TROMMELFLEX-PUR — Complete Halogen-Free PUR Reeling Cable Series

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
TROMMELFLEX-PUR — Complete Halogen-Free PUR Reeling Cable Engineering Guide
TROMMELFLEX PUR-HFD12Y11YU11YTROMMELFLEX-M-PURD2X11YBRAIDED0.6/1 kV

TROMMELFLEX-PUR — Complete Halogen-Free PUR Reeling Cable Series

A professional engineering guide to the black industrial PUR-HF reeling family and the yellow underground-mining M-PUR designs, including 56 current specification records, detailed construction diagrams, the aramid-reinforced braided branch, legacy Part-number mapping, water duty, calculations and failure analysis.

30 PUR-HF rows12 M-PUR rows14 braided rows56 current records9 legacy Part numbers5 engineering diagrams
Rated voltage
0.6/1 kV
Highest tensile rule
25 N/mm²
Highest reference speed
180 m/min+
PUR-HF; consult above
Maximum published water depth
50 m
PUR-HF only

Contents

  1. Source hierarchy
  2. Applications
  3. PUR-HF cross-section
  4. M-PUR braided cross-section
  5. Family comparison
  6. Electrical and thermal limits
  7. PUR-HF 30-row matrix
  8. M-PUR 12-row matrix
  9. Braided 14-row matrix
  10. Revision comparison
  11. Braided dimensional effect
  12. Calculations
  13. Audit
  14. Selection
  15. Installation
  16. FMEA

1. Source hierarchy and counting rule

Current PUR-HF brochure
Current construction, performance limits, Part numbers and the complete 30-row matrix.
Current mining/tunnelling brochure
Current 12-row M-PUR matrix and 14-row braided matrix, including aramid reinforcement.
Legacy M-PUR product sheet
Nine historical Part numbers and the earlier current-carrying values for revision comparison.
Derived data
Short-circuit current for current M-PUR rows is calculated by main conductor section and marked in blue.
Counting rule: the article contains 56 current published specification records. The nine legacy M-PUR Part numbers identify constructions already present in the current matrix and are therefore not counted as additional rows.

2. Application architecture

TROMMELFLEX-PUR application architecture Crane and industrial reeling TROMMELFLEX PUR-HF Drills, scoops and LHDs TROMMELFLEX-M-PUR Higher-tension braided duty Aramid carrier + reinforcement braid

3. TROMMELFLEX PUR-HF detailed construction

TROMMELFLEX PUR-HF D12Y11YU11Y — detailed reeling-cable cross-section Representative four-core design; relative wall thicknesses are engineering illustration only. 1. Black polyurethane outer sheath Halogen-free, flame-retardant and opaque. 2. Open support braid Torsion-protection and load-distribution layer. 3. Halogen-free PUR inner sheath 4. Polyester-based insulation Halogen-free compound around each flexible core. 5. Plain copper, class 5 6. Central textile carrier Supports short-length-of-lay core geometry under repeated reeling. Published operating envelope 25 N/mm² conductor load · ±50°/m torsion · 6D moving radius · fully flexible −40…+80°C · permanent non-potable water duty to 50 m.
Construction principle: plain class-5 copper cores with polyester-based halogen-free insulation are laid around a central textile carrier. Halogen-free PUR inner and outer sheaths are separated by an open support braid.

4. TROMMELFLEX-M-PUR BRAIDED detailed construction

TROMMELFLEX-M-PUR BRAIDED D2X11Y — underground reeling cross-section Representative 3C + split-earth + control-core design with central aramid carrier. 1. Yellow PUR outer sheath Halogen-free, flame-retardant and abrasion-resistant. 2. Reinforcement braid Raises the permanent tensile rule from 20 to 25 N/mm². 3. Halogen-free polymer inner sheath 4. XLPE phase insulation 5. Bare class-5 copper 6. Split protective-earth sections 7. Control cores in the interstices 8. Central aramid carrier Supports cyclic reel loading and the higher tensile envelope. Published operating envelope 25 N/mm² · ±50°/m · 8D reeling radius · 100 m/min underground reeling · fully flexible −30…+80°C · maximum water depth 10 m.
Construction principle: three XLPE-insulated phase conductors, split protective-earth sections and optional control cores are laid around a central aramid carrier. A reinforcement braid raises the tensile and speed envelope relative to unbraided M-PUR.

