ÖPVC-JZ/OZ-CYö 1 000 V UL/CSA: one screened EMC control cable for IEC and North American machines

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
ÖPVC-JZ/OZ-CYö 1 000 V UL/CSA screened control cable | FeiChun Cable
FEICHUN CABLE · UL/CSA SCREENED OIL-RESISTANT CONTROL CABLE

ÖPVC-JZ/OZ-CYö 1 000 V UL/CSA: one screened EMC control cable for IEC and North American machines

An engineering guide to a dual-rated screened PVC control cable with a tinned copper braid of 85 % ± 5 % coverage: UL 1 000 V and IEC 450/750 V, cURus 80 °C, increased mineral-oil resistance, a 6 kV test voltage and bunched-cable fire performance to IEC 60332-3-24 Cat. C and CSA FT1.

UL Style 2570CSA AWM I A/B II A/BcURus 80 °C · 1 000 VIEC 450/750 VIEC 60332-3-24 Cat. CCSA FT1CEI 20-22 IINBN C30-004 F26 kV testCu braid 85 % ± 5 %RoHS · CE
Document FC-ART-JZCYUL-2026-DC53Updated: 20 September 2026FeiChun Cable / 飞纯电缆
Engineer’s summary: this cable combines dual UL/CSA–IEC compliance, EMC screening, increased mineral-oil resistance and bunched-cable fire performance. A machine builder can use one screened control cable for both markets. Remember two limits: it is AWM (equipment wiring), not an NEC field-wiring tray cable, it must not be flexed below −5 °C, and the moved bending radius is 20 × d.

1. Reading the designation

JZ = with GNYE and numbered cores (‘G’); OZ = without GNYE (‘x’). C denotes the tinned copper braid; Yö the oil-resistant PVC sheath (‘ö’ for Öl, oil). 1 000 V UL/CSA refers to the UL Style 2570 / CSA AWM rating; the same cable is rated 450/750 V under IEC.

81

Standard constructions, 2 × 0.5 to 5 G 16 mm².

6 kV

Test voltage.

1 000 V

cURus at 80 °C.

85 %

Braid coverage ± 5 %.

2. Construction

The tinned braid is applied directly over the core assembly, giving a compact screened cable. The sheath compound is formulated for increased mineral-oil resistance and bunched-cable flame performance, and the insulation system is dimensioned for the UL 1 000 V rating and a 6 kV test.

Cross-section ÖPVC-JZ-CYö UL/CSA 7 G · Cu braid, oil-resistant FT1 sheathEngineering-drawing style · functional, not to scale · final dimensions per approved order drawingGNYE123456Ø d = 5.6 … 24.9 mm (see tables)1Bare Cu strand, IEC 60228 class 52PVC core insulation, black3White numerals (DIN VDE 0293)4GNYE protective conductor (JZ)5Tinned Cu braid, 85 % ± 5 %6Oil-resistant PVC sheath RAL 7001, CSA FT1DocumentRevisionProjectionFC-ART-JZCYUL-2026-DC53A · 2026-091st angle
Figure 1: Construction of the 7 G version; callouts match the Pos. column of the materials table.
Materials table (Pos. = callout numbers in Figure 1)
Pos.ElementMaterial / formEngineering function
1ConductorBare Cu, fine-wire, IEC 60228 cl. 5Flexibility for installation and free movement
2Core insulationPVC, black (coloured to DIN VDE 0293-308 on request)UL 80 °C / 1 000 V rating; 6 kV test
3Core markingWhite numerals per DIN VDE 0293Unambiguous identification in multicore circuits
4Protective conductorGNYE core in JZ (‘G’) versionsOZ (‘x’) versions have none
5Core assemblyStranded in layersRound geometry under the braid
6Overall screenTinned Cu braid, optical coverage 85 % ± 5 %EMC screening directly over the cores
7Outer sheathOil-resistant PVC ‘Yö’, grey RAL 7001Increased mineral-oil resistance; IEC 60332-3-24 Cat. C, CSA FT1

