(N)SHÖU O/J Cable: Complete Technical Guide

HD FLEX 0,6/1 kV Round Reeling Cable Based on DIN VDE 0250 Part 812 for Highly Flexible Crane Festoon Systems

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
(N)SHÖU O/J Cable: Complete Guide to DIN VDE 0250-812 HD FLEX 0,6/1 kV Flexible Reeling Cables | Feichun Cables

(N)SHÖU O/J Cable: Complete Technical Guide

HD FLEX 0,6/1 kV Round Reeling Cable Based on DIN VDE 0250 Part 812 for Highly Flexible Crane Festoon Systems

📧 Email: [email protected]
📞 International Sales: +86 13855123218

The (N)SHÖU O/J cable represents a pinnacle of German engineering excellence in flexible power transmission technology. Manufactured in strict accordance with DIN VDE 0250 Part 812 standards, this highly flexible round reeling cable is specifically engineered for demanding industrial applications where extreme mechanical stress, continuous movement, and harsh environmental conditions are the norm.

1. What is (N)SHÖU O/J Cable?

The (N)SHÖU O/J designation refers to a specialized category of heavy-duty, rubber-sheathed flexible cables manufactured according to stringent German VDE (Verband der Elektrotechnik) standards. The nomenclature breaks down as follows:

  • (N) – Indicates national designation within German standardization framework
  • SHÖU – Designates heavy-duty rubber sheathed cable with special protective properties
  • O/J – Specifies the cable construction type and application category for mobile equipment

These cables are classified as HD FLEX (High Duty Flexibility) cables rated for 0,6/1 kV operation, making them ideal for medium voltage applications in industrial environments. The round reeling design facilitates smooth winding and unwinding on cable drums and festoon systems used in crane operations, mining equipment, and heavy machinery.

Key Definition

Round reeling cables are specifically designed with concentric round construction to prevent twisting and tangling during continuous winding/unwinding cycles on cable reels, essential for mobile equipment that requires reliable power transmission through dynamic motion.

2. Primary Purpose and Applications

The (N)SHÖU O/J cable serves critical functions in industrial environments where conventional cables would fail due to mechanical stress and environmental factors. Its primary applications include:

Industrial Applications

  • Mining Operations: Energy supply for equipment operating alongside conveyor belts, mobile mining machinery, and underground transportation systems where abrasion resistance and flame retardancy are critical safety requirements
  • Crane Festoon Systems: Power transmission to bridge cranes, gantry cranes, and overhead traveling cranes through festoon cable carrier systems that require continuous flexing during operation
  • Mobile Industrial Apparatus: Connection of movable production equipment, automated guided vehicles (AGVs), and robotic systems requiring flexible power supply throughout their operational range
  • Submersible Pump Applications: Power delivery to submersible pumps in mining dewatering, industrial wastewater treatment, and deep well applications where water and oil resistance is essential
  • Port and Harbor Equipment: Power supply for container handling cranes, ship-to-shore cranes, and mobile cargo handling equipment exposed to marine environments
  • Steel Mills and Foundries: High-temperature resistant power transmission for ladle cranes, casting cranes, and material handling equipment in extreme thermal environments

✓ Why Choose (N)SHÖU O/J Cables?

According to IEC (International Electrotechnical Commission) guidelines, rubber-sheathed flexible cables demonstrate superior performance in applications requiring resistance to mechanical abuse, temperature extremes, and chemical exposure compared to PVC-sheathed alternatives. The (N)SHÖU O/J specifically excels in continuous flexing applications with up to 2 million bending cycles under proper installation conditions.

3. Key Technical Characteristics

The (N)SHÖU O/J cable exhibits exceptional performance characteristics that distinguish it from standard industrial cables:

⚡ Electrical Performance

0,6/1 kV
Rated Voltage (U₀/U)

Suitable for 600V phase-to-ground and 1000V phase-to-phase applications with 3 kV test voltage verification

🔄 Mechanical Flexibility

Class 5
VDE 0295 / IEC 60228

Ultra-flexible conductor construction enabling tight bending radius for reeling applications

🔥 Flame Retardancy

IEC 60332-1-2
Certified Standard

Self-extinguishing properties prevent fire propagation in confined spaces and mining environments

