What is UNE 22512:1996 Flexible Armored Mining Cables?

Comprehensive Technical Guide to Spanish Standard for Type DM2N Flexible Armored Cables for Underground Mining

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
What is UNE 22512:1996 Flexible Armored Mining Cables Type DM2N? | Complete Technical Guide 2025

What is UNE 22512:1996 Flexible Armored Mining Cables?

Comprehensive Technical Guide to Spanish Standard for Type DM2N Flexible Armored Cables for Underground Mining

🔌 Anhui Feichun Special Cable Co., Ltd. (安徽飞纯特种电缆有限公司)

Specialized Manufacturer of UNE 22512 Compliant Flexible Armored Mining Cables – Expert in Type DM2N EPR insulated cables for mobile mining equipment and trailing applications

1. Introduction to UNE 22512:1996 Flexible Armored Mining Cables

UNE 22512:1996 is a specialized Spanish national standard published by AENOR (Spanish Association for Standardization and Certification) that specifically addresses flexible armored cables with EPR insulation for underground mining applications. This standard defines comprehensive requirements for cables rated from 0.6/1 kV to 3.6/6 kV designated as Type DM2N, engineered for mobile mining equipment subjected to extreme mechanical stress.

🎯 Standard Overview:

  • Standard Designation: UNE 22512:1996
  • Full Title: Electric Cables for Underground Mining – Flexible Armored Cables – EPR Insulated – Nominal Voltage 0.6/1 kV to 3.6/6 kV – Type DM2N
  • Spanish Title: Cables eléctricos para interior de minas – Cables flexibles armados aislados con EPR – Tensión nominal 0,6/1 kV a 3,6/6 kV – Tipo DM2N
  • Publication Date: 1996
  • Issuing Body: AENOR (Spanish Association for Standardization and Certification)
  • ICS Classification: 29.060.20 (Cables) and 73.100.99 (Other mining equipment)
  • Related Standards: UNE 22510 (General), UNE 22511 (Rigid Armored), UNE 22513 (Flexible Non-Armored)

1.1 Key Distinctions from Other UNE Mining Cable Standards

UNE 22512 is part of the comprehensive UNE 22510 family of mining cable standards but focuses specifically on cables requiring both flexibility and mechanical armor protection:

📘 UNE 22510:1996
General Requirements
Foundation standard covering all underground mining cables – insulation types, screening, armor classifications, and designation systems
📗 UNE 22511:1996
Rigid Armored Cables
Fixed installation cables with heavy-duty steel wire armor for permanent underground distribution (Type VVMV)
📕 UNE 22512:1996
Flexible Armored Cables
Mobile equipment cables with flexible steel wire armor and EPR insulation for trailing applications (Type DM2N) – This Standard
📙 UNE 22513:1996
Flexible Non-Armored Cables
Highly flexible cables without mechanical armor for protected environments and reeling applications (Type DN)

1.2 Why UNE 22512 Matters for Modern Mining

According to research from mining cable specialists, flexible armored cables represent a critical solution where cables must simultaneously endure severe mechanical abuse while maintaining electrical flexibility for mobile equipment. The unique construction specified in UNE 22512 addresses this dual requirement through specialized flexible steel wire armor combined with EPR insulation’s superior flexibility characteristics.

Modern underground mining operations demand cables that can withstand:

  • Continuous Flexing: Daily bending cycles as equipment moves through galleries
  • Abrasion Resistance: Contact with rocks, machinery, and rough mine floor surfaces
  • Crush Protection: Resistance to compression from equipment wheels and falling debris
  • Chemical Exposure: Diesel fuel, hydraulic oils, mine water, and cleaning agents
  • Temperature Extremes: From frozen surface conditions to hot underground environments
  • Explosion Hazards: Safe operation in potentially explosive methane atmospheres

2. Purpose and Applications of UNE 22512 Flexible Armored Cables

2.1 Primary Design Purpose

UNE 22512 Type DM2N cables are specifically engineered for trailing cable applications where electrical power must follow mobile mining equipment throughout underground workings. The standard addresses the unique challenge of providing both electrical flexibility (for movement) and mechanical protection (for abuse resistance) in a single cable design.

🔧 Engineering Challenge Solved:

Traditional Trade-off: Standard cables are either flexible (but vulnerable to mechanical damage) or armored (but too stiff for trailing applications). UNE 22512 specifies a construction using flexible galvanized steel wire cable armor that maintains 80-85% of the cable’s flexibility while providing near-rigid armor levels of protection.

2.2 Specific Mining Applications

Equipment TypeCable FunctionTypical VoltageMovement PatternKey Requirements
Continuous MinersMain power supply trailing cable0.6/1 kV or 3.6/6 kVFrequent forward/reverse, 100-500m cable deploymentHigh flex life, abrasion resistance, flame retardancy
Shuttle CarsMobile power and control cable0.6/1 kVContinuous movement, cable draggingExtreme abrasion resistance, crush protection
Roof BoltersPower and hydraulic control circuits0.6/1 kVFrequent repositioning, overhead workFlexibility, cut resistance, flame retardancy
Load-Haul-Dump (LHD) VehiclesMain power trailing cable0.6/1 kVHeavy duty cycles, long cable runsHigh tensile strength, impact resistance
Mobile DrillsPower supply for drilling equipment0.6/1 kV or 3.6/6 kVFrequent setup/takedown cyclesTorsion resistance, vibration tolerance
Mobile PumpsSubmersible pump power cables0.6/1 kVSemi-permanent with occasional relocationWater immersion resistance, armor protection
Cutting MachinesHigh-power motor supply cables3.6/6 kVSlow advance during cutting operationsHigh voltage insulation, mechanical protection

2.3 Operational Environments

Insights from specialized reeling cable manufacturers emphasize that UNE 22512 cables must function reliably in diverse underground mining conditions:

⛏️
Coal Mines
Methane-rich atmospheres, coal dust, high fire risk, strict flame retardancy requirements, ground-check monitoring mandatory
💎
Hard Rock Mining
Extremely abrasive environment, sharp rock surfaces, high mechanical stress, crushing hazards from rockfall
🏔️
Deep Underground Operations
High ambient temperatures (40-50°C), high humidity (95-100%), corrosive groundwater, elevated rock stress
🏗️
Quarries and Open Pit
UV exposure, temperature cycling (-30°C to +60°C), water immersion, diesel contamination, heavy equipment traffic

