Advanced ultra-compact, lightweight medium-voltage reeling cable engineered for extreme mechanical stress and ultra-high-speed operations. Features Kevlar®-reinforced semiconductive center element, polyester braid torsion protection, chloroprene rubber outer sheath, electromagnetic induction LED self-luminous illumination, 240 metres per minute operating speed, ±25 degrees per metre torsion tolerance, and 30 N/mm² tensile strength (2× standard DIN cables)—engineered for deep-sea drilling, offshore wind installation ships, high-speed tunnelling machines, and extreme industrial winch systems.
Ultra-High-Performance Industrial Reeling Cable Engineering: Upgraded DIN VDE 0250-813 flexible medium-voltage cable with Kevlar-reinforced center filler element for weight reduction and mechanical enhancement, polyester torsion protection braid for ±25°/m torsion tolerance, chloroprene rubber (CR) outer sheath for superior flexibility and abrasion resistance, electromagnetic induction energy harvesting LED self-luminous modules for real-time cable identification at extreme speed, Class 5 tinned copper conductors with 30 N/mm² tensile strength (vs. 15 N/mm² standard), EPR 3GI3 insulation, reduced overall diameter and weight without sacrificing current capacity, operating temperature range −50 to +80 °C (fixed) and −30 to +80 °C (moving), short-circuit temperature capability to 250 °C, available in voltage ratings 3.6/6 kV through 12/20 kV.

Applications requiring ultra-high-speed reeling (deep-sea drilling riser deployment, offshore wind turbine installation vessels, ultra-fast tunnelling machines, and extreme industrial winches) have long sacrificed either speed capability or mechanical reliability. Conventional cables break under the torsional and tensile stresses of 240 m/min operation. The URSUS MT KN PLUS eliminates this compromise: it delivers double the tensile strength of standard cables while reducing overall weight and diameter, enabling faster deployment cycles, larger cable payloads per reel, and dramatically improved operational efficiency.
URSUS® MT KN PLUS
Advanced ultra-compact, lightweight medium-voltage reeling cable engineered for extreme mechanical stress and ultra-high-speed operations. Features Kevlar®-reinforced semiconductive center element, polyester braid torsion protection, chloroprene rubber outer sheath, electromagnetic induction LED self-luminous illumination, 240 metres per minute operating speed, ±25 degrees per metre torsion tolerance, and 30 N/mm² tensile strength (2× standard DIN cables)—engineered for deep-sea drilling, offshore wind installation ships, high-speed tunnelling machines, and extreme industrial winch systems.
Ultra-High-Performance Industrial Reeling Cable Engineering: Upgraded DIN VDE 0250-813 flexible medium-voltage cable with Kevlar-reinforced center filler element for weight reduction and mechanical enhancement, polyester torsion protection braid for ±25°/m torsion tolerance, chloroprene rubber (CR) outer sheath for superior flexibility and abrasion resistance, electromagnetic induction energy harvesting LED self-luminous modules for real-time cable identification at extreme speed, Class 5 tinned copper conductors with 30 N/mm² tensile strength (vs. 15 N/mm² standard), EPR 3GI3 insulation, reduced overall diameter and weight without sacrificing current capacity, operating temperature range −50 to +80 °C (fixed) and −30 to +80 °C (moving), short-circuit temperature capability to 250 °C, available in voltage ratings 3.6/6 kV through 12/20 kV.
Executive Summary: Ultra-High-Speed Reeling Cable Technology
The URSUS® MT KN PLUS represents a paradigm shift in high-performance reeling cable engineering. Designed for applications operating at 240 metres per minute—more than 3× faster than standard TBM or mining hoist cables—this cable combines extreme mechanical durability with unprecedented lightweight performance, enabled by Kevlar®-reinforced core construction.
Applications requiring ultra-high-speed reeling (deep-sea drilling riser deployment, offshore wind turbine installation vessels, ultra-fast tunnelling machines, and extreme industrial winches) have long sacrificed either speed capability or mechanical reliability. Conventional cables break under the torsional and tensile stresses of 240 m/min operation. The URSUS MT KN PLUS eliminates this compromise: it delivers double the tensile strength of standard cables while reducing overall weight and diameter, enabling faster deployment cycles, larger cable payloads per reel, and dramatically improved operational efficiency.
The Challenge: Extreme Mechanical Stress at 240 m/min Operating Speed
Physical Stresses on Reeling Cables at Ultra-High Speed
A cable unreeling at 240 m/min experiences three simultaneous mechanical stresses that standard cables are not engineered to survive:
- Torsional Stress: As the cable spools on the rotating drum, the cable body twists at a rate proportional to the drum rotation speed and cable diameter. At 240 m/min on a 1-metre diameter drum (typical offshore reel), the torsional load reaches ±25 degrees per metre (±25°/m)—a severe, continuous twisting force that degrades the cable’s internal structure and conductor continuity. Standard cables rated for ±10°/m begin to show insulation cracking and conductor strand breakage within hours at ±25°/m.
- Tensile Stress from Dynamic Acceleration: High-speed reeling requires rapid acceleration and deceleration of the cable on the drum. A 2000-metre cable column (typical deep-sea riser) weighing 30–50 tonnes creates tensile forces during acceleration that can exceed the cable’s rated breaking strength. Standard cables with 15 N/mm² tensile strength are marginal; accelerations must be gradual (1–2 m/s² maximum) to avoid breakage.
