600V 2TC-RB TRACAB® Kevlar®-Reinforced Crane Cable

600V Class 2 Ethylene Propylene Rubber Insulated, Polychloroprene Rubber Sheathed Cable with Kevlar® Aramid Fibre Braided Tensile Reinforcement — The TRACAB® System Cable Purpose-Built for Curtain, Carrier Drum, and Cableveyor Transport Methods on Port Gantry Cranes, Ship-to-Shore Unloaders, and Heavy-Duty Material Handling Equipment

Japanese-Standard Class 2 Dynamic Cable Engineering: Tin-Coated Annealed Copper Conductors Optimised for Class 2 Flexibility, EP Rubber Dielectric Insulation for Extreme Flex Life, Kevlar® Para-Aramid Braided Tensile Reinforcement Absorbing Dynamic Loads in Three Distinct Transport Architectures, Polychloroprene Rubber Outer Sheath for Oil, UV, and Saltwater Resistance, Coloured Tape Core Identification with Tracer Method for High Core Counts, Single-Core to 30-Core Configurations from 1.25 mm² to 325 mm², and Comprehensive TRACAB® Compatibility for Curtain Festoon, Motorised Carrier Drum, and Enclosed Cableveyor Track Systems

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
600V 2TC-RB TRACAB® Kevlar®-Reinforced Port Crane Cable — JIS C 3327, Class 2, Curtain, Carrier Drum & Cableveyor, EP Rubber Insulated, Polychloroprene Sheath | FeiChun Cable
JIS C 3327 — Class 2 TRACAB® Transport System Kevlar® Aramid Tensile Reinforcement Curtain · Carrier Drum · Cableveyor EP Rubber Insulated

600V 2TC-RB TRACAB® Kevlar®-Reinforced Crane Cable

600V Class 2 Ethylene Propylene Rubber Insulated, Polychloroprene Rubber Sheathed Cable with Kevlar® Aramid Fibre Braided Tensile Reinforcement — The TRACAB® System Cable Purpose-Built for Curtain, Carrier Drum, and Cableveyor Transport Methods on Port Gantry Cranes, Ship-to-Shore Unloaders, and Heavy-Duty Material Handling Equipment

Japanese-Standard Class 2 Dynamic Cable Engineering: Tin-Coated Annealed Copper Conductors Optimised for Class 2 Flexibility, EP Rubber Dielectric Insulation for Extreme Flex Life, Kevlar® Para-Aramid Braided Tensile Reinforcement Absorbing Dynamic Loads in Three Distinct Transport Architectures, Polychloroprene Rubber Outer Sheath for Oil, UV, and Saltwater Resistance, Coloured Tape Core Identification with Tracer Method for High Core Counts, Single-Core to 30-Core Configurations from 1.25 mm² to 325 mm², and Comprehensive TRACAB® Compatibility for Curtain Festoon, Motorised Carrier Drum, and Enclosed Cableveyor Track Systems

Anhui Feichun Special Cable Co., Ltd. Published April 2026 17 min technical read

Introduction: One Cable, Three Transport Systems

Port crane cable management is not a one-size-fits-all engineering problem. Different crane types, travel distances, operating speeds, and site conditions demand different cable transport architectures. A 200-metre STS crane boom may use a free-hanging curtain festoon. A 500-metre RTG crane runway may use motorised carrier drums. An enclosed overhead gantry in a dusty bulk terminal may use a cableveyor track system. Each architecture subjects the cable to a distinct combination of mechanical stresses—catenary tension, drum winding compression, guided track bending—and each demands a cable specifically engineered to survive those stresses for millions of operational cycles.

The 600V 2TC-RB is the TRACAB® product line cable designed to perform reliably across all three transport methods: curtain (festoon), carrier drum (reeling), and cableveyor (enclosed track). Manufactured to JIS C 3327 Class 2, this cable combines the proven EP rubber insulation and polychloroprene rubber sheathing platform with Class 2 conductor construction optimised for the specific bending profiles and fatigue modes encountered in each transport architecture. The Kevlar® para-aramid fibre braided tensile reinforcement provides the mechanical backbone that enables a single cable design to absorb the dynamic loads generated by catenary suspension, drum winding, and track-guided travel without transferring stress to the conductors or insulation system.

