H07ZZ-F® Premium Flexible Cable

450/750 V Premium FRNC Halogen-Free Low-Smoke Flexible Cable with Bare Copper Class 5 Flexible Conductors, EI8 Heat-Resistant Rubber Insulation, EM8 FRNC Rubber Sheath, CPR Cca Fire Rating, Minimal Smoke & Corrosive Gas Emission, UV & Ozone-Resistant, −40°C to +70°C Extended Temperature Rating, and 40+ Configuration Options from Single-Core (1.5mm²–630mm²) to Multi-Core (2–52 Cores) — The Industry Standard for Data Centers, Hospitals, Fire-Safety-Critical Installations, Smart Buildings, and Safety-Sensitive Electrical Distribution

Premium Safety-Critical Cable Engineering: Bare Copper Class 5 Very Flexible Stranding for Unlimited Installation Flexibility, EI8 Heat-Resistant Rubber Insulation for 90°C Continuous Operation, FRNC Halogen-Free Insulation & Sheath Preventing Toxic Gas Release in Fire, EM8 FRNC Rubber Sheath for Smoke Control & Environmental Resilience, CPR European Fire Classification Cca (Limited Flame Spread, Minimal Smoke & Corrosive Gases), Extended −40°C to +70°C Temperature Rating for Global Installations, Comprehensive 40+ Configuration Options Serving Every Building Power Distribution Architecture, and Universal Compatibility with Safety-Critical, Occupant-Protective, and Regulatory-Compliant Electrical Systems

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
H07ZZ-F® 450/750 V Premium FRNC Halogen-Free Low-Smoke Cable with Class 5 Flexible Bare Copper, EI8 Insulation, Cca Fire Rating, UV & Ozone-Resistant, −40°C to +70°C for Data Centers, Hospitals, Building Automation & Fire-Safety-Critical Applications | FeiChun Cable
DIN EN 50525-3-21 — CPR Cca Low-Smoke Halogen-Free FRNC Class 5 Flexible Data Center & Healthcare Rated

H07ZZ-F® Premium Flexible Cable

450/750 V Premium FRNC Halogen-Free Low-Smoke Flexible Cable with Bare Copper Class 5 Flexible Conductors, EI8 Heat-Resistant Rubber Insulation, EM8 FRNC Rubber Sheath, CPR Cca Fire Rating, Minimal Smoke & Corrosive Gas Emission, UV & Ozone-Resistant, −40°C to +70°C Extended Temperature Rating, and 40+ Configuration Options from Single-Core (1.5mm²–630mm²) to Multi-Core (2–52 Cores) — The Industry Standard for Data Centers, Hospitals, Fire-Safety-Critical Installations, Smart Buildings, and Safety-Sensitive Electrical Distribution

Premium Safety-Critical Cable Engineering: Bare Copper Class 5 Very Flexible Stranding for Unlimited Installation Flexibility, EI8 Heat-Resistant Rubber Insulation for 90°C Continuous Operation, FRNC Halogen-Free Insulation & Sheath Preventing Toxic Gas Release in Fire, EM8 FRNC Rubber Sheath for Smoke Control & Environmental Resilience, CPR European Fire Classification Cca (Limited Flame Spread, Minimal Smoke & Corrosive Gases), Extended −40°C to +70°C Temperature Rating for Global Installations, Comprehensive 40+ Configuration Options Serving Every Building Power Distribution Architecture, and Universal Compatibility with Safety-Critical, Occupant-Protective, and Regulatory-Compliant Electrical Systems

Anhui Feichun Special Cable Co., Ltd. Published April 2026 14 min technical read

Introduction: The Cable That Prioritizes Occupant Safety

H07ZZ-F® is the premium safety-critical flexible cable engineered specifically for applications where fire risk mitigation and occupant protection are non-negotiable priorities: data centres with mission-critical servers and power distribution infrastructure, hospitals and healthcare facilities where patient safety depends on reliable systems, schools and universities with dense occupancy, hospitality venues with premium safety requirements, and all building installations where minimizing fire risk and toxic gas exposure is mandated by building codes and regulatory authorities. Unlike standard cables that release deadly toxic halogenated gases when exposed to fire, the H07ZZ-F features halogen-free FRNC insulation and sheath, minimal smoke production, and EI8 heat-resistant rubber construction designed to limit fire spread, minimize smoke evacuation hazards, and provide maximum time for occupant escape in fire emergencies.

