MULTINORM-CY H05VVC4V5-K HAR/UL/CSA: one screened, oil-resistant control cable for Europe and North America

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
MULTINORM-CY H05VVC4V5-K HAR/UL/CSA screened control cable | FeiChun Cable
FEICHUN CABLE · MULTI-APPROVED SCREENED CONTROL CABLE

MULTINORM-CY H05VVC4V5-K HAR/UL/CSA: one screened, oil-resistant control cable for Europe and North America

An engineering guide to the multi-approved control cable: HAR 300/500 V at 70 °C and UL/CSA 600 V at 90 °C, numbered black cores, a PVC inner sheath, a tinned copper braid of approx. 85 % coverage and a special oil-resistant grey PVC sheath for wet rooms and water-oil mixtures.

HAR · EN 50525-2-51UL Style 2517/2587CSA C22.2 No. 210.2300/500 V · 600 V70 °C · 90 °CVW-1 · FT1Cu braid ≈85 %UL 1581 T50.182 oilRoHS · CE
Document FC-ART-MNCY-2026-8C51Updated: 20 September 2026FeiChun Cable / 飞纯电缆
Engineer’s summary: MULTINORM-CY is the EMC-screened member of the multi-approved family: up to 2.5 mm² it carries HAR, UL and CSA; from 4 mm² it is the 2-NORM-CY UL/CSA version. Always apply the voltage and temperature rating of the code you design to.

1. Reading the designation

H05VVC4V5-K = harmonised 300/500 V, PVC insulation, PVC inner sheath, copper braid (C4), oil-resistant PVC sheath (V5), fine-wire conductor (K). MULTINORM-CY = HAR + UL + CSA (0.5–2.5 mm²). 2-NORM-CY (H)05VVC4V5-K = UL + CSA (4–120 mm²). ‘G’ = with GNYE; ‘x’ = without.

53

Standard constructions, 3 G 0.5 to 4 G 120 mm² (AWG 21 to 4/0).

3

Approvals: HAR, UL, CSA.

600 V

UL/CSA rating.

90 °C

UL/CSA temperature rating.

2. Construction

Cross-section MULTINORM-CY 7 G · HAR/UL/CSA, inner sheath, Cu braidEngineering-drawing style · functional, not to scale · final dimensions per approved order drawingGNYE123456Ø d = 8.3 … 56.6 mm (see tables) (see tables)1Bare Cu strand, IEC 60228 class 52PVC core insulation, black3White numerals (DIN VDE 0293)4GNYE protective conductor (G)5PVC inner sheath6Tinned Cu braid, approx. 85 %7Grey oil-resistant PVC sheath RAL 7001DocumentRevisionProjectionFC-ART-MNCY-2026-8C51A · 2026-091st angle
Figure 1: Construction of the 7 G version; callouts match the Pos. column of the materials table.
Materials table (Pos. = callout numbers in Figure 1)
Pos.ElementMaterial / formEngineering function
1ConductorBare Cu, fine-wire, IEC 60228 cl. 5Flexibility; AWG equivalents given for each size
2Core insulationPVC, blackHAR 70 °C; UL/CSA 90 °C rating
3Core markingWhite numerals per DIN VDE 0293Clear identification in multicore circuits
4Protective conductorGNYE core (‘G’)2-core ‘x’ versions without
5Inner sheathPVCAdditional mechanical protection; keeps braid round
6Overall screenTinned Cu braid, approx. 85 % optical coverageEMC-compliant screening
7Outer sheathSpecial oil-resistant PVC, grey RAL 7001EN 50363-4-1 and UL 1581 T50.182; VW-1, CSA FT1

