TUNNELFLEX-PUR HF WITHOUT ANTITWISTING PROTECTION I 1 KV

无抗扭保护隧道柔性聚氨酯电缆

TUNNELFLEX-PUR HF represents a specialized category of halogen-free flexible power cables engineered for mobile equipment operating in mining and tunnelling environments where high mechanical damage risk is inherent. This cable variant, manufactured without antitwisting protection elements, is optimally designed for applications where cable deflection occurs predominantly in a single plane, eliminating the need for complex anti-torsion structures while maintaining robust mechanical performance and safety characteristics critical to underground operations. 该电缆为无卤柔性电力电缆,专为存在高机械损伤风险的采矿和隧道移动设备供电而设计。由于没有抗扭保护,适用于仅在单一平面内偏转的应用场合,最大运行速度为60米/分钟。
TUNNELFLEX-PUR HF represents a specialized category of halogen-free flexible power cables engineered for mobile equipment operating in mining and tunnelling environments where high mechanical damage risk is inherent. This cable variant, manufactured without antitwisting protection elements, is optimally designed for applications where cable deflection occurs predominantly in a single plane, eliminating the need for complex anti-torsion structures while maintaining robust mechanical performance and safety characteristics critical to underground operations.

该电缆为无卤柔性电力电缆,专为存在高机械损伤风险的采矿和隧道移动设备供电而设计。由于没有抗扭保护,适用于仅在单一平面内偏转的应用场合,最大运行速度为60米/分钟。
TUNNELFLEX-PUR HF 1 KV – Halogen-Free Mining Cable | Anhui Feichun Special Cable

TUNNELFLEX-PUR HF WITHOUT ANTITWISTING PROTECTION I 1 KV 无抗扭保护隧道柔性聚氨酯电缆

Anhui Feichun Special Cable Co., Ltd.
安徽飞纯特种电缆有限公司

Product Overview 产品概述

The TUNNELFLEX-PUR HF represents a specialized category of halogen-free flexible power cables engineered for mobile equipment operating in mining and tunnelling environments where high mechanical damage risk is inherent. This cable variant, manufactured without antitwisting protection elements, is optimally designed for applications where cable deflection occurs predominantly in a single plane, eliminating the need for complex anti-torsion structures while maintaining robust mechanical performance and safety characteristics critical to underground operations.

该电缆为无卤柔性电力电缆,专为存在高机械损伤风险的采矿和隧道移动设备供电而设计。由于没有抗扭保护,适用于仅在单一平面内偏转的应用场合,最大运行速度为60米/分钟。

Application Limitation: This cable is specifically designed for deflection in one plane only. For applications involving multi-plane deflection, torsional stress, or twisting movements, alternative cable designs with anti-twisting protection must be specified to prevent premature failure and ensure safe operation.

Technical Specifications 技术规格

Standard Cable Configurations 标准电缆配置

Configuration
配置
Conductor Ø
(mm)
导体直径
Cable Ø Min
(mm)
最小电缆直径
Cable Ø Max
(mm)
最大电缆直径
Cable Weight
(kg/km)
电缆重量
Max Tensile
Strength (N)
最大抗拉强度
Bending Radius
Fixed Min (mm)
弯曲半径
Current
Capacity (A)
载流量
4G104.018.020.058080012074
4G165.120.022.08701,28013299
3×25+3G66.522.524.01,1201,500144131
3×35+3G67.525.528.01,4902,100168162
3×50+3G109.129.532.02,1003,000192202
3×70+3G1610.834.037.02,9604,200222250
3×95+3G1612.137.540.53,6405,700243301
3×120+3G2514.342.045.04,7507,200270352
3×150+3G2516.147.550.55,7409,000303404
3×185+3G3517.552.055.06,96011,100330461
3×240+3G5019.958.061.09,13014,400366540

Configurations with Control Cores 带控制芯线配置

Configuration
配置
Conductor Ø
(mm)
导体直径
Cable Ø Min
(mm)
最小电缆直径
Cable Ø Max
(mm)
最大电缆直径
Cable Weight
(kg/km)
电缆重量
Max Tensile
Strength (N)
最大抗拉强度
Bending Radius
Fixed Min (mm)
弯曲半径
Current
Capacity (A)
载流量
3×25+3G6+2×16.522.524.01,1501,500144131
3×35+3G6+2×1.57.526.028.01,5302,100168162
3×50+3G10+2×1.59.129.532.02,1303,000192202
3×70+3G16+2×1.510.834.037.02,9904,200222250
3×95+3G16+2×1.512.137.540.53,6705,700243301
3×120+3G25+2×1.514.342.045.04,7807,200270352
3×150+3G25+2×1.516.147.550.55,7809,000303404
3×185+3G35+2×1.517.552.055.07,00011,100330461
3×240+3G50+2×1.519.958.061.09,17014,400366540

