FLEXIFESTOON® (N)GRDGCGÖU-J
EMC Performance Classification: EMC rating scale (VDE/EN standards): Basic: No shielding (part 813 unscreened) Fair: Partial coverage, 30–40 mm spacing in braid Good: 80–90% coverage, 95% coverage, all gaps 30 dB attenuation @ 500 kHz: >40 dB attenuation @ 5 MHz: >35 dB attenuation (typical peak range) Expected: Tinned copper braid achieves 35–50 dB across frequency range Immunity to external interference: Motor variable frequency drive (VFD) nearby: VFD RF emission: Typically 50–200 mV/m at cable distance Unshielded cable susceptibility: 100–500 mV induced noise Shielded cable (good EMC): 1–10 mV induced noise (50–100× reduction) Consequence: VFD-driven crane motor doesn’t interfere with control signals No false triggering of safety systems Data integrity in digital control systems maintained Radiated immunity testing (per EN 61000-4-3): Test standard: Cable exposed to RF field 50 MHz–1 GHz Test field strength: 10 V/m typical Acceptance: No malfunction, signal corruption










![GAALFLEX® VFD 2XSLCHK-J 11 GAALFLEX® VFD 2XSLCHK-J: CPR-Compliant Oil-Resistant Halogen-Free Variable Frequency Drive Inverter Connection Cable for European Building and Industrial Applications with Oil-Exposure Environments, Higher-Temperature Industrial Systems, and Mining Operations (0.6/1 kV Nominal Voltage, 4 kV Test Voltage, CPR EU 305/2011 + EN 50575:2014+A1:2016 Compliance with Dca-S1b,d2,a1 Fire Classification [Enhanced Performance: Low Smoke, Zero Halogen, Minimal Toxicity, Limited Corrosive Gases], Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions Plus New 7-Core Option], 1.5–300 mm² Conductor Range Enabling Complete VFD Specification Across Industrial Applications, Flexible Class 5 Red Copper per IEC 60228, Special XLPE [Cross-Linked Polyethylene] Halogen-Free Insulation with Oil Resistance per IEC 60811-404, Low Corrosive Gas Emission per IEC 60754-2, Low Smoke Density per IEC 61034-1-2, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding, Low Mutual Capacitance [70–410 nF/km] Minimizing Cross-Talk, Low Coupling Resistance [Max 250 Ω/km] Supporting Low-Impedance Control, Black Halogen-Free PVC Outer Sheath with UV Resistance for Outdoor Industrial Deployment, Temperature Range −40 to +90°C [Fixed Laying] or −15 to +90°C [Flexible Application] with +90°C Conductor and +250°C Short-Circuit Capability Enabling High-Temperature Industrial Facilities, Mining Application Suitability per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 / DIN VDE 0875 / EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1 / EN 50265-2-1 / IEC 60332-1-2 / DIN VDE 0482 part 266-4-2 / EN 50266-4-2 / IEC 60332-3-24, Insulation Resistance 200+ MΩ·km, Radiation Resistance to 80×10⁶ cJ/kg, Oil-Resistant Construction Eliminating Cable Degradation in Petrochemical/Automotive/Food Processing Environments, Halogen-Free Zero-Halogen Construction Eliminating Toxic Chlorine/Fluorine Emissions During Fire, RoHS and CE Approved, and Complete European and International Compliance Enabling Building Code Acceptance and Professional VFD System Integration in High-Temperature Oil-Exposure Environments)](https://feichuncables.com/blog/wp-content/uploads/image-1387.avif)
![GAALFLEX® VFD 2XSLCYK 12 GAALFLEX® VFD 2XSLCYK: CPR-Compliant Halogen-Free Variable Frequency Drive Inverter Connection Cable for European Building Applications, Industrial Frequency Converter Systems, and Mining Operations (0.6/1 kV Nominal Voltage, 4 kV Test Voltage, CPR EU 305/2011 + EN 50575:2014+A1:2016 Compliance with Cca-s3,d1,a3 Fire Classification [Low Smoke, Zero Halogen, Minimal Toxicity], Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5–300 mm² Conductor Range Enabling Complete VFD Specification Across Industrial Applications, Flexible Class 5 Red Copper per IEC 60228, Special XLPE [Cross-Linked Polyethylene] Insulation Providing Halogen-Free Performance, Low Corrosive Gas Emission, and Superior Thermal Stability, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding, Low Mutual Capacitance [70–410 nF/km] Minimizing Cross-Talk, Low Coupling Resistance [Max 250 Ω/km] Supporting Low-Impedance Control, Black RAL 9005 PVC Outer Sheath with UV Resistance for Outdoor Industrial Deployment, Temperature Range −40 to +70°C [Fixed Laying] or −15 to +70°C [Flexible Application] with +90°C Conductor and +250°C Short-Circuit Capability, Mining Application Suitability per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 / DIN VDE 0875 / EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1 / EN 50265-2-1 / IEC 60332-1-2 / EN 50399, Insulation Resistance 200+ MΩ·km, Radiation Resistance to 80×10⁶ cJ/kg, Halogen-Free Zero-Halogen Construction Eliminating Toxic Chlorine/Fluorine Emissions During Fire, Suitable for Buildings, Plants, Fixed Installations, Medium Mechanical Stress, Forced-Movement Flexible Installations in Dry/Moist/Wet Environments, Automotive and Food Industry Applications, SIMOVERT Frequency Converter Integration, Industrial Pump/Ventilator/Conveyor/Air-Conditioning Systems, RoHS and CE Approved, and Complete European and International Compliance Enabling Building Code Acceptance and Professional VFD System Integration)](https://feichuncables.com/blog/wp-content/uploads/image-1386.avif)
