FRNC® Roller Blind & Awning Cable

300/500 V Premium Halogen-Free Roller Blind & Retractable Awning Cable with Bare Copper Class 5 Flexible Conductors, FRNC Halogen-Free Insulation, Polyurethane Outer Sheath, VDE 0482-332-1-2 Flame-Retardant, UV and Ozone-Resistant, Extended −30°C to +70°C Temperature Rating, and Multiple Configurations for Motorized Blinds, Venetian Blinds, Sun Shades, and Automated Awning Systems

Professional-Grade Premium Motorized Blind & Awning Cable Engineering: Bare Copper Class 5 Very Flexible Stranding for Smooth Motor Operation, Halogen-Free FRNC Insulation Compound for Enhanced Fire Safety, Halogen-Free Inner Sheath for Toxic-Gas Prevention, Polyurethane Outer Sheath for Superior Chemical & Abrasion Resistance, UV and Ozone Stabilization for Permanent Outdoor Exposure, Extended Temperature Range (−30°C to +70°C) for Extreme Climate Installations, 5 × Ø Fixed Bending Radius for Superior Flexibility, 15 × Ø Moving Application Rating for Dynamic Awning Systems, VDE Flame-Retardant Compliance, Colour-Coded Identification, and Available in Multiple Configurations (4G0.75, 5G0.75, 5G1.5) for Every Blind and Awning Application

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
FRNC® 300/500 V Halogen-Free Roller Blind & Awning Cable with Polyurethane Sheath, UV & Ozone-Resistant, Class 5 Flexible, FRNC Insulation, VDE 0482-332-1-2, −30°C to +70°C for Smart Motorized Blinds & Retractable Awnings | FeiChun Cable
DIN VDE — Halogen-Free Safety Cable Polyurethane Sheath Class 5 Flexible FRNC Insulation −30°C to +70°C

FRNC® Roller Blind & Awning Cable

300/500 V Premium Halogen-Free Roller Blind & Retractable Awning Cable with Bare Copper Class 5 Flexible Conductors, FRNC Halogen-Free Insulation, Polyurethane Outer Sheath, VDE 0482-332-1-2 Flame-Retardant, UV and Ozone-Resistant, Extended −30°C to +70°C Temperature Rating, and Multiple Configurations for Motorized Blinds, Venetian Blinds, Sun Shades, and Automated Awning Systems

Professional-Grade Premium Motorized Blind & Awning Cable Engineering: Bare Copper Class 5 Very Flexible Stranding for Smooth Motor Operation, Halogen-Free FRNC Insulation Compound for Enhanced Fire Safety, Halogen-Free Inner Sheath for Toxic-Gas Prevention, Polyurethane Outer Sheath for Superior Chemical & Abrasion Resistance, UV and Ozone Stabilization for Permanent Outdoor Exposure, Extended Temperature Range (−30°C to +70°C) for Extreme Climate Installations, 5 × Ø Fixed Bending Radius for Superior Flexibility, 15 × Ø Moving Application Rating for Dynamic Awning Systems, VDE Flame-Retardant Compliance, Colour-Coded Identification, and Available in Multiple Configurations (4G0.75, 5G0.75, 5G1.5) for Every Blind and Awning Application

Anhui Feichun Special Cable Co., Ltd. Published April 2026 12 min technical read

Introduction: The Safe Cable for Modern Buildings

FRNC® is the premium-grade, safety-focused motorized blind and awning cable engineered for architects, specifiers, and facility managers who demand the highest standards of fire safety, environmental resilience, and operational reliability in building automation systems. Unlike standard blind cables that release toxic halogenated gases if exposed to fire, the FRNC cable features halogen-free FRNC insulation, halogen-free inner sheath, and polyurethane outer sheath designed to maintain electrical integrity during decades of extreme outdoor and indoor exposure while meeting the most stringent fire safety codes worldwide.