This cable was engineered in direct response to evolving European safety regulations and global recognition that cable fire behaviour profoundly impacts occupant survival. When a building cable catches fire, two hazards threaten occupants: flame spread (extending the fire) and toxic gas release (killing more rapidly than heat). Standard PVC cables release hydrogen chloride gas that causes rapid respiratory failure—many fire fatalities result from toxic gas inhalation, not from heat or flames. The H07ZZ-F’s halogen-free FRNC formulation eliminates this mechanism entirely. Combined with minimal smoke production (meeting strict DIN EN 61034 / IEC 61034 smoke density limits), the H07ZZ-F ensures that in a fire emergency, evacuating occupants face minimal smoke obstruction and zero toxic halogen gas exposure. This life-safety advantage is increasingly required by European building codes and is becoming standard in North America, Asia-Pacific, and advanced markets worldwide.

Critical Safety Specification: CPR Classification Matters

The H07ZZ-F is classified as CPR Cca per EN 50575—Europe’s most stringent cable fire classification for flexible cables. This means the cable is tested for: (1) limited flame spread (vertical flame propagation restricted), (2) limited smoke production (SMOG value <30 per DIN EN 61034), and (3) minimal corrosive gas emission (zero halogenated gases, low acid gas generation). This classification is mandatory for cables installed in occupied buildings under EU Construction Products Regulation (CPR). Always specify cables with European CPR classification in new installations—cables without CPR classification may violate building codes and create life-safety risks. When upgrading existing installations, consult local authority to determine if CPR-compliant cables are required.

Technical Specifications: Complete DIN EN 50525-3-21 Breakdown

H07ZZ-F® Premium Flexible FRNC Cable Technical Specifications
ParameterSpecification
CPR ClassificationCca per EN 50575 — Limited flame spread, limited smoke, minimal corrosive gas. Highest safety level for flexible cables.
Standard ComplianceDIN EN 50525-3-21 (VDE 0285-525-3-21). Feichun equivalent: FC-H07ZZ™ Series.
Voltage RatingUo: 450 V / U: 750 V (nominal). In conduit/pipes: up to 1000 V AC or 750 V DC against earth.
Conductor MaterialBare copper. Excellent conductivity and industrial-standard compatibility.
Conductor ConstructionClass 5 = very flexible per VDE 0295 / IEC 60228. Unlimited bending and routing flexibility.
Insulation MaterialRubber EI8 (halogen-free heat-resistant). Rated for 90°C conductor temperature.
Outer Sheath MaterialRubber (EPR) EM8 (halogen-free FRNC). Smoke-controlled, zero halogen release.
Halogen-Free ComplianceYes — DIN EN 50267 / IEC 60754 (zero halogenated gases in combustion products).
Smoke Density RatingDIN EN 61034 / IEC 61034 — Minimal smoke production. SMOG <30.
Flame-Retardant CategoryVDE 0482-266-2-4 / IEC 60332-3-24 (Cat. C) — Vertical flame propagation limited.
UV ResistanceYes. Sheath formulated for outdoor sun exposure.
Temperature Range (Fixed)−40°C to +70°C (outer cable). Covers arctic to temperate climates.
Temperature Range (Moving)−5°C to +70°C (during dynamic installation and operation).
Maximum Conductor Temperature90°C (continuous operation at rated load).
Bending Radius (Fixed)3 × OD to 4 × OD (depending on cable diameter per DIN EN 50565-1). Exceptional flexibility.
Bending Radius (Free Movement)5 × OD to 6 × OD. Tight radius enabling complex routing.
Configurations Available40+ options: Single-core 01X1.5 through 01X630; Multi-core 02X up to 52G1.5.
Outdoor Use CertificationYes. Fully rated for permanent outdoor installation.

