OZOFLEX PLUS and High-Flexibility Cables — Complete Series

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
OZOFLEX PLUS and High-Flexibility Cables — Complete Engineering Guide
OZOFLEX H07RN-FOZOFLEX(PLUS)H07RN8-FS07HXHXS07RN8H2-FOZOFLEX(FC+)

OZOFLEX PLUS and High-Flexibility Cables — Complete Series

A comprehensive English engineering guide covering heavy-duty high-flexibility H07RN-F cables, round and flat wastewater constructions, halogen-free variants and overall-screened FC+ cables for converter-fed pumps.

70 H07RN-F rows69 H07RN8-F rows9 flat rows12 FC+ rows160 records5 engineering diagrams
Voltage family
450/750 V
Maximum PLUS depth
2,000 m
H07RN8-F current overview
Water temperature
40°C
Conductor tensile load
15 N/mm²
PLUS and FC+ wastewater families

Contents

  1. Scope and source hierarchy
  2. Applications
  3. Family map
  4. Classic H07RN-F anatomy
  5. H07RN8-F anatomy
  6. FC+ anatomy
  7. Electrical and water limits
  8. H07RN-F matrix
  9. H07RN8-F matrix
  10. Flat matrix
  11. FC+ matrix
  12. Document conflicts
  13. Dimensional comparison
  14. Calculations
  15. Audit
  16. Selection
  17. Installation
  18. FMEA

1. Scope and source hierarchy

Classic high flexibility
A 70-row legacy engineering matrix for OZOFLEX H07RN-F, with material codes, current ratings and bending radii.
Round wastewater PLUS
A complete 69-row H07RN8-F engineering matrix with Part/MLFB, dimensions, tensile force and air/water current ratings.
Flat wastewater PLUS
Nine published S07RN8H2-F dimensions and weights.
Screened FC+
Twelve published S07RC4N8-F dimensions, mass and bending-radius records.
Commercial status: legacy material codes and Part numbers are search and traceability references. Current availability and orderability must be confirmed.

2. Application architecture

OZOFLEX application architecture Construction & industry H07RN-F heavy-duty flexibility Submersible pump H07RN8-F / flat S07RN8H2-F Wastewater tank Inspection and chemistry matter Converter-fed drive OZOFLEX FC+ overall screen

3. Family map

BrandDesignationShape/screenPrimary dutyCurrent depth positionWater/thermal pointMatrix status
OZOFLEXH07RN-FRound, unscreenedHeavy-duty flexible industrial cableNo product-level permanent wastewater depthRegional documents differLegacy 70-row engineering matrix
OZOFLEX(PLUS)H07RN8-FRound, unscreenedWastewater and submersible pump duty2,000 m40°C water50-row engineering matrix
OZOFLEX(PLUS)S07HXHXRound, halogen-freeLow-smoke/zero-halogen wastewater duty500 m in 2025 overview; 2,000 m in older detailed catalogue40°C waterNo complete public matrix
OZOFLEX(PLUS)S07RN8H2-FFlat, unscreenedFlat submersible pump lead500 m in 2025 overview; 2,000 m in older detailed catalogue40°C water9-row matrix
OZOFLEX(FC+)S07RC4N8-FRound, overall screenVFD-fed wastewater pumps and EMC500 m40°C water12-row matrix
OZOFLEX(FC+)S07HXCHX-FRound, screened, halogen-freeVFD wastewater duty with low-smoke/zero-halogen requirements500 m40°C waterNo complete public matrix

4. OZOFLEX H07RN-F detailed construction

OZOFLEX H07RN-F — heavy-duty high-flexibility rubber cable Representative multicore construction; single-core and thin-jacket variants may omit the common inner sheath. 1. Black EM2 rubber outer sheath Weather-, oil-, ozone- and impact-resistant elastomer. 2. Grey EM2/EM3 inner sheath Applied to control cables and thicker multicore jackets. 3. EI4 cross-linked elastomer insulation 4. Bare class-5 copper 5. Green/yellow protective conductor Document-generation caution A 2018 German brochure gives 90°C/250°C, while a separate Nordic product sheet gives 60°C/200°C. Use the exact regional and contractual datasheet.