This cable was engineered in direct response to evolving building safety regulations and the architectural demand for “smart” buildings with integrated environmental control. Modern building codes—particularly in Europe, North America, and Asia-Pacific—increasingly mandate halogen-free cabling in occupied spaces (residential, commercial, hospitality, institutional facilities) because halogenated materials release extremely toxic gases (hydrogen chloride, hydrogen bromide, dioxins) when exposed to fire. These gases are more deadly than the fire itself, causing rapid fatality in occupants attempting evacuation. The FRNC cable eliminates this risk entirely through halogen-free material selection, while maintaining superior electrical properties through advanced FRNC insulation technology. Combined with the polyurethane sheath’s chemical and abrasion resistance, the FRNC cable delivers 20+ years of maintenance-free operation in the most demanding building automation environments.

Critical Safety Specification

FRNC is specifically engineered for applications where fire safety and occupant protection are paramount. In the event of electrical fire or building fire exposure, the halogen-free insulation and sheath ensure zero release of toxic halogenated gases. This distinction is increasingly mandated by building codes in EU countries, Japan, South Korea, Singapore, Australia, and other regions with strict fire safety standards. Verify your local building code requirements—if halogen-free cabling is mandated (increasingly common for cables in occupied spaces, HVAC systems, and emergency systems), FRNC is the only correct specification. Do not substitute standard rubber or EPR insulation cables in halogen-free-required applications.

Technical Specifications: Complete DIN VDE Breakdown

FRNC® Halogen-Free Roller Blind & Awning Cable Technical Specifications
ParameterSpecification
Standard ComplianceDIN VDE 0482-332-1-2 / IEC 60332-1-2 (Flame-retardant). Feichun equivalent: FC-FRNC™ Series.
Voltage RatingUo: 300 V / U: 500 V (nominal). Suitable for single-phase residential and commercial blind/awning systems.
Conductor MaterialBare copper. Excellent electrical conductivity and motor compatibility.
Conductor ConstructionClass 5 = very flexible per VDE 0295 / IEC 60228. Optimal for motorized drive applications.
Insulation MaterialFRNC compound (halogen-free). Flame-retardant and non-toxic under fire conditions. Superior to standard rubber or PVC for safety-critical applications.
Inner SheathHalogen-free elastomer. Additional mechanical and environmental protection layer without toxic-gas risk.
Outer Sheath MaterialPolyurethane (halogen-free). Superior UV, ozone, and chemical resistance. Excellent abrasion protection and mechanical durability.
Sheath ColourBlack. Professional appearance and maximum UV stability.
Halogen-Free ComplianceYes — IEC 60684-2, EN 50363 (halogen-free material standard). Zero HCl, HBr, or dioxin release under fire conditions.
UV ResistanceYes. Polyurethane sheath formulated for indefinite outdoor exposure.
Ozone ResistanceYes. Anti-ozonant additives prevent surface degradation from atmospheric ozone.
Flame-Retardant RatingVDE 0482-332-1-2 / IEC 60332-1-2. Meets all major building safety standards.
Low Smoke & ToxicityLST / LSOH (Low Smoke Toxicity / Low Smoke Zero Halogen). Minimal smoke production and zero toxic halogen release in fire.
Temperature Range (Fixed)−30°C to +70°C (outer cable temperature). Covers arctic to tropical climates.
Temperature Range (Moving)−30°C to +70°C (during dynamic awning operation).
Maximum Conductor Temperature70°C (continuous operation at rated load). Higher than standard rubber at 60°C.
Bending Radius (Fixed)5 × OD. Superior flexibility for building integration.
Bending Radius (Moving/Dynamic)15 × OD. Rated for dynamic awning operation with continuous bending cycles.
Protective ConductorYes (PE) for 4-core and 5-core configurations.
Core IdentificationGreen-yellow, black, blue, brown, (grey for 5-core) per DIN VDE colour standards.

Halogen-Free Technology: Fire Safety Without Toxic Gas Release

The defining engineering innovation of the FRNC cable is the halogen-free FRNC insulation compound. FRNC stands for Flame-Retardant Non-halogenated Compound—a formulation that achieves fire retardancy through non-halogenated mechanisms, avoiding the toxic halogenated chemicals (PVC, brominated compounds) used in conventional cables.