The result is a universal crane cable that simplifies procurement (one cable type across multiple crane systems), reduces spare part inventory, and ensures consistent, proven performance regardless of which transport method is used—or if the transport method changes during the crane’s operational life due to modifications or upgrades.

Critical Transport Method Matching

While the 2TC-RB is engineered for all three TRACAB® transport methods, each installation requires correct cable sizing for the specific transport architecture’s mechanical demands. Curtain systems impose catenary tensile loads proportional to cable weight and span length. Carrier drum systems impose compressive winding forces and multi-layer stacking pressure. Cableveyor systems impose guided bending at fixed radii with lateral guidance forces. Cable cross-section, core count, and overall diameter must be matched to the transport system’s rated capacity. Contact Feichun’s engineering team for project-specific transport method compatibility analysis.

Technical Specifications: JIS C 3327 Class 2

600V 2TC-RB TRACAB® Kevlar®-Reinforced Cable — Key Specifications
ParameterSpecification
Standard ComplianceJIS C 3327 Class 2 (Japanese Industrial Standard for cabtyre cables). Equivalent: Feichun FC-2TC-RB-K™ TRACAB Series.
Voltage Rating600V. Test voltage: 3,000V / 1 min.
Cable Designation600V 2TC-RB — low voltage power, Class 2, EP rubber insulated, polychloroprene rubber sheathed.
Conductor MaterialTin-coated annealed copper strand wire. Superior corrosion resistance in saltwater marine environments.
Conductor ClassClass 2 per IEC 60228 / JIS C 3327. Optimised stranding for combined tensile, compressive, and guided-bend fatigue resistance.
Insulation MaterialEthylene propylene rubber (EP rubber). Excellent dielectric strength, heat resistance, and flexibility retention.
Tensile ReinforcementKevlar® para-aramid fibre braided layer. Proprietary helical braid pattern. 5× stronger than steel per unit weight.
Outer SheathPolychloroprene rubber (CR rubber). Oil-resistant, flame-retardant, UV-stable, saltwater-resistant.
Core CountSingle core (1.25–325 mm²); 2–4 cores (1.25–200 mm²); 5–30 cores (1.25–5.5 mm²).
TRACAB® CompatibilityCurtain (festoon), Carrier drum (reeling), Cableveyor (enclosed track).
Temperature Range−30°C to +80°C (continuous operation). Short-circuit: 200°C.
Bending Radius (Dynamic)6× OD minimum for curtain/cableveyor; 8× OD for carrier drum applications.
Bending Radius (Fixed)4× OD minimum for static installations.
Flex Life (Typical)>1,000,000 cycles at rated bending radius (laboratory conditions, 25°C).

TRACAB® Transport Architecture: Curtain, Carrier Drum & Cableveyor

Curtain (Festoon) System

In a curtain system, the cable hangs in free catenary loops between trolley-mounted carrier saddles suspended from an overhead rail. As the crane trolley travels, the cable loops gather and spread—resembling a sliding curtain. The cable must support its own weight in the catenary span, absorb dynamic acceleration and deceleration forces from trolley movement, and withstand millions of gathering/spreading cycles. The primary stress mode is tensile loading combined with cyclic bending. The Kevlar® tensile reinforcement absorbs the self-weight catenary load and dynamic forces, while the EP rubber insulation and Class 2 conductor construction withstand the repeated bending at carrier saddle contact points.

Carrier Drum (Reeling) System

In a carrier drum system, the cable winds onto and unwinds from a motorised reeling drum as the crane travels. The drum is typically mounted on the crane structure, and the cable feeds from a fixed anchor point through a level-wind mechanism onto the rotating drum. The cable must withstand compressive winding forces (especially in multi-layer winding where upper layers press on lower layers), controlled tensile loading (from the cable’s weight plus the level-wind tension), and repeated bending at the drum surface radius. The 2TC-RB’s Class 2 construction is particularly advantageous here: the conductor stranding provides superior resistance to the compressive deformation experienced during tight drum winding, and the Kevlar® layer prevents cable elongation that would cause uneven drum packing.

