
What is TENAX-LUMEN (N)TSCGH3S 3,6/6KV Mining Trailing Cable?
Table of Contents
Introduction to TENAX-LUMEN Mining Cable
In the demanding world of mining operations, safety and reliability are paramount concerns. The TENAX-LUMEN (N)TSCGH3S 3,6/6KV represents a breakthrough in mining cable technology, combining advanced electrical engineering with innovative luminescent properties to create a safer working environment for mining personnel and equipment.
Manufactured by Prysmian Group, a global leader in energy and telecommunications cable systems, this specialized trailing cable addresses one of the mining industry’s most persistent challenges: cable visibility in low-light or dark conditions. The cable is engineered to power large mobile equipment such as draglines and shovels in both surface and underground mining operations.
Purpose and Applications
Primary Applications
The TENAX-LUMEN cable is specifically designed for trailing applications in the mining industry, where it serves several critical functions:
- Power Supply to Mobile Equipment: Delivers reliable electrical power to large mining machinery including electric shovels, draglines, and excavators operating in surface mines
- Safety Enhancement: Provides continuous visibility in dark environments, preventing accidental cable damage from crushing, cutting, or impact by mobile equipment
- 24/7 Operations: Enables round-the-clock mining operations by ensuring cables remain visible during night shifts and in poorly lit areas
- Emergency Situations: Maintains visibility during power outages or equipment failures, facilitating safe evacuation and emergency response
Why Cable Visibility Matters
According to mining safety reports, cable damage from crushing by equipment represents one of the most common causes of trailing cable failures in surface mining operations. Poor visibility during night operations or in dark underground environments significantly increases the risk of equipment running over cables, leading to costly downtime, equipment damage, and serious safety hazards including electrical fires and electrocution risks.
Key Characteristics and Features
🌟 Self-Illuminating Technology
Active electroluminescent strings embedded beneath transparent sheath provide continuous visibility even when cable is not energized
❄️ Extreme Temperature Operation
Fully flexible operation from -50°C to +60°C in mobile applications, suitable for Arctic and extreme climate conditions
💪 Superior Durability
Extremely robust polyurethane outer sheath resistant to abrasion, tearing, oils, ozone, and UV radiation
🔥 Fire Safety
Halogen-free and flame retardant according to EN/IEC 60332-1-2 standards, ensuring safe operation in confined spaces
⚡ High Voltage Capability
Rated for 3.6/6 (7.2) kV operation with conductor temperatures up to 90°C continuous and 250°C short circuit
🔄 Maximum Flexibility
Highly stranded copper conductors enable tight bending radius and repeated flexing during dragline and shovel operations
Luminescent System Specifications
The innovative illumination system that sets TENAX-LUMEN apart from conventional mining cables operates on the following principles:
| Parameter | Specification |
|---|---|
| Maximum Voltage | 125 V AC |
| Maximum Frequency | 2000 Hz (optimal: 800-1300 Hz) |
| Current Absorption | ~15 A/km |
| Heat Development | None |
| Light Homogeneity | > 95% |
| Irradiation Coverage | 360° (full circumference) |
Material Structure and Cable Design
The TENAX-LUMEN cable features a sophisticated multi-layer construction designed to withstand the extreme mechanical and environmental stresses encountered in mining operations:
Layer-by-Layer Construction
- Conductor Core: Finely stranded tinned copper conductors (Class 5 per IEC 60228) providing maximum flexibility and corrosion resistance. Available in sizes ranging from 35 mm² to 240 mm² with additional ground and pilot conductors
- Inner Semiconductive Layer: Special semiconductive EPR (Ethylene Propylene Rubber) compound applied directly over conductors to ensure uniform electrical field distribution
- Core Insulation: Special EPR rubber compound (3GI3) providing excellent electrical insulation, ozone resistance, and flexibility. This material maintains its properties across the full temperature range