3. Technical data

Technical data (complete)
ParameterValueEngineering note
Conductor materialBare copper strand
Conductor classIEC 60228 class 5
Core insulationPVC
Core identificationAcc. to DIN VDE 0293: black cores with white numerals, with or without GNYEAlso available with coloured cores acc. to DIN VDE 0293-308, with or without GN/YE
StrandingCores stranded in layers
Overall screenTinned copper braid, optical coverage 85 % ± 5 %Recommended for EMC applications
Outer sheathPVC (oil-resistant)
Sheath colourGrey, RAL 7001
Rated voltageUL: 1 000 V; IEC: 450/750 VOne cable, two rating systems
Test voltage6 kV
Conductor resistanceAcc. to IEC 60228 class 5
Insulation resistanceMin. 20 MΩ × km
Current carrying capacityAcc. to DIN VDEFor NEC installations apply the NEC/UL ampacity basis
Min. bending radius fixed6 × dBraid adds stiffness vs. unscreened Yö (4 × d)
Min. bending radius moved20 × dStricter than the 15 × d of the non-UL CY type
Operating temp. fixed−40 °C / +80 °C
Operating temp. moved−5 °C / +80 °CNote: higher lower limit than standard PVC types (−15 °C)
Burning behaviourSelf-extinguishing acc. to IEC 60332-1; reduced fire propagation and flame-retardant acc. to IEC 60332-3-24 (Cat. C), CEI 20-22 II (00), NBN C30-004 Cat. F2, CSA FT1Bunched-cable fire performance, not only single-cable
Chemical resistanceIncreased oil resistance; largely resistant to acids and bases
StandardUL Style 2570 / CSA AWM I A/B II A/B
ApprovalscURus: 80 °C – 1 000 V
ComplianceRoHS; 2014/35/EU Low Voltage Directive (CE); LABS-/silicone-free during production
Installation remarkWhere mechanical damage risk exists, protect with tubes, channels, etc.

4. Fire performance: what each test proves

Flame tests met by the cable
TestConfigurationWhat it demonstrates
IEC 60332-1Single vertical cable, 1 kW burnerSelf-extinguishing; flame does not travel along a single cable
IEC 60332-3-24 Cat. CBunched vertical cables, 1.5 l/m non-metallic volume, 20 minReduced fire propagation in cable trays and risers
CEI 20-22 IIItalian bunched-cable testAcceptance in Italian installations
NBN C30-004 Cat. F2Belgian flame-propagation categoryAcceptance in Belgian installations
CSA FT1Vertical flame test, CanadaCanadian flame rating for the AWM listing
IEC 60332-3-24 Cat. C is a propagation test, not fire resistance: the cable is not designed to keep circuits working during a fire. Where circuit integrity is required, specify a fire-resistant cable.

EMC and termination

1. Bond the braid 360° with EMC glands at both ends for drive and switching noise; avoid pigtails. 2. Use UL-listed EMC glands for North American panels. 3. Segregate screened control cables from unscreened power cables. 4. For ground-loop-sensitive analogue signals, follow the equipment manufacturer.

5. Full dimension and weight tables

All 81 constructions are listed, grouped by cross-section. Outer diameters are supplier values; bending radii are calculated from them.

