ÖLFLEX® 140 H05VV5-F — harmonised маслостойкий ПВХ кабель управления EN 50525-2-51
ÖLFLEX® 140 H05VV5-F is a harmonised oil-resistant PVC control cable according to EN 50525-2-51. The HAR designation H05VV5-F makes the product especially relevant for European machinery, plant engineering and machine-tool wiring where harmonised acceptance matters.
The cable is mainly used in dry, damp and wet interiors, including water-oil mixtures, but it is not intended for outdoor use. Its high oil-resistance PVC outer sheath is grey, similar to RAL 7001, and oil-resistant according to EN 50363-4-1: TM5.
1. Product positioning: harmonised oil-resistant indoor control cable
ÖLFLEX 140 H05VV5-F should be positioned as a certified, harmonised and oil-resistant control cable for European machine and plant applications. It is especially relevant where the buyer needs a cable with the H05VV5-F designation and oil-resistant PVC sheath for dry, damp or wet interiors.
Recommended catalog description: ÖLFLEX 140 H05VV5-F is a harmonised PVC control cable according to EN 50525-2-51 with black numbered cores, fine-wire copper conductors and a grey high oil-resistance PVC outer sheath similar to RAL 7001. It is oil-resistant according to EN 50363-4-1: TM5 and suitable for plant engineering, industrial machinery, heating and air-conditioning systems and machine tools in indoor environments.
Important application note: The product is mainly used in dry, damp and wet interiors, including water-oil mixtures, but not for outdoor use. This distinction should be kept clear in product pages and selection guides.
2. CAD-style engineering section drawing
This vertical engineering illustration shows the ÖLFLEX 140 H05VV5-F construction: fine-wire copper conductors, black numbered PVC-insulated cores, layered twisting and grey high oil-resistance PVC outer sheath for machine and plant wiring.
| Pos. | Element | Material / specification |
|---|---|---|
| 1 | Grey high oil-resistance sheath | PVC outer sheath, high oil-resistance, grey, similar to RAL 7001 |
| 2 | TM5 oil-resistant layer logic | Oil-resistant according to EN 50363-4-1: TM5 for water-oil mixtures and machine-tool interiors |
| 3 | Layered core lay-up | Cores twisted in layers for flexible control-cable geometry |
| 4 | Black numbered cores | PVC core insulation; black with white numbers according to VDE 0293-334 |
| 5 | Protective conductor | G versions include GN-YE protective conductor |
| 6 | Fine-wire conductor | Bare copper wires, class 5 according to VDE 0295 / IEC 60228 |
3. Product make-up
4. Technical data
| Parameter | Value |
|---|---|
| Product type | Harmonised oil-resistant PVC control cable |
| Harmonised designation | H05VV5-F |
| ETIM 5.0/6.0 | Class-ID: EC000104; Class-Description: Control cable |
| Norm reference | EN 50525-2-51 |
| Oil resistance | According to EN 50363-4-1: TM5 |
| Core identification | Black with white numbers according to VDE 0293-334 |
| Conductor | Fine-wire strand made of bare copper wires |
| Conductor stranding | Fine wire according to VDE 0295, class 5 / IEC 60228 class 5 |
| Core insulation | PVC core insulation |
| Core lay-up | Cores twisted in layers |
| Outer sheath | PVC outer sheath, high oil-resistance, grey, similar to RAL 7001 |
| Nominal voltage | U0/U 300/500 V |
| Test voltage | 2000 V |
| Minimum bending radius | Occasional flexing: 12.5 x outer diameter; fixed installation: 4 x outer diameter |
| Temperature range | Occasional flexing: -5 °C to +70 °C; fixed installation: -40 °C to +70 °C |
| Flame-retardant | According to IEC 60332-1-2 |
| Protective conductor | G = with GN-YE protective conductor; X = without protective conductor |
| Product note | Trade product, no Lapp product |
5. Application range
Plant engineering
Suitable for plant wiring where harmonised European acceptance and oil resistance are required.
Industrial machinery
Designed for control circuits in industrial machinery with medium mechanical load conditions.
Machine tools
A strong use case due to oil resistance and suitability for water-oil mixtures in indoor machine environments.
