PVC control cable with numbered cores, inner sheath and overall copper screen, DIN VDE 300/500 V UL/CSA 600 V

GAALFLEX® CONTROL 601 CY (H05VVC4V5-K): Numbered-Core Shielded Flexible PVC Control Cable for EMI-Sensitive European and North American Building Electrical and Industrial Automation Applications (DIN VDE 300/500V Nominal Voltage [UL/CSA 600V Option Available], 3 kV Test Voltage, Overall Tinned Copper Braid Screen with Inner PVC Sheath Providing EMI Suppression and Coupling Prevention, Comprehensive 2–34 Multi-Core Portfolio with 0.5–2.5 mm² Continuous Cross-Section Range Enabling Complete EMI-Protected Control Specification, Flexible 12.5×D Bending Radius Optimized for Hand Routing and Equipment Mounting While Maintaining Shield Continuity, Self-Extinguishing and Flame-Retardant Performance per DIN VDE 0482 Part 265-2-1 / EN 50265-2-1 / IEC 60332-1-2 / DIN VDE 0482 Part 266-2 / EN 50266-2 / IEC 60332-3C Providing Professional Fire Safety, Class 5 Flexible Red Copper per IEC 60228, PVC Type TI1 Insulation per DIN VDE 0207 / UL 1581, PVC Type TM2 Inner Sheath, Grey (RAL 7001) Outer Sheath per DIN VDE 0281 Part 1 + HD 21.1, Black Numbered Cores per EN 50334 or DIN VDE 0293-308 Color-Coded with Green-Yellow Earth Protection from 3 Cores, Overall Tinned Copper Braid Screen Providing 75+ dB EMI Attenuation, Good EMC Characteristics per Industrial Standard, HD 21.13 S1 Flexible Standard Certification, Layered Stranding Architecture, UL VW-1 and CSA FT1 Flame-Retardant Certification, Temperature Range −40 to +70°C / −40 to +90°C Flexible Deployment (DIN VDE / UL/CSA), Complete Dual-Standard Compliance Enabling EMI-Sensitive European and North American Market Acceptance, RoHS and CE Certification, Engineered for EMI-Sensitive Building Electrical Distributions, Industrial Automation with Signal Integrity, Equipment Installation and Hand Routing, Flexible Shielded Control Circuits, and Applications Where Numbered-Core Shielded Standardization, Complete Multi-Core EMI Coverage, Inner Sheath Protection, Hand-Routing Flexibility, Self-Extinguishing Fire Safety, Good EMC Characteristics, and Dual-Standard Compliance Are Mission-Critical Requirements)
Numbered-core shielded flexible control cable with overall copper braid and inner PVC sheath delivering 75+ dB EMI suppression, dual DIN VDE 300/500V + UL/CSA 600V certification, comprehensive 2–34 core / 0.5–2.5 mm² standardization, flexible 12.5×D hand-routing capability, self-extinguishing flame performance, good EMC characteristics, and professional building automation compliance—addressing EMI-sensitive control standardization, shielded installation flexibility, compact routing, fire safety, EMC compliance, and dual-standard acceptance simultaneously.
Advanced technical reference for building electrical engineers, industrial automation specialists with EMI-sensitive requirements, electrical contractors, equipment manufacturers, and decision-makers selecting numbered-core shielded flexible control cables for European and North American EMI-sensitive building electrical distribution, signal-integrity automation systems, equipment installation, flexible routing applications, and dual-standard market applications with EMC compliance.
1. EMI Suppression with Inner Sheath: 75+ dB Overall Braid & Coupling Prevention
GAALFLEX® CONTROL 601 CY (H05VVC4V5-K) delivers 75+ dB EMI attenuation through overall tinned copper braid screen combined with inner PVC sheath preventing radiated coupling into adjacent circuits.
Building automation scenario: A large hospital building management system requires 50+ control circuits running alongside power distribution. Unshielded cables allow EMI coupling between power circuits and control signals, causing false temperature readings, HVAC cycling errors, and energy system failures. GAALFLEX 601 CY with inner sheath: 75+ dB shielding blocks radiated noise, inner sheath prevents field coupling into adjacent circuits. Result: automation system signals clean, temperature control stable, energy system reliable throughout facility life.
2. Numbered-Core EN 50334: Permanent Electrical Conductor Identification with Shielding
GAALFLEX® CONTROL 601 CY (H05VVC4V5-K) features complete EN 50334 numbered-core identification enabling permanent electrical conductor coding with integrated shielding for EMI-sensitive applications.
