An engineering guide to a cold- and UV-resistant PVC power, control and connecting cable for plant and machine building, HVAC, frozen-goods plants, cold stores and outdoor equipment in extreme climates.

ÖPVC-JZ/OZ ARCTIC +UV: −60 °C fixed, flexible down to −40 °C, black UV sheath
An engineering guide to a cold- and UV-resistant PVC power, control and connecting cable for plant and machine building, HVAC, frozen-goods plants, cold stores and outdoor equipment in extreme climates.
1. Reading the designation
JZ = with GNYE and numbered cores (‘G’); OZ = without GNYE (‘x’). ARCTIC denotes the cold-resistant PVC compound system, +UV the UV-resistant black sheath, and −60 °C the minimum temperature for fixed installation.
Standard constructions, 2 × 0.5 to 4 G 70 mm².
Fixed installation.
Cold-flexible in motion.
Black RAL 9005 outdoor sheath.
2. Construction
Both the insulation and the sheath use cold-resistant PVC. That matters: a cold-resistant sheath over standard insulation still cracks at the cores when bent in the cold.
| Pos. | Element | Material / form | Engineering function |
|---|---|---|---|
| 1 | Conductor | Bare Cu, fine-wire, IEC 60228 cl. 5 | Flexibility, also at low temperature |
| 2 | Core insulation | Cold-resistant PVC, black | +70 °C continuous, +140 °C short-circuit |
| 3 | Core marking | White numerals per DIN VDE 0293 | Clear identification in multicore circuits |
| 4 | Protective conductor | GNYE core in JZ (‘G’) versions | OZ (‘x’) versions have none |
| 5 | Core assembly | Stranded in layers | Round geometry for gland sealing at low temperature |
| 6 | Outer sheath | Cold-resistant PVC, black RAL 9005, UV-resistant | Outdoor use; cold resistance to IEC 60811-1-4 |
3. Technical data
| Parameter | Value | Engineering note |
|---|---|---|
| Conductor material | Bare copper strand | |
| Conductor class | IEC 60228 class 5 | |
| Core insulation | PVC, cold resistant | |
| Core identification | Acc. to DIN VDE 0293: black cores with white numerals, with or without GNYE | |
| Stranding | Cores stranded in layers | |
| Outer sheath | PVC, cold resistant | UV-resistant black compound |
| Sheath colour | Black, RAL 9005 | |
| Rated voltage U0/U | 300/500 V | |
| Test voltage | 3 kV | |
| Conductor resistance | Acc. to IEC 60228 cl. 5 | |
| Insulation resistance | Min. 20 MΩ × km | |
| Current carrying capacity | Acc. to DIN VDE | Apply ambient, grouping and loaded-core factors |
| Min. bending radius fixed | 4 × d | |
| Min. bending radius moved | 15 × d | |
| Operating temp. fixed | −60 °C / +80 °C | Arctic fixed installation |
| Operating temp. moved | −40 °C / +70 °C | Cold-flexible down to −40 °C |
| Conductor temperature | +70 °C operation; +140 °C short-circuit | Note: 140 °C, lower than the 150 °C of standard JZ/OZ |
| Burning behaviour | Self-extinguishing and flame-retardant acc. to IEC 60332-1 | Single-cable test |
| Cold resistance | Increased, acc. to IEC 60811-1-4 | Cold bending, cold elongation and cold impact tests |
| Chemical resistance | Largely resistant to acids, bases and specified oils | |
| Standard | Similar to EN 50525-2-51 | |
| Compliance | RoHS; 2014/35/EU Low Voltage Directive (CE) |
4. Why standard PVC fails in the cold
PVC is flexible only because of its plasticiser. As temperature falls towards the compound’s glass-transition range, the polymer chains lose mobility and the material turns brittle: bending or impact then produces cracks through the sheath and insulation. Cold-resistant compounds use plasticiser systems that keep the material ductile to much lower temperatures. IEC 60811-1-4 verifies this with cold bending, cold elongation and cold impact tests.
| Variant | Fixed min. | Moved min. | Test basis |
|---|---|---|---|
| ÖPVC-JZ/OZ standard | −40 °C | −15 °C | Standard PVC |
| ÖPVC-JZ/OZ-Yö UL/CSA | −40 °C | −5 °C | Oil-resistant PVC |
| ÖPVC-JZ/OZ ARCTIC +UV | −60 °C | −40 °C | IEC 60811-1-4 |
5. Full dimension and weight tables
All 82 constructions are listed, grouped by cross-section. Bending radii are calculated from the nominal outer diameter.
