Type FE4OHH2R GAALFLEX® VFD

Inverter, connection to frequency converters, 0,6/1 kVV

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
GAALFLEX® VFD FE4OHH2R: 600V/1000V European Standard Cost-Effective Variable Frequency Drive Cable with XLPE Insulation, Special PVC RZ Black Jacket, Standard Industrial Performance, +250°C Short-Circuit Tolerance, Aluminum Tape + Red Copper Braid Shielding, 2/3/4-Phase Industrial Motor, 10–240 mm² Flexible Class 5, 8×D Bending Radius, EN 50265/IEC 60332 Compliance | European Standard Industrial VFD Cable
Standard Industrial · 600V/1000V · XLPE Cost-Effective GAALFLEX® VFD FE4OHH2R · Black PVC RZ · 2/3/4-Core Flexible 10–240 mm² · 8×D Bend · EN 50265/IEC 60332 · +250°C Short-Circuit

GAALFLEX® VFD FE4OHH2R: 600V/1000V European Standard Cost-Effective Variable Frequency Drive Cable with XLPE Insulation, Special PVC RZ Black Jacket, Standard Industrial Performance, Exceptional +250°C Short-Circuit Tolerance, Aluminum Tape + Red Copper Braid Shielding, 2/3/4-Phase Industrial Motor, 10–240 mm² Flexible Class 5, 8×D Minimum Bending Radius, Enhanced EN 50266-2-4/IEC 60332-3-24 Flame Testing | European Standard Industrial VFD Cable

European standard 600V/1000V cost-effective VFD cable combining XLPE (cross-linked polyethylene) insulation with standard industrial performance, black special PVC RZ outer jacket, flexible Class 5 red copper, aluminum tape + red copper braid shielding, and professional standard industrial motor integration—addressing standard industrial frequency converter specification (600V/1000V), cost-sensitive applications, flexible 2/3/4-core topologies, exceptional short-circuit fault tolerance (+250°C), flexible motor routing (8×D bend radius), enhanced flame testing capability, and comprehensive European standard industrial automation infrastructure simultaneously.

Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division Published May 9, 2026 Advanced technical analysis ~145 minutes with 70+ specification tables European Standard Industrial VFD Cable · XLPE · Cost-Effective · 2/3/4-Core Flexibility
Voltage Rating
600V/1000V
Standard industrial
Insulation
XLPE
Standard industrial
Outer Jacket
PVC RZ Black
Special industrial
Conductor Range
10–240 mm²
Industrial spectrum
Configuration
2/3/4-Core
Maximum flexibility
Temperature
−20/0 to +90°C
Standard industrial
Cost Profile
Cost-Effective
XLPE standard
Fire Rating
EN 50265/50266/IEC 60332
Enhanced testing
Bending Radius
8×D Minimum
Standard flexible
Short-Circuit
+250°C Max
Fault tolerance

1. XLPE Insulation: Standard Industrial Electrical Performance

GAALFLEX® VFD FE4OHH2R utilizes standard XLPE (cross-linked polyethylene) insulation providing cost-effective electrical stability and flame-retardant characteristics optimized for standard industrial frequency converter applications.

XLPE vs. Proprietary Insulation: Cost-Performance Strategy

Cost optimization approach: GAALFLEX VFD FE4OHH2R uses standard XLPE (industry-standard, widely available) vs. proprietary GAALTHERM® (VFD 1100/1200) or HEPR (FG16OHH2R building). XLPE provides solid industrial performance with maximum cost efficiency. Result: lowest cost-per-meter, standard supply chain, full electrical compliance without premium material cost.

2. Special PVC RZ Black Jacket: Industrial Durability & Protection

GAALFLEX® VFD FE4OHH2R features black RAL 7035 special PVC type RZ outer sheath providing industrial standard protection and mechanical durability at cost-effective specification.

3. Flexible 2/3/4-Core Configuration: Maximum Application Topology

GAALFLEX® VFD FE4OHH2R offers unprecedented flexibility with 2-core power, 3-core standard, and 4-core configurations enabling standardized specification across diverse industrial VFD system topologies within single product family.

4. Standard Temperature Range: −20/0 to +90°C Industrial Operation

GAALFLEX® VFD FE4OHH2R provides −20°C fixed/0°C flexible minimum through +90°C maximum enabling standard industrial facilities without extreme cold or tropical heat requirements.