2.4 Trailing vs. Reeling Cable Applications

🚜 Trailing Cable Application

Configuration: Cable lies on mine floor, dragged behind equipment

Movement: Slides and flexes as equipment moves

Primary Stress: Abrasion, crushing, repeated flexing

UNE 22512 Advantage: Flexible armor provides excellent protection against floor abrasion and crush loads while maintaining sufficient flexibility for movement

Typical Applications: Continuous miners, shuttle cars, mobile drills

🎡 Reeling Cable Application

Configuration: Cable wound on motorized or spring-loaded reel

Movement: Automatically winds/unwinds as equipment travels

Primary Stress: Constant flexing, torsion, tension cycling

Design Consideration: UNE 22512 cables can be used for light reeling applications, but specialized reeling cables (per reeling cable specifications) are preferred for intensive duty cycles

Typical Applications: Cable reelers on excavators, gantry cranes, mobile substations

3. Technical Characteristics of UNE 22512 Cables

3.1 Electrical Performance Parameters

Parameter0.6/1 kV Rating3.6/6 kV RatingTest Standard
Nominal Voltage U₀/U0.6/1 kV3.6/6 kVIEC 60038
AC Test Voltage (5 min)3,500 V11,000 VUNE 22512 § 8.3
Maximum Conductor Temperature90°C (EPR continuous rating)90°C (EPR continuous rating)IEC 60502-1
Short-Circuit Temperature (≤5 sec)250°C250°CIEC 60364-5-52
Operating Temperature Range (Fixed)-20°C to +85°C-20°C to +85°CUNE 22512
Operating Temperature Range (Flexible)-5°C to +85°C-5°C to +85°CUNE 22512
Installation Temperature (Minimum)-5°C-5°CDIN VDE 0298-3
Minimum Bend Radius (Fixed Installation)10 × outer diameter10 × outer diameterUNE 22512 Table 4
Minimum Bend Radius (Flexible Operation)10 × outer diameter10 × outer diameterUNE 22512 Table 4
Insulation Resistance (Initial)≥20 MΩ @ 500V DC≥50 MΩ @ 1000V DCIEC 60502-1

3.2 Mechanical Performance Characteristics

According to Australian mining cable specialists, flexible armored cables must meet stringent mechanical performance criteria to ensure reliability in demanding underground environments:

🏋️ Superior Mechanical Properties:

  • Water Resistance Rating: AD5 (Water jets from any direction) per IEC 60529 – suitable for wet mine galleries and pump applications
  • Impact Resistance Rating: AG4 (Very strong – reinforced for severe industrial use) – withstands falling rocks and equipment impacts
  • Oil Resistance: Tested per EN 60811-2-1 – resistant to diesel fuel, hydraulic fluids, and mineral oils
  • Abrasion Resistance: Polychloroprene sheath exceeds 200 cycles per DIN EN 50396 abrasion test
  • Tensile Strength (Sheath): Minimum 15 N/mm² ensures structural integrity
  • Elongation at Break (Sheath): Minimum 300% provides excellent flexibility and tear resistance
  • Crush Resistance: Armor withstands 1000 N/cm width without conductor damage
  • Flex Life: Minimum 500,000 flex cycles at 10× diameter bend radius before conductor failure
  • Torsion Resistance: ±180° twist per meter without permanent deformation or performance degradation

3.3 EPR Insulation Advantages

UNE 22512 mandates Ethylene Propylene Rubber (EPR) insulation specifically for its superior performance in mining environments:

PropertyEPR PerformanceAdvantage for MiningTest Standard
Flexibility at Low TemperaturesRemains flexible down to -25°CEssential for surface-to-underground transitions, cold storage areasDIN VDE 0207-20
Heat ResistanceContinuous 90°C, emergency 105°C, short-circuit 250°CHigher ampacity, overload tolerance, longer service lifeIEC 60502-1
Ozone ResistanceExcellent – no cracking after 168h @ 50°CProtection from ozone generated by electrical arcing and weldingIEC 60811-2-1
Weather ResistanceUV-stable, moisture-resistantSuitable for quarries, open-pit operations, outdoor storageEN ISO 4892-2
Water ResistanceNon-hygroscopic, no water treeingMaintains insulation integrity in wet underground conditionsIEC 60502-2
Flame RetardancySelf-extinguishing, low smoke emissionCritical for coal mines, reduces fire propagation riskEN 60332-1-2
Mechanical FlexibilityMaintains flexibility through service lifeEnables trailing applications, reduces cable fatigueDIN VDE 0295
Chemical ResistanceResistant to acids, alkalis, oilsProtection from mine chemicals, cleaning agents, fuel spillsEN 60811-2-1

3.4 Fire Safety Performance

Fire safety is paramount in confined underground environments. UNE 22512 cables must meet rigorous flame retardancy standards:

Fire TestStandardRequirementMining Relevance
Single Cable Vertical Flame TestEN 60332-1-2 / IEC 60332-1-2 / VDE 0482-332-1-2Self-extinguishing within 60 seconds, no flame spread beyond 540mmPrevents single cable ignition from propagating
Bundled Cable Flame TestEN 60332-3-24 / IEC 60332-3-24 (Category C)Limited flame propagation in cable bundlesCritical for cable galleries and grouped installations
Smoke Emission TestEN 61034-2 / IEC 61034-2Light transmittance ≥60% during combustionMaintains visibility for emergency evacuation
Corrosive Gas EmissionEN 60754-2 / IEC 60754-2pH ≥4.3, conductivity ≤10 μS/mmReduces damage to ventilation systems and equipment

4. Material Structure and Construction Details

4.1 Layer-by-Layer Construction Analysis

UNE 22512 Type DM2N cables feature a sophisticated multi-layer construction designed to balance flexibility with protection. Let’s examine each layer from the inside out:

📐 Complete Cable Cross-Section (Typical DM2N 0.6/1 kV 3×50+3×25 F Construction):

  1. Power Conductors (3×): 50 mm² tinned copper, Class 5 flexible stranding, 396 strands × 0.26mm wire
  2. Protective Earth Conductors (3×): 25 mm² tinned copper, Class 5 flexible, divided into three separate conductors
  3. Conductor Insulation: EPR Type 3GI3, 1.8mm thickness on power conductors, black color
  4. Assembly: Conductors laid up with optimized lay length, cradle separator with textile reinforcement
  5. Inner Covering: Semiconductive rubber filler compound for torsion resistance
  6. Flexible Armor: Galvanized steel wire cables (flexible construction), copper conductance ≥50% of phase conductor
  7. Outer Sheath: Polychloroprene (PCP) Type 5GM5, 3.0mm thickness, black color
  8. Total Outer Diameter: Approximately 48-52mm
  9. Approximate Weight: 6.8-7.5 kg/m