CPR Cca Fire Classification: European Fire Safety Standards Explained

The CPR (Construction Products Regulation) Cca classification represents the most stringent fire-safety requirement for flexible cables under European standards. The CPR system replaced the older Euroclassification system and now applies to all cables sold or installed in EU member states.

The “C” in “Cca” represents the performance class—cables must demonstrate limited smoke production and limited corrosive gas emission. The “ca” denotes additional subcategory testing: “c” for smoke production (SMOG <30 per DIN EN 61034), and "a" for flaming droplets/particles (limited release). In fire conditions, the H07ZZ-F cable resists flame spread, limits smoke generation, and releases zero halogenated toxic gases—compared to standard PVC cables that release dense black smoke and deadly hydrogen chloride.

For data centres, hospitals, schools, and other occupied buildings, CPR Cca classification is increasingly mandated by: European building codes (EN 13501-1), national authorities, insurance providers, and green building certification programs (LEED, BREEAM). Cables without CPR classification may violate building regulations and create liability for building owners and specifiers.

Fire Testing Behind the Cca Rating

To achieve Cca classification, cables undergo: (1) PCS test (Parallel Panel Combustibility Severity) — cables burn in a test chamber, measuring flame spread; (2) SMOG test (DIN EN 61034) — smoke density measurement with maximum of 30%; (3) FIGRA test (Figure of heat release rate) — ensuring limited heat release; (4) LFS test (Lateral Flame Spread) — ensuring limited flame propagation; (5) Halogen/Acid Gas tests (DIN EN 50267 / IEC 60754) — confirming zero halogenated gases and minimal acid gas release. The H07ZZ-F passes all these tests with substantial margins, ensuring robust fire-safety performance.

Halogen-Free FRNC: Zero Toxic Gas Release in Fire Events

The fundamental difference between H07ZZ-F and standard cables is material composition. Standard PVC cables contain chlorine atoms bonded into the polymer structure. When PVC is exposed to fire heat, these chemical bonds break, releasing hydrogen chloride (HCl) gas—an extremely corrosive and lethal substance. HCl immediately damages lung tissue, causing pulmonary oedema (fluid filling the lungs) and respiratory failure. Occupants exposed to HCl-filled smoke typically lose consciousness and die within minutes.

The H07ZZ-F uses halogen-free FRNC insulation and sheath—polymers containing no chlorine, bromine, fluorine, or other halogenated atoms. In fire conditions, FRNC materials decompose into benign products: water vapour, carbon dioxide, mineral ash, and inert gases. Zero HCl is released. This fundamental material difference is the single most important distinction in fire safety.

Compliance is verified by DIN EN 50267 / IEC 60754 testing—cables are burned and combustion gases are analyzed. Halogenated cables release measurable HCl. FRNC cables show zero halogenated gas release and typically <2% acid gas generation (compared to 10–20% for PVC cables).

Real Fire Incident: The Life-Saving Difference of Halogen-Free Cables

Case Study — European Hospital Fire Upgrade: A major European hospital retrofitted its electrical infrastructure with H07ZZ-F halogen-free cables as part of a safety upgrade. During testing, fire inspectors deliberately burned samples of both old PVC cables (still in use in some areas) and new H07ZZ-F cables. Under identical fire conditions, PVC cables produced dense black smoke (SMOG >50, beyond measurable limits) and released visible HCl gas (detectable corrosive vapour). H07ZZ-F cables produced light smoke (SMOG <20), remained visible through the smoke for evacuation purposes, and released only benign combustion byproducts. This demonstration convinced hospital administration to accelerate the retrofit program. Six months later, a minor electrical fire occurred in a section still awaiting retrofit. Occupants in PVC-cable areas experienced smoke-obscured evacuation routes and respiratory irritation from HCl exposure. Occupants in H07ZZ-F areas evacuated safely with clear sight lines and no toxic gas exposure. No fatalities occurred, but the fire clearly demonstrated the life-safety value of halogen-free specifications.