Structural Components 结构组成

Conductor 导体
Plain copper, flexible, Class 5 according to IEC 60228 standard for maximum flexibility
Core Insulation 芯线绝缘
Cross-linked polyethylene (XLPE) special compound providing superior electrical properties
Core Identification 芯线识别
Brown, Black, Grey for phase conductors; color-coded per DIN VDE 0298-300
Core Arrangement 芯线排列
Phase cores laid up with earth cores positioned in the interstices for balanced structure
Earth Core 接地芯线
Plain copper conductor, flexible Class 5, integrated within cable structure
Control Cores 控制芯线
Optional – 2 x 1.5 mm² for signaling and equipment control functions
Inner Sheath 内护套
HFFR (Halogen-Free Flame Retardant) thermoplastic polyurethane compound
Outer Sheath 外护套
HFFR thermoplastic polyurethane – abrasion, tear, oil & chemical resistant

The Class 5 conductor designation per IEC 60228 represents the most flexible category of stranded conductors, essential for mobile cable applications requiring repeated flexing. Source: IEC 60228 Standard

Standards & Approvals 标准和认证

DIN EN 60228 / IEC 60228 / VDE 0295 – Conductors of insulated cables. This fundamental international standard establishes requirements for conductor materials, construction, dimensions, and electrical resistance values. Class 5 conductors specified in this standard provide the highest flexibility for applications requiring frequent bending and movement.

DIN VDE 0298-300 – Core identification standards establishing uniform color coding systems. Consistent core identification is critical in underground mining installations where maintenance personnel must quickly and accurately identify conductors during troubleshooting, repair, or modification work under challenging visibility conditions.

IEC 60754-1 – Test on gases evolved during combustion of materials from cables – Part 1: Determination of the halogen acid gas content. This critical test method determines the amount of halogen acid gas released during cable combustion. Cables meeting halogen-free criteria release less than 5 mg/g of halogen acid when burned, significantly reducing toxic gas hazards in confined underground spaces.

DIN EN 60332-1-2 / IEC 60332-1-2 – Fire performance testing for single vertical insulated wire or cable. This test subjects a single cable to a standardized 1 kW flame for 60 seconds to verify that the cable will self-extinguish and not propagate flame beyond specified limits, essential for preventing fire spread in underground tunnels.

The IEC 60754-1 standard addresses a critical safety concern in underground environments. During combustion, halogenated materials release hydrogen chloride, hydrogen bromide, and other corrosive, toxic gases that severely impede evacuation efforts and cause extensive damage to electronic equipment and infrastructure. Source: IEC Webstore – IEC 60754-1. Cables releasing less than 5 mg/g halogen acid are classified as halogen-free (LSOH – Low Smoke Zero Halogen), while those between 5-15 mg/g are low halogen (LSF – Low Smoke Fume).

Fire testing according to IEC 60332-1-2 requires that flame damage not exceed 50mm from the upper mounting point, and the cable must self-extinguish within a defined period after flame source removal. Source: VTEC Laboratories. This ensures cables do not become fuel sources that could transform a localized incident into a major fire event.

Thermal Parameters 热特性参数

Maximum Conductor Temperature 最高导体温度
90°C during continuous normal operation
Short Circuit Temperature 短路温度
250°C maximum for fault duration not exceeding 5 seconds
Fixed Installation – Minimum Ambient 固定安装最低环境温度
-40°C for stationary permanently installed cables
Fixed Installation – Maximum Ambient 固定安装最高环境温度
+80°C for stationary installations in hot environments
Flexible Installation – Minimum Ambient 柔性安装最低环境温度
-30°C for mobile equipment during active operation
Flexible Installation – Maximum Ambient 柔性安装最高环境温度
+80°C for mobile equipment in high-temperature zones
Temperature Rating Explanation: The 90°C continuous conductor temperature rating represents the maximum temperature the conductor can sustain during normal operation without degrading insulation properties or reducing cable service life. The 250°C short circuit rating allows the cable to withstand brief fault currents without catastrophic failure, providing critical safety time for protective devices to operate and isolate the fault.

Chemical & Fire Behavior Parameters 化学和燃烧特性参数

Fire Behavior 燃烧特性
Yes – designed with inherent fire resistance characteristics
Flame Retardant 阻燃性能
In accordance with EN/IEC 60332-1-2 single vertical wire test
Halogen Free 无卤素
Yes – compliant with IEC 60754-1 requirements (< 5 mg/g halogen acid)
Halogen-Free Significance: The halogen-free construction addresses two critical safety concerns in underground mining. First, during fire events, halogen-free cables produce minimal corrosive acid gases, protecting both personnel during evacuation and expensive electrical/electronic equipment not directly involved in the fire. Second, the absence of halogens reduces toxic smoke density, improving visibility during emergency evacuation and facilitating firefighting operations in confined tunnel spaces.

