Complete List of Mining Cable Models and Applications

Comprehensive Technical Guide to Mining Cables for Surface, Underground, and Tunneling Operations

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
Complete List of Mining Cable Models and Applications | Comprehensive Guide 2025 | Feichun Special Cable

Complete List of Mining Cable Models and Applications

Comprehensive Technical Guide to Mining Cables for Surface, Underground, and Tunneling Operations

Professional Guide by Anhui Feichun Special Cable Co., Ltd. | Updated 2025 | Covering All Major International Standards

About Anhui Feichun Special Cable Co., Ltd.

Anhui Feichun Special Cable Co., Ltd. is a premier manufacturer of specialized mining cables, offering a comprehensive range of products compliant with international standards including DIN VDE 0250, BS 6708, AS/NZS 1802, MT818, IEC, and CSA. Our mining cables are engineered for the most demanding applications in open-cast mining, underground mining, tunneling, and industrial operations worldwide.

📧 Technical Email: [email protected]
📞 International Sales: +86 13855123218

1. Introduction & Overview

Mining operations require specialized electrical cables that can withstand extreme environmental conditions, mechanical stresses, and safety requirements unique to the mining industry. This comprehensive guide catalogs all major mining cable models available for various applications, from surface excavation to deep underground operations.

What This Guide Covers:

  • Complete Cable Model Catalog: Detailed specifications for PROTOLON, PROTOMONT, TENAX, FELTOFLEX, TROMMELFLEX, ANACONDA, BOSTMINE, and more
  • Application-Specific Recommendations: Cables optimized for reeling, trailing, dredging, shearer chains, festoon systems, and fixed installations
  • International Standards Compliance: Coverage of DIN VDE 0250, BS 6708, AS/NZS 1802/2802, MT818, IEC, UL, CSA, and regional standards
  • Technical Specifications: Voltage ratings, insulation types, sheath materials, temperature ranges, and mechanical properties
  • Safety Guidelines: Installation procedures, precautions, and troubleshooting for safe mining operations

Purpose of Mining Cables

Mining cables serve critical functions in modern mining operations:

  • Power Transmission: Delivering electrical power from substations to mobile and fixed mining equipment
  • Control & Signaling: Enabling remote operation and monitoring of mining machinery
  • Data Communication: Facilitating real-time data transmission through integrated fiber optics
  • Safety Systems: Supporting critical safety and emergency communication systems

Key Characteristics Required

Extreme Flexibility: To withstand constant movement, bending, and reeling operations
Mechanical Strength: High tensile and torsional stress resistance for harsh conditions
Environmental Resistance: Protection against water, chemicals, oils, abrasion, and UV exposure
Flame Retardance: Self-extinguishing properties for underground explosive atmospheres
Temperature Performance: Operation across wide temperature ranges (-40°C to +90°C)
Electrical Safety: Proper screening, insulation, and earthing for hazardous environments

2. Major Product Families

Manufacturer: Prysmian Group

Standards: DIN VDE 0250-813/812, BS 6708, AS/NZS 1802/2802, IS 14494

Applications: Reeling and trailing cables for open-cast mining, medium to high voltage power transmission

PROTOLON Models:

  • PROTOLON (M)-R: MV reeling cable (6-35 kV) with HEPR insulation, high-grade CR sheath
  • PROTOLON (SB): MV trailing cable (6-20 kV) for excavators, EPR insulation
  • PROTOLON (ST): MV cable for underwater use (6-35 kV), dredging applications
  • PROTOLON (M)-F: MV semi-flexible cable (3-30 kV) for fixed installations with fiber optics option
  • PROTOLON SB IQ: Intelligent cable with integrated monitoring systems

Manufacturer: Prysmian Group

Standards: Based on DIN VDE 0250-813/812, BS 6708, AS/NZS 1802/2802

Applications: Underground mining, coal cutters, shearer chains, trailing operations

PROTOMONT Models:

  • PROTOMONT (V): Coal shearer cable for chain operation (LV 1 kV, MV 3-6 kV), EPR/CM
  • PROTOMONT (Z): Coal cutter cable (LV 1 kV), EPR insulation, CM sheath
  • PROTOMONT (MT): Semi-flexible cable (1 kV) with optimized dimensions for conveyor belts
  • PROTOMONT MSR: Data, signal, and control cables (250 V), PE insulation, CR sheath
  • PROTOMONT TBM: Tunnel boring machine cable (MV 6-35 kV), HEPR/chloroprene

Manufacturer: Prysmian Group

Standards: DIN VDE 0250-813/812, CZ, EPN78

Applications: Underground mining, reeling drums, trailing, festoon systems

TENAX Models:

  • TENAX CTE: Coal cutter cable (LV 1 kV), EPR/CM for shearer chain applications
  • TENAX SAS: Medium voltage cable (6-20 kV), EPR/Rubber or PUR sheath
  • TENAX LUMEN: Enhanced visibility cable (MV 6-20 kV) with high-visibility sheath
  • TENAX HTT: High-temperature tunnel cable (MV 6-35 kV), HEPR/chloroprene
  • TENAX-LWL: Fiber optic cable for optical data transmission in mining

Manufacturer: Prysmian Group

Standards: DIN VDE 0250-813/812

Applications: Single-core MV cables, switch-gear connections, mobile transformers

FELTOFLEX Models:

  • FELTOFLEX NTMCWOEU: MV single-core cable with cold-removable semi-conductive layer
  • FELTOFLEX (Standard): Highly flexible connection for substations, generators (3-35 kV)
  • FELTOFLEX HV: High voltage cables (66-155 kV) for extreme flexibility applications

Manufacturer: Prysmian Group

Standards: Based on DIN VDE 0250-813/812

Applications: Reeling drums, hoisting equipment, conveyor systems

TROMMELFLEX Models:

  • TROMMELFLEX M-PUR: LV 1 kV reeling cable with polyurethane sheath
  • TROMMELFLEX PUR-HF: Halogen-free PUR cable for heavy-duty reeling applications
  • TROMMELFLEX (Standard): EPR insulation, CM sheath for underground reeling