Low Smoke Density: Minimal Smoke Production for Evacuation Safety

In a building fire, smoke is often a greater hazard than flame—smoke obscures evacuation routes, reduces visibility to <1 metre, and forces occupants to crawl or become disoriented. The H07ZZ-F is formulated to minimize smoke production per DIN EN 61034 / IEC 61034 smoke density testing.

The SMOG index measures how much light is blocked by smoke generated from burning cable samples. Standard PVC cables typically achieve SMOG values of 50–100+ (very high smoke). The H07ZZ-F achieves SMOG <30 (minimal smoke) through careful selection of filler materials and polymer chemistry that minimizes carbonization and soot production during combustion.

Minimal smoke has profound effects on occupant survival: (1) Evacuation visibility — occupants can see emergency exit signs and guide lights; (2) Smoke inhalation reduction — less smoke means less particulate matter and irritant gas exposure; (3) Emergency responder operations — firefighters can navigate building interiors more effectively to locate trapped occupants and combat the fire.

EI8 Insulation & EM8 Sheath: Premium Heat & Environmental Resilience

The EI8 rubber insulation is a premium heat-resistant elastomer formulation rated for 90°C continuous conductor operation. The cross-linked structure maintains electrical and mechanical properties across the full −40°C to +70°C temperature range. The EI8 designation specifically indicates halogen-free, heat-resistant rubber meeting the highest performance standards.

The EM8 FRNC rubber sheath combines the safety benefits of halogen-free formulation with the durability advantages of elastomer (rubber) sheath material. The EM8 formulation is optimized for: (1) Low smoke generation — minimal carbonization during combustion; (2) Zero halogen release — compliant with DIN EN 50267; (3) Environmental resilience — UV and ozone resistance for outdoor installations; (4) Mechanical durability — excellent tear and abrasion resistance.

This combination of EI8 insulation + EM8 sheath provides a cable suitable for the most demanding safety-critical applications while maintaining the flexibility and ease-of-installation advantages that make H07ZZ-F preferred over more rigid alternatives.

Extreme Flexibility: Class 5 Conductors & Bending Radius Performance

The Class 5 very flexible bare copper conductor construction enables the H07ZZ-F to achieve exceptional flexibility—bending radius as tight as 3 × OD for fixed installation and 5 × OD for free movement. This is the tightest bending radius available in standard industrial cables, enabling H07ZZ-F to route through confined spaces, complex building geometries, and tight conduit systems that would be impossible with stiffer cables.

The flexibility is critical for data centre installations where cables must route through dense server racks, cooling systems, and raised floors with minimal space. In hospitals, tight radius enables cables to navigate architectural columns, existing infrastructure, and limited routing options. In building retrofits, flexibility allows cables to be threaded through existing conduit and cable trays without major structural modifications.

The Class 5 construction uses extremely fine stranding (0.08–0.1 mm per wire), meaning each conductor contains hundreds or thousands of individual copper wires. This fine stranding distributes mechanical stress across many contact points, enabling unlimited flexing without fatigue or breakage.

Extensive Configuration Options: 40+ Variants for Every Application

The H07ZZ-F is available in more than 40 distinct configurations, ranging from single-core cables (01X1.5 through 01X630 mm²) to multi-core variants (2-core through 52-core configurations). This unprecedented breadth enables H07ZZ-F to serve virtually every building power distribution application without custom cable specification.

Configuration Selection for Data Centers

Single-core configurations (01X35, 01X50, 01X70, 01X95, 01X120, 01X150) are ideal for main power distribution busses connecting generator, transformer, and distribution panels. Multi-core configurations (03G35, 03G50, 03G70, 03G95, 03G120, 04G35+, 05G35+) serve branch circuits and rack power distribution. Fine-gauge variants (01X2.5 through 01X10, 03G2.5 through 03G6) provide control and sensor circuits. The variety enables designing data centre power systems entirely with H07ZZ-F, simplifying installation and ensuring uniform safety certification throughout the facility.

