An engineering guide to the multi-approved control cable: HAR 300/500 V at 70 °C and UL/CSA 600 V at 90 °C, numbered black cores, AWG equivalents and a special oil-resistant grey PVC sheath for wet rooms and water-oil mixtures.

HAR · EN 50525-2-51UL Style 2517/2587CSA C22.2 No. 210.2300/500 V · 600 V70 °C · 90 °CVW-1 · FT1UL 1581 T50.182 oilRoHS · CE
Document FC-ART-MNORM-2026-1705Updated: 20 September 2026FeiChun Cable / 飞纯电缆
Engineer’s summary: MULTINORM reduces stock and documentation for machine builders exporting to both Europe and North America: up to 2.5 mm² the cable carries HAR, UL and CSA; from 4 mm² it is the 2-NORM UL/CSA version. Always apply the voltage and temperature rating of the code you design to.

1. Reading the designation

H05VV5-F = harmonised 300/500 V, PVC insulation, oil-resistant PVC sheath, fine-wire conductor. MULTINORM = HAR + UL + CSA (0.5–2.5 mm²). 2-NORM (H)05VV5-F = UL + CSA (4–120 mm²). ‘G’ = with GNYE; ‘x’ = without.

72

Standard constructions, 2 × 0.5 to 4 G 120 mm² (AWG 21 to 4/0).

3

Approvals: HAR, UL, CSA.

600 V

UL/CSA rating.

90 °C

UL/CSA temperature rating.

2. Construction

Cross-section MULTINORM H05VV5-F 7 G · HAR/UL/CSA, oil-resistant PVCEngineering-drawing style · functional, not to scale · final dimensions per approved order drawingGNYE123456Ø d = 5.8 … 54.2 mm (see tables) (see tables)1Bare Cu strand, IEC 60228 class 52PVC core insulation, black3White numerals (DIN VDE 0293)4GNYE protective conductor (from 3 cores)5Cores stranded in layers6Grey oil-resistant PVC sheath RAL 7001 (EN 50363-4-1)DocumentRevisionProjectionFC-ART-MNORM-2026-1705A · 2026-091st angle
Figure 1: Construction of the 7 G version; callouts match the Pos. column of the materials table.
Materials table (Pos. = callout numbers in Figure 1)
Pos.ElementMaterial / formEngineering function
1ConductorBare Cu, fine-wire, IEC 60228 cl. 5Flexibility; AWG equivalents given for each size
2Core insulationPVC, blackHAR 70 °C; UL/CSA 90 °C rating
3Core markingWhite numerals per DIN VDE 0293Clear identification in multicore circuits
4Protective conductorGNYE core (‘G’)2-core ‘x’ versions without
5Core assemblyStranded in layersRound geometry for gland sealing
6Outer sheathSpecial oil-resistant PVC, grey RAL 7001EN 50363-4-1 and UL 1581 T50.182; VW-1, CSA FT1

3. Technical data

Technical data (complete)
ParameterValueEngineering note
Conductor materialBare copper strand
Conductor classIEC 60228 class 5
Core insulationPVC
Core identificationAcc. to DIN VDE 0293: black cores with white numerals; G = with GNYE
StrandingCores stranded in layers
Outer sheathPVC (special oil-resistant compound)EN 50363-4-1 & UL 1581 T50.182
Sheath colourGrey, RAL 7001
Rated voltageHAR: U0/U 300/500 V; UL/CSA: 600 VUL/CSA 600 V allows parallel laying with other 600 V cables
Test voltage3 kV
Conductor resistanceAcc. to IEC 60228 cl. 5
Insulation resistanceMin. 20 MΩ × km
Current carrying capacityAcc. to DIN VDE (technical guideline)For NEC/NFPA 79 installations use the UL basis
Min. bending radius fixed4 × d
Min. bending radius moved12.5 × d
Operating temp. fixedHAR: −40 °C / +70 °C; UL/CSA: −40 °C / +90 °CRating depends on the approval applied
Operating temp. movedHAR: −5 °C / +70 °C; UL/CSA: −5 °C / +90 °C
Conductor temperature+70 °C operation; +150 °C short-circuitIEC/HAR basis
Burning behaviourSelf-extinguishing and flame-retardant acc. to IEC 60332-1; VW-1; CSA FT1
StandardEN 50525-2-51 / VDE 0285-525-2-51; UL Style 2517/2587; CSA C22.2 No. 210.2-M90 AWM I A/B II A/B
ApprovalsHAR: 300/500 V – 70 °C · UL/CSA: 600 V – 90 °CUp to 2.5 mm²: MULTINORM H05VV5-F HAR/UL/CSA; from 4 mm²: 2-NORM (H)05VV5-F UL/CSA
ComplianceRoHS; 2014/35/EU Low Voltage Directive (CE); LABS-/silicone-free during production

