2-NORM-CY 1 000 V UL/CSA: 90 °C EMC-screened control cable in grey and black +UV

An engineering guide to a dual-standard control cable rated UL/CSA 1 000 V and VDE 300/500 V: 90 °C PVC to UL 1581, numbered cores, a tinned copper braid of approx. 85 % coverage, TM54 oil resistance, bunched-cable fire performance and a black UV-resistant version for outdoor use.

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
2-NORM-CY 1 000 V UL/CSA screened control cable | FeiChun Cable
FEICHUN CABLE · 1 000 V UL/CSA SCREENED CONTROL CABLE

2-NORM-CY 1 000 V UL/CSA: 90 °C EMC-screened control cable in grey and black +UV

An engineering guide to a dual-standard control cable rated UL/CSA 1 000 V and VDE 300/500 V: 90 °C PVC to UL 1581, numbered cores, a tinned copper braid of approx. 85 % coverage, TM54 oil resistance, bunched-cable fire performance and a black UV-resistant version for outdoor use.

cURus 90 °C · 1 000 VVDE-Reg.VDE 300/500 V6 kV testCu braid ≈85 %IEC 60332-3-24 Cat. CVW-1 · FT1 · F2TM54 oilGrey RAL 7001 · black RAL 9005 UV
Document FC-ART-2NCY-2026-D920Updated: 20 September 2026FeiChun Cable / 飞纯电缆
Engineer’s summary: 2-NORM-CY adds an EMC braid to the 2-NORM 1 000 V concept: a screened control cable that may share trays and raceways with 1 000 V power cables in North America, runs at 90 °C and passes bunched-cable fire tests. Only the black +UV type may be installed outdoors; neither type is for burial, drag chains or flexing below −5 °C.

1. Reading the designation

2-NORM = two standards systems (UL/CSA and VDE); CY = copper braid under a PVC sheath. 1.000 V = UL/CSA voltage rating. +UV = black UV-resistant sheath. ‘G’ = with GNYE; ‘X’ = without.

48

Constructions per colour, 3 G 0.5 to 4 G 50 mm² (AWG 21 to 1).

1 000 V

UL/CSA rating.

90 °C

PVC to UL 1581.

≈85 %

Braid coverage.

2. Construction

Cross-section 2-NORM-CY 1 000 V 7 G · Cu braid, 90 °C PVC, grey or black +UVEngineering-drawing style · functional, not to scale · final dimensions per approved order drawingGNYE123456Ø d = 5.9 … 33.6 mm (see tables) (see tables)1Bare Cu strand, IEC 60228 class 52PVC core insulation, black3White numerals (DIN VDE 0293)4GNYE protective conductor (from 3 cores)5Tinned Cu braid, approx. 85 %6PVC sheath 90 °C: grey RAL 7001 or black RAL 9005 +UVDocumentRevisionProjectionFC-ART-2NCY-2026-D920A · 2026-091st angle
Figure 1: Construction of the 7 G version; callouts match the Pos. column of the materials table.
Materials table (Pos. = callout numbers in Figure 1)
Pos.ElementMaterial / formEngineering function
1ConductorBare Cu, fine-wire, IEC 60228 cl. 5Flexibility; AWG equivalents given for each size
2Core insulationPVC, 90 °C acc. to UL 1581Supports the cURus 90 °C / 1 000 V rating
3Core markingBlack cores with white numeralsClear identification in multicore circuits
4Protective conductorGNYE core (‘G’)‘X’ versions without GNYE
5Overall screenTinned Cu braid, approx. 85 % coverage, directly over the coresEMC screening; compact design without inner sheath
6Outer sheathPVC 90 °C acc. to UL 1581; grey RAL 7001 or black RAL 9005 (UV-resistant)TM54 oil resistance; IEC 60332-3-24 Cat. C, VW-1, FT1