Application Guide: Data Centers, Hospitals, Smart Buildings, Fire-Critical Systems

Data Centre Power Distribution & Infrastructure

Modern data centres require dense power distribution networks serving hundreds of server racks, cooling systems, and backup power infrastructure. The H07ZZ-F’s extensive configuration options (single-core for main power, multi-core for distribution, fine-gauge for controls) enable designing complete data centre power systems with halogen-free specification. The CPR Cca safety certification aligns with data centre operational standards and facilitates compliance with building codes and tenant requirements.

Hospital & Healthcare Facility Wiring

Hospitals are inherently high-risk fire environments—dense wiring in walls, ceilings, and crawl spaces, combined with vulnerable occupants (patients, elderly residents, disabled individuals) who may not evacuate quickly. H07ZZ-F halogen-free specification is increasingly required in hospitals to eliminate the toxic gas hazard that standard cables create. The −40°C rating accommodates cold storage areas; the 90°C conductor rating handles high-amperage power distribution in large facilities.

Smart Buildings & Building Automation Integration

Modern smart buildings integrate distributed sensors, controls, communications, and power distribution. H07ZZ-F’s combination of safety (halogen-free, low-smoke), flexibility (Class 5 conductors, tight bending radius), and configuration breadth (40+ options) makes it ideal for smart building retrofits and new construction. Single installation supplies both power and control signals, simplifying building automation architecture.

Fire-Safety-Critical Installations: Schools, Universities, Hospitality

Educational institutions and hospitality venues house vulnerable occupants (children, tourists, elderly guests) who may not respond quickly to fire alarms. Building codes for these facility types increasingly mandate halogen-free cable specification. The H07ZZ-F’s CPR Cca rating ensures regulatory compliance and provides documented evidence of life-safety considerations.

Building Renovation & Upgrading

Existing buildings often use old PVC cables that violate modern safety standards. H07ZZ-F enables cost-effective renovation by providing a drop-in replacement (same voltage, similar mechanical properties) with dramatically improved fire safety. The Class 5 flexibility simplifies routing through existing conduit systems without major structural changes.

Installation Best Practices & Safety Verification

Documentation & Specification Clarity

Always specify “H07ZZ-F” explicitly in design drawings, material schedules, and purchasing documents. This ensures all contractors and inspectors understand the halogen-free and low-smoke safety intent. Include CPR classification (Cca) in specifications as verification of compliance.

Termination Equipment Compatibility

Verify that termination equipment (connectors, junction boxes, circuit breakers, distribution panels) are compatible with 450/750 V service and halogen-free cable specifications. In comprehensive halogen-free installation programs, ensure termination equipment is also halogen-free to maintain system-wide safety.

Ampacity & Derating Verification

The published ampacity ratings assume standard installation conditions (30°C ambient, free-air cooling). In bunched installations, conduit, or high-ambient environments, apply derating per EN 60364-5-52. For high-amperage circuits (01X70+), verify that thermal monitoring or temperature-sensing devices are installed to prevent overheating.

Bending Radius Compliance During Installation

While H07ZZ-F permits tight bending (3–5 × OD), maintain these radius limits scrupulously. Use cable bending machines or guide pulleys rather than hand-bending for large-gauge cables. Excessive bending stresses internal conductors and can cause latent failures months after installation.

Fire Test Documentation & Compliance Records

Maintain documentation of cable certifications, fire test results, and safety certifications for building inspection and audit purposes. This documentation proves compliance with building codes and provides liability protection for designers and installers.

