What is BS 6708 Type 21 Trailing Cable?

Four-Core Galvanized Steel Pliable Wire Armoured Cable with Dedicated Earth Conductor for Mining Excavating and Crushing Equipment in Explosive Atmosphere Applications — Comprehensive Technical Analysis

BS 6708 Type 21 Trailing Cable
BS 6708 Type 21 Trailing Cable
What is BS 6708 Type 21 Trailing Cable? | Four-Core Armoured Mining Cable Guide | Feichun Cables

What is BS 6708 Type 21 Trailing Cable?

Four-Core Galvanized Steel Pliable Wire Armoured Cable with Dedicated Earth Conductor for Mining Excavating and Crushing Equipment in Explosive Atmosphere Applications — Comprehensive Technical Analysis

Introduction to BS 6708 Type 21 Mining Cable

The BS 6708 Type 21 mining cable represents an advanced variant of galvanized steel pliable wire armoured flexible cables specifically engineered for demanding mining and quarrying applications requiring a dedicated fourth earth conductor. This four-core configuration distinguishes Type 21 from the three-core Type 20, providing enhanced safety features and compliance with electrical regulations that mandate separate protective earth conductors in mining installations.

Key Identification: Type 21 cables feature four unscreened cores (three phase conductors plus one earth conductor) laid up around an elastomeric cradle without contacting each other, protected by galvanized steel pliable armour between inner and outer sheaths. Rated at 640/1100V with a 3kV test voltage, these cables are designed for use in deep mines where explosive gases and dust can accumulate, as well as surface operations supplying excavating, crushing machines and equipment.

According to BS 6708:1998 standard documentation, Type 20 and Type 21 cables are specifically categorized as cables with galvanized steel pliable wire armouring having unscreened cores and a rated voltage of 640/1100V. The critical distinction is the core count: Type 20 provides three cores (relying on armour for earth return), while Type 21 provides four cores with a dedicated earth conductor providing enhanced fault protection and regulatory compliance.

The development of Type 21 cables addresses the mining industry’s evolving safety requirements where separate earth conductors ensure more reliable protective earth systems. As documented by AmplexMining.com.au’s comprehensive mining cable guide, mining cables must possess exceptional ruggedness to survive crushing forces from heavy equipment, abrasion from constant contact with rough surfaces, and the mechanical stress of being dragged, twisted, and flexed thousands of times during their service life. Type 21 cables achieve this while providing the additional safety assurance of a dedicated earth path.

With copper weights ranging from 96 kg/km (4×2.5mm²) to 5,760 kg/km (4×150mm²), Type 21 cables demonstrate significant investment in conductor material, reflecting their robust construction for heavy-duty mining applications. The additional fourth core increases cable diameter and weight compared to Type 20 equivalents, but provides critical safety advantages that justify these increases in demanding applications.

Type 21 vs Type 20: Comparative Analysis

Understanding the differences between BS 6708 Type 21 and Type 20 cables is essential for proper cable selection. Both cable types share the same fundamental construction principles but differ in core configuration and earthing philosophy:

ParameterType 20 (3-Core)Type 21 (4-Core)Difference
Core Configuration3×Phase cores3×Phase + 1×Earth core+1 dedicated earth
Earth Return PathVia steel armour onlyDedicated copper conductor + armourDual earth path
25mm² Max. Diameter47.0 mm49.8 mm+2.8 mm (+6.0%)
25mm² Cable Weight3,350 kg/km4,030 kg/km+680 kg/km (+20.3%)
25mm² Copper Weight720 kg/km960 kg/km+240 kg/km (+33.3%)
25mm² Min. Bend Radius423 mm449 mm+26 mm (+6.1%)
Earth Fault Current PathLimited by armour resistanceFull copper conductor capacitySuperior fault clearing
Earth Continuity MonitoringArmour resistance measurementDirect conductor continuity testSimpler verification

Quantitative Comparison: 120mm² Configuration

Detailed Parameter Comparison (120mm² cables):

Physical Dimensions:
• Type 20: Ø77.0mm, 10,650 kg/km, 3,456 kg Cu/km
• Type 21: Ø89.0mm, 13,450 kg/km, 4,608 kg Cu/km
• Diameter Increase: +12.0mm (+15.6%)
• Weight Increase: +2,800 kg/km (+26.3%)
• Copper Increase: +1,152 kg/km (+33.3%)

Electrical Parameters:
• Current Rating: 295A (identical for both types)
• Conductor Resistance: 0.164 Ω/km (identical)
• Type 20 Armour Resistance: 0.74 Ω/km
• Type 21 Armour Resistance: 0.47 Ω/km
• Type 21 Earth Conductor Resistance: 0.164 Ω/km

Earth Fault Current Advantage:
Type 21 provides parallel earth paths: copper conductor (0.164 Ω/km) in parallel with armour (0.47 Ω/km), resulting in effective earth resistance of approximately 0.121 Ω/km—significantly lower than Type 20’s armour-only resistance of 0.74 Ω/km.