Cableveyor (Enclosed Track) System

A cableveyor system guides the cable through an enclosed C-shaped or U-shaped track (also called an energy chain or cable track). The cable bends around the track’s fixed bend radius as the moving section of track travels relative to the fixed section. The cable must withstand guided bending at a fixed, known radius (typically 200–600 mm depending on track size), lateral guidance forces from contact with the track sidewalls, and surface abrasion from sliding contact with the track interior. The polychloroprene sheath’s excellent abrasion resistance is critical in this application, and the Kevlar® reinforcement prevents cable stretching that would cause slack accumulation and jamming within the track.

One Cable, Three Systems — Why This Matters

Many cable manufacturers offer separate product lines for festoon, reeling, and cableveyor applications—each with different conductor classes, insulation types, and sheath materials. This forces specifiers to manage multiple cable types, stock multiple spare inventory items, and risk incompatibility when transport systems are modified. The 2TC-RB TRACAB® cable’s Class 2 construction with Kevlar® reinforcement is validated for all three transport methods, enabling standardisation across the entire crane fleet. A single cable type serves every application, simplifying procurement, reducing inventory cost, and ensuring field interchangeability between transport systems.

Class 2 Conductor Construction: The Flexibility Difference

The 2TC-RB is designated Class 2 per JIS C 3327 and IEC 60228, which specifies a stranded conductor with moderate flexibility. Class 2 conductors use fewer, thicker strands than Class 5 (very flexible) conductors, but more strands than Class 1 (solid) conductors. This intermediate construction is deliberately engineered for the specific mechanical demands of TRACAB® transport systems.

The Class 2 advantage lies in its balance between flexibility, compressive resistance, and tensile stability. In curtain (festoon) applications, Class 2 provides sufficient flexibility for the catenary bending cycles while offering greater resistance to permanent elongation under sustained tensile load than extremely fine-stranded Class 5 construction. In carrier drum (reeling) applications, Class 2’s thicker strands resist the compressive deformation that occurs when cable layers stack on the drum—fine-stranded Class 5 conductors can flatten and deform under multi-layer winding pressure, reducing cross-sectional area and increasing resistance. In cableveyor (track) applications, Class 2 provides the guided-bending flexibility required at fixed track radii while maintaining conductor geometry under the lateral forces from track sidewall contact.

The tin-coated annealed copper strand wire ensures that the Class 2 construction retains its mechanical properties throughout the cable’s service life. The annealing process eliminates work hardening from the wire drawing process, maximising ductility and preventing the gradual embrittlement that would cause strand breakage under repeated bending. The tin coating prevents inter-strand corrosion in the humid, salt-spray-laden port environment—corrosion between strands can effectively bond adjacent strands together, converting a multi-strand conductor into a quasi-solid conductor with dramatically reduced flexibility.

Class 2 vs. Class 5: When to Use Each

The 2TC Light (2PNCT) cable uses Class 3 general flexibility construction, while the 2TC-RB uses Class 2. The choice depends on the primary application: Class 5 is preferred for applications where maximum flexibility and minimum bending radius are the priority (tight-radius sheaves, small-diameter reeling drums). Class 2 is preferred for TRACAB® transport systems where the cable must resist both bending fatigue and compressive/tensile mechanical loading. For most port crane curtain, carrier drum, and cableveyor installations, Class 2 provides the optimal balance of properties.

Cable Construction: Layer-by-Layer Engineering

The 2TC-RB cable comprises six functional zones, each engineered for the combined mechanical demands of curtain, carrier drum, and cableveyor transport:

Layer 1 — Conductor: Tin-coated annealed copper strand wire, Class 2 stranding. Strand configurations range from 50/0.18 (1.25 mm²) to 37/55/0.45 (325 mm²). The Class 2 stranding provides the balance of flexibility and compressive resistance required for multi-method transport compatibility.

Layer 2 — Separator: A thin separator tape wraps each conductor, preventing the EP rubber insulation from bonding to the copper surface. Free conductor movement within the insulation tube is essential for preventing insulation cracking during the repeated bending cycles in all three transport methods.