4.2 Conductor Design and Specifications

🔩 Conductor Material
Tinned Copper per IEC 60228 Class 5:
• Ultra-flexible stranding for mobile applications
• Tinning provides corrosion resistance in humid mines
• Individual strand diameter: 0.21-0.31mm depending on conductor size
• Concentric lay construction for optimal flexibility
📏 Standard Conductor Sizes
0.6/1 kV Rating: 16-240 mm²
3.6/6 kV Rating: 35-150 mm²
AWG Equivalents: 6 AWG to 500 MCM
Power Cores: Typically 3-core or 4-core
Earth Cores: 1 to 3 separate conductors
⚡ Conductor Resistance
Maximum DC resistance @ 20°C:
• 16 mm²: 1.15 Ω/km
• 25 mm²: 0.727 Ω/km
• 35 mm²: 0.524 Ω/km
• 50 mm²: 0.387 Ω/km
• 95 mm²: 0.193 Ω/km
• 150 mm²: 0.124 Ω/km
🎨 Conductor Identification
Per UNE 21089-1 and HD 308:
• Phase 1: Brown
• Phase 2: Black
• Phase 3: Grey
• Protective Earth: Yellow-Green
• Pilot Conductors: Black with numbering

4.3 EPR Insulation System

The insulation system is critical for electrical integrity and mechanical flexibility:

Voltage RatingInsulation ThicknessEPR TypeAdditional Layers
0.6/1 kV (16-35 mm²)1.4 mmEPR Type 3GI3 per DIN VDE 0207-20None required
0.6/1 kV (50-95 mm²)1.8 mmEPR Type 3GI3 per DIN VDE 0207-20None required
0.6/1 kV (120-240 mm²)2.2 mmEPR Type 3GI3 per DIN VDE 0207-20None required
3.6/6 kV (35-70 mm²)3.4 mmEPR with semiconductor screensConductor screen + insulation screen (semiconductor tape)
3.6/6 kV (95-150 mm²)3.4 mmEPR with semiconductor screensConductor screen + insulation screen (semiconductor tape)

4.4 Flexible Armor Construction – The Key Innovation

The distinguishing feature of UNE 22512 cables is the flexible galvanized steel wire cable armor. Unlike rigid armor (UNE 22511), this armor is constructed from multiple small-diameter wires formed into cable-like elements:

🔧 Flexible Armor Specifications (Type M2):

  • Construction: Galvanized steel wires formed into flexible cables, applied helically
  • Individual Wire Diameter: 0.4-0.8mm (much smaller than rigid armor’s 1.8-2.5mm wires)
  • Number of Armor Elements: Typically 12-36 individual wire cables depending on cable diameter
  • Armor Lay Direction: Opposite to core lay for mechanical stability
  • Copper Conductance Requirement: Combined copper cross-section ≥50% of phase conductor area
  • Purpose of Copper Content: Provides low-impedance ground path, enhances ground fault protection
  • Galvanization: Hot-dip galvanizing per EN ISO 1461 for corrosion protection
  • Armor Resistance: Maximum 3.0 Ω/km for effective equipment grounding
  • Flexibility Retention: Cable maintains 80-85% of non-armored flexibility
  • Protection Level: Equivalent to AG3/AG4 impact resistance rating

4.5 Outer Sheath Materials

UNE 22512 typically specifies Polychloroprene (PCP) outer sheath for maximum performance:

PropertyPCP PerformanceTest Method
Material TypeType 5GM5 per DIN VDE 0207-21 (Polychloroprene compound)DIN VDE 0207-21
Nominal Thickness2.5-4.0mm depending on cable diameterUNE 22512 Table 3
Color OptionsStandard black, also available in yellow for high-visibility applicationsVisual inspection
Tensile StrengthMinimum 15 N/mm²EN 60811-1-1
Elongation at BreakMinimum 300%EN 60811-1-1
Abrasion Resistance>200 cycles (abrasion blade test)DIN EN 50396
Oil ResistanceMass increase <10% after 7 days @ 70°C in IRM 903 oilEN 60811-2-1
Ozone ResistanceNo cracking after 168h @ 40°C, 100pphm ozoneEN 60811-2-1
Temperature Range-40°C to +85°C operational, -50°C short-term storageDIN VDE 0207-21
Flame RetardancySelf-extinguishing, meets EN 60332-1-2EN 60332-1-2

5. Type DM2N Cable Designation and Variants

5.1 Understanding the DM2N Designation

The designation “DM2N” follows the systematic UNE 22510 cable code structure:

D – M2 – N

D
Insulation Type
EPR
(Ethylene Propylene Rubber)
M2
Armor Type
Flexible Steel Wire Cable
(Galvanized, flexible construction)
N
Outer Sheath
Polychloroprene (PCP)
(Oil and weather resistant)

5.2 Standard DM2N Cable Configurations

According to leading mining cable manufacturers, the most common DM2N configurations include:

Complete DesignationConfiguration BreakdownTypical ApplicationApproximate Weight
DM2N 0.6/1 kV (3×25+3×10) F3× 25mm² power + 3× 10mm² earth, flexible conductorsSmall shuttle cars, roof bolters, light mobile equipment4.2 kg/m
DM2N 0.6/1 kV (3×50+3×25) F3× 50mm² power + 3× 25mm² earth, flexible conductorsMedium continuous miners, LHD vehicles, mobile drills7.5 kg/m
DM2N 0.6/1 kV (3×95+3×50) F3× 95mm² power + 3× 50mm² earth, flexible conductorsLarge continuous miners, heavy mobile pumps, cutting machines13.8 kg/m
DM2N 0.6/1 kV (3×150+3×70) F3× 150mm² power + 3× 70mm² earth, flexible conductorsHigh-power continuous miners, main feeder cables19.5 kg/m
DM2N 3.6/6 kV (3×50) F3× 50mm² power with semiconductor screensMedium voltage mobile transformers, distribution equipment8.2 kg/m
DM2N 3.6/6 kV (3×95) F3× 95mm² power with semiconductor screensHigh voltage continuous miner feeders, mobile substations15.5 kg/m