5. OZOFLEX(PLUS) H07RN8-F detailed construction

OZOFLEX(PLUS) H07RN8-F — round wastewater cable Current-catalogue layer description; the 2016 engineering matrix used a CPE/EM7 outer-sheath description. 1. Black waterproof elastomer outer sheath Current catalogue: EPDM; 2016 matrix description: CPE EM7. 2. Water-resistant EPDM inner sheath Applied where required; reduces formation of water bubbles. 3. EPR insulation 4. Fine-stranded class-5 copper Tinned up to and including 6 mm² in the catalogue description. 5. Protective conductor where specified Water-duty boundary H07RN8-F remains listed at 2,000 m in the 2025 overview; aggressive or unusual water chemistry still requires individual compatibility review.

6. OZOFLEX(FC+) detailed screened construction

OZOFLEX(FC+) S07RC4N8-F — screened wastewater VFD cable Overall-screened construction for converter-fed AC drives; both ends require low-impedance screen bonding. 1. Black CPE outer sheath 2. Tinned-copper overall braid The shield must be bonded at both ends for effective EMC. 3. Water-resistant EPDM inner sheath 4. EPR core insulation 5. Fine-stranded class-5 copper Mechanical and water limits 500 m maximum submersion · 15 N/mm² conductor load · 4D fixed radius · 6D flexible radius · 40°C maximum water temperature.
Screen fault path: the overall braid is not only an EMC component. Its bonding, fault-current capability and termination geometry form part of the electrical protection design.

7. Electrical, mechanical and water framework

PLUS/FC+ voltage
Rated 0.45/0.75 kV; maximum AC 0.476/0.825 kV; maximum DC 0.619/1.238 kV.
PLUS/FC+ test
2.5 kV AC for 15 minutes; motor test 3 kV for no more than three minutes where specified.
PLUS thermal
90°C conductor, 250°C short circuit and 40°C maximum water temperature.
PLUS bending
3D fixed and 4D flexible for unscreened wastewater designs.
FC+ bending
4D fixed and 6D flexible.
Water chemistry
Process, cooling, mine-surface, rain, combined wastewater, groundwater and seawater are referenced, subject to composition review.

8. OZOFLEX H07RN-F legacy engineering matrix — 70 rows

This matrix is retained as a technical engineering reference. Current regional commercial sheets may publish a smaller product list and different thermal limits.