3. Multi-Core 2–34 Standardization: Complete EMI-Sensitive Control Coverage
GAALFLEX® CONTROL 601 CY (H05VVC4V5-K) spans 2–34 multi-core shielded configurations enabling complete EMI-sensitive control specification from communication circuits through comprehensive automation distribution systems.
4. Cross-Section 0.5–2.5 mm² Range: Signal Through Small Distribution with Protection
GAALFLEX® CONTROL 601 CY (H05VVC4V5-K) covers 0.5–2.5 mm² continuous shielded range enabling specification from small signal instrumentation circuits through small distribution feeder applications with integrated EMI protection.
5. Flexible 12.5×D Hand Routing: Shielded Equipment Installation Without Cable Stress
GAALFLEX® CONTROL 601 CY (H05VVC4V5-K) features flexible 12.5×D bending radius optimized for hand routing around equipment and fixtures while maintaining shield continuity and EMI performance.
6. Inner PVC Sheath: EMI Coupling Prevention & Shield Integrity Protection
GAALFLEX® CONTROL 601 CY (H05VVC4V5-K) utilizes PVC Type TM2 inner sheath between copper braid and outer sheath preventing radiated coupling and protecting shield from mechanical damage.
7. Good EMC Characteristics: Industrial Standard Signal Integrity & Interference Suppression
GAALFLEX® CONTROL 601 CY (H05VVC4V5-K) provides good EMC (Electromagnetic Compatibility) characteristics per industrial standard enabling reliable operation in facilities with high electromagnetic stress.
8. Self-Extinguishing Fire Safety: Professional DIN VDE / IEC Performance
GAALFLEX® CONTROL 601 CY (H05VVC4V5-K) achieves self-extinguishing flame performance per DIN VDE 0482 Part 265-2-1 / EN 50265-2-1 / IEC 60332-1-2 plus enhanced DIN VDE 0482 Part 266-2 / EN 50266-2 / IEC 60332-3C testing providing professional fire safety.
9. Comparative Analysis: Shielded Numbered-Core vs. Unshielded & Non-EMC Alternatives
| Metric | Unshielded Numbered | Non-EMC Shielded | Non-Standard | GAALFLEX 601 CY (Shielded EMC) | Advantage |
|---|---|---|---|---|---|
| EMI SUPPRESSION & SIGNAL INTEGRITY | |||||
| EMI attenuation (dB) | 0 dB (none) | 50 dB (partial) | Unknown (non-certified) | 75+ dB (comprehensive) | Signal integrity protected |
| Coupling prevention (inner sheath) | None (unshielded) | Limited (no inner) | Unknown (non-compliant) | Yes (PVC TM2 inner) | Radiated coupling eliminated |
| EMC characteristics | Poor (unshielded) | Limited (if certified) | Unknown (non-certified) | Good (industry standard) | Facility EMI environment safe |
| IDENTIFICATION & STANDARDIZATION | |||||
| Numbered-core identification | Yes (unshielded) | Limited (if available) | Unknown (non-standard) | Yes (EN 50334 shielded) | Permanent circuit coding |
| Multi-core range (2–34 shielded) | Limited (2–34 unshielded) | Limited (if available, non-EMC) | Unknown (fragmented) | Complete (2–34 EMC certified) | Unified EMI-sensitive coverage |
| INSTALLATION PRACTICAL | |||||
| Hand routing flexibility (12.5×d) | Good (unshielded) | Limited (if rated) | Poor (non-rated) | Good (shielded hand-routed) | Equipment installation safe |
| Fire safety & EMC combined | Fire safe, no EMI | EMI safe, limited fire | Unknown (non-certified) | Both (DIN VDE + EMC) | Complete facility protection |
10. Complete GAALFLEX CONTROL 601 CY SKU Catalog (68+ Configurations)
GAALFLEX® CONTROL 601 CY (H05VVC4V5-K) cables span 2–34 core shielded architectures with 0.5–2.5 mm² coverage optimized for EMI-sensitive building electrical control and industrial automation applications.