🌡️ Temperature Range

-40°C to +90°C
Operational Range

Maintains flexibility and insulation integrity across extreme temperature variations

💪 Tensile Strength

15 N/mm²
Maximum Load

Superior tensile load capacity for vertical installations and self-supporting applications

🛢️ Chemical Resistance

IEC 60811-2-1
Oil & Ozone Resistant

Resists degradation from industrial oils, coolants, and atmospheric ozone exposure

Performance Advantages

  • Abrasion Resistance: Heavy-duty 5GM5 quality rubber sheath withstands continuous mechanical wear from festoon rollers and cable guides
  • Weather Resistance: Suitable for both indoor and outdoor installations without degradation from UV exposure, moisture, or temperature cycling
  • Low Temperature Flexibility: Maintains mechanical properties down to -40°C in static installations, crucial for cold climate operations
  • High Short Circuit Rating: 250°C maximum short circuit temperature provides safety margin during fault conditions
  • Optimal Bending Performance: Round construction enables smooth reeling without conductor separation or insulation cracking

4. Material Structure and Construction

The (N)SHÖU O/J cable features a sophisticated multi-layer construction designed to meet the demanding requirements of DIN VDE 0250 Part 812 specifications:

Layer-by-Layer Construction

ComponentMaterial SpecificationStandard ReferenceFunction
ConductorFlexible bare copper, Class 5VDE 0295 (IEC 60228)Current carrying element with maximum flexibility
Insulation3GI3 quality rubber compoundVDE 0207 Part 20Electrical insulation and mechanical protection
Core IdentificationColor-coded coresVDE 0293 Part 308 (HD 308)Phase and neutral identification
Inner SheathSpecial rubber compoundManufacturer specificationCore bundling and additional mechanical protection
Outer Sheath5GM5 quality heavy-duty rubberVDE 0207 Part 21Ultimate protection against abrasion, oil, and environmental factors

Conductor Construction Details

The Class 5 conductor classification under IEC 60228 represents the highest flexibility grade for copper conductors used in flexible cables:

  • Wire Diameter: Extremely fine copper wires (typically 0.10-0.21 mm diameter depending on conductor cross-section)
  • Strand Count: High number of individual strands (e.g., 1,050+ strands for 50 mm² conductor)
  • Stranding Configuration: Concentric or bunched construction for optimal flexibility and current distribution
  • Copper Purity: Minimum 99.9% pure electrolytic copper for superior conductivity (≥ 58 MS/m at 20°C)

Insulation Material Properties

The 3GI3 quality rubber compound specified in VDE 0207 Part 20 provides:

  • Dielectric Strength: High voltage withstand capability exceeding standard test requirements
  • Elasticity: Maintains flexibility over millions of bending cycles without cracking
  • Temperature Stability: Performs across -40°C to +90°C range without hardening or softening
  • Chemical Resistance: Resists degradation from oils, greases, and industrial chemicals

Outer Sheath Technology

The 5GM5 quality outer sheath (VDE 0207 Part 21) represents the most robust sheath material for industrial flexible cables:

5GM5 Material Properties

  • Hardness: Shore A durometer 60-70, providing optimal balance between flexibility and abrasion resistance
  • Tensile Strength: Minimum 8 N/mm² as per VDE requirements
  • Elongation at Break: Minimum 300% demonstrating exceptional elasticity
  • Tear Resistance: Superior resistance to notch propagation under stress
  • Ozone Resistance: No cracking after 96-hour exposure to 50 pphm ozone concentration

5. Compliance with International Standards

The (N)SHÖU O/J cable is manufactured in strict compliance with multiple international and German national standards, ensuring quality, safety, and interoperability:

Primary Compliance Standards

StandardTitle / ScopeCompliance Aspect
DIN VDE 0250-812Power cables with rated voltages up to 450/750 V – Part 812: Heavy duty cablesOverall cable design, construction, and performance requirements
VDE 0295 (IEC 60228)Conductors of insulated cablesConductor construction, cross-sections, and resistance values
VDE 0207-20Cables and flexible cords for power installation – Part 20: Rubber insulation compoundsInsulation material properties and testing
VDE 0207-21Cables and flexible cords for power installation – Part 21: Rubber sheath compoundsOuter sheath material requirements and performance
VDE 0293-308 (HD 308)Identification of cores in cables and flexible cordsColor coding system for phase conductors and neutral
VDE 0298-3Application of cables and cords in power installations – Part 3: Recommended minimum bending radiiInstallation parameters for mechanical design
VDE 0298-4Application of cables and cords in power installations – Part 4: Recommended values for current-carrying capacityCurrent rating calculations and derating factors
IEC 60332-1-2Tests on electric and optical fibre cables under fire conditions – Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flameFlame retardancy and fire safety characteristics
IEC 60811-2-1Common test methods for insulating and sheathing materials – Part 2-1: Methods specific to elastomeric compounds – Ozone resistance, hot set and mineral oil immersion testsOil resistance and ozone resistance verification

Certification and Testing

Each production batch of (N)SHÖU O/J cables undergoes rigorous testing according to VDE testing protocols:

  • Routine Tests: Voltage withstand test (3 kV AC for 5 minutes), conductor resistance measurement, dimensional verification
  • Type Tests: Mechanical tests (tensile strength, elongation, cold bend test), thermal aging, flame retardancy test, oil resistance test
  • Sample Tests: Ozone resistance (96 hours at 40°C), weather resistance exposure, abrasion resistance testing
  • Special Tests: Flexing endurance test (typically 10,000-50,000 cycles depending on application), heat shock test, low temperature impact test

Regulatory Compliance

For installations within the European Union, these cables comply with the Low Voltage Directive (LVD) 2014/35/EU and carry the CE marking. For North American applications, equivalent cables meeting UL or CSA standards should be specified.

6. Safety Thresholds and Ratings

Understanding and respecting the safety thresholds of (N)SHÖU O/J cables is critical for reliable operation and personnel safety:

Electrical Safety Parameters

ParameterValueSafety Consideration
Nominal Rated Voltage (U₀/U)0,6/1 kVNever exceed 1.2 kV AC or 1.8 kV DC under any operating condition
Test Voltage3 kV ACFactory test voltage; field testing should use lower voltages per VDE 0100
Maximum AC Operating Voltage0,7/1,2 kV20% overvoltage margin; prolonged operation at this level reduces service life
Maximum DC Operating Voltage1,8 kVFor DC applications, consult manufacturer for specific recommendations
Current RatingPer VDE 0298-4Depends on installation method, ambient temperature, and grouping; see derating factors

Thermal Safety Thresholds

Temperature ConditionValueSafety Implication
Maximum Conductor Temperature (Continuous)+90°CExceeding this temperature accelerates insulation aging and reduces cable life
Maximum Short Circuit Temperature+250°CMaximum 5-second duration; protective devices must clear faults within this time
Mobile Application Ambient Range-25°C to +80°CFor continuous flexing applications; static installations tolerate -40°C
Static Installation Ambient Range-40°C to +80°CFor fixed installations without mechanical movement

Mechanical Safety Parameters

Mechanical ParameterSpecificationSafety Notes
Minimum Bending RadiusPer VDE 0298-3Generally 15× outer diameter for flexible installations; tighter bends cause conductor damage
Maximum Tensile Load15 N/mm²Calculated on total phase conductor cross-section; never exceed during installation or operation
Maximum Vertical Unsupported LengthVaries by sizeConsult manufacturer; typically 10-30 meters depending on conductor cross-section

⚠️ Critical Safety Warning

Never exceed the maximum tensile load during installation or operation. Excessive tensile stress can separate conductor strands, damage insulation, and create potential shock hazards. Always use proper cable support systems and strain relief techniques. For vertical installations exceeding 20 meters, implement intermediate support points or use cables with integrated steel wire reinforcement.

Current Carrying Capacity

The current rating of (N)SHÖU O/J cables must be calculated according to VDE 0298 Part 4, considering:

  • Installation Method: Festoon system, cable reel, or direct burial affects heat dissipation
  • Ambient Temperature: Derating required for ambient temperatures exceeding 30°C
  • Grouping Factor: Multiple cables in close proximity require derating
  • Duty Cycle: Intermittent duty allows higher current ratings than continuous duty
  • Altitude: Installations above 1000m elevation require derating due to reduced air density

Example Current Rating Calculation

For a 3×25 mm² (N)SHÖU O/J cable in festoon system at 40°C ambient:

  • Base current rating: 125 A (per VDE 0298-4, reference method)
  • Temperature correction factor (40°C): 0.87
  • Grouping factor (single circuit): 1.0
  • Final rating: 125 A × 0.87 = 108.75 A

Note: This is an example only. Always consult VDE 0298-4 tables or manufacturer documentation for specific installations.