3. Technical data

Technical data (complete)
ParameterValueEngineering note
Variants2-NORM-CY 1 000 V UL/CSA grey (RAL 7001); 2-NORM-CY +UV 1 000 V UL/CSA black (RAL 9005)Black version UV-resistant, for outdoor use
ConductorBare copper strand, IEC 60228 class 5
Core insulationPVC, 90 °C acc. to UL 1581
Core identificationBlack with white numerals, with (G) or without (X) GNYE
StrandingCores stranded in layers
Overall screenTinned copper braid, coverage approx. 85 %Recommended for EMC applications
Outer sheathPVC, 90 °C acc. to UL 1581
Sheath colourBlack RAL 9005 or grey RAL 7001
Rated voltageUL/CSA: 1 000 V; VDE: 300/500 V1 000 V allows parallel laying with other 1 000 V cables — no separate routing needed
Test voltage6 kV
Conductor resistanceAcc. to IEC 60228 cl. 5
Min. bending radius fixed6 × dBraid adds stiffness vs. unscreened 2-NORM (4 × d)
Min. bending radius moved20 × d
Operating temp. fixed−40 °C / +90 °C
Operating temp. moved−5 °C / +90 °C
Burning behaviourSelf-extinguishing acc. to IEC 60332-1; flame-retardant acc. to IEC 60332-3-24 (Cat. C), CSA FT1, UL VW-1, CEI 20-22 II, NBN C30-004 Cat. F2Bunched-cable and North American flame tests
Oil resistanceAcc. to DIN EN 50290-2-22 / VDE 0819-102 TM54
Chemical resistanceResistant to oil; largely resistant to acids and bases
ApprovalsUL/CSA: cURus – 90 °C / 1 000 V; VDE production expertise (VDE-Reg.)
ComplianceRoHS; 2014/35/EU Low Voltage Directive (CE); LABS-/silicone-free during production

4. Ratings and fire tests

What each rating covers
Rating / testScopeMeaning for the designer
cURus 90 °C / 1 000 VUSA and CanadaParallel laying with 1 000 V cables; 90 °C conductor rating
VDE 300/500 V (VDE-Reg.)EuropeVoltage basis for IEC installations
IEC 60332-3-24 Cat. CBunched cablesReduced fire propagation in trays and risers
UL VW-1 / CSA FT1Single cable, North AmericaVertical flame test
CEI 20-22 II / NBN C30-004 F2Italy / BelgiumNational flame-propagation categories
TM54 (EN 50290-2-22)OilSheath oil resistance for machine tools

EMC and termination

1. Bond the braid 360° with EMC glands at both ends; avoid pigtails. 2. Use UL-listed EMC glands for North American panels. 3. Keep the braid continuous up to the gland. 4. Segregate screened control cables from unscreened power cables where possible.

5. Full dimension and weight tables

All 48 constructions are listed for both colours, grouped by cross-section with AWG equivalents. Grey and black versions share dimensions and weights. Bending radii are calculated from the nominal outer diameter (6 × d fixed, 20 × d moved).

