Comprehensive Technical Guide to Mining Cables for Surface, Underground, and Tunneling Operations

Complete List of Mining Cable Models and Applications
Comprehensive Technical Guide to Mining Cables for Surface, Underground, and Tunneling Operations
About Anhui Feichun Special Cable Co., Ltd.
Anhui Feichun Special Cable Co., Ltd. is a premier manufacturer of specialized mining cables, offering a comprehensive range of products compliant with international standards including DIN VDE 0250, BS 6708, AS/NZS 1802, MT818, IEC, and CSA. Our mining cables are engineered for the most demanding applications in open-cast mining, underground mining, tunneling, and industrial operations worldwide.
Quick Navigation
1. Introduction & Overview
Mining operations require specialized electrical cables that can withstand extreme environmental conditions, mechanical stresses, and safety requirements unique to the mining industry. This comprehensive guide catalogs all major mining cable models available for various applications, from surface excavation to deep underground operations.
What This Guide Covers:
- Complete Cable Model Catalog: Detailed specifications for PROTOLON, PROTOMONT, TENAX, FELTOFLEX, TROMMELFLEX, ANACONDA, BOSTMINE, and more
- Application-Specific Recommendations: Cables optimized for reeling, trailing, dredging, shearer chains, festoon systems, and fixed installations
- International Standards Compliance: Coverage of DIN VDE 0250, BS 6708, AS/NZS 1802/2802, MT818, IEC, UL, CSA, and regional standards
- Technical Specifications: Voltage ratings, insulation types, sheath materials, temperature ranges, and mechanical properties
- Safety Guidelines: Installation procedures, precautions, and troubleshooting for safe mining operations
Purpose of Mining Cables
Mining cables serve critical functions in modern mining operations:
- Power Transmission: Delivering electrical power from substations to mobile and fixed mining equipment
- Control & Signaling: Enabling remote operation and monitoring of mining machinery
- Data Communication: Facilitating real-time data transmission through integrated fiber optics
- Safety Systems: Supporting critical safety and emergency communication systems
Key Characteristics Required
2. Major Product Families
Manufacturer: Prysmian Group
Standards: DIN VDE 0250-813/812, BS 6708, AS/NZS 1802/2802, IS 14494
Applications: Reeling and trailing cables for open-cast mining, medium to high voltage power transmission
PROTOLON Models:
- PROTOLON (M)-R: MV reeling cable (6-35 kV) with HEPR insulation, high-grade CR sheath
- PROTOLON (SB): MV trailing cable (6-20 kV) for excavators, EPR insulation
- PROTOLON (ST): MV cable for underwater use (6-35 kV), dredging applications
- PROTOLON (M)-F: MV semi-flexible cable (3-30 kV) for fixed installations with fiber optics option
- PROTOLON SB IQ: Intelligent cable with integrated monitoring systems
Manufacturer: Prysmian Group
Standards: Based on DIN VDE 0250-813/812, BS 6708, AS/NZS 1802/2802
Applications: Underground mining, coal cutters, shearer chains, trailing operations
PROTOMONT Models:
- PROTOMONT (V): Coal shearer cable for chain operation (LV 1 kV, MV 3-6 kV), EPR/CM
- PROTOMONT (Z): Coal cutter cable (LV 1 kV), EPR insulation, CM sheath
- PROTOMONT (MT): Semi-flexible cable (1 kV) with optimized dimensions for conveyor belts
- PROTOMONT MSR: Data, signal, and control cables (250 V), PE insulation, CR sheath
- PROTOMONT TBM: Tunnel boring machine cable (MV 6-35 kV), HEPR/chloroprene
Manufacturer: Prysmian Group
Standards: DIN VDE 0250-813/812, CZ, EPN78
Applications: Underground mining, reeling drums, trailing, festoon systems
TENAX Models:
- TENAX CTE: Coal cutter cable (LV 1 kV), EPR/CM for shearer chain applications
- TENAX SAS: Medium voltage cable (6-20 kV), EPR/Rubber or PUR sheath
- TENAX LUMEN: Enhanced visibility cable (MV 6-20 kV) with high-visibility sheath
- TENAX HTT: High-temperature tunnel cable (MV 6-35 kV), HEPR/chloroprene
- TENAX-LWL: Fiber optic cable for optical data transmission in mining
Manufacturer: Prysmian Group
Standards: DIN VDE 0250-813/812
Applications: Single-core MV cables, switch-gear connections, mobile transformers
FELTOFLEX Models:
- FELTOFLEX NTMCWOEU: MV single-core cable with cold-removable semi-conductive layer
- FELTOFLEX (Standard): Highly flexible connection for substations, generators (3-35 kV)
- FELTOFLEX HV: High voltage cables (66-155 kV) for extreme flexibility applications
Manufacturer: Prysmian Group
