Can (N)TSCGEWÖU cables be used for “Vertical Drum Reeling” (e.g., Spreader) without modification?

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
Engineering FAQ: Can (N)TSCGEWÖU cables be used for “Vertical Drum Reeling” (e.g., Spreader) without modification?

Engineering Inquiry: Can (N)TSCGEWÖU cables be used for “Vertical Drum Reeling” (e.g., Spreader) without modification?

Published by: Anhui Feichun Special Cable Co., Ltd.
Specialists in High-Tensile Cabling Solutions

1. Executive Summary: The Risk of Gravity

The short answer is: Only for very limited lengths and speeds. For typical industrial Spreader or Vertical Lift applications, standard (N)TSCGEWÖU cables are NOT recommended without modification. While (N)TSCGEWÖU is designed for high dynamic stress, it is primarily optimized for horizontal reeling where the cable weight is supported by the ground or rollers. In vertical applications, the entire weight of the suspended cable (plus acceleration forces) hangs directly on the copper conductors. Without a dedicated tensile support element (like Aramid or Steel), this often exceeds the VDE Safety Limit of 15 N/mm², leading to conductor elongation, breakage, and “corkscrewing.” 简短的回答是:仅适用于非常有限的长度和速度。 对于典型的工业吊具或垂直升降应用,不推荐使用未经修改的标准 (N)TSCGEWÖU 电缆。虽然 (N)TSCGEWÖU 专为高动态应力设计,但它主要针对水平卷绕进行了优化,此时电缆重量由地面或滚轮支撑。在垂直应用中,悬挂电缆的全部重量(加上加速度力)直接悬挂在铜导体上。如果没有专用的拉伸支撑元件(如芳纶或钢),这通常会超过 15 N/mm² 的 VDE 安全极限,导致导体伸长、断裂和“螺旋变形”。

2. Physics of Failure: Horizontal vs. Vertical

Horizontal Reeling (Standard Use)

In a standard gantry crane application, the cable lays on the ground. The Reel Motor only needs to pull enough tension to lift the cable off the ground and wrap it. The tensile load is relatively low.

在标准的门式起重机应用中,电缆铺设在地面上。卷盘电机只需拉动足够的张力将电缆从地面提起并卷绕。拉伸负荷相对较低。

Vertical Reeling (Spreader Use)

In a Spreader application, the cable hangs vertically.
Tensile Force ($F_t$) = Weight of Cable ($m \times g$) + Acceleration Force ($m \times a$).
Standard copper conductors have a low yield strength. If the calculated tension exceeds 20 N/mm² (Total Copper Cross-Section), the copper begins to stretch permanently (plastic deformation). This stretches the copper inside the rubber sheath, causing the cable to twist and deform (Corkscrew) as the excess copper tries to find space.

在吊具应用中,电缆垂直悬挂。
拉力 ($F_t$) = 电缆重量 ($m \times g$) + 加速度力 ($m \times a$)。
标准铜导体的屈服强度较低。如果计算出的张力超过 20 N/mm²(总铜截面积),铜开始发生永久伸长(塑性变形)。这会在橡胶护套内部拉伸铜,随着多余的铜试图寻找空间,导致电缆扭曲变形(螺旋变形)。

3. When is Modification Required? (Calculation Rule)

You can use standard (N)TSCGEWÖU IF AND ONLY IF the tensile load is low.

Parameter (参数)Standard (N)TSCGEWÖU
(No Modification)
Modified (N)TSCGEWÖU-V / (N)TSZCGEWÖU
(With Strain Relief)
Max Tensile Stress
最大拉伸应力
< 15 N/mm²
(Safe Limit)
< 15 N/mm²
(安全极限)
> 20 N/mm²
(Requires Support)
> 20 N/mm²
(需要支撑)
Typical Vertical Length
典型垂直长度
Max 30-50 Meters
(Depending on cable weight)
最大 30-50 米
(取决于电缆重量)
Up to 200+ Meters
(Load carried by Aramid/Steel)
高达 200+ 米
(由芳纶/钢承受负载)
Acceleration
加速度
Low (< 0.5 m/s²)
低 (< 0.5 m/s²)
High (> 1.0 m/s²)
高 (> 1.0 m/s²)
CRITICAL: If your calculation shows tension > 15 N/mm², you MUST use a cable with a Central Strain Relief Member (usually designated with “-V” or “Z”).
关键提示:如果您的计算显示张力 > 15 N/mm²,您必须使用带有中央应力消除构件的电缆(通常标记为“-V”或“Z”)。

4. The Anhui Feichun Solution: (N)TSZCGEWÖU

To handle vertical spreader applications safely, Anhui Feichun manufactures a modified version often coded as (N)TSZCGEWÖU (where “Z” stands for Zugentlastung – Strain Relief).
This cable features a Central Aramid (Kevlar) Core. The Aramid fibers have a tensile strength 5x higher than steel by weight. The entire weight of the cable is clamped to this central core at the termination points, leaving the sensitive copper conductors completely stress-free.
为了安全地处理垂直吊具应用,安徽飞纯生产一种改进版本,通常编码为 (N)TSZCGEWÖU(其中“Z”代表 Zugentlastung – 应力消除)。
该电缆具有中央芳纶 (Kevlar) 芯。芳纶纤维的单位重量抗拉强度是钢的 5 倍。电缆的全部重量在终端点被夹紧到这个中心芯上,使敏感的铜导体完全没有应力。
  • Reduced Diameter: Aramid allows us to keep the cable compact compared to steel ropes.
  • Torsion Free: The central element prevents the cable from spinning under load.

Contact Anhui Feichun Special Cable Co., Ltd.

Free Tensile Load Calculation for Your Vertical Application

Technical Engineering Dept. [email protected]
International Sales (Zihao Yang) [email protected]
International Sales (Ziyu Huang) [email protected]
WhatsApp / 24h Support +86 13855123218
Previous Article

What is the difference between a "Festoon" cable application and a "Reeling" application under VDE selection guidelines?

Next Article

What specific VDE cable type is recommended for use in water (submersible pumps) up to 100 meters depth?

Write a Comment

Leave a Comment

您的邮箱地址不会被公开。 必填项已用 * 标注