Layer 3 — EP Rubber Insulation: Ethylene propylene rubber provides the primary dielectric barrier. Insulation thickness ranges from 0.8 mm (small conductors) to 2.5 mm (large conductors). EP rubber’s superior flexibility retention at low temperatures (−30°C), ozone crack resistance, and ability to maintain dielectric strength after millions of flex cycles make it the ideal insulation for dynamic crane cables.

Layer 4 — Coloured Tape & Fillers: Each insulated core is wrapped with a coloured identification tape per the wire core identification scheme. In multi-core cables, non-hygroscopic fillers occupy the interstices between cores. A binder tape wraps the assembled core bundle.

Layer 5 — Kevlar® Aramid Braided Tensile Layer: The proprietary helical-braided aramid reinforcement layer provides the structural backbone. With tensile strength of approximately 3,620 MPa at 1.44 g/cm³ density, the Kevlar® braid absorbs catenary loads (curtain), winding tension (carrier drum), and track tension (cableveyor) while protecting internal cable components from mechanical stress.

Layer 6 — Polychloroprene Rubber Sheath: The outer protective sheath provides environmental defence against oil, UV, saltwater, abrasion, and flame. Sheath thickness ranges from 1.6 mm (small single-core) to 5.5 mm (4-core 200 mm²). The polychloroprene sheath’s abrasion resistance is particularly important for cableveyor applications.

Kevlar® Aramid Braided Tensile Reinforcement

The Kevlar® para-aramid fibre braided tensile reinforcement is the engineering feature that enables the 2TC-RB to function across all three TRACAB® transport methods. Without this reinforcement, the cable’s conductors would bear the full mechanical load—an untenable situation resulting in progressive conductor fatigue and premature failure.

In curtain (festoon) systems, the Kevlar® braid absorbs the catenary self-weight load and dynamic forces. A 4-core 200 mm² cable weighing 11,440 kg/km generates over 1,100 kg of self-weight tension in a 100-metre span—a load the Kevlar® braid handles effortlessly but that would stretch and fatigue bare copper conductors within weeks.

In carrier drum (reeling) systems, the Kevlar® braid maintains cable dimensional stability under winding compression. The aramid braid resists radial compression, preventing the cable from flattening and ensuring consistent unwinding behaviour throughout the drum’s layer capacity.

In cableveyor (track) systems, the Kevlar® braid prevents cable elongation under the track’s pulling forces. The aramid braid’s low elongation at break (~3.6%) limits cable stretch to negligible levels, maintaining proper cable tension throughout the track length and preventing slack accumulation that could cause jamming.

EP Rubber Insulation & Polychloroprene Sheath

EP Rubber Insulation provides dielectric strength of 20–30 kV/mm, giving a safety margin of 25–100× the 600V rating. EP rubber maintains flexibility at −30°C, resists ozone cracking, and withstands millions of flex cycles without micro-cracking. Minimum insulation resistance ranges from 200 MΩ·km to 500 MΩ·km at 20°C.

Polychloroprene Rubber Sheath provides simultaneous oil resistance, flame retardancy, UV stability, ozone resistance, saltwater impermeability, and abrasion resistance. For the 2TC-RB, the polychloroprene sheath’s abrasion resistance is a critical performance parameter for cableveyor track systems where the cable surface is in continuous sliding contact with the track interior. The material is inherently self-extinguishing—a safety requirement for crane cable trays.

Wire Core Identification & Tracer Method

Wire Core Colour Identification — 2TC-RB per JIS C 3327
Core CountColour AssignmentIdentification Method
2 coreBlack, WhiteStandard colour coding
3 coreBlack, White, RedStandard colour coding
4 coreBlack, White, Red, GreenStandard colour coding
5+ coreBlack, White, Red, Black, Black…Tracer method

For cables with 5 or more cores, the 2TC-RB uses the tracer method of core identification. The first three cores are identified by distinct colours (Black, White, Red), and all subsequent cores are Black with a coloured tracer stripe or tape to distinguish each core from the others. This method ensures clear, reliable core identification even in cables with 20 or 30 cores.

Selecting Configurations for TRACAB® Transport

For STS crane main hoist drives via curtain festoon: 3-core or 4-core, 38–100 mm². For RTG carrier drum reeling: 3-core 22–60 mm². For cableveyor systems on gantry cranes: 4-core 14–38 mm² for power, 12–30 core 1.25–2 mm² for control. Contact Feichun for project-specific configuration recommendations.

