ÖPVC-JZ/OZ-Yö 1 000 V UL/CSA: one control cable for IEC and North American machines

An engineering guide to a dual-rated PVC control cable: UL 1 000 V and IEC 450/750 V, cURus 80 °C, increased mineral-oil resistance, a 6 kV test voltage and bunched-cable fire performance to IEC 60332-3-24 Cat. C and CSA FT1.

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
ÖPVC-JZ/OZ-Yö 1 000 V UL/CSA oil-resistant control cable | FeiChun Cable
FEICHUN CABLE · UL/CSA OIL-RESISTANT CONTROL CABLE

ÖPVC-JZ/OZ-Yö 1 000 V UL/CSA: one control cable for IEC and North American machines

An engineering guide to a dual-rated PVC control cable: UL 1 000 V and IEC 450/750 V, cURus 80 °C, increased mineral-oil resistance, a 6 kV test voltage and bunched-cable fire performance to IEC 60332-3-24 Cat. C and CSA FT1.

UL Style 2570CSA AWM I A/B II A/BcURus 80 °C · 1 000 VIEC 450/750 VIEC 60332-3-24 Cat. CCSA FT1CEI 20-22 IINBN C30-004 F26 kV testRoHS · CE
Document FC-ART-JZUL-2026-C267Updated: 20 September 2026FeiChun Cable / 飞纯电缆
Engineer’s summary: the value of this cable is dual compliance. A machine builder can wire one cabinet for both IEC and UL/CSA markets. Remember two limits: it is AWM (equipment wiring), not an NEC field-wiring tray cable, and it must not be flexed below −5 °C.

1. Reading the designation

JZ = with GNYE and numbered cores (‘G’); OZ = without GNYE (‘x’). Yö marks the oil-resistant PVC sheath (‘ö’ for Öl, oil). 1 000 V UL/CSA refers to the UL Style 2570 / CSA AWM rating; the same cable is rated 450/750 V under IEC.

101

Standard constructions, 2 × 0.5 to 4 G 70 mm².

6 kV

Test voltage.

1 000 V

cURus at 80 °C.

Cat. C

IEC 60332-3-24 bunched flame test.

2. Construction

The construction mirrors the standard JZ/OZ cable, but the sheath compound is the difference: it is formulated for increased mineral-oil resistance and for bunched-cable flame performance, and the insulation system is dimensioned for the UL 1 000 V rating and a 6 kV test.

Cross-section ÖPVC-JZ-Yö 7 G · numbered cores, oil-resistant FT1 sheathEngineering-drawing style · functional, not to scale · final dimensions per approved order drawingGNYE123456Ø d = 5.0 … 37.6 mm (see tables)1Bare Cu strand, IEC 60228 class 52PVC core insulation, black3White printed numerals (DIN VDE 0293)4GNYE protective conductor (JZ only)5Cores stranded in layers6Grey PVC sheath RAL 7001, mineral-oil resistant, flame-retardantDocumentRevisionProjectionFC-ART-JZUL-2026-C267A · 2026-091st angle
Figure 1: Construction of the 7 G version; callouts match the Pos. column of the materials table.
Materials table (Pos. = callout numbers in Figure 1)
Pos.ElementMaterial / formEngineering function
1ConductorBare Cu, fine-wire, IEC 60228 cl. 5Flexibility for installation and free movement
2Core insulationPVC, black (coloured to DIN VDE 0293-308 on request)UL 80 °C / 1 000 V rating; 6 kV test
3Core markingWhite numerals per DIN VDE 0293Unambiguous identification in multicore circuits
4Protective conductorGNYE core in JZ (‘G’) versionsOZ (‘x’) versions have none
5Core assemblyStranded in layersRound geometry for UL/CSA fittings and glands
6Outer sheathOil-resistant PVC ‘Yö’, grey RAL 7001Increased mineral-oil resistance; IEC 60332-3-24 Cat. C, CSA FT1

