ÖLFLEX® EB — кабель управления для искробезопасных цепей type of protection “i”

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
ÖLFLEX® EB — кабель управления для искробезопасных цепей type of protection i
ÖLFLEX® EBIntrinsic SafetyType iOutdoorRAL 5015IEC 60079-14

ÖLFLEX® EB — кабель управления для искробезопасных цепей type of protection “i”

Control cable for intrinsically safe circuits according to IEC 60079-14 / EN 60079-14 / VDE 0165-1, with sky blue PVC outer sheath similar to RAL 5015 and UV/weather resistance.

ÖLFLEX® EB is a control cable for intrinsically safe circuits, type of protection “i”. The sky blue outer sheath similar to RAL 5015 gives clear visual identification for intrinsic safety circuits and supports correct separation from ordinary control wiring.

The cable is based on EN 50525-2-51, uses fine-wire bare copper conductors, PVC insulation LAPP P8/1, black numbered cores according to VDE 0293-334 and a PVC outer sheath in sky blue. It is UV and weather-resistant according to ISO 4892-2 and suitable for outdoor applications.

✓ Intrinsically safe circuits✓ Type of protection i✓ IEC 60079-14✓ EN 60079-14✓ VDE 0165-1✓ Sky blue RAL 5015✓ U0/U 300/500 V✓ Outdoor UV/weather-resistant
Product family
ÖLFLEX EB
intrinsically safe circuit cable
Protection concept
Type “i”
intrinsic safety circuits
Outer sheath
Sky blue
similar RAL 5015
Capacitance
140 nF/km
core/core approx.
Inductivity
0.52 mH/km
approx.
Bending radius
15×D / 4×D
occasional flexing / fixed installation

1. Product positioning: sky-blue control cable for intrinsic safety

ÖLFLEX EB should be positioned as a specialized control cable for intrinsically safe circuits. Its strongest identifying feature is the sky blue PVC outer sheath similar to RAL 5015, which supports clear visual assignment of circuits used in type of protection “i” areas.

Recommended catalog description: ÖLFLEX EB is a control cable for intrinsically safe circuits according to IEC 60079-14 / EN 60079-14 / VDE 0165-1. It has fine-wire bare copper conductors, PVC insulation LAPP P8/1, black numbered cores, layered core twisting and a sky blue PVC outer sheath similar to RAL 5015. The cable is UV/weather-resistant according to ISO 4892-2 and suitable for outdoor applications.

2. CAD-style engineering section drawing

CAD-style section A-A · ÖLFLEX EB · vertical engineering drawing · sky blue sheath for intrinsically safe circuits
101 202 303 404 PEGN Ø 5.4–16.9 mm 6 5 4 3 2 1 FEICHUN CABLES — SECTION A-A · VERTICAL LAYOUT ÖLFLEX EB · INTRINSICALLY SAFE CIRCUITS CONTROL CABLE Sky blue RAL 5015 · type of protection i · IEC 60079-14 DWG FC-OLF-EB-01V · Rev 01 C approx. 140 nF/km · L approx. 0.52 mH/km Scale NTS Class 5 copper · 300/500 V

This vertical engineering illustration shows the EB construction: black numbered PVC-insulated cores, layered twisting and sky blue PVC outer sheath for visual identification of intrinsically safe circuits. G versions include a GN-YE protective conductor; X versions are supplied without protective conductor.

Pos.ElementMaterial / specification
1Sky blue outer sheathPVC outer sheath, sky blue, similar to RAL 5015; UV/weather-resistant according to ISO 4892-2
2Visual intrinsic-safety identitySky blue cable color supports clear assignment to intrinsically safe circuits, type of protection “i”
3Layered core lay-upCores twisted in layers for flexible control-cable geometry
4Black numbered coresPVC insulation LAPP P8/1; black with white numbers according to VDE 0293-334
5Optional protective conductorG versions include GN-YE protective conductor; X versions are without GN-YE
6Fine-wire conductorBare copper wires, class 5 according to VDE 0295 / IEC 60228
Representative range from the provided EB data: 0.75–1.5 mm² · 2 to 25 cores in the listed selection · outer diameter 5.4–16.9 mm · copper index 14.7–360 kg/km · weight 50–698 kg/km.
Engineering meaning of EB: the product is intended for intrinsically safe circuits according to IEC 60079-14 / EN 60079-14 / VDE 0165-1. The sky blue sheath is the key visual marker for type of protection “i” wiring.
Sky blue PVC outer sheath, similar RAL 5015
Black numbered PVC-insulated cores
Optional GN-YE protective conductor
Bare copper fine-wire conductors

3. Product make-up

1. Fine-wire copper conductor
Fine-wire strand made of bare copper wires according to VDE 0295, class 5 / IEC 60228 class 5.
2. PVC insulation LAPP P8/1
The cores are insulated with PVC LAPP P8/1 and identified as black cores with white numbers according to VDE 0293-334.
3. Cores twisted in layers
Layered core twisting supports a stable, flexible and space-saving control-cable structure.
4. Sky blue PVC outer sheath
The outer sheath is sky blue similar to RAL 5015 and provides clear identification for intrinsically safe circuits.
5. Outdoor suitability
The sheath is UV and weather-resistant according to ISO 4892-2, supporting outdoor applications.