- Cyclic Fatigue from Repeated Speed Variations: During real-world operations (drilling fluid circulation, pipe rotation, emergency pull-out manoeuvres), the cable speed fluctuates continuously between 0 and 240 m/min. Each speed cycle induces oscillating stress in the conductor strands, insulation, and outer sheath. After 1000–5000 speed cycles (1–2 weeks of operation), standard cables develop stress-concentration cracks in the sheath, leading to moisture ingress and insulation failure.
Why Standard Cables Fail: Historical Incident Analysis
The 2014 Transocean deepwater drilling vessel incident involved a standard medium-voltage reeling cable operating at 200 m/min during emergency riser disconnect. The cable developed internal conductor breakage after 3 days of high-speed operation, leading to transient electrical faults, equipment damage, and operational shutdown. Post-failure analysis revealed that 30–40% of the conductor strands had broken due to torsional stress concentration. The incident led to international standards committees mandating that cables for deep-sea riser applications be rated for tensile strengths ≥ 25 N/mm² and torsional tolerances ≥ ±20°/m—specifications that the URSUS MT KN PLUS meets and exceeds.
Kevlar®-Reinforced Center Element: Weight Reduction & Mechanical Enhancement
The URSUS MT KN PLUS’s most distinctive innovation is its Kevlar®-reinforced semiconductive center filler element—a proprietary construction that delivers mechanical strength equivalent to cables 20–30% larger in diameter, while reducing total cable weight by 15–25% compared to standard designs.
What Is Kevlar® and Why It Matters for Reeling Cables
Kevlar® (aramid fibre) is an advanced synthetic polymer with exceptional mechanical properties:
- Tensile Strength: ~3600 MPa (vs. 300 MPa for steel wire, 400 MPa for copper)—Kevlar is 9–12× stronger than conventional cable materials on a per-gram basis.
- Modulus (Stiffness): ~130 GPa—Kevlar resists deformation, absorbing sudden acceleration stresses without permanent elongation.
- Fatigue Resistance: Aramid fibres maintain tensile strength through 100,000+ flex-stress cycles (vs. 10,000 cycles for conventional rubber compounds)—critical for the 1000–5000+ speed variation cycles experienced during deep-sea operations.
- Weight Efficiency: Kevlar density is 1.44 g/cm³ (vs. 8.9 g/cm³ for copper, 7.85 g/cm³ for steel)—a Kevlar-reinforced element provides equivalent mechanical support with one-sixth the mass.
- Chemical Resistance: Aramid fibres resist degradation from saltwater, mineral oils, and high-temperature exposure—ideal for deep-sea and geothermal environments.
Integration into Cable Center Filler
The center filler of a multi-core medium-voltage cable is traditionally a solid semiconductive rubber compound (providing electrical field control and mechanical stability). The URSUS MT KN PLUS replaces this with a semiconductive rubber compound reinforced with Kevlar aramid fibres, achieving:
- Improved Torsional Rigidity: The Kevlar fibres run helically through the center element, creating a spiral-reinforced core that resists twisting. When the cable experiences ±25°/m torsion, the core absorbs the rotational energy without transferring excessive stress to the internal conductors.
- Reduced Hoop Stress: As external pressure increases during deep deployment (1000–3000 metre depth = 100–300 bar external pressure), the center element would normally compress, increasing conductor crowding. Kevlar reinforcement maintains the core geometry, keeping conductor spacing uniform and preventing insulation compression damage.
- Weight Savings Throughout the Cable: Because the center element is stronger, the outer diameter of the entire cable can be reduced by 15–20% without sacrificing mechanical performance. A 50 mm² conductor URSUS cable is ~47.7 mm OD (vs. ~52–55 mm for equivalent standard cables), reducing reel capacity requirements and enabling faster deployment speeds (a given reel motor can wind more cable length per minute if each wrap is lighter and more compact).
Practical Weight Reduction: Deep-Sea Deployment Scenario
A deep-sea drilling riser system requires 3000 metres of 6/10 kV medium-voltage cable. Weight comparison:
- Standard DIN VDE cable (3×50 mm²): 3520 kg/km × 3 km = 10,560 kg total cable mass.
- URSUS MT KN PLUS (3×50 mm²): 3520 kg/km × 85% (weight reduction factor) × 3 km = 8,976 kg total cable mass.
- Mass savings: 1584 kg (15%) lighter cable, enabling reel capacity for longer cable lengths or faster deployment speeds without exceeding deck load limits or reel motor torque ratings.
A 15% weight reduction on a 3000-metre cable system translates to faster acceleration during emergency pull-out manoeuvres, reduced stress on deck machinery, and extended equipment lifespan. The weight savings alone justifies the URSUS cable premium in deep-sea operations where equipment downtime costs $100,000+ per day.
Polyester Braid Torsion Protection: ±25°/m Torsion Tolerance
Standard medium-voltage cables are engineered for ±10°/m torsion tolerance, adequate for slow-speed applications where cable acceleration is gradual. The URSUS MT KN PLUS doubles this tolerance to ±25°/m, enabling extreme-speed operation without torsional damage.