5.3 DM2N Variants with Pilot Conductors

For equipment requiring remote control or monitoring, DM2N cables can include pilot conductors:

Example: DM2N 0.6/1 kV (3×50+3×25+3×4 P) F

  • Power Conductors: 3× 50mm² tinned copper, EPR insulated
  • Protective Earth: 3× 25mm² tinned copper
  • Pilot Conductors: 3× 4mm² for control signals (marked with “P”)
  • Total Cores: 9 conductors
  • Applications: Automated continuous miners, remote-controlled equipment, monitoring systems
  • Pilot Insulation: EPR, black color with numerical identification
  • Approximate Weight: 8.8 kg/m

6. Compliance with International Standards

6.1 Relationship to Global Standards

While UNE 22512 is a Spanish national standard, it incorporates requirements from numerous international standards to ensure global compatibility:

Standard OrganizationRelevant StandardsAspects Covered
IEC (International)IEC 60228, 60502-1, 60502-2, 60332 series, 60754 series, 61034Conductor specifications, insulation requirements, fire performance, smoke/gas emission
DIN VDE (Germany)DIN VDE 0250-813, 0207 series, 0298-3, 0295Mining cable construction, materials, installation practices, conductor classes
EN (European Union)EN 50525-2-21, 60332-3-24, 60811 series, 50363Flexible cable design, flame spread testing, material testing methods
ICEA (North America)ICEA S-75-381, S-95-658Portable/feeder cable specifications, ampacity calculations
MSHA (USA)30 CFR Part 18, Part 75Mining equipment safety, flame resistance requirements
AS/NZS (Australia/NZ)AS/NZS 1802:2003, 2802:2000Mining reeling cables, trailing cable specifications

6.2 Key Standard Requirements

📘 IEC 60228
Conductor Classification
Defines Class 5 flexible conductor requirements – minimum number of wires, maximum individual wire diameter, resistance limits
📘 IEC 60502-1
Low Voltage Power Cables
Specifies EPR insulation thickness, voltage test requirements, temperature ratings for 0.6/1 kV cables
📘 DIN VDE 0250-813
Mining Cable Construction
German standard providing detailed construction requirements for flexible mining cables, armor specifications
📘 EN 60332-3-24
Vertical Flame Spread
Category C flame propagation test for bundled cables – critical for underground installations

6.3 Quality Management and Certifications

  • ISO 9001:2015 – Quality management system ensuring consistent manufacturing processes and traceability
  • ISO 14001:2015 – Environmental management for sustainable cable production and waste reduction
  • RoHS II Directive 2011/65/EU + Amendment (EU) 2015/863 – Restriction of hazardous substances (lead, mercury, cadmium, etc.)
  • ATEX Certification – For cables used in potentially explosive atmospheres (Ex zones) in coal mines
  • CE Marking – European Conformity declaration for EU market access
  • EAC Certification – Eurasian Conformity for Russian Federation and CIS countries
  • MSHA Approval – If exported to USA, cables may require Mine Safety and Health Administration approval

7. Safety Thresholds and Requirements for UNE 22512 Cables

7.1 Critical Electrical Safety Parameters

Research from international mining cable specialists emphasizes the importance of adhering to strict electrical safety thresholds:

Safety ParameterThreshold ValueMonitoring MethodAction if Exceeded
Insulation Resistance (New Cable)≥20 MΩ @ 500V DC (0.6/1 kV)
≥50 MΩ @ 1000V DC (3.6/6 kV)
Megger testing before installationReject cable, investigate manufacturing defect
Insulation Resistance (In Service)≥1 MΩ @ 500V DC minimumMonthly testing or after suspected damageRemove from service, dry if moisture-related, replace if <1 MΩ persists
Ground Continuity Resistance≤1 Ω end-to-end (armor + earth conductors)Daily before equipment operationDo not operate equipment, inspect connections, repair immediately
Voltage Drop (Operating)≤5% of nominal voltage for 0.6/1 kV
≤3% for 3.6/6 kV
Voltage measurement at equipment terminalsCheck for undersized cable, excessive length, poor connections
Maximum Conductor Temperature90°C continuous, 105°C emergency (15 min)Thermal imaging, embedded temperature sensorsReduce load, investigate overloading or poor connections
Ground Fault CurrentTrip at 30-50 mA for personnel protectionGround fault protection device monitoringAutomatic trip, investigate fault location, repair before re-energizing

7.2 Current Carrying Capacity (Ampacity) Data

Proper cable sizing is essential for safety and performance. Ampacity values for DM2N cables based on EPR insulation (90°C conductor temperature, 30°C ambient):

Conductor SizeCurrent (Single Cable in Air)Current (3 Cables Grouped, 80%)Max Motor Power @ 400V 3-PhaseApprox. Cable Weight
3×16 mm² + 3×8 mm²75 A60 A30 kW3.2 kg/m
3×25 mm² + 3×10 mm²100 A80 A45 kW4.2 kg/m
3×35 mm² + 3×16 mm²125 A100 A55 kW5.5 kg/m
3×50 mm² + 3×25 mm²160 A128 A75 kW7.5 kg/m
3×70 mm² + 3×35 mm²210 A168 A110 kW10.2 kg/m
3×95 mm² + 3×50 mm²260 A208 A150 kW13.8 kg/m
3×120 mm² + 3×70 mm²305 A244 A185 kW17.5 kg/m
3×150 mm² + 3×70 mm²355 A284 A220 kW19.5 kg/m
3×185 mm² + 3×95 mm²415 A332 A260 kW24.8 kg/m
3×240 mm² + 3×120 mm²500 A400 A315 kW31.2 kg/m

Note: Ampacity values based on IEC 60502-1 and ICEA S-75-381. Apply derating factors for: ambient temperature >30°C, cables in conduit, burial depth, soil thermal resistivity, and grouping. Always verify with manufacturer for specific installation conditions.