Manufacturer: Prysmian Group

Standards: Based on DIN VDE 0250, BS 6708, AS/NZS 1802/2802

Applications: Fiber optic communication cables for mining installations

OPTOFLEX Models:

  • OPTOFLEX (M): Rubber-sheathed flexible fiber optic cable, suitable for underground
  • OPTOFLEX (M) FO: Fiber optic cable with multiple fiber types (G50/125, G62.5/125, E9/125)

Manufacturer: Prysmian Group

Standards: Based on DIN VDE 0250-813/812, BS 6708, AS/NZS 1802/2802

Applications: Medium voltage flexible power cables, fixed and semi-fixed installations

SUPROMONT Models:

  • SUPROMONT: MV flexible cable (6-35 kV), HEPR insulation, PVC/Compound/LSOH sheath
  • SUPROMONT (Fixed): For semi-fixed installations in underground mines

Manufacturer: Prysmian Group

Standards: Based on DIN VDE 0250-813/812, BS 6708, AS/NZS 1802/2802

Applications: Low voltage flexible cables for scoops and jumbo drills

CORDAFLEX Models:

  • CORDAFLEX (S): LV 1 kV cable, EPR/CM for trailing operations
  • PROTOMONT (S): Similar specification for shearer chain applications

Manufacturer: Various (North American manufacturers)

Standards: ICEA, UL, CSA

Applications: North American mining operations, surface and underground

ANACONDA Models:

  • Anaconda Types W, G, G-GC: 2 kV to 35 kV SHD-GC portable power cables
  • Anaconda Type SHD-GC: Shielded cables (5-35 kV) for medium voltage applications
  • Anaconda Type MP-GC: Mining power cables (5-35 kV) with ground check conductors
  • Snake Stripe: High-visibility mining cables with distinctive stripe patterns

Manufacturer: Various

Standards: CSA

Applications: Canadian mining operations, trailing and reeling applications

BOSTMINE Models:

  • Bostmine Types W, G, G-GC: 2 kV to 35 kV SHD-GC cables
  • Bostmine Type SHD-GC: 2 kV to 35 kV shielded trailing cables
  • Bostmine Type MP-GC: 5-35 kV mining power cables

Manufacturer: Various (Australian/Asian manufacturers)

Standards: ICEA S-75-381, IEC 60502-1, Based on VDE 0250 and BS6708

Applications: International mining operations

Mineflex Models:

  • Mineflex: Based on VDE 250 parts, IEC 60502-1, ICEA S-93-639
  • Mineflex TPU 0.6/1kV: EPR insulation, TPU outer sheath
  • EATFEVA RZT 0.6/1kV: Excellent tear and notch resistance

Manufacturer: Various

Standards: AS/NZS 1802/2802

Applications: Australian and New Zealand mining operations

MINEMASTER Models:

  • TXA9 3.3/11kV: EPR insulation, PCP sheath, reeling applications
  • TXA9 11/22kV: EPR insulation for coal/metalliferous mines
  • TX55 3.3/11kV: Superflex EPR insulation, PCP sheath
  • TX75 11kV: EPR insulation for reeling applications
  • TXA1 1.1/1.1kV: EPR insulation, PCP sheath, superflex trailing
  • TXA1 and TXA1 superflex: 1.1/1.1kV for festoon, shearer, and reeling

Manufacturer: Various (Asian manufacturers)

Standards: MT818, VDE 0250 (LV, MV), ICEA S-75-381 (MV)

Applications: Chinese and international mining operations

TEMK Models:

  • TEMK TUNC: Low voltage cable for underground mining
  • TEHF FLEX: High flexibility trailing cable
  • TEMK TD/HDGC3-C: MV cable, EPR/CPE/TPU sheath
  • MSPB: 0.6/1 kV (N)SHTOEU-J, EPR/CPE/TPU construction
  • MY/MYP/MYPT: Chinese standard mining cables (0.66/1.14kV, 1.9/3.3kV)

Manufacturer: Prysmian Group

Standards: IEC 60502-1 (LV), VDE 0250 (LV, MV), ICEA S-75-381, AS/NZS 2802 (MV)

Applications: Tunneling operations, underground mining

TUNNELFLEX Models:

  • TUNNELFLEX: MV 6-20 kV, HEPR insulation, high-grade chloroprene sheath
  • PANZERFLEX: Armored version for enhanced mechanical protection
  • TUNNELFLEX TK: 1 kV HEPR insulation for tunnel boring machines

Manufacturer: Various (European manufacturers)

Standards: UNE 22511, UNE 22520, UNE 22515-1/2, UNE 22561

Applications: European (Spanish) mining operations

Models:

  • EPIRONED MINAS: 1 kV-6 kV EPR insulation, HEPR outer sheath, PVC compound
  • SINTERAX MINAS: 0 kV EPR insulation, PVC outer sheath
  • TELEFONED E SINTERAX: Control and signaling cables
  • TELEFONED LV 500V: PE insulation, PVC outer sheath
  • SINTERAX LV: 0 kV EPR insulation, PVC compound sheath

3. Surface/Opencast Mining Cables

Surface mining operations require cables that can withstand harsh outdoor environments, including extreme temperatures, UV exposure, moisture, and mechanical abuse from heavy equipment.

