How to Properly Strain-Relieve Vertical Suspension Cables ((N)SHTÖU) Using Kellem Grips

如何使用Kellem电缆夹正确对垂直悬挂电缆((N)SHTÖU)进行应力消除

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
How to Properly Strain-Relieve Vertical Suspension Cables ((N)SHTÖU) Using Kellem Grips | Anhui Feichun Special Cable
Anhui Feichun Special Cable Co., Ltd. 安徽飞纯特种电缆有限公司

How to Properly Strain-Relieve Vertical Suspension Cables ((N)SHTÖU) Using Kellem Grips

如何使用Kellem电缆夹正确对垂直悬挂电缆((N)SHTÖU)进行应力消除

1. Introduction to (N)SHTÖU Cables — (N)SHTÖU电缆简介

The (N)SHTÖU cable is a flexible rubber-sheathed cable specifically engineered for reeling and festoon applications in cranes, hoists, and other material handling equipment. According to DIN VDE 0250-814 and harmonized standard HD 22.10 S2, these cables feature exceptional mechanical resilience and are rated for continuous flexing operations under demanding industrial conditions. (N)SHTÖU电缆是专为起重机、提升机及其他物料搬运设备的卷筒和悬链系统设计的柔性橡胶护套电缆。根据DIN VDE 0250-814及协调标准HD 22.10 S2,这类电缆具有出色的机械弹性,适用于严苛工业环境下的连续弯曲操作。

Standard 执行标准DIN VDE 0250-814 / HD 22.10 S2
Rated Voltage 额定电压450/750V (AC) / 600/1000V (DC)
Temperature Range 温度范围-25°C to +60°C (fixed) / -40°C to +60°C (flexible)
Conductor Material 导体材料Class 5 Fine-Stranded Copper per IEC 60228
Sheath Material 护套材料Heavy-duty Polychloroprene (PCP) rubber compound
Minimum Bending Radius 最小弯曲半径7.5 × overall diameter (dynamic use)

2. Understanding Kellem Cable Grips — 认识Kellem电缆夹

Kellem grips (also known as cable pulling grips or Chinese finger grips) are woven wire mesh devices manufactured by Hubbell/Kellems that provide secure strain relief through a self-tightening mechanism. When tensile load is applied, the mesh contracts around the cable jacket, distributing stress evenly across a larger surface area and preventing localized damage to the conductor insulation. Kellem电缆夹(也称为电缆牵引夹或中国指套)是由Hubbell/Kellems制造的编织金属丝网装置,通过自锁机制提供可靠的应力消除。当施加拉力时,丝网收缩包裹在电缆护套上,将应力均匀分布在较大的表面积上,防止导体绝缘层局部损坏。

Key Principle 关键原理: The grip’s holding capacity increases proportionally with the applied load. This “finger trap” mechanism ensures that higher tension results in a more secure grip without requiring additional clamping force. 夹持力随施加负载成比例增加。这种”指套陷阱”机制确保更高的张力带来更牢固的夹持,无需额外的夹紧力。

2.1 Kellem Grip Selection Criteria — Kellem夹选型标准

Cable O.D. Range (mm) 电缆外径范围Grip Model Series 夹具型号系列Safe Working Load 安全工作负载Mesh Material 丝网材料
6.4 – 12.7033-02-xxx227 kg (500 lbs)Galvanized Steel
12.7 – 19.1033-03-xxx454 kg (1,000 lbs)Galvanized Steel
19.1 – 25.4033-04-xxx680 kg (1,500 lbs)Galvanized Steel
25.4 – 38.1033-05-xxx907 kg (2,000 lbs)Galvanized / Stainless
38.1 – 50.8033-06-xxx1,134 kg (2,500 lbs)Stainless Steel 316

3. Step-by-Step Installation Procedure — 分步安装流程

1Calculate Cable Weight Load 计算电缆重量负载

Determine the total suspended cable weight using the formula: W = L × m, where L is the vertical length (m) and m is the cable mass per unit length (kg/m). For (N)SHTÖU 4G2.5, typical mass is approximately 0.28 kg/m. Apply a minimum safety factor of 5:1 per ASME B30.20 standards for below-the-hook lifting devices. 使用公式W = L × m计算悬挂电缆总重量,其中L为垂直长度(米),m为单位长度电缆质量(千克/米)。对于(N)SHTÖU 4G2.5,典型质量约为0.28千克/米。根据ASME B30.20吊钩下起重装置标准,采用最小5:1的安全系数。

2Select Appropriate Grip Size 选择合适的夹具尺寸

Measure the cable outer diameter precisely using calibrated calipers. The grip’s working range should encompass the measured O.D. with 10-15% margin. An undersized grip will not develop full holding capacity; an oversized grip may slip under load. 使用校准卡尺精确测量电缆外径。夹具的工作范围应涵盖测量的外径并留有10-15%的余量。过小的夹具无法发挥全部夹持能力;过大的夹具可能在负载下滑脱。

3Prepare the Cable Surface 准备电缆表面

Clean the cable jacket with isopropyl alcohol to remove oils, dust, and contaminants that could reduce friction. Inspect for jacket damage, cuts, or abrasions that might compromise grip integrity. Do not install grips over damaged sections. 用异丙醇清洁电缆护套,去除可能降低摩擦力的油污、灰尘和杂质。检查护套是否有损坏、切口或磨损,这些都可能影响夹持完整性。不要在损坏部位安装夹具。