7.3 Mechanical Safety Limits

⚠️ Critical Mechanical Thresholds:

Mechanical ParameterMaximum AllowableConsequence if Exceeded
Pulling Tension5 kg per mm² of total conductor areaConductor elongation, strand breakage, connection pull-out
Minimum Bend Radius (Installation)10× outer diameterArmor buckling, insulation compression, conductor damage
Minimum Bend Radius (Operation)10× outer diameterAccelerated fatigue, premature failure, armor wire breakage
Crush Load (Transverse)2000 N per cm of cable widthArmor penetration, conductor deformation, insulation damage
Impact Energy20 J at -5°C (drop test)Sheath cracking, armor exposure, water ingress path
Abrasion Cycles>200 cycles (10N blade, 10mm travel)Sheath wear-through, armor exposure, reduced service life
Torsion Limit±180° per meterConductor spiral deformation, core displacement, sheath split

8. Installation and Usage Precautions for DM2N Cables

8.1 Pre-Installation Inspection and Testing

✅ Mandatory Pre-Installation Checks:

  1. Visual Inspection:
    • Examine entire cable length for cuts, abrasions, or sheath damage
    • Verify armor wires are intact with no protruding or broken strands
    • Check cable drum for water infiltration, corrosion, or physical damage
    • Inspect end seals to ensure moisture hasn’t entered conductor core
  2. Electrical Testing:
    • Perform insulation resistance test: minimum 20 MΩ @ 500V DC for 0.6/1 kV cables
    • Test ground continuity: maximum 1 Ω resistance for armor + earth conductors
    • Verify phase-to-phase resistance matches manufacturer specifications (±5%)
    • Document all test results with date, tester name, and equipment serial numbers
  3. Dimensional Verification:
    • Confirm cable type, voltage rating, and conductor sizes match purchase order
    • Measure outer diameter to verify proper cable gland and connector sizing
    • Check cable length against project requirements with 5-10% excess for terminations

8.2 Cable Handling and Storage Best Practices

Proper handling is critical to prevent damage before installation. According to mining cable handling guidelines:

ActivityRequirementsCommon Mistakes to Avoid
Transportation• Secure drums vertically on flatbed trucks
• Use drum brakes to prevent rolling
• Protect from direct sunlight and rain
• Maximum stack height: 2 drums
❌ Horizontal drum storage (causes core deformation)
❌ Removing cable from drum for transport
❌ Dropping or impacting drums
Storage Location• Indoor dry warehouse preferred
• Temperature: +5°C to +40°C
• Relative humidity: <75%
• Well-ventilated area
• No corrosive atmospheres
❌ Outdoor storage without weatherproof cover
❌ Storage near heat sources or in direct sunlight
❌ Damp basements or unventilated areas
Drum Positioning• Drums vertical on flange
• Drum axis horizontal
• Rotation arrow visible
• Clear access for unwinding
❌ Laying drums flat on side
❌ Stacking more than 2 high
❌ Blocking rotation direction arrow
UV Protection• Cover with opaque tarps if stored outdoors
• Maximum outdoor storage: 6 months
• Rotate stock (FIFO – first in, first out)
❌ Long-term outdoor exposure
❌ Clear plastic covers (still allow UV damage)
❌ Storing cables near welding operations

8.3 Installation Procedures

🔧 Step-by-Step Installation Process:

Step 1: Cable Route Planning
  • Survey cable route from power source to equipment location
  • Identify obstacles, sharp corners, potential crush points
  • Plan cable support/protection: cable trays, floor mats, cable bridges
  • Calculate required cable length: actual distance + 10% slack + termination allowances
  • Verify minimum bend radius clearances at all corners (10× cable OD)
Step 2: Cable Laying
  • Never drag cable directly on rough ground – use rollers every 2-3 meters
  • Maintain natural cable lay – do not twist or reverse cable direction
  • Deploy cable slowly – maximum pulling speed 10 m/min
  • Use proper cable grips attached to armor, never pull by outer sheath alone
  • Apply cable pulling lubricant (water-soluble, non-petroleum) if needed
  • Monitor pulling tension – stop if exceeds 5 kg per mm² of conductor area
Step 3: Cable Support and Protection
  • Install cable mats or plastic track in high-traffic areas
  • Use cable bridges at roadway crossings
  • Support cable every 1.5-2 meters in vertical runs to prevent strain
  • Install cable warning signs in areas where personnel may walk
  • Protect cable from sharp edges with rubber boots or armor guards
Step 4: Termination
  • Use only approved cable glands rated for mining use (IP66/IP67 minimum)
  • Maintain armor electrical continuity – bond armor to equipment ground
  • Install proper strain relief – cable clamp or gland must support full cable weight
  • Seal all entries against moisture with heat-shrink boots or mastic sealant
  • Color-code and label all connections per electrical code
  • Torque all connections to manufacturer specifications using calibrated torque wrench
  • Apply anti-oxidant compound to copper connections
Step 5: Final Testing and Documentation
  • Perform final insulation resistance test – minimum 20 MΩ @ 500V DC
  • Conduct high-potential (hi-pot) test if required by local code
  • Test ground continuity – verify <1 Ω resistance
  • Energize cable under no-load conditions, monitor for 30 minutes
  • Gradually apply load while monitoring temperature and voltage drop
  • Document installation: cable route, test results, date, installer name
  • Create maintenance schedule and attach to equipment

8.4 Operational Precautions

⚠️ Critical Operational Requirements:

  • Never operate equipment with damaged cables: Even minor sheath cuts can lead to catastrophic failure in hazardous atmospheres
  • Daily pre-operation inspection: Visual check for damage, ground continuity test before starting equipment
  • Avoid cable run-over: Mark cable location clearly, use cable mats in traffic areas, train equipment operators
  • Prevent excessive tension: Monitor cable during equipment movement, stop if cable becomes taut or shows strain
  • Protect from contamination: Clean diesel fuel, hydraulic oil, or chemical spills immediately – some chemicals attack PCP sheath
  • Temperature monitoring: Use thermal imaging quarterly on connections and high-current sections
  • Cable repositioning: On trailing cables, periodically move cable drag point to distribute wear
  • Emergency procedures: If smoke, sparking, or burning smell detected, de-energize immediately and evacuate area

8.5 Maintenance Schedule

FrequencyInspection/TestAcceptance CriteriaRecord Requirements
DailyVisual inspection, ground continuity testNo visible damage, ground resistance <1 ΩOperator log entry
WeeklyDetailed visual inspection of full cable lengthNo cuts >10% sheath thickness, no armor damageMaintenance checklist
MonthlyInsulation resistance test (megger)Phase-to-phase and phase-to-ground >1 MΩTest certificate with values
QuarterlyThermal imaging of connections and cableNo hot spots >15°C above ambientThermal images archived
Semi-AnnuallyMechanical inspection of armor, flex testingNo broken armor wires, flexibility maintainedDetailed inspection report
AnnuallyComplete electrical testing, protection device verificationAll parameters within specificationsFormal test certificate