3.1 Reeling Applications

Application Description: Cables for equipment with cable reeling systems, including bucket wheel excavators, draglines, stackers, and reclaimers. These cables must withstand continuous winding/unwinding, high torsional stress, and extreme mechanical forces.
🏗️
Bucket Wheel Excavators

Recommended Cables:

  • PROTOLON (M)-R (MV 6-35 kV)
  • TENAX SAS (MV 6-20 kV)
  • TROMMELFLEX M-PUR (LV)
  • ANACONDA Type W, G (2-35 kV)
⚙️
Dragline Excavators

Recommended Cables:

  • PROTOLON (M)-R IQ (with monitoring)
  • FELTOFLEX (MV single-core)
  • MINEMASTER TXA9 (AS/NZS)
🔄
Stackers & Reclaimers

Recommended Cables:

  • PROTOLON (M)-R with fiber optics
  • TENAX LUMEN (high visibility)
  • TROMMELFLEX PUR-HF

3.2 Trailing Applications

Application Description: Flexible cables that trail behind mobile equipment like electric shovels, hydraulic excavators, crushers, and mobile drills. Must resist abrasion, impact, and environmental exposure.
Equipment TypeCable ModelVoltage RatingKey Features
Electric ShovelsPROTOLON (SB)MV 6-20 kVEPR insulation, CR sheath, high flexibility
Hydraulic ExcavatorsTENAX SAS / ANACONDA SHD-GC2-35 kVRubber/PUR sheath, extreme mechanical resistance
CrushersPROTOMONT (MT)LV 1 kVSemi-flexible, optimized dimensions
Mobile DrillsCORDAFLEX (S)LV 1 kVEPR/CM, compact design
Coal CuttersBOSTMINE W/G Type2-35 kVCSA certified, shielded construction

3.3 Dredging Applications

🚢
Cutter Suction Dredgers

Recommended Cables:

  • PROTOLON (ST) – MV 6-35 kV
  • Insulation: HEPR
  • Sheath: CM (water resistant)
  • Special feature: Continuous underwater operation
⛏️
Submersible Pumps

Recommended Cables:

  • TMP-NSSHOEU (LV)
  • TMP-NTSWOEU (MV 1.8/3, 3.6/6 kV)
  • Water immersion depth: up to 1000m

3.4 Semi-Flexible Applications

For equipment requiring limited movement or periodic repositioning:

  • PROTOLON (M)-F: MV 3-30 kV, for conveyors and shiftable units
  • PROTOMONT (MT): LV 1 kV, optimized for conveyor belt installations
  • SUPROMONT: MV 6-35 kV, for semi-fixed installations

3.5 Single Core Applications

Medium to high voltage single-core cables for specialized installations:

  • FELTOFLEX NTMCWOEU: MV 6-35 kV, switch-gear connections, mobile transformers
  • PROTOLON (M) Single Core: MV 6-35 kV, optimized dimensions
  • FELTOFLEX HV: 66-155 kV, extreme flexibility for constrained spaces

3.6 Control & Signaling

Low voltage cables for control circuits and data transmission:

  • PROTOMONT MSR: 250 V, PE insulation, CR sheath
  • OPTOFLEX (M): Fiber optic cables for data communication
  • TEMK Control Cables: Multi-core control and signaling

4. Underground Mining Cables

Underground mining presents unique challenges including explosive atmospheres (methane, coal dust), confined spaces, high humidity, and stringent safety requirements. All cables must be flame-retardant and often require metallic screening for electrical safety.

4.1 Shearer Chain Applications

Application Description: Cables for coal face shearer machines that move along the longwall face. These cables are subjected to extreme mechanical stress, frequent bending, and must operate in explosive atmospheres.
PROTOMONT (V) – Coal Shearer Cable LV: 1 kV | MV: 3-6 kV
DIN VDE 0250-813 BS 6708 Flame Retardant
  • Insulation: EPR (Ethylene Propylene Rubber)
  • Outer Sheath: CM (Chloroprene/Chlorosulfonated Polyethylene)
  • Construction: Double concentric control/PE conductors
  • Temperature Range: -20°C to +60°C (flexible operation)
  • Special Features: Ultra-high flexibility, torsion resistant, MSHA approved
PROTOMONT (Z) – Coal Cutter Cable LV: 1 kV
DIN VDE 0250-813 Underground Use
  • Insulation: EPR Type 3GI3
  • Outer Sheath: CM compound
  • Applications: Continuous miners, roadheaders
TENAX CTE – Coal Cutter Cable LV: 1 kV

Similar specifications to PROTOMONT (V) for shearer chain applications, EPR insulation with CM sheath.

4.2 Trailing Applications (Underground)

Flexible cables for mobile equipment in underground mines:

Cable ModelVoltageApplicationStandards
CORDAFLEX (S) / PROTOMONT (S)LV 1 kVShuttle cars, LHD vehicles, utility vehiclesDIN VDE 0250-813
TENAX (Standard)LV 1 kVUnderground mobile equipmentDIN VDE 0250-813
ANACONDA W, G, G-GC2-35 kVHigh voltage trailing applicationsICEA, UL, CSA
MINEMASTER TXA11.1/1.1 kVSuperflex trailing for coal/metalliferousAS/NZS 1802
TEMK TD/HDGC3-C1.9/3.3 kVChinese standard underground trailingMT818

4.3 Reeling Applications (Underground)

🔌
Cable Reels Underground

Recommended Cables:

  • TROMMELFLEX M-PUR (LV 1 kV)
  • TENAX LK (reeling drum variant)
  • Mineflex TPU 0.6/1kV
  • MINEMASTER TX75 11kV (reeling)
📡
Communication Systems

Recommended Cables:

  • TENAX-LWL (Fiber optic)
  • OPTOFLEX (M) (Underground rated)
  • TELEFONED (Control cables)

4.4 Festoon Systems

Application Description: Cables suspended in festoon systems for continuous miner power supply, conveyor systems, and monorail applications. Must withstand constant movement and hanging stress.
  • PROTOMONT: 1kV and 6kV variants, EPR/CM construction
  • TUNNELFLEX: MV 6-20 kV, HEPR/chloroprene for tunnel festoons
  • MINEMASTER TXA1 Superflex: Designed for festoon applications (AS/NZS)
  • MY/MYP/MYPT: Chinese standard festoon cables

4.5 Control & Signaling (Underground)

Cable TypeVoltageApplication
PROTOMONT MSR250 VData, signal, and control circuits, PE insulation
OPTOFLEX (M)N/AFiber optic communication, underground monitoring
TELEFONED E SINTERAX500VSpanish standard control and signaling
SINTERAX LV0 kVLow voltage control circuits

4.6 Fixed Installation (Underground)

Cables for permanent or semi-permanent underground power distribution:

SUPROMONT: MV 6-35 kV, HEPR/PVC or LSOH sheath
SINTERAX 1V: 0 kV-6 kV EPR insulation, PVC sheath
EPIRONED: 1-6 kV EPR/HEPR, PVC compound (UNE 22511)
ANACONDA 5-35kV MP-GC: Fixed installation with ground check