- Outer Semiconductive Layer: Semiconductive NBR (Nitrile Butadiene Rubber) easy-strip layer that facilitates cable termination and jointing
- Cable Core Assembly: Cores are laid up around a semiconductive central filler with aramid yarn reinforcement, providing mechanical strength and maintaining cable geometry under stress
- Electroluminescent Strings: Special high-visibility, low-power consumption electroluminescent strings are positioned in the outer interstices of the cable core, providing 360-degree illumination
- Outer Sheath: Transparent special-compound polyurethane (PUR) outer sheath that allows the luminescent elements to be visible while providing exceptional mechanical protection, abrasion resistance, and environmental durability
Available Configurations
The cable is manufactured in various configurations to suit different equipment power requirements:
| Construction | Conductor Size | Cable Diameter | Weight |
|---|---|---|---|
| 3×35+3×25/3 | 7.5 mm | 45.2-48.5 mm | 3100 kg/km |
| 3×70+3×35/3 | 10.6 mm | 52-56 mm | 4650 kg/km |
| 3×95+2×25+1×16 | 12.6 mm | 58.9-63.4 mm | 5750 kg/km |
| 3×150+2×35+1×16 | 16 mm | 68.8-72.4 mm | 8350 kg/km |
| 3×240+2×70+1×16 | 20.3 mm | 74.3-78.3 mm | 12000 kg/km |
Compliance with International Standards
The TENAX-LUMEN cable is manufactured and tested according to rigorous international standards, ensuring reliability and safety in demanding mining environments:
- DIN VDE 0250-813: German standard for power cables with rated voltages up to and including 450/750 V
- DIN EN 60228 / IEC 60228 / VDE 0295: Conductors of insulated cables – specifications for conductor construction and resistance
- DIN EN 60332-1-2 / IEC 60332-1-2: Tests on electric and optical fiber cables under fire conditions – vertical flame propagation test for single insulated wire or cable
- IEC 60754-2: Test on gases evolved during combustion of materials from cables – determination of acidity (by pH measurement) and conductivity
- DIN VDE 0298-4: Use of cables and insulated cords for power installation – recommended current-carrying capacity for cables and flexible cords
- DIN EN 60811-404 / IEC 60811-404: Insulating and sheathing materials of electric and optical cables – common test methods – measurement of insulation resistance
- GOST-R/-K/-BF: Fire Certificate of Russian Federation for compliance with fire safety requirements
Certification Significance
These certifications ensure the cable meets stringent requirements for electrical performance, mechanical strength, fire resistance, and environmental compatibility. Compliance with both European (EN) and international (IEC) standards facilitates global acceptance and use across different mining jurisdictions.
Safety Thresholds and Operating Parameters
Electrical Safety Parameters
| Parameter | Value |
|---|---|
| Rated Voltage U0/U (Um) | 3.6/6 (7.2) kV |
| Test Voltage | 11 kV |
| Nominal Operating Voltage | 6000 V |
| Maximum Conductor Temperature (Continuous) | 90°C |
| Maximum Conductor Temperature (Short Circuit) | 250°C |
Environmental Operating Ranges
| Condition | Minimum Temperature | Maximum Temperature |
|---|---|---|
| Fixed Installation | -50°C | +80°C |
| Flexible Operation (Trailing) | -50°C | +60°C |
Mechanical Safety Thresholds
- Torsional Stress Resistance: ±100°/m – the cable can withstand significant twisting during operation
- Permanent Tensile Strength: 25 N/mm² – ensures the cable maintains integrity under pulling forces
- Minimum Bending Radius: According to VDE 0298-3:
- Fixed installation: 6 × D (cable diameter)
- Flexible operation: 10 × D
- Minimum distance with S-type directional changes: 20 × D
- UV Resistance: Yes – suitable for outdoor applications
- Oil Resistance: Yes – can withstand exposure to hydraulic fluids and lubricants
- Ozone Resistance: Yes – prevents degradation from atmospheric ozone and electrical discharges
Precautions for Use and Installation
Critical Installation Requirements
Warning: Improper installation or operation of high-voltage trailing cables can result in equipment damage, operational shutdowns, and serious safety hazards including electrocution and fire. Always follow manufacturer specifications and employ qualified personnel for installation and maintenance.