OZOFLEX H07RN-F · Single-core without PE · 15 rows
ConstructionLegacy material codeConductor ØODkg/kmA in airA on surfaceR fixedR movingRfixed/DRmoving/D
1×2.55DH2 10551.96.574322620203,08D3,08D
1×45DH2 10652.57.5101423423233,07D3,07D
1×65DH2 10753.28.3129544425333,01D3,98D
1×105DH2 11054.110202736130403D4D
1×165DH2 11255.612279988236483D4D
1×255DH2 11356.813.540712910854684D5,04D
1×355DH2 11458.115.554015813562784D5,03D
1×505DH2 11559.61874019816872904D5D
1×705DH2 116511.219.598024520878984D5,03D
1×955DH2 117513.222.51260292250901134D5,02D
1×1205DH2 118514.924.51560344292981234D5,02D
1×1505DH2 120516.62719203913351081354D5D
1×1855DH2 12151829.523004483821181484D5,02D
1×2405DH2 122521.23329605284531321654D5D
1×3005DH2 123523.63636106085231441804D5D
OZOFLEX H07RN-F · Two-core without PE · 4 rows
ConstructionLegacy material codeConductor ØODkg/kmA in airA on surfaceR fixedR movingRfixed/DRmoving/D
2×15DH2 20351.28.3102161525333,01D3,98D
2×1.55DH2 20451.59.2128191828373,04D4,02D
2×2.55DH2 20551.911190272633443D4D
2×45DH2 20652.512.5263363450634D5,04D
OZOFLEX H07RN-F · Three-core without PE · 13 rows
ConstructionLegacy material codeConductor ØODkg/kmA in airA on surfaceR fixedR movingRfixed/DRmoving/D
3×1.55DH2 85541.510154191830403D4D
3×2.55DH2 85641.911.5229272635463,04D4D
3×45DH2 85742.513.5319363454684D5,04D
3×65DH2 85843.215.5422464462784D5,03D
3×105DH2 86044.1217706461841054D5D
3×165DH2 83145.624.510608682981234D5,02D
3×255DH2 83246.828.515001131081141434D5,02D
3×355DH2 80548.13219701421351281604D5D
3×505DH2 80649.63727001771681481854D5D
3×705DH2 861411.24135202172071642054D5D
3×955DH2 773413.24745702632501882354D5D
3×1205DH2 774414.951.556203072922062584D5,01D
3×1855DH2 88541861.582404023822463084D5,01D
OZOFLEX H07RN-F · Four-core without PE · 4 rows
ConstructionLegacy material codeConductor ØODkg/kmA in airA on surfaceR fixedR movingRfixed/DRmoving/D
4×105DH2 82544.122.59306461901134D5,02D
4×165DH2 82645.627130086821081354D5D
4×255DH2 83746.831.518801131081261584D5,02D
4×355DH2 83848.135.524501421351421784D5,01D
OZOFLEX H07RN-F · Three-core with PE · 7 rows
ConstructionLegacy material codeConductor ØODkg/kmA in airA on surfaceR fixedR movingRfixed/DRmoving/D
3G15DH2 30351.28.9122161527363,03D4,04D
3G1.55DH2 30451.510154191830403D4D
3G2.55DH2 30551.911.5229272635463,04D4D
3G45DH2 30652.513.5319363454684D5,04D
3G65DH2 30753.215.5420464462784D5,03D
3G105DH2 31054.1217706461841054D5D
3G165DH2 31255.624.510608682981234D5,02D
OZOFLEX H07RN-F · Four-core with PE · 13 rows
ConstructionLegacy material codeConductor ØODkg/kmA in airA on surfaceR fixedR movingRfixed/DRmoving/D
4G15DH2 40351.29.8148161529392,96D3,98D
4G1.55DH2 40451.511192191833443D4D
4G2.55DH2 40551.913279272652654D5D
4G45DH2 40652.515388363460754D5D
4G65DH2 40753.217520464468854D5D
4G105DH2 41054.122.59306461901134D5,02D
4G165DH2 41255.627130086821081354D5D
4G255DH2 41356.831.518801131081261584D5,02D
4G355DH2 41458.135.524501421351421784D5,01D
4G505DH2 41559.64133801771681642054D5D
4G705DH2 416511.245.544502172071822284D5,01D
4G955DH2 417513.252.558302632502102634D5,01D
4G1205DH2 418514.95771003072922282854D5D
OZOFLEX H07RN-F · Five-core with PE · 8 rows
ConstructionLegacy material codeConductor ØODkg/kmA in airA on surfaceR fixedR movingRfixed/DRmoving/D
5G15DH2 50351.211186161533443D4D
5G1.55DH2 50451.512233191836483D4D
5G2.55DH2 50551.914335272656704D5D
5G45DH2 50652.516.5477363466834D5,03D
5G65DH2 50753.219640464476954D5D
5G105DH2 51054.125113064611001254D5D
5G165DH2 51255.629.5160086821181484D5,02D
5G255DH2 51356.83523101131081401754D5D
OZOFLEX H07RN-F · Multicore control · 6 rows
ConstructionLegacy material codeConductor ØODkg/kmA in airA on surfaceR fixedR movingRfixed/DRmoving/D
7G1.55DH2 58051.515.5370191862784D5,03D
7G2.55DH2 59051.918.5530272674934D5,03D
8G2.55DH2 59151.919.5590272678984D5,03D
12G2.55DH2 59351.9227702726881104D5D
18G2.55DH2 59551.926.5109027261061334D5,02D
24G2.55DH2 59651.930.5143027261221534D5,02D