4.7 Semi-Fixed Installation (Underground)

  • PROTOMONT (Semi-Fixed): 1 kV EPR/CM or 6-35 kV HEPR/PVC
  • SUPROMONT: MV 6-35 kV for semi-fixed power distribution
  • TUNNELFLEX TK: 1 kV HEPR for tunnel installations

5. Specialized Applications

5.1 Tunneling Operations

Tunnel Boring Machines (TBM)

  • PROTOMONT TBM: MV 6-35 kV, HEPR/high-grade chloroprene or LSOH
  • TUNNELFLEX: MV 6-20 kV, HEPR/chloroprene compound
  • TENAX HTT: MV 6-35 kV, high-temperature tunnel cable
  • ANACONDA Types W, G: 2-35 kV for tunnel construction
Special Requirements for Tunneling:
  • Enhanced fire performance (LSOH options preferred)
  • Resistance to water, concrete additives, and chemicals
  • High mechanical strength for trailing through rough terrain
  • Extended lengths to minimize joints (up to several kilometers)

5.2 Underwater/Submersible Applications

Cable ModelMax DepthApplication
PROTOLON (ST)Continuous underwaterDredging operations, underwater excavation
TMP-NSSHOEUUp to 1000mDeep submersible pumps
TMP-NTSWOEUUp to 1000mMV submersible applications (1.8/3, 3.6/6 kV)
TROMMELFLEX PUR-HF50mWet environments, temporary water immersion

5.3 Fiber Optic Integration

Modern mining operations increasingly require integrated power and data transmission:

PROTOLON (M)-R FO MV 3.6/6 – 20/35 kV
  • Fiber Types Available: G50/125, G62.5/125, E9/125
  • Fiber Count: 4-24 fibers (customizable)
  • Application: Real-time monitoring, automation control, SCADA systems
  • Benefits: Single cable solution for power + communication
OPTOFLEX (M) Communication Only

Dedicated fiber optic cable for mining installations, rubber sheath, suitable for underground use. Available in G50/125, G62.5/125, E9/125 fiber specifications.

TENAX-LWL Data Transmission

Rubber-sheathed fiber optic cable specifically designed for mining data transmission networks.

5.4 High Visibility Cables

TENAX LUMEN – Enhanced Visibility Cable
MV 6-20 kV with high-visibility colored PUR sheath. Ideal for safety-critical applications where cable location must be easily identified. Applications include:
  • Surface mining in low-light conditions
  • Underground installations requiring easy identification
  • Emergency evacuation route marking
  • Safety zone delineation

5.5 Extreme Temperature Applications

Temperature RangeRecommended CableSpecial Features
Very Cold (-45°C)PROTOMONT EMV-FC (-45°C)Cold-resistant LSOH sheath, screened for VFD
High TemperatureTENAX HTTHigh-temperature tunnel cable, enhanced thermal rating
Wide Range (-40°C to +80°C)PROTOLON (M)-RFixed installation capability across extreme ranges

5.6 EMC Compliant Cables (VFD Applications)

For Variable Frequency Drive (VFD) applications requiring electromagnetic compatibility:

  • PROTOMONT EMV-FC (N)SSHCOEU: LV screened cable, EMC compliant for VFD
  • PROTOMONT EMV-FC (-45°C): Cold-resistant variant
  • Special features: Copper screening, low impedance, reduced EMI emissions

6. Standards & Compliance

6.1 International Standards Coverage

StandardRegionCable Families CoveredKey Requirements
DIN VDE 0250Germany/EuropePROTOLON, PROTOMONT, TENAX, FELTOFLEX, TROMMELFLEXParts 812, 813, 814 – Flexible cables for power installations
BS 6708UK/CommonwealthPROTOLON, PROTOMONT equivalentsFlexible cables for mines and quarries, various types
AS/NZS 1802/2802Australia/NZMINEMASTER, PROTOLON, PROTOMONTElastomeric cables for mines and quarries
MT818ChinaTEMK, MY/MYP/MYPT seriesRubber-sheathed flexible cables for coal mines
ICEA/UL/CSANorth AmericaANACONDA, BOSTMINE, SNAKE STRIPE, CAROLPortable power cables for mining applications
IS 14494IndiaPROTOLON, PROTOMONT equivalentsFlexible cables for mining applications
UNE 22511/22520Spain/EuropeEPIRONED, SINTERAX, TELEFONEDCables for underground mining installations
IEC 60502-1InternationalTUNNELFLEX, PANZERFLEX, MineflexPower cables with extruded insulation

6.2 Mining Authority Approvals

MSHA (USA): Mine Safety and Health Administration approval required for US operations
DGMS (India): Directorate General of Mines Safety approval
HSE (UK): Health and Safety Executive compliance
BASEEFA: British certification for explosive atmospheres
ATEX: European explosive atmosphere certification
BAS: Bosnia-Herzegovina approval
EAC: Eurasian Conformity mark
MA China: Chinese mining approval
Critical Compliance Note: Always verify that cables have the necessary approvals for your specific jurisdiction and application. Using unapproved cables in mining operations can result in:
  • Regulatory violations and mine closure orders
  • Safety hazards and increased accident risk
  • Voided insurance coverage
  • Legal liability for operators and suppliers

6.3 Fire Performance Standards

Test StandardRequirementCable Types
DIN EN 60332-1-2 / IEC 60332-1-2Single vertical wire flame testAll mining cables
VDE 0482-332-1-2Flame retardance, halogen-free optionsTROMMELFLEX PUR-HF, LSOH variants
BS 6708 Fire TestsSpecific flame retardance requirementsBS 6708 compliant cables
AS/NZS StandardsAustralian fire performanceMINEMASTER series