3. Technical data

Technical data (complete)
ParameterValueEngineering note
Conductor materialBare copper strand
Conductor classIEC 60228 class 5
Core insulationPVC
Core identificationAcc. to DIN VDE 0293: black cores with white numerals; G = with GNYE
StrandingCores stranded in layers
Inner sheathPVCAdditional mechanical protection
Overall screenTinned copper braid, optical coverage approx. 85 %EMC-compliant
Outer sheathPVC (special oil-resistant compound)EN 50363-4-1 & UL 1581 T50.182
Sheath colourGrey, RAL 7001
Rated voltageHAR: U0/U 300/500 V; UL/CSA: 600 VUL/CSA 600 V allows parallel laying with other 600 V cables
Test voltage3 kV
Conductor resistanceAcc. to IEC 60228 cl. 5
Insulation resistanceMin. 20 MΩ × km
Current carrying capacityAcc. to DIN VDE (technical guideline)For NEC/NFPA 79 installations use the UL basis
Min. bending radius fixed6 × d
Min. bending radius moved12.5 × d
Operating temp. fixedHAR: −40 °C / +70 °C; UL/CSA: −40 °C / +90 °CRating depends on the approval applied
Operating temp. movedHAR: −5 °C / +70 °C; UL/CSA: −5 °C / +90 °C
Conductor temperature+70 °C operation; +150 °C short-circuitIEC/HAR basis
Burning behaviourSelf-extinguishing and flame-retardant acc. to IEC 60332-1; VW-1; CSA FT1
StandardEN 50525-2-51 / VDE 0285-525-2-51; UL Style 2517/2587; CSA C22.2 No. 210.2-M90 AWM I A/B II A/B
ApprovalsHAR: 300/500 V – 70 °C · UL/CSA: 600 V – 90 °CUp to 2.5 mm²: MULTINORM-CY H05VVC4V5-K HAR/UL/CSA; from 4 mm²: 2-NORM-CY (H)05VVC4V5-K UL/CSA
ComplianceRoHS; 2014/35/EU Low Voltage Directive (CE); LABS-/silicone-free during production

4. Dual ratings explained

Which rating applies
Design basisVoltageTemperatureFlame testSize range
IEC / EN (HAR)300/500 V70 °CIEC 60332-10.5–2.5 mm²
UL (AWM Style 2517/2587)600 V90 °CVW-10.5–120 mm²
CSA (C22.2 No. 210.2 AWM)600 V90 °CFT10.5–120 mm²

EMC and termination

1. Bond the braid 360° with EMC glands at both ends; avoid pigtails. 2. Use UL-listed EMC glands for North American panels. 3. Segregate screened control cables from unscreened power cables.

5. Full dimension and weight tables

All 53 constructions are listed, grouped by cross-section with AWG equivalents. Bending radii are calculated from the nominal outer diameter (6 × d fixed, 12.5 × d moved).

