H05VVC4V5-K HAR: harmonised, screened and oil-resistant control cable

An engineering guide to the screened member of the harmonised PVC family: numbered black cores, a PVC inner sheath, a tinned copper braid of approx. 85 % coverage and a special oil-resistant grey sheath for wet rooms and water-oil mixtures.

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
H05VVC4V5-K HAR screened oil-resistant control cable | FeiChun Cable
FEICHUN CABLE · HARMONISED SCREENED OIL-RESISTANT CONTROL CABLE

H05VVC4V5-K HAR: harmonised, screened and oil-resistant control cable

An engineering guide to the screened member of the harmonised PVC family: numbered black cores, a PVC inner sheath, a tinned copper braid of approx. 85 % coverage and a special oil-resistant grey sheath for wet rooms and water-oil mixtures.

EN 50525-2-51VDE 0285-525-2-51HAREN 50363-4-1 sheathCu braid ≈85 %IEC 60332-1300/500 VTest voltage 3 kVRoHS · CE
Document FC-ART-H05VVC4-2026-DA0BUpdated: 20 September 2026FeiChun Cable / 飞纯电缆
Engineer’s summary: choose H05VVC4V5-K when a European specification requires a HAR-marked, EMC-screened control cable in an oily or wet environment. Limits: +70 °C maximum, no flexing below −5 °C, no burial, outdoor only with UV protection.

1. Reading the designation

Harmonised code: H harmonised, 05 300/500 V, V PVC insulation, V PVC inner sheath, C4 copper braid screen, V5 oil-resistant PVC sheath, K fine-wire conductor for fixed installation.

34

Standard constructions, 3 G 0.5 to 12 G 2.5 mm².

HAR

European harmonised approval.

≈85 %

Braid coverage.

Oil + water

Suitable for water-oil mixtures.

2. Construction

The inner sheath cushions the cores and keeps the braid round so its coverage stays uniform; the oil-resistant outer sheath protects the braid from coolant emulsions.

Cross-section H05VVC4V5-K 7 G · HAR, inner sheath, Cu braid, oil-resistant sheathEngineering-drawing style · functional, not to scale · final dimensions per approved order drawingGNYE123456Ø d = 8.0 … 32.4 mm (min – max per size) (see tables)1Bare Cu strand, IEC 60228 class 52PVC core insulation, black3White numerals (DIN VDE 0293)4GNYE protective conductor (G)5PVC inner sheath6Tinned Cu braid, approx. 85 %7Grey oil-resistant PVC sheath RAL 7001DocumentRevisionProjectionFC-ART-H05VVC4-2026-DA0BA · 2026-091st angle
Figure 1: Construction of the 7 G version; callouts match the Pos. column of the materials table.
Materials table (Pos. = callout numbers in Figure 1)
Pos.ElementMaterial / formEngineering function
1ConductorBare Cu, fine-wire, IEC 60228 cl. 5Flexibility for installation and free movement
2Core insulationPVC, black+70 °C continuous, +150 °C short-circuit
3Core markingWhite numerals per DIN VDE 0293Clear identification in multicore circuits
4Protective conductorGNYE core (‘G’)PE continuity
5Inner sheathPVCAdditional mechanical protection; keeps braid round
6Overall screenTinned Cu braid, approx. 85 % optical coverageEMC-compliant screening
7Outer sheathSpecial oil-resistant PVC, grey RAL 7001EN 50363-4-1; water-oil mixtures; acids and bases largely resisted

3. Technical data

Technical data (complete)
ParameterValueEngineering note
Conductor materialBare copper strand
Conductor classIEC 60228 class 5
Core insulationPVC
Core identificationAcc. to DIN VDE 0293: black cores with white numerals; G = with GNYE
StrandingCores stranded in layers
Inner sheathPVCAdditional mechanical protection
Overall screenTinned copper braid, optical coverage approx. 85 %EMC-compliant
Outer sheathPVC (special oil-resistant compound)EN 50363-4-1
Sheath colourGrey, RAL 7001
Rated voltage U0/U300/500 V
Test voltage3 kV
Conductor resistanceAcc. to IEC 60228 cl. 5
Insulation resistanceMin. 20 MΩ × km
Current carrying capacityAcc. to DIN VDE (technical guideline)
Min. bending radius fixed6 × d
Min. bending radius moved12.5 × d
Operating temp. fixed−40 °C / +70 °C+70 °C maximum (harmonised type)
Operating temp. moved−5 °C / +70 °C
Conductor temperature+70 °C operation; +150 °C short-circuit
Burning behaviourSelf-extinguishing and flame-retardant acc. to IEC 60332-1
StandardEN 50525-2-51 / VDE 0285-525-2-51Harmonised standard
ApprovalHAR
ComplianceRoHS; 2014/35/EU Low Voltage Directive (CE); LABS-/silicone-free during production

4. EMC and termination

1. Bond the braid 360° with EMC glands; avoid pigtails. 2. Size glands for the full d_min … d_max range of the harmonised standard. 3. Segregate screened control cables from unscreened power cables. 4. For ground-loop-sensitive analogue signals, follow the equipment manufacturer.