5. Enhanced Flame Testing: EN 50265/50266 & IEC 60332-3-24 Compliance

GAALFLEX® VFD FE4OHH2R meets enhanced flame testing per DIN VDE 0482-265-2-1, EN 50265-2-1, IEC 60332-1-2 (vertical), plus additional EN 50266-2-4 / IEC 60332-3-24 (tray) testing ensuring comprehensive fire safety.

6. 8×D Bending Radius: Standard Industrial Installation Flexibility

GAALFLEX® VFD FE4OHH2R provides 8×D minimum bending radius enabling standard industrial installation through motor junction boxes and equipment systems without kinking.

7. Comparative Analysis: FE4OHH2R (XLPE Standard) vs. FG16OHH2R (Building) & VFD 1100 (Premium Gray)

Table 7.1-A — Performance comparison: GAALFLEX FE4OHH2R (XLPE standard), FG16OHH2R (building), and VFD 1100 (premium gray)
MetricFE4OHH2R XLPE StandardFG16OHH2R Building CodeVFD 1100 Premium GrayWinner
INSULATION & COST PROFILE
Insulation typeXLPE (standard)HEPR (halogen-free)GAALTHERM® 530FE4OHH2R
Cost tierLowest (XLPE)Premium (halogen-free)ModerateFE4OHH2R
Regulatory complianceIndustrial onlyBuilding (CPR Cca)Industrial onlyFG16OHH2R
CONFIGURATION & FLEXIBILITY
2-core optionYes (power)No (3/4-core only)No (3-core only)FE4OHH2R
3-core optionYesYesYesAll equal
4-core optionYesNo (limited)NoFE4OHH2R
TEMPERATURE & FAULT PERFORMANCE
Min. temperature−20/0°C−15°C−15°CFG16OHH2R/1100
Short-circuit tolerance+250°C+250°C+250°CAll equal
FE4OHH2R Positioning: Cost-Effective Standard Industrial

Choice strategy: FE4OHH2R (XLPE, 2/3/4-core) = lowest-cost standard industrial VFD cable with maximum configuration flexibility. FG16OHH2R (HEPR, building) = mandatory for building code compliance. VFD 1100 (gray GAALTHERM® 530) = premium industrial gray jacket. Choose FE4OHH2R for cost-sensitive standard industrial; choose others for premium or regulatory-driven applications.

8. Complete GAALFLEX® VFD FE4OHH2R SKU Catalog (20+ Standard Industrial Configurations)

GAALFLEX® VFD FE4OHH2R standard industrial VFD cables span comprehensive 10–240 mm² conductor range with 2-core, 3-core, and 4-core configurations optimized for diverse standard industrial frequency converter systems.

Table 8.1-B — GAALFLEX® VFD FE4OHH2R 600V/1000V (XLPE, PVC RZ black jacket): Selected SKU portfolio (20+ total configurations) — 2/3/4-Core Standard Industrial Version
ConfigurationSize (mm²)O.Ø (mm)Cable Weight (kg/km)Standard Application
2-CORE POWER (10–25 mm²) — Power Supply Small Load
2 x 10 / 1010 + 10 mm²19650Small circuit power
2 x 25 / 2525 + 25 mm²241210Medium power supply
3-CORE STANDARD (10–240 mm²) — Industrial Motor Distribution
3 x 10 / 1010 × 3 + 10 mm²19.573025 kW motor
3 x 25 / 1625 × 3 + 16 mm²26155060 kW standard
3 x 50 / 2550 × 3 + 25 mm²292250100 kW system
3 x 95 / 5095 × 3 + 50 mm²384100150 kW industrial
3 x 240 / 120240 × 3 + 120 mm²579950400+ kW facility
3-CORE EQUAL SHIELDING (25–185 mm²) — Balanced Power Distribution
3 x 25 / 2525 × 3 + 25 mm²261600Balanced 60 kW
3 x 70 / 7070 × 3 + 70 mm²343350Balanced 150 kW
4-CORE INDUSTRIAL (10–240 mm²) — Power + Control + Signal
4 x 10 / 1010 × 4 + 10 mm²20.5890Small control + power
4 x 25 / 1625 × 4 + 16 mm²28180060 kW + control
4 x 95 / 5095 × 4 + 50 mm²43.55000150 kW + signal
4 x 240 / 120240 × 4 + 120 mm²62.511600Industrial maximum
All GAALFLEX® VFD FE4OHH2R SKUs (2/3/4-core standard): 600V/1000V (0.6/1 kV), XLPE insulation, flexible Class 5 red copper (IEC 60228, DIN VDE 0295), aluminum tape (100% covering) + red copper braid shielding, black RAL 7035 special PVC type RZ outer sheath, 2-core (power), 3-core (standard), 4-core (control+power) per DIN VDE 0293-308, 10–240 mm² comprehensive range, 8×D minimum bending radius, temperature −20/0 to +90°C standard industrial, +250°C maximum short-circuit, 4 kV test voltage per DIN VDE, DIN VDE 0482-265-2-1 / EN 50265-2-1 / IEC 60332-1-2 (vertical flame) + EN 50266-2-4 / IEC 60332-3-24 (tray flame) enhanced flame testing, suitable per EN 55011 / DIN VDE 0875 / EN 61800-3, RoHS & CE certified. Optimized for cost-effective standard industrial frequency converter systems (10–240 mm² full spectrum), exceptional short-circuit survivability (+250°C), flexible 2/3/4-core configuration enabling standardized specification across diverse VFD topologies, standard temperature range (−20 to +90°C), flexible 8×D installation, European standard specification, and comprehensive cost-effective standard industrial VFD automation infrastructure with XLPE standard insulation, flexible multi-core configuration, exceptional fault tolerance, and professional standard industrial frequency converter system integration.

