RHEYFIRM® (RS) 与 RHEYFIRM® (RTS) 对比:何时选择 RHEYFIRM® KE 凯夫拉 (N)TSKCGECWÖU 超长垂直行程电缆

RHEYFIRM® (RS) vs. RHEYFIRM® (RTS): When to Choose RHEYFIRM® KE Kevlar (N)TSKCGECWÖU for Ultra-Long Vertical Travel
RHEYFIRM® (RS) 与 RHEYFIRM® (RTS) 对比:何时选择 RHEYFIRM® KE 凯夫拉 (N)TSKCGECWÖU 超长垂直行程电缆
1. Introduction to RHEYFIRM® Cable Series 概述
The RHEYFIRM® cable series represents the industry benchmark for flexible reeling and trailing cables designed for extreme mechanical stress applications. These cables are engineered to DIN VDE 0250-813 standards, which remain the globally recognized specification for tough rubber-sheathed flexible reeling cables used in cranes, mining equipment, and material handling machinery.
When vertical travel distances exceed conventional limits, particularly in deep shaft mining, high-rise elevator systems, and ship-to-shore crane applications, the selection between standard steel-reinforced cables and Kevlar (aramid fiber) reinforced alternatives becomes critical for operational safety and longevity.
Reference: Eland Cables – DIN VDE 0250 Standard
2. Cable Designation Nomenclature 电缆型号命名规则
Understanding the designation codes is essential for proper cable selection. The nomenclature follows DIN VDE conventions where each letter indicates specific construction features:
| Code 代码 | Meaning 含义 | Technical Significance 技术意义 |
|---|---|---|
| NN | Standardized cable 标准化电缆 | Manufactured to recognized national standards |
| TT | Trailing/Reeling cable 拖曳/卷筒电缆 | Designed for continuous flexing applications |
| SS | Reinforced sheath 加强护套 | Enhanced mechanical protection |
| KK | Kevlar/Aramid reinforcement 凯夫拉/芳纶加强 | Lightweight high-tensile strength member |
| CC | Metallic conductive layer 金属导电层 | EMC shielding capability |
| CGECGE | Non-metallic conductive layer on insulation 绝缘上的非金属导电层 | Electrical field control |
| WW | Control/monitoring wires 控制/监控线芯 | Integrated auxiliary circuits |
| ÖÖ | Oil resistant 耐油 | Suitable for industrial environments |
| UU | Flame retardant 阻燃 | Fire safety compliance |
3. RHEYFIRM® (RS) vs. RHEYFIRM® (RTS): Core Differences 核心差异
The distinction between RS and RTS designations relates to the intended operating conditions and mechanical stress profiles:
| Parameter 参数 | RHEYFIRM® (RS) (N)TSCGEWTOEUS | RHEYFIRM® (RTS) (N)TSCGEWTOEUS |
|---|---|---|
| Primary Application主要应用 | Ship-to-shore connections, moderate reeling速度 | High-speed reeling, extreme torsional stress 高速卷绕、极端扭转应力 |
| Reeling Speed卷绕速度 | Up to 120 m/min | Up to 190 m/min |
| Torsional Stress扭转应力 | Standard 标准 | Enhanced 增强 |
| Deflection Planes偏转平面 | Single plane preferred 单平面优先 | Multi-plane capable 多平面适用 |
| Voltage Rating额定电压 | 6/10 kV to 18/30 kV | 6/10 kV to 18/30 kV |
| Core Design线芯设计 | 3 phase + 2 earth conductors | 6-core (3 phase + 3 PE in interstices) |
| Typical Equipment典型设备 | Container vessels, ferries 集装箱船、渡轮 | STS cranes, RMG cranes, stackers STS起重机、RMG起重机、堆取料机 |
References: CSE Distributors – RHEYFIRM RTS | Nexans Germany – RHEYFIRM RTS Specifications
4. RHEYFIRM® KE Kevlar (N)TSKCGECWÖU: Ultra-Long Vertical Travel Solution 超长垂直行程解决方案
For applications requiring vertical travel distances exceeding 300 meters, conventional steel-reinforced cables face significant limitations due to self-weight loading. The RHEYFIRM® KE series incorporates Kevlar (aramid fiber) reinforcement to address these challenges.
4.1 Kevlar Reinforcement Advantages 凯夫拉加强优势
Kevlar Aramid Fiber Properties 凯夫拉芳纶纤维特性
According to DuPont technical documentation, Kevlar aramid fiber provides strength comparable to steel while maintaining only 14-15% of the weight. This characteristic makes Kevlar-reinforced cables the optimal choice for ultra-long vertical applications where cable self-weight becomes a limiting factor.