Cross-section 0.5 mm² / AWG 21 · MULTINORM-CY · HAR 300/500 V · UL/CSA 600 V · screened · 5 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
3 G 0.5 (AWG 21)MULTINORM-CY HAR/UL/CSA10035378.442.0105.050105
4 G 0.5 (AWG 21)MULTINORM-CY HAR/UL/CSA10035389.051.0123.054112
5 G 0.5 (AWG 21)MULTINORM-CY HAR/UL/CSA10000689.856.0147.059123
7 G 0.5 (AWG 21)MULTINORM-CY HAR/UL/CSA100004911.375.0195.068141
12 G 0.5 (AWG 21)MULTINORM-CY HAR/UL/CSA100353913.6124.0276.082170
Cross-section 0.75 mm² / AWG 19 · MULTINORM-CY · HAR 300/500 V · UL/CSA 600 V · screened · 9 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
2 x 0.75 (AWG 19)MULTINORM-CY HAR/UL/CSA10016068.341.0112.050104
3 G 0.75 (AWG 19)MULTINORM-CY HAR/UL/CSA10000398.850.0127.053110
4 G 0.75 (AWG 19)MULTINORM-CY HAR/UL/CSA10002329.661.0155.058120
5 G 0.75 (AWG 19)MULTINORM-CY HAR/UL/CSA100004510.469.0185.062130
7 G 0.75 (AWG 19)MULTINORM-CY HAR/UL/CSA100005012.293.0225.073152
12 G 0.75 (AWG 19)MULTINORM-CY HAR/UL/CSA100003614.3166.0354.086179
18 G 0.75 (AWG 19)MULTINORM-CY HAR/UL/CSA100282816.1257.0517.097201
25 G 0.75 (AWG 19)MULTINORM-CY HAR/UL/CSA100354619.6319.0678.0118245
34 G 0.75 (AWG 19)MULTINORM-CY HAR/UL/CSA100003822.6360.0805.0136282
Cross-section 1 mm² / AWG 18 · MULTINORM-CY · HAR 300/500 V · UL/CSA 600 V · screened · 9 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
2 x 1 (AWG 18)MULTINORM-CY HAR/UL/CSA10029048.548.0121.051106
3 G 1 (AWG 18)MULTINORM-CY HAR/UL/CSA10000409.561.0144.057119
4 G 1 (AWG 18)MULTINORM-CY HAR/UL/CSA100004210.176.0178.061126
5 G 1 (AWG 18)MULTINORM-CY HAR/UL/CSA100004611.085.0205.066138
7 G 1 (AWG 18)MULTINORM-CY HAR/UL/CSA100005113.1113.0263.079164
12 G 1 (AWG 18)MULTINORM-CY HAR/UL/CSA100003715.6195.0424.094195
18 G 1 (AWG 18)MULTINORM-CY HAR/UL/CSA100355018.0256.0560.0108225
25 G 1 (AWG 18)MULTINORM-CY HAR/UL/CSA100355121.2342.0760.0127265
34 G 1 (AWG 18)MULTINORM-CY HAR/UL/CSA100355223.8447.0945.0143298
Cross-section 1.5 mm² / AWG 16 · MULTINORM-CY · HAR 300/500 V · UL/CSA 600 V · screened · 8 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
2 x 1.5 (AWG 16)MULTINORM-CY HAR/UL/CSA10035579.469.0158.056118
3 G 1.5 (AWG 16)MULTINORM-CY HAR/UL/CSA100004110.480.0180.062130
4 G 1.5 (AWG 16)MULTINORM-CY HAR/UL/CSA100004311.194.0210.067139
5 G 1.5 (AWG 16)MULTINORM-CY HAR/UL/CSA100004712.3114.0240.074154
7 G 1.5 (AWG 16)MULTINORM-CY HAR/UL/CSA100005214.4143.0305.086180
12 G 1.5 (AWG 16)MULTINORM-CY HAR/UL/CSA100172117.4254.0482.0104217
18 G 1.5 (AWG 16)MULTINORM-CY HAR/UL/CSA100282920.1314.0611.0121251
25 G 1.5 (AWG 16)MULTINORM-CY HAR/UL/CSA100326624.3477.0950.0146304
Cross-section 2.5 mm² / AWG 14 · MULTINORM-CY · HAR 300/500 V · UL/CSA 600 V · screened · 6 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