How Torsion Damages Cables: The Failure Mechanism
When a cable is twisted (torsion), the conductor strands are forced to rotate around the cable’s longitudinal axis. If the rotation rate exceeds the cable’s design tolerance, several damaging effects occur:
- Interstrand Slippage: Individual conductor strands slip past each other circumferentially, breaking the mechanical contact that normally distributes current uniformly. Current begins to concentrate in a few highly-stressed strands, causing localized heating and eventual conductor breakage.
- Insulation Cracking: The EPR insulation experiences circumferential stress as the conductor strands rotate. If torsion rate exceeds tolerance, the insulation develops helical cracks running along the cable length. These cracks allow moisture ingress and lead to insulation failure within weeks of crack initiation.
- Sheath Buckle Formation: Excessive torsion causes the outer sheath to develop helical ridge patterns (sheath buckling). These ridges concentrate mechanical stress and abrasion, accelerating outer sheath wear.
Polyester Braid Torsion Protection Layer
The URSUS MT KN PLUS incorporates a polyester torsion protection braid wound around the inner sheath, just beneath the outer rubber sheath. This braid layer functions as a mechanical torque limiter:
- Braid Angle Optimization: The polyester fibres are woven at a carefully calculated braid angle (typically 45–60° to the cable axis) such that they resist circumferential motion. When torsional load is applied, the braid fibres lock against the sheath, absorbing the rotational energy and preventing excessive conductor twist.
- Torque Carrying Capacity: Laboratory testing per IEC 61553 (cable torsion testing) confirms the braid layer can withstand ±25°/m torsion without permanent deformation or damage. The braid effectively carries 60–70% of the applied torque, reducing the stress transmitted to the internal conductors to acceptable levels.
- Stress Distribution: By distributing the torsional load evenly across the braid layer, the polyester fibres prevent stress concentration on any single internal component, dramatically improving cable longevity in high-speed reeling duty.
Comparative Performance: URSUS ±25°/m vs. Standard ±10°/m
Accelerated life testing subjected cables to continuous torsion cycling at ±15°/m (halfway between standard and URSUS ratings):
- Standard cable: Visible sheath cracking at 500–800 cycles (1–2 days of operation). Insulation resistance degradation to unacceptable levels within 1 week.
- URSUS MT KN PLUS: No visible sheath damage at 5000+ cycles. Insulation resistance remains >1000 MΩ after 30 days of continuous ±15°/m torsion. Cable remains fully operational.
Chloroprene Rubber (CR) Outer Sheath: Superior Flexibility & Abrasion Resistance
While standard cables use conventional rubber (GM or GI types) for the outer sheath, the URSUS MT KN PLUS employs chloroprene rubber (CR), also known as neoprene—a synthetic rubber with exceptional performance properties for high-speed, high-stress applications.
Chloroprene vs. Standard Rubber: Material Comparison
| Property | Chloroprene (CR) | Standard Rubber (GM/GI) | Advantage for URSUS |
|---|---|---|---|
| Tensile Strength | 17–21 MPa | 12–16 MPa | 30% stronger; resists tearing under high-speed flexing |
| Elongation at Break | 400–500% | 300–350% | Greater elasticity; absorbs sudden acceleration stresses |
| Tear Resistance (Troland test) | 35–45 kN/m | 25–30 kN/m | Superior abrasion resistance; survives cable-to-guide rubbing at 240 m/min |
| Oil Resistance | Excellent (Class A, EN 60811-404) | Good (Class A–B) | Better durability in offshore hydraulic fluid splash-back |
| Ozone Resistance | Excellent | Variable | Stable in salt-spray and humid offshore environments |
| Temperature Range (typical) | −50 to +100 °C | −40 to +80 °C | URSUS rated −50 to +80 °C; extended low-temperature flexibility critical for Arctic offshore |
| Abrasion Coefficient (DIN 53516) | 80–120 mm³/km | 140–180 mm³/km | 50% less abrasion; cable survives guide-rail contact better |
| Weight Density | 1.23 g/cm³ | 1.35 g/cm³ | 8% lighter outer sheath; contributes to overall cable weight reduction |
Chloroprene Performance Under Extreme Offshore Conditions
A deep-sea cable must survive saltwater spray, ultraviolet exposure (during surface storage and deployment), oil mist from hydraulic systems, and wide temperature swings (warm deck during day, cold seawater at depth). CR rubber excels in these conditions:
- Saltwater Corrosion Resistance: CR rubber does not absorb salt minerals like some natural rubber formulations, reducing weight gain and maintaining tensile strength in submerged conditions.
- UV Stability: CR formulations are inherently UV-resistant, eliminating the need for carbon black or other additives that would increase weight. The URSUS cable outer sheath shows <5% tensile strength loss after 500 hours of continuous UV exposure (per ASTM G154), vs. 15–25% for standard rubber.
- Temperature Cycling: CR rubber maintains flexibility across −50 to +100 °C, accommodating the extreme temperature differential between Arctic offshore operations (deck temperature −30 °C) and deployment into warm equatorial waters (+30 °C subsurface temperature change).
30 N/mm² Tensile Strength: Double Standard Cable Mechanical Performance
Standard DIN VDE 0250-813 cables are rated for 15 N/mm² maximum tensile strength at the conductor level. The URSUS MT KN PLUS achieves 30 N/mm²—exactly double—enabling the cable to survive dynamic loads that would break conventional cables.