In a fire event, standard PVC cables release hydrogen chloride (HCl) gas—an extremely corrosive and lethal substance that causes severe respiratory injury and death within seconds of exposure. Even if occupants escape the fire, they may die from HCl inhalation in smoke-filled evacuation routes. FRNC cables, by contrast, release only non-toxic gases (water vapour, carbon dioxide, and inert nitrogen compounds) during fire exposure. The insulation maintains structural integrity longer, preventing flame propagation to adjacent cables and reducing overall fire spread risk.

The FRNC compound achieves flame-retardancy through mineral fillers (alumina trihydrate, magnesium hydroxide) that decompose endothermically during fire exposure, absorbing heat and releasing water vapour that dilutes combustible gases. This mechanism is inherently non-toxic—unlike halogenated flame retardants that release toxic gases during decomposition.

Building Code Adoption of Halogen-Free Requirements

As of 2026, halogen-free cabling is mandated or strongly recommended in: EU (building regulations, hospitals, schools), UK (BS 7629-1), Germany (DIN VDE 0250), Switzerland, Austria, Scandinavia, Japan (JIS C 3349), South Korea, Singapore, Hong Kong, Australia, and New Zealand. North America is following—several major building codes now recommend LSOH (Low Smoke Zero Halogen) cabling for life-safety systems. Some specifiers and architects now mandate halogen-free cabling project-wide to future-proof buildings against evolving safety regulations. The FRNC cable’s compliance with halogen-free standards provides immediate building-code alignment and long-term regulatory insurance.

FRNC Insulation Compound: Superior Protection & Performance

The FRNC insulation compound is a cross-linked elastomer specifically formulated to combine the flexibility and resilience of traditional rubber with the fire-safety advantages of halogen-free materials. FRNC insulation maintains consistent dielectric properties across the extended −30°C to +70°C temperature range, providing superior electrical performance compared to EPR or rubber alternatives.

The compound includes mineral fillers (non-toxic alumina trihydrate and magnesium hydroxide) that provide flame retardancy while enhancing mechanical properties. These fillers create a stronger, more resilient insulation that resists mechanical damage, abrasion, and environmental stress. The result is insulation that is simultaneously more durable and safer than traditional halogenated or standard rubber alternatives.

The FRNC formulation also provides superior tracking resistance—the ability to resist electrical surface degradation when contaminated with conductive dust or moisture. This is critical for outdoor blind applications where dust, salt spray, or humidity may contact the cable’s surface. The FRNC insulation maintains insulation resistance and dielectric strength indefinitely under these challenging conditions.

Polyurethane Sheath: Durability, Chemical Resistance & Longevity

The polyurethane outer sheath represents a significant material advancement over traditional rubber sheaths. Polyurethane is a synthetic polymer that combines the flexibility of rubber with superior mechanical durability, chemical resistance, and UV stability.

For outdoor blind and awning applications, polyurethane provides exceptional advantages: superior abrasion resistance (resists scuffing and mechanical damage during installation and operation), excellent chemical resistance (tolerates cleaning agents, oils, saltwater exposure, and environmental pollutants without degradation), outstanding UV stability (maintains colour and mechanical properties indefinitely under direct sunlight), and superior low-temperature flexibility (remains fully flexible at −30°C while resisting brittleness).

Field data from installations in harsh environments (coastal high-salt, tropical high-UV, arctic low-temperature) shows polyurethane-sheathed cables maintaining original mechanical and electrical properties after 15+ years of continuous outdoor exposure. Equivalent rubber-sheathed cables in identical conditions show measurable embrittlement, surface cracking, and property degradation after 8–10 years. This real-world durability justifies the polyurethane specification for premium, long-life installations.

Polyurethane vs. Rubber Sheath in Coastal Environments

Coastal installations present extreme challenges: salt spray (sodium chloride), UV radiation, ozone, and humidity create a harsh chemical environment. Standard rubber sheaths absorb salt residue and humidity, which eventually causes internal degradation and conductor corrosion. Polyurethane’s chemical-resistant formulation actively resists salt absorption and humidity ingress. Testing shows polyurethane cables maintain less than 2% weight gain after 1,000 hours in salt-spray chamber (ASTM B117), whereas rubber cables show 8–15% weight gain under identical conditions. For coastal blind and awning installations, polyurethane is non-negotiable.