4Install the Kellem Grip 安装Kellem夹具

Expand the mesh by pushing toward the closed end (against the weave direction). Slide the cable through until adequate mesh length covers the jacket—minimum 150mm engagement for vertical suspension applications per IEEE 1185 recommendations. Release the mesh to allow it to contract onto the cable. 通过向封闭端推压(逆编织方向)展开丝网。将电缆穿过,直到足够长度的丝网覆盖护套——根据IEEE 1185建议,垂直悬挂应用的最小接合长度为150毫米。释放丝网使其收缩到电缆上。

5Attach to Support Structure 连接到支撑结构

Connect the grip’s eye or bail to the support hardware using appropriately rated shackles or quick-links. Ensure all hardware meets or exceeds the calculated working load limit. Verify that the load path is direct and does not introduce side-loading on the grip eye. 使用额定负载合适的卸扣或快速连接件将夹具的吊环或吊耳连接到支撑硬件。确保所有硬件达到或超过计算的工作负载极限。验证负载路径是否直接,不会对夹具吊环产生侧向载荷。

6Verify and Document Installation 验证并记录安装

Perform a visual inspection and apply a proof load (typically 1.25× working load) before placing into service. Document the installation including grip model, cable type, date, and inspector credentials per ISO 9001 quality management requirements. 在投入使用前进行目视检查并施加验证载荷(通常为工作载荷的1.25倍)。根据ISO 9001质量管理要求记录安装信息,包括夹具型号、电缆类型、日期和检查人员资质。

⚠ Critical Warning 重要警告: Never use Kellem grips as the sole means of electrical grounding. The wire mesh is designed for mechanical strain relief only. Separate grounding conductors must be installed per NEC Article 250 and IEC 60364-5-54 requirements. 切勿将Kellem夹具作为电气接地的唯一手段。金属丝网仅设计用于机械应力消除。必须根据NEC第250条和IEC 60364-5-54要求单独安装接地导体。

4. Load Calculation Reference — 负载计算参考

Cable Type 电缆型号Cross-Section 截面O.D. (mm) 外径Mass (kg/m) 质量Max. Vertical Run* 最大垂直长度*
(N)SHTÖU3G1.510.80.21216 m
(N)SHTÖU4G2.513.20.28324 m
(N)SHTÖU4G414.80.38239 m
(N)SHTÖU4G616.50.52175 m
(N)SHTÖU4G1019.80.78174 m
(N)SHTÖU4G1623.51.15158 m

*Based on 033-series grip with 5:1 safety factor. Actual limits depend on specific grip model selected. 基于033系列夹具,5:1安全系数。实际限值取决于所选具体夹具型号。

5. Common Installation Errors — 常见安装错误

Error Type 错误类型Consequence 后果Prevention 预防措施
Insufficient mesh engagement
丝网接合不足
Reduced holding capacity, potential slippage
夹持力降低,可能滑脱
Ensure minimum 150mm coverage
确保最小150mm覆盖
Oversized grip selection
选择过大的夹具
Grip cannot fully contract, load capacity compromised
夹具无法完全收缩,负载能力受损
Verify O.D. falls within grip’s specified range
验证外径在夹具规定范围内
Side-loading the eye
吊环侧向受力
Premature eye failure, unexpected release
吊环过早失效,意外脱落
Ensure axial alignment of load path
确保负载路径轴向对齐
Installation over damaged jacket
在损坏护套上安装
Jacket tear propagation under load
负载下护套撕裂扩展
Inspect and reject damaged cables
检查并拒绝使用损坏电缆

6. Applicable Standards Summary — 适用标准汇总

Standard 标准Scope 范围
DIN VDE 0250-814Rubber-insulated cables for reeling purposes 卷筒用橡胶绝缘电缆
HD 22.10 S2Harmonized standard for lift and crane cables 电梯和起重机电缆协调标准
IEC 60228Conductor specifications for cables 电缆导体规范
IEEE 1185Cable installation in generating stations 发电站电缆安装
ASME B30.20Below-the-hook lifting devices 吊钩下起重装置
NEC Article 250Grounding and bonding requirements 接地与搭接要求

References & External Resources 参考文献与外部资源

  1. Hubbell Incorporated. “Kellems Cable Support Grips – Engineering Data.” hubbell.com/kellems
  2. DIN Deutsches Institut für Normung. “DIN VDE 0250-814:2022 – Cables for Reeling Purposes.” din.de
  3. International Electrotechnical Commission. “IEC 60228:2023 – Conductors of Insulated Cables.” iec.ch
  4. IEEE Standards Association. “IEEE 1185-2019 – Recommended Practice for Cable Installation.” standards.ieee.org
  5. ASME. “B30.20-2021 – Below-the-Hook Lifting Devices.” asme.org
  6. NFPA. “National Electrical Code (NEC) 2023 – Article 250.” nfpa.org/nec
Company 公司 Anhui Feichun Special Cable Co., Ltd.
安徽飞纯特种电缆有限公司
Technical Support 技术支持 [email protected]
Sales Inquiries 销售咨询 [email protected]
[email protected]

© 2025 Anhui Feichun Special Cable Co., Ltd. All rights reserved. 版权所有。

This technical guide is provided for informational purposes. Always consult qualified engineers for specific applications.
本技术指南仅供参考。具体应用请咨询合格工程师。

Previous Article

Conductix-Wampfler Festoon Systems: Choosing the Right (N)TSFLCGEWÖU Flat Cable

Next Article

Splicing Type 241 Mining Cables: AS/NZS 1747 Repair Standards Explained

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注