Standards: Based on DIN VDE 0250-813/812
Applications: Reeling drums, hoisting equipment, conveyor systems
TROMMELFLEX Models:
- TROMMELFLEX M-PUR: LV 1 kV reeling cable with polyurethane sheath
- TROMMELFLEX PUR-HF: Halogen-free PUR cable for heavy-duty reeling applications
- TROMMELFLEX (Standard): EPR insulation, CM sheath for underground reeling
Manufacturer: Prysmian Group
Standards: Based on DIN VDE 0250, BS 6708, AS/NZS 1802/2802
Applications: Fiber optic communication cables for mining installations
OPTOFLEX Models:
- OPTOFLEX (M): Rubber-sheathed flexible fiber optic cable, suitable for underground
- OPTOFLEX (M) FO: Fiber optic cable with multiple fiber types (G50/125, G62.5/125, E9/125)
Manufacturer: Prysmian Group
Standards: Based on DIN VDE 0250-813/812, BS 6708, AS/NZS 1802/2802
Applications: Medium voltage flexible power cables, fixed and semi-fixed installations
SUPROMONT Models:
- SUPROMONT: MV flexible cable (6-35 kV), HEPR insulation, PVC/Compound/LSOH sheath
- SUPROMONT (Fixed): For semi-fixed installations in underground mines
Manufacturer: Prysmian Group
Standards: Based on DIN VDE 0250-813/812, BS 6708, AS/NZS 1802/2802
Applications: Low voltage flexible cables for scoops and jumbo drills
CORDAFLEX Models:
- CORDAFLEX (S): LV 1 kV cable, EPR/CM for trailing operations
- PROTOMONT (S): Similar specification for shearer chain applications
Manufacturer: Various (North American manufacturers)
Standards: ICEA, UL, CSA
Applications: North American mining operations, surface and underground
ANACONDA Models:
- Anaconda Types W, G, G-GC: 2 kV to 35 kV SHD-GC portable power cables
- Anaconda Type SHD-GC: Shielded cables (5-35 kV) for medium voltage applications
- Anaconda Type MP-GC: Mining power cables (5-35 kV) with ground check conductors
- Snake Stripe: High-visibility mining cables with distinctive stripe patterns
Manufacturer: Various
Standards: CSA
Applications: Canadian mining operations, trailing and reeling applications
BOSTMINE Models:
- Bostmine Types W, G, G-GC: 2 kV to 35 kV SHD-GC cables
- Bostmine Type SHD-GC: 2 kV to 35 kV shielded trailing cables
- Bostmine Type MP-GC: 5-35 kV mining power cables
Manufacturer: Various (Australian/Asian manufacturers)
Standards: ICEA S-75-381, IEC 60502-1, Based on VDE 0250 and BS6708
Applications: International mining operations
Mineflex Models:
- Mineflex: Based on VDE 250 parts, IEC 60502-1, ICEA S-93-639
- Mineflex TPU 0.6/1kV: EPR insulation, TPU outer sheath
- EATFEVA RZT 0.6/1kV: Excellent tear and notch resistance
Manufacturer: Various
Standards: AS/NZS 1802/2802
Applications: Australian and New Zealand mining operations
MINEMASTER Models:
- TXA9 3.3/11kV: EPR insulation, PCP sheath, reeling applications
- TXA9 11/22kV: EPR insulation for coal/metalliferous mines
- TX55 3.3/11kV: Superflex EPR insulation, PCP sheath
- TX75 11kV: EPR insulation for reeling applications
- TXA1 1.1/1.1kV: EPR insulation, PCP sheath, superflex trailing
- TXA1 and TXA1 superflex: 1.1/1.1kV for festoon, shearer, and reeling
Manufacturer: Various (Asian manufacturers)
Standards: MT818, VDE 0250 (LV, MV), ICEA S-75-381 (MV)
Applications: Chinese and international mining operations
TEMK Models:
- TEMK TUNC: Low voltage cable for underground mining
- TEHF FLEX: High flexibility trailing cable
- TEMK TD/HDGC3-C: MV cable, EPR/CPE/TPU sheath
- MSPB: 0.6/1 kV (N)SHTOEU-J, EPR/CPE/TPU construction
- MY/MYP/MYPT: Chinese standard mining cables (0.66/1.14kV, 1.9/3.3kV)
Manufacturer: Prysmian Group
Standards: IEC 60502-1 (LV), VDE 0250 (LV, MV), ICEA S-75-381, AS/NZS 2802 (MV)
Applications: Tunneling operations, underground mining
TUNNELFLEX Models:
- TUNNELFLEX: MV 6-20 kV, HEPR insulation, high-grade chloroprene sheath
- PANZERFLEX: Armored version for enhanced mechanical protection
- TUNNELFLEX TK: 1 kV HEPR insulation for tunnel boring machines
Manufacturer: Various (European manufacturers)
Standards: UNE 22511, UNE 22520, UNE 22515-1/2, UNE 22561
Applications: European (Spanish) mining operations
Models:
- EPIRONED MINAS: 1 kV-6 kV EPR insulation, HEPR outer sheath, PVC compound
- SINTERAX MINAS: 0 kV EPR insulation, PVC outer sheath
- TELEFONED E SINTERAX: Control and signaling cables
- TELEFONED LV 500V: PE insulation, PVC outer sheath
- SINTERAX LV: 0 kV EPR insulation, PVC compound sheath
3. Surface/Opencast Mining Cables
Surface mining operations require cables that can withstand harsh outdoor environments, including extreme temperatures, UV exposure, moisture, and mechanical abuse from heavy equipment.