9. Common Problems and Troubleshooting for DM2N Cables

9.1 Typical Failure Modes in Flexible Armored Cables

ProblemSymptomsRoot CausesSolutionsPrevention
Armor Wire BreakageProtruding wires, bulges in sheath, loss of flexibilityExcessive bending stress, fatigue from cyclic loading, corrosion of galvanizingWrap with armor repair tape if <5 wires broken; replace cable if >5 wires or if armor function compromisedAdhere to 10× minimum bend radius, rotate cable position on drum, control corrosive exposure, inspect regularly
Sheath Abrasion/WearThinning of outer sheath, visible armor, white stress marksDragging on rough mine floor, inadequate cable protection, equipment run-overApply PCP repair compound for <30% wear; replace if armor exposed or >50% thickness lossInstall cable mats in traffic areas, use cable track systems, mark cable route clearly, train operators
Conductor Fatigue BreakIntermittent power loss, voltage fluctuations, complete circuit failureExcessive flexing, tight bend radius violations, torsion stressLocate break with TDR, cut out damaged section, install approved splice kit maintaining armor continuityRespect minimum bend radius (10× OD), avoid tight loops, use proper reeling techniques if applicable
Insulation Breakdown (EPR)Ground faults, protective device tripping, reduced megger readingsWater ingress through damaged sheath, mechanical crushing, thermal overload, agingMegger test to locate fault zone, assess if moisture-related (dry and retest), replace section if insulation compromisedSeal all terminations properly, avoid overloading, install strain relief, periodic megger testing, prevent water accumulation
Armor Ground Path FailureHigh ground resistance (>1 Ω), ground monitoring alarm, equipment won’t startCorroded armor connections, broken continuity bond, loose gland assemblyInspect all armor-to-ground connections, clean corrosion, re-torque gland assemblies, ensure proper bondingUse corrosion-resistant connectors, apply anti-oxidant compound, properly torque all connections, seal against moisture
Termination OverheatingHot spots on thermal imaging, discolored connections, melted insulation at glandUndersized terminals, loose connections, oxidized copper, excessive contact resistanceDe-energize, disassemble termination, clean/replace damaged components, apply proper torque, use calibrated wrenchSize terminals correctly per ampacity, use anti-oxidant compound, torque to specification, regular thermal inspection
Cable Crushing DamageFlattened cross-section, conductor deformation visible on X-ray, reduced ampacityEquipment run-over, rockfall impact, improper storage (horizontal drums)If conductors undamaged and insulation intact: monitor closely; if conductors deformed >10%: replace cable sectionInstall cable protection mats, use cable bridges at crossings, proper drum storage (vertical), adequate support spacing
Chemical Attack on PCP SheathSheath softening, swelling, discoloration, surface crackingExposure to incompatible chemicals (strong acids/bases, certain solvents), fuel/oil spillsClean contamination immediately, assess damage extent; if <20% thickness affected: wrap with protective tape; if severe: replaceClean spills promptly, maintain chemical compatibility chart, protect cables from process chemicals, use cable with appropriate sheath material
Moisture IngressDeclining insulation resistance, condensation visible at terminations, corrosion of conductors at cut endsUnsealed cable ends, damaged sheath, capillary action along stranded conductors, improper gland installationIdentify entry point, seal properly, attempt drying (low heat, dry air circulation), replace if persistent <1 MΩUse IP-rated cable glands, apply heat-shrink boots, seal all penetrations, proper drainage, inspect seals regularly

9.2 Diagnostic Procedures

🔍 Systematic Troubleshooting Approach:

Phase 1: Safety and Isolation
  1. Implement lockout/tagout (LOTO) procedures per OSHA 29 CFR 1910.147
  2. De-energize all power sources to affected cable
  3. Verify zero voltage using calibrated test equipment
  4. Discharge any residual capacitance to ground
  5. Secure work area and post warning signs
Phase 2: Visual and Physical Inspection
  1. Inspect entire cable length for physical damage
  2. Check terminations for loose connections, overheating signs, corrosion
  3. Examine armor for broken wires, especially at flex points
  4. Look for sheath damage, abrasion wear, chemical contamination
  5. Document all findings with photographs
Phase 3: Electrical Testing
  1. Continuity Test: Verify conductor continuity phase-to-phase, measure resistance
  2. Insulation Resistance Test: Megger test at 500V DC (0.6/1 kV) or 1000V DC (3.6/6 kV)
  3. Ground Path Test: Measure armor + earth conductor resistance (should be <1 Ω)
  4. Fault Location: If fault detected, use Time Domain Reflectometer (TDR) to pinpoint location
  5. Polarization Index: For moisture assessment, compare 1-minute vs 10-minute megger readings
Phase 4: Decision Matrix
Test ResultsDiagnosisAction
Insulation resistance >20 MΩ, continuity OK, ground <1 ΩCable OK – problem elsewhereCheck connections, protection devices, equipment
Insulation resistance 1-20 MΩ, declining trendMoisture ingress or insulation degradationDry cable, seal moisture entry, monitor closely
Insulation resistance <1 MΩ persistentlyInsulation failureReplace cable or damaged section
Open circuit on one or more conductorsConductor breakTDR to locate, splice or replace section
Ground resistance >1 ΩArmor or earth conductor failureInspect connections, repair bonding, replace if armor broken

9.3 Repair vs. Replacement Decision Criteria

❌ When to Replace Cable (Do NOT Repair):

  • More than 5 armor wires broken in any single location
  • Conductor strand breakage exceeding 10% of total strands
  • Insulation resistance persistently below 1 MΩ after drying attempts
  • Evidence of thermal damage (discolored or melted insulation)
  • Severe crushing with conductor deformation >10% of nominal diameter
  • Multiple splice points (>3 splices per 100 meters)
  • Sheath damage exposing armor over >30% of circumference or >1 meter length
  • Cable subjected to short-circuit current exceeding I²t rating
  • Service life exceeds 15 years with signs of aging (cracking, brittleness)
  • Chemical attack causing sheath material degradation >30% wall thickness

10. UNE 22512 vs UNE 22511: Flexible vs. Rigid Armored Cables

10.1 Key Differences Between Standards

📗 UNE 22511 – Rigid Armored Cables

Cable Type: VVMV (PVC-PVC-Metal-PVC)