7. Technical Specifications Summary

7.1 Voltage Ratings Overview

Voltage ClassTypical Ratings (U0/U)ApplicationsCable Examples
Extra Low Voltage250V, 320/550VControl, signaling, pilot circuitsPROTOMONT MSR, BS 6708 Types 506-524
Low Voltage0.6/1 kV, 640/1100V, 1.1/1.1 kVMobile equipment, general power distributionPROTOMONT (V/Z/S), CORDAFLEX, MINEMASTER TXA1
Medium Voltage1.9/3.3 kV, 3.6/6 kV, 6.6/11 kVLarge excavators, high-power equipmentPROTOLON (M)-R, TENAX SAS, ANACONDA SHD-GC
High Voltage20/35 kV, 66-155 kVVery large draglines, extreme power requirementsPROTOLON (M)-R HV, FELTOFLEX HV, ANACONDA 35kV

7.2 Insulation Materials

MaterialDesignationMax TempPropertiesApplications
EPREthylene Propylene Rubber (Type 3GI3)90°CExcellent flexibility, mechanical strengthMost mining cables, dynamic applications
HEPRHard Ethylene Propylene Rubber90°CEnhanced electrical properties, MV/HV useMedium to high voltage cables
XLPECross-Linked Polyethylene90°CGood electrical properties, less flexibleFixed installations, power distribution
PEPolyethylene70°CGood dielectric propertiesControl cables, low voltage applications

7.3 Sheath Materials

MaterialCodePropertiesTypical Applications
Chloroprene (Neoprene)CROil, chemical, weather, flame resistantSurface mining, harsh environments
CM CompoundCMChloroprene/CSM blend, superior propertiesHigh-end mining cables (PROTOLON, PROTOMONT)
PolyurethanePURExcellent abrasion, oil resistance, compactReeling drums (TROMMELFLEX), dynamic use
CPE/TPUCPE/TPUChlorinated PE/Thermoplastic PU blendAsian market cables (TEMK series)
PVCPVCCost-effective, moderate propertiesFixed installations, less demanding applications
LSOH/LS0HLSOHLow smoke, halogen-free, fire safeTunnels, confined underground spaces
PCPPCPPolychloroprene compoundAustralian mining cables (MINEMASTER)

7.4 Temperature Ranges

Standard Operating Temperatures:

  • Fixed Installation: -40°C to +80°C
  • Fully Flexible Operation: -20°C to +60°C (some to -35°C)
  • Cold Resistant Variants: Down to -45°C (PROTOMONT EMV-FC)
  • Maximum Conductor Temperature: 90°C (continuous)
  • Short Circuit Temperature: 250°C (maximum 5 seconds)

7.5 Mechanical Properties

PropertyTypical ValuesSignificance
Tensile Strength6-15 N/mm² (DIN VDE), varies by typeResistance to pulling forces during installation and operation
Max Tensile Load (Operation)20-30 N/mm² on conductorSafe pulling force during dynamic operation
Elongation at Break200-300%Flexibility and ability to withstand stretching
Minimum Bending Radius (Fixed)5-10× cable outer diameterMinimum bend without damage in fixed installations
Minimum Bending Radius (Dynamic)10-15× cable outer diameterMinimum bend for moving applications
Travel Speed (Reeling)Up to 240 m/min (some unlimited)Maximum speed for reeling drum applications

8. Installation & Safety Guidelines

8.1 Pre-Installation Checklist

Essential Verification Steps:

  1. Confirm cable specifications match equipment requirements (voltage, current, application)
  2. Verify all required regulatory approvals are in place (MSHA, DGMS, etc.)
  3. Inspect cables for transport damage before installation
  4. Check environmental conditions match cable ratings (temperature, chemicals, water)
  5. Ensure proper cable storage (avoid direct sunlight, extreme temperatures)
  6. Verify availability of correct termination equipment and connectors
  7. Confirm electrical isolation and lockout/tagout procedures are in place

8.2 Installation Best Practices

Handling and Routing:

  • Minimum Bending Radius: Always maintain specified minimum bending radius
    • Fixed installation: 5-10× cable OD
    • Flexible/dynamic operation: 10-15× cable OD
    • Never exceed maximum bending angle for cable type
  • Pulling Tension:
    • Never exceed manufacturer’s specified pulling tension
    • Use proper cable grips (Kellums grip or similar)
    • Pull on conductor, not outer sheath alone
    • Use lubrication where appropriate
  • Cable Support:
    • Support cables at regular intervals to prevent sagging
    • Use appropriate cable hangers, clamps, or trays
    • Avoid sharp edges and abrasive contact surfaces
    • Install proper strain relief at all terminations

Termination Requirements:

Critical Termination Rules:
  • Use only approved connectors and termination kits for mining applications
  • Follow manufacturer’s termination instructions precisely
  • Properly terminate all screens and armour for earthing continuity
  • Use appropriate sealing glands to prevent moisture ingress
  • Install mechanical strain relief at every termination point
  • Apply correct torque using calibrated tools
  • Test all terminations before energizing (insulation resistance, continuity)
  • For fiber optic terminations, use specialized technicians and tools

8.3 Application-Specific Installation Guidelines

Reeling Drum Installation:

  • Ensure drum size is adequate (minimum drum diameter per cable spec)
  • Wind cable in correct direction (consult manufacturer)
  • Maintain even winding with no cable overlap or crossing
  • Install level wind mechanism if required
  • Provide adequate slip ring or collector connection
  • Never allow cable to wind onto bare drum – use proper drum lagging

Festoon System Installation:

  • Use correct festoon saddles or carriers for cable weight
  • Maintain proper cable sag (typically 5-10% of span)
  • Ensure adequate clearance for cable movement
  • Provide strain relief at connection points
  • Install in C-type or S-type configuration as specified

Trailing Cable Installation:

  • Protect cable from direct contact with ground or machinery
  • Use cable protectors at crossover points
  • Ensure adequate cable length for equipment movement range
  • Install proper strain relief at equipment connection
  • Avoid routing near hot surfaces or sharp machinery edges

8.4 Safety Precautions

Critical Safety Rules:

  • Explosive Atmospheres: In underground coal mines and methane-prone areas:
    • Only use approved flame-retardant cables
    • Ensure proper earthing and screening of all cables
    • Never work on live cables in explosive atmospheres
    • Follow methane monitoring procedures during installation
  • High Voltage Work:
    • Only qualified electricians may work on HV cables
    • Follow all lockout/tagout procedures
    • Test for dead before commencing work
    • Maintain proper clearances and use insulated tools
  • Mechanical Hazards:
    • Never drag cables across sharp edges or rough surfaces
    • Do not allow vehicles or equipment to run over cables
    • Protect cables from falling rocks or debris
    • Mark cable routes clearly in work areas