HVAC systems
Applicable in heating and air-conditioning systems when an oil-resistant harmonised control cable is required.
Dry, damp and wet interiors
Mainly used in dry, damp and wet interiors, including water-oil mixtures.
Not for outdoor use
The application data explicitly excludes outdoor use, so outdoor routing should be avoided.
6. Product range from the provided data
| Article number | Number of cores and mm² per conductor | Outer diameter [mm] | Copper index [kg/km] | Weight [kg/km] |
|---|---|---|---|---|
| 0011000 | 3 G 0.5 | 5.5 – 7.0 | 14.4 | 62.4 |
| 0011104 | 4 G 0.5 | 6.2 – 7.9 | 19.2 | 68.2 |
| 0011001 | 5 G 0.5 | 6.8 – 8.6 | 24 | 87.1 |
| 0011002 | 7 G 0.5 | 8.3 – 10.4 | 33.6 | 118.7 |
| 0011003 | 12 G 0.5 | 10.4 – 12.9 | 58 | 198 |
| 0011004 | 18 G 0.5 | 12.3 – 15.3 | 86.4 | 266.9 |
| 0011005 | 25 G 0.5 | 14.8 – 18.3 | 120 | 380.4 |
| 0011006 | 34 G 0.5 | 17.2 – 21.2 | 163.2 | 509 |
| 0011009 | 3 G 0.75 | 6.0 – 7.6 | 21.6 | 75.6 |
| 0011204 | 4 G 0.75 | 6.6 – 8.3 | 28.8 | 83.9 |
| 0011010 | 5 G 0.75 | 7.4 – 9.3 | 36 | 113.3 |
| 0011011 | 7 G 0.75 | 9.0 – 11.3 | 50 | 145 |
| 0011012 | 12 G 0.75 | 11.0 – 13.7 | 86 | 244.9 |
| 0011013 | 18 G 0.75 | 13.2 – 16.4 | 130 | 327.7 |
| 0011014 | 25 G 0.75 | 15.8 – 19.5 | 180 | 466.4 |
| 0011015 | 34 G 0.75 | 18.4 – 22.6 | 245 | 626.5 |
| 0011241 | 41 G 0.75 | 20.1 – 24.7 | 296 | 748 |
| 0011018 | 3 G 1.0 | 6.3 – 8.0 | 28.8 | 89.3 |
| 0011304 | 4 G 1.0 | 6.9 – 8.7 | 38.4 | 98.6 |
| 0011019 | 5 G 1.0 | 7.8 – 9.8 | 48 | 132.1 |
| 0011020 | 7 G 1.0 | 9.5 – 11.8 | 67 | 169.3 |
| 0011021 | 12 G 1.0 | 11.8 – 14.6 | 115 | 285.9 |
| 0011022 | 18 G 1.0 | 14.0 – 17.2 | 173 | 405.2 |
| 0011023 | 25 G 1.0 | 16.8 – 20.7 | 240 | 569.5 |
| 0011024 | 34 G 1.0 | 19.6 – 24.0 | 326 | 741.7 |
| 0011341 | 41 G 1.0 | 21.4 – 26.2 | 394 | 886 |
| 0011027 | 3 G 1.5 | 7.4 – 9.4 | 43 | 109.8 |
| 0011404 | 4 G 1.5 | 8.2 – 10.2 | 58 | 140.7 |
| 0011028 | 5 G 1.5 | 9.1 – 11.4 | 72 | 175 |
| 0011029 | 7 G 1.5 | 11.3 – 14.1 | 101 | 224.2 |
| 0011030 | 12 G 1.5 | 13.8 – 17.0 | 173 | 361.7 |
| 0011031 | 18 G 1.5 | 16.5 – 20.3 | 259 | 518.3 |
| 0011032 | 25 G 1.5 | 19.8 – 24.3 | 360 | 729.9 |
| 0011033 | 34 G 1.5 | 23.1 – 28.2 | 490 | 946.6 |
| 0011036 | 3 G 2.5 | 9.0 – 11.2 | 72 | 162.4 |
| 0011504 | 4 G 2.5 | 10.1 – 12.5 | 96 | 203.3 |
| 0011037 | 5 G 2.5 | 11.0 – 13.7 | 120 | 251.1 |
| 0011038 | 7 G 2.5 | 13.6 – 16.8 | 168 | 326 |
| 0011039 | 12 G 2.5 | 16.8 – 20.6 | 288 | 553.3 |
| 0011045 | 14 G 2.5 | 18.3 – 22.7 | 336 | 611 |
| 0011040 | 18 G 2.5 | 20.2 – 24.8 | 432 | 795.2 |
| 0011041 | 25 G 2.5 | 24.2 – 29.6 | 600 | 1109.6 |
Unless specified otherwise, the shown product values are nominal values. Detailed values, such as tolerances, are available upon request. Copper price basis: EUR 150/100 kg. Standard packaging size is coil ≤ 30 kg or ≤ 250 m, otherwise drum. The preferred type of packaging can be specified, for example 1 × 500 m drum or 5 × 100 m coils.