3.1 Reeling Applications
Recommended Cables:
- PROTOLON (M)-R (MV 6-35 kV)
- TENAX SAS (MV 6-20 kV)
- TROMMELFLEX M-PUR (LV)
- ANACONDA Type W, G (2-35 kV)
Recommended Cables:
- PROTOLON (M)-R IQ (with monitoring)
- FELTOFLEX (MV single-core)
- MINEMASTER TXA9 (AS/NZS)
Recommended Cables:
- PROTOLON (M)-R with fiber optics
- TENAX LUMEN (high visibility)
- TROMMELFLEX PUR-HF
3.2 Trailing Applications
| Equipment Type | Cable Model | Voltage Rating | Key Features |
|---|---|---|---|
| Electric Shovels | PROTOLON (SB) | MV 6-20 kV | EPR insulation, CR sheath, high flexibility |
| Hydraulic Excavators | TENAX SAS / ANACONDA SHD-GC | 2-35 kV | Rubber/PUR sheath, extreme mechanical resistance |
| Crushers | PROTOMONT (MT) | LV 1 kV | Semi-flexible, optimized dimensions |
| Mobile Drills | CORDAFLEX (S) | LV 1 kV | EPR/CM, compact design |
| Coal Cutters | BOSTMINE W/G Type | 2-35 kV | CSA certified, shielded construction |
3.3 Dredging Applications
Recommended Cables:
- PROTOLON (ST) – MV 6-35 kV
- Insulation: HEPR
- Sheath: CM (water resistant)
- Special feature: Continuous underwater operation
Recommended Cables:
- TMP-NSSHOEU (LV)
- TMP-NTSWOEU (MV 1.8/3, 3.6/6 kV)
- Water immersion depth: up to 1000m
3.4 Semi-Flexible Applications
For equipment requiring limited movement or periodic repositioning:
- PROTOLON (M)-F: MV 3-30 kV, for conveyors and shiftable units
- PROTOMONT (MT): LV 1 kV, optimized for conveyor belt installations
- SUPROMONT: MV 6-35 kV, for semi-fixed installations
3.5 Single Core Applications
Medium to high voltage single-core cables for specialized installations:
- FELTOFLEX NTMCWOEU: MV 6-35 kV, switch-gear connections, mobile transformers
- PROTOLON (M) Single Core: MV 6-35 kV, optimized dimensions
- FELTOFLEX HV: 66-155 kV, extreme flexibility for constrained spaces
3.6 Control & Signaling
Low voltage cables for control circuits and data transmission:
- PROTOMONT MSR: 250 V, PE insulation, CR sheath
- OPTOFLEX (M): Fiber optic cables for data communication
- TEMK Control Cables: Multi-core control and signaling
4. Underground Mining Cables
Underground mining presents unique challenges including explosive atmospheres (methane, coal dust), confined spaces, high humidity, and stringent safety requirements. All cables must be flame-retardant and often require metallic screening for electrical safety.
4.1 Shearer Chain Applications
- Insulation: EPR (Ethylene Propylene Rubber)
- Outer Sheath: CM (Chloroprene/Chlorosulfonated Polyethylene)
- Construction: Double concentric control/PE conductors
- Temperature Range: -20°C to +60°C (flexible operation)
- Special Features: Ultra-high flexibility, torsion resistant, MSHA approved
- Insulation: EPR Type 3GI3
- Outer Sheath: CM compound
- Applications: Continuous miners, roadheaders
Similar specifications to PROTOMONT (V) for shearer chain applications, EPR insulation with CM sheath.
4.2 Trailing Applications (Underground)
Flexible cables for mobile equipment in underground mines:
| Cable Model | Voltage | Application | Standards |
|---|---|---|---|
| CORDAFLEX (S) / PROTOMONT (S) | LV 1 kV | Shuttle cars, LHD vehicles, utility vehicles | DIN VDE 0250-813 |
| TENAX (Standard) | LV 1 kV | Underground mobile equipment | DIN VDE 0250-813 |
| ANACONDA W, G, G-GC | 2-35 kV | High voltage trailing applications | ICEA, UL, CSA |
| MINEMASTER TXA1 | 1.1/1.1 kV | Superflex trailing for coal/metalliferous | AS/NZS 1802 |
| TEMK TD/HDGC3-C | 1.9/3.3 kV | Chinese standard underground trailing | MT818 |
4.3 Reeling Applications (Underground)
Recommended Cables:
- TROMMELFLEX M-PUR (LV 1 kV)
- TENAX LK (reeling drum variant)
- Mineflex TPU 0.6/1kV
- MINEMASTER TX75 11kV (reeling)
Recommended Cables:
- TENAX-LWL (Fiber optic)
- OPTOFLEX (M) (Underground rated)
- TELEFONED (Control cables)
4.4 Festoon Systems
- PROTOMONT: 1kV and 6kV variants, EPR/CM construction
- TUNNELFLEX: MV 6-20 kV, HEPR/chloroprene for tunnel festoons
- MINEMASTER TXA1 Superflex: Designed for festoon applications (AS/NZS)
- MY/MYP/MYPT: Chinese standard festoon cables
4.5 Control & Signaling (Underground)
| Cable Type | Voltage | Application |
|---|---|---|
| PROTOMONT MSR | 250 V | Data, signal, and control circuits, PE insulation |
| OPTOFLEX (M) | N/A | Fiber optic communication, underground monitoring |
| TELEFONED E SINTERAX | 500V | Spanish standard control and signaling |
| SINTERAX LV | 0 kV | Low voltage control circuits |
4.6 Fixed Installation (Underground)
Cables for permanent or semi-permanent underground power distribution:
4.7 Semi-Fixed Installation (Underground)
- PROTOMONT (Semi-Fixed): 1 kV EPR/CM or 6-35 kV HEPR/PVC
- SUPROMONT: MV 6-35 kV for semi-fixed power distribution
- TUNNELFLEX TK: 1 kV HEPR for tunnel installations
5. Specialized Applications
5.1 Tunneling Operations
Tunnel Boring Machines (TBM)
- PROTOMONT TBM: MV 6-35 kV, HEPR/high-grade chloroprene or LSOH
- TUNNELFLEX: MV 6-20 kV, HEPR/chloroprene compound
- TENAX HTT: MV 6-35 kV, high-temperature tunnel cable
- ANACONDA Types W, G: 2-35 kV for tunnel construction
- Enhanced fire performance (LSOH options preferred)
- Resistance to water, concrete additives, and chemicals
- High mechanical strength for trailing through rough terrain
- Extended lengths to minimize joints (up to several kilometers)
5.2 Underwater/Submersible Applications
| Cable Model | Max Depth | Application |
|---|---|---|
| PROTOLON (ST) | Continuous underwater | Dredging operations, underwater excavation |
| TMP-NSSHOEU | Up to 1000m | Deep submersible pumps |
| TMP-NTSWOEU | Up to 1000m | MV submersible applications (1.8/3, 3.6/6 kV) |
| TROMMELFLEX PUR-HF | 50m | Wet environments, temporary water immersion |
5.3 Fiber Optic Integration
Modern mining operations increasingly require integrated power and data transmission:
- Fiber Types Available: G50/125, G62.5/125, E9/125
- Fiber Count: 4-24 fibers (customizable)
- Application: Real-time monitoring, automation control, SCADA systems
- Benefits: Single cable solution for power + communication
Dedicated fiber optic cable for mining installations, rubber sheath, suitable for underground use. Available in G50/125, G62.5/125, E9/125 fiber specifications.