Installation Best Practices
- Bending Radius Compliance: Never exceed the minimum bending radius specifications. Operating inside the minimum design bending radius will damage internal cable structure and significantly reduce service life. For flexible trailing applications, maintain at least 10 times the cable diameter as the bending radius
- Cable Support Systems: Use appropriate cable towers, reelers, and support systems designed for the cable weight and operating conditions. Ensure support equipment is regularly inspected and maintained
- Route Planning: Design cable routes that minimize:
- Crossings by mobile equipment
- Exposure to falling rocks or material
- Sharp edges or abrasive surfaces
- Areas where water can accumulate
- Excessive strain from cable length or terrain
- Electroluminescent System Connection: The illuminating strings must be connected to an AC/AC inverter specifically designed for electroluminescent applications with:
- Maximum output voltage: 130V AC
- Output frequency: 800-1300 Hz
- Complete termination and installation sets are available from the manufacturer
- Termination and Jointing: Use only certified connectors and termination kits approved by the manufacturer. Ensure all connections are properly sealed against moisture ingress and mechanically secured
- Cable Protection: In areas where cable damage risk is high:
- Use cable protection pipes or covers at crossing points
- Install cable guards or barriers
- Mark cable locations with highly visible signage
- Construct adequately sized rock drains to prevent material accumulation on cables
- Handling During Movement: When relocating cables:
- Use appropriate cable tractors or reelers designed for the cable size
- Avoid excessive pulling force or towing excessive cable loops
- Ensure operators have clear visibility of cable position
- Check for debris or obstructions before moving
- Never allow equipment to drive over unsupported cable
Operational Precautions
- Regular Visual Inspection: Machine operators should conduct daily in-situ visual inspections for signs of damage, wear, or deterioration before beginning operations
- Weather Considerations: Pay special attention to cable condition and routing during:
- Heavy rainfall (water pooling near connectors)
- Extreme temperature fluctuations
- High winds affecting suspended cables
- Load Management: Ensure the cable is not subjected to:
- Excessive mechanical stress from equipment weight
- Crushing forces from mobile machinery
- Sharp impacts from falling materials
- Continuous abrasion against rough surfaces
- Connector Maintenance: Never leave plugs lying unsupported on the ground, especially in areas where water can accumulate. This can lead to moisture ingress and short circuits
Maintenance and Testing Requirements
- Establish and maintain regular testing schedules per manufacturer recommendations and local regulations
- Keep detailed records of all inspections, tests, and repairs
- Define and monitor cable life cycle criteria for each application
- Remove cables from service when they reach predetermined wear limits or show signs of significant damage
- Test insulation resistance regularly to detect early signs of deterioration
- Verify continuity of grounding conductors and shields
Common Problems and Solutions
1. Mechanical Damage from Mobile Equipment
Problem: Cable crushing, cutting, or impact damage from draglines, shovels, dozers, or other mobile equipment represents the most common cause of trailing cable failures in mining operations.
Causes:
- Poor visibility during night operations or in dark areas
- Operators not aware of cable position during equipment movement
- Equipment driving over unsupported cable sections
- Cable positioned too close to equipment travel paths
Solutions:
- Utilize the luminescent feature to maintain cable visibility at all times
- Implement strict cable route management protocols
- Train all equipment operators on cable awareness and safe operating procedures
- Install cable crossover structures at designated crossing points
- Use cable detection systems on mobile equipment
2. Damage from Falling Rocks or Materials
Problem: Rocks falling from dragline buckets, excavator buckets, or spoil dumps striking and damaging cables, potentially exposing conductors.
