PRYSMIAN Cordaflex® (N)SHTOEU (SMK)-V-FO

0.6/1 kV Extra Heavy-Duty Vertical Reeling Cable with Integrated Fiber Optics — Class “FS” Exceptionally Fine Stranded Conductors, Polyolefin Thin-Wall Insulation, Aramide Self-Supporting Element, PCP Rubber Sheath, 4×OD Moving Bending Radius (Tightest of Any Vertical Cable), 240 m/min Spreader Speed, −50°C Fixed, 12 Configurations from 44×2.5 to 56×2.5 with E9/G50/G62.5 Fibers — The Ultimate Spreader Control + Data Cable for Automated STS Crane Vertical Reel Systems

This Cable Exists in a Category of One: No Other Cable Combines Class FS Ultra-Flexibility, Polyolefin Thin-Wall Compactness, Aramide Vertical Self-Supporting, Integrated Multi-Fiber Optics, and 4×OD Moving Bending — Fitting 56 Control Cores + 12 Optical Fibers Into Just 44.3 mm OD While Hanging Vertically at 240 m/min Under Extra Heavy Duty Simultaneous Tensile and Torsional Stress

Cordaflex SMK-V-FO replacement, Prysmian Cordaflex alternative, NSHTOU FO cable, NSHTOEU SMK V, vertical reeling composite cable, fiber optic spreader cable, STS crane spreader cable, Kevlar core reeling cable, 0.6/1kV composite cable, yellow rubber FO cable, 5GM5 rubber sheath, heavy duty vertical cable, dynamic load crane cable, Feichun reeling cable, Feichun crane cable, Chinese premium crane cable, import substitution cable, 160 m/min crane cable, continuous flexing FO cable, UV resistant vertical cable, ozone resistant crane cable, flame retardant rubber cable, harbour crane electrification, SCADA crane cable, HD camera spreader cable, anti torsion vertical cable, robust industrial composite cable, flexible power transmission, torsional stress cable, high tensile strength crane cable, port terminal electrification, mechanical stress reeling, offshore crane data cable, motorized drum cable, European standard equivalent, Lapp cable FO alternative, TF Kable reeling equivalent, Draka Cordaflex alternative, sanction free crane cable, direct factory reeling cable, custom crane cable, heavy duty hoist cable, VDE 0250-814 composite, zero elongation vertical cable, single mode fiber reeling, multi mode crane cable, smart port electrification, hybrid power and data spreader, diverter sheave cable, high speed vertical winding
Cordaflex SMK-V-FO replacement, Prysmian Cordaflex alternative, NSHTOU FO cable, NSHTOEU SMK V, vertical reeling composite cable, fiber optic spreader cable, STS crane spreader cable, Kevlar core reeling cable, 0.6/1kV composite cable, yellow rubber FO cable, 5GM5 rubber sheath, heavy duty vertical cable, dynamic load crane cable, Feichun reeling cable, Feichun crane cable, Chinese premium crane cable, import substitution cable, 160 m/min crane cable, continuous flexing FO cable, UV resistant vertical cable, ozone resistant crane cable, flame retardant rubber cable, harbour crane electrification, SCADA crane cable, HD camera spreader cable, anti torsion vertical cable, robust industrial composite cable, flexible power transmission, torsional stress cable, high tensile strength crane cable, port terminal electrification, mechanical stress reeling, offshore crane data cable, motorized drum cable, European standard equivalent, Lapp cable FO alternative, TF Kable reeling equivalent, Draka Cordaflex alternative, sanction free crane cable, direct factory reeling cable, custom crane cable, heavy duty hoist cable, VDE 0250-814 composite, zero elongation vertical cable, single mode fiber reeling, multi mode crane cable, smart port electrification, hybrid power and data spreader, diverter sheave cable, high speed vertical winding
PRYSMIAN Cordaflex® (N)SHTOEU (SMK)-V-FO 0.6/1 kV Extra Heavy-Duty Vertical Reeling Cable with Fiber Optics: Class FS Exceptionally Fine Stranded, Polyolefin Insulation, Aramide Self-Supporting, PCP Rubber, 4×OD Moving Bend, 240 m/min, −50°C Fixed, 12 Configurations 44–56×2.5+FO, for STS Crane Spreader Vertical Reels, Drumspreader & Hoisting Systems | FeiChun Cable
Class “FS” — Exceptionally Fine Stranded Polyolefin Thin-Wall Insulation Aramide Self-Supporting · Vertical 4×OD Moving · 240 m/min · Yellow PCP