Rubber-sheathed fiber optic cable specifically designed for mining data transmission networks.
5.4 High Visibility Cables
MV 6-20 kV with high-visibility colored PUR sheath. Ideal for safety-critical applications where cable location must be easily identified. Applications include:
- Surface mining in low-light conditions
- Underground installations requiring easy identification
- Emergency evacuation route marking
- Safety zone delineation
5.5 Extreme Temperature Applications
| Temperature Range | Recommended Cable | Special Features |
|---|---|---|
| Very Cold (-45°C) | PROTOMONT EMV-FC (-45°C) | Cold-resistant LSOH sheath, screened for VFD |
| High Temperature | TENAX HTT | High-temperature tunnel cable, enhanced thermal rating |
| Wide Range (-40°C to +80°C) | PROTOLON (M)-R | Fixed installation capability across extreme ranges |
5.6 EMC Compliant Cables (VFD Applications)
For Variable Frequency Drive (VFD) applications requiring electromagnetic compatibility:
- PROTOMONT EMV-FC (N)SSHCOEU: LV screened cable, EMC compliant for VFD
- PROTOMONT EMV-FC (-45°C): Cold-resistant variant
- Special features: Copper screening, low impedance, reduced EMI emissions
6. Standards & Compliance
6.1 International Standards Coverage
| Standard | Region | Cable Families Covered | Key Requirements |
|---|---|---|---|
| DIN VDE 0250 | Germany/Europe | PROTOLON, PROTOMONT, TENAX, FELTOFLEX, TROMMELFLEX | Parts 812, 813, 814 – Flexible cables for power installations |
| BS 6708 | UK/Commonwealth | PROTOLON, PROTOMONT equivalents | Flexible cables for mines and quarries, various types |
| AS/NZS 1802/2802 | Australia/NZ | MINEMASTER, PROTOLON, PROTOMONT | Elastomeric cables for mines and quarries |
| MT818 | China | TEMK, MY/MYP/MYPT series | Rubber-sheathed flexible cables for coal mines |
| ICEA/UL/CSA | North America | ANACONDA, BOSTMINE, SNAKE STRIPE, CAROL | Portable power cables for mining applications |
| IS 14494 | India | PROTOLON, PROTOMONT equivalents | Flexible cables for mining applications |
| UNE 22511/22520 | Spain/Europe | EPIRONED, SINTERAX, TELEFONED | Cables for underground mining installations |
| IEC 60502-1 | International | TUNNELFLEX, PANZERFLEX, Mineflex | Power cables with extruded insulation |
6.2 Mining Authority Approvals
- Regulatory violations and mine closure orders
- Safety hazards and increased accident risk
- Voided insurance coverage
- Legal liability for operators and suppliers
6.3 Fire Performance Standards
| Test Standard | Requirement | Cable Types |
|---|---|---|
| DIN EN 60332-1-2 / IEC 60332-1-2 | Single vertical wire flame test | All mining cables |
| VDE 0482-332-1-2 | Flame retardance, halogen-free options | TROMMELFLEX PUR-HF, LSOH variants |
| BS 6708 Fire Tests | Specific flame retardance requirements | BS 6708 compliant cables |
| AS/NZS Standards | Australian fire performance | MINEMASTER series |
7. Technical Specifications Summary
7.1 Voltage Ratings Overview
| Voltage Class | Typical Ratings (U0/U) | Applications | Cable Examples |
|---|---|---|---|
| Extra Low Voltage | 250V, 320/550V | Control, signaling, pilot circuits | PROTOMONT MSR, BS 6708 Types 506-524 |
| Low Voltage | 0.6/1 kV, 640/1100V, 1.1/1.1 kV | Mobile equipment, general power distribution | PROTOMONT (V/Z/S), CORDAFLEX, MINEMASTER TXA1 |
| Medium Voltage | 1.9/3.3 kV, 3.6/6 kV, 6.6/11 kV | Large excavators, high-power equipment | PROTOLON (M)-R, TENAX SAS, ANACONDA SHD-GC |
| High Voltage | 20/35 kV, 66-155 kV | Very large draglines, extreme power requirements | PROTOLON (M)-R HV, FELTOFLEX HV, ANACONDA 35kV |
7.2 Insulation Materials
| Material | Designation | Max Temp | Properties | Applications |
|---|---|---|---|---|
| EPR | Ethylene Propylene Rubber (Type 3GI3) | 90°C | Excellent flexibility, mechanical strength | Most mining cables, dynamic applications |
| HEPR | Hard Ethylene Propylene Rubber | 90°C | Enhanced electrical properties, MV/HV use | Medium to high voltage cables |
| XLPE | Cross-Linked Polyethylene | 90°C | Good electrical properties, less flexible | Fixed installations, power distribution |
| PE | Polyethylene | 70°C | Good dielectric properties | Control cables, low voltage applications |
7.3 Sheath Materials
| Material | Code | Properties | Typical Applications |
|---|---|---|---|
| Chloroprene (Neoprene) | CR | Oil, chemical, weather, flame resistant | Surface mining, harsh environments |
| CM Compound | CM | Chloroprene/CSM blend, superior properties | High-end mining cables (PROTOLON, PROTOMONT) |
| Polyurethane | PUR | Excellent abrasion, oil resistance, compact | Reeling drums (TROMMELFLEX), dynamic use |
| CPE/TPU | CPE/TPU | Chlorinated PE/Thermoplastic PU blend | Asian market cables (TEMK series) |
| PVC | PVC | Cost-effective, moderate properties | Fixed installations, less demanding applications |
| LSOH/LS0H | LSOH | Low smoke, halogen-free, fire safe | Tunnels, confined underground spaces |
| PCP | PCP | Polychloroprene compound | Australian mining cables (MINEMASTER) |
7.4 Temperature Ranges
Standard Operating Temperatures:
- Fixed Installation: -40°C to +80°C
- Fully Flexible Operation: -20°C to +60°C (some to -35°C)
- Cold Resistant Variants: Down to -45°C (PROTOMONT EMV-FC)
- Maximum Conductor Temperature: 90°C (continuous)
- Short Circuit Temperature: 250°C (maximum 5 seconds)
7.5 Mechanical Properties
| Property | Typical Values | Significance |