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 2 x 0.5 | OZ (without GNYE) | 1005391 | 4.8 | 9.6 | 34.0 | 19 | 72 |
| 3 G 0.5 | JZ (with GNYE) | 1005392 | 5.1 | 14.4 | 41.0 | 20 | 76 |
| 3 x 0.5 | OZ (without GNYE) | 1005433 | 5.1 | 14.4 | 41.0 | 20 | 76 |
| 4 G 0.5 | JZ (with GNYE) | 1005434 | 5.5 | 19.2 | 51.0 | 22 | 82 |
| 4 x 0.5 | OZ (without GNYE) | 1005435 | 5.5 | 19.2 | 51.0 | 22 | 82 |
| 5 G 0.5 | JZ (with GNYE) | 1005436 | 6.3 | 24.0 | 63.0 | 25 | 94 |
| 5 x 0.5 | OZ (without GNYE) | 1005437 | 6.3 | 24.0 | 63.0 | 25 | 94 |
| 7 G 0.5 | JZ (with GNYE) | 1005438 | 6.8 | 34.0 | 79.0 | 27 | 102 |
| 7 x 0.5 | OZ (without GNYE) | 1005439 | 6.8 | 34.0 | 79.0 | 27 | 102 |
| 12 G 0.5 | JZ (with GNYE) | 1005440 | 9.1 | 58.0 | 137.0 | 36 | 136 |
| 14 G 0.5 | JZ (with GNYE) | 1005441 | 9.5 | 67.0 | 155.0 | 38 | 142 |
| 18 G 0.5 | JZ (with GNYE) | 1005442 | 10.8 | 86.0 | 198.0 | 43 | 162 |
| 25 G 0.5 | JZ (with GNYE) | 1005443 | 12.5 | 120.0 | 270.0 | 50 | 188 |
| 34 G 0.5 | JZ (with GNYE) | 1005444 | 14.9 | 163.0 | 378.0 | 60 | 224 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 2 x 0.75 | OZ (without GNYE) | 1005445 | 5.2 | 15.0 | 43.0 | 21 | 78 |
| 3 G 0.75 | JZ (with GNYE) | 1005446 | 5.5 | 22.0 | 52.0 | 22 | 82 |
| 3 x 0.75 | OZ (without GNYE) | 1005447 | 5.5 | 22.0 | 52.0 | 22 | 82 |
| 4 G 0.75 | JZ (with GNYE) | 1005448 | 6.2 | 29.0 | 65.0 | 25 | 93 |
| 4 x 0.75 | OZ (without GNYE) | 1005449 | 6.2 | 29.0 | 65.0 | 25 | 93 |
| 5 G 0.75 | JZ (with GNYE) | 1005450 | 6.8 | 36.0 | 81.0 | 27 | 102 |
| 5 x 0.75 | OZ (without GNYE) | 1005451 | 6.8 | 36.0 | 81.0 | 27 | 102 |
| 7 G 0.75 | JZ (with GNYE) | 1005452 | 7.6 | 50.0 | 102.0 | 30 | 114 |
| 7 x 0.75 | OZ (without GNYE) | 1005453 | 7.6 | 50.0 | 102.0 | 30 | 114 |
| 12 G 0.75 | JZ (with GNYE) | 1005454 | 9.9 | 86.0 | 179.0 | 40 | 148 |
| 18 G 0.75 | JZ (with GNYE) | 1005455 | 12.0 | 130.0 | 260.0 | 48 | 180 |
| 25 G 0.75 | JZ (with GNYE) | 1005456 | 13.9 | 180.0 | 354.0 | 56 | 208 |
| 34 G 0.75 | JZ (with GNYE) | 1005457 | 16.5 | 245.0 | 492.0 | 66 | 248 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 2 x 1 | OZ (without GNYE) | 1005458 | 5.5 | 19.0 | 50.0 | 22 | 82 |
| 3 G 1 | JZ (with GNYE) | 1005459 | 6.1 | 29.0 | 63.0 | 24 | 92 |
| 3 x 1 | OZ (without GNYE) | 1005460 | 6.1 | 29.0 | 63.0 | 24 | 92 |
| 4 G 1 | JZ (with GNYE) | 1005461 | 6.6 | 38.0 | 78.0 | 26 | 99 |
| 4 x 1 | OZ (without GNYE) | 1005462 | 6.6 | 38.0 | 78.0 | 26 | 99 |
| 5 G 1 | JZ (with GNYE) | 1005463 | 7.2 | 48.0 | 97.0 | 29 | 108 |
| 5 x 1 | OZ (without GNYE) | 1005464 | 7.2 | 48.0 | 97.0 | 29 | 108 |
| 7 G 1 | JZ (with GNYE) | 1005465 | 8.0 | 67.0 | 124.0 | 32 | 120 |
| 7 x 1 | OZ (without GNYE) | 1005466 | 8.0 | 67.0 | 124.0 | 32 | 120 |
| 12 G 1 | JZ (with GNYE) | 1005467 | 10.7 | 115.0 | 217.0 | 43 | 160 |
| 18 G 1 | JZ (with GNYE) | 1005468 | 12.7 | 173.0 | 315.0 | 51 | 190 |
| 25 G 1 | JZ (with GNYE) | 1005469 | 14.9 | 240.0 | 431.0 | 60 | 224 |
| 34 G 1 | JZ (with GNYE) | 1005470 | 17.7 | 326.0 | 598.0 | 71 | 266 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 2 x 1.5 | OZ (without GNYE) | 1005471 | 6.3 | 29.0 | 67.0 | 25 | 94 |