8.5 Maintenance Schedule

FrequencyInspection TasksTesting Required
DailyVisual inspection for obvious damage, check connectionsNone (unless damage suspected)
WeeklyDetailed visual inspection of entire cable length and terminationsContinuity check if concerns
MonthlyCheck for sheath degradation, verify strain relief, inspect reeling drumsRCD/GFCI function test
QuarterlyComprehensive cable inspection, check for wear patternsInsulation resistance, earth continuity
AnnuallyComplete system audit, review maintenance recordsFull electrical testing including high voltage insulation test
After IncidentFull inspection after any suspected damage, impact, or faultComplete electrical testing before re-energizing

9. Common Problems & Solutions

Problem: Premature Cable Failure in Dynamic Applications

Symptoms: Conductor breakage, sheath cracking, reduced flexibility after short service life

Common Causes:

  • Using fixed installation cables for dynamic applications
  • Insufficient flexibility rating for the specific duty cycle
  • Bending radius below minimum specification
  • Excessive torsional or tensile stress

Solutions:

  • Specify cables designed for dynamic use (e.g., PROTOMONT, TROMMELFLEX for reeling)
  • Verify flexibility class matches application requirements
  • Review and correct cable routing to eliminate sharp bends
  • Install proper strain relief and support systems
  • Consider upgrade to higher-specification cable (e.g., Part 814 for extreme reeling applications)
Problem: Reduced Insulation Resistance

Symptoms: Insulation resistance below 1 MΩ·km, earth leakage trips, possible shock hazard

Common Causes:

  • Water ingress through damaged sheath or poorly sealed terminations
  • Insulation degradation due to overheating
  • Chemical attack from incompatible substances
  • Age-related deterioration
  • Physical damage to cable

Solutions:

  • Identify and repair or replace damaged cable sections
  • Improve termination sealing using proper glands and sealing compounds
  • Verify cable is not overloaded – check current ratings
  • If insulation is compromised, cable replacement is typically required
  • Review chemical exposure – may need different sheath material
Problem: Sheath Deterioration and Cracking

Symptoms: Visible cracks, hardening, or softening of outer sheath; color changes

Common Causes:

  • UV exposure in surface applications (if not UV-resistant)
  • Chemical incompatibility with oils, solvents, or mining chemicals
  • Ozone degradation (especially rubber sheaths)
  • Operating below minimum temperature rating
  • Age and environmental stress

Solutions:

  • Protect cables from direct sunlight – use covers or routing through conduits
  • Verify chemical compatibility before installation
  • Select appropriate sheath material (CR, CM, PUR) for specific environment
  • Replace cables showing significant deterioration
  • Consider cables with enhanced sheath properties (e.g., PROTOLON CM compound)
Problem: Connector/Termination Overheating

Symptoms: Hot connections, discoloration, burning smell, loose connections

Common Causes:

  • Improper termination technique or incorrect torque
  • Wrong connector size or type
  • Corrosion at connection points
  • Overloading beyond cable current rating
  • Poor contact between connector and conductor

Solutions:

  • Re-terminate using proper procedures and calibrated torque tools
  • Use only approved mining-grade connectors
  • Apply anti-oxidant compound to connections
  • Verify load current is within cable rating
  • Implement regular thermal imaging inspection program
  • Replace damaged or corroded connectors immediately
Problem: Reeling Drum Issues

Symptoms: Cable damage on drum, uneven winding, premature failure, kinking

Common Causes:

  • Drum diameter too small for cable size
  • Incorrect winding direction or technique
  • Cable crossover or overlapping on drum
  • Excessive winding speed
  • Worn or damaged drum lagging

Solutions:

  • Verify drum diameter meets minimum requirement (typically 20-30× cable OD)
  • Install or repair level wind mechanism
  • Train operators on proper reeling procedures
  • Reduce operating speed if necessary
  • Replace drum lagging regularly
  • Consider specialized reeling cables (TROMMELFLEX, PROTOLON-R)
Problem: Electromagnetic Interference (EMI)

Symptoms: Equipment malfunction, erratic control signals, communication issues

Common Causes:

  • Using unscreened cables near VFD equipment
  • Improper screen termination or earthing
  • Running power and signal cables in same tray without screening
  • High-frequency switching from variable frequency drives

Solutions:

  • Use EMC-compliant screened cables (PROTOMONT EMV-FC) for VFD applications
  • Ensure proper screen/shield termination at both ends
  • Separate power and signal cables with adequate spacing
  • Use individually screened cables (BS 6708 types) for sensitive circuits
  • Verify all screens are properly earthed
Problem: Water Ingress in Submersible Applications

Symptoms: Insulation resistance drops in wet conditions, pump failure, electrical faults

Common Causes:

  • Using non-submersible cables underwater
  • Damaged sheath or terminations
  • Exceeding maximum immersion depth
  • Improper sealing at cable entries

Solutions:

  • Use only submersible-rated cables (PROTOLON ST, TMP-NSSHOEU/NTSWOEU)
  • Verify depth rating is adequate for application
  • Inspect and maintain cable gland seals regularly
  • Replace cables with any sheath damage immediately
  • Use proper submersible termination kits

10. Cable Selection Guide

10.1 Selection Criteria

Follow this systematic approach to select the correct mining cable:

Step 1: Define Application Requirements

  1. Application Type:
    • Reeling (continuous winding/unwinding)
    • Trailing (dragging behind equipment)
    • Fixed or semi-fixed installation
    • Festoon (hanging system)
    • Shearer chain (coal cutting)
  2. Environment:
    • Surface/open-cast or underground
    • Explosive atmosphere (methane, coal dust)
    • Water/submersible requirements
    • Chemical exposure
    • Temperature range
  3. Mechanical Requirements:
    • Flexibility needs (static, moderate, extreme)
    • Mechanical stress level (low, medium, high, extreme)
    • Bending radius constraints
    • Abrasion resistance needs