7. Installation and Usage Precautions

Proper installation and maintenance of (N)SHÖU O/J cables are essential for safe operation and maximum service life. Follow these critical precautions:

Pre-Installation Considerations

  • Storage Conditions: Store cable drums in dry, covered areas protected from direct sunlight. Maintain storage temperature between -10°C and +40°C. Do not stack drums more than 3 high to prevent deformation.
  • Visual Inspection: Before installation, inspect entire cable length for mechanical damage, cuts, or deformation. Any damaged section must be removed and properly terminated.
  • Temperature Acclimatization: If cable has been stored in cold conditions, allow it to acclimatize to ambient temperature for at least 24 hours before installation to prevent insulation cracking during handling.
  • Route Planning: Plan cable route to minimize the number of bends, avoid sharp edges, and ensure adequate support. Calculate total cable length including slack required for reeling systems.

Installation Guidelines

🔧 Mechanical Installation

  • Never pull cable around sharp corners or over rough surfaces
  • Use proper cable pulling grips that distribute force evenly
  • Monitor pulling tension; stop if resistance indicates obstruction
  • Support cable at intervals not exceeding 1.5 meters horizontally

📏 Bending Radius Compliance

  • Minimum static bend radius: 15× outer cable diameter
  • Minimum dynamic bend radius (reeling): 20× outer cable diameter
  • Use cable guides with smooth, rounded surfaces
  • Avoid reverse bends within 1 meter of each other

⚡ Electrical Connections

  • Use only approved compression or mechanical lugs
  • Clean conductor surfaces before termination
  • Apply proper torque values per manufacturer specifications
  • Ensure all connections are protected from moisture ingress

🛡️ Environmental Protection

  • Provide additional mechanical protection in areas with heavy traffic
  • Avoid contact with sharp metal edges or abrasive surfaces
  • Use appropriate cable entry systems for equipment enclosures
  • Ensure proper strain relief at all termination points

Festoon System Installation

For crane festoon applications, additional precautions apply:

  • Trolley Selection: Use festoon trolleys with roller diameters at least 10× cable outer diameter. Rollers must have smooth surfaces without burrs or sharp edges.
  • Cable Support: Support cable at each trolley position. Maximum spacing between trolleys: 1.5 meters for cables up to 25 mm², 1.0 meter for larger cables.
  • Loop Management: Form natural loops between trolleys without forced bending. Initial loop should allow for full travel range plus 10% margin.
  • Alignment: Ensure festoon track is straight and level. Misalignment causes uneven wear and premature cable failure.
  • Cable Entry: Use strain relief with smooth bend radius where cable enters mobile equipment. Never clamp cable rigidly at entry point.

Cable Reel Installation

For cable reel applications on mobile equipment:

  • Drum Diameter: Minimum drum diameter must be 20× cable outer diameter for round reeling applications
  • Spooling Method: Wind cable in even layers without crossing. First layer should be tight and uniform to prevent tangling in subsequent layers.
  • Tensioning: Maintain constant light tension during winding. Excessive tension damages conductors; insufficient tension causes loose coils and tangling.
  • Fleet Angle: Keep fleet angle (angle between cable and perpendicular to drum) below 2° to prevent side loading of cable.
  • End Connections: Use slip rings or collector assemblies rated for the full cable current capacity. Ensure proper maintenance of slip ring contacts.

Operational Precautions

⚠️ Do Not Operate If:

  • Outer sheath shows visible damage, cuts, or excessive wear
  • Cable has been subjected to over-current or short circuit conditions (requires inspection and testing)
  • Cable has been exposed to temperatures exceeding +90°C continuous or +250°C short circuit
  • Mechanical damage to conductors is suspected (perform insulation resistance test)
  • Cable has been contaminated with incompatible chemicals (strong acids, aromatic hydrocarbons)
  • Load Monitoring: Never exceed the calculated current rating. Install temperature monitoring systems for critical applications.
  • Environmental Monitoring: Be aware of ambient temperature changes that may affect current rating. Implement derating during heat waves.
  • Movement Monitoring: For mobile applications, track number of bending cycles. Plan replacement before reaching manufacturer’s specified cycle limit.
  • Inspection Schedule: Implement regular inspection program (see maintenance section below).