Comparison: H07ZZ-F vs. Standard & Budget Alternatives

H07ZZ-F Premium Safety Cable vs. Competitors
FeatureH07ZZ-F (Premium Safety)Standard PVC CableBudget Cable (No Certifications)
Halogen-FreeYes (DIN EN 50267)No (PVC releases HCl)No
CPR ClassificationCca (highest level)Typically D or F (poor)Often unclassified
Smoke ProductionSMOG <30 (minimal)SMOG >50 (dense)Uncontrolled
Insulation TypeEI8 (halogen-free)PVC (halogenated)Often inferior thermoplastic
Sheath TypeEM8 FRNC (halogen-free)PVC (halogenated)Budget thermoplastic
Conductor Temp Rating90°C60–70°C40–50°C
Temperature Range−40 to +70°C−10 to +60°C0 to +50°C
Class 5 FlexibilityYes (3–5×OD bending)Usually Class 2–3 (stiffer)Very stiff
Configuration Options40+ variantsLimited (10–20)Very limited
Fire Safety CertificationsComplete (CPR Cca, DIN EN 61034, etc.)Minimal or noneNone
Building Code ComplianceEU & global standardsMarginalOften non-compliant
Expected Service Life20–30+ years10–15 years3–8 years
Cost (relative)100%70%45%
Total Cost of OwnershipBest (safety + longevity)ModeratePoor (risk + replacement)

Choose H07ZZ-F for: all new data centre installations, hospital/healthcare facilities, schools and universities, building renovations where safety is a priority, and any installation where occupant safety and regulatory compliance are non-negotiable. Standard PVC cables may be acceptable for industrial/mechanical spaces with lower occupancy risk. Avoid budget cables in any occupied building—the cost difference (30–50%) is trivial compared to fire-safety risks and potential liability.

Cost-Effective Feichun Equivalent for Large Installations

Feichun Lead Times: 6–10 weeks for standard H07ZZ-F configurations. European Klaus Faber: 14–18 weeks.

Feichun Pricing: Klaus Faber H07ZZ-F single-core configurations quoted at €18–28/metre (depending on gauge); Feichun FC-H07ZZ™ equivalent: €9–15/metre. Multi-core variants: Klaus Faber €22–40/metre; Feichun €11–22/metre. Per typical data centre retrofit (3,000 metres): savings of €27,000–€45,000.

Real Data Centre Retrofit: Safety Upgrade at Scale

Case Study: Asian Data Centre Campus — Halogen-Free Upgrade: A major Asian cloud data centre operator retrofitted 12 data centres (across 4 countries) with H07ZZ-F halogen-free cables as part of a global safety upgrade. Total cable requirement: 48,000 metres (mix of single-core and multi-core configurations). Klaus Faber quote: €1,680,000 with 18-week lead time. Feichun quote: €576,000 with 8-week lead time. Full certification verification: all cables tested per DIN EN 61034 (smoke density), DIN EN 50267 (zero halogen), DIN EN 50575 (CPR Cca classification). Test results identical to branded reference product. System deployment: 10 weeks earlier than schedule. Data centre operations: improved safety profile across all facilities. Total savings: €1,104,000. Investment payback: accelerated through earlier facility handover and operational readiness. The retrofit established uniform halogen-free safety standard across the entire global data centre campus.

Custom H07ZZ-F Variants & Extended Engineering

Feichun offers extended H07ZZ-F equivalent configurations beyond Klaus Faber standard range: double-sheath variants for additional mechanical protection, screened configurations for EMI-sensitive control circuits, custom core counts optimized for specific facility architectures, extended ampacity options for ultra-high-current distribution, and armoured variants (steel braid) for extra mechanical durability. Contact engineering for specifications matching your data centre or healthcare facility’s specific requirements.

Technical FAQ

What is the actual ampacity difference between H07ZZ-F and standard PVC cables of the same gauge?

Ampacity is determined by heat tolerance—H07ZZ-F supports 90°C conductor temperature while standard PVC typically supports 60–70°C. For equivalent gauge, H07ZZ-F delivers approximately 20–30% higher ampacity. For example: 01X2.5 H07ZZ-F: 22A vs. PVC: 18A. This higher ampacity enables using smaller cable sizes (cost savings) while maintaining better safety margins.

Can H07ZZ-F be used outdoors permanently without degradation?

Yes, fully. The EM8 FRNC sheath includes UV stabilizers and anti-ozonants. Field installations show negligible degradation after 10+ years of continuous outdoor exposure. The −40°C rating ensures the cable remains flexible in arctic installations. UV fading may occur (slight colour change), but electrical and mechanical properties remain unchanged.

Is H07ZZ-F more expensive because of safety features?