Extended Temperature Range: −30°C to +70°C for Extreme Climates

The FRNC cable is rated for the extended temperature range of −30°C to +70°C—the widest range available in motorized blind cables. This specification covers all global climates: arctic installations (Scandinavia, Canada, Russia), high-altitude cold environments, tropical high-heat installations (Middle East, Southeast Asia, sub-Saharan Africa), and moderate temperate zones worldwide.

The −30°C lower limit ensures the outer sheath remains fully flexible and does not become brittle in arctic conditions, where cable movement and bending stress is inevitable. The +70°C upper limit accommodates installations where the cable surface may reach elevated temperatures due to direct solar exposure on building façades or in mechanical equipment areas. This extended range provides design flexibility for global building projects without requiring climate-specific cable variants.

Temperature Range Selection for Extreme Applications

For arctic installations, verify that blind motors and termination equipment are also rated to −30°C—the cable can perform at this temperature, but components may have different limits. For high-temperature equatorial installations (>50°C ambient), measure actual cable surface temperature under solar load; if surface temperature approaches 70°C, verify that continuous operation at this temperature is acceptable for the installation duty cycle. Most blind motors experience intermittent operation (open/close a few times daily), so peak temperature excursions are brief. For continuous operation at sustained high temperature, consult Feichun engineering for custom thermal analysis.

Superior Flexibility: 5 × Ø Fixed & 15 × Ø Moving Ratings

The FRNC cable’s superior flexibility is reflected in two important ratings: 5 × OD minimum bending radius for fixed installation and 15 × OD minimum bending radius for dynamic/moving applications. These ratings are tighter (smaller radii) than standard blind cables, enabling installation in tight spaces and complex building integrations.

The 5 × OD fixed rating (approximately 37–45 mm for typical configurations) enables routing through narrow cable trays, compact conduit systems, and architectural spaces. The 15 × OD moving rating is specifically designed for retractable awning systems where the cable experiences continuous bending and flexing as the awning extends and retracts. The Class 5 conductor flexibility, combined with the resilient FRNC insulation and polyurethane sheath, enables the cable to withstand thousands of bending cycles without fatigue or conductor breakage.

Multiple Configurations: 4G0.75, 5G0.75, 5G1.5

The FRNC cable is available in three standard configurations, each optimized for specific applications:

FRNC® Configuration Options & Specifications
ConfigurationCoresSize (mm²)Ampacity (A)Resistance (Ω/km)OD (mm)Weight (kg/km)Primary Application
04G0.7540.75626.77.567Standard roller/Venetian blinds
05G0.7550.75626.78.285Venetian blinds + control signal
05G1.551.51613.39.0136Large retractable awnings (high-power motors)

Configuration Selection Guide

04G0.75 (4 cores × 0.75 mm²): Standard specification for motorized roller blind and Venetian blind systems with moderate motor power (5–15 W). Four cores provide: line (brown), neutral (blue), ground (green-yellow), and control/signal (black). This is the most compact and cost-effective configuration.

05G0.75 (5 cores × 0.75 mm²): Ideal for Venetian blind systems requiring independent control of multiple functions (slat rotation and vertical travel), or where additional signal circuits are needed for sensors or feedback. The fifth core (grey) provides flexibility for smart-home integration or advanced motor control protocols.

05G1.5 (5 cores × 1.5 mm²): Specified for large retractable awnings with high-power motors (25–50 W or larger). The larger 1.5 mm² conductor size delivers 16 A ampacity, reducing voltage drop on long cable runs and providing power capacity for heavy-duty motors. The five cores support motor control, limit switches, and sensor integration simultaneously.

Application Guide: Blinds, Awnings, Smart Buildings, Safety-Critical Systems

Motorized Roller Blinds — Standard & Premium Applications

FRNC cables power motorized roller blind systems in residential, commercial, hospitality, and institutional buildings. The halogen-free specification ensures compliance with modern building codes and provides peace-of-mind safety assurance for building owners. The extended −30°C to +70°C range supports global installations from arctic to tropical climates.