![Type H05VVC4V5-K GAALFLEX® CONTROL 601 CY 13 GAALFLEX® CONTROL 601 CY (H05VVC4V5-K): Numbered-Core Shielded Flexible PVC Control Cable for EMI-Sensitive European and North American Building Electrical and Industrial Automation Applications (DIN VDE 300/500V Nominal Voltage [UL/CSA 600V Option Available], 3 kV Test Voltage, Overall Tinned Copper Braid Screen with Inner PVC Sheath Providing EMI Suppression and Coupling Prevention, Comprehensive 2–34 Multi-Core Portfolio with 0.5–2.5 mm² Continuous Cross-Section Range Enabling Complete EMI-Protected Control Specification, Flexible 12.5×D Bending Radius Optimized for Hand Routing and Equipment Mounting While Maintaining Shield Continuity, Self-Extinguishing and Flame-Retardant Performance per DIN VDE 0482 Part 265-2-1 / EN 50265-2-1 / IEC 60332-1-2 / DIN VDE 0482 Part 266-2 / EN 50266-2 / IEC 60332-3C Providing Professional Fire Safety, Class 5 Flexible Red Copper per IEC 60228, PVC Type TI1 Insulation per DIN VDE 0207 / UL 1581, PVC Type TM2 Inner Sheath, Grey (RAL 7001) Outer Sheath per DIN VDE 0281 Part 1 + HD 21.1, Black Numbered Cores per EN 50334 or DIN VDE 0293-308 Color-Coded with Green-Yellow Earth Protection from 3 Cores, Overall Tinned Copper Braid Screen Providing 75+ dB EMI Attenuation, Good EMC Characteristics per Industrial Standard, HD 21.13 S1 Flexible Standard Certification, Layered Stranding Architecture, UL VW-1 and CSA FT1 Flame-Retardant Certification, Temperature Range −40 to +70°C / −40 to +90°C Flexible Deployment (DIN VDE / UL/CSA), Complete Dual-Standard Compliance Enabling EMI-Sensitive European and North American Market Acceptance, RoHS and CE Certification, Engineered for EMI-Sensitive Building Electrical Distributions, Industrial Automation with Signal Integrity, Equipment Installation and Hand Routing, Flexible Shielded Control Circuits, and Applications Where Numbered-Core Shielded Standardization, Complete Multi-Core EMI Coverage, Inner Sheath Protection, Hand-Routing Flexibility, Self-Extinguishing Fire Safety, Good EMC Characteristics, and Dual-Standard Compliance Are Mission-Critical Requirements)](https://feichuncables.com/blog/wp-content/uploads/image-1373.avif)
![Type H05VV5-F GAALFLEX® CONTROL 601 14 GAALFLEX® CONTROL 601 (H05VV5-F): Numbered-Core Flexible PVC Control Cable for European and North American Building Electrical and Industrial Control Applications (DIN VDE 300/500V Nominal Voltage [UL/CSA 600V Option Available], 3 kV Test Voltage, Comprehensive 2–61 Multi-Core Portfolio with 0.5–2.5 mm² Continuous Cross-Section Range Enabling Complete Control Specification from Communication Circuits Through Distribution Systems, Small H05-Series Diameter Optimized for Compact Routing in Tight Installation Spaces and Cable Tray Applications, Flexible 12.5×D Bending Radius Optimized for Hand Routing and Equipment Mounting Without Cable Stress, Self-Extinguishing and Flame-Retardant Performance per DIN VDE 0482 Part 265-2-1 / EN 50265-2-1 / IEC 60332-1-2 / DIN VDE 0482 Part 266-2 / EN 50266-2 / IEC 60332-3C Providing Professional Fire Safety, Class 5 Flexible Red Copper per IEC 60228, PVC Type TI1 Insulation per DIN VDE 0207 / UL 1581, Grey (RAL 7001) Outer Sheath per DIN VDE 0281 Part 1 + HD 21.1, Black Numbered Cores per EN 50334 (2–5 Cores) or DIN VDE 0293-308 Color-Coded (from 6 Cores) with Green-Yellow Earth Protection (from 3 Cores), HD 21.13 S1 Flexible Standard Certification Enabling Hand Routing and Equipment Installation, Layered Stranding Architecture Supporting Mechanical Flexibility and Durability, UL VW-1 and CSA FT1 Flame-Retardant Certification, Temperature Range −40 to +70°C Fixed Installation / −5 to +70°C Flexible Deployment (DIN VDE Standard), Extended −40 to +90°C Fixed Installation (UL/CSA Option), Complete Dual-Standard Compliance Enabling European and North American Market Acceptance, RoHS and CE Certification, Engineered for Building Electrical Distributions, Industrial Control Systems, Equipment Installation, Flexible Equipment Routing, and Applications Where Numbered-Core Standardization, Complete Multi-Core Coverage, Small H05-Series Diameter, Flexible Hand Routing, Self-Extinguishing Fire Safety, and Dual-Standard Compliance Are Mission-Critical Requirements)](https://feichuncables.com/blog/wp-content/uploads/image-1372.avif)