4. Dual ratings explained

Which rating applies
Design basisVoltageTemperatureFlame testSize range
IEC / EN (HAR)300/500 V70 °CIEC 60332-10.5–2.5 mm²
UL (AWM Style 2517/2587)600 V90 °CVW-10.5–120 mm²
CSA (C22.2 No. 210.2 AWM)600 V90 °CFT10.5–120 mm²

5. Full dimension and weight tables

All 72 constructions are listed, grouped by cross-section with AWG equivalents. Bending radii are calculated from the nominal outer diameter (4 × d fixed, 12.5 × d moved).

Cross-section 0.5 mm² / AWG 21 · MULTINORM · HAR 300/500 V · UL/CSA 600 V · 10 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
2 x 0.5 (AWG 21)MULTINORM HAR/UL/CSA10000135.89.646.02372
3 G 0.5 (AWG 21)MULTINORM HAR/UL/CSA10000166.214.453.02578
4 G 0.5 (AWG 21)MULTINORM HAR/UL/CSA10000216.719.263.02784
5 G 0.5 (AWG 21)MULTINORM HAR/UL/CSA10000277.524.077.03094
7 G 0.5 (AWG 21)MULTINORM HAR/UL/CSA10000329.333.6111.037116
12 G 0.5 (AWG 21)MULTINORM HAR/UL/CSA100000510.957.6163.044136
18 G 0.5 (AWG 21)MULTINORM HAR/UL/CSA100005613.086.4215.052162
25 G 0.5 (AWG 21)MULTINORM HAR/UL/CSA100001015.2120.0348.061190
34 G 0.5 (AWG 21)MULTINORM HAR/UL/CSA100001417.7163.0508.071221
41 G 0.5 (AWG 21)MULTINORM HAR/UL/CSA100352119.5197.0570.078244
Cross-section 0.75 mm² / AWG 19 · MULTINORM · HAR 300/500 V · UL/CSA 600 V · 11 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
2 x 0.75 (AWG 19)MULTINORM HAR/UL/CSA10000576.214.452.02578
3 G 0.75 (AWG 19)MULTINORM HAR/UL/CSA10000176.621.664.02682
4 G 0.75 (AWG 19)MULTINORM HAR/UL/CSA10000227.228.878.02990
5 G 0.75 (AWG 19)MULTINORM HAR/UL/CSA10000288.136.098.032101
7 G 0.75 (AWG 19)MULTINORM HAR/UL/CSA100018510.050.4140.040125
8 G 0.75 (AWG 19)MULTINORM HAR/UL/CSA100437310.657.6178.042132
12 G 0.75 (AWG 19)MULTINORM HAR/UL/CSA100000611.986.4210.048149
18 G 0.75 (AWG 19)MULTINORM HAR/UL/CSA100011314.1130.0306.056176
25 G 0.75 (AWG 19)MULTINORM HAR/UL/CSA100001116.6180.0431.066208
34 G 0.75 (AWG 19)MULTINORM HAR/UL/CSA100352419.3245.0567.077241
41 G 0.75 (AWG 19)MULTINORM HAR/UL/CSA100305921.2296.0680.085265
Cross-section 1 mm² / AWG 18 · MULTINORM · HAR 300/500 V · UL/CSA 600 V · 11 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
2 x 1 (AWG 18)MULTINORM HAR/UL/CSA10028306.519.260.02681
3 G 1 (AWG 18)MULTINORM HAR/UL/CSA10000186.928.875.02886