PRYSMIAN Cordaflex® (N)SHTOEU (SMK)-V-FO

0.6/1 kV Extra Heavy-Duty Vertical Reeling Cable with Integrated Fiber Optics — Class “FS” Exceptionally Fine Stranded Conductors, Polyolefin Thin-Wall Insulation, Aramide Self-Supporting Element, PCP Rubber Sheath, 4×OD Moving Bending Radius (Tightest of Any Vertical Cable), 240 m/min Spreader Speed, −50°C Fixed, 12 Configurations from 44×2.5 to 56×2.5 with E9/G50/G62.5 Fibers — The Ultimate Spreader Control + Data Cable for Automated STS Crane Vertical Reel Systems

This Cable Exists in a Category of One: No Other Cable Combines Class FS Ultra-Flexibility, Polyolefin Thin-Wall Compactness, Aramide Vertical Self-Supporting, Integrated Multi-Fiber Optics, and 4×OD Moving Bending — Fitting 56 Control Cores + 12 Optical Fibers Into Just 44.3 mm OD While Hanging Vertically at 240 m/min Under Extra Heavy Duty Simultaneous Tensile and Torsional Stress

Anhui Feichun Special Cable Co., Ltd. Published April 2026 13 min technical read

Introduction: A Category of One

The PRYSMIAN Cordaflex® (N)SHTOEU (SMK)-V-FO exists in a product category that it alone occupies. Every other cable in this guide series makes engineering trade-offs: TRATOSLIGHT cables sacrifice sheath toughness for speed; URSUS cables sacrifice speed for mechanical strength; Trommelflex KSM-S FO cables sacrifice vertical self-supporting for horizontal drum optimisation. The (SMK)-V-FO makes no trade-offs. It simultaneously achieves:

Class “FS” exceptionally fine stranded conductors (the finest stranding available — finer than Class 6), polyolefin thin-wall insulation (the thinnest insulation in this guide — enabling 56 cores + fiber in 44.3 mm OD), aramide self-supporting element (for vertical suspension without conductor stress), 4×OD moving bending (the tightest dynamic bending of any vertical cable), 240 m/min spreader speed, integrated fiber optics (up to 12 fibers in multiple tube arrangements), and PCP rubber sheath for extra heavy-duty mechanical and environmental protection — all in a single cable designed for the most advanced automated STS crane spreader systems in the world.

This is a SPREADER CONTROL Cable — Not a Power Cable

Unlike the Trommelflex KSM-S FO and Cordaflex SMRT FO (which are three-phase power cables with fiber), the (SMK)-V-FO is a multi-core control cable — 44 to 56 cores at 2.5 mm² carrying spreader control signals, actuator power, sensor circuits, and safety interlocks alongside fiber optic data. This cable connects to the spreader, not to the main hoist motor. It rides on the vertical spreader reel (or drumspreader), hanging from the trolley to the spreader headblock — a completely different application from the horizontal power reeling cables discussed in the Trommelflex and Cordaflex SMRT articles.

Technical Anatomy: Full Specification

Cordaflex® (SMK)-V-FO Specifications (per Klaus Faber Datasheet dbl_nshtoeu_smk_v_fo.pdf, Issue 04/01/2026)
ParameterSpecificationUnique Distinction
StandardVDE 0250 p. 814—
VoltageUo/U: 0.6/1 kV. Test: 3.5 kV.—
ConductorBare copper. Class “FS” = exceptionally fine stranded.★ Finest stranding — finer than Class 6. Wire Ø ≤ 0.05 mm.
InsulationPolyolefin★ Only polyolefin-insulated cable in this guide. Thin-wall = compact OD.
Inner SheathRubber compound based on PCP (polychloroprene)PCP rubber — tougher than standard 5GM3.
Self-SupportingAramide★ Vertical self-supporting — “-V” designation.
TorsionSynthetic braid. ±50°/m.—
Outer SheathRubber compound based on PCP. Yellow.Yellow = vertical cable identifier.
UV / Oil ResistantYes / EN 60811-2-1—
Temperature (Fixed)−50°C to +80°C★ Coldest fixed rating of any cable in this guide.
Temperature (Moving)−35°C to +80°C—
Bending (Fixed)6×OD—
Bending (Moving)4×OD★ Tightest moving bend of any vertical cable.
Speed240 m/minHigh-speed vertical spreader operation.
Fiber OptionsE9/125, G50/125, G62.5/125Multiple tube arrangements (1×6, 1×8, 3×2, 3×3, 4×3).
Core IDGreen-yellow + numbers—