|---|---|---|
| Tensile Strength | 6-15 N/mm² (DIN VDE), varies by type | Resistance to pulling forces during installation and operation |
| Max Tensile Load (Operation) | 20-30 N/mm² on conductor | Safe pulling force during dynamic operation |
| Elongation at Break | 200-300% | Flexibility and ability to withstand stretching |
| Minimum Bending Radius (Fixed) | 5-10× cable outer diameter | Minimum bend without damage in fixed installations |
| Minimum Bending Radius (Dynamic) | 10-15× cable outer diameter | Minimum bend for moving applications |
| Travel Speed (Reeling) | Up to 240 m/min (some unlimited) | Maximum speed for reeling drum applications |
8. Installation & Safety Guidelines
8.1 Pre-Installation Checklist
Essential Verification Steps:
- Confirm cable specifications match equipment requirements (voltage, current, application)
- Verify all required regulatory approvals are in place (MSHA, DGMS, etc.)
- Inspect cables for transport damage before installation
- Check environmental conditions match cable ratings (temperature, chemicals, water)
- Ensure proper cable storage (avoid direct sunlight, extreme temperatures)
- Verify availability of correct termination equipment and connectors
- Confirm electrical isolation and lockout/tagout procedures are in place
8.2 Installation Best Practices
Handling and Routing:
- Minimum Bending Radius: Always maintain specified minimum bending radius
- Fixed installation: 5-10× cable OD
- Flexible/dynamic operation: 10-15× cable OD
- Never exceed maximum bending angle for cable type
- Pulling Tension:
- Never exceed manufacturer’s specified pulling tension
- Use proper cable grips (Kellums grip or similar)
- Pull on conductor, not outer sheath alone
- Use lubrication where appropriate
- Cable Support:
- Support cables at regular intervals to prevent sagging
- Use appropriate cable hangers, clamps, or trays
- Avoid sharp edges and abrasive contact surfaces
- Install proper strain relief at all terminations
Termination Requirements:
- Use only approved connectors and termination kits for mining applications
- Follow manufacturer’s termination instructions precisely
- Properly terminate all screens and armour for earthing continuity
- Use appropriate sealing glands to prevent moisture ingress
- Install mechanical strain relief at every termination point
- Apply correct torque using calibrated tools
- Test all terminations before energizing (insulation resistance, continuity)
- For fiber optic terminations, use specialized technicians and tools
8.3 Application-Specific Installation Guidelines
Reeling Drum Installation:
- Ensure drum size is adequate (minimum drum diameter per cable spec)
- Wind cable in correct direction (consult manufacturer)
- Maintain even winding with no cable overlap or crossing
- Install level wind mechanism if required
- Provide adequate slip ring or collector connection
- Never allow cable to wind onto bare drum – use proper drum lagging
Festoon System Installation:
- Use correct festoon saddles or carriers for cable weight
- Maintain proper cable sag (typically 5-10% of span)
- Ensure adequate clearance for cable movement
- Provide strain relief at connection points
- Install in C-type or S-type configuration as specified
Trailing Cable Installation:
- Protect cable from direct contact with ground or machinery
- Use cable protectors at crossover points
- Ensure adequate cable length for equipment movement range
- Install proper strain relief at equipment connection
- Avoid routing near hot surfaces or sharp machinery edges
8.4 Safety Precautions
Critical Safety Rules:
- Explosive Atmospheres: In underground coal mines and methane-prone areas:
- Only use approved flame-retardant cables
- Ensure proper earthing and screening of all cables
- Never work on live cables in explosive atmospheres
- Follow methane monitoring procedures during installation
- High Voltage Work:
- Only qualified electricians may work on HV cables
- Follow all lockout/tagout procedures
- Test for dead before commencing work
- Maintain proper clearances and use insulated tools
- Mechanical Hazards:
- Never drag cables across sharp edges or rough surfaces
- Do not allow vehicles or equipment to run over cables
- Protect cables from falling rocks or debris
- Mark cable routes clearly in work areas
8.5 Maintenance Schedule
| Frequency | Inspection Tasks | Testing Required |
|---|---|---|
| Daily | Visual inspection for obvious damage, check connections | None (unless damage suspected) |
| Weekly | Detailed visual inspection of entire cable length and terminations | Continuity check if concerns |
| Monthly | Check for sheath degradation, verify strain relief, inspect reeling drums | RCD/GFCI function test |
| Quarterly | Comprehensive cable inspection, check for wear patterns | Insulation resistance, earth continuity |
| Annually | Complete system audit, review maintenance records | Full electrical testing including high voltage insulation test |
| After Incident | Full inspection after any suspected damage, impact, or fault | Complete electrical testing before re-energizing |
9. Common Problems & Solutions
Symptoms: Conductor breakage, sheath cracking, reduced flexibility after short service life
Common Causes:
- Using fixed installation cables for dynamic applications
- Insufficient flexibility rating for the specific duty cycle