Causes:
- Cable routed too close to material handling areas
- Inadequate cable protection in rock drop zones
- Unstable spoil pile positioning
Solutions:
- Route cables away from areas where material spillage is likely
- Install protective covers or pipes in high-risk areas
- Implement strict material handling procedures near cables
- Regular monitoring of spoil pile stability
- Immediate cable inspection after any suspected impact
3. Water Ingress and Moisture Damage
Problem: Water entering cable connections or through damaged sheath can cause short circuits, insulation breakdown, and connector failures.
Causes:
- Connectors left lying in water-filled depressions
- Damaged plug seals
- Pin holes from sharp rocks allowing water ingress
- Inadequate cable drainage
Solutions:
- Always support connectors above ground level when not in use
- Regularly inspect and replace damaged connector seals
- Immediately repair any visible sheath damage
- Design cable routes with adequate drainage
- Use moisture-resistant connection systems
4. Cable Tractor and Handling Equipment Issues
Problem: Damage caused during cable relocation by tractors or handling equipment, including crushing, penetration, or excessive strain.
Causes:
- Improper positioning of cable in handling equipment
- Excessive clamping pressure
- Operator error or lack of visibility
- Pulling excessive cable length or loops
Solutions:
- Provide comprehensive training for cable handling equipment operators
- Use appropriate cable tractors designed for the cable size
- Install safety interlocks on clamping mechanisms
- Implement two-person verification procedures for cable positioning
- Regular maintenance and calibration of handling equipment
5. Excessive Bending or Flexing Damage
Problem: Cable failure due to operation below minimum bending radius or repeated sharp bends causing internal conductor or insulation damage.
Causes:
- Improper cable routing around obstacles
- Equipment positioned too close to cable connection points
- Lack of awareness of minimum bending radius requirements
Solutions:
- Calculate and mark minimum bending radius on site
- Use cable guides or pulleys at direction change points
- Provide adequate cable slack to prevent sharp bends
- Regular inspection for signs of over-bending (kinking or deformation)
- Training on proper cable handling techniques
6. Temperature-Related Issues
Problem: Cable performance degradation or damage in extreme temperature conditions.
Causes:
- Operating below -50°C or above +60°C in trailing applications
- Excessive heat buildup from overloading
- Thermal cycling causing material fatigue
Solutions:
- Monitor ambient and conductor temperatures regularly
- Ensure proper load management within cable rating
- Allow adequate cooling time between heavy load cycles
- Use temperature-appropriate cable selections for extreme environments
7. Electroluminescent System Failures
Problem: Loss of cable illumination reducing safety benefits.
Causes:
- Inverter malfunction or incorrect settings
- Damage to electroluminescent strings
- Poor electrical connections to lighting system
Solutions:
- Regular testing of illumination system functionality
- Use only approved inverters with correct voltage and frequency specifications
- Implement backup lighting plans when illumination fails
- Immediate investigation and repair of any lighting system issues
Conclusion
The TENAX-LUMEN (N)TSCGH3S 3,6/6KV Mining Trailing Cable represents a significant advancement in mining safety technology. By combining robust electrical and mechanical performance with innovative self-illuminating features, it addresses one of the industry’s most persistent challenges: cable visibility in dark or poorly lit environments.
With its extreme temperature capability (-50°C to +60°C), superior abrasion resistance, and compliance with international standards, this cable is engineered to withstand the harsh conditions typical of mining operations. The electroluminescent system provides 360-degree visibility even when the cable is not energized, dramatically reducing the risk of accidental damage from mobile equipment.
Successful implementation requires adherence to proper installation practices, regular maintenance, and comprehensive operator training. When installed and maintained according to manufacturer specifications, the TENAX-LUMEN cable significantly enhances operational safety, reduces downtime from cable damage, and contributes to more efficient mining operations.
For mining operations prioritizing safety, reliability, and operational efficiency, the TENAX-LUMEN trailing cable offers a proven solution backed by Prysmian Group’s decades of expertise in specialized cable manufacturing. Its unique combination of visibility, durability, and performance makes it an invaluable asset for modern mining operations worldwide.