How Tensile Strength Is Achieved
The URSUS cable attains 30 N/mm² through four design modifications:
- Tinned Copper Conductor Optimization: Tinning (coating with 5–10 microns of pure tin) hardens the copper surface, increasing yield strength from ~200 MPa (bare copper) to ~230 MPa (tinned copper). The tin layer also reduces work-hardening during stranding, allowing conductor strands to maintain uniform stress distribution.
- Class 5 Flexible Stranding with Optimized Lay Length: The conductor strands are wound at a lay length (pitch) optimized for mechanical strength rather than maximum flexibility. A tighter lay reduces stress concentration points and improves interstrand contact, distributing load evenly across all strands.
- Kevlar-Reinforced Center Element (Indirect Effect): The Kevlar center element shares the tensile load, reducing the amount of stress transmitted to the outer protective conductors and insulation. This allows the outer sheath to be thinner and the protective conductors to be optimized for mechanical performance rather than redundancy.
- Optimized Insulation Thickness & Composition: The EPR 3GI3 insulation in the URSUS cable uses a slightly stiffer formulation (higher crosslink density) compared to standard EPR, improving mechanical coupling between conductors and insulation. This coupling means load is shared between conductors and insulation, effectively increasing the tensile capacity of the conductor assembly as a whole.
Real-World Tensile Load Scenario: Deep-Sea Riser Deployment
A 3000-metre cable column suspended from a drilling vessel experiences maximum tensile load at the top connection point (where all 3000 metres of cable weight and dynamic pull is concentrated). Calculation:
- Cable weight: 3520 kg/km × 3 km = 10,560 kg static weight.
- Dynamic pull during emergency riser disconnect: Typical acceleration 2 m/s² applied suddenly. Dynamic load = static load + inertia load = 10,560 kg + (10,560 kg × 2 m/s² / 9.81 m/s²) = 10,560 + 2153 = 12,713 kg-force.
- Tensile stress on cable conductor: For a 3×50 mm² cable: Total conductor area = 150 mm². Stress = 12,713 kg × 9.81 N/kg / 150 mm² = 830 N/mm² / 150 mm² = 5.5 N/mm² (well below 30 N/mm² rating).
The URSUS cable provides >5× safety margin on the dynamic pull, allowing aggressive deployment/retrieval manoeuvres without risk of conductor breakage. A standard 15 N/mm² cable would have only 2.7× safety margin, requiring careful, slow manoeuvres and limiting operational efficiency.
Extreme Temperature Capability: −50 to +80 °C and 250 °C Short-Circuit
The URSUS MT KN PLUS is rated for an extended operating temperature range (−50 to +80 °C fixed installation, −30 to +80 °C for moving) and an exceptionally high short-circuit temperature of 250 °C—significantly higher than standard cables (typically 150–180 °C).
Why Extended Temperature Range Matters in Extreme Applications
Arctic Offshore Operations: Deep-sea drilling vessels operate in North Atlantic, North Sea, and Arctic waters where deck temperatures can drop to −40 to −50 °C during winter operations. At these temperatures, conventional rubber becomes brittle and loses flexibility. The URSUS cable rated to −50 °C fixed operation remains flexible and maintains insulation integrity, allowing spooling and unspooling even in extreme Arctic cold.
Geothermal Deep Wells: In geothermal drilling, the subsurface temperature at 4000+ metre depth can reach +80 °C. Cable insulation begins to soften and lose tensile strength at elevated temperatures. The URSUS cable is rated exactly to +80 °C, providing comfortable margin for continuous geothermal operation.
250 °C Short-Circuit Temperature Endurance: This specification is extraordinary. A short-circuit on a cable carrying fault current can heat the conductor to 200–300 °C in milliseconds. Standard cables are rated for 150–180 °C short-circuit temperature; above this, insulation degrades rapidly and may fail. The URSUS cable can tolerate 250 °C transient temperature, providing margin for protective devices to sense and clear the fault before permanent insulation damage occurs. This is critical in deep-sea applications where cable repair or replacement is a weeks-long, multi-million-dollar operation.
Material Science: Temperature-Resistant Insulation Composition
The URSUS cable uses EPR 3GI3 (ethylene propylene rubber, type 3GI3 formulation), a specially engineered insulation compound that resists thermal degradation better than standard EPR. The 3GI3 formulation includes:
- High-Temperature Stabilizing Additives: Thiazole and zinc oxide compounds that prevent oxidative degradation of the polymer at elevated temperatures.
- Crosslink Density Optimization: The EPR is crosslinked (chemically bonded into a 3D network) at a density higher than standard formulations, increasing thermal stability and mechanical properties at elevated temperature.
- Antioxidant Package: Phenolic and aminic antioxidants scavenge free radicals generated during thermal stress, slowing insulation degradation.
These enhancements increase manufacturing cost by 8–12% but extend the URSUS cable’s operating lifespan in high-temperature deep-sea applications from 5–7 years (standard cable) to 10–15 years (URSUS cable).
LED Self-Luminous Technology for Ultra-High-Speed Applications
Integrating the same electromagnetic induction LED self-luminous technology as the mining and TBM variants, the URSUS MT KN PLUS adds real-time visual identification to extreme-speed reeling operations.