Selection Criteria: When to Choose Type 21

Choose Type 21 when:

  • Local mining regulations mandate separate earth conductors
  • Maximum earth fault current capacity is required
  • Earth continuity monitoring systems require dedicated conductor
  • Critical equipment demands highest safety standards
  • Insurance or certification requirements specify four-core cables
  • Longer cable runs where armour resistance becomes limiting factor

Type 20 may be acceptable when:

  • Regulations permit armour-only earth systems
  • Weight minimization is critical
  • Space constraints limit cable diameter
  • Short cable runs with adequate armour conductivity
  • Cost optimization is primary consideration

Purpose and Primary Applications

Core Application Areas

BS 6708 Type 21 mining cables serve as critical power transmission infrastructure for heavy-duty mining equipment, with the dedicated earth conductor providing enhanced safety assurance in the following applications:

Primary Power Distribution

  • Excavating Machinery: Electric shovels, draglines, and bucket-wheel excavators requiring up to 320A continuous current (150mm² configuration)
  • Crushing Equipment: Primary jaw crushers, secondary cone crushers, and mobile crushing plants with high starting currents
  • Material Handling: Conveyors, stackers, and reclaimers with variable load demands
  • Processing Equipment: Screening systems, feeders, and sizing equipment

Underground Mining Applications

Type 21 cables excel in underground environments where enhanced earth protection is critical:

  • Development Headings: Continuous miners and roadheaders
  • Longwall Operations: Armoured face conveyors and shearer loaders
  • Auxiliary Systems: Ventilation fans and dewatering pumps
  • Safety-Critical Equipment: Emergency systems requiring reliable earth protection
Operating Environment Specifications:
Type 21 cables are specifically designed for use in:
• Deep mines where explosive gases (methane CH₄ concentrations up to 5% LEL) may accumulate
• Areas with combustible dust (coal dust with particle sizes <75μm)
• Surface mining operations with extreme environmental exposure
• Temperature range: -20°C to +85°C (fixed installation)
• Installation temperature: +5°C to +60°C
• Maximum conductor temperature: 90°C continuous operation

Quarrying and Surface Mining

Surface applications benefit from Type 21’s robust construction:

  • Dimension Stone Quarries: Granite, marble, and limestone extraction with mobile equipment
  • Aggregate Production: Sand, gravel, and crushed stone processing facilities
  • Open-Pit Mining: Large-scale earth-moving operations with electric shovels
  • Mineral Processing: Concentration plants and material handling systems

According to ReelingCable.com technical specifications, professional mining cables for heavy-duty mobile equipment must provide fire retardancy, oil resistance, and robust mechanical protection. Type 21 cables achieve these requirements through their EPR insulation, chloroprene sheath, and galvanized steel pliable armour combination, making them suitable for underground mining, surface mining, and quarry operations requiring the highest safety standards.

Cable Construction and Material Structure

The Type 21 cable construction represents sophisticated multi-layer engineering where each component serves specific protective and functional purposes. The addition of the fourth earth core requires optimized layup geometry while maintaining the mechanical robustness essential for mining applications.

1 CONDUCTOR – Electrolytic Tinned Copper (IEC 60228 Class 5)

All four conductors (three phase + one earth) utilize electrolytic, stranded, tinned copper wire conforming to IEC 60228 Class 5 specifications. This classification provides maximum flexibility through fine-wire construction:

Conductor Stranding Details:
• 4×2.5mm²: 50 strands × 0.25mm diameter = 3.13mm² actual
• 4×25mm²: 196 strands × 0.40mm diameter = 24.6mm² actual
• 4×70mm²: 360 strands × 0.50mm diameter = 70.7mm² actual
• 4×150mm²: 740 strands × 0.50mm diameter = 145.5mm² actual

Material Properties:
• Electrical Conductivity: ≥58 MS/m (100% IACS)
• Tinning: Hot-dip or electroplating (2-3% resistance increase)
• Tensile Strength: ~200 N/mm² (annealed copper)
• Elongation: ≥30% (ensures flexibility without breakage)
2 INSULATION – Ethylene Propylene Rubber (EPR)

EPR insulation provides exceptional electrical isolation with superior mechanical and thermal properties. According to Eland Cables technical reference, EPR offers high dielectric strength, excellent ozone and weathering resistance, and a wide thermal range from -55°C to 150°C.