Dimensional & Electrical Data: Single Core (1.25–325 mm²)

2TC-RB — Single Core, 1.25 to 325 mm²
mm²ConductorCond. ⌀ (mm)EP Ins. (mm)CR Sheath (mm)Overall ⌀ (mm)Max. ⌀ (mm)Weight (kg/km)Max. RDC 20°C (Ω/km)Test V (V/1 min)Min. IR 20°C (MΩ·km)
1.2550/0.181.50.81.67.08.06515.53000500
237/0.261.80.81.67.58.5759.913000500
3.545/0.322.50.81.68.09.01005.383000400
5.570/0.323.11.01.79.510.51353.463000400
850/0.453.71.01.710.011.01652.453000400
1488/0.454.91.01.811.512.52401.393000300
227/20/0.457.01.22.014.515.53750.8923000300
307/27/0.458.11.22.015.516.54700.6613000300
387/34/0.459.11.22.116.517.55650.5253000200
5019/16/0.4510.01.52.218.519.57050.4113000200
6019/20/0.4511.21.52.320218500.3293000200
8019/27/0.4513.02.02.5232411500.2433000300
10019/34/0.4514.72.02.6252614000.1933000200
12519/42/0.4516.32.02.7272816800.1563000200
15027/34/0.4517.72.02.8293019000.1363000200
20037/34/0.4520.02.53.0333425600.09933000200
25037/42/0.4522.02.53.2353730900.08033000200
32537/55/0.4525.42.53.4394139400.06143000200

Dimensional & Electrical Data: Multi-Core 2–4 Cores (1.25–200 mm²)

2TC-RB — 2 Core, 1.25 to 200 mm²
mm²ConductorCond. ⌀EP Ins.CR SheathOverall ⌀Max. ⌀WeightMax. RDCTest VMin. IR
1.2550/0.181.50.81.811.012.013516.03000500
237/0.261.80.81.811.512.515510.23000500
3.545/0.322.50.81.913.014.02155.543000400
5.570/0.323.11.02.015.516.53053.633000400
850/0.453.71.02.218.019.04152.573000400
1488/0.454.91.02.421226051.463000300
227/20/0.457.01.22.727289600.9373000300
307/27/0.458.11.22.8293012000.6943000300
387/34/0.459.11.23.0313314500.5513000200
5019/16/0.4510.01.53.2353718100.4323000200
6019/20/0.4511.21.53.4384021800.3453000200
8019/27/0.4513.02.03.7444629400.2553000300
10019/34/0.4514.72.04.0485135900.2033000200
12519/42/0.4516.32.04.2525442800.1643000200
15027/34/0.4517.72.04.4555848500.1433000200
20037/34/0.4520.02.54.8636665100.1043000200
2TC-RB — 3 Core, 1.25 to 200 mm²
mm²ConductorCond. ⌀EP Ins.CR SheathOverall ⌀Max. ⌀WeightMax. RDCTest VMin. IR
1.2550/0.181.50.81.811.512.515516.03000500
237/0.261.80.81.812.013.018510.23000500
3.545/0.322.50.81.913.514.52655.543000400
5.570/0.323.11.02.116.517.53903.633000400
850/0.453.71.02.319.0205252.573000400
1488/0.454.91.02.422237751.463000300
227/20/0.457.01.22.8283012500.9373000300
307/27/0.458.11.23.0313315900.6943000300
387/34/0.459.11.23.1343519100.5513000200
5019/16/0.4510.01.53.3373923900.4323000200
6019/20/0.4511.21.53.5414329000.3453000200
8019/27/0.4513.02.03.9475039300.2553000300
10019/34/0.4514.72.04.2525448100.2033000200
12519/42/0.4516.32.04.4565857500.1643000200
15027/34/0.4517.72.04.6596265200.1433000200
20037/34/0.4520.02.55.1687188300.1043000200
2TC-RB — 4 Core, 1.25 to 200 mm²
mm²ConductorCond. ⌀EP Ins.CR SheathOverall ⌀Max. ⌀WeightMax. RDCTest VMin. IR
1.2550/0.181.50.81.912.513.519016.03000500
237/0.261.80.81.913.014.023010.23000500
3.545/0.322.50.82.015.016.03305.543000400
5.570/0.323.11.02.218.019.04853.633000400
850/0.453.71.02.421226602.573000400
1488/0.454.91.02.625269951.463000300
227/20/0.457.01.23.0313315900.9373000300
307/27/0.458.11.23.1343620200.6943000300
387/34/0.459.11.23.3373924500.5513000200
5019/16/0.4510.01.53.6424430800.4323000200
6019/20/0.4511.21.53.8454737400.3453000200
8019/27/0.4513.02.04.2535550800.2553000300
10019/34/0.4514.72.04.5576062100.2033000200
12519/42/0.4516.32.04.8626574600.1643000200
15027/34/0.4517.72.05.0666984600.1433000200
20037/34/0.4520.02.55.57579114400.1043000200