12 Configurations: Complete Matrix

Cordaflex® (SMK)-V-FO — All 12 Configurations
Part No.ConfigurationRl [Ω/km]Ibl [A]Ø [mm]Cu [kg/km]G [kg/km]
44-Core Series (38.5 mm OD)
05216444×2.5 + 3×(3G50 FO)7.983038.51,2322,380
05223044×2.5 + 1×(8G62.5 FO)7.983038.51,2322,380
05344544×2.5 + 4×(3G62.5 FO)7.983038.51,2322,447
50–52-Core Series (43.1 mm OD)
05239850×2.5 + 1×(6G50 FO)7.983043.11,3992,946
05491552×2.5 + 4×(3G62.5/125)7.983043.11,4553,039
56-Core Series (44.3 mm OD) — Maximum Core Count
05439956×2.5 + 3×(2E9/125)7.983044.31,5673,232
05440056×2.5 + 3×(2G50/125)7.983044.31,5673,232
05440156×2.5 + 3×(2G62.5/125)7.983044.31,5673,232
05455856×2.5 + 3×(3E9/125)7.983044.31,5673,225
05455956×2.5 + 3×(3G50/125)7.983044.31,5673,225
05456056×2.5 + 3×(3G62.5/125)7.983044.31,5673,225
05249756×2.5 + 4×(3G62.5 FO)7.983044.31,5673,243
No Fzp/Fzd Listed — Why?

Unlike the Cordaflex SMRT and Trommelflex KSM-S, the (SMK)-V-FO datasheet does not list Fzp or Fzd values. The application note states: “Where excessive stress, particularly high dynamic tensile force may be expected, e.g. as a result of high acceleration figures, the permissible stress limits have to be determined individually.” This means the tensile capacity depends on the specific cable length, vertical drop, reel configuration, and acceleration profile of each crane — Feichun’s engineering team calculates the aramide core’s tensile capacity for your specific installation on request.

Class “FS” — Beyond Class 6: The Finest Stranding in Crane Cabling

The (SMK)-V-FO specifies Class “FS” = exceptionally fine stranded conductors — a proprietary flexibility classification that exceeds IEC 60228 Class 6 (very flexible). While Class 6 specifies a maximum wire diameter of 0.16 mm for 2.5 mm², Class FS uses wires with diameters of approximately 0.05 mm or less — individual strands thinner than a human hair. This extreme fineness enables the cable to achieve the 4×OD moving bending radius — bending the 44.3 mm OD cable around a drum with just 177 mm radius during dynamic reeling at 240 m/min.

The Class FS designation is shared with only one other cable family in this guide series: the Spreaderflex basket cable range. Both applications demand extreme flexibility in compact diameters — the (SMK)-V-FO because it must bend tightly around vertical reel drums while carrying 56 cores + fiber, and the Spreaderflex because it must fold and unfold in gravity-fed baskets. The FS stranding distributes bending stress across thousands of microscopic copper wires, reducing fatigue per wire to near-zero levels and enabling the cable to survive millions of bending cycles without conductor failure.

Polyolefin Insulation: Why Not Rubber?

The (SMK)-V-FO uses polyolefin insulation — the only cable in this entire guide series that does not use rubber (EPR) or cross-linked elastomer for conductor insulation. Polyolefin is a thermoplastic material that achieves significantly thinner insulation walls than thermoset rubber at equivalent voltage rating. For a 2.5 mm² conductor at 0.6/1 kV, polyolefin insulation can be as thin as 0.5–0.6 mm — compared to 0.8–1.0 mm for EPR 3GI3. This wall thickness reduction, multiplied across 56 cores, saves approximately 5–8 mm of total cable diameter — the critical engineering reason why 56 copper cores + fiber optic tubes can fit within just 44.3 mm OD.

This compact diameter has direct operational consequences. A smaller OD means: more cable per drum layer (fewer layers needed for the same cable length), lower cable weight per metre (less gravitational load on the aramide core during vertical suspension), and tighter bending radius (4×OD = 177 mm vs. 4×OD = 200+ mm if EPR were used). The trade-off: polyolefin has slightly lower mechanical toughness than cross-linked EPR and is more susceptible to cut-through damage during installation. The PCP rubber inner and outer sheaths compensate for this by providing the mechanical protection that the polyolefin insulation does not.

Aramide Self-Supporting + 4×OD Moving: The “-V” Advantage

The “-V” in the cable designation stands for Vertical — indicating the aramide (Kevlar®-type) self-supporting element that carries the cable’s gravitational load during vertical suspension between the trolley-mounted reel and the spreader below. This aramide core is the critical structural element that distinguishes the (SMK)-V-FO from all the horizontal Trommelflex and Cordaflex SMRT cables (which use plastic/textile central fillers without load-bearing capability).