- Bending radius below minimum specification
- Excessive torsional or tensile stress
Solutions:
- Specify cables designed for dynamic use (e.g., PROTOMONT, TROMMELFLEX for reeling)
- Verify flexibility class matches application requirements
- Review and correct cable routing to eliminate sharp bends
- Install proper strain relief and support systems
- Consider upgrade to higher-specification cable (e.g., Part 814 for extreme reeling applications)
Symptoms: Insulation resistance below 1 MΩ·km, earth leakage trips, possible shock hazard
Common Causes:
- Water ingress through damaged sheath or poorly sealed terminations
- Insulation degradation due to overheating
- Chemical attack from incompatible substances
- Age-related deterioration
- Physical damage to cable
Solutions:
- Identify and repair or replace damaged cable sections
- Improve termination sealing using proper glands and sealing compounds
- Verify cable is not overloaded – check current ratings
- If insulation is compromised, cable replacement is typically required
- Review chemical exposure – may need different sheath material
Symptoms: Visible cracks, hardening, or softening of outer sheath; color changes
Common Causes:
- UV exposure in surface applications (if not UV-resistant)
- Chemical incompatibility with oils, solvents, or mining chemicals
- Ozone degradation (especially rubber sheaths)
- Operating below minimum temperature rating
- Age and environmental stress
Solutions:
- Protect cables from direct sunlight – use covers or routing through conduits
- Verify chemical compatibility before installation
- Select appropriate sheath material (CR, CM, PUR) for specific environment
- Replace cables showing significant deterioration
- Consider cables with enhanced sheath properties (e.g., PROTOLON CM compound)
Symptoms: Hot connections, discoloration, burning smell, loose connections
Common Causes:
- Improper termination technique or incorrect torque
- Wrong connector size or type
- Corrosion at connection points
- Overloading beyond cable current rating
- Poor contact between connector and conductor
Solutions:
- Re-terminate using proper procedures and calibrated torque tools
- Use only approved mining-grade connectors
- Apply anti-oxidant compound to connections
- Verify load current is within cable rating
- Implement regular thermal imaging inspection program
- Replace damaged or corroded connectors immediately
Symptoms: Cable damage on drum, uneven winding, premature failure, kinking
Common Causes:
- Drum diameter too small for cable size
- Incorrect winding direction or technique
- Cable crossover or overlapping on drum
- Excessive winding speed
- Worn or damaged drum lagging
Solutions:
- Verify drum diameter meets minimum requirement (typically 20-30× cable OD)
- Install or repair level wind mechanism
- Train operators on proper reeling procedures
- Reduce operating speed if necessary
- Replace drum lagging regularly
- Consider specialized reeling cables (TROMMELFLEX, PROTOLON-R)
Symptoms: Equipment malfunction, erratic control signals, communication issues
Common Causes:
- Using unscreened cables near VFD equipment
- Improper screen termination or earthing
- Running power and signal cables in same tray without screening
- High-frequency switching from variable frequency drives
Solutions:
- Use EMC-compliant screened cables (PROTOMONT EMV-FC) for VFD applications
- Ensure proper screen/shield termination at both ends
- Separate power and signal cables with adequate spacing
- Use individually screened cables (BS 6708 types) for sensitive circuits
- Verify all screens are properly earthed
Symptoms: Insulation resistance drops in wet conditions, pump failure, electrical faults
Common Causes:
- Using non-submersible cables underwater
- Damaged sheath or terminations
- Exceeding maximum immersion depth
- Improper sealing at cable entries
Solutions:
- Use only submersible-rated cables (PROTOLON ST, TMP-NSSHOEU/NTSWOEU)
- Verify depth rating is adequate for application
- Inspect and maintain cable gland seals regularly
- Replace cables with any sheath damage immediately
- Use proper submersible termination kits
10. Cable Selection Guide
10.1 Selection Criteria
Follow this systematic approach to select the correct mining cable:
Step 1: Define Application Requirements
- Application Type:
- Reeling (continuous winding/unwinding)
- Trailing (dragging behind equipment)
- Fixed or semi-fixed installation
- Festoon (hanging system)
- Shearer chain (coal cutting)
- Environment:
- Surface/open-cast or underground
- Explosive atmosphere (methane, coal dust)
- Water/submersible requirements
- Chemical exposure
- Temperature range
- Mechanical Requirements:
- Flexibility needs (static, moderate, extreme)
- Mechanical stress level (low, medium, high, extreme)
- Bending radius constraints
- Abrasion resistance needs
Step 2: Electrical Specifications
- Voltage Rating: Select appropriate voltage class (LV, MV, HV)
- Current Rating: Calculate based on load + safety margin
- Number of Cores: Power cores + earth cores + pilot/control cores
- Conductor Size: Based on voltage drop and current requirements
- Special Features:
- Screening/shielding for EMI protection
- Fiber optic integration for data transmission
- Monitoring capabilities (IQ systems)
Step 3: Regulatory Compliance
- Identify applicable regional standards (VDE, BS, AS/NZS, MT818, ICEA, etc.)