Dimensional & Electrical Data: Multi-Core 5–30 Cores (1.25–5.5 mm²)

2TC-RB — 1.25 mm² and 2 mm², 5 to 30 Core
Coresmm²ConductorCond. ⌀EP Ins.CR SheathOverall ⌀Max. ⌀WeightMax. RDCTest VMin. IR
51.2550/0.181.50.81.913.514.522016.03000500
61.2550/0.181.50.82.014.515.526516.03000500
71.2550/0.181.50.82.115.516.530516.03000500
81.2550/0.181.50.82.116.517.534516.03000500
101.2550/0.181.50.82.218.019.041516.33000500
121.2550/0.181.50.82.218.519.545516.33000500
161.2550/0.181.50.82.4212258516.33000500
201.2550/0.181.50.82.5232471016.33000500
301.2550/0.181.50.82.72728101016.33000500
5237/0.261.80.82.014.515.527510.23000500
6237/0.261.80.82.015.516.532010.23000500
7237/0.261.80.82.116.517.537510.23000500
8237/0.261.80.82.218.019.043010.23000500
10237/0.261.80.82.319.52152010.43000500
12237/0.261.80.82.3202158010.43000500
16237/0.261.80.82.4222473010.43000500
20237/0.261.80.82.6252690510.43000500
30237/0.261.80.82.82931128010.43000500
2TC-RB — 3.5 mm² and 5.5 mm², 5 to 30 Core
Coresmm²ConductorCond. ⌀EP Ins.CR SheathOverall ⌀Max. ⌀WeightMax. RDCTest VMin. IR
53.545/0.322.50.82.116.517.54005.543000400
63.545/0.322.50.82.218.019.04755.543000400
73.545/0.322.50.82.319.5215555.543000400
83.545/0.322.50.82.421226355.543000400
103.545/0.322.50.82.523247755.653000400
123.545/0.322.50.82.524258705.653000400
163.545/0.322.50.82.7262811205.653000400
203.545/0.322.50.82.8293013705.653000400
303.545/0.322.50.83.1343619905.653000400
55.570/0.323.11.02.319.5215903.633000400
65.570/0.323.11.02.422237053.633000400
75.570/0.323.11.02.523248203.633000400
85.570/0.323.11.02.625269403.633000400
105.570/0.323.11.02.7272911403.633000400
125.570/0.323.11.02.8283013003.633000400
165.570/0.323.11.03.0323316703.633000400
205.570/0.323.11.03.2353720703.633000400
305.570/0.323.11.03.6424430003.633000400

Application Guide: Port Cranes & Material Handling Systems

STS Gantry Cranes — Curtain Festoon Systems

Super Post-Panamax STS cranes with 50–140 metre boom lengths are the primary curtain festoon application. The 2TC-RB cable hangs in catenary loops between trolley carriers. Cable selection: 3-core or 4-core 38–100 mm² for main hoist and trolley drives, 20–30 core 1.25–2 mm² for control and signalling. The Kevlar® reinforcement absorbs the substantial catenary loads generated by the heaviest cable sizes—a 4-core 200 mm² cable at 11,440 kg/km generates over 1 tonne of self-weight tension in a 100-metre span.

