耐火電纜系列 — 緊急逃生系統生命安全電纜

Firecross Fire Resistant Cable Family
耐火電纜系列 — 緊急逃生系統生命安全電纜
Firecross cables are engineered to maintain circuit integrity during extreme fire conditions, ensuring emergency systems continue operating when lives depend on them. Available in Standard 60-minute and Enhanced 120-minute fire ratings with 2, 3, and 4 core configurations plus Circuit Protective Conductor (CPC), these cables serve critical life safety applications including fire alarms, voice communication systems, emergency lighting, air conditioning controls, and lift door mechanisms.
Firecross 電纜經過精心設計,可在極端火災條件下保持電路完整性,確保緊急系統在生命攸關時繼續運行。提供標準 60 分鐘和增強 120 分鐘耐火等級,配備 2、3 和 4 芯配置加電路保護導體 (CPC),這些電纜服務於關鍵生命安全應用,包括火災警報、語音通訊系統、緊急照明、空調控制和電梯門機構。
Life Safety Critical: Circuit Integrity Under Fire 生命安全關鍵:火災下的電路完整性
English: In a fire emergency, standard cables fail quickly as insulation burns away and conductors short-circuit. Firecross fire resistant cables are constructed with specialized mica tape barriers and fire-resistant insulation that maintain circuit integrity even when directly exposed to flames. This ensures fire alarms continue sounding, emergency lighting remains operational, voice communication systems broadcast evacuation instructions, and lift doors remain controllable—all critical functions that save lives during building evacuations.
繁體中文:在火災緊急情況下,標準電纜會隨著絕緣層燒毀和導體短路而迅速失效。Firecross 耐火電纜採用專門的雲母帶屏障和耐火絕緣層構建,即使直接暴露在火焰中也能保持電路完整性。這確保火災警報持續響起、緊急照明保持運行、語音通訊系統廣播疏散指示,以及電梯門保持可控——所有這些關鍵功能在建築物疏散期間挽救生命。
2CFC
Standard 60
2CEFC
Enhanced 120
3CFC
Standard 60
4CFC
Standard 60
4CEFC
Enhanced 120
Product Overview 產品概述
The Firecross cable family is manufactured to BS 7629-1, the British Standard for fire resistant cables designed for emergency circuits. Unlike standard cables that rely solely on PVC or XLPE insulation, Firecross cables incorporate multiple layers of protection including mica tape barriers wrapped around each conductor. Mica is a naturally occurring mineral with exceptional thermal stability that maintains its insulating properties even at temperatures exceeding 1000°C, providing the critical barrier that prevents conductor short-circuits during fire exposure.
The range offers both Standard 60 and Enhanced 120 ratings, referring to the duration in minutes that the cable maintains circuit integrity under standardized fire test conditions. Standard 60 cables (2CFC, 3CFC, 4CFC) suit most commercial fire alarm and emergency lighting installations, while Enhanced 120 cables (2CEFC, 4CEFC) serve applications requiring extended fire survival such as high-rise buildings, hospitals, transport terminals, and structures with complex evacuation requirements.
All models include an integrated Circuit Protective Conductor (CPC) that provides the earth connection required by BS 7671 wiring regulations, eliminating the need for separate earth cables and simplifying installation. The solid copper conductors and robust construction ensure reliable long-term performance in both normal operation and fire emergency conditions.