Maintenance Requirements

Maintenance TaskFrequencyProcedure
Visual InspectionWeeklyInspect for visible damage, excessive wear, deformation, or contamination
CleaningMonthlyRemove dust, oil accumulation, and contamination using soft cloth and mild detergent
Mechanical CheckMonthlyVerify cable support systems, strain relief integrity, and festoon trolley operation
Electrical TestingAnnuallyInsulation resistance test (500V DC megger), continuity verification, visual inspection of terminations
Comprehensive AssessmentEvery 3 yearsComplete electrical testing, mechanical flexing test, thermal imaging under load, replacement planning

Maintenance Best Practices

According to NFPA 70B (Recommended Practice for Electrical Equipment Maintenance), implementing a preventive maintenance program can extend cable service life by 40-60% and prevent costly unplanned downtime. Document all inspections and maintain detailed service records for each cable installation.

8. Common Problems and Solutions

Understanding common failure modes and their solutions helps ensure reliable operation of (N)SHÖU O/J cables:

Problem 1: Premature Insulation Cracking

Symptoms: Visible cracks in outer sheath or insulation, usually at points of mechanical stress

Root Causes:

  • Bending radius too small (below 15× outer diameter)
  • Installation at temperatures below -25°C without acclimatization
  • Exposure to incompatible chemicals (aromatic hydrocarbons, strong acids)
  • Excessive ozone concentration in industrial environments

Solutions:

  • Verify all installation bends meet minimum radius requirements using templates
  • Allow cable to reach ambient temperature before handling in cold weather
  • Review chemical exposure and specify alternate materials if necessary
  • In high ozone environments, inspect cables more frequently and plan earlier replacement
  • Replace damaged sections immediately; cracked insulation cannot be repaired

Problem 2: Conductor Strand Breakage

Symptoms: Increased conductor resistance, intermittent connection, visible conductor deformation

Root Causes:

  • Excessive tensile stress during installation or operation
  • Fatigue from excessive bending cycles beyond design limits
  • Improper support causing concentrated stress points
  • Cable overload causing thermal cycling and conductor work hardening

Solutions:

  • Never exceed 15 N/mm² tensile load; use proper pulling equipment with tension monitoring
  • Track bending cycles for reeling applications; replace cable before reaching service life limit
  • Add support points to reduce unsupported spans and stress concentrations
  • Verify current loading is within rated capacity; upgrade cable size if operating near maximum
  • For critical applications, implement predictive maintenance using conductor resistance trending

Problem 3: Excessive Heat Generation

Symptoms: Hot spots detectable by touch or thermal imaging, accelerated insulation aging, discoloration

Root Causes:

  • Current loading exceeds rated capacity for installation conditions
  • Poor electrical connections creating high resistance joints
  • Inadequate ventilation or heat dissipation in enclosed spaces
  • Unbalanced loading in three-phase systems

Solutions:

  • Measure actual current and verify against calculated rating with derating factors applied
  • Inspect and retorque all electrical connections to specified values
  • Improve ventilation around cables or reduce ambient temperature
  • Balance three-phase loads to prevent neutral conductor overloading
  • Consider upgrading to larger conductor cross-section if sustained overloading is required
  • Install temperature monitoring systems for early detection of thermal issues

Problem 4: Outer Sheath Abrasion

Symptoms: Visible wear on outer sheath surface, flat spots, exposure of inner layers

Root Causes:

  • Contact with rough surfaces or sharp edges during movement
  • Inadequate or worn festoon trolley rollers
  • Contamination with abrasive particles (sand, metal filings)
  • Incorrect cable selection for abrasion severity level

Solutions:

  • Inspect cable route for sharp edges and rough surfaces; add protection or modify path
  • Replace worn festoon trolley rollers; ensure rollers rotate freely without binding
  • Implement regular cleaning schedule to remove abrasive contamination
  • For severe abrasion environments, consider additional mechanical protection (conduit, cable carrier chains)
  • Replace cable when abrasion exposes inner sheath to prevent accelerated deterioration