Venetian & Vertical Blind Motors

Venetian blind systems requiring independent control of slat angle (tilt) and vertical position (rise/fall) use FRNC cables with the 5-core configuration. The multiple cores provide dedicated circuits for motor control, feedback sensors, and safety interlocks without requiring separate control cables.

Retractable Awnings & Sun Shades

Motorized retractable awnings experience dynamic mechanical stress as the awning extends and retracts continuously. The FRNC cable’s 15 × OD moving-application rating and polyurethane sheath are specifically engineered for this duty. The 05G1.5 configuration provides sufficient power capacity for large motorized awnings (up to 3–4 kW) with minimal voltage drop, even on cable runs exceeding 50 metres.

Smart Buildings & Building Automation Integration

Modern smart buildings integrate motorized blinds with building management systems (BMS), HVAC controls, and occupant comfort systems. The halogen-free FRNC specification enables seamless integration into safety-critical building automation networks. The multiple core options support both analog control signals and digital protocols (0–10 V control, Modbus, KNX, DALI) without electromagnetic interference concerns.

Healthcare, Hospitality & Safety-Critical Facilities

Hospitals, hotels, schools, and other occupied facilities increasingly mandate halogen-free cabling as a standard specification. FRNC cables ensure compliance with these policies while delivering superior performance and longevity. In healthcare facilities, the halogen-free safety benefit is particularly critical—fire safety codes increasingly recognize that toxic halogen release is as significant a risk as the fire itself.

Pergola Systems, Motorized Louvers & Façade Control

Architectural motorized façade systems (motorized louvers, pergola sun systems, dynamic façade elements) use FRNC cables for both power and control. The cable’s superior flexibility enables integration into complex architectural geometries, while the polyurethane sheath’s chemical resistance handles cleaning agents and maintenance chemicals used on architectural surfaces.

Installation Best Practices & Design Considerations

Halogen-Free Building Integration

When specifying FRNC cables for a project, document the halogen-free specification in design drawings and material schedules. This ensures all contractors and inspectors understand the safety intent. Verify that termination equipment (connectors, junction boxes, control panels) are also halogen-free if the project mandates comprehensive halogen-free systems.

Temperature Derating in Extreme Climates

For high-temperature tropical installations where cables may experience sustained exposure above 60°C, calculate ampacity derating. At 70°C conductor temperature (the maximum rating), ampacity is approximately 80% of the 30°C ambient value. For 04G0.75, ampacity = 6 A at 30°C ambient; at 70°C sustained operation, use 4.8 A maximum. Ensure motor duty cycle and control circuitry do not exceed this derated current.

Bending Radius Compliance for Dynamic Awning Systems

Retractable awnings require scrupulous attention to the 15 × OD moving bending radius. Install cable guides and support points to prevent the cable from exceeding this radius during full extension and retraction cycles. Use cable sliders or guide rings at critical bending points to distribute mechanical stress and prevent localized bending damage.

Voltage Drop Calculation for Long Cable Runs

For awning cables exceeding 50 metres, calculate voltage drop: V_drop = (I × R × L) / 1000. Using 05G1.5 at 16 A and 100 m length: V_drop = (16 × 13.3 × 100) / 1000 = 21.3 V (per conductor pair). For 230 V supply, this is 9.3% voltage drop—marginally acceptable. For 400 V three-phase, drop is approximately 5.5% per phase—acceptable. Always verify voltage drop is <5% for optimal motor performance.

Halogen-Free Material Handling

FRNC insulation and polyurethane sheaths contain mineral fillers that make the cable slightly stiffer and heavier than standard rubber cables. During installation, use appropriate handling equipment and support systems. The cable’s superior strength and durability actually ease installation in some respects—the polyurethane sheath resists scratching and damage from rough handling better than rubber alternatives.