EPR Insulation Parameters:
• Dielectric Strength: >20 kV/mm
• Volume Resistivity: >10¹⁴ Ω·cm
• Dielectric Constant (εr): 2.5-3.5 @ 1 kHz
• Dissipation Factor (tan δ): <0.01 @ 1 kHz
• Temperature Rating: 90°C continuous, 200°C short-circuit

Insulation Thickness (per core):
• 4×2.5mm² to 4×4mm²: 1.4 mm
• 4×6mm² to 4×16mm²: 1.5 mm
• 4×25mm² to 4×50mm²: 1.6-1.7 mm
• 4×70mm² to 4×95mm²: 1.8-2.0 mm
• 4×120mm² to 4×150mm²: 2.2-2.3 mm
3 LAYUP CONFIGURATION – Four-Core Symmetrical Assembly

Four unscreened cores (three phase + one earth) are laid up around an elastomeric cradle without contacting each other. This configuration differs from Type 20’s three-core arrangement:

Four-Core Layup Advantages:
• Geometric Symmetry: Square/rhomboid configuration provides balanced mechanical stress distribution
• Thermal Balance: Earth core provides heat sink effect, improving thermal performance
• Electrical Symmetry: Four-core arrangement reduces electromagnetic unbalance
• Fault Isolation: Earth core provides physical separation between phases
• Identification: Distinct earth core color coding (green/yellow) for installation verification

The elastomeric cradle (EPR-based compound) maintains consistent core spacing throughout cable length, ensuring uniform electrical characteristics and accommodating differential thermal expansion during operation.

4 BEDDING COMPOUND – Rubber-Based Protective Layer

Rubber-based bedding compound provides critical interface protection between cable cores and metallic armour:

Inner Sheath Radial Thickness:
• 4×2.5mm² to 4×4mm²: 2.0 mm
• 4×6mm² to 4×50mm²: 2.5 mm
• 4×70mm² to 4×95mm²: 2.5-3.8 mm
• 4×120mm² to 4×150mm²: 3.8-5.0 mm

Functions:
• Mechanical cushioning preventing armour damage to insulation
• Fire barrier retarding flame propagation along cores
• Moisture barrier preventing water migration
• Accommodation of differential thermal expansion
5 ARMOUR – Galvanized Steel Pliable Wire (7-Wire Strands)

The galvanized steel pliable armour comprises seven-wire strands wound helically to provide mechanical protection while maintaining flexibility. According to Tratos Group armoured cable specifications, pliable wire armour (PWA) cables are specifically designed for mining applications requiring armoured protection with occasional movement capability.

Armour Wire Specifications:
• Configuration: 7-wire strands (concentric helical winding)
• Wire Diameters:
  – 4×2.5mm² to 4×4mm²: 7/0.45 mm
  – 4×6mm² to 4×16mm²: 7/0.71 mm
  – 4×25mm² to 4×120mm²: 7/0.90 mm
  – 4×150mm²: 7/1.25 mm
• Galvanization: Hot-dip zinc ≥40 g/m²
• Material: Low-carbon steel (350-550 N/mm² tensile)
• Coverage: ≥85% mechanical protection

The armour provides dual functionality in Type 21 cables: primary mechanical protection and secondary earth fault current path in parallel with the dedicated copper earth conductor.

6 OUTER SHEATH – Heavy Duty Chloroprene (Polychloroprene)

The heavy-duty chloroprene outer sheath provides comprehensive environmental protection. According to Tratos Cable Academy, chloroprene offers self-extinction properties, excellent resistance to solvents and oils, and superior weathering characteristics—qualities specifically mandated for colliery trailing cables.

Outer Sheath Thickness:
• 4×2.5mm² to 4×4mm²: 2.5 mm
• 4×6mm² to 4×16mm²: 3.8-3.9 mm
• 4×25mm² to 4×50mm²: 4.3-5.1 mm
• 4×70mm² to 4×120mm²: 5.7-6.8 mm
• 4×150mm²: 7.3 mm

Performance Characteristics:
• Tensile Strength: 10-15 MPa (minimum)
• Elongation at Break: 300-400%
• Abrasion Resistance: Superior to natural rubber
• Temperature Range: -40°C to +120°C (intermittent)
• Oil Resistance: Good (mineral oils and greases)
• Flame Retardance: Self-extinguishing (EN 60332-1-2)

Dimensional Specifications and Physical Parameters

The dimensional specifications of BS 6708 Type 21 cables reflect the enhanced construction required for four-core armoured mining cables. The following comprehensive table presents complete dimensional data:

Cross Section
(mm²)
CoresStranding
(mm)
Conductor
Dia. (mm)
Insulation
Thick. (mm)
Inner Sheath
(mm)
Armour
Size
Outer Sheath
(mm)
Max. OD
(mm)
Min. Bend
Radius (mm)
4×2.54×2.550/0.252.101.42.07/0.452.528.6258
4×44×456/0.302.701.42.07/0.452.530.1271
4×64×684/0.303.301.52.57/0.713.838.8350
4×104×1080/0.404.401.52.57/0.713.841.0369
4×164×16126/0.405.501.52.57/0.713.944.0396
4×254×25196/0.407.101.62.57/0.904.349.8449
4×354×35276/0.408.401.62.57/0.904.756.1505
4×504×50396/0.4010.101.72.57/0.905.161.8557
4×704×70360/0.5011.901.82.57/0.905.771.4643
4×954×95475/0.5013.902.03.87/0.906.378.6708
4×1204×120629/0.5015.802.23.87/0.906.889.0801
4×1504×150740/0.5017.002.35.07/1.257.395.3858

Weight and Material Analysis

Cross Section
(mm²)
Cable Weight
(kg/km)
Copper Weight
(kg/km)
Copper %
of Total
Weight per
100m (kg)
Cost Implication
(Relative)
4×2.51,150968.3%115Base
4×41,32015411.7%1321.15×
4×62,3502309.8%2352.04×
4×102,74038414.0%2742.38×
4×163,17061419.4%3172.76×
4×254,03096023.8%4033.50×
4×355,2201,34425.7%5224.54×
4×506,4001,920*30.0%6405.57×
4×708,0602,68833.4%8067.01×
4×9510,6503,64834.3%1,0659.26×
4×12013,4504,60834.3%1,34511.70×
4×15015,3005,76037.6%1,53013.30×

*Note: 4×50mm² copper weight appears to have a typo in source data (192 kg/km); estimated value of 1,920 kg/km used based on scaling.

Dimensional Analysis

Minimum Bending Radius Formula:
Rmin ≈ 9 × Doverall

Examples:
• 4×25mm²: 449mm ÷ 49.8mm = 9.0×
• 4×95mm²: 708mm ÷ 78.6mm = 9.0×
• 4×150mm²: 858mm ÷ 95.3mm = 9.0×

The consistent 9× ratio ensures uniform mechanical protection across all cable sizes, preventing conductor strand breakage, armour distortion, and insulation damage.

Electrical Characteristics and Performance Parameters

The electrical performance specifications of BS 6708 Type 21 cables are meticulously engineered to ensure reliable power transmission in demanding mining applications while providing enhanced earth fault protection through the dedicated fourth conductor:

Cross Section
(mm²)
Continuous Current
Rating @ 25°C (A)
Conductor
Resistance (Ω/km)
Armour
Resistance (Ω/km)
Effective Earth
Resistance (Ω/km)*
Earth Fault
Advantage
4×2.5288.214.22.7833.8% lower
4×4375.093.92.2143.3% lower
4×6463.392.01.2637.0% lower
4×10631.951.90.9649.5% lower
4×16851.241.70.7257.6% lower
4×251100.7951.50.5265.3% lower
4×351350.5651.10.3766.4% lower
4×501700.3930.960.2870.8% lower
4×702050.2770.800.2173.8% lower
4×952500.2100.730.1678.1% lower
4×1202950.1640.470.1274.5% lower
4×1503200.1320.410.1075.6% lower

*Effective Earth Resistance calculated as parallel combination of conductor and armour: Reff = (Rcond × Rarmour) ÷ (Rcond + Rarmour)

Earth Fault Current Analysis

Earth Fault Current Comparison (95mm² cable, 200m length):

Type 20 (3-core, armour only):
Armour resistance: 0.80 Ω/km × 0.2km = 0.16 Ω
Phase resistance: 0.210 Ω/km × 0.2km = 0.042 Ω
Loop resistance: 0.16 + 0.042 = 0.202 Ω
Fault current (640V phase): 640 ÷ 0.202 = 3,168A

Type 21 (4-core, parallel paths):
Effective earth: 0.16 Ω/km × 0.2km = 0.032 Ω
Phase resistance: 0.210 Ω/km × 0.2km = 0.042 Ω
Loop resistance: 0.032 + 0.042 = 0.074 Ω
Fault current (640V phase): 640 ÷ 0.074 = 8,649A

Improvement: 173% higher fault current for faster protective device operation

Voltage Drop Calculations

For Type 21 cables, voltage drop can be calculated using standard three-phase formula. Since all four conductors have identical construction, the fourth earth conductor has the same resistance as phase conductors:

ΔV = √3 × I × L × (R × cos φ + X × sin φ)

Where X (reactance) ≈ 0.08 Ω/km for mining cables. For typical power factor of 0.85:

Voltage Drop Example:
Cable: 4×70mm², Length: 150m, Load: 180A, pf = 0.85

R = 0.277 Ω/km × 0.15 km = 0.0416 Ω
X = 0.08 Ω/km × 0.15 km = 0.012 Ω
cos φ = 0.85, sin φ = 0.527

ΔV = 1.732 × 180 × (0.0416 × 0.85 + 0.012 × 0.527)
ΔV = 311.8 × (0.0354 + 0.0063)
ΔV = 311.8 × 0.0417 = 13.0V

Percentage drop = (13.0 ÷ 1100) × 100 = 1.18%
Well within 5% limit for mining motor circuits.