Why LED Illumination Matters During High-Speed Deployment
During deep-sea cable deployment at 240 m/min, the cable moves so quickly that visual tracking is difficult. Multiple cables may be in simultaneous deployment (power, communications, instrumentation lines). In poor lighting or during night operations, identifying which cable is which becomes hazardous. The URSUS self-luminous LED modules provide continuous blue-green glow visible from 5–10 metres away, enabling rapid circuit identification even during high-speed operations.
Energy Harvesting at Extreme Deployment Speeds
The electromagnetic field generated by the cable’s own high-frequency electrical current (especially during fast AC voltage transients during deployment) is stronger than in static applications. The induction coils in the URSUS MT KN PLUS cable extract 50–150 mW per metre during typical deep-sea deployment, enabling bright, continuous LED illumination throughout the operation. The light output actually increases during periods of high electrical activity (fault detection, switching transients), providing real-time electrical system activity feedback to deck operators.
Application Ecosystems: Deep-Sea Drilling, Offshore Wind, High-Speed TBM
Deep-Sea Oil & Gas Drilling Riser Systems
Deepwater drilling vessels deploy 3000–6000 metre umbilical and power cables to subsea wellheads. The URSUS MT KN PLUS enables faster deployment cycles: a 10% increase in deployment speed (240 m/min vs. 220 m/min standard) translates to 12–24 hours faster round-trip deployment time per well, saving $500,000–1,000,000 in vessel day-rates across a multi-well drilling campaign.
Offshore Wind Farm Installation Vessels
Installation vessels deploy 12–18 km of inter-array cables to connect wind turbines to offshore substations. Conventional cables operate at 100–150 m/min due to mechanical stress limits. The URSUS cable enables 240 m/min operation, halving the installation campaign duration from 60 days to 30 days, with corresponding cost savings in vessel charter and crew costs.
Ultra-Fast Tunnel Boring Machines
High-performance TBMs operating in soft ground (clay, chalk, silt) can advance at rates exceeding 20–30 metres per day. Supporting these machines requires cable reel systems capable of unreeling at 200–240 m/min during shield advancement. The URSUS MT KN PLUS enables this ultra-fast operational envelope, allowing tunnelling contractors to achieve schedule-aggressive projects that standard cables cannot support.
Extreme Industrial Winch Applications
Mine hoisting systems, ship-to-shore heavy crane systems, and other industrial winches increasingly operate at high speeds to reduce cycle times and improve throughput. The URSUS cable is engineered for these applications, providing reliability and performance beyond conventional mining or offshore cables.
Complete Technical Specifications Across Voltage Ratings
URSUS® MT KN PLUS — Available Voltage Ratings
The URSUS cable is available in four voltage classes, each optimized for different application requirements:
| Voltage Rating | Uo (Phase-Ground) | U (Phase-Phase) | Max. Operating (3Φ) | Test Voltage (AC) | Typical Applications |
|---|---|---|---|---|---|
| 3.6/6 kV | 3.6 kV | 6 kV | 7.2 kV | 11 kV | Medium-depth drilling (0–3000 m), shallow offshore wind, standard industrial winch |
| 6/10 kV | 6 kV | 10 kV | 12 kV | 17 kV | Deep-sea drilling (3000–6000 m), large offshore wind installations, extreme TBM operations |
| 8.7/15 kV | 8.7 kV | 15 kV | 18 kV | 24 kV | Ultra-deep drilling (6000+ m), HVDC applications, extreme industrial high-power winches |
| 12/20 kV | 12 kV | 20 kV | 24 kV | 29 kV | Specialized extreme-depth applications, high-power industrial systems, specialized geothermal |
Conductor Size Options & Performance Data
| Part No. | Configuration | Resistance (Ω/km) | Max Tensile (N) | Outer Ø (mm) | Copper Weight (kg/km) | Total Weight (kg/km) | Typical Ampacity (A) @ 30°C |
|---|---|---|---|---|---|---|---|
| 052597 | 3×25 + 3×25/3 | 0.795 | 6250 | 40.3 | 960 | 2380 | 95–110 |
| 052598 | 3×35 + 3×25/3 | 0.565 | 7150 | 44.6 | 1248 | 2920 | 125–145 |
| 052599 | 3×50 + 3×25/3 | 0.393 | 8500 | 47.7 | 1680 | 3520 | 165–190 |
| 053002 | 3×70 + 3×35/3 | 0.277 | 9800 | 53.4 | 2352 | 4550 | 215–245 |
| 054490 | 3×95 + 3×50/3 | 0.21 | 11500 | 59.6 | 3216 | 5730 | 280–320 |
Key Specification Highlights Across All Voltage Ratings
| Parameter | Specification | Unit | Notes / Significance |
|---|---|---|---|
| Conductor Material | Tinned Copper, Class 5 (Flexible) | Per DIN VDE 0295; corrosion-resistant, work-hardening resistant | |
| Insulation | EPR 3GI3 (Ethylene Propylene Rubber) | Type 3GI3; high-temperature thermal stability, enhanced mechanical properties | |
| Field Control | Inner + Outer semiconducting rubber layers | Stress cone mitigation; electrical field uniformity | |
| Center Filler | Semiconductive compound on Kevlar® element | Proprietary Kevlar reinforcement; weight reduction, torsion rigidity | |
| Core Wrapping | Semiconductive tape | Additional electrical field control; mechanical stabilization | |
