ÖLFLEX® 140 H05VV5-F — harmonised маслостойкий ПВХ кабель управления EN 50525-2-51

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
ÖLFLEX® 140 H05VV5-F — harmonised маслостойкий ПВХ кабель управления EN 50525-2-51
ÖLFLEX® 140H05VV5-FHAROil-resistant TM5EN 50525-2-51RAL 7001

ÖLFLEX® 140 H05VV5-F — harmonised маслостойкий ПВХ кабель управления EN 50525-2-51

Certified PVC-sheathed control cable with high oil-resistance, grey outer sheath, black numbered cores and strong European acceptance due to HAR harmonisation.

ÖLFLEX® 140 H05VV5-F is a harmonised oil-resistant PVC control cable according to EN 50525-2-51. The HAR designation H05VV5-F makes the product especially relevant for European machinery, plant engineering and machine-tool wiring where harmonised acceptance matters.

The cable is mainly used in dry, damp and wet interiors, including water-oil mixtures, but it is not intended for outdoor use. Its high oil-resistance PVC outer sheath is grey, similar to RAL 7001, and oil-resistant according to EN 50363-4-1: TM5.

✓ Harmonised HAR H05VV5-F✓ EN 50525-2-51✓ Oil-resistant TM5✓ Grey high oil-resistance sheath✓ U0/U 300/500 V✓ Test voltage 2000 V✓ Machine tools✓ Indoor wet areas
Product family
ÖLFLEX 140
H05VV5-F harmonised control cable
European acceptance
HAR
harmonised designation
Oil resistance
TM5
EN 50363-4-1
Outer sheath
Grey RAL 7001
high oil-resistance PVC
Nominal voltage
300/500 V
control cable class
Bending radius
12.5×D / 4×D
occasional flexing / fixed installation

1. Product positioning: harmonised oil-resistant indoor control cable

ÖLFLEX 140 H05VV5-F should be positioned as a certified, harmonised and oil-resistant control cable for European machine and plant applications. It is especially relevant where the buyer needs a cable with the H05VV5-F designation and oil-resistant PVC sheath for dry, damp or wet interiors.

Recommended catalog description: ÖLFLEX 140 H05VV5-F is a harmonised PVC control cable according to EN 50525-2-51 with black numbered cores, fine-wire copper conductors and a grey high oil-resistance PVC outer sheath similar to RAL 7001. It is oil-resistant according to EN 50363-4-1: TM5 and suitable for plant engineering, industrial machinery, heating and air-conditioning systems and machine tools in indoor environments.

Important application note: The product is mainly used in dry, damp and wet interiors, including water-oil mixtures, but not for outdoor use. This distinction should be kept clear in product pages and selection guides.

2. CAD-style engineering section drawing

CAD-style section A-A · ÖLFLEX 140 H05VV5-F · vertical engineering drawing · oil-resistant grey PVC control cable
101 202 303 404 PEGN Ø 5.5–29.6 mm 6 5 4 3 2 1 FEICHUN CABLES — SECTION A-A · VERTICAL LAYOUT ÖLFLEX 140 H05VV5-F · OIL-RESISTANT HAR CONTROL CABLE Grey high oil-resistance PVC sheath · EN 50525-2-51 · TM5 DWG FC-OLF-140-H05VV5F-01V · Rev 01 Indoor dry/damp/wet interiors · not for outdoor use Scale NTS Class 5 copper · 300/500 V

This vertical engineering illustration shows the ÖLFLEX 140 H05VV5-F construction: fine-wire copper conductors, black numbered PVC-insulated cores, layered twisting and grey high oil-resistance PVC outer sheath for machine and plant wiring.

Pos.ElementMaterial / specification
1Grey high oil-resistance sheathPVC outer sheath, high oil-resistance, grey, similar to RAL 7001
2TM5 oil-resistant layer logicOil-resistant according to EN 50363-4-1: TM5 for water-oil mixtures and machine-tool interiors
3Layered core lay-upCores twisted in layers for flexible control-cable geometry
4Black numbered coresPVC core insulation; black with white numbers according to VDE 0293-334
5Protective conductorG versions include GN-YE protective conductor
6Fine-wire conductorBare copper wires, class 5 according to VDE 0295 / IEC 60228
Representative range from the provided ÖLFLEX 140 data: 0.5–2.5 mm² · 3 to 41 cores in the listed selection · outer diameter range 5.5–29.6 mm · copper index 14.4–600 kg/km · weight 62.4–1109.6 kg/km.
Engineering meaning of H05VV5-F: this harmonised designation supports high European acceptance. The product is intended for indoor machine and plant wiring where oil resistance is required, not for outdoor use.
Grey high oil-resistance PVC outer sheath
Oil-resistant TM5 application layer
Black numbered PVC-insulated cores
Bare copper fine-wire conductors

3. Product make-up

1. Fine-wire copper conductor
Fine-wire strand made of bare copper wires according to VDE 0295, class 5 / IEC 60228 class 5.
2. PVC core insulation
Black cores with white numbers according to VDE 0293-334 support clear control-circuit identification.
3. Cores twisted in layers
Layered core twisting supports a stable, flexible and space-saving control-cable structure.
4. Grey high oil-resistance PVC sheath
The outer sheath is grey, similar to RAL 7001, and designed for high oil resistance according to TM5 requirements.
5. Harmonised HAR identity
The H05VV5-F designation gives the cable high acceptance in Europe and supports standardised product selection.

