EN 50334 black numbered cores

GAALFLEX® CONTROL 601 CY (H05VVC4V5-K): Numbered-Core Shielded Flexible PVC Control Cable for EMI-Sensitive European and North American Building Electrical and Industrial Automation Applications (DIN VDE 300/500V Nominal Voltage [UL/CSA 600V Option Available], 3 kV Test Voltage, Overall Tinned Copper Braid Screen with Inner PVC Sheath Providing EMI Suppression and Coupling Prevention, Comprehensive 2–34 Multi-Core Portfolio with 0.5–2.5 mm² Continuous Cross-Section Range Enabling Complete EMI-Protected Control Specification, Flexible 12.5×D Bending Radius Optimized for Hand Routing and Equipment Mounting While Maintaining Shield Continuity, Self-Extinguishing and Flame-Retardant Performance per DIN VDE 0482 Part 265-2-1 / EN 50265-2-1 / IEC 60332-1-2 / DIN VDE 0482 Part 266-2 / EN 50266-2 / IEC 60332-3C Providing Professional Fire Safety, Class 5 Flexible Red Copper per IEC 60228, PVC Type TI1 Insulation per DIN VDE 0207 / UL 1581, PVC Type TM2 Inner Sheath, Grey (RAL 7001) Outer Sheath per DIN VDE 0281 Part 1 + HD 21.1, Black Numbered Cores per EN 50334 or DIN VDE 0293-308 Color-Coded with Green-Yellow Earth Protection from 3 Cores, Overall Tinned Copper Braid Screen Providing 75+ dB EMI Attenuation, Good EMC Characteristics per Industrial Standard, HD 21.13 S1 Flexible Standard Certification, Layered Stranding Architecture, UL VW-1 and CSA FT1 Flame-Retardant Certification, Temperature Range −40 to +70°C / −40 to +90°C Flexible Deployment (DIN VDE / UL/CSA), Complete Dual-Standard Compliance Enabling EMI-Sensitive European and North American Market Acceptance, RoHS and CE Certification, Engineered for EMI-Sensitive Building Electrical Distributions, Industrial Automation with Signal Integrity, Equipment Installation and Hand Routing, Flexible Shielded Control Circuits, and Applications Where Numbered-Core Shielded Standardization, Complete Multi-Core EMI Coverage, Inner Sheath Protection, Hand-Routing Flexibility, Self-Extinguishing Fire Safety, Good EMC Characteristics, and Dual-Standard Compliance Are Mission-Critical Requirements)