4. Technical data

ParameterValue
Product typeControl cable for intrinsically safe circuits
Application standardIEC 60079-14:2013 / EN 60079-14:2014 / VDE 0165-1:2014, section 16.2.2
Type of protection“i” intrinsic safety
ETIM 5.0/6.0Class-ID: EC000104; Class-Description: Control cable
Norm referenceBased on EN 50525-2-51
Core identificationBlack with white numbers according to VDE 0293-334
Mutual capacitanceCore/core approx. 140 nF/km
InductivityApprox. 0.52 mH/km
ConductorFine-wire strand made of bare copper wires
Conductor strandingFine wire according to VDE 0295, class 5 / IEC 60228 class 5
Core insulationPVC insulation LAPP P8/1
Core lay-upCores twisted in layers
Outer sheathPVC, sky blue, similar to RAL 5015
Outdoor resistanceUV and weather-resistant according to ISO 4892-2
Nominal voltageU0/U 300/500 V
Test voltageCore/core: 3000 V
Minimum bending radiusOccasional flexing: 15 x outer diameter; fixed installation: 4 x outer diameter
Temperature rangeOccasional flexing: -5 °C to +70 °C; fixed installation: -40 °C to +80 °C
Flame-retardantAccording to IEC 60332-1-2
Protective conductorX = without protective conductor; G = with GN-YE protective conductor

5. Application range

Intrinsically safe circuits

Main application: intrinsically safe circuits with type of protection “i” according to IEC 60079-14 / EN 60079-14 / VDE 0165-1.

Outdoor installations

The cable is suitable for outdoor applications because the sky blue sheath is UV and weather-resistant according to ISO 4892-2.

Process automation

Useful for control and signal circuits in process areas where intrinsic safety identification is required.

Plant engineering

Suitable for plant wiring where space-saving control cables and clear circuit identification are required.

Measurement circuits

The listed mutual capacitance and inductivity values support technical assessment for control and measurement wiring.

Sky-blue circuit separation

The RAL 5015-like outer sheath helps separate intrinsic safety circuits from standard wiring in cable routes.

6. Product range from the provided data

Article numberNumber of cores and mm² per conductorOuter diameter [mm]Copper index [kg/km]Weight [kg/km]Version
00124202 X 0.755.414.750Without GN/YE
00124213 X 0.755.722.160Without GN/YE
00124304 X 0.756.229.481Without GN/YE
00124225 X 0.756.736.888Without GN/YE
00124237 X 0.757.351.5115Without GN/YE
001242512 X 0.759.988.2185Without GN/YE
001242718 X 0.7511.7132.3282Without GN/YE
001242925 X 0.7513.8183.8393Without GN/YE
00124402 X 1.05.719.757Without GN/YE
00124413 X 1.06.029.673Without GN/YE
00124435 X 1.07.149.4105Without GN/YE
00124447 X 1.08.069.1138Without GN/YE
001244612 X 1.010.5118.4231Without GN/YE
001244818 X 1.012.7177.7331Without GN/YE
00124012 X 1.56.32980Without GN/YE
00124023 X 1.56.743105Without GN/YE
00124034 X 1.57.258125Without GN/YE
00124045 X 1.58.172139Without GN/YE
00125013 G 1.56.743105With GN/YE
00125024 G 1.57.258125With GN/YE
00125035 G 1.58.172139With GN/YE
00125047 G 1.58.9101180With GN/YE
001250512 G 1.512.0173339With GN/YE
001250618 G 1.514.4259513With GN/YE
001250725 G 1.516.9360698With GN/YE

Unless specified otherwise, the shown product values are nominal values. Detailed values, such as tolerances, are available upon request. Copper price basis: EUR 150/100 kg. Standard packaging size is coil ≤ 30 kg or ≤ 250 m, otherwise drum. The preferred type of packaging can be specified, for example 1 × 500 m drum or 5 × 100 m coils.