4 G 1 (AWG 18)MULTINORM HAR/UL/CSA10000237.738.492.03196
5 G 1 (AWG 18)MULTINORM HAR/UL/CSA10000298.548.0116.034106
7 G 1 (AWG 18)MULTINORM HAR/UL/CSA100003310.767.2166.043134
12 G 1 (AWG 18)MULTINORM HAR/UL/CSA100157112.6115.0256.050158
18 G 1 (AWG 18)MULTINORM HAR/UL/CSA100000815.1173.0359.060189
25 G 1 (AWG 18)MULTINORM HAR/UL/CSA100229517.6240.0527.070220
34 G 1 (AWG 18)MULTINORM HAR/UL/CSA100001520.5326.0694.082256
41 G 1 (AWG 18)MULTINORM HAR/UL/CSA100283522.6394.0813.090282
50 G 1 (AWG 18)MULTINORM HAR/UL/CSA100189524.6480.01,005.098308
Cross-section 1.5 mm² / AWG 16 · MULTINORM · HAR 300/500 V · UL/CSA 600 V · 10 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
2 x 1.5 (AWG 16)MULTINORM HAR/UL/CSA10000587.728.877.03196
3 G 1.5 (AWG 16)MULTINORM HAR/UL/CSA10000198.243.297.033102
4 G 1.5 (AWG 16)MULTINORM HAR/UL/CSA10000249.157.6128.036114
5 G 1.5 (AWG 16)MULTINORM HAR/UL/CSA100003010.072.0149.040125
7 G 1.5 (AWG 16)MULTINORM HAR/UL/CSA100003412.6101.0216.050158
12 G 1.5 (AWG 16)MULTINORM HAR/UL/CSA100000715.0173.0324.060188
18 G 1.5 (AWG 16)MULTINORM HAR/UL/CSA100157017.9259.0485.072224
25 G 1.5 (AWG 16)MULTINORM HAR/UL/CSA100001220.9360.0671.084261
34 G 1.5 (AWG 16)MULTINORM HAR/UL/CSA100352924.3490.0881.097304
41 G 1.5 (AWG 16)MULTINORM HAR/UL/CSA100353026.9591.01,085.0108336
Cross-section 2.5 mm² / AWG 14 · MULTINORM · HAR 300/500 V · UL/CSA 600 V · 8 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
2 x 2.5 (AWG 14)MULTINORM HAR/UL/CSA10035329.148.0110.036114
3 G 2.5 (AWG 14)MULTINORM HAR/UL/CSA10000209.672.0154.038120
4 G 2.5 (AWG 14)MULTINORM HAR/UL/CSA100002510.796.0198.043134
5 G 2.5 (AWG 14)MULTINORM HAR/UL/CSA100003112.0120.0238.048150
7 G 2.5 (AWG 14)MULTINORM HAR/UL/CSA100003515.0168.0345.060188
12 G 2.5 (AWG 14)MULTINORM HAR/UL/CSA100157217.8288.0531.071222
18 G 2.5 (AWG 14)MULTINORM HAR/UL/CSA100199721.3432.0781.085266
25 G 2.5 (AWG 14)MULTINORM HAR/UL/CSA100314225.0600.01,070.0100312
Cross-section 4 mm² / AWG 12 · 2-NORM · UL/CSA 600 V · 4 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
3 G 4 (AWG 12)2-NORM (H)05VV5-F UL/CSA100312011.0115.0232.044138
4 G 4 (AWG 12)2-NORM (H)05VV5-F UL/CSA100184012.5154.0298.050156
5 G 4 (AWG 12)2-NORM (H)05VV5-F UL/CSA100164713.3192.0358.053166
7 G 4 (AWG 12)2-NORM (H)05VV5-F UL/CSA100308415.0269.0460.060188