4. Technical data

ParameterValue
Product typeHarmonised oil-resistant PVC control cable
Harmonised designationH05VV5-F
ETIM 5.0/6.0Class-ID: EC000104; Class-Description: Control cable
Norm referenceEN 50525-2-51
Oil resistanceAccording to EN 50363-4-1: TM5
Core identificationBlack with white numbers according to VDE 0293-334
ConductorFine-wire strand made of bare copper wires
Conductor strandingFine wire according to VDE 0295, class 5 / IEC 60228 class 5
Core insulationPVC core insulation
Core lay-upCores twisted in layers
Outer sheathPVC outer sheath, high oil-resistance, grey, similar to RAL 7001
Nominal voltageU0/U 300/500 V
Test voltage2000 V
Minimum bending radiusOccasional flexing: 12.5 x outer diameter; fixed installation: 4 x outer diameter
Temperature rangeOccasional flexing: -5 °C to +70 °C; fixed installation: -40 °C to +70 °C
Flame-retardantAccording to IEC 60332-1-2
Protective conductorG = with GN-YE protective conductor; X = without protective conductor
Product noteTrade product, no Lapp product

5. Application range

Plant engineering

Suitable for plant wiring where harmonised European acceptance and oil resistance are required.

Industrial machinery

Designed for control circuits in industrial machinery with medium mechanical load conditions.

Machine tools

A strong use case due to oil resistance and suitability for water-oil mixtures in indoor machine environments.

HVAC systems

Applicable in heating and air-conditioning systems when an oil-resistant harmonised control cable is required.

Dry, damp and wet interiors

Mainly used in dry, damp and wet interiors, including water-oil mixtures.

Not for outdoor use

The application data explicitly excludes outdoor use, so outdoor routing should be avoided.

6. Product range from the provided data

Article numberNumber of cores and mm² per conductorOuter diameter [mm]Copper index [kg/km]Weight [kg/km]
00110003 G 0.55.5 – 7.014.462.4
00111044 G 0.56.2 – 7.919.268.2
00110015 G 0.56.8 – 8.62487.1
00110027 G 0.58.3 – 10.433.6118.7
001100312 G 0.510.4 – 12.958198
001100418 G 0.512.3 – 15.386.4266.9
001100525 G 0.514.8 – 18.3120380.4
001100634 G 0.517.2 – 21.2163.2509
00110093 G 0.756.0 – 7.621.675.6
00112044 G 0.756.6 – 8.328.883.9
00110105 G 0.757.4 – 9.336113.3
00110117 G 0.759.0 – 11.350145
001101212 G 0.7511.0 – 13.786244.9
001101318 G 0.7513.2 – 16.4130327.7
001101425 G 0.7515.8 – 19.5180466.4
001101534 G 0.7518.4 – 22.6245626.5
001124141 G 0.7520.1 – 24.7296748
00110183 G 1.06.3 – 8.028.889.3
00113044 G 1.06.9 – 8.738.498.6
00110195 G 1.07.8 – 9.848132.1
00110207 G 1.09.5 – 11.867169.3
001102112 G 1.011.8 – 14.6115285.9
001102218 G 1.014.0 – 17.2173405.2
001102325 G 1.016.8 – 20.7240569.5
001102434 G 1.019.6 – 24.0326741.7
001134141 G 1.021.4 – 26.2394886
00110273 G 1.57.4 – 9.443109.8
00114044 G 1.58.2 – 10.258140.7
00110285 G 1.59.1 – 11.472175
00110297 G 1.511.3 – 14.1101224.2
001103012 G 1.513.8 – 17.0173361.7
001103118 G 1.516.5 – 20.3259518.3
001103225 G 1.519.8 – 24.3360729.9
001103334 G 1.523.1 – 28.2490946.6
00110363 G 2.59.0 – 11.272162.4
00115044 G 2.510.1 – 12.596203.3
00110375 G 2.511.0 – 13.7120251.1
00110387 G 2.513.6 – 16.8168326
001103912 G 2.516.8 – 20.6288553.3
001104514 G 2.518.3 – 22.7336611
001104018 G 2.520.2 – 24.8432795.2
001104125 G 2.524.2 – 29.66001109.6

Unless specified otherwise, the shown product values are nominal values. Detailed values, such as tolerances, are available upon request. Copper price basis: EUR 150/100 kg. Standard packaging size is coil ≤ 30 kg or ≤ 250 m, otherwise drum. The preferred type of packaging can be specified, for example 1 × 500 m drum or 5 × 100 m coils.