5. The three constructions must remain separate

Three PUR constructions — limits are not interchangeable PUR-HF Black PUR inner and outer sheath Polyester-based insulation 25 N/mm² · 6D · ±50°/m 180 m/min reference 50 m permanent water duty 30 specification rows M-PUR unbraided Yellow PUR outer sheath XLPE insulation 20 N/mm² · 8D · ±50°/m 60 m/min underground reeling 10 m water depth 12 current rows M-PUR BRAIDED Central aramid carrier Reinforcement braid 25 N/mm² · 8D · ±50°/m 100 m/min underground reeling 10 m water depth 14 current rows
FamilyDesignationApplicationConstructionTensileTorsionRadiusSpeedWaterFlexible temperature
TROMMELFLEX PUR-HFD12Y11YU11Y-J/OCrane, hoist, reel, festoon and material handlingPolyester insulation; PUR inner/outer; textile carrier25 N/mm²±50°/m6D180 m/min; consult above50 m−40…+80°C
TROMMELFLEX-M-PURD2X11YUnderground drills, scoops and LHDsXLPE; halogen-free inner polymer; yellow PUR outer20 N/mm²±50°/m8D reeling60 m/min10 m−30…+80°C
TROMMELFLEX-M-PUR BRAIDEDD2X11YHigher-tension underground reel dutyXLPE; aramid carrier; reinforcement braid; yellow PUR25 N/mm²±50°/m8D reeling100 m/min10 m−30…+80°C

6. Electrical, thermal, fire and environmental framework

Rated voltage
0.6/1 kV; maximum AC 0.7/1.2 kV; maximum DC 0.9/1.8 kV.
Test voltage
2.5 kV AC for main cores, five minutes; M-PUR control cores 2 kV.
Thermal
90°C conductor and 250°C short-circuit conductor temperature.
Fire
Halogen-free construction and flame performance referenced to IEC 60332-1 / IEC 60332-1-2.
PUR-HF cold duty
Fixed −50…+80°C; fully flexible −40…+80°C.
M-PUR cold duty
Fixed −40…+80°C; fully flexible −30…+80°C.
Water boundary: PUR-HF is published for permanent non-potable water use to 50 m. M-PUR and M-PUR BRAIDED are published to 10 m. The gland, coupler, connector, splice and water chemistry require separate system qualification.

7. Complete TROMMELFLEX PUR-HF matrix — 30 rows

TROMMELFLEX PUR-HF · Control cables, 1.5 mm² · 5 rows
ConstructionCurrent Part no.Conductor ØDminDmaxR movingkg/kmFmax NR20 Ω/kmAIsc kAStatus
7×1.5202989101.51213.279232613.3230.21current official matrix
12×1.5202241591.515.516.71364513.3230.21current official matrix
18×1.5201654991.516.918.1109476713.3230.21current official matrix
24×1.5201945161.51920.21216913.3230.21current official matrix
30×1.5203005611.521.122.51357511213.3230.21current official matrix
TROMMELFLEX PUR-HF · Control cables, 2.5 mm² · 6 rows
ConstructionCurrent Part no.Conductor ØDminDmaxR movingkg/kmFmax NR20 Ω/kmAIsc kAStatus
7×2.520290595213.514.78831437.9830.36current official matrix
12×2.520181296218.920.112155757.9830.36current official matrix
18×2.520267171219.220.4122671127.9830.36current official matrix
24×2.520160534221.522.913787157.9830.36current official matrix
30×2.520197804224.4261561091877.9830.36current official matrix
36×2.520140743227.4291741412257.9830.36current official matrix
TROMMELFLEX PUR-HF · Four-core power cables · 8 rows
ConstructionCurrent Part no.Conductor ØDminDmaxR movingkg/kmFmax NR20 Ω/kmAIsc kAStatus
4×1.5not published1.51011.267151513.3230.21current official matrix
4×2.520290594211.112.2742257.9830.36current official matrix
4×4202241602.512.313.5812844.95410.57current official matrix
4×6201615033.114.115.2923763.3530.86current official matrix
4×10202816554.117.418.6112611.91741.43current official matrix
4×16202179225.12021.412885161.21992.29current official matrix
4×25201493786.223.524.9149123250.78391313.58current official matrix
4×35201567157.828.530.2181176350.5541625.01current official matrix
TROMMELFLEX PUR-HF · Five-core power cables · 8 rows
ConstructionCurrent Part no.Conductor ØDminDmaxR movingkg/kmFmax NR20 Ω/kmAIsc kAStatus
5×1.5202258721.510.611.771171813.3230.21current official matrix
5×2.520300565211.8137823317.9830.36current official matrix
5×4203005622.513.314.5873354.95410.57current official matrix
5×6202592533.116.417.610648753.3530.86current official matrix
5×10202157794.118.719.9119721251.91741.43current official matrix
5×16203005635.121.72313910321.21992.29current official matrix
5×25not published6.228.229.8179153120.78391313.58current official matrix
5×35not published7.831331982144370.5541625.01current official matrix
TROMMELFLEX PUR-HF · Combined power and screened control elements · 3 rows
ConstructionCurrent Part no.Conductor ØDminDmaxR movingkg/kmFmax NR20 Ω/kmAIsc kAStatus
4×6+4x(2×1.5)C202280083.123.124.51478763.3530.86current official matrix
4×16+2x(4×1.5)C201711515.124.726.3158114161.21992.29current official matrix
4×35+2x(4×1.5)C201737477.531.533.5201195350.5541625.01current official matrix