RTG Cranes — Carrier Drum Reeling Systems

Rubber-tyred gantry cranes in container yards use motorised carrier drums to manage the power cable as the crane travels 300–600 metres along container storage rows. The 2TC-RB’s Class 2 construction resists the compressive flattening that occurs during multi-layer drum winding, while the Kevlar® layer maintains consistent cable tension during unwinding. Typical selection: 3-core 22–60 mm² for main power supply.

Overhead Gantry Cranes — Cableveyor Track Systems

Indoor and outdoor overhead gantry cranes in bulk terminals, steel mills, and manufacturing facilities use cableveyor (energy chain) track systems. The enclosed track protects cables from environmental contamination while providing guided, controlled cable movement. The 2TC-RB’s polychloroprene sheath withstands continuous track contact abrasion, and the Class 2 conductor construction provides reliable performance at the track’s fixed bend radius.

Ship Unloaders — Mixed Transport Systems

Large ship unloaders often combine multiple transport methods: a curtain festoon for the trolley travel, a carrier drum for the gantry travel, and a cableveyor for the shuttle mechanism. The 2TC-RB’s TRACAB® compatibility across all three methods enables standardisation of the entire cable inventory for the unloader.

Extended Product Range

The 2TC-RB offers the widest configuration range in the TRACAB® cable family: single-core up to 325 mm², multi-core (2–4 core) up to 200 mm², and control cables (5–30 core) up to 5.5 mm². This extended range exceeds the ranges available in the 2TC Light and 2TC Light-SB series, reflecting the higher power and control demands of the large crane installations that typically use TRACAB® transport systems.

2TC-RB Class 2 vs. 2TC Light Class 3: Selecting the Right Class

2TC-RB (Class 2) vs. 2TC Light (Class 3) — Engineering Comparison
Feature2TC-RB (Class 2, TRACAB®)2TC Light (Class 3)
Conductor ClassClass 2 — moderate flexibilityClass 3 — general flexibility
Transport MethodsCurtain + Carrier Drum + CableveyorCurtain (festoon) primary
Compressive ResistanceSuperiorModerate
Tensile StabilitySuperiorModerate
Max. Multi-Core Size (4-core)200 mm²100 mm²
5–30 Core Size Range1.25–5.5 mm²1.25–3.5 mm²
Core ID (5+ core)Tracer method6-colour combination
Ideal ApplicationMulti-method TRACAB® systems, large cranesGeneral-purpose festoon, lighter-duty cranes
Carrier Drum SuitabilityExcellentAcceptable with limitations
Cableveyor SuitabilityExcellentAcceptable with limitations

Installation Best Practices for Each Transport Method

Curtain (Festoon) Installation

Size carrier trolley saddles for the cable’s maximum outer diameter with 10–15% clearance. Maintain the minimum dynamic bending radius of 6× OD at all guide points and end terminations. Festoon end clamps must include strain relief that transfers load to the Kevlar® braid rather than the conductors. Inspect carrier saddles every 6 months for wear.

Carrier Drum (Reeling) Installation

Drum diameter must be at least 12× the cable OD for power cables and 10× OD for control cables. Wind the cable under consistent tension (1–2% of rated breaking strength) using a level-wind mechanism. For multi-layer winding, verify the cable can withstand the cumulative compressive force of all planned layers—consult Feichun for layer-pressure calculations.

Cableveyor (Track) Installation

The track’s internal bend radius must meet or exceed 6× OD. Cable fill ratio within the track should not exceed 80% of internal cross-sectional area. Use separator bars between power and control cables. Verify polychloroprene sheath compatibility with track material (polychloroprene is compatible with standard nylon and UHMWPE track materials).

Universal Requirements

All power cable terminations should use crimped compression lugs with insulation boots. Control cable terminations should use industrial connectors with IP65 minimum protection. All termination points must include strain relief devices transferring load to the Kevlar® braid. Perform insulation resistance testing annually using a 500V megger.

Technical FAQ

What does “TRACAB” mean?

TRACAB® is a product line designation indicating that the cable has been specifically engineered and validated for use in three transport architectures: curtain (festoon), carrier drum (reeling), and cableveyor (enclosed track). The designation signifies that the cable’s construction has been optimised for the combined mechanical demands of all three systems.

Can the 2TC-RB be used with VFD-driven motors?