Primary Use: Fixed installations, permanent distribution

Insulation: PVC (limited flexibility, lower cost)

Armor: Round galvanized steel wires (1.8-2.5mm diameter), rigid construction

Flexibility: Limited – suitable only for fixed routing

Temperature Range: -15°C to +80°C

Applications: Gallery distribution, conveyor feeds, pump stations, lighting circuits

Advantages: Lower cost, excellent mechanical protection, simpler installation for fixed routes

📕 UNE 22512 – Flexible Armored Cables

Cable Type: DM2N (EPR-Flexible Metal Cable-PCP)

Primary Use: Mobile equipment, trailing applications

Insulation: EPR (superior flexibility, heat resistance)

Armor: Galvanized steel wire cables (flexible, 0.4-0.8mm wires), maintains 80% flexibility

Flexibility: High – designed for continuous movement

Temperature Range: -20°C to +85°C (wider range)

Applications: Continuous miners, shuttle cars, LHDs, mobile drills, trailing cables

Advantages: Combines flexibility with armor protection, suitable for mobile equipment

10.2 Detailed Specification Comparison

SpecificationUNE 22511 (Rigid Armored)UNE 22512 (Flexible Armored)Impact on Selection
Conductor ClassClass 1 (≤4 mm²)
Class 2 (>6 mm²)
Class 5 (all sizes)Class 5 provides much greater flexibility for mobile applications
Insulation MaterialPVC Type BEPR Type 3GI3EPR offers better flexibility, heat resistance, and low-temp performance
Armor Wire Diameter1.8-2.5mm (single wires)0.4-0.8mm (in cable form)Smaller wires in flexible cables maintain flexibility while providing protection
Minimum Bend Radius (Fixed)12× outer diameter10× outer diameterFlexible cable can navigate tighter corners
Outer Sheath MaterialPVC Type ST2Polychloroprene (PCP)PCP provides superior oil, weather, and ozone resistance for mobile applications
Weight (50mm² 3-core + earth)~6.2 kg/m~7.5 kg/mFlexible cables slightly heavier due to more complex construction
Cost (Relative)100% (baseline)135-150%Flexible armored cables cost 35-50% more due to specialized construction
Service Life (Mobile)Not suitable5-10 years typicalOnly flexible cables appropriate for mobile equipment
Service Life (Fixed)15-20 years15-20 yearsBoth provide excellent service life in fixed installations

10.3 Application Selection Guide

📋 When to Choose UNE 22511 (Rigid Armored):

  • ✓ Fixed permanent installations with defined routing
  • ✓ Underground distribution galleries, cable tunnels
  • ✓ Conveyor system power supplies
  • ✓ Fixed pump and fan installations
  • ✓ Lighting distribution circuits
  • ✓ Budget-constrained projects where flexibility not required
  • ✓ Environments requiring maximum mechanical protection (rockfall areas)

📋 When to Choose UNE 22512 (Flexible Armored):

  • ✓ All mobile mining equipment (continuous miners, shuttle cars, LHDs)
  • ✓ Trailing cable applications where cable follows equipment
  • ✓ Mobile drills and roof bolters
  • ✓ Temporary installations requiring frequent relocation
  • ✓ Equipment with complex movement patterns
  • ✓ Applications requiring both flexibility AND armor protection
  • ✓ Environments with oil/fuel exposure (quarries, diesel equipment areas)

11. Comprehensive Technical Specifications Data

11.1 Standard DM2N Cable Construction Data

Cable DesignationVoltage RatingConductor SizeNo. of CoresConductor ClassOuter Diameter (approx.)Weight (approx.)Copper Content
DM2N 0.6/1 kV (3×16+3×8) F0.6/1 kV16 mm² power / 8 mm² earth6IEC 60228 Class 532-35 mm3.2 kg/m72 kg/km
DM2N 0.6/1 kV (3×25+3×10) F0.6/1 kV25 mm² power / 10 mm² earth6IEC 60228 Class 538-42 mm4.2 kg/m105 kg/km
DM2N 0.6/1 kV (3×35+3×16) F0.6/1 kV35 mm² power / 16 mm² earth6IEC 60228 Class 542-46 mm5.5 kg/m153 kg/km
DM2N 0.6/1 kV (3×50+3×25) F0.6/1 kV50 mm² power / 25 mm² earth6IEC 60228 Class 548-52 mm7.5 kg/m225 kg/km
DM2N 0.6/1 kV (3×70+3×35) F0.6/1 kV70 mm² power / 35 mm² earth6IEC 60228 Class 555-60 mm10.2 kg/m315 kg/km
DM2N 0.6/1 kV (3×95+3×50) F0.6/1 kV95 mm² power / 50 mm² earth6IEC 60228 Class 562-68 mm13.8 kg/m435 kg/km
DM2N 0.6/1 kV (3×120+3×70) F0.6/1 kV120 mm² power / 70 mm² earth6IEC 60228 Class 570-76 mm17.5 kg/m570 kg/km
DM2N 0.6/1 kV (3×150+3×70) F0.6/1 kV150 mm² power / 70 mm² earth6IEC 60228 Class 575-82 mm19.5 kg/m660 kg/km
DM2N 3.6/6 kV (3×35) F3.6/6 kV35 mm² with screens3IEC 60228 Class 552-56 mm6.8 kg/m105 kg/km
DM2N 3.6/6 kV (3×50) F3.6/6 kV50 mm² with screens3IEC 60228 Class 558-62 mm8.2 kg/m150 kg/km
DM2N 3.6/6 kV (3×70) F3.6/6 kV70 mm² with screens3IEC 60228 Class 565-70 mm11.5 kg/m210 kg/km
DM2N 3.6/6 kV (3×95) F3.6/6 kV95 mm² with screens3IEC 60228 Class 572-78 mm15.5 kg/m285 kg/km

Note: Dimensions and weights are approximate and may vary by manufacturer. Always verify specifications with specific product datasheets.

12. References and Authoritative Citations

12.1 Primary Standard References

  • UNE 22512:1996 – Electric Cables for Underground Mining. Flexible Armored Cables. EPR Insulated. Nominal Voltage 0,6/1 kV to 3,6/6 kV. Type DM2N. Spanish Association for Standardization and Certification (AENOR), 1996.
  • European Standards Reference – UNE 22512:1996 Classification and International Equivalents. European Standards Database.
  • Sumcab Mine DM2N Technical Data – Flexible armored cable specifications per UNE 22512. Sumcab Specialcable Group S.L., Spain.