8. Current TROMMELFLEX-M-PUR matrix — 12 rows

The current brochure does not print Part numbers. Nine official identifiers from the previous product sheet are therefore retained in separate “Legacy Part no.” columns rather than presented as current order codes.

TROMMELFLEX-M-PUR · Three-phase power with split PE and controls · 9 rows
ConstructionCurrent Part no.Legacy Part no.Legacy AConductor ØDminDmaxR movingkg/kmFmax NR20 Ω/kmAIsc kAStatus
3×25+3G6+2×1not published203355311216.222.524192113150.781313.58current 2025 matrix; Isc derived
3×35+3G6+2×1.5not published203355321507.826.528224153210.5541625.01current 2025 matrix; Isc derived
3×50+3G10+2×1.5not published203338851839.6303225621630.3862027.15current 2025 matrix; Isc derived
3×70+3G16+2×1.5not published2033553323411.13537296305420.2722510.01current 2025 matrix; Isc derived
3×95+3G16+2×1.5not published2033553428412.639.542336369570.20630213.59current 2025 matrix; Isc derived
3×120+3G25+2×1.5not published2033553533014.84446.5372481720.16135217.16current 2025 matrix; Isc derived
3×150+3G25+2×1.5not published2033553638016495241657890.12940421.45current 2025 matrix; Isc derived
3×185+3G35+2×1.5not published2033553743417.753.556448731110.10646126.46current 2025 matrix; Isc derived
3×240+3G50+2×1.5not published2033553851220.261.564.5516961440.08015434.32current 2025 matrix; Isc derived
TROMMELFLEX-M-PUR · Four-core power · 2 rows
ConstructionCurrent Part no.Legacy Part no.Legacy AConductor ØDminDmaxR movingkg/kmFmax NR20 Ω/kmAIsc kAStatus
4×50not published9.633352824540.3862027.15current 2025 matrix; Isc derived
4×70not published11.138.140.632533560.2722510.01current 2025 matrix; Isc derived
TROMMELFLEX-M-PUR · Composite power and control · 1 rows
ConstructionCurrent Part no.Legacy Part no.Legacy AConductor ØDminDmaxR movingkg/kmFmax NR20 Ω/kmAIsc kAStatus
4G70+2x(10×2.5)+1x(8×1.5)Cnot published11.1626652853560.2722510.01current 2025 matrix; Isc derived