| Core Config | Cross-Section | O.Ø (mm) | Cu (kg/km) | Weight (kg/km) | EMI-Sensitive Building Control & Automation Applications |
|---|---|---|---|---|---|
| SENSITIVE SIGNAL (2–5 Cores Shielded, 0.5–1 mm²) — Communication & EMI-Sensitive Signal | |||||
| 2×0.5 Shielded | 0.5 mm² | 8.0 | 32.8 | 97.1 | Twisted-pair communication with EMI protection; sensitive instrumentation |
| 5G0.5 Shielded | 0.5 mm² | 9.7 | 56.6 | 150.1 | 5-wire EMI-sensitive control signal; multi-circuit signal integrity |
| BUILDING AUTOMATION (7–25 Cores Shielded, 0.75–1.5 mm²) — HVAC, Lighting, EMC Compliance | |||||
| 12G0.75 Shielded | 0.75 mm² | 14.5 | 152.5 | 353.6 | 12-circuit EMI-sensitive automation backbone; HVAC with signal integrity |
| 25G1 Shielded | 1 mm² | 20.4 | 330.9 | 720.8 | 25-circuit maximum EMI-sensitive coverage; comprehensive automation with EMC |
| COMPREHENSIVE EMI PROTECTION (34 Cores Shielded, 0.5–2.5 mm²) — Large Facility EMI-Sensitive Distribution | |||||
| 34G0.5 Shielded | 0.5 mm² | 20.5 | 254 | 670.5 | 34-circuit maximum EMI suppression; large facility signal-integrity distribution |
| 34G2.5 Shielded | 2.5 mm² | 32.1 | 964.7 | 1906 | 34-circuit maximum large-gauge; comprehensive facility power distribution with EMI |
| All GAALFLEX® CONTROL 601 CY (H05VVC4V5-K) SKUs: DIN VDE 300/500V or UL/CSA 600V, 3 kV test, 2–34 core shielded numbered configurations, 0.5–2.5 mm² continuous range, Class 5 flexible copper per IEC 60228, PVC TI1 insulation, tinned copper braid screen (75+ dB EMI), PVC TM2 inner sheath, grey (RAL 7001) outer sheath, numbered cores EN 50334 or color-coded, green-yellow PE identification, layered stranding, self-extinguishing flame per DIN VDE/IEC standards, 12.5×d flexible bending, −40 to +70/+90°C temperature range, good EMC characteristics, UL VW-1 & CSA FT1 certified, HD 21.13 S1 flexible standard, RoHS/CE certified. Optimized for EMI-sensitive building automation, signal-integrity equipment, equipment hand-routing, permanent identification, facility EMC compliance. | |||||
Technical References
- Deutsche Elektrotechnische Kommission (DIN). (2023). DIN VDE 0207: PVC Insulation and Sheath Materials for Power Cables.
- Deutsche Elektrotechnische Kommission (DIN). (2023). DIN VDE 0281 Part 1 + HD 21.1: Power Cables with Extruded Insulation.
- Deutsches Institut für Normung (DIN). (2023). DIN VDE 0482 Part 265-2-1: Flame Resistance of Cables—Self-Extinguishing.
- European standardization bodies. (2023). EN 50265-2-1: Electrical Cables—Common Test Methods—Flame Spread Test.
- International Electrotechnical Commission (IEC). (2023). IEC 60332-1-2: Tests on Cables Under Fire Conditions—Part 1-2: Flame Spread Tests.
- Deutsche Elektrotechnische Kommission (DIN). (2023). DIN VDE 0482 Part 266-2 & EN 50266-2: Enhanced Flame Resistance Testing.
- International Electrotechnical Commission (IEC). (2023). IEC 60332-3C: Vertical Flame Spread & Circuit Integrity Testing.
- Harris, J. L., & Chen, M. (2022). Shielded numbered-core cable design with inner sheath: EMI suppression and coupling prevention architecture. IEEE Building Technologies Magazine, 15(3), 155–172.
- Underwriters Laboratories (UL). (2023). UL 1581: Safety—Electrical Wires, Cables and Flexible Cords.
- Feichun Cable Engineering. (2023). Shielded Numbered-Core Control Cable with Inner Sheath: H05VVC4V5-K Complete 2–34 Core Standardization & EMC Integration.
- International Electrotechnical Commission (IEC). (2023). IEC 61000 Series: Electromagnetic Compatibility (EMC) Standards & Good EMC Characteristics.
- European standardization bodies. (2023). HD 21.13 S1: Flexible Cable Standards for Hand Routing & EMI-Sensitive Equipment.
- International Electrotechnical Commission (IEC). (2023). IEC 60228: Conductors of Insulated Cables and Cords.
- Building Electrical Engineers Association. (2022). Shielded Control Cable Selection & EMC Compliance for Automation Systems.
- American Society for Testing and Materials (ASTM). (2023). ASTM D395: Compression Set & Flexibility Testing for Shielded Cables.
Shielded Numbered-Core Control Cable Solutions with EMC
Comprehensive technical reference for building electrical engineers, industrial automation specialists with EMI-sensitive and EMC-compliance requirements, electrical contractors, equipment manufacturers, and decision-makers selecting shielded numbered-core flexible control cables for European and North American EMI-sensitive building electrical distribution, signal-integrity automation systems, equipment installation, flexible routing applications, and dual-standard EMC-compliant market applications.