Source data to verify before publication: 7 G 2.5 shows Cu index 296.0 = weight 296.0 kg/km, and the Cu index is out of sequence (5 G 2.5: 152.4; 12 G 2.5: 354.1). Shown as received.
Cross-section 0.5 mm² · UL 1 000 V / IEC 450/750 V · screened · 11 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (6 × d) mmMin. bend radius moved (20 × d) mm
2 x 0.5OZ (without GNYE)10014625.622.443.034112
3 G 0.5JZ (with GNYE)10014735.927.351.035118
4 G 0.5JZ (with GNYE)10014776.336.668.038126
5 G 0.5JZ (with GNYE)10014806.941.779.041138
7 G 0.5JZ (with GNYE)10014867.456.0101.044148
12 G 0.5JZ (with GNYE)10014879.390.1159.056186
14 G 0.5JZ (with GNYE)100149010.199.8176.061202
16 G 0.5JZ (with GNYE)100149110.8109.2198.065216
18 G 0.5JZ (with GNYE)100149211.0123.6222.066220
25 G 0.5JZ (with GNYE)100149312.7178.1310.076254
34 G 0.5JZ (with GNYE)100149415.1229.3405.091302
Cross-section 0.75 mm² · UL 1 000 V / IEC 450/750 V · screened · 15 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (6 × d) mmMin. bend radius moved (20 × d) mm
2 x 0.75OZ (without GNYE)10015016.027.352.036120
3 G 0.75JZ (with GNYE)10015046.339.068.038126
4 G 0.75JZ (with GNYE)10015056.846.380.041136
5 G 0.75JZ (with GNYE)10015067.458.4102.044148
7 G 0.75JZ (with GNYE)10015078.073.3122.048160
12 G 0.75JZ (with GNYE)100151010.3119.0199.062206
14 G 0.75JZ (with GNYE)100151111.2137.8226.067224
16 G 0.75JZ (with GNYE)100151211.9152.3255.071238
18 G 0.75JZ (with GNYE)100151312.2171.3285.073244
25 G 0.75JZ (with GNYE)100151414.3246.0397.086286
34 G 0.75JZ (with GNYE)100151516.7319.0519.0100334
37 G 0.75JZ (with GNYE)100151716.7340.6544.0100334
42 G 0.75JZ (with GNYE)100151917.8385.1630.0107356
50 G 0.75JZ (with GNYE)100152319.4450.8723.0116388
61 G 0.75JZ (with GNYE)100152421.0538.3857.0126420
Cross-section 1 mm² · UL 1 000 V / IEC 450/750 V · screened · 15 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (6 × d) mmMin. bend radius moved (20 × d) mm
2 x 1OZ (without GNYE)10015256.336.663.038126
3 G 1JZ (with GNYE)10015276.746.377.040134
4 G 1JZ (with GNYE)10015287.260.897.043144
5 G 1JZ (with GNYE)10015297.870.9117.047156
7 G 1JZ (with GNYE)10015318.495.0146.050168
12 G 1JZ (with GNYE)100153210.9152.6236.065218
14 G 1JZ (with GNYE)100153312.0171.5269.072240
16 G 1JZ (with GNYE)100153512.6195.3303.076252
18 G 1JZ (with GNYE)100153612.9230.4357.077258
25 G 1JZ (with GNYE)100153815.1306.1464.091302
34 G 1JZ (with GNYE)100153917.7409.1627.0106354
37 G 1JZ (with GNYE)100154017.7437.9658.0106354
42 G 1JZ (with GNYE)100154119.2494.2761.0115384
50 G 1JZ (with GNYE)100154221.3579.1873.0128426
61 G 1JZ (with GNYE)100154322.3692.81,046.0134446
Cross-section 1.5 mm² · UL 1 000 V / IEC 450/750 V · screened · 15 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (6 × d) mmMin. bend radius moved (20 × d) mm