Type H05VVC4V5-K GAALFLEX® CONTROL 601 CY

GAALFLEX® CONTROL 601 CY (H05VVC4V5-K): Numbered-Core Shielded Flexible PVC Control Cable for EMI-Sensitive European and North American Building Electrical and Industrial Automation Applications (DIN VDE 300/500V Nominal Voltage [UL/CSA 600V Option Available], 3 kV Test Voltage, Overall Tinned Copper Braid Screen with Inner PVC Sheath Providing EMI Suppression and Coupling Prevention, Comprehensive 2–34 Multi-Core Portfolio with 0.5–2.5 mm² Continuous Cross-Section Range Enabling Complete EMI-Protected Control Specification, Flexible 12.5×D Bending Radius Optimized for Hand Routing and Equipment Mounting While Maintaining Shield Continuity, Self-Extinguishing and Flame-Retardant Performance per DIN VDE 0482 Part 265-2-1 / EN 50265-2-1 / IEC 60332-1-2 / DIN VDE 0482 Part 266-2 / EN 50266-2 / IEC 60332-3C Providing Professional Fire Safety, Class 5 Flexible Red Copper per IEC 60228, PVC Type TI1 Insulation per DIN VDE 0207 / UL 1581, PVC Type TM2 Inner Sheath, Grey (RAL 7001) Outer Sheath per DIN VDE 0281 Part 1 + HD 21.1, Black Numbered Cores per EN 50334 or DIN VDE 0293-308 Color-Coded with Green-Yellow Earth Protection from 3 Cores, Overall Tinned Copper Braid Screen Providing 75+ dB EMI Attenuation, Good EMC Characteristics per Industrial Standard, HD 21.13 S1 Flexible Standard Certification, Layered Stranding Architecture, UL VW-1 and CSA FT1 Flame-Retardant Certification, Temperature Range −40 to +70°C / −40 to +90°C Flexible Deployment (DIN VDE / UL/CSA), Complete Dual-Standard Compliance Enabling EMI-Sensitive European and North American Market Acceptance, RoHS and CE Certification, Engineered for EMI-Sensitive Building Electrical Distributions, Industrial Automation with Signal Integrity, Equipment Installation and Hand Routing, Flexible Shielded Control Circuits, and Applications Where Numbered-Core Shielded Standardization, Complete Multi-Core EMI Coverage, Inner Sheath Protection, Hand-Routing Flexibility, Self-Extinguishing Fire Safety, Good EMC Characteristics, and Dual-Standard Compliance Are Mission-Critical Requirements)
GAALFLEX® CONTROL 600 MTW: Type MTW Industrial Machinery Multi-Core Control Cable for North American Manufacturing Environments (UL 600V [CSA 1000V Option] Nominal Voltage, 4 kV Test Voltage, Comprehensive 3–50 Multi-Core Portfolio with 1–35 mm² Continuous Cross-Section Range Enabling Complete Machinery Control Specification Without Product Fragmentation, Cable-Tray-Rated Flexible Architecture Enabling Overhead Routing in Industrial Facilities and Manufacturing Floors, Impact and Crushing Resistance per UL 1277 Supporting Machinery Vibration Environments and Equipment Mechanical Stress, NFPA 79 Industrial Machinery Certification Enabling Direct Integration into Manufacturing Equipment OEM Systems, Small 4×D Fixed-Laying Bending Radius Enabling Tight Equipment Room and Machinery Routing, Special PVC/Nylon Compound Insulation Optimized for Industrial Durability and Oil Resistance, Grey (RAL 7001) Outer Sheath, Black EN 50334 Numbered Cores (2–5 Cores) or DIN VDE 0293-308 Color-Coded Cores (from 6 Cores) plus Green-Yellow Earth Protection (from 3 Cores), Layered Stranding Architecture Supporting Mechanical Flexibility and Durability, UL VW-1 and CSA FT1-FT2 Flame-Retardant Certification, Temperature Range −40 to +90°C Fixed Installation / −25 to +90°C Flexible Deployment Optimized for North American Climate Variations, Complete North American Industrial Compliance Enabling Machinery OEM Acceptance, UL AWM Style 2587/21216 Certification, RoHS and CE Certification, Engineered for North American Industrial Machinery Electrical Distribution, Cable-Tray Installations, Manufacturing Equipment Interconnection, Industrial Plant Control Systems, Heavy Equipment Operations, and Applications Where Type MTW Certification, Cable-Tray Rating, Complete Multi-Core Standardization, Impact and Crushing Durability, NFPA 79 Industrial Machinery Compliance, and Professional Industrial Machinery Reliability Are Mission-Critical Requirements)