9. Current TROMMELFLEX-M-PUR BRAIDED matrix — 14 rows

TROMMELFLEX-M-PUR BRAIDED · Three-phase power without control cores · 4 rows
ConstructionCurrent Part no.Conductor ØDminDmaxR movingkg/kmFmax NR20 Ω/kmAIsc kAStatus
3×25+3G6not published6.223252121518750.781313.58current 2025 matrix; Isc derived
3×50+3G10not published9.630.532.5262253750.3862027.15current 2025 matrix; Isc derived
3×70+3G16not published11.135.537.533215250.2722510.01current 2025 matrix; Isc derived
3×95+3G16not published12.639.542.534392571250.20630113.59current 2025 matrix; Isc derived
TROMMELFLEX-M-PUR BRAIDED · Three-phase power with split PE and controls · 9 rows
ConstructionCurrent Part no.Conductor ØDminDmaxR movingkg/kmFmax NR20 Ω/kmAIsc kAStatus
3×25+3G6+2×1not published6.22324.5196124318750.781313.58current 2025 matrix; Isc derived
3×35+3G6+2×1.5not published7.826.528224157210.5541625.01current 2025 matrix; Isc derived
3×50+3G10+2×1.5not published9.630.532.52623763750.3862027.15current 2025 matrix; Isc derived
3×70+3G16+2×1.5not published11.135.537.5333555250.2722510.01current 2025 matrix; Isc derived
3×95+3G16+2×1.5not published12.64042.534405971250.20630113.59current 2025 matrix; Isc derived
3×120+3G25+2×1.5not published14.844.547376529190.16135217.16current 2025 matrix; Isc derived
3×150+3G25+2×1.5not published1649.552.542635811250.12940421.45current 2025 matrix; Isc derived
3×185+3G35+2×1.5not published17.75456.5452803138750.10646126.46current 2025 matrix; Isc derived
3×240+3G50+2×1.5not published20.26265521056180.08015434.32current 2025 matrix; Isc derived
TROMMELFLEX-M-PUR BRAIDED · Four-core power · 1 rows
ConstructionCurrent Part no.Conductor ØDminDmaxR movingkg/kmFmax NR20 Ω/kmAIsc kAStatus
4×16not published5.12223.51889161.21992.29current 2025 matrix; Isc derived

10. M-PUR current-carrying-capacity revision

ConstructionLegacy Part no.Legacy ACurrent AIncrease
3×25+3G6+2×12033553112113110
3×35+3G6+2×1.52033553215016212
3×50+3G10+2×1.52033388518320219
3×70+3G16+2×1.52033553323425016
3×95+3G16+2×1.52033553428430218
3×120+3G25+2×1.52033553533035222
3×150+3G25+2×1.52033553638040424
3×185+3G35+2×1.52033553743446127
3×240+3G50+2×1.52033553851254028
Revision control: current ampacity values are used for current preliminary selection. The legacy values remain relevant when evaluating an older supplied Part number or archived project documentation.

11. Dimensional and tensile effect of the braided design

ConstructionDmax unbraidedDmax braidedΔDkg/km unbraidedkg/km braidedΔ massF unbraidedF braidedΔF
3×25+3G6+2×12424.50.51131243113151875375
3×35+3G6+2×1.52828015315742121
3×50+3G10+2×1.53232.50.52162376216337575
3×70+3G16+2×1.53737.50.5305335530542525105
3×95+3G16+2×1.54242.50.536940593695771251425
3×120+3G25+2×1.546.5470.5481529148172918
3×150+3G25+2×1.55252.50.5578635857891125225
3×185+3G35+2×1.55656.50.57380373111138752775
3×240+3G50+2×1.564.5650.5961056961441836
The braid and central aramid carrier generally add mass and increase Fmax from the 20 N/mm² rule to the 25 N/mm² rule. The exact diameter change is construction-specific.

12. Representative engineering calculations

Three-phase apparent power at 1 kV: S = √3 × U × IActive power at cosφ 0.9: P = S × 0.9Resistive voltage drop for 100 m: ΔU = √3 × I × R20 × 0.1 kmWeight of 100 m: W = mass × 0.1 × gMinimum free loop diameter: approximately 2 × published moving radiusThe calculations do not replace motor-starting, VFD reflected-wave, thermal grouping, reel torque or dynamic acceleration analysis.
FamilyConstructionAkVAkW @0.9ΔU/100mWeight 100mLoop diameterFmax
PUR-HF4×35162280.6252.51.55%1.73 kN362 mm35 N
PUR-HF combined4×35+2x(4×1.5)C162280.6252.51.55%1.91 kN402 mm35 N
M-PUR3×95+3G16+2×1.5302523.1470.81.08%3.62 kN672 mm57 N
M-PUR composite4G70+2x(10×2.5)+1x(8×1.5)C250433389.71.18%5.2 kN1056 mm56 N
M-PUR BRAIDED3×95+3G16+2×1.5301521.3469.21.07%3.98 kN68 mm7125 N