3. Technical data

Technical data (complete)
ParameterValueEngineering note
Conductor materialBare copper strand
Conductor classIEC 60228 class 5
Core insulationPVC
Core identificationAcc. to DIN VDE 0293: black cores with white numerals, with or without GNYEAlso available with coloured cores acc. to DIN VDE 0293-308, with or without GN/YE
StrandingCores stranded in layers
Outer sheathPVC (oil-resistant)
Sheath colourGrey, RAL 7001
Rated voltageUL: 1 000 V; IEC: 450/750 VOne cable, two rating systems
Test voltage6 kV
Conductor resistanceAcc. to IEC 60228 class 5
Insulation resistanceMin. 20 MΩ × km
Current carrying capacityAcc. to DIN VDEFor NEC installations apply the NEC/UL ampacity basis
Min. bending radius fixed4 × d
Min. bending radius moved15 × d
Operating temp. fixed−40 °C / +80 °C
Operating temp. moved−5 °C / +80 °CNote: higher lower limit than standard PVC types (−15 °C)
Burning behaviourSelf-extinguishing acc. to IEC 60332-1; reduced fire propagation and flame-retardant acc. to IEC 60332-3-24 (Cat. C), CEI 20-22 II (00), NBN C30-004 Cat. F2, CSA FT1Bunched-cable fire performance, not only single-cable
Chemical resistanceIncreased oil resistance; largely resistant to acids and bases
StandardUL Style 2570 / CSA AWM I A/B II A/B
ApprovalscURus: 80 °C – 1 000 V
ComplianceRoHS; 2014/35/EU Low Voltage Directive (CE); LABS-/silicone-free during production
Installation remarkWhere mechanical damage risk exists, protect with tubes, channels, etc.

4. Fire performance: what each test proves

Flame tests met by the cable
TestConfigurationWhat it demonstrates
IEC 60332-1Single vertical cable, 1 kW burnerSelf-extinguishing; flame does not travel along a single cable
IEC 60332-3-24 Cat. CBunched vertical cables, 1.5 l/m non-metallic volume, 20 minReduced fire propagation in cable trays and risers
CEI 20-22 IIItalian bunched-cable testAcceptance in Italian installations
NBN C30-004 Cat. F2Belgian flame-propagation categoryAcceptance in Belgian installations
CSA FT1Vertical flame test, CanadaCanadian flame rating for the AWM listing
IEC 60332-3-24 Cat. C is a propagation test, not fire resistance: the cable is not designed to keep circuits working during a fire. Where circuit integrity is required, specify a fire-resistant cable.

5. Full dimension and weight tables

All 101 constructions are listed, grouped by cross-section. Outer diameters are supplier values; bending radii are calculated from them.