Temperature Derating Factors

Current ratings assume 25°C ambient temperature. Apply derating factors for elevated temperatures:

Ambient Temp. (°C)Derating Factor4×95mm² Rated (A)4×150mm² Rated (A)
25 (reference)1.00250320
350.94235301
450.87218278
550.79198253
650.71178227
750.61153195

Short-Circuit Withstand Capability

Adiabatic Equation for I²t Calculation:
I²t = K² × S²
Where K = 143 for EPR insulated copper (90°C to 200°C)

Maximum Short-Circuit Currents (1-second duration):
• 4×25mm²: √(143² × 25²) = 3,575A
• 4×70mm²: √(143² × 70²) = 10,010A
• 4×120mm²: √(143² × 120²) = 17,160A
• 4×150mm²: √(143² × 150²) = 21,450A

Standards Compliance and Certification

Primary Standard: BS 6708:1998

According to Standards.ie BS 6708:1998 documentation, Type 21 cables fall under Section 7: “Cables with galvanized steel pliable wire armouring, rated voltages up to 1900/3300V (types 20, 21, 62, 63, 70, 71, 201, 211, 321 and 331).”

BS 6708 Standard Structure:
• Section 7: Steel pliable wire armoured cables
• Voltage Rating: 640/1100V (U₀/U)
• Test Voltage: 3kV AC
• Core Configuration: Type 21 = 4 unscreened cores
• Application: Explosive atmospheres (IEC 29.260.20)

Supporting Annexes:
• Annex A: Approved codes of practice
• Annex B: Recommended current ratings
• Annex C: Short-circuit current capability

Referenced International Standards

StandardTitleApplication
IEC 60228Conductors of insulated cablesClass 5 flexible conductor requirements
IEC 60724Short-circuit temperature limits200°C maximum for EPR (5 sec)
BS 7655-1.2Elastomeric insulating compoundsEPR compound specifications
BS 7655-2.3Elastomeric sheathing compoundsChloroprene sheath requirements
EN 60332-1-2Flame propagation testSingle cable vertical flame test
IEC 60502-1Power cables 1kV to 3kVGeneral construction requirements

Testing and Certification Requirements

Type Tests (Design Qualification):
☐ Conductor resistance verification (IEC 60228 Class 5)
☐ Voltage withstand: 3kV AC for 5 minutes
☐ Insulation resistance: ≥100 MΩ·km @ 20°C
☐ Partial discharge: <10 pC @ 1.5 × U₀
☐ Bending test: Minimum radius compliance
☐ Hot set test: EPR cross-linking verification
☐ Tensile/elongation: EPR and chloroprene
☐ Armour galvanization: ≥40 μm zinc coating
☐ Flame retardance: EN 60332-1-2 pass
☐ Core identification: Color coding verification
Routine Tests (Production QC):
☐ Conductor resistance per unit length
☐ High-voltage test @ 3kV AC
☐ Insulation resistance (each core to armour)
☐ Armour continuity verification
☐ Earth conductor identification (green/yellow)
☐ Dimensional compliance check
☐ Visual inspection for defects

Comparison with VDE 0250-812 German Standard

Understanding the relationship between BS 6708 Type 21 and German DIN VDE 0250 Part 812 mining cables enables proper cable selection for international mining operations:

BS 6708 Type 21

  • ✓ Rated Voltage: 640/1100V
  • ✓ Cores: 4 (3P + 1E)
  • ✓ Insulation: EPR
  • ✓ Protection: Galvanized steel pliable armour
  • ✓ Sheath: Heavy-duty chloroprene
  • ✓ Temperature: -20°C to +85°C
  • ✓ Short-Circuit: 200°C (5 sec)
  • ✓ Test Voltage: 3kV
  • ✓ Earth System: Dedicated Cu + armour parallel
  • ✓ Armour Configuration: 7-wire strands

VDE 0250-812 NSSHÖU

  • ✓ Rated Voltage: Up to 450/750V
  • ✓ Cores: Various configurations
  • ✓ Insulation: EPR (compound 3GI3)
  • ✓ Protection: Optional armour
  • ✓ Sheath: Chloroprene (compound 5GM5)
  • ✓ Temperature: -40°C to +80°C
  • ✓ Short-Circuit: 250°C
  • ✓ Test Voltage: 2-3kV
  • ✓ Earth System: Concentric monitoring conductor
  • ✓ Armour Configuration: Steel/Cu braid (if equipped)

Key Technical Differences

Voltage Rating Comparison

BS 6708 Type 21’s 640/1100V rating versus VDE 0250-812’s 450/750V provides:

Power Transmission Efficiency:
For 150kW motor load (pf = 0.85):

At 750V (VDE):
I = 150,000 ÷ (1.732 × 750 × 0.85) = 135.8A
Requires 70mm² cable (rated 205A)

At 1100V (BS 6708):
I = 150,000 ÷ (1.732 × 1100 × 0.85) = 92.6A
Adequate with 50mm² cable (rated 170A)

Result: Potential one size reduction in conductor, saving ~25% in cable cost

Mechanical Protection Philosophy

Type 21 cables feature mandatory galvanized steel pliable wire armour providing:

  • Impact resistance from falling rocks and equipment
  • Crush protection in high-traffic mining areas
  • Rodent and vermin protection
  • Dual earth path (copper conductor + armour parallel)

VDE 0250-812 cables may be unarmoured (NSSHÖU) for maximum flexibility, or include optional armour configurations. According to DIN Media, DIN VDE 0250-812 specifies rubber insulated flexible cables NSSHÖU optimized for trailing applications requiring maximum flexibility rather than armoured protection.

Earth Conductor Configuration

FeatureBS 6708 Type 21VDE 0250-812 NSSHCGEÖU
Earth ConductorFull-size copper (same as phase)Concentric monitoring conductor
Earth PathParallel: Cu core + steel armourConcentric PE + steel/Cu braid
MonitoringResistance measurementDedicated pilot cores available
Fault CurrentHigh (full conductor capacity)Variable (depends on configuration)

Application Suitability

Choose BS 6708 Type 21 when:

  • Maximum mechanical protection required
  • Regulations mandate separate earth conductor
  • Highest earth fault current capacity needed
  • 1000V distribution systems utilized
  • British/Commonwealth mining regulations apply

Choose VDE 0250-812 when:

  • Maximum flexibility for continuous reeling required
  • Continuous earth monitoring via pilot cores needed
  • Extreme cold operation (-40°C) anticipated
  • Weight minimization critical
  • European regulatory compliance mandatory

Safety Thresholds and Critical Precautions

⚠️ CRITICAL SAFETY WARNING

BS 6708 Type 21 cables operate in potentially explosive atmospheres. Improper installation, operation, or maintenance can result in ignition of flammable gases, fires, electrical shock fatalities, or catastrophic equipment damage. All work must be performed by competent personnel in accordance with applicable mining safety legislation, manufacturer specifications, and local electrical codes.

Electrical Safety Parameters

Voltage Withstand and Safety Margins

Voltage Safety Analysis:
• Rated Voltage: 640/1100V (U₀/U)
• Test Voltage: 3,000V AC
• Safety Factor: 3,000 ÷ 1,100 = 2.73×

This margin accommodates:
• Switching transients (up to 2× nominal)
• Lightning-induced surges
• Motor starting effects
• Insulation degradation over service life
• Manufacturing tolerances

Overcurrent Protection Requirements

Maximum Conductor Temperature: 90°C
Exceeding this temperature causes:
• Accelerated insulation aging (halved life per 10°C increase)
• Thermal expansion stress on terminations
• Fire risk in cable assemblies
• Bedding compound softening

Protection Device Coordination:
• 120% rated current: Operate <2 hours
• 150% rated current: Operate <30 minutes
• 200% rated current: Operate <2 minutes
• 500% rated current: Operate <10 seconds

Earth Continuity Verification

The dedicated fourth earth conductor provides enhanced safety verification:

Earth Path Resistance Testing:
Type 21 Advantage: Two independent earth paths can be verified:
1. Copper earth conductor: Direct continuity test
2. Steel armour: Resistance measurement
3. Combined effectiveness: Parallel path calculation

Example (4×95mm², 300m run):
• Earth conductor: 0.210 Ω/km × 0.3 = 0.063 Ω
• Armour: 0.73 Ω/km × 0.3 = 0.219 Ω
• Parallel: (0.063 × 0.219) ÷ (0.063 + 0.219) = 0.049 Ω

Total earth loop impedance (including source): ~0.15 Ω
Earth fault current: 640 ÷ 0.15 = 4,267A
Protective device operating time: <0.1 second

Mechanical Safety Thresholds

Bending Radius Compliance

⚠️ BENDING RADIUS VIOLATION CONSEQUENCES:
Exceeding minimum bending radius (258mm to 858mm) causes:
• Immediate: Conductor strand breakage, armour wire distortion
• Progressive: Water ingress, insulation damage, increased resistance
• Catastrophic: Phase-to-earth faults, cable fires, explosions

Critical Points:
• Cable drum winding
• Route changes around obstructions
• Entry to termination boxes
• Support structure transitions

Installation Temperature Restrictions

CRITICAL: Cables must NOT be installed:
• Below 5°C: EPR and chloroprene become brittle, risking cracking
• Above 60°C: Materials become too soft, causing permanent deformation

Pre-condition cables stored in cold environments before installation. Allow cables stored in hot conditions to cool before handling.