2 x 1.5OZ (without GNYE)10015446.946.576.041138
3 G 1.5JZ (with GNYE)10015477.365.6103.044146
4 G 1.5JZ (with GNYE)10015487.980.5125.047158
5 G 1.5JZ (with GNYE)10015508.699.9156.052172
7 G 1.5JZ (with GNYE)10015519.3133.3195.056186
12 G 1.5JZ (with GNYE)100155212.3214.5315.074246
14 G 1.5JZ (with GNYE)100155413.7259.2378.082274
16 G 1.5JZ (with GNYE)100156014.4296.6428.086288
18 G 1.5JZ (with GNYE)100159514.8325.3478.089296
25 G 1.5JZ (with GNYE)100159617.0434.1630.0102340
34 G 1.5JZ (with GNYE)100164120.0580.5850.0120400
37 G 1.5JZ (with GNYE)100166020.0623.7895.0120400
42 G 1.5JZ (with GNYE)100173022.0704.31,032.0132440
50 G 1.5JZ (with GNYE)100183723.8861.81,235.0143476
61 G 1.5JZ (with GNYE)100186024.91,033.51,464.0149498
Cross-section 2.5 mm² · UL 1 000 V / IEC 450/750 V · screened · 11 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (6 × d) mmMin. bend radius moved (20 × d) mm
2 x 2.5OZ (without GNYE)10018818.171.2112.049162
3 G 2.5JZ (with GNYE)10018828.699.9151.052172
4 G 2.5JZ (with GNYE)10018839.3128.5189.056186
5 G 2.5JZ (with GNYE)100188510.4152.4230.062208
7 G 2.5JZ (with GNYE)100188611.3296.0296.068226
12 G 2.5JZ (with GNYE)100188715.2354.1500.091304
14 G 2.5JZ (with GNYE)100199616.7410.7579.0100334
16 G 2.5JZ (with GNYE)100208017.7458.3653.0106354
18 G 2.5JZ (with GNYE)100208317.9514.5730.0107358
25 G 2.5JZ (with GNYE)100209621.3699.1973.0128426
34 G 2.5JZ (with GNYE)100212124.7958.01,346.0148494
Cross-section 4 mm² · UL 1 000 V / IEC 450/750 V · screened · 4 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (6 × d) mmMin. bend radius moved (20 × d) mm
2 x 4OZ (without GNYE)10021279.4109.5163.056188
3 G 4JZ (with GNYE)100212810.1147.6213.061202
4 G 4JZ (with GNYE)100212911.1190.6269.067222
5 G 4JZ (with GNYE)100213012.3233.7334.074246
Cross-section 6 mm² · UL 1 000 V / IEC 450/750 V · screened · 4 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (6 × d) mmMin. bend radius moved (20 × d) mm
2 x 6OZ (without GNYE)100213511.0152.4221.066220
3 G 6JZ (with GNYE)100213611.7214.5300.070234
4 G 6JZ (with GNYE)100213713.2288.4399.079264
5 G 6JZ (with GNYE)100213914.7354.1494.088294
Cross-section 10 mm² · UL 1 000 V / IEC 450/750 V · screened · 3 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (6 × d) mmMin. bend radius moved (20 × d) mm
3 G 10JZ (with GNYE)100214315.3353.9480.092306
4 G 10JZ (with GNYE)100214516.9458.4619.0101338
5 G 10JZ (with GNYE)100214618.9562.7776.0113378
Cross-section 16 mm² · UL 1 000 V / IEC 450/750 V · screened · 3 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (6 × d) mmMin. bend radius moved (20 × d) mm
3 G 16JZ (with GNYE)100214717.6543.4698.0106352
4 G 16JZ (with GNYE)100215019.5705.2900.0117390
5 G 16JZ (with GNYE)100215222.2867.11,125.0133444