Step 2: Electrical Specifications

  1. Voltage Rating: Select appropriate voltage class (LV, MV, HV)
  2. Current Rating: Calculate based on load + safety margin
  3. Number of Cores: Power cores + earth cores + pilot/control cores
  4. Conductor Size: Based on voltage drop and current requirements
  5. Special Features:
    • Screening/shielding for EMI protection
    • Fiber optic integration for data transmission
    • Monitoring capabilities (IQ systems)

Step 3: Regulatory Compliance

  • Identify applicable regional standards (VDE, BS, AS/NZS, MT818, ICEA, etc.)
  • Verify required mining authority approvals (MSHA, DGMS, HSE, etc.)
  • Confirm fire performance requirements (flame retardance, LSOH if needed)
  • Check for explosive atmosphere certifications (ATEX, BASEEFA, etc.)

10.2 Quick Selection Tables

By Application Type:

ApplicationFirst ChoiceAlternativeBudget Option
Bucket Wheel Excavator (MV)PROTOLON (M)-RTENAX SASGeneric VDE 250-813 cable
Cable Reeling Drum (LV)TROMMELFLEX PUR-HFPROTOLON reeling variantStandard NSHTÖU
Coal ShearerPROTOMONT (V)TENAX CTEGeneric shearer cable
Underground TrailingCORDAFLEX (S)PROTOMONT (S)BS 6708 Type 20/21
Submersible PumpTMP-NSSHOEUPROTOLON (ST)Generic submersible cable
Tunnel BoringPROTOMONT TBMTUNNELFLEXGeneric trailing cable with LSOH

By Regional Standard:

Region/StandardRecommended Cable Families
Europe (DIN VDE 0250)PROTOLON, PROTOMONT, TENAX, FELTOFLEX, TROMMELFLEX
UK/Commonwealth (BS 6708)PROTOLON, PROTOMONT (BS compliant variants)
Australia/NZ (AS/NZS)MINEMASTER, PROTOLON, PROTOMONT (AS/NZS compliant)
North America (ICEA/UL/CSA)ANACONDA, BOSTMINE, SNAKE STRIPE, CAROL
China (MT818)TEMK, MY/MYP/MYPT series
India (IS 14494)PROTOLON, PROTOMONT (IS compliant)
Spain (UNE 22511/22520)EPIRONED, SINTERAX, TELEFONED

10.3 Cost vs. Performance Considerations

Premium Cables (PROTOLON, PROTOMONT, TENAX):

Advantages:

  • Superior mechanical properties and durability
  • Longer service life (often 2-3× standard cables)
  • Better electrical performance
  • Enhanced safety features
  • Comprehensive global approvals
  • Technical support from major manufacturers

Best For: Critical applications, harsh environments, long-term installations, high-value equipment

Standard/Budget Cables:

Advantages:

  • Lower initial cost
  • Adequate for less demanding applications
  • Readily available

Limitations:

  • Shorter service life in demanding applications
  • May have limited approvals
  • Less consistent quality

Best For: Temporary installations, low-stress applications, budget-constrained projects

Important Note on Cost: While premium cables have higher upfront costs, total cost of ownership is often lower due to:
  • Reduced failure rates and downtime
  • Longer replacement intervals
  • Lower maintenance requirements
  • Better safety record (reducing incident costs)
  • Enhanced equipment protection
For critical mining equipment, the cost of cable failure (equipment downtime, production loss, safety incidents) far exceeds the price difference between premium and budget cables.

11. Frequently Asked Questions

Q1: What’s the difference between PROTOLON and PROTOMONT cables?

Answer: PROTOLON cables are primarily designed for surface/open-cast mining reeling and trailing applications, with emphasis on medium to high voltage power transmission. PROTOMONT cables are specifically designed for underground mining, particularly coal mining, with variants optimized for shearer chains (PROTOMONT V), coal cutters (PROTOMONT Z), and general underground trailing. PROTOMONT cables typically have enhanced flame retardance and screening for explosive atmospheres.

Q2: Can I use a surface mining cable underground?

Answer: Generally no, not without verification. Underground mining, especially in coal mines, requires cables with specific flame retardance, often metallic screening, and appropriate certifications for explosive atmospheres. Using surface cables underground may violate safety regulations and create serious hazards. Always verify that cables have the required underground mining approvals (e.g., MSHA, DGMS) before use.

Q3: What does “reeling cable” mean and why are they special?

Answer: Reeling cables are designed for applications where the cable is continuously wound and unwound on a cable reel or drum, such as on bucket wheel excavators or cranes. They require special construction to withstand:

  • Extreme torsional stress from winding/unwinding
  • High tensile loads during acceleration
  • Thousands of bending cycles
  • High travel speeds (up to 240 m/min or more)
Specialized reeling cables like TROMMELFLEX PUR-HF have compact designs, enhanced flexibility, and reinforced construction to handle these stresses.

Q4: What are the advantages of integrated fiber optic cables?

Answer: Integrated fiber optic cables (like PROTOLON M-R FO) combine power and data transmission in a single cable, offering several advantages:

  • Reduced installation complexity and cost (one cable instead of two)
  • Real-time equipment monitoring and diagnostics
  • SCADA system integration for remote control
  • High-speed, interference-free data transmission
  • Reduced cable management on equipment
  • Enhanced safety through better monitoring
They’re ideal for modern automated mining operations requiring both power and communication.

Q5: How do I choose between EPR and XLPE insulation?

Answer:

  • EPR (Ethylene Propylene Rubber): Superior for dynamic applications requiring high flexibility, mechanical strength, and frequent movement. Used in most trailing, reeling, and shearer cables. Can handle more bending cycles.
  • XLPE (Cross-Linked Polyethylene): Better for fixed installations where flexibility is less critical. Good electrical properties, lower cost, but less flexible than EPR. Used in power distribution cables and fixed installations.
For mining mobile equipment, EPR is usually the better choice. For fixed underground power distribution, XLPE may be adequate and more economical.

Q6: What does “CM compound” sheath mean?