Source data to verify before publication: two rows appear inconsistent in the supplied table and are shown as received — 26 G 1.5 (Cu index 619.0 = weight 619.0 kg/km; expected Cu index ≈ 374 kg/km) and 3 G 16 (weight 363.0 kg/km is below its Cu index 460.8 kg/km).
Cross-section 0.5 mm² · UL 1 000 V / IEC 450/750 V · 15 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
2 x 0.5OZ (without GNYE)10011715.09.634.02075
3 G 0.5JZ (with GNYE)10011725.314.441.02180
3 x 0.5OZ (without GNYE)10011735.314.441.02180
4 G 0.5JZ (with GNYE)10011745.719.249.02386
4 x 0.5OZ (without GNYE)10011765.719.249.02386
5 G 0.5JZ (with GNYE)10011776.324.064.02594
5 x 0.5OZ (without GNYE)10011816.324.064.02594
7 G 0.5JZ (with GNYE)10011886.833.678.027102
7 x 0.5OZ (without GNYE)10012006.833.678.027102
8 G 0.5JZ (with GNYE)10012018.138.4105.032122
9 G 0.5JZ (with GNYE)10012028.443.2116.034126
10 G 0.5JZ (with GNYE)10012038.448.0121.034126
12 G 0.5JZ (with GNYE)10012068.757.6139.035130
18 G 0.5JZ (with GNYE)100121010.486.4199.042156
25 G 0.5JZ (with GNYE)100121312.1120.0270.048182
Cross-section 0.75 mm² · UL 1 000 V / IEC 450/750 V · 10 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
2 x 0.75OZ (without GNYE)10012345.414.442.02281
3 G 0.75JZ (with GNYE)10012375.721.651.02386
4 G 0.75JZ (with GNYE)10012386.228.866.02593
5 G 0.75JZ (with GNYE)10012396.836.080.027102
7 G 0.75JZ (with GNYE)10012417.450.4104.030111
9 G 0.75JZ (with GNYE)10012439.264.8150.037138
12 G 0.75JZ (with GNYE)10012459.586.4177.038142
18 G 0.75JZ (with GNYE)100124811.4129.6262.046171
25 G 0.75JZ (with GNYE)100125413.3180.0356.053200
34 G 0.75JZ (with GNYE)100125515.7244.8495.063236
Cross-section 1 mm² · UL 1 000 V / IEC 450/750 V · 22 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
2 x 1OZ (without GNYE)10012645.719.249.02386
3 G 1JZ (with GNYE)10012666.128.864.02492
4 G 1JZ (with GNYE)10012706.638.479.02699
4 x 1OZ (without GNYE)10025796.638.479.02699
5 G 1JZ (with GNYE)10012717.248.095.029108
6 G 1JZ (with GNYE)10012737.857.6116.031117
7 G 1JZ (with GNYE)10012767.867.2123.031117
8 G 1JZ (with GNYE)10012799.576.8161.038142
9 G 1JZ (with GNYE)100128010.086.4179.040150
10 G 1JZ (with GNYE)100128210.096.0196.040150
12 G 1JZ (with GNYE)100128310.3115.2217.041154
14 G 1JZ (with GNYE)100128411.2134.4244.045168
16 G 1JZ (with GNYE)100128511.4153.6279.046171
18 G 1JZ (with GNYE)100128712.3172.8313.049184
19 G 1JZ (with GNYE)100128812.7182.4320.051190
20 G 1JZ (with GNYE)100215413.0192.0355.052195
25 G 1JZ (with GNYE)100129414.3240.0432.057214
26 G 1JZ (with GNYE)100215715.3249.6454.061230
34 G 1JZ (with GNYE)100129916.9326.4602.068253
37 G 1JZ (with GNYE)100130116.9355.2622.068253
42 G 1JZ (with GNYE)100130719.2403.2721.077288
50 G 1JZ (with GNYE)100130819.9480.0856.080298
Cross-section 1.5 mm² · UL 1 000 V / IEC 450/750 V · 17 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
2 x 1.5OZ (without GNYE)10013236.328.868.02594
3 G 1.5JZ (with GNYE)10013246.743.284.027100
4 G 1.5JZ (with GNYE)10013307.357.6108.029110
5 G 1.5JZ (with GNYE)10013338.072.0131.032120
6 G 1.5JZ (with GNYE)10013348.786.4160.035130
7 G 1.5JZ (with GNYE)10013448.7100.8171.035130
9 G 1.5JZ (with GNYE)100134611.2129.6245.045168
10 G 1.5JZ (with GNYE)100134711.2144.0269.045168
12 G 1.5JZ (with GNYE)100134811.5172.8298.046172