| 3 G 1.5 | JZ (with GNYE) | 1005472 | 6.7 | 43.0 | 84.0 | 27 | 100 |
| 3 x 1.5 | OZ (without GNYE) | 1005473 | 6.7 | 43.0 | 84.0 | 27 | 100 |
| 4 G 1.5 | JZ (with GNYE) | 1005474 | 7.5 | 58.0 | 106.0 | 30 | 112 |
| 4 x 1.5 | OZ (without GNYE) | 1005475 | 7.5 | 58.0 | 106.0 | 30 | 112 |
| 5 G 1.5 | JZ (with GNYE) | 1005476 | 8.2 | 72.0 | 131.0 | 33 | 123 |
| 5 x 1.5 | OZ (without GNYE) | 1005477 | 8.2 | 72.0 | 131.0 | 33 | 123 |
| 7 G 1.5 | JZ (with GNYE) | 1005478 | 9.1 | 101.0 | 169.0 | 36 | 136 |
| 7 x 1.5 | OZ (without GNYE) | 1005479 | 9.1 | 101.0 | 169.0 | 36 | 136 |
| 12 G 1.5 | JZ (with GNYE) | 1005480 | 12.1 | 173.0 | 295.0 | 48 | 182 |
| 18 G 1.5 | JZ (with GNYE) | 1005481 | 14.4 | 259.0 | 431.0 | 58 | 216 |
| 25 G 1.5 | JZ (with GNYE) | 1005482 | 16.8 | 360.0 | 591.0 | 67 | 252 |
| 34 G 1.5 | JZ (with GNYE) | 1005483 | 20.0 | 490.0 | 819.0 | 80 | 300 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 2 x 2.5 | OZ (without GNYE) | 1005484 | 7.7 | 48.0 | 103.0 | 31 | 116 |
| 3 G 2.5 | JZ (with GNYE) | 1005485 | 8.2 | 72.0 | 130.0 | 33 | 123 |
| 3 x 2.5 | OZ (without GNYE) | 1005486 | 8.2 | 72.0 | 130.0 | 33 | 123 |
| 4 G 2.5 | JZ (with GNYE) | 1005487 | 9.1 | 96.0 | 165.0 | 36 | 136 |
| 5 G 2.5 | JZ (with GNYE) | 1005488 | 10.0 | 120.0 | 206.0 | 40 | 150 |
| 7 G 2.5 | JZ (with GNYE) | 1005489 | 11.1 | 168.0 | 266.0 | 44 | 166 |
| 12 G 2.5 | JZ (with GNYE) | 1005490 | 15.0 | 288.0 | 468.0 | 60 | 225 |
| 18 G 2.5 | JZ (with GNYE) | 1005491 | 17.9 | 432.0 | 685.0 | 72 | 268 |
| 25 G 2.5 | JZ (with GNYE) | 1005492 | 20.9 | 600.0 | 941.0 | 84 | 314 |
| 34 G 2.5 | JZ (with GNYE) | 1005493 | 24.7 | 816.0 | 1,308.0 | 99 | 370 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 3 G 4 | JZ (with GNYE) | 1005495 | 9.7 | 115.0 | 195.0 | 39 | 146 |
| 4 G 4 | JZ (with GNYE) | 1005496 | 10.9 | 154.0 | 248.0 | 44 | 164 |
| 5 G 4 | JZ (with GNYE) | 1005497 | 12.1 | 192.0 | 310.0 | 48 | 182 |
| 7 G 4 | JZ (with GNYE) | 1005498 | 13.4 | 269.0 | 403.0 | 54 | 201 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 3 G 6 | JZ (with GNYE) | 1005500 | 11.5 | 173.0 | 283.0 | 46 | 172 |
| 4 G 6 | JZ (with GNYE) | 1005501 | 12.8 | 230.0 | 360.0 | 51 | 192 |
| 5 G 6 | JZ (with GNYE) | 1005502 | 14.3 | 288.0 | 451.0 | 57 | 214 |
| 7 G 6 | JZ (with GNYE) | 1005503 | 15.9 | 403.0 | 588.0 | 64 | 238 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 3 G 10 | JZ (with GNYE) | 1005505 | 14.7 | 288.0 | 456.0 | 59 | 220 |
| 4 G 10 | JZ (with GNYE) | 1005506 | 16.3 | 384.0 | 583.0 | 65 | 244 |
| 5 G 10 | JZ (with GNYE) | 1005507 | 18.2 | 480.0 | 731.0 | 73 | 273 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 4 G 16 | JZ (with GNYE) | 1005510 | 18.8 | 614.0 | 861.0 | 75 | 282 |
| 5 G 16 | JZ (with GNYE) | 1005511 | 21.2 | 768.0 | 1,080.0 | 85 | 318 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 4 G 25 | JZ (with GNYE) | 1005513 | 23.7 | 960.0 | 1,342.0 | 95 | 356 |
| 5 G 25 | JZ (with GNYE) | 1005514 | 26.6 | 1,200.0 | 1,683.0 | 106 | 399 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 4 G 35 | JZ (with GNYE) | 1005515 | 26.9 | 1,344.0 | 1,812.0 | 108 | 404 |