Firecross 電纜系列根據 BS 7629-1 製造,這是專為緊急電路設計的耐火電纜英國標準。與僅依賴 PVC 或 XLPE 絕緣的標準電纜不同,Firecross 電纜包含多層保護,包括纏繞在每根導體周圍的雲母帶屏障。雲母是一種天然礦物,具有出色的熱穩定性,即使在超過 1000°C 的溫度下也能保持其絕緣性能,提供防止火災暴露期間導體短路的關鍵屏障。
該系列提供標準 60 和增強 120 額定值,指的是電纜在標準化火災測試條件下保持電路完整性的持續時間(分鐘)。標準 60 電纜(2CFC、3CFC、4CFC)適用於大多數商業火災警報和緊急照明安裝,而增強 120 電纜(2CEFC、4CEFC)服務於需要延長耐火存活的應用,如高層建築、醫院、交通樞紐和具有複雜疏散要求的結構。
所有型號都包括一個集成的電路保護導體 (CPC),提供 BS 7671 佈線規則要求的接地連接,無需單獨的接地電纜,簡化安裝。實心銅導體和堅固的結構確保在正常運行和火災緊急條件下都能可靠地長期運行。
📋 Common Specifications Across All Models 所有型號共同規格
Technical Specifications 技術規格
BS 7629-1 Standard 60 | Fire Alarms, Emergency Lighting, Critical Systems
| Product Code | Core Size (mm²) | Conductor | Diameter (mm) | Current (A) | Resistance (Ω/km) | Lengths (m) | Usage |
|---|---|---|---|---|---|---|---|
| 2CFC1.5 | 1.5 | Solid | 7.85 | 19.5 | 12.1 | 100 | Fire alarms, emergency lighting |
| 2CFC2.5 | 2.5 | Solid | 9.20 | 27 | 7.41 | 100 | Fire alarms, emergency lighting |
| 2CFC4.0 | 4.0 | Solid | 11.90 | 36 | 4.61 | 100 | Fire alarms, critical systems |
BS 7629-1 Enhanced 120 | Extended Fire Survival for Critical Applications
| Product Code | Core Size (mm²) | Conductor | Diameter (mm) | Current (A) | Resistance (Ω/km) | Lengths (m) | Usage |
|---|---|---|---|---|---|---|---|
| 2CEFC1.5 | 1.5 | Solid | 8.25 | 19.5 | 12.1 | 100 | Fire alarms, emergency lighting |
BS 7629-1 Standard 60 | Three-Phase Emergency Systems
| Product Code | Core Size (mm²) | Conductor | Diameter (mm) | Current (A) | Resistance (Ω/km) | Lengths (m) | Usage |
|---|---|---|---|---|---|---|---|
| 3CFC1.5 | 1.5 | Solid | 8.8 | 19.5 | 12.1 | 100 | Fire alarms, emergency lighting |
| 3CFC2.5 | 2.5 | Solid | 9.7 | 27 | 7.41 | 100 | Fire alarms, critical systems |
BS 7629-1 Standard 60 | Multi-Circuit Emergency Systems
| Product Code | Core Size (mm²) | Conductor | Diameter (mm) | Current (A) | Resistance (Ω/km) | Lengths (m) | Usage |
|---|---|---|---|---|---|---|---|
| 4CFC1.5 | 1.5 | Solid | 9.40 | 19.5 | 12.1 | 100 | Fire alarms, emergency lighting |
| 4CFC2.5 | 2.5 | Solid | 11.60 | 27 | 7.41 | 100 | Fire alarms, critical systems |
BS 7629-1 Enhanced 120 | Extended Fire Survival Multi-Circuit
| Product Code | Core Size (mm²) | Conductor | Diameter (mm) | Current (A) | Resistance (Ω/km) | Lengths (m) | Usage |
|---|---|---|---|---|---|---|---|
| 4CEFC1.5 | 1.5 | Solid | 9.70 | 19.5 | 4.61 | 100 | Fire alarms, emergency lighting |
💡 Selection Guide: Standard vs Enhanced 選擇指南:標準 vs 增強
Standard 60 (2CFC, 3CFC, 4CFC)
Suitable for most commercial and industrial buildings with standard evacuation times. Offices, retail premises, schools, warehouses, and low-rise residential buildings typically require Standard 60 fire resistant cables as specified by building regulations.
Enhanced 120 (2CEFC, 4CEFC)
Required for buildings with extended evacuation times or higher fire risk profiles. High-rise buildings (typically >18m), hospitals, care homes, transport terminals, underground structures, and buildings with phased evacuation procedures require Enhanced 120 cables.
2 Core (2CFC, 2CEFC)
Single-phase circuits for fire alarms, emergency lighting luminaires, voice alarm speakers, and smoke detectors. The most common configuration for distributed emergency systems throughout a building.
3 Core (3CFC)
Three-phase emergency power supplies, larger emergency lighting installations, and systems requiring neutral connections. Also used for maintained emergency lighting with separate switching.
4 Core (4CFC, 4CEFC)
Multi-circuit applications including lift door mechanisms, air conditioning fire mode controls, and complex emergency systems requiring multiple independent circuits within a single cable run.