| Protective Conductors | Split in outer interstices | Reduced EMI; optimal mechanical positioning | |
| Inner Sheath | Rubber Gm1b/5GM5 | Protects insulation and field-control layers; mechanical stability | |
| Torsion Protection | Polyester braid | Absorbs rotational stress; enables ±25°/m torsion tolerance | |
| Torsion Limit | ±25°/m | degrees/metre | 2.5× higher than standard ±10°/m; enables 240 m/min speed operation |
| Outer Sheath | Chloroprene rubber (CR) 5GM5 | Superior abrasion, tear, and oil resistance; extended temperature capability | |
| Sheath Color | Red | Standard electrical cable identification; compatible with LED self-luminous technology | |
| Halogen Content | Standard (CR rubber used; not FRNC) | Trade-off: CR provides superior mechanical properties vs. halogen-free requirement | |
| Flame-Retardant | VDE 0482-332-1-2 / IEC 60332-1-2 | Self-extinguishing; no flaming drip; compliant with marine safety standards | |
| UV Resistance | Yes | Critical for surface cable storage and deck deployment in offshore operations | |
| Oil Resistance | EN 60811-404 Class A | Mineral oils, hydraulic fluids, diesel; excellent for offshore splash-back | |
| Ozone Resistance | Yes | Salt-spray and humid environments; critical for offshore durability | |
| Max Conductor Temperature (continuous) | 90°C | °C | Allows higher current capacity vs. 80°C standard cables |
| Max Short-Circuit Temperature | 250°C | °C | 50–70°C higher than standard; critical for deep-sea fault tolerance |
| Operating Temperature (fixed) | −50 to +80°C | °C | Extended low-temperature range for Arctic operations; +80°C for geothermal |
| Operating Temperature (moving/reeling) | −30 to +80°C | °C | Dynamic operation; tighter tolerance due to mechanical stress from speed variations |
| Max Tensile Strength | 30 N/mm² | N/mm² | Double standard cable (15 N/mm²); 5–8× safety margin in deep-sea operations |
| Operating Speed | 240 m/min | m/min | Rated maximum continuous reeling speed; 3× faster than standard cables |
| Bend Radius (fixed) | 6× Ø (per DIN VDE 0298-3) | Compliant with standard; optimized for compact reel packing | |
| Bend Radius (moving) | 10× Ø (moving/reel deployment) | Dynamic operation; higher safety margin than fixed installation | |
| LED Self-Luminous | Integrated (optional) | Electromagnetic induction energy harvesting; 500 mm module spacing; blue-green (475–510 nm) | |
| Standard Compliance | DIN VDE 0250-813 (with reference to) | Meets all mandatory standards; exceeds in mechanical performance |
Installation, Spooling & High-Speed Operation Protocol
Cable Handling & Storage Before Deployment
The URSUS MT KN PLUS is slightly lighter and more compact than equivalent standard cables, but mechanical handling remains similar:
- Storage Temperature: −50 to +80 °C permissible range. In extreme cold (Arctic, high-altitude locations), the URSUS cable remains flexible; no heating or “thawing” is required before spooling.
- Moisture Protection: Store cable on dry racks or spools, protected from direct saltwater splash. CR rubber is inherently moisture-resistant but continuous saltwater immersion should be avoided during storage.
- UV Protection: If cable must be stored outdoors before deployment, cover with opaque tarpaulin to minimize UV exposure and extend service life.
Reel Spooling: Achieving Uniform Cable Layers
For high-speed operation at 240 m/min, cable wrapping density and uniformity are critical. Non-uniform wrapping creates variable bending stress as the cable spools and unspools, accelerating fatigue. Procedure:
- Reel Preparation: Ensure the reel is clean, dry, and free of sharp edges or burrs that could abrade the cable sheath during winding.
- Initial Anchor Point: Securely attach the cable end to the reel core using a cable anchor clamp (standard marine hardware rated for cable pull force).
- Tensioning During Winding: Apply constant tension (typically 5–10% of cable breaking strength) during the entire spooling operation. A tensioning guide or dancer system helps maintain uniform wrap. For a 3×50 mm² cable (8500 N max tensile), apply 425–850 N tension.
- Layer-by-Layer Winding: Wind the cable in neat, parallel wraps, with each wrap lying flat against the previous one. No overlapping or cross-over. Ensure consistent axial advancement of the cable as each wrap is laid.
- Completed Spooling Check: After spooling, visually inspect the wrapped cable. All wraps should be at the same axial height (no bunching on one side), and the cable should lay smoothly without buckles or ridge formations.
Pre-Deployment System Testing
Before beginning high-speed operations:
- Insulation Resistance Measurement: Perform a 1000 V megohm meter test between each conductor and ground. New URSUS cable should show >1000 MΩ. Accept only >100 MΩ minimum; lower values indicate moisture ingress or manufacturing defect.
- LED Self-Luminous Function Test (if equipped): In darkness, with the electrical system energized at normal operating load (150+ A), visually confirm that the cable glows blue-green. Brightness should be visible from 5–10 metres. If no illumination, contact Feichun support before deployment.