Cross-section 6 mm² / AWG 10 · 2-NORM · UL/CSA 600 V · 5 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
2 G 6 (AWG 10)2-NORM (H)05VV5-F UL/CSA100588910.6115.0200.042132
3 G 6 (AWG 10)2-NORM (H)05VV5-F UL/CSA100356912.9173.0360.052161
4 G 6 (AWG 10)2-NORM (H)05VV5-F UL/CSA100241014.2231.0402.057178
5 G 6 (AWG 10)2-NORM (H)05VV5-F UL/CSA100162715.9288.0484.064199
7 G 6 (AWG 10)2-NORM (H)05VV5-F UL/CSA100357017.6403.0640.070220
Cross-section 10 mm² / AWG 8 · 2-NORM · UL/CSA 600 V · 3 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
4 G 10 (AWG 8)2-NORM (H)05VV5-F UL/CSA100171517.4384.0653.070217
5 G 10 (AWG 8)2-NORM (H)05VV5-F UL/CSA100187219.1480.0709.076239
7 G 10 (AWG 8)2-NORM (H)05VV5-F UL/CSA100319621.0672.0917.084262
Cross-section 16 mm² / AWG 6 · 2-NORM · UL/CSA 600 V · 2 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
4 G 16 (AWG 6)2-NORM (H)05VV5-F UL/CSA100187321.9615.01,045.088274
5 G 16 (AWG 6)2-NORM (H)05VV5-F UL/CSA100357324.3768.01,260.097304
Cross-section 25 mm² / AWG 4 · 2-NORM · UL/CSA 600 V · 2 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
4 G 25 (AWG 4)2-NORM (H)05VV5-F UL/CSA100189325.6960.01,501.0102320
5 G 25 (AWG 4)2-NORM (H)05VV5-F UL/CSA100357528.81,200.01,853.0115360
Cross-section 35 mm² / AWG 2 · 2-NORM · UL/CSA 600 V · 2 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
4 G 35 (AWG 2)2-NORM (H)05VV5-F UL/CSA100189229.51,344.02,123.0118369
5 G 35 (AWG 2)2-NORM (H)05VV5-F UL/CSA100357732.41,680.02,612.0130405
Cross-section 50 mm² / AWG 1 · 2-NORM · UL/CSA 600 V · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
4 G 50 (AWG 1)2-NORM (H)05VV5-F UL/CSA100290335.71,920.02,898.0143446
Cross-section 70 mm² / AWG 2/0 · 2-NORM · UL/CSA 600 V · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
4 G 70 (AWG 2/0)2-NORM (H)05VV5-F UL/CSA100357843.02,688.04,011.0172538
Cross-section 95 mm² / AWG 3/0 · 2-NORM · UL/CSA 600 V · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
4 G 95 (AWG 3/0)2-NORM (H)05VV5-F UL/CSA100357947.23,648.05,430.0189590
Cross-section 120 mm² / AWG 4/0 · 2-NORM · UL/CSA 600 V · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 4 × d mmMin. bend moved 12.5 × d mm
4 G 120 (AWG 4/0)2-NORM (H)05VV5-F UL/CSA100274854.24,608.06,290.0217678