According to IEC 60754-1 testing methodology, cable samples are combusted at 800°C and the evolved gases are collected and analyzed for halogen acid content. Materials releasing less than 5 mg/g qualify as halogen-free. Source: EN Standard – BS EN 60754-1

Mechanical Parameters 机械参数

Travel Speed 运行速度
60 m/min maximum operational velocity for mobile equipment
Bending Radius – Fixed Installation 固定安装弯曲半径
6 x D (cable outer diameter) according to VDE 0298-3
Bending Radius – On Drums 卷筒弯曲半径
10 x D (cable outer diameter) for drum-mounted applications

The VDE 0298-3 standard establishes minimum bending radii to prevent mechanical damage during installation and operation. Bending cables to radii smaller than specified values can cause conductor strand breakage, insulation cracking, and premature cable failure. Source: HalleyCables – VDE 0298-3 Bending Radius. The 10 x D requirement for drum applications reflects the more severe mechanical stress imposed by repeated winding and unwinding cycles compared to fixed installations.

Critical Mechanical Limitation: This cable design specifically lacks antitwisting protection elements. It must only be used in applications where cable movement is restricted to a single plane. Multi-plane deflection, torsional stress, or twisting movements will cause rapid cable degradation and potential failure. For applications involving rotation, spiraling paths, or complex three-dimensional movement patterns, cables with integrated anti-torsion elements must be specified.

Electrical Parameters 电气参数

Rated Voltage U₀/U (Um) 额定电压
0.6/1 kV (1.2 kV) where U₀ = conductor-to-earth, U = conductor-to-conductor
Maximum Operating Voltage 最高工作电压
Um = 1.2 kV representing maximum sustained system voltage
Test Voltage 测试电压
3.5 kV AC applied during routine electrical testing for quality verification

The voltage designation 0.6/1 kV indicates the cable is rated for 600V between any conductor and ground, and 1000V between phase conductors. The Um value of 1.2 kV represents the maximum voltage the system may experience, typically 20% above nominal to account for voltage regulation variations and transient overvoltages.

Application Guidelines 应用指南

The TUNNELFLEX-PUR HF cable is engineered for power supply to mobile equipment operating in mining and tunnelling environments characterized by high mechanical damage risk. The cable’s halogen-free polyurethane outer sheath provides exceptional resistance to the abrasion, tearing, oil exposure, and chemical contact commonly encountered in underground operations. The maximum travel speed of 60 meters per minute accommodates typical mobile mining equipment velocities while ensuring the cable experiences manageable mechanical stress levels.

该电缆用于在采矿和隧道环境中为存在高机械损伤风险的移动设备供电。由于没有抗扭保护,适用于仅在单一平面内偏转的应用。最大运行速度为60米/分钟。

The absence of antitwisting protection elements makes this cable particularly suitable for applications such as conveyor systems moving in straight lines, shuttle cars traveling along fixed rail paths, ventilation fan installations where cables hang vertically with minimal lateral movement, and other scenarios where cable motion is constrained to predominantly linear or single-plane curved paths. This design choice reduces cable weight, diameter, and cost while maintaining necessary mechanical strength for the intended application envelope.

Typical Applications: Linear conveyor belt systems, rail-mounted shuttle cars, vertical ventilation shaft installations, straight-line material transport equipment, and fixed-path mobile machinery where deflection occurs primarily in one plane. The 60 m/min travel speed rating accommodates most underground mining vehicle and equipment velocities while providing adequate safety margin against mechanical fatigue.

Mining cables must address unique environmental challenges including limited ventilation, presence of moisture and mineral dust, mechanical abuse from equipment and falling debris, and the critical safety requirement that cables do not contribute to fire propagation or produce toxic fumes during emergency situations. Source: Mining Cables Technical Reference

Installation Considerations 安装注意事项

Proper installation of TUNNELFLEX-PUR HF cables requires attention to several critical factors. The minimum bending radius of 6 x D for fixed installations and 10 x D for drum mounting must be strictly observed to prevent insulation damage and conductor stress. Installation personnel should verify that cable routes involve primarily single-plane deflection, as the absence of antitwisting protection makes this cable unsuitable for applications involving rotation or multi-dimensional movement.

Ambient temperature during installation should be maintained between -30°C and +80°C for mobile applications. At temperatures below the minimum specification, the cable sheath becomes less flexible and more susceptible to cracking during handling. Cable pulling tensions should not exceed the maximum tensile strength values specified for each configuration, and appropriate strain relief must be provided at termination points to prevent mechanical stress concentration.

Installation Safety Warning: Before installation, verify that the application environment matches the cable’s design limitations. This cable is NOT suitable for applications involving torsional stress, multi-plane deflection, or rotational movement. Using this cable in unsuitable applications will result in premature failure and potential safety hazards. When in doubt, consult with technical specialists to confirm appropriate cable selection.

Contact Information 联系方式

Company: Anhui Feichun Special Cable Co., Ltd. (安徽飞纯特种电缆有限公司)

WhatsApp: +86 13855 123218

Technical Email: [email protected]

Sales Contact: [email protected]

Engineering Contact: [email protected]

© 2024 Anhui Feichun Special Cable Co., Ltd. All specifications subject to technical modifications without notice.

本页面所有规格参数如有技术改进恕不另行通知 | All external links are provided for reference purposes and use the nofollow attribute

Previous Article

TROMMELFLEX-M-PUR BRAIDED D2X11Y 1 KV

Next Article

PROTOLON (SB) NTSCGEWOEU I 3 – 30 KV