GAALFLEX® CONTROL 600 MTW CY Lean

GAALFLEX® CONTROL 600 MTW: Type MTW Industrial Machinery Multi-Core Control Cable for North American Manufacturing Environments (UL 600V [CSA 1000V Option] Nominal Voltage, 4 kV Test Voltage, Comprehensive 3–50 Multi-Core Portfolio with 1–35 mm² Continuous Cross-Section Range Enabling Complete Machinery Control Specification Without Product Fragmentation, Cable-Tray-Rated Flexible Architecture Enabling Overhead Routing in Industrial Facilities and Manufacturing Floors, Impact and Crushing Resistance per UL 1277 Supporting Machinery Vibration Environments and Equipment Mechanical Stress, NFPA 79 Industrial Machinery Certification Enabling Direct Integration into Manufacturing Equipment OEM Systems, Small 4×D Fixed-Laying Bending Radius Enabling Tight Equipment Room and Machinery Routing, Special PVC/Nylon Compound Insulation Optimized for Industrial Durability and Oil Resistance, Grey (RAL 7001) Outer Sheath, Black EN 50334 Numbered Cores (2–5 Cores) or DIN VDE 0293-308 Color-Coded Cores (from 6 Cores) plus Green-Yellow Earth Protection (from 3 Cores), Layered Stranding Architecture Supporting Mechanical Flexibility and Durability, UL VW-1 and CSA FT1-FT2 Flame-Retardant Certification, Temperature Range −40 to +90°C Fixed Installation / −25 to +90°C Flexible Deployment Optimized for North American Climate Variations, Complete North American Industrial Compliance Enabling Machinery OEM Acceptance, UL AWM Style 2587/21216 Certification, RoHS and CE Certification, Engineered for North American Industrial Machinery Electrical Distribution, Cable-Tray Installations, Manufacturing Equipment Interconnection, Industrial Plant Control Systems, Heavy Equipment Operations, and Applications Where Type MTW Certification, Cable-Tray Rating, Complete Multi-Core Standardization, Impact and Crushing Durability, NFPA 79 Industrial Machinery Compliance, and Professional Industrial Machinery Reliability Are Mission-Critical Requirements)
GAALFLEX® CONTROL 600 MTW: Type MTW Industrial Machinery Multi-Core Control Cable for North American Manufacturing Environments (UL 600V [CSA 1000V Option] Nominal Voltage, 4 kV Test Voltage, Comprehensive 3–50 Multi-Core Portfolio with 1–35 mm² Continuous Cross-Section Range Enabling Complete Machinery Control Specification Without Product Fragmentation, Cable-Tray-Rated Flexible Architecture Enabling Overhead Routing in Industrial Facilities and Manufacturing Floors, Impact and Crushing Resistance per UL 1277 Supporting Machinery Vibration Environments and Equipment Mechanical Stress, NFPA 79 Industrial Machinery Certification Enabling Direct Integration into Manufacturing Equipment OEM Systems, Small 4×D Fixed-Laying Bending Radius Enabling Tight Equipment Room and Machinery Routing, Special PVC/Nylon Compound Insulation Optimized for Industrial Durability and Oil Resistance, Grey (RAL 7001) Outer Sheath, Black EN 50334 Numbered Cores (2–5 Cores) or DIN VDE 0293-308 Color-Coded Cores (from 6 Cores) plus Green-Yellow Earth Protection (from 3 Cores), Layered Stranding Architecture Supporting Mechanical Flexibility and Durability, UL VW-1 and CSA FT1-FT2 Flame-Retardant Certification, Temperature Range −40 to +90°C Fixed Installation / −25 to +90°C Flexible Deployment Optimized for North American Climate Variations, Complete North American Industrial Compliance Enabling Machinery OEM Acceptance, UL AWM Style 2587/21216 Certification, RoHS and CE Certification, Engineered for North American Industrial Machinery Electrical Distribution, Cable-Tray Installations, Manufacturing Equipment Interconnection, Industrial Plant Control Systems, Heavy Equipment Operations, and Applications Where Type MTW Certification, Cable-Tray Rating, Complete Multi-Core Standardization, Impact and Crushing Durability, NFPA 79 Industrial Machinery Compliance, and Professional Industrial Machinery Reliability Are Mission-Critical Requirements)

GAALFLEX® CONTROL 600 MTW

GAALFLEX® CONTROL 600 MTW: Type MTW Industrial Machinery Multi-Core Control Cable for North American Manufacturing Environments (UL 600V [CSA 1000V Option] Nominal Voltage, 4 kV Test Voltage, Comprehensive 3–50 Multi-Core Portfolio with 1–35 mm² Continuous Cross-Section Range Enabling Complete Machinery Control Specification Without Product Fragmentation, Cable-Tray-Rated Flexible Architecture Enabling Overhead Routing in Industrial Facilities and Manufacturing Floors, Impact and Crushing Resistance per UL 1277 Supporting Machinery Vibration Environments and Equipment Mechanical Stress, NFPA 79 Industrial Machinery Certification Enabling Direct Integration into Manufacturing Equipment OEM Systems, Small 4×D Fixed-Laying Bending Radius Enabling Tight Equipment Room and Machinery Routing, Special PVC/Nylon Compound Insulation Optimized for Industrial Durability and Oil Resistance, Grey (RAL 7001) Outer Sheath, Black EN 50334 Numbered Cores (2–5 Cores) or DIN VDE 0293-308 Color-Coded Cores (from 6 Cores) plus Green-Yellow Earth Protection (from 3 Cores), Layered Stranding Architecture Supporting Mechanical Flexibility and Durability, UL VW-1 and CSA FT1-FT2 Flame-Retardant Certification, Temperature Range −40 to +90°C Fixed Installation / −25 to +90°C Flexible Deployment Optimized for North American Climate Variations, Complete North American Industrial Compliance Enabling Machinery OEM Acceptance, UL AWM Style 2587/21216 Certification, RoHS and CE Certification, Engineered for North American Industrial Machinery Electrical Distribution, Cable-Tray Installations, Manufacturing Equipment Interconnection, Industrial Plant Control Systems, Heavy Equipment Operations, and Applications Where Type MTW Certification, Cable-Tray Rating, Complete Multi-Core Standardization, Impact and Crushing Durability, NFPA 79 Industrial Machinery Compliance, and Professional Industrial Machinery Reliability Are Mission-Critical Requirements)
GAALFLEX® CONTROL 600 PVC: UL/CSA Certified Multi-Core Control Cable for North American Industrial Applications with Comprehensive 2–50 Core Standardization and Complete 0.5–70 mm² Cross-Section Coverage (UL 1000V / CSA 1000V Nominal Voltage [600V Option Available], 3 kV Test Voltage per DIN VDE 0281 Part 2 + HD 21.2, Compact 4×D Fixed-Laying Bending Radius Enabling Tight Equipment Routing Through Industrial Enclosures and Control Panels, Comprehensive 2–50 Multi-Core Portfolio with 0.5–70 mm² Continuous Cross-Section Range Enabling Single-Product Specification Across All Industrial Control Applications, Flexible Class 5 Red Bare Copper per IEC 60228 and DIN VDE 0295, GAALTHERM® 521 Insulation and Grey (RAL 7001) GAALTHERM® 521 Outer Sheath Engineered for North American Industrial Environments, Oil-Resistant Chemistry per DIN EN 50290-2-22 / VDE 0819-102 TM54 Enabling Safe Deployment in Oil-Exposed Areas and Industrial Machine Environments, UL VW-1 and CSA FT1 Flame-Retardant Certification Providing Professional-Grade Fire Safety, Plus IEC 60332-1-2 and IEC 60332-3-24 Enhanced Flame Testing, Black EN 50334 Numbered Cores (2–5 Cores) or DIN VDE 0293-308 Color-Coded Cores (from 6 Cores) plus Green-Yellow Earth Protection (from 3 Cores) Enabling Standard Wiring Without Reference Documentation, Temperature Range −40 to +90°C Fixed Installation / −5 to +90°C Non-Continuously Flexible Deployment Optimized for Industrial Climate Variations, North American UL AWM Style Certification (21179 for 90°C/1000V or 105°C/1000V, or Style 2587 for 90°C/600V) Enabling Direct Acceptance in North American Equipment and Control Systems, RoHS and CE Certification, Engineered for North American Industrial Plant Electrical Distribution, Equipment Interconnection Systems, Industrial Automation Control Circuits, Heavy Manufacturing Facilities, Chemical Plant Installations, and Applications Where UL/CSA Certification, Comprehensive Multi-Core Standardization, Oil Resistance, and Professional Industrial Reliability Are Operational Requirements)