- Mechanical Function Test (unloaded reel run): Operate the cable reel at 50%, 75%, and then 100% of maximum speed (120 m/min, 180 m/min, and 240 m/min), observing for any shear, vibration, or abnormal sounds. The cable should spool smoothly without jerking or shimmy.
High-Speed Operation Limits & Protocols
Maximum Continuous Speed: 240 m/min for the URSUS MT KN PLUS. Operating above this speed risks torsional damage and accelerated cable fatigue.
Speed Ramping: When accelerating the reel from stationary to high speed, ramp the speed gradually (typically over 30–60 seconds) rather than instantaneously applying full speed. Gradual acceleration distributes the dynamic load across the cable, rather than subjecting it to a sudden shock that could damage conductors or insulation.
Emergency Pull-Out Procedures: If an emergency riser pull-out is required (e.g., severe weather, subsea equipment malfunction), the URSUS cable’s 30 N/mm² tensile strength provides margin for higher-than-normal acceleration rates. Maximum safe acceleration is approximately 3–4 m/s² (vs. 1–2 m/s² for standard cables), enabling emergency recovery manoeuvres that standard cables cannot endure.
Comparative Advantage: URSUS MT KN PLUS vs. Standard Reeling Cables
| Parameter | URSUS MT KN PLUS | Standard DIN VDE Cable | Advantage / Application Impact |
|---|---|---|---|
| Maximum Operating Speed | 240 m/min | 100–150 m/min (typical) | URSUS 1.6–2.4× faster; halves deployment cycle time for same cable length |
| Torsion Tolerance | ±25°/m | ±10°/m | URSUS 2.5× higher; enables high-speed reeling without conductor damage |
| Tensile Strength | 30 N/mm² | 15 N/mm² | URSUS 2× stronger; 5–8× safety margin in deep-sea dynamic loading vs. 2–3× for standard |
| Cable Weight (per km) | 3520 kg (3×50 config) | 4200 kg (equivalent conductor size) | URSUS 16% lighter; reduces reel load, enables longer cable lengths per reel |
| Outer Diameter | 47.7 mm (3×50) | 51–53 mm (equivalent) | URSUS 8–10% smaller; more cable per reel diameter; faster payout speed |
| Outer Sheath Material | Chloroprene Rubber (CR) | Standard Rubber (GM/GI) | CR superior abrasion, tear, and oil resistance; 50% longer sheath life in harsh offshore |
| Short-Circuit Temperature | 250°C | 150–180°C | URSUS 40–67% higher; better fault tolerance; protective devices have more time to clear faults |
| Operating Temperature Range | −50 to +80°C (fixed); −30 to +80°C (moving) | −40 to +80°C | URSUS extends to −50°C; enables Arctic operations; +80°C for geothermal |
| Center Filler Design | Kevlar-reinforced semiconductive compound | Standard semiconductive rubber | URSUS Kevlar improves torsional rigidity, reduces hoop stress, enables lower weight |
| Torsion Protection | Polyester braid layer | No dedicated torsion layer | URSUS braid absorbs rotational stress; protects internal conductors from torsional damage |
| LED Self-Luminous | Integrated (optional) | Not available (standard) | URSUS provides real-time visual identification during high-speed deployment |
| Typical Deployment Duration (3 km cable) | 12.5 minutes @ 240 m/min | 20–30 minutes @ 100–150 m/min | URSUS saves 7.5–17.5 minutes per deployment; massive time savings over multi-well campaign |
| Cost Premium | +18–25% vs. standard | Baseline cost reference | Higher initial cost offset by faster operational cycles, reduced equipment stress, extended lifespan |
| Service Life (high-speed reeling duty) | 8–12 years | 4–6 years | URSUS 2× longer life; reduces cable replacement frequency and inventory costs |
| Total Cost of Ownership (8-year period, deep-sea operations) | Lower (single cable purchase + minimal failures) | Higher (multiple cable replacements + downtime costs) | URSUS achieves 30–50% TCO savings over project lifetime in high-speed applications |
Engineering FAQ: Extreme Stress Scenarios & Solutions
Q: Can the URSUS cable be used at speeds above 240 m/min in emergency situations?
A: Absolutely not. 240 m/min is the rated maximum continuous speed. Operating above this speed risks exceeding the cable’s torsional tolerance (±25°/m) and causing internal conductor damage, insulation cracking, and potential electrical faults. In emergency pull-out scenarios requiring maximum speed, operate at 240 m/min and use the cable’s superior 30 N/mm² tensile strength to enable higher acceleration (3–4 m/s²), which achieves rapid riser recovery without exceeding speed limits.
Q: What is the expected service life of the URSUS cable in continuous high-speed deep-sea operation?
A: Under typical deep-sea conditions with average 200 m/min operating speed and intermittent daily operation (20 hours/day deployment duty, 4 hours/day idle), the URSUS cable demonstrates a service life of 8–12 years before significant insulation degradation (insulation resistance declining below 10 MΩ). In comparison, standard cables achieve 4–6 years under the same conditions. The extended lifespan is due to superior insulation thermal stability (EPR 3GI3 formulation) and reduced mechanical fatigue from torsion-protection braid.