Conductor Size Selection
1.5mm² (19.5A): Most fire alarm circuits and standard emergency lighting. 2.5mm² (27A): Longer cable runs or higher load circuits. 4.0mm² (36A): Heavy emergency systems or voltage drop compensation over extended distances.
Typical Applications 典型應用
Fire Alarm Systems 火災警報系統
Detection & notification
偵測和通知
Emergency Lighting 緊急照明
Escape route illumination
逃生路線照明
Voice Communication 語音通訊
PA & evacuation systems
廣播和疏散系統
Lift Door Control 電梯門控制
Emergency operation
緊急操作
Air Conditioning 空調系統
Fire mode controls
火災模式控制
Hospitals 醫院
Critical care systems
重症監護系統
High-Rise Buildings 高層建築
Extended evacuation
延長疏散
Transport Terminals 交通樞紐
Public safety systems
公共安全系統
Key Features 主要特性
Mica Tape Fire Barrier 雲母帶耐火屏障
Each conductor is wrapped with mica tape that maintains insulation integrity at temperatures exceeding 1000°C, preventing short circuits during direct flame exposure.
每根導體都包裹雲母帶,在超過 1000°C 的溫度下保持絕緣完整性,防止直接火焰暴露期間短路。
60/120 Minute Ratings 60/120分鐘額定
Standard 60 or Enhanced 120 minute fire survival ratings certified to BS 7629-1, meeting requirements for different building types and evacuation scenarios.
根據 BS 7629-1 認證的標準 60 或增強 120 分鐘耐火存活額定,滿足不同建築類型和疏散場景的要求。
Integrated CPC Earth 集成CPC接地
Built-in Circuit Protective Conductor eliminates need for separate earth cables, simplifying installation while ensuring BS 7671 compliance.
內置電路保護導體無需單獨的接地電纜,簡化安裝同時確保符合 BS 7671。
Wide Temperature Range 寬溫度範圍
Operating range from -40°C to +90°C ensures reliable performance in cold storage facilities, outdoor installations, and high ambient temperature environments.
-40°C 至 +90°C 的工作範圍確保在冷藏設施、戶外安裝和高環境溫度環境中可靠運行。
250°C Short Circuit Rating 250°C短路額定
High short-circuit temperature rating allows the cable to withstand fault currents without immediate failure, maintaining circuit protection.
高短路溫度額定使電纜能夠承受故障電流而不會立即失效,保持電路保護。
BS 7629-1 Certified BS 7629-1認證
Full compliance with British Standard for fire resistant cables ensures acceptance by building control, insurance providers, and fire safety authorities.
完全符合耐火電纜英國標準,確保獲得建築控制、保險提供商和消防安全機構的認可。
Standards & Compliance 標準與合規
British Standard specifying requirements for cables that maintain circuit integrity under fire conditions for 60 or 120 minutes
BSI Group Reference →Code of practice for design, installation, commissioning and maintenance of fire detection and alarm systems in buildings
BSI Group Reference →Code of practice for the emergency lighting of premises covering design, installation, wiring and testing requirements
BSI Group Reference →Requirements for electrical installations including fire resistant cable selection and installation methods
IET Wiring Regulations →European standard test method for small diameter cables used in emergency circuits
CENELEC Reference →UK building regulations guidance on fire safety including requirements for fire resistant cables in emergency systems
UK Government Reference →Authoritative References 權威參考資料
- British Standards Institution. (2020). BS 7629-1 Electric cables — Thermosetting insulated, armoured, fire resistant cables. BSI
- British Standards Institution. (2019). BS 5839-1 Fire detection and fire alarm systems for buildings. BSI
- British Standards Institution. (2016). BS 5266-1 Emergency lighting — Code of practice. BSI
- Institution of Engineering and Technology. (2022). BS 7671:2018+A2:2022 Wiring Regulations. IET
- HM Government. (2022). Approved Document B: Fire Safety. GOV.UK
- Fire Industry Association. (2023). Code of Practice for Fire Detection and Alarm Systems. FIA
Contact Us 聯繫我們
For technical consultation, quotations, or customized fire resistant cable solutions for your life safety systems, please contact our professional team.
WhatsApp: +86 138 5512 3218