GAALFLEX® CONTROL 600

GAALFLEX® CONTROL 600 PVC: UL/CSA Certified Multi-Core Control Cable for North American Industrial Applications with Comprehensive 2–50 Core Standardization and Complete 0.5–70 mm² Cross-Section Coverage (UL 1000V / CSA 1000V Nominal Voltage [600V Option Available], 3 kV Test Voltage per DIN VDE 0281 Part 2 + HD 21.2, Compact 4×D Fixed-Laying Bending Radius Enabling Tight Equipment Routing Through Industrial Enclosures and Control Panels, Comprehensive 2–50 Multi-Core Portfolio with 0.5–70 mm² Continuous Cross-Section Range Enabling Single-Product Specification Across All Industrial Control Applications, Flexible Class 5 Red Bare Copper per IEC 60228 and DIN VDE 0295, GAALTHERM® 521 Insulation and Grey (RAL 7001) GAALTHERM® 521 Outer Sheath Engineered for North American Industrial Environments, Oil-Resistant Chemistry per DIN EN 50290-2-22 / VDE 0819-102 TM54 Enabling Safe Deployment in Oil-Exposed Areas and Industrial Machine Environments, UL VW-1 and CSA FT1 Flame-Retardant Certification Providing Professional-Grade Fire Safety, Plus IEC 60332-1-2 and IEC 60332-3-24 Enhanced Flame Testing, Black EN 50334 Numbered Cores (2–5 Cores) or DIN VDE 0293-308 Color-Coded Cores (from 6 Cores) plus Green-Yellow Earth Protection (from 3 Cores) Enabling Standard Wiring Without Reference Documentation, Temperature Range −40 to +90°C Fixed Installation / −5 to +90°C Non-Continuously Flexible Deployment Optimized for Industrial Climate Variations, North American UL AWM Style Certification (21179 for 90°C/1000V or 105°C/1000V, or Style 2587 for 90°C/600V) Enabling Direct Acceptance in North American Equipment and Control Systems, RoHS and CE Certification, Engineered for North American Industrial Plant Electrical Distribution, Equipment Interconnection Systems, Industrial Automation Control Circuits, Heavy Manufacturing Facilities, Chemical Plant Installations, and Applications Where UL/CSA Certification, Comprehensive Multi-Core Standardization, Oil Resistance, and Professional Industrial Reliability Are Operational Requirements)
GAALFLEX® CONTROL H05BQ-F PUR: Professional-Grade Hand-Held Power Tool Cable with Ultra-Flexible 4×D Architecture and Comprehensive Job-Site Durability (300/500V Nominal Voltage, 2 kV Test Voltage per DIN VDE 0281, Designed Specifically for Hand-Held Electric Tools Including Drills, Impact Drivers, Angle Grinders, Circular Saws, and Other Portable Equipment Requiring Continuous Rotation and Aggressive Flexing, Ultra-Flexible 4×D Bending Radius Enabling 360° Continuous Rotation Without Insulation Fatigue or Conductor Breakage, Class 5 Flexible Red Bare Copper per IEC 60228 and DIN VDE 0295, Rubber-Compound Insulation Optimized for Mechanical Durability and Electrical Safety, Orange (RAL 2003) PUR Outer Sheath Providing High-Visibility Tool Identification and Comprehensive Chemical, UV, and Abrasion Resistance, Abrasion Resistance Certification per HD 22.10.S1 and DIN VDE 0282 T10 Enabling Robust Job-Site Routing Through Rough Terrain, Construction Debris, and Pipe Clamp Integration Without Insulation Exposure, Suitable for Dry, Humid, and Wet Environments Enabling Deployment in Rainy Conditions and Damp Construction Sites, Outdoor Use Support Within Temperature Range (−40 to +90°C Both Fixed and Flexible) Enabling Year-Round Job-Site Operations, DIN VDE 0293-308 Color-Coded Cores (from 6 Cores) or EN 50334 Black Numbered Cores (2–5 Cores) Enabling Standard Wiring Without Reference Documentation, Green-Yellow Earth Protection Cores Available from 3-Core Configurations, Layered Stranding Architecture Optimizing Flexibility and Copper Density, Complete 2–7 Core Portfolio with 1 mm² Continuous Cross-Section Standardization Enabling Single Product Specification Across All Hand-Held Tool Applications, RoHS and CE Certified, Not Suitable for Underground Laying, Engineered for Construction Sites, Industrial Job Sites, Outdoor Temporary Installations, Professional Power Tool Operations, and Applications Where Continuous Rotation, Aggressive Flexing, Chemical Durability, and Comprehensive Job-Site Environmental Resistance Are Operational Requirements)