6. Application envelope

Power, control and connecting cable in electrical facilities, for fixed laying and occasional free movement without tensile stress and without forced guidance. Suitable for dry, humid and wet rooms, including water-oil mixtures. Outdoor use only with UV protection; not for burial.

Application envelope of MULTINORM H05VV5-F HAR/UL/CSA ✔ Machine tools, coolant Water-oil mixtures (coolant emulsions) ✔ Machines for EU and North America Free movement ≥ 12.5 × d, above −5 °C ✘ Not designed for • Drag chains / forced guidance• Tensile load, reels, festoons• Direct burial• Outdoors without UV protection• Flexing below −5 °C / EMC circuits For EMC choose a screened type;for chains a PUR/TPE chain cable. Suitable for dry, humid and wet rooms. One cable for three approvals: HAR 300/500 V 70 °C and UL/CSA 600 V 90 °C.
Figure 2: Permitted duties and exclusions.

7. Comparison

MULTINORM compared with related cables
TypeApprovalsVoltageTemperatureFlameTypical use
H05VV5-F HARHAR only300/500 V70 °CIEC 60332-1EU machines
MULTINORM H05VV5-F HAR/UL/CSAHAR + UL + CSA300/500 V · 600 V70 °C HAR · 90 °C UL/CSAIEC 60332-1, VW-1, FT1One cable for EU and North America
ÖPVC-JZ/OZ-Yö UL/CSAUL 2570 / CSA AWM450/750 V · 1 000 V80 °CIEC 60332-3-24 Cat. C, FT1Higher voltage, bunched fire rating
UL TC-ERUL tray cable600 V90 °CUL 1685 / FT4NEC field wiring

8. Design calculations

IEC installation: DIN VDE base rating × f(ambient) × f(grouping) × f(loaded cores), 70 °C basis North American machinery: NFPA 79 / UL ampacity tables, 90 °C cable rating (terminal ratings may limit to 60/75 °C) Short-circuit (PVC 70 → 150 °C, Cu): I_k ≈ 115 × S / √t e.g. 4 G 120, t = 0.5 s → ≈ 19.5 kA Voltage drop: ΔU = √3 × I × L × (R cosφ + X sinφ) Bending: fixed R ≥ 4 × d · moved R ≥ 12.5 × d e.g. 25 G 1.5 (d = 20.9 mm): 84 mm / 261 mm

9. Certification and traceability

This cable carries HAR (300/500 V, 70 °C) to EN 50525-2-51 / VDE 0285-525-2-51 up to 2.5 mm², and UL/CSA (600 V, 90 °C) to UL Style 2517/2587 and CSA C22.2 No. 210.2-M90 across the range. It is RoHS-conform, CE-conform to the 2014/35/EU Low Voltage Directive and LABS-/silicone-free during production. FeiChun Cable holds a complete export certification portfolio — including CE, UKCA, VDE, EAC, ATEX and IECEx — and every certificate supplied is checked against the exact type, voltage, factory and standard of the order.

Routine tests

Conductor resistance, 3 kV voltage test, insulation resistance, core numbering, dimensions and marking.

Type tests

IEC 60332-1, VW-1, CSA FT1; oil immersion to EN 50363-4-1 and UL 1581 T50.182.

Delivery documents

Approved datasheet, test report per drum, HAR/UL/CSA marking, batch number and length marking.

10. FAQ

What does MULTINORM mean?

One cable carrying three approvals — HAR, UL and CSA — so a machine builder stocks a single control cable for European and North American machines.

Why is it called 2-NORM from 4 mm²?

From 4 mm² the harmonised HAR scope ends; these sizes carry UL and CSA approvals and follow the H05VV5-F construction, hence (H)05VV5-F UL/CSA.

Why does the temperature differ?

HAR rates the cable at 70 °C, UL/CSA at 90 °C. Apply the rating of the code you are designing to.

What does parallel laying at 600 V mean?

In North American installations, cables may share a raceway only if their voltage ratings cover the highest voltage present. The 600 V rating allows it next to other 600 V cables.

What are VW-1 and FT1?

UL VW-1 and CSA FT1 are vertical flame tests on a single cable, the North American counterparts of IEC 60332-1.

Suitable for coolant?

Yes: wet rooms including water-oil mixtures, with an oil-resistant sheath to EN 50363-4-1 and UL 1581 T50.182.

FeiChun Cable / 飞纯电缆
Technical and project enquiries: [email protected]
Manufacturing in China, export support
+86 13855123218
FEICHUN CABLE

One control cable, three approvals: HAR, UL and CSA

For machine builders exporting to Europe and North America.

[email protected]

+86 13855123218

Document FC-ART-MNORM-2026-1705. Final values are governed by the approved datasheet, order drawing, batch test reports and certificate scope.