5. Full dimension and weight tables

All 34 constructions are listed, grouped by cross-section. Outer diameters are the min–max range of the harmonised standard; bending radii use the maximum diameter.

Source data to verify before publication: 4 G 0.5 shows Cu index 58.0 kg/km, higher than 4 G 0.75 (55.0); 34 G 1.5 shows 754.0, out of sequence with 25 G 1.5 (448.0). Shown as received.
Cross-section 0.5 mm² · 300/500 V · HAR · screened · 5 constructions
Dimension n × mm²VersionReference item no.Outer Ø min – max mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × dmax mmMin. bend moved 12.5 × dmax mm
3 G 0.5G (with GNYE)10034578.0 – 10.036.0109.060125
4 G 0.5G (with GNYE)10002298.5 – 10.758.0126.064134
5 G 0.5G (with GNYE)10034589.3 – 11.663.0156.070145
7 G 0.5G (with GNYE)100024510.8 – 13.570.0192.081169
12 G 0.5G (with GNYE)100320213.3 – 16.5105.0280.099206
Cross-section 0.75 mm² · 300/500 V · HAR · screened · 8 constructions
Dimension n × mm²VersionReference item no.Outer Ø min – max mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × dmax mmMin. bend moved 12.5 × dmax mm
3 G 0.75G (with GNYE)10022998.3 – 10.448.0130.062130
4 G 0.75G (with GNYE)10002319.1 – 11.355.0164.068141
5 G 0.75G (with GNYE)10002419.7 – 12.166.0189.073151
7 G 0.75G (with GNYE)100024611.5 – 14.385.0247.086179
12 G 0.75G (with GNYE)100020813.9 – 17.2135.0327.0103215
18 G 0.75G (with GNYE)100021416.2 – 19.9190.0470.0119249
25 G 0.75G (with GNYE)100021718.7 – 23.0275.0643.0138288
34 G 0.75G (with GNYE)100022221.4 – 26.2340.0821.0157328
Cross-section 1 mm² · 300/500 V · HAR · screened · 8 constructions
Dimension n × mm²VersionReference item no.Outer Ø min – max mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × dmax mmMin. bend moved 12.5 × dmax mm
3 G 1G (with GNYE)10002268.8 – 11.059.0143.066138
4 G 1G (with GNYE)10002339.4 – 11.770.0175.070146
5 G 1G (with GNYE)100024210.3 – 12.884.0205.077160
7 G 1G (with GNYE)100024712.2 – 15.1106.0264.091189
12 G 1G (with GNYE)100020914.7 – 18.1174.0420.0109226
18 G 1G (with GNYE)100021216.9 – 20.8240.0561.0125260
25 G 1G (with GNYE)100022019.8 – 24.2332.0792.0145302
34 G 1G (with GNYE)100022322.6 – 27.7420.0996.0166346
Cross-section 1.5 mm² · 300/500 V · HAR · screened · 8 constructions
Dimension n × mm²VersionReference item no.Outer Ø min – max mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × dmax mmMin. bend moved 12.5 × dmax mm
3 G 1.5G (with GNYE)10002279.7 – 12.175.0176.073151
4 G 1.5G (with GNYE)100023410.7 – 13.290.0207.079165
5 G 1.5G (with GNYE)100024311.8 – 14.7108.0268.088184
7 G 1.5G (with GNYE)100024814.1 – 17.4157.0418.0104217
12 G 1.5G (with GNYE)100021016.7 – 20.5240.0500.0123256
18 G 1.5G (with GNYE)100021319.6 – 24.1355.0707.0145301
25 G 1.5G (with GNYE)100021822.9 – 28.0448.0950.0168350
34 G 1.5G (with GNYE)100022426.5 – 32.4754.01,204.0194405
Cross-section 2.5 mm² · 300/500 V · HAR · screened · 5 constructions
Dimension n × mm²VersionReference item no.Outer Ø min – max mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × dmax mmMin. bend moved 12.5 × dmax mm
3 G 2.5G (with GNYE)100022811.3 – 14.0104.0240.084175
4 G 2.5G (with GNYE)100023512.6 – 15.5163.0323.093194
5 G 2.5G (with GNYE)100024413.9 – 17.2175.0364.0103215
7 G 2.5G (with GNYE)100024916.5 – 20.3235.0439.0122254
12 G 2.5G (with GNYE)100021119.9 – 24.4375.0744.0146305

6. Application envelope

Power, control and connecting cable in electrical facilities, for interference-free data and signal transmission, in fixed laying and flexible applications with free movement, without tensile stress and without forced guidance. Suitable for dry, humid and wet rooms, including water-oil mixtures. Outdoor use only with UV protection; not for burial.