The 2TC-RB does not include an EMI shield. For VFD output cables, the shielded 2TC Light-SB (2PNCT-SB) variant should be used instead. The 2TC-RB is suitable for direct-on-line motor power, control circuits, lighting, and applications where VFD-generated EMI is not a concern.

Why does the 2TC-RB offer 5.5 mm² in the 5–30 core range while the 2TC Light only goes to 3.5 mm²?

The 2TC-RB’s TRACAB® target applications—large STS cranes, ship unloaders, and heavy material handling systems—often require higher-current control and auxiliary circuits. Motor brake circuits, heating elements, and high-power control relays on large cranes may require 5.5 mm² conductors in multi-core control cables.

What is the maximum carrier drum travel speed?

The cable is validated for carrier drum applications at travel speeds up to 250 m/min (4.2 m/s). Higher speeds may be possible depending on the specific cable size, drum diameter, and tension management system. Contact Feichun for high-speed reeling applications.

Is the 4-core 200 mm² cable practical for festoon systems?

The 4-core 200 mm² cable weighs 11,440 kg/km with 75 mm overall diameter. The Kevlar® reinforcement handles the self-weight load, but the festoon carrier system must be designed for this weight—requiring heavy-duty trolley frames, reinforced overhead rails, and shorter span lengths. For spans exceeding 15–20 metres, intermediate support carriers are essential. Carrier drum reeling is often more practical for the heaviest cable sizes.

How does the cable perform in extreme cold?

The 2TC-RB is rated for continuous operation at −30°C. For arctic port installations (−40°C and below), Feichun offers a special cold-climate formulation. Contact the engineering team for extreme cold specifications.

References & Standards

  1. JIS C 3327, 600 V EP Rubber Insulated Polychloroprene Sheathed Cabtyre Cables — Japanese Industrial Standard.
  2. JIS C 3005, Test methods for rubber and plastics insulated wires and cables.
  3. IEC 60228, Conductors of insulated cables — Classification and construction requirements (Class 2).
  4. DuPont™ Kevlar® Technical Guide, Properties and Applications of Kevlar® Aramid Fibre.
  5. IEC 60811-1-1, Insulating and sheathing materials of electric and optical cables — Common test methods.
  6. DIN ISO 4649, Rubber — Determination of abrasion resistance using a rotating cylindrical drum device.
  7. FEM 1.001, Rules for the Design of Hoisting Appliances.
  8. ISO 9001:2015, Quality management systems — Requirements.
  9. ASTM D885, Standard Test Methods for Tire Cords and Industrial Filament Yarns (aramid tensile testing).

Contact Anhui Feichun Special Cable Co., Ltd. — TRACAB® Transport System Cable Specialists

Technical Specifications & Transport System Engineering[email protected]
TRACAB® Cable Procurement & Project Quotations[email protected]
24/7 Emergency Technical Support+86 138 5608 5607
Technical WhatsApp & WeChat+86 138 5512 3218

This technical guide covers Feichun’s proprietary Kevlar®-reinforced equivalent to the Japanese JIS C 3327 Class 2 600V 2TC-RB TRACAB® cable series, incorporating tin-coated annealed copper Class 2 conductors, EP rubber insulation, Kevlar® para-aramid fibre braided tensile reinforcement layer, polychloroprene rubber outer sheath, coloured tape core identification with tracer method for high core counts, and comprehensive dimensional and electrical specifications for single-core (1.25–325 mm²), multi-core 2–4 core (1.25–200 mm²), and multi-core 5–30 core (1.25–5.5 mm²) configurations. Engineered for curtain (festoon), carrier drum (reeling), and cableveyor (enclosed track) transport systems on port gantry cranes, STS ship unloaders, RTG container cranes, and heavy-duty material handling equipment. TRACAB® is a registered trademark. Kevlar® is a registered trademark of DuPont de Nemours, Inc. All specifications are approximate and subject to manufacturing tolerances.

© 2026 Anhui Feichun Special Cable Co., Ltd. All rights reserved.

Previous Article

6600V 3PNCT Kevlar®-Reinforced High Voltage Crane Cable

Next Article

JIS C 3327 Cable Code Designation

Write a Comment