Answer: CM is a high-performance sheath compound used in premium mining cables (like PROTOLON and PROTOMONT). It’s typically a blend of chloroprene rubber and chlorosulfonated polyethylene (CSM/Hypalon), offering:

  • Superior resistance to oils, chemicals, and weather
  • Excellent flame retardance
  • High abrasion resistance
  • UV and ozone resistance
  • Better performance than standard CR (chloroprene) alone
CM sheath cables typically have longer service life in harsh mining environments.

Q7: How often should mining cables be replaced?

Answer: Replacement should be condition-based rather than time-based:

  • Immediate replacement if: Conductor exposure, severe sheath damage, insulation resistance < 1 MΩ·km, any damage in explosive atmosphere areas
  • Reeling cables: Typically 2-5 years in heavy use, longer in moderate use
  • Trailing cables: 5-10 years depending on conditions
  • Fixed installation cables: 10-20+ years with proper maintenance
Implement regular testing (quarterly insulation resistance, annual full electrical testing) to track cable condition and plan replacements proactively.

Q8: What’s the difference between Types W, G, and SHD-GC ANACONDA cables?

Answer: These are North American portable power cable types:

  • Type W: Hard-usage portable power cable, 2000V, flexible construction for mining
  • Type G: Mining power cable, 5-35kV, for trailing applications on mobile equipment
  • Type G-GC: Type G with ground check conductor for ground fault monitoring
  • SHD-GC: Shielded design with ground check, enhanced electrical safety
  • MP-GC: Mining power cable with ground check, typically for higher voltages
All are MSHA approved for US mining operations.

Q9: Can damaged cables be repaired?

Answer: It depends on the damage extent and location:

  • Minor sheath damage (surface only): Can be repaired with approved repair kits
  • Damaged conductors or insulation: Typically requires cable replacement
  • Damaged terminations: Can be re-terminated using proper procedures
  • Joints: Can be made using approved jointing kits (e.g., 3M Scotchcast)
Important: In explosive atmospheres (underground coal mines), regulations may prohibit field repairs. Always consult regulatory requirements and manufacturer guidelines. Any repair must maintain the cable’s original safety characteristics.

Q10: What is the significance of cable color coding?

Answer: Color coding serves several purposes:

  • Core Identification: Standard colors (e.g., Brown-Blue-Black for 3-phase + Green/Yellow for earth) allow proper connection
  • Voltage Identification: Different outer sheath colors may indicate voltage ratings
  • Application Identification: High-visibility colors (like TENAX LUMEN) improve safety
  • Standards Compliance: Different standards (VDE, BS, AS/NZS) may have different color schemes
Always verify core colors match the standard being used and follow proper termination diagrams.

Q11: What does “flexible” vs “highly flexible” actually mean in specifications?

Answer: Flexibility classifications relate to the cable’s conductor class and construction:

  • Class 5 (Flexible): Fine stranded conductors, suitable for most mobile applications
  • Class 6 (Highly Flexible): Extra fine stranding, for severe dynamic applications
  • Specific designs: Terms like “superflex” (MINEMASTER) or “ultra-flexible” (PROTOMONT V) indicate enhanced construction for extreme applications
The minimum bending radius is a practical indicator: the smaller the radius (relative to cable diameter), the more flexible the cable.

Q12: How do I calculate cable size needed for my equipment?

Answer: Cable sizing involves multiple factors:

  1. Load Current: Equipment full load amps + safety margin (typically 125%)
  2. Voltage Drop: Calculate voltage drop over cable length (typically limit to 4-5%)
  3. Ambient Temperature: Apply de-rating factors for high temperatures
  4. Installation Method: Apply de-rating for grouping, burial, etc.
  5. Short Circuit Rating: Verify cable can handle potential fault currents
Current carrying capacity tables are provided in the relevant standards (DIN VDE 0298-4 for VDE cables, within BS 6708 for BS cables, etc.). For critical applications, always consult a qualified electrical engineer.

Conclusion

This comprehensive guide has covered the complete range of mining cable models available for various applications in the global mining industry. From surface excavation to deep underground operations, from low voltage control circuits to high voltage power transmission, there are specialized cables engineered to meet every requirement.

Key Takeaways:

  • Application-Specific Selection: Different mining applications require different cable specifications – always match the cable to the specific application requirements
  • Standards Compliance: Ensure cables comply with relevant regional standards and have necessary mining authority approvals
  • Quality Matters: Premium cables from established manufacturers typically offer better long-term value through longer service life and enhanced safety
  • Proper Installation: Even the best cables will fail prematurely if not installed and maintained correctly
  • Safety First: In explosive atmospheres and high-risk mining environments, cable safety features are non-negotiable
  • Regular Maintenance: Implement systematic inspection and testing programs to ensure ongoing safety and reliability

At Anhui Feichun Special Cable Co., Ltd., we manufacture a complete range of mining cables meeting all major international standards. Our technical team has extensive experience in mining cable applications and can provide expert guidance on cable selection, installation, and maintenance for your specific project requirements.

Our Commitment:

We are committed to providing:

  • High-quality cables manufactured to international standards
  • Comprehensive technical support and engineering consultation
  • Competitive pricing with excellent value
  • Reliable delivery and global logistics support
  • After-sales service and technical assistance
  • Custom cable solutions for unique applications

Contact Our Expert Team

For detailed technical specifications, custom cable solutions, quotations, or expert consultation on mining cable selection for your specific application, please contact our experienced engineering and sales team:

📧 Technical Email: [email protected]
📞 International Sales: +86 13855123218

We provide comprehensive support including:

  • Cable selection and specification assistance
  • Technical drawings and certification documentation
  • Installation guidance and training
  • Testing services and quality assurance
  • After-sales technical support
  • Worldwide shipping and logistics coordination

References and Resources

This comprehensive guide is based on authoritative sources, industry standards, and manufacturer specifications:

Previous Article

DIN VDE 0250 vs BS 6708-6116 BCS 295: Comprehensive Mining Cable Standards Comparison

Next Article

What is a Type H07VVH6-F Cable F-1 PVC Flat Cable?

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注