Cross-section 0.5 mm² / AWG 21 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 5 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
3 G 0.5100505210021655.931.054.035118
4 G 0.5100505310021666.339.068.038126
5 G 0.5100505410021836.944.079.041138
7 G 0.5100505510021867.459.097.044148
12 G 0.5100505610021909.394.0149.056186
Cross-section 0.75 mm² / AWG 19 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 9 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
2 x 0.75100506010022106.030.054.036120
3 G 0.75100506110022116.343.068.038126
4 G 0.75100506210022126.851.080.041136
5 G 0.75100506310022137.463.099.044148
7 G 0.75100506410022158.079.0118.048160
12 G 0.751005065100221910.3127.0188.062206
18 G 0.751005066100222312.2179.0272.073244
25 G 0.751005067100222814.3252.0374.086286
34 G 0.751005068100223316.7325.0493.0100334
Cross-section 1 mm² / AWG 18 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 9 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
2 x 1100506910022416.337.065.038126
3 G 1100507010022426.749.077.040134
4 G 1100507110022437.262.097.043144
5 G 1100507210022447.873.0113.047156
7 G 1100507310022468.497.0141.050168
12 G 11005074100225010.9155.0224.065218
18 G 11005075100225312.9219.0320.077258
25 G 11005076100225815.1308.0440.091302
34 G 11005077100226317.7412.0590.0106354
Cross-section 1.5 mm² / AWG 16 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 8 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
2 x 1.5100507810022716.948.079.041138
3 G 1.5100507910022727.368.0100.044146
4 G 1.5100508010022737.984.0121.047158
5 G 1.5100508110022748.6102.0147.052172
7 G 1.5100508210022769.3135.0185.056186
12 G 1.51005083100228112.3218.0302.074246
18 G 1.51005084100228414.8325.0454.089296
25 G 1.51005085100228917.0434.0595.0102340
Cross-section 2.5 mm² / AWG 14 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 6 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
3 G 2.5100508810024268.6100.0142.052172
4 G 2.5100508910024279.3128.0179.056186
5 G 2.51005090100242810.4153.0219.062208
7 G 2.51005091100243211.3207.0278.068226
12 G 2.51005092100246315.2356.0476.091304
18 G 2.51005093100247117.9514.0693.0107358
Cross-section 4 mm² / AWG 12 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 3 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
4 G 41005094100250011.1193.0262.067222
5 G 41005095100250112.3236.0321.074246
7 G 41005096100250213.6326.0422.082272
Cross-section 6 mm² / AWG 10 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 3 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
4 G 61005097100251213.2288.0384.079264
5 G 61005098100251314.7355.0471.088294
7 G 61005099100251416.1480.0604.097322
Cross-section 10 mm² / AWG 8 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 1 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
4 G 101005100100251616.9460.0616.0101338
Cross-section 16 mm² / AWG 6 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 1 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
4 G 161005101100253019.5705.0891.0117390
Cross-section 25 mm² / AWG 4 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 1 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
4 G 251005102100253324.61,081.01,380.0148492
Cross-section 35 mm² / AWG 2 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 1 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
4 G 351005103100253727.71,487.01,823.0166554
Cross-section 50 mm² / AWG 1 · UL/CSA 1 000 V · VDE 300/500 V · screened · grey and black · 1 constructions
Dimension n × mm²Item no. grey (ref.)Item no. black +UV (ref.)Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 20 × d mm
4 G 501005104100257833.62,136.02,645.0202672

6. Application envelope

Power, control and connecting cable in electrical facilities, for fixed laying and flexible applications with free movement, without tensile stress and without forced guidance. Suitable for dry, humid and wet rooms, including water-oil mixtures. Outdoor use with the black type only; not for burial.

Application envelope of 2-NORM-CY 1 000 V UL/CSA ✔ Machine tools, coolant Water-oil mixtures; TM54 oil resistance ✔ Machines, 1 000 V trays Free movement ≥ 12.5 × d, above −5 °C ✘ Not designed for • Drag chains / forced guidance• Tensile load, reels, festoons• Direct burial• Outdoors with the grey type• Flexing below −5 °C / pigtails Terminate the braid 360° with EMC glands;for chains a PUR/TPE chain cable. Suitable for dry, humid and wet rooms. Outdoor only with the black +UV type; parallel laying with 1 000 V cables permitted.
Figure 2: Permitted duties and exclusions.