Application envelope of H05VVC4V5-K HAR ✔ Drive to motor (VSD) 360° braid bonding at both ends ✔ Machine tools, coolant Free movement ≥ 12.5 × d, above −5 °C ✘ Not designed for • Drag chains / forced guidance• Tensile load, reels, festoons• Direct burial• Outdoors without UV protection• Pigtail braid terminations Use a PUR/TPE screened chain cablefor drag chains. Suitable for dry, humid and wet rooms. Suitable for dry, humid and wet rooms; the braid works only if terminated 360°.
Figure 2: Permitted duties and exclusions.

7. Comparison

H05VVC4V5-K compared with related cables
TypeScreenSheathApprovalBending fixed / movedTypical use
H05VV5-F HARNoneOil-resistant PVCHAR4 × d / 12.5 × dUnscreened harmonised control
H05VVC4V5-K HARTinned Cu braid ≈85 %PVC inner + oil-resistant PVC outerHAR6 × d / 12.5 × dScreened harmonised control, coolant areas
ÖPVC-JZ/OZ-YCYTinned Cu braid ≈85 %PVC inner + transparent outerSimilar to EN 50525-2-516 × d / 15 × dScreened control, non-HAR
ÖPVC-JZ/OZ-CYö UL/CSACu braid 85 % ± 5 %Oil-resistant PVC, no inner sheathUL/CSA6 × d / 20 × dNorth American export

8. Design calculations

Current rating: DIN VDE base value × f(ambient) × f(grouping) × f(loaded cores) Short-circuit (PVC 70 → 150 °C, Cu): I_k ≈ 115 × S / √t e.g. 7 G 2.5, t = 0.2 s → ≈ 0.64 kA Voltage drop: ΔU = √3 × I × L × (R cosφ + X sinφ) Bending (use d_max): fixed R ≥ 6 × d · moved R ≥ 12.5 × d e.g. 25 G 1.5 (d_max = 28.0 mm): 168 mm / 350 mm

9. Certification and traceability

This cable carries the HAR approval to EN 50525-2-51 / VDE 0285-525-2-51, is RoHS-conform, CE-conform to the 2014/35/EU Low Voltage Directive and LABS-/silicone-free during production. FeiChun Cable holds a complete export certification portfolio — including CE, UKCA, VDE, EAC, ATEX and IECEx — and every certificate supplied is checked against the exact type, voltage, factory and standard of the order.

Routine tests

Conductor resistance, 3 kV voltage test, insulation resistance, braid continuity, dimensions within harmonised limits, marking.

Type tests

IEC 60332-1 flame, oil immersion of the sheath (EN 50363-4-1), ageing, cold behaviour.

Delivery documents

Approved datasheet, test report per drum, HAR marking, batch number and length marking.

10. FAQ

What does H05VVC4V5-K mean?

H = harmonised; 05 = 300/500 V; V = PVC insulation; V = PVC inner sheath; C4 = copper braid screen; V5 = oil-resistant PVC sheath; K = fine-wire conductor for fixed installation (class 5).

Why ‘K’ and not ‘F’?

In the harmonised code, K denotes a flexible conductor intended mainly for fixed installation; the cable still allows free movement without tension.

Is it suitable for coolant areas?

Yes. The special oil-resistant sheath is suitable for wet rooms including water-oil mixtures.

Why diameter ranges?

EN 50525-2-51 specifies min–max limits. Choose EMC glands whose clamping range covers the full range; bending radii here use d_max.

How should the braid be terminated?

360° with EMC glands at both ends for drive and switching noise; avoid pigtails.

How many cores?

Up to 34 cores in 0.75–1.5 mm², 12 cores in 0.5 and 2.5 mm².

FeiChun Cable / 飞纯电缆
Technical and project enquiries: [email protected]
Manufacturing in China, export support
+86 13855123218
FEICHUN CABLE

Harmonised, screened and oil-resistant — one control cable for European machines

For machine tools, control panels and industrial equipment.

[email protected]

+86 13855123218

Document FC-ART-H05VVC4-2026-DA0B. Final values are governed by the approved datasheet, order drawing, batch test reports and certificate scope.

Previous Article

H05VV5-F HAR: harmonised oil-resistant PVC control cable with numbered cores

Next Article

MULTINORM H05VV5-F HAR/UL/CSA: one oil-resistant control cable for Europe and North America

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注