7. Selection guide

Selection criterionRecommended checkEngineering meaning
Harmonised requirementCheck whether H05VV5-F or HAR acceptance is requiredÖLFLEX 140 offers high acceptance in Europe due to harmonisation.
Oil exposureCheck whether the cable route includes oil or water-oil mixturesThe cable is oil-resistant according to EN 50363-4-1: TM5.
Installation environmentUse in dry, damp and wet interiors onlyThe catalog application explicitly states not for outdoor use.
Movement conditionUse only fixed installation or occasional free movement without tensile loadNot intended for continuous compulsory-guided motion.
Protective conductorMost listed versions are G versions with GN-YE protective conductorConfirm the required conductor arrangement before ordering.
Bending conditionUse 12.5 x D for occasional flexing and 4 x D for fixed installationCorrect bending radius protects conductor and sheath geometry.

8. Detailed feature interpretation

FeatureTechnical functionPractical benefitCatalog wording
H05VV5-F harmonisationDefines harmonised cable identityHigh acceptance in EuropeHarmonised HAR: H05VV5-F
TM5 oil resistanceDefines oil-resistant PVC compound behaviorSuitable for machine-tool interiors and water-oil mixturesOil-resistant according to EN 50363-4-1: TM5
Grey high oil-resistance sheathProtects the laid-up core packageGood visual identity for indoor machinery wiringPVC outer sheath, high oil-resistance, grey similar to RAL 7001
Indoor wet area suitabilitySupports use in dry, damp and wet interiorsUseful in plant and machine environments with fluidsMainly used in dry, damp and wet interiors
Numbered coresSupports circuit assignment and troubleshootingFaster installation and clearer maintenanceBlack with white numbers according to VDE 0293-334
Class 5 conductorProvides flexible conductor structureSuitable for fixed installation and occasional flexingFine wire according to VDE 0295 / IEC 60228 class 5

9. SEO keyword matrix

Recommended Russian keyword clusters: ÖLFLEX 140, H05VV5-F, harmonised control cable, HAR control cable, маслостойкий кабель управления, кабель управления H05VV5-F, oil resistant PVC control cable, EN 50525-2-51 cable, EN 50363-4-1 TM5 cable, grey PVC control cable, кабель для станков, кабель для машиностроения, cable for machine tools, dry damp wet interiors cable, control cable 300/500 V, PVC sheath certified cable.

10. FAQ

What does H05VV5-F mean for this cable?

H05VV5-F is the harmonised designation. It supports high acceptance in Europe and identifies the cable as a harmonised oil-resistant PVC control cable.

Is ÖLFLEX 140 oil-resistant?

Yes. The cable is oil-resistant according to EN 50363-4-1: TM5.

Can ÖLFLEX 140 be used outdoors?

No. The application data states that it is mainly used in dry, damp and wet interiors, including water-oil mixtures, but not for outdoor use.

What is the outer sheath color?

The outer sheath is grey high oil-resistance PVC, similar to RAL 7001.

What is the test voltage?

The test voltage is 2000 V.

What bending radius should be used?

For occasional flexing, use 12.5 x outer diameter. For fixed installation, use 4 x outer diameter.

11. Ready-to-publish technical description

ÖLFLEX® 140 H05VV5-F is a harmonised oil-resistant PVC control cable according to EN 50525-2-51. The cable offers high acceptance in Europe due to HAR harmonisation and is mainly used in plant engineering, industrial machinery, heating and air-conditioning systems and machine tools. It is suitable for dry, damp and wet interiors, including water-oil mixtures, but not for outdoor use. The construction includes fine-wire bare copper conductors according to VDE 0295 / IEC 60228 class 5, PVC core insulation, black cores with white numbers according to VDE 0293-334, cores twisted in layers and a grey high oil-resistance PVC outer sheath similar to RAL 7001. The cable is oil-resistant according to EN 50363-4-1: TM5, flame-retardant according to IEC 60332-1-2, has U0/U 300/500 V nominal voltage, 2000 V test voltage and a temperature range of -5 °C to +70 °C for occasional flexing and -40 °C to +70 °C for fixed installation.

ÖLFLEX® 140 H05VV5-F · Harmonised oil-resistant PVC control cable · HAR · TM5

Professional Russian SEO product page for a harmonised oil-resistant PVC control cable with grey high oil-resistance sheath, black numbered cores, HAR acceptance, EN 50525-2-51 reference and TM5 oil resistance.

Feichun Cables · Feichun Cable

Tel: +86 13855123218 · Email: [email protected]

Document ID: FEICHUN-OLFLEX-140-H05VV5-F-SEO-RU-VERTICAL · harmonised oil-resistant control cable · HAR · TM5
Previous Article

ÖLFLEX® EB CY — экранированный кабель управления для искробезопасных цепей type of protection “i”

Next Article

ÖLFLEX® 140 CY H05VVC4V5-K — harmonised экранированный маслостойкий ПВХ кабель управления

Write a Comment