7. Selection guide

Selection criterionRecommended checkEngineering meaning
Intrinsic safety requirementConfirm whether the circuit is an intrinsically safe type “i” circuitÖLFLEX EB is intended for intrinsically safe circuits according to IEC 60079-14 / EN 60079-14 / VDE 0165-1.
Color identificationCheck whether sky blue circuit identification is requiredThe sky blue sheath similar to RAL 5015 helps identify EB circuits during installation and maintenance.
Outdoor exposureCheck whether the cable route is exposed to sunlight or weatherThe cable is UV and weather-resistant according to ISO 4892-2.
Protective conductorChoose X or G versionX is without protective conductor; G includes GN-YE protective conductor.
Electrical parametersReview capacitance and inductivity for circuit assessmentThe data lists mutual capacitance approx. 140 nF/km and inductivity approx. 0.52 mH/km.
Bending conditionUse 15 x D for occasional flexing and 4 x D for fixed installationCorrect bending radius protects the conductor and sheath geometry.

8. Detailed feature interpretation

FeatureTechnical functionPractical benefitCatalog wording
Sky blue sheathProvides visual identification for intrinsic safety wiringEasier separation from ordinary control cablesOuter sheath: PVC, sky blue similar to RAL 5015
Type “i” applicationDefines the intended use in intrinsically safe circuitsSupports correct product selection for intrinsic safety areasFor use within intrinsically safe circuits – type of protection “i”
UV/weather resistanceProtects the cable sheath outdoorsSuitable for outdoor applicationsUV and weather-resistant according to ISO 4892-2
Mutual capacitanceElectrical cable parameter for circuit assessmentUseful for intrinsic safety design reviewCore/core approx. 140 nF/km
InductivityElectrical cable parameter for loop assessmentUseful for intrinsic safety design reviewApprox. 0.52 mH/km
Numbered coresSupports circuit assignment and troubleshootingFaster installation and clearer maintenanceBlack with white numbers according to VDE 0293-334

9. SEO keyword matrix

Recommended Russian keyword clusters: ÖLFLEX EB, кабель для искробезопасных цепей, искробезопасный кабель управления, control cable for intrinsically safe circuits, intrinsically safe circuits cable, type of protection i cable, IEC 60079-14 cable, EN 60079-14 cable, VDE 0165-1 cable, sky blue control cable, кабель с голубой оболочкой, RAL 5015 cable, UV resistant control cable, outdoor intrinsically safe cable, кабель управления 300/500 В, кабель для intrinsically safe circuits.

10. FAQ

What is ÖLFLEX EB used for?

It is used for intrinsically safe circuits, type of protection “i”, according to IEC 60079-14 / EN 60079-14 / VDE 0165-1.

Why is the sheath sky blue?

The sky blue sheath similar to RAL 5015 provides clear visual identification for intrinsically safe circuits.

Is ÖLFLEX EB suitable for outdoor use?

Yes. It is suitable for outdoor applications and is UV and weather-resistant according to ISO 4892-2.

What are the key electrical parameters?

Mutual capacitance is core/core approx. 140 nF/km and inductivity is approx. 0.52 mH/km.

What is the test voltage?

The test voltage is core/core 3000 V.

What is the difference between X and G versions?

X versions are without protective conductor. G versions include a GN-YE protective conductor.

11. Ready-to-publish technical description

ÖLFLEX® EB is a control cable for intrinsically safe circuits, type of protection “i”, according to IEC 60079-14 / EN 60079-14 / VDE 0165-1. The cable has a sky blue PVC outer sheath similar to RAL 5015 for clear identification of intrinsic safety circuits. It is based on EN 50525-2-51 and constructed with fine-wire bare copper conductors according to VDE 0295 / IEC 60228 class 5, PVC insulation LAPP P8/1, black cores with white numbers according to VDE 0293-334 and layered core twisting. ÖLFLEX EB is UV and weather-resistant according to ISO 4892-2, flame-retardant according to IEC 60332-1-2 and suitable for outdoor applications. Technical values include U0/U 300/500 V nominal voltage, core/core 3000 V test voltage, mutual capacitance of approx. 140 nF/km and inductivity of approx. 0.52 mH/km.

ÖLFLEX® EB · Control cable for intrinsically safe circuits · Type of protection “i” · Sky blue RAL 5015

Professional Russian SEO product page for a control cable for intrinsically safe circuits with sky blue PVC outer sheath, UV/weather resistance, EN 50525-2-51 based construction and electrical values for circuit assessment.

Feichun Cables · Feichun Cable

Tel: +86 13855123218 · Email: [email protected]

Document ID: FEICHUN-OLFLEX-EB-SEO-RU-VERTICAL · intrinsically safe circuits · type i · sky blue RAL 5015
Previous Article

ÖLFLEX® CLASSIC 115 CY BK — тонкий экранированный ПВХ кабель управления с черной UV-resistant наружной оболочкой

Next Article

ÖLFLEX® EB CY — экранированный кабель управления для искробезопасных цепей type of protection “i”

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注