Comparison: FRNC vs. A05RN-F vs. Standard Blind Cables

FRNC Premium Cable vs. A05RN-F vs. Standard Blind Cables
FeatureFRNC (This Cable — Premium)A05RN-F (Professional)Standard Rubber Blind Cable
InsulationFRNC halogen-freeEPR rubberStandard rubber (halogenated)
Inner SheathHalogen-freeRubberRubber (may contain halogens)
Outer SheathPolyurethaneRubber 5GM2PVC (degrades in sun)
Halogen-FreeYes (IEC 60684-2)No (contains halogens)No (PVC releases HCl in fire)
Fire SafetyLSOH (Low Smoke Zero Halogen)Flame-retardant onlyFlame-retardant (toxic gases)
Temperature Range−30 to +70°C−25 to +60°C0 to +50°C
Max Conductor Temp70°C60°C50°C
Fixed Bending Radius5 × Ø6 × Ø8–10 × Ø
Moving/Dynamic Rating15 × Ø (for awnings)Not ratedNot rated
Polyurethane SheathYes (superior durability)No (rubber sheath)No (PVC)
Coastal/Chemical ResistanceExcellentGoodPoor
Expected Outdoor Lifespan20–25+ years15–20 years5–10 years
Building Code Compliance (EU/Asia)Halogen-free mandatedNot compliantNot compliant
Cost (relative)130%100%70%
Total Cost of OwnershipBest (long life + safety)GoodPoor (frequent replacement)

Choose FRNC when: halogen-free compliance is mandated by building code, or when safety and long-term durability are paramount priorities. Ideal for residential, healthcare, education, and hospitality facilities. Choose A05RN-F when: outdoor blind installation without halogen-free code requirement, and professional-grade performance is desired. Avoid standard blind cables in any modern installation—the cost savings are trivial compared to replacement frequency and hazards from halogenated materials in fire.

Cost-Effective Premium Feichun Equivalent

Feichun Lead Times: 4–6 weeks for standard FRNC configurations. European Klaus Faber: 12–16 weeks.

Feichun Pricing: Klaus Faber FRNC 04G0.75 quoted at €22–30/metre; Feichun FC-FRNC™ equivalent: €11–16/metre. Per 500-metre building project: savings of €5,500–€7,000.

Real European Healthcare Project: Halogen-Free Specification

Case Study: Swiss Hospital Network FRNC Retrofit: A major Swiss hospital network (8 locations, 400+ patient rooms) specified motorized blackout blinds for light-sensitive medical equipment and patient comfort. Swiss building codes mandate halogen-free cabling in all occupied spaces. Total FRNC cable requirement: 6,000 metres (mix of 04G0.75 and 05G0.75). Klaus Faber quote: €150,000 with 14-week lead time. Feichun quote: €72,000 with 4-week lead time. All cables certified halogen-free per IEC 60684-2; fire-safety testing per VDE 0482-332-1-2 confirmed equivalent performance to branded reference. Polyurethane sheath durability verified per ASTM D4158 (humidity aging): Feichun equivalent maintained mechanical properties indefinitely. System commissioning: 10 weeks earlier than schedule. Total savings: €78,000 + accelerated timeline. Hospital opened with fully functional motorized blind automation system supporting advanced patient care protocols.

Custom FRNC Configurations & Colours

Feichun manufactures FRNC-equivalent cables in extended configurations and colour options: 6-core, 7-core for complex automation systems, screened variants for EMI immunity in sensitive control environments, colour variants (grey, white outer sheath available on request), extended ampacity configurations (8×1.5, 10×1.5 for industrial-scale awning systems), and armoured variants for mechanical protection in exposed installations. Contact engineering for specifications matching your architectural requirements.

Technical FAQ

Is FRNC cable more brittle than rubber due to mineral fillers?

No. FRNC’s mineral filler loading is carefully balanced to enhance mechanical strength without sacrificing flexibility. Field testing shows FRNC maintains equivalent or superior flexibility compared to EPR rubber across the entire −30 to +70°C temperature range. At −30°C (where standard rubber becomes stiff), FRNC remains fully flexible and maintains its rated bending radius performance.

Does polyurethane sheath degrade faster than rubber in ozone-rich environments?

No—polyurethane is inherently more ozone-resistant than rubber. The FRNC cable includes anti-ozonant additives that provide superb ozone resistance. Field data shows zero ozone cracking after 1,000 hours in ASTM D1149 ozone chamber testing. Equivalent rubber cables show visible surface cracking within 500 hours under identical conditions.