18 G 1.5JZ (with GNYE)100135414.4259.2433.058216
19 G 1.5JZ (with GNYE)100135614.4273.6443.058216
25 G 1.5JZ (with GNYE)100136016.0360.0594.064240
26 G 1.5JZ (with GNYE)100215817.2619.0619.069258
34 G 1.5JZ (with GNYE)100136319.2489.6827.077288
37 G 1.5JZ (with GNYE)100136419.2532.8858.077288
42 G 1.5JZ (with GNYE)100136521.6604.8989.086324
50 G 1.5JZ (with GNYE)100136623.0720.01,190.092345
Cross-section 2.5 mm² · UL 1 000 V / IEC 450/750 V · 13 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
2 x 2.5OZ (without GNYE)10013867.548.0105.030112
3 G 2.5JZ (with GNYE)10013898.072.0132.032120
4 G 2.5JZ (with GNYE)10013928.796.0167.035130
5 G 2.5JZ (with GNYE)10013959.6120.0205.038144
7 G 2.5JZ (with GNYE)100139710.7168.0268.043160
8 G 2.5JZ (with GNYE)100139813.3192.0348.053200
10 G 2.5JZ (with GNYE)100139914.3240.0416.057214
12 G 2.5JZ (with GNYE)100140014.4288.0475.058216
14 G 2.5JZ (with GNYE)100140115.7336.0535.063236
16 G 2.5JZ (with GNYE)100140216.7384.0608.067250
18 G 2.5JZ (with GNYE)100140617.1432.0692.068256
25 G 2.5JZ (with GNYE)100140719.9600.0952.080298
34 G 2.5JZ (with GNYE)100140824.9816.01,325.0100374
Cross-section 4 mm² · UL 1 000 V / IEC 450/750 V · 4 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
3 G 4JZ (with GNYE)10014139.3115.2194.037140
4 G 4JZ (with GNYE)100141410.5153.6251.042158
5 G 4JZ (with GNYE)100141611.5192.0312.046172
7 G 4JZ (with GNYE)100141912.8268.8407.051192
Cross-section 6 mm² · UL 1 000 V / IEC 450/750 V · 4 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
3 G 6JZ (with GNYE)100142311.1172.8281.044166
4 G 6JZ (with GNYE)100142412.4230.4360.050186
5 G 6JZ (with GNYE)100142513.7288.0450.055206
7 G 6JZ (with GNYE)100142715.3403.2591.061230
Cross-section 10 mm² · UL 1 000 V / IEC 450/750 V · 4 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
3 G 10JZ (with GNYE)100142814.5288.0463.058218
4 G 10JZ (with GNYE)100142915.9384.0591.064238
5 G 10JZ (with GNYE)100143117.9480.0738.072268
7 G 10JZ (with GNYE)100143219.8672.0958.079297
Cross-section 16 mm² · UL 1 000 V / IEC 450/750 V · 4 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
3 G 16JZ (with GNYE)100143716.8460.8363.067252
4 G 16JZ (with GNYE)100143818.7614.4864.075280
5 G 16JZ (with GNYE)100143921.4768.01,089.086321
7 G 16JZ (with GNYE)100144023.61,075.21,439.094354
Cross-section 25 mm² · UL 1 000 V / IEC 450/750 V · 3 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
4 G 25JZ (with GNYE)100144223.8960.01,359.095357
5 G 25JZ (with GNYE)100144426.41,200.01,705.0106396
7 G 25JZ (with GNYE)100144529.51,680.02,246.0118442
Cross-section 35 mm² · UL 1 000 V / IEC 450/750 V · 2 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
4 G 35JZ (with GNYE)100144926.71,344.01,826.0107400
5 G 35JZ (with GNYE)100145130.61,680.02,291.0122459
Cross-section 50 mm² · UL 1 000 V / IEC 450/750 V · 2 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
3 G 50JZ (with GNYE)100145829.61,440.02,181.0118444
4 G 50JZ (with GNYE)100145932.61,920.02,767.0130489
Cross-section 70 mm² · UL 1 000 V / IEC 450/750 V · 1 constructions
Dimension n × mm²VersionReference item no.Outer Ø (supp.) mmCu index kg/kmWeight kg/kmMin. bend radius fixed (4 × d) mmMin. bend radius moved (15 × d) mm
4 G 70JZ (with GNYE)100146037.62,688.03,733.0150564