Technical References

  1. IEC. (2023). IEC 60228: Conductors of Insulated Cables—Flexible Class 5 Copper.
  2. DIN VDE. (2023). DIN VDE 0482-265-2-1: Vertical Flame Propagation Test.
  3. European Committee. (2023). EN 50265-2-1: Fire Test for Non-Metallic Materials.
  4. DIN VDE. (2023). DIN VDE 0482-266-2-4: Horizontal Tray Flame Test for Power Cables.
  5. European Committee. (2023). EN 50266-2-4: Tray Flame Test—Power Cables.
  6. IEC. (2023). IEC 60332-3-24: Tray Flame Test Category C.
  7. Feichun Cable Engineering. (2023). VFD FE4OHH2R: XLPE Standard Industrial VFD Cable.
  8. Industrial Motor Standards. (2023). 2/3/4-Core Configuration Flexibility for VFD Systems.

European Standard Industrial VFD Cable Solutions

For 600V/1000V European standard industrial frequency converter cable solutions with XLPE insulation, cost-effective PVC RZ jacket, and flexible 2/3/4-core configuration: [email protected] | Industrial Drive Solutions Division | Anhui Feichun Special Cable Co., Ltd.

Cost-Effective XLPE Standard[email protected]
2/3/4-Core Flexible Configuration[email protected]
+250°C Short-Circuit Rated[email protected]
Industrial Drive Solutions DivisionAnhui Feichun Special Cable Co., Ltd.

GAALFLEX® VFD FE4OHH2R: 600V/1000V European Standard Cost-Effective Industrial VFD Cable with XLPE Insulation & PVC RZ Jacket — 600V/1000V cost-effective VFD cable, XLPE insulation, black RAL 7035 special PVC RZ jacket, exceptional +250°C maximum short-circuit, flexible Class 5 red copper per IEC 60228, aluminum tape (100% covering) + red copper braid shielding, 2-core power / 3-core standard / 4-core power+control per DIN VDE 0293-308, 10–240 mm² comprehensive range, 8×D minimum bending radius, temperature −20/0 to +90°C standard industrial, 4 kV test voltage, DIN VDE 0482-265-2-1 / EN 50265-2-1 / IEC 60332-1-2 (vertical) + EN 50266-2-4 / IEC 60332-3-24 (tray) enhanced flame testing, suitable per EN 55011/DIN VDE 0875/EN 61800-3, RoHS & CE certified. Comprehensive portfolio (20+ standard SKUs) for European cost-effective industrial motor VFD systems.

European standard industrial VFD cable for cost-sensitive frequency converter systems: 600V/1000V dual-voltage European standard specification, cost-effective XLPE insulation enabling lowest total-cost-of-ownership, exceptional +250°C short-circuit survivability enabling extreme fault tolerance, flexible 2/3/4-core configuration enabling standardized specification across diverse VFD power/control/signal topologies, standard temperature range (−20 to +90°C) for typical industrial facilities, flexible 8×D installation, complete 10–240 mm² industrial motor spectrum, enhanced flame testing (EN 50265/50266 + IEC 60332-3-24), and comprehensive cost-effective standard industrial VFD automation infrastructure with XLPE standard insulation, flexible multi-core configuration, exceptional fault tolerance, and professional standard industrial frequency converter system integration.

Previous Article

Type FG16OHH2R16 GAALFLEX® VFD

Next Article

Type FG7(O)CR GAALFLEX® VFD

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注