Problem 5: Water Ingress and Corrosion

Symptoms: Reduced insulation resistance, corrosion of copper conductors, internal moisture

Root Causes:

  • Damaged cable ends not properly sealed
  • Cuts or punctures in outer sheath allowing water penetration
  • Submersion beyond design capability
  • Improper cable entry glands allowing moisture ingress

Solutions:

  • Ensure all cable ends are properly sealed using heat-shrink or appropriate glands
  • Replace sections with sheath damage; moisture will wick along conductor strands
  • For submersible applications, verify cable is specified for continuous immersion
  • Use IP67 or IP68 rated cable glands appropriate for the environment
  • Perform annual insulation resistance testing to detect moisture ingress early
  • If moisture detected, cable must be replaced; drying is not a permanent solution

Problem 6: Cable Twisting in Reeling Systems

Symptoms: Cable develops spiral twist, binding during reeling, uneven wear, premature failure

Root Causes:

  • Incorrect cable construction (non-round design used for reeling application)
  • Improper spooling technique during initial winding
  • Fleet angle exceeds 2°
  • Cable drum diameter too small causing internal stress

Solutions:

  • Verify cable is specified as “round reeling” type with concentric construction
  • Re-spool cable ensuring even, tight layers without crossing
  • Adjust cable guide position to maintain fleet angle below 2°
  • Replace drum with larger diameter unit (minimum 20× cable outer diameter)
  • Install swivel joint if application requires rotation along cable axis
  • Once cable develops permanent twist, it must be replaced; cannot be corrected

Troubleshooting Checklist

When investigating cable problems, follow this systematic approach:

  1. Visual Inspection: Examine entire cable length for obvious damage
  2. Electrical Testing: Measure insulation resistance (should exceed 1 MΩ), continuity, and conductor resistance
  3. Thermal Survey: Use infrared camera under load to identify hot spots
  4. Mechanical Assessment: Verify bending radii, support spacing, tensile loads
  5. Environmental Review: Check for chemical exposure, temperature extremes, abrasion sources
  6. Documentation Review: Verify installation was per specifications and maintenance was performed
  7. Root Cause Analysis: Determine underlying cause, not just symptom
  8. Corrective Action: Address root cause to prevent recurrence

9. Technical Specifications and Dimensions

Complete technical specifications for (N)SHÖU O/J cables manufactured by Anhui Feichun Special Cable Co., Ltd.:

Three-Core Configurations (3×X mm²)

Voltage
(kV)
Cores × Size
(Nr × mm²)
Conductor Ø
(mm)
Min Overall Ø
(mm)
Max Overall Ø
(mm)
Approx Weight
(kg/km)
Max Tensile Load
(N)
0,6/13×1,51,59,710,314168
0,6/13×2,51,911,111,7200113
0,6/13×42,413,213,8297180
0,6/13×62,914,415,0381270
0,6/13×103,817,418,5590450
0,6/13×164,819,520,6797720
0,6/13×256,123,724,812061125
0,6/13×357,226,627,716491575
0,6/13×508,931,833,021952250
0,6/13×7010,635,336,531243150
0,6/13×9512,340,942,641004275
0,6/13×12013,843,445,147235400
0,6/13×15015,547,849,559166750
0,6/13×18517,053,155,472718325

Three-Core Plus Ground Configurations (3×X + 3×Y/3 mm²)

Voltage
(kV)
Cores × Size
(Nr × mm²)
Conductor Ø
(mm)
Min Overall Ø
(mm)
Max Overall Ø
(mm)
Approx Weight
(kg/km)
Max Tensile Load
(N)
0,6/13×50 + 3×25/38,932,333,524812250
0,6/13×70 + 3×35/310,635,737,433193150
0,6/13×95 + 3×50/312,341,543,243244275
0,6/13×120 + 3×70/313,845,046,754765400
0,6/13×150 + 3×70/315,549,551,364686750
0,6/13×185 + 3×95/317,054,957,282988325
0,6/13×240 + 3×120/319,560,963,21047310800