Explosive Atmosphere Compliance

Hazardous Area Requirements:
Type 21 cables for explosive atmospheres must comply with:
• Zone classification (Zone 1, 2 for gas; Zone 21, 22 for dust)
• Temperature class limitations (T1-T6)
• Equipment protection concepts (Ex d, Ex e, Ex ia/ib)
• Certified cable glands and terminations

Maximum Surface Temperature:
With 90°C conductor rating and appropriate derating:
• T4 classification (135°C): Compliant
• T5 classification (100°C): Marginal—verify sheath temperature
• T6 classification (85°C): May require additional derating

Installation Guidelines and Best Practices

Pre-Installation Verification

Pre-Installation Checklist:
☐ Verify cable drum condition (no damage, proper rotation direction)
☐ Inspect outer sheath for cuts, abrasions, deformation
☐ Check armour continuity with low-resistance ohmmeter
☐ Measure insulation resistance (each core to armour, core to core)
☐ Verify ambient temperature within 5°C-60°C range
☐ Confirm cable specification matches design requirements
☐ Review route for bending radius compliance
☐ Ensure proper equipment for cable weight handling
☐ Verify earth conductor identification (green/yellow marking)

Cable Handling and Pulling

Weight Considerations

Type 21 cables are significantly heavier than equivalent unarmoured cables:

Handling Equipment Requirements:
• 4×25mm²: 100m = 403 kg—Manual handling possible with team
• 4×70mm²: 100m = 806 kg—Mechanical assistance required
• 4×120mm²: 100m = 1,345 kg—Heavy lifting equipment mandatory
• 4×150mm²: 100m = 1,530 kg—Crane or specialized drum trailer required

Cable drums may weigh 2-5 tonnes total with cable and drum weight.

Maximum Pulling Force

Fmax = k × n × S × σ

Where k = 0.5 (safety factor), n = 4 (all conductors), S = cross-section, σ ≈ 200 N/mm²

Maximum Pulling Forces (All 4 Conductors):
• 4×25mm²: F = 0.5 × 4 × 25 × 200 = 10,000 N
• 4×70mm²: F = 0.5 × 4 × 70 × 200 = 28,000 N
• 4×120mm²: F = 0.5 × 4 × 120 × 200 = 48,000 N
• 4×150mm²: F = 0.5 × 4 × 150 × 200 = 60,000 N

Termination and Bonding Procedures

Four-Core Termination

  1. Strip outer chloroprene sheath (150-250mm)
  2. Clean and prepare armour wires for gland retention
  3. Install appropriate armoured cable gland with compression cone
  4. Bond gland to earth bar (minimum 10mm² bonding conductor)
  5. Identify earth core (green/yellow) and verify continuity
  6. Connect phase conductors with proper phase rotation
  7. Connect earth conductor to equipment earth terminal
  8. Apply heat-shrink boots for moisture sealing
  9. Torque all connections to manufacturer specifications

Armour and Earth Bonding

Dual Earth Path Bonding:
Both earth paths must be properly bonded:
1. Copper earth conductor: Connected to equipment earth terminal
2. Steel armour: Bonded via cable gland to earth bar

Both paths should be tested independently before energization. Total earth loop impedance must be verified for protective device coordination.

Post-Installation Testing

Commissioning Test Sequence:
1. Visual Inspection: Route compliance, gland tightness, identification
2. Continuity Test: All four conductors plus armour bond
3. Earth Conductor Verification: Dedicated earth path continuity
4. Insulation Resistance: Phase-to-phase, phase-to-earth, phase-to-armour
   • Minimum acceptable: 1 MΩ
   • Typical new cable: 100-1000 MΩ
5. Earth Loop Impedance: Both paths (conductor and armour)
6. Phase Rotation Test: Confirm correct sequence for motor loads
7. Documentation: Record all test results for future reference

Common Problems and Frequently Asked Questions

Q1: Why choose Type 21 over Type 20 if both meet BS 6708?

Answer: Type 21 provides several critical advantages:

  • Enhanced earth fault protection: 65-78% lower effective earth resistance through parallel paths
  • Regulatory compliance: Some jurisdictions mandate separate earth conductors
  • Simplified testing: Dedicated earth conductor easier to verify than armour resistance
  • Higher fault currents: Up to 173% higher fault current for faster protective device operation
  • Insurance requirements: Some insurers require four-core cables for critical equipment

The additional cost (approximately 20-30% weight increase) is justified for safety-critical applications.

Q2: Can the fourth core be used for purposes other than earth?