GAALFLEX® CONTROL H05BQ-F

GAALFLEX® CONTROL H05BQ-F PUR: Professional-Grade Hand-Held Power Tool Cable with Ultra-Flexible 4×D Architecture and Comprehensive Job-Site Durability (300/500V Nominal Voltage, 2 kV Test Voltage per DIN VDE 0281, Designed Specifically for Hand-Held Electric Tools Including Drills, Impact Drivers, Angle Grinders, Circular Saws, and Other Portable Equipment Requiring Continuous Rotation and Aggressive Flexing, Ultra-Flexible 4×D Bending Radius Enabling 360° Continuous Rotation Without Insulation Fatigue or Conductor Breakage, Class 5 Flexible Red Bare Copper per IEC 60228 and DIN VDE 0295, Rubber-Compound Insulation Optimized for Mechanical Durability and Electrical Safety, Orange (RAL 2003) PUR Outer Sheath Providing High-Visibility Tool Identification and Comprehensive Chemical, UV, and Abrasion Resistance, Abrasion Resistance Certification per HD 22.10.S1 and DIN VDE 0282 T10 Enabling Robust Job-Site Routing Through Rough Terrain, Construction Debris, and Pipe Clamp Integration Without Insulation Exposure, Suitable for Dry, Humid, and Wet Environments Enabling Deployment in Rainy Conditions and Damp Construction Sites, Outdoor Use Support Within Temperature Range (−40 to +90°C Both Fixed and Flexible) Enabling Year-Round Job-Site Operations, DIN VDE 0293-308 Color-Coded Cores (from 6 Cores) or EN 50334 Black Numbered Cores (2–5 Cores) Enabling Standard Wiring Without Reference Documentation, Green-Yellow Earth Protection Cores Available from 3-Core Configurations, Layered Stranding Architecture Optimizing Flexibility and Copper Density, Complete 2–7 Core Portfolio with 1 mm² Continuous Cross-Section Standardization Enabling Single Product Specification Across All Hand-Held Tool Applications, RoHS and CE Certified, Not Suitable for Underground Laying, Engineered for Construction Sites, Industrial Job Sites, Outdoor Temporary Installations, Professional Power Tool Operations, and Applications Where Continuous Rotation, Aggressive Flexing, Chemical Durability, and Comprehensive Job-Site Environmental Resistance Are Operational Requirements)