3 G 2.5 (AWG 14)MULTINORM-CY HAR/UL/CSA100023012.3115.0244.074154
4 G 2.5 (AWG 14)MULTINORM-CY HAR/UL/CSA100004413.5141.0296.081169
5 G 2.5 (AWG 14)MULTINORM-CY HAR/UL/CSA100004814.8188.0367.089185
7 G 2.5 (AWG 14)MULTINORM-CY HAR/UL/CSA100160217.1241.0523.0103214
12 G 2.5 (AWG 14)MULTINORM-CY HAR/UL/CSA100356321.2397.0769.0127265
18 G 2.5 (AWG 14)MULTINORM-CY HAR/UL/CSA100263424.8556.01,080.0149310
Cross-section 4 mm² / AWG 12 · 2-NORM-CY · UL/CSA 600 V · screened · 4 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
3 G 4 (AWG 12)2-NORM-CY UL/CSA100358013.2208.0298.079165
4 G 4 (AWG 12)2-NORM-CY UL/CSA100159814.6236.0380.088182
5 G 4 (AWG 12)2-NORM-CY UL/CSA100358115.9277.0450.095199
7 G 4 (AWG 12)2-NORM-CY UL/CSA100358219.1395.0564.0115239
Cross-section 6 mm² / AWG 10 · 2-NORM-CY · UL/CSA 600 V · screened · 4 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
3 G 6 (AWG 10)2-NORM-CY UL/CSA100006915.3242.0398.092191
4 G 6 (AWG 10)2-NORM-CY UL/CSA100187416.7316.0485.0100209
5 G 6 (AWG 10)2-NORM-CY UL/CSA100182018.5413.0590.0111231
7 G 6 (AWG 10)2-NORM-CY UL/CSA100358321.2570.0745.0127265
Cross-section 10 mm² / AWG 8 · 2-NORM-CY · UL/CSA 600 V · screened · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
4 G 10 (AWG 8)2-NORM-CY UL/CSA100384021.3571.0760.0128266
Cross-section 16 mm² / AWG 6 · 2-NORM-CY · UL/CSA 600 V · screened · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
4 G 16 (AWG 6)2-NORM-CY UL/CSA100270524.8821.01,203.0149310
Cross-section 25 mm² / AWG 4 · 2-NORM-CY · UL/CSA 600 V · screened · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
4 G 25 (AWG 4)2-NORM-CY UL/CSA100358732.01,443.01,790.0192400
Cross-section 35 mm² / AWG 2 · 2-NORM-CY · UL/CSA 600 V · screened · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
4 G 35 (AWG 2)2-NORM-CY UL/CSA100240637.91,889.02,378.0227474
Cross-section 50 mm² / AWG 1 · 2-NORM-CY · UL/CSA 600 V · screened · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
4 G 50 (AWG 1)2-NORM-CY UL/CSA100358942.02,474.03,182.0252525
Cross-section 70 mm² / AWG 2/0 · 2-NORM-CY · UL/CSA 600 V · screened · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
4 G 70 (AWG 2/0)2-NORM-CY UL/CSA100359147.43,120.04,882.0284592
Cross-section 95 mm² / AWG 3/0 · 2-NORM-CY · UL/CSA 600 V · screened · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
4 G 95 (AWG 3/0)2-NORM-CY UL/CSA100359350.04,010.05,540.0300625
Cross-section 120 mm² / AWG 4/0 · 2-NORM-CY · UL/CSA 600 V · screened · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø mmCu index kg/kmWeight kg/kmMin. bend fixed 6 × d mmMin. bend moved 12.5 × d mm
4 G 120 (AWG 4/0)2-NORM-CY UL/CSA100359456.65,012.06,900.0340708