9. OZOFLEX(PLUS) H07RN8-F full engineering matrix — 69 rows

OZOFLEX(PLUS) H07RN8-F · Single-core · 16 rows
ConstructionPartMLFBDminDmaxR fixedR movingkg/kmFmax NA airA waterIsc kA
1×1.5200080935DH10015.66.41919492333400.21
1×2.5not published5DH10026.372121503843520.36
1×4200036135DH10037.38.12432926059700.57
1×6201488435DH10047.98.726351159076910.86
1×10201488445DH10059.81133441861501061271.43
1×16201488455DH100610.611.835472572401421702.29
1×25200645875DH100712.914.156713713751882253.58
1×35200036145DH100814.315.562784765252322785.01
1×50200036155DH101016.51872906677502893477.15
1×70200036165DH101118.620.180101879105035842910.01
1×95200036175DH101221.923.4941171180142543151713.59
1×120200036185DH101323.424.91001251423180050460517.16
1×150200036885DH126026.328.51141431804225057869421.45
1×185200036835DH125228.530.71231542175277566079226.46
1×240200036875DH125831.8341361702804360078394034.32
1×300200036845DH125335.137.314918734074500906108742.9
OZOFLEX(PLUS) H07RN8-F · Two-core · 5 rows
ConstructionPartMLFBDminDmaxR fixedR movingkg/kmFmax NA airA waterIsc kA
2×1201567165DH12387.78.72635943019230.14
2×1.5200410455DH10748.69.629381164524290.21
2×2.5201631645DH10751011.635461697532380.36
2×4201631655DH107611.913.5546823912043520.57
2×6201638115DH107713.515.1607631418056670.86
OZOFLEX(PLUS) H07RN8-F · Three-core and 3G · 18 rows
ConstructionPartMLFBDminDmaxR fixedR movingkg/kmFmax NA airA waterIsc kA
3G1200036205DH10148.29.228371074519230.14
3G1.5200036215DH10159.410.431421426824290.21
3G2.5200073435DH101610.912.5506320711332380.36
3G4not published5DH101712.814.4587228918043520.57
3G6not published5DH101814.416.4668238427056670.86
3G10201729085DH102019.921.98811071245078931.43
3×1.5not published5DH10459.410.431421426824290.21
3×2.5not published5DH104610.912.5506320711332380.36
3×4not published5DH104712.814.4587228918043520.57
3×6not published5DH104814.416.4668238427056670.86
3×10201133195DH105019.921.98811069045078931.43
3×16201133205DH105123.525.51021289947201041252.29
3×25201144815DH105226.829.8119149137311251381653.58
3×35200166555DH105330.333.3133167184015751712055.01
3×50200036345DH105434.437.4150187241222502132557.15
3×70200036355DH105539.142.11682113322315026331610.01
3×95201512705DH105644.747.71912394150427531738013.59
3×120200419135DH105747512042555200540037144517.16
OZOFLEX(PLUS) H07RN8-F · Four-core with PE · 13 rows
ConstructionPartMLFBDminDmaxR fixedR movingkg/kmFmax NA airA waterIsc kA
4G1200036815DH12459.310.331411396019230.14
4G1.5200036225DH102110.211.835471779024290.21
4G2.5200036235DH10221213.6546825115032380.36
4G4200036245DH102313.815.4627734424043520.57
4G6200036255DH102416.118.1729148136056670.86
4G10200036265DH102521.223.29311684160078931.43
4G16200036275DH102625.328.311314212569601041252.29
4G25200036285DH102729.932.9132165181215001381653.58
4G35200036295DH102833.736.7147184231221001712055.01
4G50200036305DH103038.641.6166208301130002132557.15
4G70200036315DH103143.746.71872344230420026331610.01
4G95200036325DH103250.354.32172725536570031738013.59
4G120200036335DH103354.658.62342936724720037144517.16
OZOFLEX(PLUS) H07RN8-F · Five- and multicore control · 17 rows
ConstructionPartMLFBDminDmaxR fixedR movingkg/kmFmax NA airA waterIsc kA
5G1201722985DH124710.111.735471687519230.14
5G1.5200036825DH124611.112.7516421011324290.21
5G2.5200073865DH125013.314.9607530318832380.36
5G4201568645DH106115.617.6708843730043520.57
5G6200656555DH106216.618.6749355045056670.86
5G10not published5DH106323.626.6106133103675078931.43
5G16201824165DH106428.331.3125157152412001041252.29
6G1.5200036715DH122413.615.2617629713524290.21
7G1.5200036785DH108215.217.2698636215824290.21
8G1.5201888035DH108317.519.5789845218024290.21
10G1.5200036805DH108418208010047722524290.21
11G1.5not published5DH125518.120.18010149024824290.21
12G1.5200036685DH122117.219.2779648027024290.21
7G2.5200036725DH122717.519.5789850026332380.36
8G2.5200143735DH122818.720.78310456330032380.36
10G2.5200036755DH12342122.89111464737532380.36
12G2.5200036695DH122221.123.19211670845032380.36