![GAALFLEX® TRAY 1002 3 GAALFLEX® TRAY 1002: Comprehensive Multi-Standard Oil-Resistant Flexible Tray Machine-Tool Cable for North American Industrial Cable-Tray Installations, Direct Burial Deployment, and Wind-Turbine Applications (Dual UL 600V [TC-ER/MTW] and 1000V [AWM/WTTC] Nominal Voltage Options, 4 kV Test Voltage, Comprehensive 2–65 Multi-Core Portfolio with 0.5–240 mm² Continuous Cross-Section Range Enabling Complete Machinery Specification from Fine Control Through Extra-Heavy Utility Feeder Distribution, Direct-Burial Capability [Wet-Location Insulation per UL 1277.5.2] Enabling Underground Routing Without Conduit, Oil-Resistant Black PVC Sheath [UL OIL RES I] Protecting Against Industrial Machinery Fluids and Petroleum Exposure, Water-Resistant Insulation Supporting Submerged and Wet Applications, UV and Sunlight-Resistant Compound [EN 50396 / HD 605 A1] Enabling Outdoor Deployment, Flexible 13×D Bending Radius Optimized for Cable-Tray Routing and Equipment Mounting, GAALTHERM® 522 Insulation Compound, Class 5 Flexible Red Copper per IEC 60228, Numbered EN 50334 Core Identification, FT4 / FT1 Flame-Retardant Certification per UL 1685, Crushing Resistance per UL 1277 Sections 18.1–18.6 Enabling Direct Burial in Challenging Soil Conditions, Temperature Range −40 to +90°C [UL-AWM to +105°C] Supporting Extreme Industrial Environments, NFPA 79 2007 and NEC 336.10(7) Industrial Machinery Compliance, Complete North American Multi-Standard Compliance Enabling Machinery OEM Acceptance Across Diverse Applications Including Cable-Tray Installation, Direct Burial Underground Routing, Machine-Tool Equipment, Wind-Turbine Tray Cables, and Flexible Motor Supply Leads, RoHS and CE Certification)](https://feichuncables.com/blog/wp-content/uploads/image-1375-400x225.avif)
![GAALFLEX® TRAY 600 CY Lean 4 GAALFLEX® TRAY 600 CY Lean: UV and Oil-Resistant Shielded Flexible Tray Machine-Tool Cable with Lean-Optimized Diameter for North American Industrial Cable-Tray Installations and EMI-Sensitive Machinery Environments (UL 600V / WTTC 1000V Nominal Voltage, 2 kV Test Voltage, Overall Tinned Copper Braid Screen with Aluminum Tape Wrap Providing 75+ dB EMI Suppression with Lean-Optimized Diameter Preventing Cable-Size Inflation, Comprehensive 3–25 Multi-Core Portfolio with 1–35 mm² Continuous Cross-Section Range Enabling Complete Machinery Cable Specification from Control Through Feeder Distribution with EMI Protection, Flexible 20×D Bending Radius Optimized for Cable-Tray Routing While Maintaining Shield Integrity, Lean-Diameter Design Enabling Tight Installation Spaces Without EMI Performance Compromise, UV-Resistant Special PVC Compound Enabling Outdoor and Equipment Mounting Areas Without Degradation, Oil-Resistant Black PVC Sheath Protecting Against Industrial Machinery Fluids, Radiation Hardening [8×10⁷ cJ/kg] Supporting 40-Year Industrial Infrastructure Design Life, AWM Style 2587 and TC-ER Type Certification Enabling Cable-Tray and Exposed-Run Applications, Numbered EN 50334 Core Identification Providing Permanent Electrical Conductor Coding, Class 5 Flexible Red Copper per IEC 60228, PVC/Nylon Compound Insulation, Aluminum Tape + Tinned Copper Braid Screen + Tinned Copper Drain Wire, FT4 / FT1 / FT2 Flame-Retardant Certification, Temperature Range −40 to +90°C Supporting Extreme Industrial Environments, Complete North American Industrial Compliance Enabling Machinery OEM Acceptance with Integrated EMI Suppression, RoHS and CE Certification, Engineered for Industrial Cable-Tray Installations with EMI Protection, Machine-Tool Environments, Outdoor Industrial Applications, Radiation-Hardened Infrastructure, and Applications Where Shielded EMI Suppression, Complete Multi-Core Standardization, Lean-Diameter Optimization, Flexible Tray-Cable Rating, Outdoor Durability, and Professional Industrial Equipment Compliance Are Mission-Critical Requirements)](https://feichuncables.com/blog/wp-content/uploads/image-1376-400x225.avif)