Reference: DuPont – Kevlar® Ropes and Cables
4.2 (N)TSKCGECWÖU Technical Specifications 技术规格
| Specification 规格 | Value 数值 | Standard 标准 |
|---|---|---|
| Voltage Rating额定电压 | 3.6/6 kV to 12/20 kV | DIN VDE 0250-813 |
| Conductor导体 | Tinned copper, Class 5 flexible | DIN VDE 0295 / IEC 60228 |
| Insulation绝缘 | EPR type 3GI3 | DIN VDE 0207-20 |
| Sheath护套 | Synthetic thermosetting 5GM5 | DIN VDE 0207-21 |
| Reinforcement加强件 | Kevlar aramid fiber core | Proprietary design |
| Temperature Range温度范围 | -25°C to +90°C (mobile) | DIN VDE 0298-3 |
| Min. Bending Radius最小弯曲半径 | 8× cable diameter | DIN VDE 0298-3 |
| Oil Resistance耐油性 | Yes 是 | DIN VDE 0472 |
| Flame Retardant阻燃 | IEC 60332-1-2 compliant | EN 60332-1-2 |
References: Tratos Group – Mining Cables NTSKCGECWÖU | TF Kable Mining Cable Catalogue
5. Steel vs. Kevlar Reinforcement: Comparative Analysis 钢丝与凯夫拉加强对比分析
| Parameter 参数 | Steel Wire Reinforced 钢丝加强 | Kevlar Aramid Reinforced 凯夫拉芳纶加强 |
|---|---|---|
| Weight Efficiency重量效率 | Standard baseline 标准基准 | 60-70% weight reduction |
| Tensile Modulus拉伸模量 | ≈200,000 N/mm² | ≈100,000 N/mm² |
| Max. Vertical Travel最大垂直行程 | Limited by self-weight | Extended capability |
| Crush Resistance抗压性 | Excellent 优秀 | Moderate (relies on sheath) |
| Corrosion Resistance耐腐蚀性 | Requires galvanization | Inherently resistant |
| Fatigue Performance疲劳性能 | Good 良好 | Excellent 优秀 |
| UV Resistance抗紫外线 | Not affected 不受影响 | Requires protection |
| Cost Factor成本因素 | Lower initial cost | Higher initial, lower lifecycle |
| Electrical Properties电气特性 | Conductive (grounding) | Non-conductive 非导电 |
The engineering decision between steel and Kevlar reinforcement depends on the specific vertical travel requirements and operating conditions. For deep shaft mining hoists exceeding 500 meters, Kevlar reinforcement provides significant advantages in reducing total suspended cable weight while maintaining required tensile strength.
Reference: DeRegt Cables – Steel vs. Aramid Fibre Comparison
6. Application Selection Guidelines 应用选型指南
Deep Shaft Mining Hoists 深井矿山提升机
Recommended 推荐: RHEYFIRM® KE (N)TSKCGECWÖU
Vertical travel >300m requires Kevlar reinforcement to manage cable self-weight. The non-conductive nature of aramid fibers provides additional safety in potentially explosive atmospheres.
Ship-to-Shore Cranes (STS) 岸桥起重机
Recommended 推荐: RHEYFIRM® (RTS) (N)TSCGEWTOEUS
High reeling speeds up to 190 m/min with multi-plane deflection capability. Integrated optical fiber options available for data transmission.
Open-Pit Mining Excavators 露天矿挖掘机
Recommended 推荐: RHEYFIRM® (RTS) R-(N)TSCGEWTOEUS
Level-wind reel applications with high torsional stress. Steel reinforcement provides crush resistance for drum winding.
High-Rise Elevator Systems 高层电梯系统
Recommended 推荐: Kevlar-core traveling cable
Travel heights >160m benefit from Kevlar reinforcement. Reduced cable weight enables smaller pulleys and lower energy consumption.
6.1 Decision Matrix: When to Choose Kevlar 何时选择凯夫拉加强
| Condition 条件 | Steel Reinforcement 钢丝加强 | Kevlar Reinforcement 凯夫拉加强 |
|---|---|---|
| Vertical travel <200m 垂直行程<200米 | ✓ Preferred 优选 | Optional 可选 |
| Vertical travel 200-400m | Acceptable 可接受 | ✓ Recommended 推荐 |
| Vertical travel >400m | Not recommended 不推荐 | ✓ Required 必需 |
| High reeling speed (>150 m/min) | ✓ Preferred 优选 | Acceptable 可接受 |
| Corrosive environment 腐蚀环境 | Requires protection | ✓ Preferred 优选 |
| Crush/abrasion exposure 压碎/磨损 | ✓ Preferred 优选 | Requires sheath protection |
| Weight-sensitive systems 重量敏感系统 | Limited application | ✓ Preferred 优选 |
7. Standards Compliance Summary 标准合规性总结
Applicable Standards 适用标准
References: Feichun Cables – DIN VDE 0250 Overview | Prysmian – Medium Voltage Reeling Cables
Contact Anhui Feichun Special Cable Co., Ltd. 联系安徽飞纯特种电缆有限公司
For technical consultation on RHEYFIRM® equivalent cables, custom Kevlar-reinforced cable solutions, or project-specific engineering support, our experienced team is ready to assist.
如需RHEYFIRM®同等电缆技术咨询、定制凯夫拉加强电缆方案或项目工程支持,欢迎联系我们的专业团队。
References & External Sources 参考资料与外部来源
- Eland Cables. “DIN VDE 0250 Standard Cable.” elandcables.com
- CSE Industrial Electrical Distributors. “RHEYFIRM®(RTS) (N)TSCGEWTOEUS Cable.” cse-distributors.co.uk
- Nexans Deutschland GmbH. “RHEYFIRM® (RTS) R-(N)TSCGEWTOEUS 8.7/15 kV.” nexans.de
- DuPont. “Kevlar® Ropes and Cables Applications.” dupont.com
- Tratos Group. “Mining and Tunneling Cables – DIN VDE 250 Part 813.” tratosgroup.com
- DeRegt Cables. “Steel vs. Aramid Fibre – Cable Solution Comparison.” deregtcables.com
- Prysmian Group. “PROTOLON Medium Voltage Reeling Cables – DIN VDE 0250-813.” prysmian.com
- CED Elevator. “Traveling Cable Selection Guide.” cedelevator.com