6. Application envelope

Power, control and connecting cable in electrical facilities, for fixed laying and occasional free movement without tensile stress and without forced guidance. Suitable for dry, humid and wet rooms, including water-oil mixtures. Outdoor use only with UV protection; not for burial.

Application envelope of MULTINORM-CY HAR/UL/CSA ✔ Drive to motor (VSD) 360° braid bonding at both ends ✔ Machine tools, coolant Free movement ≥ 12.5 × d, above −5 °C ✘ Not designed for • Drag chains / forced guidance• Tensile load, reels, festoons• Direct burial• Outdoors without UV protection• Pigtail braid terminations Use a PUR/TPE screened chain cablefor drag chains. Suitable for dry, humid and wet rooms. Suitable for dry, humid and wet rooms; the braid works only if terminated 360°.
Figure 2: Permitted duties and exclusions.

7. Comparison

MULTINORM compared with related cables
TypeApprovalsVoltageTemperatureFlameTypical use
MULTINORM H05VV5-FHAR + UL + CSA, unscreened300/500 V · 600 V70 / 90 °CIEC 60332-1, VW-1, FT1Unscreened control, EU + NA
H05VVC4V5-K HARHAR only, screened300/500 V70 °CIEC 60332-1EU screened control
MULTINORM-CY H05VVC4V5-KHAR + UL + CSA, screened300/500 V · 600 V70 °C HAR · 90 °C UL/CSAIEC 60332-1, VW-1, FT1Screened control for EU and North America
ÖPVC-JZ/OZ-Yö UL/CSAUL 2570 / CSA AWM450/750 V · 1 000 V80 °CIEC 60332-3-24 Cat. C, FT1Higher voltage, bunched fire rating
UL TC-ERUL tray cable600 V90 °CUL 1685 / FT4NEC field wiring

8. Design calculations

IEC installation: DIN VDE base rating × f(ambient) × f(grouping) × f(loaded cores), 70 °C basis North American machinery: NFPA 79 / UL ampacity tables, 90 °C cable rating (terminal ratings may limit to 60/75 °C) Short-circuit (PVC 70 → 150 °C, Cu): I_k ≈ 115 × S / √t e.g. 4 G 120, t = 0.5 s → ≈ 19.5 kA Voltage drop: ΔU = √3 × I × L × (R cosφ + X sinφ) Bending: fixed R ≥ 6 × d · moved R ≥ 12.5 × d e.g. 25 G 1.5 (d = 24.3 mm): 146 mm / 304 mm

9. Certification and traceability

This screened cable carries HAR (300/500 V, 70 °C) to EN 50525-2-51 / VDE 0285-525-2-51 up to 2.5 mm², and UL/CSA (600 V, 90 °C) to UL Style 2517/2587 and CSA C22.2 No. 210.2-M90 across the range. It is RoHS-conform, CE-conform to the 2014/35/EU Low Voltage Directive and LABS-/silicone-free during production. FeiChun Cable holds a complete export certification portfolio — including CE, UKCA, VDE, EAC, ATEX and IECEx — and every certificate supplied is checked against the exact type, voltage, factory and standard of the order.

Routine tests

Conductor resistance, 3 kV voltage test, braid continuity, insulation resistance, core numbering, dimensions and marking.

Type tests

IEC 60332-1, VW-1, CSA FT1; oil immersion to EN 50363-4-1 and UL 1581 T50.182.

Delivery documents

Approved datasheet, test report per drum, HAR/UL/CSA marking, batch number and length marking.

10. FAQ

What does MULTINORM-CY mean?

The screened (C = copper braid, Y = PVC) version of MULTINORM: one EMC control cable carrying HAR, UL and CSA approvals.

How should the braid be terminated?

360° with EMC glands at both ends for drive and switching noise; for North American panels use UL-listed EMC glands.

Why 2-NORM-CY from 4 mm²?

From 4 mm² the harmonised HAR scope ends; these sizes carry UL and CSA approvals and follow the H05VVC4V5-K construction, hence (H)05VVC4V5-K UL/CSA.

Why does the temperature differ?

HAR rates the cable at 70 °C, UL/CSA at 90 °C. Apply the rating of the code you are designing to.

What does parallel laying at 600 V mean?

In North American installations, cables may share a raceway only if their voltage ratings cover the highest voltage present. The 600 V rating allows it next to other 600 V cables.

What are VW-1 and FT1?

UL VW-1 and CSA FT1 are vertical flame tests on a single cable, the North American counterparts of IEC 60332-1.

Suitable for coolant?

Yes: wet rooms including water-oil mixtures, with an oil-resistant sheath to EN 50363-4-1 and UL 1581 T50.182.

FeiChun Cable / 飞纯电缆
Technical and project enquiries: [email protected]
Manufacturing in China, export support
+86 13855123218
FEICHUN CABLE

One screened control cable, three approvals: HAR, UL and CSA

For machine builders exporting to Europe and North America.

[email protected]

+86 13855123218

Document FC-ART-MNCY-2026-8C51. Final values are governed by the approved datasheet, order drawing, batch test reports and certificate scope.

Previous Article

MULTINORM H05VV5-F HAR/UL/CSA: one oil-resistant control cable for Europe and North America

Next Article

2-NORM 1 000 V UL/CSA: 90 °C control cable in grey and black +UV

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注