6. Application envelope

Power, control and connecting cable in electrical facilities where increased mineral-oil resistance is required. For fixed laying and flexible applications with free movement, without tensile stress and without forced guidance. Suitable for dry, humid and wet rooms. Outdoor use only with UV protection; not for burial. Where mechanical damage risk exists, install in tubes, channels or similar.

Application envelope of ÖPVC-JZ/OZ ✔ Control cabinets and panels UL/CSA panels for North American export ✔ Machine tools, oil mist, trays Fixed laying; occasional free movement ≥ 15 × d ✘ Not designed for • Drag chains / forced guidance• Tensile load, reels, festoons• Direct burial• Outdoors without UV protection• Exposed routes without tube/channel Where damage risk exists, install in tubes or channels;for chains use a PUR/TPE chain cable. Suitable for dry, humid and wet rooms. Increased mineral-oil resistance plus IEC 60332-3-24 Cat. C for bunched runs.
Figure 2: Permitted duties and exclusions.

7. Comparison

JZ/OZ-Yö UL/CSA compared with related cables
TypeVoltageTest voltageFireOilTypical use
ÖPVC-JZ/OZ (standard)300/500 V4 kVIEC 60332-1TM54 oil resistanceIEC markets, general wiring
ÖPVC-JZ/OZ-Yö UL/CSAUL 1 000 V · IEC 450/750 V6 kVIEC 60332-3-24 Cat. C, CSA FT1Increased mineral-oil resistanceMachines exported to North America and Europe
ÖPVC-JB/OB-YCY300/500 V · 0.6/1 kV4 kVIEC 60332-1Largely oil-resistantEMC-screened circuits
UL TC-ER (tray cable)600 V—UL 1685 / FT4Per jacketUS tray installations, exposed runs

8. Design calculations

IEC installation: DIN VDE base rating × f(ambient) × f(grouping) × f(loaded cores) UL/NEC equipment: use the ampacity basis of the applicable product standard (e.g. NFPA 79 for industrial machinery) Short-circuit (PVC, Cu): I_k ≈ 115 × S / √t e.g. 4 G 70, t = 0.5 s → ≈ 11.4 kA Voltage drop: ΔU = √3 × I × L × (R cosφ + X sinφ) Bending: fixed R ≥ 4 × d · moved R ≥ 15 × d e.g. 50 G 1.5 (d = 23.0 mm): 92 mm / 345 mm Moved below −5 °C: not permitted

9. Certification and traceability

This cable carries cURus recognition (80 °C, 1 000 V) under UL Style 2570 and CSA AWM I A/B II A/B, meets IEC 60332-3-24 Cat. C, CEI 20-22 II, NBN C30-004 F2 and CSA FT1, and is RoHS-conform, CE-conform to 2014/35/EU and LABS-/silicone-free during production. FeiChun Cable backs this with a complete export certification portfolio — including CE, UKCA, VDE, EAC, ATEX and IECEx — and every certificate supplied is checked against the exact type, voltage, factory and standard of the order.

Routine tests

Conductor resistance, 6 kV voltage test, insulation resistance, core numbering, dimensions and marking.

Type tests

Bunched flame (IEC 60332-3-24 Cat. C), CSA FT1, mineral-oil immersion, sheath ageing.

Delivery documents

Approved datasheet, test report per drum, UL/CSA marking, batch number and length marking.

10. FAQ

Why two voltage ratings?

UL/CSA AWM Style 2570 rates the cable at 1 000 V; under IEC it is rated 450/750 V. One cable can therefore be used in a machine shipped to either market.

What does cURus mean?

UL Recognized Component marking valid for both the US and Canada, here for 80 °C and 1 000 V as appliance wiring material (AWM).

Is AWM the same as a field-wiring tray cable?

No. AWM is for wiring within equipment and machines. Field wiring in buildings under the NEC normally requires listed types such as TC-ER. Check the installation code.

What is IEC 60332-3-24 Cat. C?

A bunched-cable vertical flame test: a defined non-metallic volume of cables must not propagate flame beyond a set height. It is stricter than the single-cable IEC 60332-1 test.

Why −5 °C when moved?

The oil-resistant sheath compound is optimised for oil resistance and fire behaviour; below −5 °C, avoid flexing. Fixed installation remains possible down to −40 °C.

How many cores?

From 2 to 50 cores in 0.5–1.5 mm², up to 34 cores in 2.5 mm², and up to 7 cores to 70 mm².

FeiChun Cable / 飞纯电缆
Technical and project enquiries: [email protected]
Manufacturing in China, export support
+86 13855123218
FEICHUN CABLE

One oil-resistant control cable for IEC and UL/CSA machines

For machine tools, control panels and export equipment.

[email protected]

+86 13855123218

Document FC-ART-JZUL-2026-C267. Final values are governed by the approved datasheet, order drawing, batch test reports and certificate scope.

Previous Article

ÖPVC-JZ/OZ: numbered-core PVC power, control and connecting cable, 2–65 cores

Next Article

ÖPVC-JZ/OZ ARCTIC +UV: −60 °C fixed, flexible down to −40 °C, black UV sheath

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注