- Verify required mining authority approvals (MSHA, DGMS, HSE, etc.)
- Confirm fire performance requirements (flame retardance, LSOH if needed)
- Check for explosive atmosphere certifications (ATEX, BASEEFA, etc.)
10.2 Quick Selection Tables
By Application Type:
| Application | First Choice | Alternative | Budget Option |
|---|---|---|---|
| Bucket Wheel Excavator (MV) | PROTOLON (M)-R | TENAX SAS | Generic VDE 250-813 cable |
| Cable Reeling Drum (LV) | TROMMELFLEX PUR-HF | PROTOLON reeling variant | Standard NSHTÖU |
| Coal Shearer | PROTOMONT (V) | TENAX CTE | Generic shearer cable |
| Underground Trailing | CORDAFLEX (S) | PROTOMONT (S) | BS 6708 Type 20/21 |
| Submersible Pump | TMP-NSSHOEU | PROTOLON (ST) | Generic submersible cable |
| Tunnel Boring | PROTOMONT TBM | TUNNELFLEX | Generic trailing cable with LSOH |
By Regional Standard:
| Region/Standard | Recommended Cable Families |
|---|---|
| Europe (DIN VDE 0250) | PROTOLON, PROTOMONT, TENAX, FELTOFLEX, TROMMELFLEX |
| UK/Commonwealth (BS 6708) | PROTOLON, PROTOMONT (BS compliant variants) |
| Australia/NZ (AS/NZS) | MINEMASTER, PROTOLON, PROTOMONT (AS/NZS compliant) |
| North America (ICEA/UL/CSA) | ANACONDA, BOSTMINE, SNAKE STRIPE, CAROL |
| China (MT818) | TEMK, MY/MYP/MYPT series |
| India (IS 14494) | PROTOLON, PROTOMONT (IS compliant) |
| Spain (UNE 22511/22520) | EPIRONED, SINTERAX, TELEFONED |
10.3 Cost vs. Performance Considerations
Premium Cables (PROTOLON, PROTOMONT, TENAX):
Advantages:
- Superior mechanical properties and durability
- Longer service life (often 2-3× standard cables)
- Better electrical performance
- Enhanced safety features
- Comprehensive global approvals
- Technical support from major manufacturers
Best For: Critical applications, harsh environments, long-term installations, high-value equipment
Standard/Budget Cables:
Advantages:
- Lower initial cost
- Adequate for less demanding applications
- Readily available
Limitations:
- Shorter service life in demanding applications
- May have limited approvals
- Less consistent quality
Best For: Temporary installations, low-stress applications, budget-constrained projects
- Reduced failure rates and downtime
- Longer replacement intervals
- Lower maintenance requirements
- Better safety record (reducing incident costs)
- Enhanced equipment protection
11. Frequently Asked Questions
Answer: PROTOLON cables are primarily designed for surface/open-cast mining reeling and trailing applications, with emphasis on medium to high voltage power transmission. PROTOMONT cables are specifically designed for underground mining, particularly coal mining, with variants optimized for shearer chains (PROTOMONT V), coal cutters (PROTOMONT Z), and general underground trailing. PROTOMONT cables typically have enhanced flame retardance and screening for explosive atmospheres.
Answer: Generally no, not without verification. Underground mining, especially in coal mines, requires cables with specific flame retardance, often metallic screening, and appropriate certifications for explosive atmospheres. Using surface cables underground may violate safety regulations and create serious hazards. Always verify that cables have the required underground mining approvals (e.g., MSHA, DGMS) before use.
Answer: Reeling cables are designed for applications where the cable is continuously wound and unwound on a cable reel or drum, such as on bucket wheel excavators or cranes. They require special construction to withstand:
- Extreme torsional stress from winding/unwinding
- High tensile loads during acceleration
- Thousands of bending cycles
- High travel speeds (up to 240 m/min or more)
Answer: Integrated fiber optic cables (like PROTOLON M-R FO) combine power and data transmission in a single cable, offering several advantages:
- Reduced installation complexity and cost (one cable instead of two)
- Real-time equipment monitoring and diagnostics
- SCADA system integration for remote control
- High-speed, interference-free data transmission
- Reduced cable management on equipment
- Enhanced safety through better monitoring
Answer:
- EPR (Ethylene Propylene Rubber): Superior for dynamic applications requiring high flexibility, mechanical strength, and frequent movement. Used in most trailing, reeling, and shearer cables. Can handle more bending cycles.