| 5 G 35 | JZ (with GNYE) | 1005516 | 30.2 | 1,680.0 | 2,270.0 | 121 | 453 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 4 G 50 | JZ (with GNYE) | 1005518 | 32.7 | 1,920.0 | 2,746.0 | 131 | 491 |
| Dimension n × mm² | Version | Reference item no. | Outer Ø mm | Cu index kg/km | Weight kg/km | Min. bend radius fixed (4 × d) mm | Min. bend radius moved (15 × d) mm |
|---|---|---|---|---|---|---|---|
| 4 G 70 | JZ (with GNYE) | 1005519 | 36.6 | 2,688.0 | 3,724.0 | 146 | 549 |
6. Application envelope
UV- and cold-resistant power, control and connecting cable in electrical facilities, e.g. plant and machine building, heating and air-conditioning technology, frozen-goods plants and cold stores. For fixed laying and flexible applications with free movement, without tensile stress and without forced guidance. Suitable for dry, humid and wet rooms and for outdoor use, but not for laying underground.
7. Comparison
| Type | Fixed range | Moved range | Outdoor | Test voltage | Sheath |
|---|---|---|---|---|---|
| ÖPVC-JZ/OZ (standard) | −40 / +80 °C | −15 / +70 °C | Indoor; outdoor only with UV protection | 4 kV | Grey RAL 7001 |
| ÖPVC-JZ/OZ ARCTIC +UV | −60 / +80 °C | −40 / +70 °C | Outdoor, UV-resistant | 3 kV | Black RAL 9005 |
| ÖPVC-JZ/OZ-Yö UL/CSA | −40 / +80 °C | −5 / +80 °C | Indoor; outdoor only with UV protection | 6 kV | Grey RAL 7001 |
| PUR control cable | ≈ −50 / +90 °C | ≈ −40 / +80 °C | Outdoor, abrasion-resistant | — | Various |
8. Design calculations
9. Certification and traceability
This cable is RoHS-conform and CE-conform to the 2014/35/EU Low Voltage Directive, with cold resistance verified to IEC 60811-1-4 and flame behaviour to IEC 60332-1. FeiChun Cable holds a complete export certification portfolio — including CE, UKCA, VDE, EAC, ATEX and IECEx — and every certificate supplied is checked against the exact type, voltage, factory and standard of the order.
Routine tests
Conductor resistance, 3 kV voltage test, insulation resistance, core numbering, dimensions and marking.
Type tests
Cold bending, cold elongation and cold impact to IEC 60811-1-4; IEC 60332-1 flame; UV weathering on request.
Delivery documents
Approved datasheet, test report per drum, batch number and length marking.
10. FAQ
How low can it go?
−60 °C in fixed installation, and it remains flexible for movement down to −40 °C.
Why is the sheath black?
Carbon-black pigmented RAL 9005 compound absorbs UV and protects the polymer from photo-degradation in outdoor service.
Can it be installed at −40 °C?
It is rated for movement down to −40 °C. Good practice is still to keep drums above 0 °C before pulling and avoid impact during handling in extreme cold.
Can it be buried?
No. Outdoor use is permitted, but not laying underground.
Why only 140 °C short-circuit?
The cold-resistant PVC compound uses a plasticiser system optimised for low temperature; its short-circuit limit is 140 °C instead of 150 °C.
Typical applications?
Plant and machine building, heating and air-conditioning, frozen-goods plants and cold stores, outdoor equipment in cold climates such as Russia, Kazakhstan, Mongolia and northern Canada.
Technical and project enquiries: [email protected]
+86 13855123218