7. Comparison

2-NORM-CY 1 000 V compared with related cables
TypeApprovalsVoltageTemperatureFlameTypical use
MULTINORM H05VV5-FHAR + UL + CSA300/500 V · UL/CSA 600 V70 °C HAR / 90 °C ULIEC 60332-1, VW-1, FT1Harmonised EU + NA control
ÖPVC-JZ/OZ-Yö UL/CSAUL 2570 / CSA AWMIEC 450/750 V · UL 1 000 V80 °CIEC 60332-3-24 Cat. C, FT1Dual-rated machine wiring
2-NORM 1 000 V UL/CSA (unscreened)cURus + VDE-Reg.VDE 300/500 V · UL/CSA 1 000 V90 °CIEC 60332-3-24 Cat. C, VW-1, FT1, F21 000 V machines, unscreened
2-NORM-CY 1 000 V UL/CSAcURus + VDE-Reg., screenedVDE 300/500 V · UL/CSA 1 000 V90 °CIEC 60332-3-24 Cat. C, VW-1, FT1, F2EMC control in 1 000 V machines; black +UV outdoors

8. Design calculations

North American machinery: NFPA 79 / UL ampacity, 90 °C cable rating (terminal ratings may limit to 60/75 °C) IEC installation: DIN VDE base rating × f(ambient) × f(grouping) × f(loaded cores) Short-circuit (PVC, Cu, IEC basis): I_k ≈ 115 × S / √t e.g. 4 G 50, t = 0.5 s → ≈ 8.1 kA Voltage drop: ΔU = √3 × I × L × (R cosφ + X sinφ) Bending: fixed R ≥ 6 × d · moved R ≥ 20 × d e.g. 25 G 1.5 (d = 17.0 mm): 102 mm / 340 mm

9. Certification and traceability

This screened cable carries cURus recognition (90 °C / 1 000 V) and a VDE production expertise (VDE-Reg.), meets IEC 60332-3-24 Cat. C, UL VW-1, CSA FT1, CEI 20-22 II and NBN C30-004 F2, and is RoHS-conform, CE-conform to 2014/35/EU and LABS-/silicone-free during production. FeiChun Cable holds a complete export certification portfolio — including CE, UKCA, VDE, EAC, ATEX and IECEx — and every certificate supplied is checked against the exact type, voltage, factory and standard of the order.

Routine tests

Conductor resistance, 6 kV voltage test, braid continuity, core numbering, dimensions and marking.

Type tests

IEC 60332-3-24 Cat. C, VW-1, FT1, TM54 oil resistance, UV resistance of the black sheath.

Delivery documents

Approved datasheet, test report per drum, cURus and VDE-Reg. marking, batch number and length marking.

10. FAQ

Why is 1 000 V UL/CSA useful?

North American rules allow cables to share a raceway only if each is rated for the highest voltage present. A 1 000 V rating lets this control cable run alongside 1 000 V power cables, so no second cable route is needed.

Grey or black?

Identical construction and data. Black RAL 9005 is UV-resistant and the only version for outdoor use.

What is VDE-Reg.?

A VDE production expertise (Fertigungsgutachten) confirming that manufacture is monitored by VDE against the stated standard.

Why 90 °C?

Insulation and sheath are 90 °C PVC compounds to UL 1581, so the cable carries a cURus 90 °C rating across the range.

How should the braid be terminated?

360° with EMC glands at both ends; for North American panels use UL-listed EMC glands. Avoid pigtails.

Why no inner sheath?

The braid sits directly over the cores, keeping the cable compact. Where mechanical risk is high, protect the route or choose a type with an inner sheath such as MULTINORM-CY.

Can it be buried?

No — outdoor use (black type only) but not underground.

FeiChun Cable / 飞纯电缆
Technical and project enquiries: [email protected]
Manufacturing in China, export support
+86 13855123218
FEICHUN CABLE

Screened, 1 000 V UL/CSA, 90 °C — indoors in grey, outdoors in black

For machine builders serving Europe and North America.

[email protected]

+86 13855123218

Document FC-ART-2NCY-2026-D920. Final values are governed by the approved datasheet, order drawing, batch test reports and certificate scope.

Previous Article

2-NORM 1 000 V UL/CSA: 90 °C control cable in grey and black +UV

Next Article

ASTM B-33: el conductor de cobre estañado que sostiene la flexibilidad y la confiabilidad del cable minero