2011
  • Cable designation code: e.g., 6242Y, H07V-R, 6491X
  • Voltage rating: 300/500V or 450/750V
  • Conductor size: Specify in mm² (e.g., 2.5mm²)
  • Conductor class: Class 1 (solid), Class 2 (stranded), or Class 5 (flexible)
  • Number of cores: Single, twin, three-core, etc.
  • Insulation/sheath color: Per standard or specify requirements
  • Reel/drum length: Standard lengths or specify custom requirements

Quality Assurance Requirements

  • Certification: BASEC, ASTA, or equivalent third-party certification
  • Test reports: Request routine test certificates for quality verification
  • Traceability: Continuous meter marking for installation documentation
  • Packaging: Suitable drums/reels for site handling and storage
  • Documentation: Compliance certificates, DoP (Declaration of Performance)
  • Manufacturer quality system: ISO 9001:2015 certification preferred

Cost Optimization Strategies

  • Volume purchasing: Consolidate requirements for better pricing
  • Standard lengths: Minimize custom lengths to reduce waste
  • Alternative specifications: Verify if EN 50525-2-31 can substitute BS 6004
  • Just-in-time delivery: Coordinate with installation schedule
  • Approved supplier lists: Pre-qualify manufacturers for consistent quality
  • Long-term agreements: Establish framework contracts for price stability

Sample Cable Designation Specifications

Example Procurement Specifications

ApplicationSpecificationAlternative (Harmonized)
Domestic lighting circuitBS 6004 6242Y 1.5mm² Twin & Earth, Class 1 conductor, Grey sheath, 100m drumNot directly applicable (sheathed cable)
Consumer unit tailsBS 6004 6181Y 25mm² Single Core, Class 2 conductor, Blue/Brown cores, 50m drumNot directly applicable (UK-specific application)
Fixed conduit wiringBS 6004 6491X 2.5mm² Single Core, Class 2 conductorBS EN 50525-2-31 H07V-R 2.5mm², Class 2 conductor, 450/750V
Control panel wiringBS 6004 6491X 1.5mm² Single Core, Class 1 conductorBS EN 50525-2-31 H07V-U 1.5mm², Class 1 conductor, 450/750V
Flexible internal connectionsBS 6004 2491X 1.0mm² Single Core, Class 5 conductorBS EN 50525-2-31 H05V-K 1.0mm², Class 5 conductor, 300/500V

Contact Anhui Feichun Special Cable Co., Ltd.

For technical specifications, custom cable solutions, or procurement inquiries, please contact our engineering team:

Technical Support [email protected]
Sales Inquiries [email protected]

We provide comprehensive technical support, custom cable design, and reliable delivery solutions for projects worldwide.

References

  1. BSI Standards Publication. (2020). BS 6004:2012+A1:2020 – Electric cables. PVC insulated and PVC sheathed cables for voltages up to and including 300/500 V, for electric power and lighting. British Standards Institution. https://www.en-standard.eu/bs-6004-2012-a1-2020
  2. Eland Cables. (2024). BS6004 Standard Cable Specifications and Technical Data. Retrieved from https://www.elandcables.com
  3. CENELEC. (2011). EN 50525-2-31:2011 – Electric cables – Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) – Part 2-31: Cables for general applications – Single core non-sheathed cables with thermoplastic PVC insulation. European Committee for Electrotechnical Standardization.
  4. Tratos Group. (2024). BS EN 50525-2-31 Technical Specifications and Applications. Retrieved from https://tratosgroup.com
  5. IEC. (2023). IEC 60228:2023 – Conductors of insulated cables. International Electrotechnical Commission. https://webstore.iec.ch
  6. BASEC. (2024). Cable Certification and Testing Services. British Approvals Service for Cables. Retrieved from https://www.basec.org.uk
  7. Institution of Engineering and Technology. (2022). BS 7671:2018+A2:2022 – Requirements for Electrical Installations (IET Wiring Regulations). 18th Edition with Amendment 2. https://electrical.theiet.org
  8. European Commission. (2023). Commission Implementing Decision (EU) 2023/2723 on harmonised standards for electrical equipment. Official Journal of the European Union. https://eur-lex.europa.eu

Anhui Feichun Special Cable Co., Ltd. (安徽飞纯特种电缆有限公司)

Professional Cable Manufacturer | BS, IEC, CENELEC Standards | ISO 9001:2015 Certified

© 2025 Anhui Feichun Special Cable Co., Ltd. All rights reserved.

This technical document is provided for informational purposes. Specifications subject to change. Always verify current standard requirements and consult qualified electrical engineers for specific installations.

Previous Article

Understanding NEC Article 400, Table 400.4: Complete Technical Guide to Flexible Cord and Cable Specifications

Next Article

What is YHKGXSekyn, YHKGXSekFtZnyn, YHKGXSekFtyn, YHKGXSekFitlyn, YHKGXSekFoyn, and YHKGXSekFpyn Polish Mining Cable ?

View Comments (1)

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注