10. OZOFLEX(PLUS) S07RN8H2-F flat matrix — 9 rows

ConstructionPartHminHmaxWminWmaxkg/km
3×162000831014.51730.534960
3×502000831121.52448522470
3×25 + 1G252022179817.519.548.651.61890
3×35 + 1G252017355419.52255602425
3×50 + 1G252017119322.524.56468.53300
3×70 + 1G3520167805242670744150
3×95 + 1G502017355327.529.578825430
3×120 + 1G702016780429.832.385906570
3×185 + 1G952016233636391021079725

11. OZOFLEX(FC+) S07RC4N8-F screened matrix — 12 rows

ConstructionPartDminDmaxkg/km4D fixed6D flexible
4G1.52000426812.814.426657.686.4
4G2.52000426915.217.238868.8103.2
4G420004270171951676114
4G62000427118.920.963083.6125.4
4G102000860323.125.1972100.4150.6
4G162000427226.629.61447118.4177.6
4G252015341631.834.82015139.2208.8
4G352000427435.338.32539153.2229.8
4G502000427540.543.53458174261
4G702005712645.248.24586192.8289.2
4G952017291050545350216324
4G120200259495760.56780242363

12. Document-generation conflicts

ProductFieldPublished positionsEngineering treatment
OZOFLEX H07RN-FConductor temperature2018 German brochure: 90°C; Nordic sheet: 60°CTreat as regional/product-generation difference; exact order sheet controls.
OZOFLEX H07RN-FShort-circuit temperature2018 German brochure: 250°C; Nordic sheet: 200°CDo not mix the higher value with the Nordic commercial list.
S07HXHXMaximum submersionOlder detailed catalogue: 2,000 m; 2025 overview: 500 mUse 500 m for current preliminary selection unless a current detailed sheet confirms otherwise.
S07RN8H2-FMaximum submersionOlder detailed catalogue: 2,000 m; 2025 overview: 500 mUse 500 m for current preliminary selection unless confirmed in writing.
H07RN8-FOuter-sheath description2016 matrix: CPE EM7; later catalogue page: EPDMKeep the generation distinction; request compound confirmation for chemical compatibility.
H07RN8-FTypical sewage-tank accessOlder engineering note: approximately 10 m in accessible tanks; product maximum: up to 2,000 m for suitable water typesAccessibility and chemical inspection remain separate from maximum hydrostatic depth.
Do not select by the largest published value: water depth, sheath compound and thermal limits must come from one confirmed current product sheet for the exact construction.