Answer: No. The fourth core is specifically designated as earth conductor (green/yellow identification) and must not be used for:

  • Neutral conductor (star-connected loads)
  • Control signals
  • Pilot wire monitoring
  • Additional power circuit

Using the earth conductor for other purposes violates safety standards and creates serious electrical hazards. For applications requiring neutral, pilot cores, or additional conductors, select appropriate cable types (e.g., Type 506/512/518/524 for multi-core applications).

Q3: What causes armour corrosion in Type 21 cables?

Answer: Common causes include:

  • Moisture ingress: Through damaged sheath or poor terminations
  • Galvanic corrosion: Contact between steel armour and copper earth conductor at terminations
  • Acidic mine water: Chemical attack on zinc galvanization
  • Mechanical damage: Abrasion removing protective coating

Prevention measures:

  • Use IP68-rated cable glands with proper sealing
  • Apply anti-oxidant compound at terminations
  • Install cables above water levels where possible
  • Regular visual inspections for sheath damage
  • Use bi-metallic separators at copper/steel interfaces

Q4: How do I size the cable for a specific motor load?

Answer: Follow this sizing procedure:

Cable Sizing Example:
Motor: 110kW, 1000V, 3-phase, pf = 0.85, eff = 0.92
Cable length: 250m
Ambient temperature: 40°C

Step 1: Calculate full load current
IFL = 110,000 ÷ (1.732 × 1000 × 0.85 × 0.92) = 81.3A

Step 2: Apply derating factor
At 40°C: Factor = 0.91
Required rating: 81.3 ÷ 0.91 = 89.3A

Step 3: Select cable
4×25mm² rated 110A (inadequate margin)
4×35mm² rated 135A (adequate margin)
Select: 4×35mm²

Step 4: Verify voltage drop
ΔV = 1.732 × 81.3 × 0.25 × 0.565 = 19.9V
Percentage: (19.9 ÷ 1000) × 100 = 2.0% ✓

Q5: What maintenance schedule is recommended for Type 21 installations?

Answer: Recommended intervals based on environment severity:

Inspection TypeNormal EnvironmentSevere Environment
Visual inspectionMonthlyWeekly
Termination temperature (IR)QuarterlyMonthly
Earth continuity (Cu conductor)Semi-annuallyQuarterly
Insulation resistance testAnnuallySemi-annually
Complete electrical testingEvery 3 yearsAnnually
Armour condition assessmentAnnuallySemi-annually

Q6: Can Type 21 cables be spliced in the field?

Answer: Field splicing is strongly discouraged due to:

  • Difficulty maintaining armour protection integrity at splice
  • Risk of moisture ingress and insulation failure
  • Earth conductor continuity may be compromised
  • Regulatory restrictions in hazardous areas
  • Warranty and liability implications

If absolutely necessary, use only approved armoured cable joint kits specifically designed for four-core mining cables, and ensure full compliance with local mining electrical regulations. Cable replacement is generally preferred over field repair.

Q7: What is the expected service life of Type 21 cables?

Answer: Under proper installation and maintenance conditions:

  • Fixed installation: 20-30 years typical life expectancy
  • Semi-mobile installation: 10-15 years with periodic movement
  • Frequent relocation: 5-10 years due to mechanical fatigue

Factors affecting service life:

  • Operating temperature (every 10°C above 90°C halves life)
  • Mechanical stress (flexing, crushing, abrasion)
  • Chemical exposure
  • Moisture ingress
  • Overcurrent events
  • Quality of installation and terminations

Contact Anhui Feichun Special Cable Co., Ltd.

For technical inquiries, product specifications, quotations, and custom cable requirements for BS 6708 Type 21 four-core mining cables and other specialized mining cable solutions, please contact our expert engineering team:

📧
Technical Support:
[email protected]
📧
Sales Department:
[email protected]
📱

Anhui Feichun Special Cable Co., Ltd. (安徽飞纯特种电缆有限公司) specializes in manufacturing high-quality mining cables, armoured trailing cables, and specialty cables for demanding industrial applications. Our products comply with international standards including BS 6708, AS/NZS 2802, VDE 0250, and SANS 1520, serving mining operations worldwide with comprehensive technical support and custom cable solutions.

References and External Technical Resources

Anhui Feichun Special Cable Co., Ltd. | 安徽飞纯特种电缆有限公司

Professional Mining Cable Solutions | BS 6708 | AS/NZS 2802 | VDE 0250 | SANS 1520

© 2025 Feichun Cables. All technical information provided for educational and reference purposes. Always consult local mining electrical regulations and qualified professional engineers for specific installations.

Previous Article

What is Type 20 BS 6708 Mining Cable?

Next Article

ANSI/NEMA WC 58 / ICEA S-75-381: Portable and Power Feeder Cables for Mining Applications

View Comments (1)