Four-Core and Multi-Core Configurations

Voltage
(kV)
Cores × Size
(Nr × mm²)
Conductor Ø
(mm)
Min Overall Ø
(mm)
Max Overall Ø
(mm)
Approx Weight
(kg/km)
Max Tensile Load
(N)
0,6/14×1,51,510,511,117390
0,6/14×2,51,912,913,5274150
0,6/14×42,414,314,9356240
0,6/14×62,915,716,3459360
0,6/14×103,819,120,2729600
0,6/14×164,822,023,11038960
0,6/14×256,127,028,115761500
0,6/14×357,229,230,420782100
0,6/14×508,935,036,229673000
0,6/14×7010,638,840,539314200
0,6/14×9512,345,146,851655700
0,6/14×12013,850,051,861527200
0,6/14×15015,555,057,375379000
0,6/14×18517,061,063,3942011100

Five-Core and Higher Configurations

Voltage
(kV)
Cores × Size
(Nr × mm²)
Conductor Ø
(mm)
Min Overall Ø
(mm)
Max Overall Ø
(mm)
Approx Weight
(kg/km)
Max Tensile Load
(N)
0,6/15×1,51,511,412,0214113
0,6/15×2,51,914,014,6328188
0,6/15×42,415,616,2434300
0,6/15×62,917,518,6594450
0,6/15×103,820,922,0898750
0,6/15×164,824,125,212831200
0,6/15×256,129,630,819651875
0,6/17×1,51,514,515,1313158
0,6/17×2,51,916,817,4461263
0,6/112×1,51,516,817,4422270
0,6/112×2,51,919,520,6653450
0,6/118×1,51,519,420,5613405
0,6/118×2,51,923,324,4922675
0,6/124×1,51,520,922,0752540
0,6/124×2,51,925,226,31147900

📐 How to Read the Specifications

  • Voltage: Rated voltage in kV (U₀/U format where U₀ is phase-to-ground, U is phase-to-phase)
  • Cores × Size: Number of conductors and cross-sectional area in mm²
  • Conductor Ø: Individual conductor diameter in mm
  • Min/Max Overall Ø: Complete cable outer diameter range accounting for manufacturing tolerances
  • Approx Weight: Nominal weight per kilometer for logistics and support calculations
  • Max Tensile Load: Maximum allowable pulling force during installation (based on total conductor cross-section)

Selection Guide

When selecting the appropriate (N)SHÖU O/J cable configuration, consider:

  • Load Requirements: Calculate actual current demand including future expansion and apply appropriate derating factors
  • Voltage Drop: Verify voltage drop is within acceptable limits (typically 3-5% for power circuits)
  • Mechanical Space: Ensure festoon system or cable reel can accommodate the cable outer diameter
  • Weight Considerations: Verify support structures can handle cable weight over the full span
  • Bending Radius: Confirm available space allows for minimum 15-20× diameter bending radius
  • Future Proofing: Consider selecting next larger size for flexibility in future load increases

Need Expert Assistance with (N)SHÖU O/J Cable Selection?

Our technical team at Anhui Feichun Special Cable Co., Ltd. provides comprehensive support for cable selection, installation guidance, and custom manufacturing solutions. Contact us for detailed technical specifications, custom configurations, and application engineering support.

📧 Contact Technical Sales

International Sales: +86 13855123218

References and Standards Documentation

This guide is based on authoritative sources and internationally recognized standards:

📚 Recommended Reading

For additional technical information, consult the following standards documents:

  • DIN VDE 0250-812: Heavy duty rubber sheathed cables
  • IEC 60228: Conductors of insulated cables
  • IEC 60332-1-2: Vertical flame propagation tests
  • VDE 0298-4: Current-carrying capacity calculations
  • HD 308: Harmonized cable core identification

Anhui Feichun Special Cable Co., Ltd.

安徽飞纯特种电缆有限公司

Professional manufacturer of highly flexible cables for industrial applications

📧 Technical Support: [email protected]
📞 International Sales: +86 13855123218

© 2025 Anhui Feichun Special Cable Co., Ltd. All rights reserved.

This technical guide is provided for informational purposes. Always consult manufacturer specifications and relevant standards for specific installations.

Previous Article

What is the (N)TSCGEWOEU & (N)TSKCGEWOEU Highly Flexible Cables for Cable Reels

Next Article

What is a NSSHÖU O/J ...../3E.....+ST 0,6/1kV DIN VDE 0250 Part 812 approved Round Reeling Highly Flexible Cables for Cable Reels

View Comments (2)

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注