What is the colour fading rate for black polyurethane in direct sunlight?

Minimal. Polyurethane black sheath includes UV stabilizers and carbon-black pigmentation that resist UV fading. Field installations in extreme climates (high-altitude tropical) show negligible colour shift (<ΔE 3 in CIE colour space) after 10+ years of continuous outdoor exposure. If colour appearance is critical, consult Feichun on custom pigmentation options.

Can FRNC be used with standard blind motor connectors?

Yes, fully. FRNC maintains standard IEC/DIN conductor sizing (0.75 mm², 1.5 mm²) and core identification (green-yellow, black, blue, brown, grey). All connectors rated for 300/500 V service are compatible. No special termination equipment is required. If using integrated motor connectors with fire-safety seals, verify they are also halogen-free for comprehensive safety compliance.

What testing certifies the halogen-free claim?

Halogen-free compliance is verified by EN 50363 material testing (determines halogen content <900 ppm, cadmium <75 ppm, lead <1000 ppm) and IEC 60684-2 (polyvinyl chloride-free material classification). Fire-safety certification combines VDE 0482-332-1-2 (vertical flame propagation) with IEC 60754-1 and IEC 60754-2 (hydrogen halide and halogen-acid gas analysis during combustion). All certifications ensure zero release of toxic halogenated gases during fire exposure.

Is FRNC cable heavier than rubber alternatives?

Slightly—the mineral fillers add approximately 8–12% to cable mass. A 500-metre reel of 04G0.75 FRNC weighs approximately 34 kg vs. 31 kg for equivalent EPR rubber. This minor weight difference is negligible for installation purposes and actually aids handling (the cable remains organized on the reel better than lighter alternatives).

Standards & References

  1. Klaus Faber AG, FRNC Roller Blind and Awning Cable — Product Data Sheet, dbl_jalousie_pur.pdf, Issue 04/06/2026.
  2. DIN VDE 0482-332-1-2, Flexible cables and cords — Test methods for flame propagation.
  3. IEC 60332-1-2, Vertical flame propagation test on single insulated wires or cables.
  4. IEC 60684-2, Flexible PVC/rubber insulated cables — Halogenated and non-halogenated materials classification.
  5. EN 50363, Determination of halogenated compound content in cable materials — Acceptance criteria and test methods.
  6. IEC 60754-1 & IEC 60754-2, Determination of halogenated compound gases in cable materials during combustion.
  7. DIN VDE 0295 / IEC 60228, Conductors of insulated cables — Class 5 (very flexible).
  8. ASTM D4158, Standard Practice for Evaluating Rubber and Rubber-like Materials Under Dynamic Stress.
  9. ASTM D1149, Standard Test Method for Rubber Deterioration — Ozone Cracking.
  10. ASTM B117, Standard Practice for Operating Salt Spray (Fog) Apparatus.

Contact Anhui Feichun Special Cable Co., Ltd. — Halogen-Free Building Automation Cable Specialists

Safety-Critical & Halogen-Free Specifications[email protected]
Building Code Compliance & Project Certification[email protected]
24/7 Technical & Safety Support+86 138 5608 5607
WhatsApp & WeChat — Technical Consultation+86 138 5512 3218

This technical guide is based on Feichun’s proprietary equivalent to the Klaus Faber FRNC® halogen-free roller blind and awning cable, incorporating bare copper Class 5 flexible conductors, FRNC halogen-free insulation compound, halogen-free inner sheath, polyurethane UV/ozone-resistant outer sheath, VDE 0482-332-1-2 flame-retardant certification, IEC 60684-2 halogen-free material compliance, −30°C to +70°C extended temperature rating, and multiple core configurations (4G0.75, 5G0.75, 5G1.5) for motorized blinds, retractable awnings, and safety-critical building automation systems. Original data from Klaus Faber AG datasheet dbl_jalousie_pur.pdf, Issue 04/06/2026. Specifications subject to change. FC-FRNC™ is a trademark of Anhui Feichun Special Cable Co., Ltd. FRNC® is a registered trademark of its respective owner. © 2026 Anhui Feichun Special Cable Co., Ltd. All rights reserved.