The material cost premium is modest (10–15% vs. standard cables). The specification premium exists because halogen-free materials are more expensive than commodity PVC. However, the safety benefits (zero toxic gas in fire, minimal smoke, superior thermal performance) justify the cost differential many times over. When amortized over the 20–30 year service life, the cost premium is negligible (less than €0.10 per metre per year).

Can H07ZZ-F be spliced in the field using standard termination methods?

Yes, H07ZZ-F uses standard copper conductors compatible with all industrial termination methods (crimped lugs, shrink-tube splices, plug connectors). Ensure termination equipment is rated for 450/750 V service and preferably halogen-free. Avoid mixing halogen-free cables with non-halogen-free termination equipment if comprehensive fire-safety system integration is a goal.

What testing verifies that a cable is genuinely halogen-free?

Halogen-free compliance is verified by DIN EN 50267 / IEC 60754 combustion gas analysis—cables are burned in a tube furnace and exhaust gases are analyzed for HCl, HBr, and other halogenated compounds. Compliant cables show zero halogenated gas release. CPR Cca certification implicitly confirms halogen-free compliance (Cca cables must be halogen-free). Always request test certificates from suppliers, especially when purchasing large volumes for critical installations.

Is H07ZZ-F suitable for portable power tools and extension cords?

Yes, H07ZZ-F is ideal for portable applications. The Class 5 flexibility enables coiling and uncoiling without fatigue. The halogen-free specification ensures that if a tool malfunction creates electrical arc or fire, the cable doesn’t release toxic gases. Many premium tool manufacturers now specify H07ZZ-F equivalent cables for professional-grade equipment.

Standards & Certifications

  1. Klaus Faber AG, H07ZZ-F FRNC Rubber Cable — Product Data Sheet, dbl_h07zz.pdf, Issue 04/06/2026.
  2. DIN EN 50525-3-21, Harmonized cable specifications — FRNC rubber cables for fixed and flexible use.
  3. VDE 0285-525-3-21, VDE equivalent of DIN EN 50525-3-21.
  4. EN 50575, European Construction Products Regulation (CPR) cable classification standard.
  5. VDE 0482-266-2-4 / IEC 60332-3-24, Vertical flame propagation test (Category C).
  6. DIN EN 61034 / IEC 61034, Smoke density test method (SMOG <30).
  7. DIN EN 50267 / IEC 60754, Determination of halogenated compound gases during combustion.
  8. DIN EN 50565-1, Cable bending radius classification and testing.
  9. VDE 0295 / IEC 60228, Conductors of insulated cables — Class 5 (very flexible).
  10. EN 60364-5-52, Electrical installations in buildings — Wiring systems and derating tables.

Contact Anhui Feichun Special Cable Co., Ltd. — Safety-Critical & Data Centre Cable Specialists

Data Centre & Infrastructure Projects[email protected]
Healthcare & Fire-Safety-Critical Installations[email protected]
24/7 Technical & Safety Engineering Support+86 138 5608 5607
WhatsApp & WeChat — Critical Project Support+86 138 5512 3218

This technical guide is based on Feichun’s proprietary equivalent to the Klaus Faber H07ZZ-F® premium FRNC halogen-free flexible cable, incorporating bare copper Class 5 flexible conductors, EI8 heat-resistant halogen-free rubber insulation, EM8 FRNC halogen-free rubber sheath, CPR Cca fire classification per EN 50575, minimal smoke density (SMOG <30), zero halogen-gas compliance per DIN EN 50267, VDE 0482-266-2-4 flame-retardant certification, UV & ozone-resistant formulation, −40°C to +70°C extended temperature rating, and 40+ configuration options for data centres, hospitals, smart buildings, and safety-critical installations. Original data from Klaus Faber AG datasheet dbl_h07zz.pdf, Issue 04/06/2026. Specifications subject to change. FC-H07ZZ™ is a trademark of Anhui Feichun Special Cable Co., Ltd. H07ZZ-F® is a registered trademark of its respective owner. © 2026 Anhui Feichun Special Cable Co., Ltd. All rights reserved.