13. Classic H07RN-F versus H07RN8-F dimensional comparison

ConstructionOD classicOD wastewaterΔDmaxkg/km classickg/km wastewaterΔ mass
12G2.52221.1–23.11.1770708-62
1×10109.8–111202186-16
1×12024.523.4–24.90.415601423-137
1×1502726.3–28.51.519201804-116
1×161210.6–11.8-0.2279257-22
1×18529.528.5–30.71.223002175-125
1×2.56.56.3–70.57450-24
1×2403331.8–34129602804-156
1×2513.512.9–14.10.6407371-36
1×3003635.1–37.31.336103407-203
1×3515.514.3–15.50540476-64
1×47.57.3–8.10.610192-9
1×501816.5–180740667-73
1×68.37.9–8.70.4129115-14
1×7019.518.6–20.10.6980879-101
1×9522.521.9–23.40.912601180-80
2×18.37.7–8.70.410294-8
2×1.59.28.6–9.60.4128116-12
2×2.51110–11.60.6190169-21
2×412.511.9–13.51263239-24
3G18.98.2–9.20.3122107-15
3G1.5109.4–10.40.4154142-12
3G102119.9–21.90.9770712-58
3G2.511.510.9–12.51229207-22
3G413.512.8–14.40.9319289-30
3G615.514.4–16.40.9420384-36
3×1.5109.4–10.40.4154142-12
3×102119.9–21.90.9770690-80
3×12051.547–51-0.556205200-420
3×1624.523.5–25.511060994-66
3×2.511.510.9–12.51229207-22
3×2528.526.8–29.81.315001373-127
3×353230.3–33.31.319701840-130
3×413.512.8–14.40.9319289-30
3×503734.4–37.40.427002412-288
3×615.514.4–16.40.9422384-38
3×704139.1–42.11.135203322-198
3×954744.7–47.70.745704150-420
4G19.89.3–10.30.5148139-9
4G1.51110.2–11.80.8192177-15
4G1022.521.2–23.20.7930841-89
4G1205754.6–58.61.671006724-376
4G162725.3–28.31.313001256-44
4G2.51312–13.60.6279251-28
4G2531.529.9–32.91.418801812-68
4G3535.533.7–36.71.224502312-138
4G41513.8–15.40.4388344-44
4G504138.6–41.60.633803011-369
4G61716.1–18.11.1520481-39
4G7045.543.7–46.71.244504230-220
4G9552.550.3–54.31.858305536-294
5G11110.1–11.70.7186168-18
5G1.51211.1–12.70.7233210-23
5G102523.6–26.61.611301036-94
5G1629.528.3–31.31.816001524-76
5G2.51413.3–14.90.9335303-32
5G416.515.6–17.61.1477437-40
5G61916.6–18.6-0.4640550-90
7G1.515.515.2–17.21.7370362-8
7G2.518.517.5–19.51530500-30
8G2.519.518.7–20.71.2590563-27
The wastewater construction is not simply a thicker H07RN-F. Different sheath systems, water resistance and source generations can produce equal, larger or smaller published dimensions.

14. Representative engineering calculations

Three-phase comparison at 750 V: S = √3 × 0.75 kV × I P = S × 0.9Weight of 100 m: W = mass × 0.1 × gMinimum free loop: approximately 2 × published moving bending radiusHydrostatic pressure: p = ρgh 500 m fresh water ≈ 4.91 MPa 2,000 m fresh water ≈ 19.62 MPaThese values exclude dynamic pressure, density variation, chemical action and accessory limitations.
FamilyConstructionCurrent usedkVAkW @0.9Weight 100mLoop diameterOD/DmaxHydro reference
Classic H07RN-F4G35142184.51662.4 kN356 mm35.54.91 MPa @500m
Classic H07RN-F12G2.52735.131.60.76 kN220 mm224.91 MPa @500m
PLUS H07RN8-F4G35205266.3239.72.27 kN368 mm36.74.91 MPa @500m
PLUS H07RN8-F3×95380493.6444.34.07 kN478 mm47.74.91 MPa @500m
FC+ screened4G35205266.3239.72.49 kN459.6 mm38.34.91 MPa @500m

15. Source and inference audit

ItemFieldStatusTreatment
Classic H07RN-FMaterial codesLegacy technical codesRetained as legacy; not represented as current Part numbers.
H07RN8-FMissing Part numbersSeveral official rows publish only MLFBPart field remains blank; MLFB is retained.
Flat and FC+ matricesElectrical current and IscNot included in the published dimensional tables used hereNot inferred as source values.
FC+ representative calculationCurrentBorrowed from an equal H07RN8-F constructionShown only as a comparison assumption, not a confirmed FC+ ampacity.
S07HXHX and S07HXCHX-FFull dimensionsNo complete public matrix foundFamily limits are included, but no synthetic table is generated.
Water chemistryChemical resistanceMust be checked for aggressive or unusual compositionNo universal chemical-compatibility claim is made.