7. Selection guide
| Selection criterion | Recommended check | Engineering meaning |
|---|---|---|
| Harmonised requirement | Check whether H05VV5-F or HAR acceptance is required | ÖLFLEX 140 offers high acceptance in Europe due to harmonisation. |
| Oil exposure | Check whether the cable route includes oil or water-oil mixtures | The cable is oil-resistant according to EN 50363-4-1: TM5. |
| Installation environment | Use in dry, damp and wet interiors only | The catalog application explicitly states not for outdoor use. |
| Movement condition | Use only fixed installation or occasional free movement without tensile load | Not intended for continuous compulsory-guided motion. |
| Protective conductor | Most listed versions are G versions with GN-YE protective conductor | Confirm the required conductor arrangement before ordering. |
| Bending condition | Use 12.5 x D for occasional flexing and 4 x D for fixed installation | Correct bending radius protects conductor and sheath geometry. |
8. Detailed feature interpretation
| Feature | Technical function | Practical benefit | Catalog wording |
|---|---|---|---|
| H05VV5-F harmonisation | Defines harmonised cable identity | High acceptance in Europe | Harmonised HAR: H05VV5-F |
| TM5 oil resistance | Defines oil-resistant PVC compound behavior | Suitable for machine-tool interiors and water-oil mixtures | Oil-resistant according to EN 50363-4-1: TM5 |
| Grey high oil-resistance sheath | Protects the laid-up core package | Good visual identity for indoor machinery wiring | PVC outer sheath, high oil-resistance, grey similar to RAL 7001 |
| Indoor wet area suitability | Supports use in dry, damp and wet interiors | Useful in plant and machine environments with fluids | Mainly used in dry, damp and wet interiors |
| Numbered cores | Supports circuit assignment and troubleshooting | Faster installation and clearer maintenance | Black with white numbers according to VDE 0293-334 |
| Class 5 conductor | Provides flexible conductor structure | Suitable for fixed installation and occasional flexing | Fine wire according to VDE 0295 / IEC 60228 class 5 |
9. SEO keyword matrix
Recommended Russian keyword clusters: ÖLFLEX 140, H05VV5-F, harmonised control cable, HAR control cable, маслостойкий кабель управления, кабель управления H05VV5-F, oil resistant PVC control cable, EN 50525-2-51 cable, EN 50363-4-1 TM5 cable, grey PVC control cable, кабель для станков, кабель для машиностроения, cable for machine tools, dry damp wet interiors cable, control cable 300/500 V, PVC sheath certified cable.
10. FAQ
What does H05VV5-F mean for this cable?
H05VV5-F is the harmonised designation. It supports high acceptance in Europe and identifies the cable as a harmonised oil-resistant PVC control cable.
Is ÖLFLEX 140 oil-resistant?
Yes. The cable is oil-resistant according to EN 50363-4-1: TM5.
Can ÖLFLEX 140 be used outdoors?
No. The application data states that it is mainly used in dry, damp and wet interiors, including water-oil mixtures, but not for outdoor use.
What is the outer sheath color?
The outer sheath is grey high oil-resistance PVC, similar to RAL 7001.
What is the test voltage?
The test voltage is 2000 V.
What bending radius should be used?
For occasional flexing, use 12.5 x outer diameter. For fixed installation, use 4 x outer diameter.