- XLPE (Cross-Linked Polyethylene): Better for fixed installations where flexibility is less critical. Good electrical properties, lower cost, but less flexible than EPR. Used in power distribution cables and fixed installations.
Answer: CM is a high-performance sheath compound used in premium mining cables (like PROTOLON and PROTOMONT). It’s typically a blend of chloroprene rubber and chlorosulfonated polyethylene (CSM/Hypalon), offering:
- Superior resistance to oils, chemicals, and weather
- Excellent flame retardance
- High abrasion resistance
- UV and ozone resistance
- Better performance than standard CR (chloroprene) alone
Answer: Replacement should be condition-based rather than time-based:
- Immediate replacement if: Conductor exposure, severe sheath damage, insulation resistance < 1 MΩ·km, any damage in explosive atmosphere areas
- Reeling cables: Typically 2-5 years in heavy use, longer in moderate use
- Trailing cables: 5-10 years depending on conditions
- Fixed installation cables: 10-20+ years with proper maintenance
Answer: These are North American portable power cable types:
- Type W: Hard-usage portable power cable, 2000V, flexible construction for mining
- Type G: Mining power cable, 5-35kV, for trailing applications on mobile equipment
- Type G-GC: Type G with ground check conductor for ground fault monitoring
- SHD-GC: Shielded design with ground check, enhanced electrical safety
- MP-GC: Mining power cable with ground check, typically for higher voltages
Answer: It depends on the damage extent and location:
- Minor sheath damage (surface only): Can be repaired with approved repair kits
- Damaged conductors or insulation: Typically requires cable replacement
- Damaged terminations: Can be re-terminated using proper procedures
- Joints: Can be made using approved jointing kits (e.g., 3M Scotchcast)
Answer: Color coding serves several purposes:
- Core Identification: Standard colors (e.g., Brown-Blue-Black for 3-phase + Green/Yellow for earth) allow proper connection
- Voltage Identification: Different outer sheath colors may indicate voltage ratings
- Application Identification: High-visibility colors (like TENAX LUMEN) improve safety
- Standards Compliance: Different standards (VDE, BS, AS/NZS) may have different color schemes
Answer: Flexibility classifications relate to the cable’s conductor class and construction:
- Class 5 (Flexible): Fine stranded conductors, suitable for most mobile applications
- Class 6 (Highly Flexible): Extra fine stranding, for severe dynamic applications
- Specific designs: Terms like “superflex” (MINEMASTER) or “ultra-flexible” (PROTOMONT V) indicate enhanced construction for extreme applications
Answer: Cable sizing involves multiple factors:
- Load Current: Equipment full load amps + safety margin (typically 125%)
- Voltage Drop: Calculate voltage drop over cable length (typically limit to 4-5%)
- Ambient Temperature: Apply de-rating factors for high temperatures
- Installation Method: Apply de-rating for grouping, burial, etc.
- Short Circuit Rating: Verify cable can handle potential fault currents
Conclusion
This comprehensive guide has covered the complete range of mining cable models available for various applications in the global mining industry. From surface excavation to deep underground operations, from low voltage control circuits to high voltage power transmission, there are specialized cables engineered to meet every requirement.
Key Takeaways:
- Application-Specific Selection: Different mining applications require different cable specifications – always match the cable to the specific application requirements
- Standards Compliance: Ensure cables comply with relevant regional standards and have necessary mining authority approvals
- Quality Matters: Premium cables from established manufacturers typically offer better long-term value through longer service life and enhanced safety
- Proper Installation: Even the best cables will fail prematurely if not installed and maintained correctly
- Safety First: In explosive atmospheres and high-risk mining environments, cable safety features are non-negotiable
- Regular Maintenance: Implement systematic inspection and testing programs to ensure ongoing safety and reliability
At Anhui Feichun Special Cable Co., Ltd., we manufacture a complete range of mining cables meeting all major international standards. Our technical team has extensive experience in mining cable applications and can provide expert guidance on cable selection, installation, and maintenance for your specific project requirements.
Our Commitment:
We are committed to providing:
- High-quality cables manufactured to international standards
- Comprehensive technical support and engineering consultation
- Competitive pricing with excellent value
- Reliable delivery and global logistics support
- After-sales service and technical assistance
- Custom cable solutions for unique applications
Contact Our Expert Team
For detailed technical specifications, custom cable solutions, quotations, or expert consultation on mining cable selection for your specific application, please contact our experienced engineering and sales team:
We provide comprehensive support including:
- Cable selection and specification assistance
- Technical drawings and certification documentation
- Installation guidance and training
- Testing services and quality assurance
- After-sales technical support
- Worldwide shipping and logistics coordination
References and Resources
This comprehensive guide is based on authoritative sources, industry standards, and manufacturer specifications:
- Prysmian Group – Mining Cable Product Mapping and Solutions
- Prysmian Mining Technology – PROTOLON and PROTOMONT Cables
- PROTOMONT (V) Coal Shearer Cable Technical Specifications
- FELTOFLEX Mining Cable Applications
- TROMMELFLEX PUR-HF Reeling Cable Specifications
- DIN VDE 0250 Series – German Standards for Power Installation Cables
- BS 6708:1998 – British Standard for Flexible Cables for Use at Mines and Quarries
- AS/NZS 1802/2802 – Australian/New Zealand Standards for Mining Cables
- MT818 Series – Chinese Standards for Mining Cables
- ICEA S-75-381 / NEMA WC-58 – North American Mining Cable Standards
- IEC 60502-1 – International Standard for Power Cables