13. Source anomaly and inference audit

ItemFieldPublished statusTreatmentReason
PUR-HF 4×1.5, 5×25 and 5×35Part numberBlank in current official matrixKept blankThe source states that rows without a Part number are approximate and must be confirmed at order.
M-PUR first nine power rowsPart numberCurrent 2025 matrix omits Part numbersLegacy official Part numbers retained separatelyThe older official product sheet published identifiers 20335531–20335538 plus 20333885.
M-PUR current capacityAmpacity2025 values exceed the older 2022 sheetBoth generations displayedCurrent values are used for the current matrix; legacy values are preserved only for revision comparison.
M-PUR short-circuit currentIscNot tabulated in the 2025 matrixDerived by conductor sectionValues follow the same conductor-section short-circuit values published elsewhere in the official series.
M-PUR 3×25 resistanceR200.78 Ω/km current; 0.7839 Ω/km legacyCurrent rounded value retainedNo silent replacement; the revision difference is explained.
M-PUR composite 4G70 + controlsFmax5,600 NApplied to main 4G70 power copperThe table does not add the control copper to the tensile-force rule.
Water depthPermanent immersionPUR-HF 50 m; M-PUR 10 mStrictly separatedThe two families use different construction and application limits.

14. Engineering selection workflow

TROMMELFLEX-PUR engineering selection workflow 1. Applicationcrane / mine / tunnel 2. Circuitpower / control / pairs 3. MechanicsF · R · speed · torsion 4. Environmentwater · fire · cold • Choose PUR-HF for industrial reels and severe bending; choose M-PUR for underground reeling. • Select the braided branch when the 25 N/mm² and 100 m/min envelope is required. • Verify current Dmin/Dmax, mass, radius, current and Part number for the exact construction. • Qualify the complete water system: cable, gland, coupler, repair joint and water chemistry. • Do not combine PUR-HF 50 m water duty with M-PUR, or apply braided limits to the unbraided cable.

15. Installation and acceptance checklist

  • Confirm the exact family: PUR-HF, M-PUR or M-PUR BRAIDED.
  • Verify the current construction, Part number status, Dmin/Dmax, radius, mass, Fmax, R20 and ampacity.
  • For underground reels, define reel torque, acceleration, guide pressure, trailing abrasion and cable payout geometry.
  • Use the braided design only where the central aramid carrier and reinforcement termination are mechanically supported.
  • Do not apply PUR-HF 50 m water duty to M-PUR; qualify the complete accessory system for immersion.
  • Check PE continuity and every control circuit before commissioning.
  • For combined control elements, confirm screening, pair assignment, protocol requirements and termination.
  • Record conductor resistance, agreed insulation test and baseline mechanical/visual condition.

16. Failure mode and effects analysis

Wrong PUR family: industrial PUR-HF limits are applied to an underground M-PUR construction.
Water-depth transfer: the 50 m PUR-HF claim is applied to a 10 m M-PUR cable or unqualified connector.
Unbraided over-speed: the 100 m/min braided limit is used for the 60 m/min unbraided design.
Carrier bypass: the braided aramid carrier is not anchored in the termination.
Control-element overload: the main-power tensile rule is incorrectly applied to small control conductors.
Revision mixing: legacy Part numbers are combined with current ampacity without project-specific verification.

17. Source map and scope

DocumentRoleScope
Official TROMMELFLEX / FESTOONFLEX PUR-HF brochure, current issuePUR-HF construction and matrix30 current rows, Part numbers, 25 N/mm², 6D, ±50°/m, 180 m/min reference and 50 m water duty.
Official Mining & Tunnelling brochure, 2025Current M-PUR families12 unbraided and 14 braided rows, 20/25 N/mm², 60/100 m/min, 8D and 10 m water depth.
Official four-page M-PUR product sheet, version 5Legacy identifiersNine legacy Part numbers and earlier ampacity values.
Crane Cables General Catalogue, product revision 2019Cross-checkPUR-HF construction, electrical parameters and historical matrix presentation.
This guide supports preliminary engineering and technical comparison. Current availability, certificates, compounds, Part numbers and guaranteed operating limits must be confirmed for the exact production batch.

Feichun Cable — TROMMELFLEX-PUR engineering support

Feichun Cable is not affiliated with the owners of the TROMMELFLEX, PUR-HF, D12Y11YU11Y or D2X11Y designations. Diagrams are independent engineering reconstructions, not manufacturing drawings. Source, legacy and derived data are explicitly separated.

FEICHUN-TROMMELFLEX-PUR-HQ-FULL-SERIES-EN · 03/08/2026
Previous Article

PROTOMONT (M) — Complete Flexible and Submersible Mining Cable Series

Next Article

SPREADERFLEX — Complete Basket, Vertical Reeling and Mobile Harbour Crane Series

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注