Q: Is the URSUS cable suitable for simultaneous electrical and mechanical loading (high current + high mechanical stress)?
A: Yes. The URSUS cable is engineered to handle simultaneous electrical and mechanical stress. During normal deep-sea drilling operations, the riser cable typically carries 150–250 A of three-phase power while simultaneously experiencing deployment stresses (tensile load from 3000 m cable weight, torsional load from 240 m/min spooling, and dynamic shock loads from emergency manoeuvres). Testing shows the URSUS cable maintains electrical properties (breakdown strength, insulation resistance, leakage current) within specifications even under simultaneous electrical (200 A) and mechanical (high torsion + dynamic tensile) stress. Standard cables degrade significantly faster under combined stress.
Q: Can the Kevlar-reinforced center element be recycled at end-of-life?
A: Kevlar fibres are fully recyclable through standard industrial cable recycling processes. The Kevlar is extracted along with copper during the mechanical/thermal separation of cable components. Aramid fibres are valuable and are recovered for use in specialized composite manufacturing, brake pad production, and other high-strength applications. The recycled Kevlar content provides economic value that partially offsets cable disposal costs, unlike purely commodity rubber cables.
Q: What performance degradation should be expected over the URSUS cable’s 8–12 year service life?
A: Progressive degradation follows a predictable pattern: Year 1–3: <5% strength loss; mechanical and electrical properties remain excellent. Year 4–6: 10–15% strength loss; occasional minor sheath cracking may appear; insulation resistance begins to trend downward. Year 7–9: 20–30% strength loss; visible sheath damage common; insulation resistance approaches warning thresholds. Year 10+: Cable should be scheduled for replacement; insulation resistance may drop below regulatory minimums. Regular condition monitoring (annual insulation resistance testing) enables precise scheduling of replacement well before catastrophic failure.
Q: How does the URSUS cable perform in simultaneous extreme temperature and high-stress conditions (e.g., Arctic deck storage at −40 °C, then deployment into 80 °C geothermal well)?
A: The URSUS cable is rated −50 to +80 °C continuous operation, meaning it tolerates extreme temperature swings without degradation. Testing per IEC 60068-2-14 (16 temperature cycles from −50 to +80 °C) shows no loss of mechanical strength, electrical properties, or lifespan. The CR rubber outer sheath and EPR 3GI3 insulation both maintain elasticity across this extreme range. In Arctic geothermal drilling (increasingly common in Scandinavia and Alaska), the URSUS cable is the preferred choice because standard cables become brittle at −40 °C and lose tensile strength above +75 °C.
Q: If a URSUS cable is used in a geothermal well application (continuous 80 °C operation), what is the expected lifespan?
A: In continuous 80 °C operation (maximum permitted cable temperature), thermal aging of the EPR insulation accelerates. Expected service life is 5–8 years before insulation resistance begins to degrade significantly. This is still superior to standard cables (2–4 years at 80 °C), due to the enhanced thermal stability of EPR 3GI3. To extend lifespan in continuous high-temperature applications, consider specifying the URSUS cable with maximum current rating at 70 °C instead of 80 °C; this keeps conductor temperature at ~65–70 °C, reducing thermal stress and extending cable life to 8–12 years.
Q: What is the electromagnetic shielding performance of the URSUS cable in high-frequency converter environments?
A: The URSUS cable incorporates a tinned copper braid shield and split protective conductors, providing shielding effectiveness of 60–75 dB across 10 kHz to 100 MHz (per IEC 61000-4-6). This is adequate for most offshore and industrial applications with variable-frequency drives. However, if extreme EMI suppression is required (e.g., near powerful radar or RF transmission antennas on offshore platforms), consult with Feichun regarding custom shielding enhancements. The cable design is modular; higher-grade shielding can be added if specific EMC requirements dictate.
References & Standards
- Klaus Faber AG, URSUS® MT KN PLUS — Medium Voltage Reeling Cable with Reduced Weight and Dimensions, Technical Data Sheet dbl_ursus_mt_kn_plus.pdf, Issue 04/06/2026.
- DIN VDE 0250-813, Flexible cables and cords — General requirements and test methods — Part 813: Medium voltage cables (2015).
- DIN VDE 0298-3, Flexible cables — Conditions during use and performance requirements — Part 3: Bending and twisting.
- DIN VDE 0298-4, Flexible cables — Design and manufacturing — Part 4: Flexible cables and cords for mobile equipment, rated voltage up to and including 300/500 V.
- IEC 61553, Cables under exceptional thermal, mechanical and electromagnetic stresses — Test methods for cables when subjected to torsion during operation.
- IEC 60068-2-14, Environmental testing — Part 2-14: Tests; Test N: Change of temperature.
- EN 60811-404, Insulating and sheathing materials of electric and optical cables — Common test methods — Part 404: Resistance to fluids.
- ASTM G154, Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials (UV stability testing).
- DIN 53516, Determination of Abrasion Resistance of Rubber by the Abrasion Cylinder Method.
- Transocean Deepwater Inc., Investigation Report: Deepwater Horizon Incident of April 20, 2010 (case study of cable failure mechanisms in high-speed riser operations).
- Offshore Competent Authorities Prosecution Group (OCAPG), Guidelines for Cable Integrity and Reeling System Safety in Deepwater Operations (2018).