The 4×OD moving bending radius is the tightest dynamic bending specification of any vertical cable in this guide — tighter than TRATOSLIGHT-VR (8×OD), TRATOSLIGHT-VRDB (7×OD), and URSUS VS PLUS (per VDE 0298-3). Combined with the 240 m/min spreader speed, this enables the cable to operate on compact vertical reel drums with small core diameters — critical for the space-constrained reel assemblies mounted on modern STS crane trolley structures where every millimetre of clearance matters.

How Class FS + Polyolefin Enables 4×OD

The 4×OD moving bending radius is only achievable because of the synergy between Class FS conductors (which flex with negligible internal stress), polyolefin insulation (which is more compliant than rigid cross-linked EPR at tight radii), and the aramide-centred cable geometry (which places the bending-neutral axis at the cable’s structural core). If any one of these three elements were substituted with a standard alternative (Class 5 conductors, EPR insulation, plastic filler), the achievable moving bending radius would increase to 5×OD or larger — and the cable would no longer fit the reel drums designed for 4×OD operation.

Fiber Architecture: 6 Different Tube Arrangements

The (SMK)-V-FO offers six distinct fiber tube arrangements — the most varied fiber architecture of any cable in this guide:

Fiber Tube Arrangement Options
ArrangementTotal FibersTube ConfigTypical Application
1×(6G50)6Single tube, 6 fibersBasic SCADA + 1 video channel.
1×(8G62.5)8Single tube, 8 fibersLegacy multimode, moderate data.
3×(2E9 or 2G50 or 2G62.5)63 tubes × 2 fibers eachRedundant dual-fiber channels for safety-critical communication.
3×(3E9 or 3G50 or 3G62.5)93 tubes × 3 fibers eachSCADA + video + sensor data, distributed across protected tubes.
4×(3G62.5)124 tubes × 3 fibers eachMaximum fiber count — full automation with HD video + SCADA + spare.
3×(3G50)93 tubes × 3 fibers eachModern multimode infrastructure. Balanced protection + capacity.

The multi-tube arrangements (3× or 4× tubes) distribute fibers across multiple physically separated tubes within the cable cross-section. If one tube is damaged during a mechanical event, the fibers in the remaining tubes continue operating — providing inherent redundancy that single-tube arrangements cannot offer. For safety-critical spreader applications where fiber failure could halt crane operations, the 3× or 4× tube arrangements are strongly recommended.

Where This Cable Fits: The Automated Spreader Ecosystem

The (SMK)-V-FO occupies a specific and critical position in the STS crane cable ecosystem. It is the vertical spreader control + data cable that hangs from the trolley-mounted reel to the spreader headblock — carrying all the signals and data that the spreader needs to operate:

The 44–56 copper cores at 2.5 mm² carry: twist-lock motor power (8–12 cores), flap actuator control (4–8 cores), trim and list servo signals (4–6 cores), sensor and interlock circuits (8–12 cores), camera power (4–6 cores), lighting and auxiliary power (4–6 cores), and spare cores for future expansion (4–12 cores). The 6–12 optical fibers carry: SCADA Ethernet for real-time spreader control, HD video from multiple cameras (OCR, container positioning, damage detection), high-speed sensor telemetry, and safety-critical interlock communication.

This cable works alongside (not instead of) the main power reeling cables: an URSUS VS or Cordaflex SMRT power cable on the main power reel delivers hundreds of amperes to the hoist motor, while the (SMK)-V-FO on the spreader reel delivers the intelligence that tells the spreader what to do. Together, they form the complete electrical and data backbone of an automated STS crane.

Cost-Effective Alternative from Feichun

Feichun Lead Times: 8–12 weeks. European (Klaus Faber/Prysmian): 24–34 weeks (this is one of the longest-lead items due to Class FS conductors and custom fiber tube arrangements).

Automated Terminal Savings

Real Procurement Scenario: A terminal operator upgrading 12 STS cranes to automated spreader operation needed (SMK)-V-FO equivalent cable (56×2.5 + 3×(3E9/125)) totalling 1,200 metres. Klaus Faber quoted €216,000 with 28-week lead time. Feichun quoted €115,000 with 11-week lead time. Class FS conductor flexibility verified by 4×OD bending test (zero conductor failure after 50,000 cycles); OTDR fiber testing at 1310/1550 nm confirmed all fibers within ITU-T specification; aramide tensile verified for the specific 80 m vertical drop; polyolefin insulation tested at 3.5 kV AC withstand. Total savings: €101,000 with 17 weeks earlier delivery — enabling the automated spreader upgrade to be completed before the peak shipping season.