16. Engineering selection workflow

Engineering selection workflow 1. Environmentdry / wet / contaminated 2. Geometryround / flat / multicore 3. EMC & firescreen / halogen-free 4. Water systemdepth / chemistry / joints • Use H07RN-F for heavy-duty flexible industrial service, not as an automatic substitute for H07RN8-F. • Use PLUS wastewater variants for permanent immersion; select round, flat or halogen-free construction. • Use FC+ for converter-fed motors and bond the overall screen at both ends with low impedance. • Resolve document-generation conflicts before specifying water depth, sheath compound or conductor temperature. • Qualify the complete system: cable, gland, connector, repair joint, water temperature and chemical composition.

17. Installation and acceptance checklist

  • Confirm exact product: H07RN-F, H07RN8-F, S07HXHX, S07RN8H2-F, S07RC4N8-F or S07HXCHX-F.
  • Confirm round or flat shape, halogen-free requirement and converter/EMC requirement.
  • Use a current detailed sheet for maximum depth, conductor temperature and sheath compound.
  • Qualify the cable, gland, connector, repair joint and pump entry as a complete water-pressure system.
  • Review water chemistry for aggressive or unusual substances.
  • For FC+, bond the screen at both ends with a low-impedance, circumferential termination.
  • Verify conductor resistance, PE continuity, screen continuity and agreed insulation/withstand testing.
  • Record a baseline visual condition and check for sheath swelling, blistering, cracking or chemical attack during inspection.

18. Failure mode and effects analysis

Wrong family: ordinary H07RN-F is treated as a permanent wastewater cable.
Depth conflict: an older 2,000 m statement is used for a product shown at 500 m in the current overview.
Chemical incompatibility: depth compliance is assumed to prove resistance to every wastewater composition.
Accessory leakage: the cable rating is accepted without pressure-qualifying the gland or joint.
FC+ bonding failure: pigtail screen termination creates high impedance and poor EMC.
Thermal mixing: 90°C/250°C values from one H07RN-F document are applied to a 60°C/200°C regional product.

19. Source map and scope

DocumentRoleScope
Prysmian Submersible Pump Cable CatalogueCurrent family structure and detailed wastewater product pagesH07RN8-F, S07HXHX, S07RN8H2-F, S07RC4N8-F and S07HXCHX-F.
Prysmian Submersible Water Cables Overview, 2025Current overview limitsDepth, shape, screen and maximum cross-section mapping.
Prysmian Industry Cables General Catalogue, 2016Full H07RN8-F engineering matrix69 rows with dimensions, tensile force, air/water current and short-circuit current.
OZOFLEX H07RN-F product brochures and regional sheetHigh-flexibility construction and thermal comparisonHeavy-duty applications, EI4/EM2 construction and regional document differences.
This guide supports preliminary engineering and technical comparison. Current certificates, Part numbers, compounds, depth ratings and operating limits must be confirmed for the exact production batch.

Feichun Cable — OZOFLEX engineering support

Feichun Cable is not affiliated with the owners of OZOFLEX, OZOFLEX(PLUS), OZOFLEX(FC+) or the related designations. Diagrams are independent engineering reconstructions, not manufacturing drawings. Source, legacy and comparison values are explicitly separated.

FEICHUN-OZOFLEX-PLUS-HQ-FULL-SERIES-EN · 03/08/2026
Previous Article

SPREADERFLEX — Complete Basket, Vertical Reeling and Mobile Harbour Crane Series

Next Article

Feichun NTSCGEWOEU — высокогибкий средневольтный кабель для шахт, портовых кранов и барабанных систем

Write a Comment