6. Application envelope

Power, control and connecting cable in electrical facilities where increased mineral-oil resistance is required. For fixed laying and flexible applications with free movement, without tensile stress and without forced guidance. Suitable for dry, humid and wet rooms. Outdoor use only with UV protection; not for burial. Where mechanical damage risk exists, install in tubes, channels or similar. Recommended for EMC applications.

Application envelope of ÖPVC-JZ/OZ ✔ Drive to motor (VSD) 360° braid bonding at both ends ✔ UL/CSA machines, oil mist Free movement ≥ 20 × d, above −5 °C ✘ Not designed for • Drag chains / forced guidance• Tensile load, reels, festoons• Direct burial• Outdoors without UV protection• Flexing below −5 °C Use a PUR/TPE screened chain cablefor drag chains. Suitable for dry, humid and wet rooms. Suitable for dry, humid and wet rooms; the braid works only if terminated 360°.
Figure 2: Permitted duties and exclusions.

7. Comparison

JZ/OZ-CYö UL/CSA compared with related cables
TypeVoltageTest voltageFireOilTypical use
ÖPVC-JZ/OZ-CY300/500 V4 kV / 2 kVIEC 60332-1Largely oil-resistantIEC screened control
ÖPVC-JZ/OZ (standard)300/500 V4 kVIEC 60332-1TM54 oil resistanceIEC markets, general wiring
ÖPVC-JZ/OZ-CYö UL/CSAUL 1 000 V · IEC 450/750 V6 kVIEC 60332-3-24 Cat. C, CSA FT1Increased mineral-oil resistanceScreened control in machines for North America and Europe
ÖPVC-JB/OB-YCY300/500 V · 0.6/1 kV4 kVIEC 60332-1Largely oil-resistantEMC-screened circuits
UL TC-ER (tray cable)600 V—UL 1685 / FT4Per jacketUS tray installations, exposed runs

8. Design calculations

IEC installation: DIN VDE base rating × f(ambient) × f(grouping) × f(loaded cores) UL/NEC equipment: use the ampacity basis of the applicable product standard (e.g. NFPA 79 for industrial machinery) Short-circuit (PVC, Cu): I_k ≈ 115 × S / √t e.g. 5 G 16, t = 0.5 s → ≈ 2.6 kA Voltage drop: ΔU = √3 × I × L × (R cosφ + X sinφ) Bending: fixed R ≥ 6 × d · moved R ≥ 20 × d e.g. 50 G 1.5 (d = 23.8 mm): 143 mm / 476 mm Moved below −5 °C: not permitted

9. Certification and traceability

This cable carries cURus recognition (80 °C, 1 000 V) under UL Style 2570 and CSA AWM I A/B II A/B, meets IEC 60332-3-24 Cat. C, CEI 20-22 II, NBN C30-004 F2 and CSA FT1, and is RoHS-conform, CE-conform to 2014/35/EU and LABS-/silicone-free during production. FeiChun Cable backs this with a complete export certification portfolio — including CE, UKCA, VDE, EAC, ATEX and IECEx — and every certificate supplied is checked against the exact type, voltage, factory and standard of the order.

Routine tests

Conductor resistance, 6 kV voltage test, braid continuity, insulation resistance, core numbering, dimensions and marking.

Type tests

Bunched flame (IEC 60332-3-24 Cat. C), CSA FT1, mineral-oil immersion, sheath ageing.

Delivery documents

Approved datasheet, test report per drum, UL/CSA marking, batch number and length marking.

10. FAQ

Why two voltage ratings?

UL/CSA AWM Style 2570 rates the cable at 1 000 V; under IEC it is rated 450/750 V. One cable can therefore be used in a machine shipped to either market.

What does cURus mean?

UL Recognized Component marking valid for both the US and Canada, here for 80 °C and 1 000 V as appliance wiring material (AWM).

Is AWM the same as a field-wiring tray cable?

No. AWM is for wiring within equipment and machines. Field wiring in buildings under the NEC normally requires listed types such as TC-ER. Check the installation code.

What is IEC 60332-3-24 Cat. C?

A bunched-cable vertical flame test: a defined non-metallic volume of cables must not propagate flame beyond a set height. It is stricter than the single-cable IEC 60332-1 test.

Why −5 °C when moved?

The oil-resistant sheath compound is optimised for oil resistance and fire behaviour; below −5 °C, avoid flexing. Fixed installation remains possible down to −40 °C.

How many cores?

From 2 to 61 cores in 0.75–1.5 mm², up to 34 cores in 0.5 and 2.5 mm², and 2–5 cores from 4 to 16 mm².

FeiChun Cable / 飞纯电缆
Technical and project enquiries: [email protected]
Manufacturing in China, export support
+86 13855123218
FEICHUN CABLE

One screened, oil-resistant control cable for IEC and UL/CSA machines

For machine tools, control panels and export equipment.

[email protected]

+86 13855123218

Document FC-ART-JZCYUL-2026-DC53. Final values are governed by the approved datasheet, order drawing, batch test reports and certificate scope.