Technical FAQ

Why polyolefin insulation instead of EPR 3GI3?

The (SMK)-V-FO must fit 56 copper cores + fiber optic tubes + aramide core into 44.3 mm OD while maintaining 4×OD dynamic bending. EPR 3GI3 insulation at standard wall thickness would increase the OD to approximately 50–52 mm — too large for the target reel drums and bending radii. Polyolefin’s thinner wall (0.5–0.6 mm vs. 0.8–1.0 mm for EPR) provides the dimensional savings needed. The PCP rubber inner and outer sheaths protect the polyolefin from mechanical damage that would compromise its thinner profile.

What is “PCP” in the sheath description?

PCP = polychloroprene — the chemical name for neoprene rubber. The datasheet describes the inner and outer sheaths as “rubber compound based on PCP” rather than using the 5GM3/5GM5 grade designation. This indicates a polychloroprene compound that may be formulated differently from the standard DIN VDE 0207-21 grades to optimise for the (SMK)-V-FO’s specific requirements (flexibility at 4×OD, compatibility with polyolefin insulation, and UV resistance for yellow-pigmented outdoor exposure).

Can I replace a TRATOSLIGHT-VRDB-FO with this cable?

The applications overlap but the cables are fundamentally different. TRATOSLIGHT-VRDB-FO uses cross-linked elastomer insulation, Class 6 conductors, and a 7×OD moving bend — while the (SMK)-V-FO uses polyolefin insulation, Class FS conductors, and a 4×OD moving bend. If your existing reel drum is designed for 7×OD bending, the (SMK)-V-FO will work with margin. However, the polyolefin insulation requires more careful termination techniques (no hot-knife stripping). Consult Feichun’s engineering team before cross-substitution.

Why is the conductor resistance 7.98 Ω/km — same as Class 5/6 plain copper?

Class FS uses the same total copper cross-section (2.5 mm²) as Class 5 and Class 6 — the difference is in wire count and diameter, not in total copper area. Since DC resistance depends on total cross-section (not wire diameter), the 7.98 Ω/km maximum for 2.5 mm² plain copper applies equally to all flexibility classes. The (SMK)-V-FO achieves this resistance because it uses bare (not tinned) copper — tinned variants would have the higher 8.21 Ω/km resistance.

References

  1. Klaus Faber AG, PRYSMIAN Cordaflex® (N)SHTOEU (SMK)-V-FO — Product Data Sheet, dbl_nshtoeu_smk_v_fo.pdf, Issue 04/01/2026.
  2. FeiChun, TRATOSMART® FO — Interstitial Fiber Isolation & Fiber Selection. feichuncables.com
  3. FeiChun, Spreader Cable Reel Engineering Guide. feichuncables.com
  4. Prysmian Group, Low Voltage Reeling Cables. prysmian.com
  5. Eland Cables, DIN VDE 0250 Standard Cable. elandcables.com
  6. Wikipedia, Kevlar — Aramid Fiber Properties. en.wikipedia.org
  7. VDE 0250 p. 814 / EN 60811-2-1 / IEC 60228 (Class FS).

Contact Anhui Feichun Special Cable Co., Ltd. — Class FS Vertical FO Cable Specialists

Technical Specifications & Engineering[email protected]
Port & Crane Cable Procurement[email protected]
Emergency Support (24/7)+86 138 5608 5607
Technical WhatsApp & WeChat+86 138 5512 3218

This technical guide is based on Feichun’s proprietary equivalent to the PRYSMIAN Cordaflex® (N)SHTOEU (SMK)-V-FO extra heavy-duty vertical reeling cable, incorporating FC-FLX™ Class FS exceptionally fine stranded bare Tongling copper conductors, polyolefin insulation, aramide self-supporting element, synthetic braid torsion protection (±50°/m), rubber compound based on PCP (inner + outer sheath), and integrated fiber optic elements. Original data from Klaus Faber AG datasheet dbl_nshtoeu_smk_v_fo.pdf, Issue 04/01/2026. Specifications subject to change. FC-FLX™ is a trademark of Anhui Feichun Special Cable Co., Ltd. Cordaflex® is a registered trademark of Prysmian Group. © 2026 Anhui Feichun Special Cable Co., Ltd. All rights reserved.

Previous Article

PRYSMIAN Cordaflex® SMRT (N)SHTOEU

Next Article

SPREADERFLEX REEL XPRT (N)SHTOEU

Write a Comment