12.2 Related Mining Cable Standards

  • UNE 22510:1996 – Electric Cables for Underground Mining. General Requirements.
  • UNE 22511:1996 – Electric Cables for Underground Mining. Rigid Armored Cables.
  • UNE 22513:1996 – Electric Cables for Underground Mining. Flexible Non-Armored Cables.
  • IEC 60228 – Conductors of insulated cables. International Electrotechnical Commission.
  • IEC 60502-1 – Power cables with extruded insulation and their accessories for rated voltages from 1 kV up to 30 kV – Part 1.
  • DIN VDE 0250-813 – Cables, wires and flexible cords for power installation: Flexible cables for mining purposes.
  • DIN VDE 0207-20 – Insulating materials and sheaths for cables and flexible cords – Part 20: Elastomeric insulating compounds.
  • DIN VDE 0207-21 – Insulating materials and sheaths for cables and flexible cords – Part 21: Elastomeric sheathing compounds.

12.3 Industry Technical Resources

  • Reeling Cable Solutions – Comprehensive technical information on flexible power cables for mobile machinery, reeling applications, and cable management in mining environments. Feichun Cable reeling cable division.
  • Amplex Mining Cables Australia – AS/NZS compliant mining cable specifications for Australian mining operations, including flexible trailing cables and armored power cables equivalent to UNE 22512 standards.
  • Underground Mining Cable Selection Guide – Technical guide covering IEC 60502-1, AS/NZS 2802, and mining cable specifications. Henan Province Jianyun Cable Co., Ltd.
  • Type 409 Flexible Mining Cables – EPR insulated flexible trailing cable specifications per AS/NZS standards. Eland Cables International.
  • Mining Cables Technical Blog – Engineering specifications for trailing cables, reeling cables, and flexible armored cables for underground mining. Feichun Special Cable technical resources.
  • Tele-Fonika Mining Cables Catalogue – Comprehensive product specifications for EPR insulated flexible mining cables including DM2N equivalent types.

12.4 Quality and Safety Standards

  • ISO 9001:2015 – Quality management systems – Requirements for consistent cable manufacturing.
  • ISO 14001:2015 – Environmental management systems – Sustainable production practices.
  • EN 60332-1-2 / IEC 60332-1-2 – Tests on electric cables under fire conditions – Single cable vertical flame test.
  • EN 60332-3-24 / IEC 60332-3-24 – Tests on electric cables under fire conditions – Vertical flame spread Category C.
  • EN 61034-2 / IEC 61034-2 – Measurement of smoke density of cables burning under defined conditions.
  • EN 60754-2 / IEC 60754-2 – Test on gases evolved during combustion – pH and conductivity measurement.
  • RoHS II Directive 2011/65/EU – Restriction of Hazardous Substances in electrical equipment.
  • ICEA S-75-381 – Portable and Power Feeder Cables for Use in Mines (North American reference).
  • AS/NZS 1802:2003 – Electric cables – Reeling cables for underground mining.
  • AS/NZS 2802:2000 – Electric cables – Mining and industrial trailing cables.

📚 Request Additional Technical Documentation:

Anhui Feichun Special Cable Co., Ltd. maintains extensive technical libraries including:

  • Complete UNE 22512 standard interpretation documents
  • DM2N cable selection guides and ampacity calculation tools
  • Installation procedure manuals with step-by-step instructions
  • Maintenance and troubleshooting handbooks
  • Chemical compatibility charts for PCP and EPR materials
  • Test certificates and quality assurance documentation
  • CAD drawings and 3D models for custom cable designs
  • Training materials for cable installation and maintenance personnel

Contact our technical support team:

📧 [email protected] | 📧 [email protected] | 📱 WhatsApp: +86 13855 123218

Conclusion

UNE 22512:1996 represents a specialized and sophisticated standard for flexible armored mining cables that addresses a critical challenge in underground mining: providing electrical power to mobile equipment that requires both armor-level mechanical protection and cable flexibility for continuous movement. The Type DM2N designation encompasses a family of cables featuring EPR insulation for superior flexibility and temperature performance, combined with innovative flexible steel wire cable armor that maintains 80-85% of non-armored cable flexibility while delivering robust mechanical protection.

This standard, harmonized with international requirements including IEC, DIN VDE, AS/NZS, and ICEA standards, ensures that UNE 22512 cables meet the extreme demands of modern mining operations worldwide. From continuous miners and shuttle cars to LHD vehicles and mobile drills, DM2N cables provide the reliability, durability, and safety required for equipment operating in some of the world’s most challenging industrial environments.

Anhui Feichun Special Cable Co., Ltd. specializes in manufacturing UNE 22512 compliant Type DM2N cables with proven performance in demanding underground mining applications. Our commitment to quality, backed by ISO 9001:2015 certification, state-of-the-art manufacturing facilities, and comprehensive testing protocols, ensures reliable power transmission for your mobile mining equipment. Whether you need standard configurations or custom-designed cables for specific applications, our experienced engineering team can provide optimal solutions.

🔌 Partner with Feichun Cable for Your UNE 22512 Cable Requirements

From technical consultation and custom design to manufacturing and global logistics, we provide comprehensive solutions for your mining cable needs.

📧 Technical Engineering:
[email protected]
📧 Sales & Custom Solutions:
[email protected]
📱 Instant Response:
WhatsApp: +86 13855 123218

Anhui Feichun Special Cable Co., Ltd. (安徽飞纯特种电缆有限公司)
Professional Manufacturer of UNE 22512 Type DM2N Flexible Armored Mining Cables
EPR Insulated | Flexible Armor | 0.6/1 kV to 3.6/6 kV | Mobile Equipment Specialists
ISO 9001:2015 Certified | RoHS Compliant | CE Marked | Global Mining Solutions Provider

© 2025 Anhui Feichun Special Cable Co., Ltd. All Rights Reserved.
This technical document is provided for informational and educational purposes. While every effort has been made
to ensure accuracy and completeness, always consult applicable standards and regulations for your specific application.

Article last updated: November 2025 | UNE 22512:1996 Type DM2N Flexible Armored Mining Cables Technical Reference

💬 WhatsApp: +86 13855 123218
Previous Article

What is UNE 22510:1996 Mining Cables?

Next Article

What is CEI 20-27 CENELEC HD361 Cable?

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注