ÖLFLEX® CLASSIC 110 BK — черный VDE-регистрированный маслостойкий ПВХ кабель управления 300/500 V

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
ÖLFLEX® CLASSIC 110 BK — черный VDE маслостойкий ПВХ кабель управления 300/500 V
ÖLFLEX® CLASSIC110 BKVDE 7030RAL 9005UV resistantTM54 oil resistant

ÖLFLEX® CLASSIC 110 BK — черный VDE-регистрированный маслостойкий ПВХ кабель управления 300/500 V

PVC control cable with black outer sheath for a wide range of applications: outdoor use, oil resistance, numbered cores, WTG torsion, short power chains and industrial control wiring.

ÖLFLEX® CLASSIC 110 BK — универсальный гибкий кабель управления с черной ПВХ оболочкой RAL 9005, нумерованными жилами и VDE certificate of conformity with factory surveillance. Серия предназначена для фиксированной прокладки, периодического свободного изгибания без растягивающей нагрузки, сухих и влажных помещений со средними механическими нагрузками, а также для наружных применений благодаря UV and weather resistance.

Кабель сочетает классическую конструкцию LAPP control cable с расширенными эксплуатационными свойствами: oil-resistant according to DIN EN 50290-2-22 TM54, flame-retardant according IEC 60332-1-2, torsion movement in WTG TW-0 & TW-1 и возможность применения в power chains на расстояние перемещения до 5 m и 0.2 … 1 million bending cycles для размеров 0.5–2.5 mm² и 2–7 conductors.

✓ Black PVC outer sheath RAL 9005✓ Outdoor applications✓ UV and weather-resistant ISO 4892-2✓ Oil-resistant TM54✓ VDE reg. no. 7030✓ Numbered cores VDE 0293-334✓ U0/U 300/500 V✓ 4000 V test voltage✓ WTG TW-0 & TW-1
Product type
Control cable
ETIM EC000104
Nominal voltage
300/500 V
U0/U for industrial control circuits
Approval
VDE 7030
defined size ranges
Outer sheath
RAL 9005
black PVC, UV-resistant
Bending radius
10×D
occasional flexing
Range
52 items
0.75 to 16.0 mm² in provided list

1. Позиционирование и ключевые преимущества

Серия ÖLFLEX CLASSIC 110 BK закрывает потребность в универсальном черном кабеле управления для промышленности, где требуются VDE-статус, нумерованные жилы, маслостойкость, химическая стойкость и пригодность к наружному применению. Индекс BK важен для SEO и закупочных запросов: он указывает на черную наружную оболочку, близкую к RAL 9005, и отличает серию от серой ÖLFLEX CLASSIC 110.

Recommended catalog description: ÖLFLEX CLASSIC 110 BK is a VDE-registered oil-resistant black PVC control cable with numbered cores for fixed installation, occasional flexing, outdoor applications, WTG torsion and short power-chain use in industrial machinery and control systems.

2. CAD-style engineering section drawing

CAD-style section A-A · ÖLFLEX CLASSIC 110 BK · vertical engineering drawing · black UV-resistant oil-resistant PVC control cable
101 202 303 404 PEGN Ø 5,4–21,2 mm 6 5 4 3 1 2 FEICHUN CABLES — SECTION A-A · VERTICAL LAYOUT ÖLFLEX CLASSIC 110 BK · VDE CONTROL CABLE · BLACK PVC Oil-resistant TM54 · UV/weather resistant ISO 4892-2 DWG FC-OLF-110BK-01V · Rev 02 Representative OD range: 5.4–21.2 mm Scale NTS Class 5 copper · 300/500 V

The CAD drawing is reformatted as a vertical engineering illustration better suited to narrower website layouts. It still shows the same technical logic: a black PVC outer sheath, oil-resistant PVC construction, layered twisted numbered cores and an optional GN-YE protective conductor for G versions.

Pos.ElementMaterial / specification
1Fine-wire conductorBare copper wires, class 5 according to DIN EN 60228 / IEC 60228
2PVC insulationLAPP P8/1, black cores with white numbers according to VDE 0293-334
3Protective conductorG versions include GN-YE protective conductor; X versions are manufactured without protective conductor
4Layered core lay-upCores twisted in layers for flexible control-cable construction and stable geometry during installation
5Functional PVC sheathOil-resistant according to DIN EN 50290-2-22 TM54; flame-retardant according to IEC 60332-1-2
6Outer sheathBlack PVC outer sheath, RAL 9005, UV- and weather-resistant according to ISO 4892-2
Representative range from the provided BK data: 0.75–16.0 mm² · 2 to 34 cores in the listed selection · outer diameter 5.4–21.2 mm · copper index 14.4–768 kg/km · weight 45–1370 kg/km.
Why the vertical format works better: the drawing, explanatory table and legend now flow in a top-to-bottom reading order, so the CAD figure remains readable on narrower content columns without creating an overly wide horizontal block on the website.
Black PVC outer sheath RAL 9005
PVC insulation and numbered cores
Bare copper fine-wire conductors
GN-YE protective conductor in G versions

3. Product make-up

1. Fine-wire copper conductor
Fine-wire strand made of bare copper wires. Conductor stranding follows DIN EN 60228 / VDE 0295 class 5 and IEC 60228 class 5.
2. PVC insulation LAPP P8/1
Black cores with white numbers according to VDE 0293-334. This core identification is optimized for control cabinets, terminal blocks and industrial troubleshooting.
3. Layered core twisting
Cores are twisted in layers, supporting a broad conductor count range while maintaining a familiar control-cable layout.
4. Black PVC outer sheath
The black outer sheath, similar to RAL 9005, is UV and weather-resistant according to ISO 4892-2 and suitable for outdoor applications.

4. Technical data

ParameterValue
Product typeVDE-registered oil-resistant PVC control cable with black outer sheath
ETIM 5.0/6.0Class-ID: EC000104; Class-Description: Control cable
Core identificationBlack with white numbers acc. to VDE 0293-334
Conductor strandingFine wire according to DIN EN 60228 / VDE 0295 class 5 / IEC 60228 class 5
Outer sheathPVC outer sheath, black, similar RAL 9005
Flame retardanceFlame-retardant according IEC 60332-1-2
Chemical resistanceGood chemical resistance, see catalogue appendix T1
Oil resistanceAccording to DIN EN 50290-2-22 TM54
UV and weather resistanceAccording to ISO 4892-2
Norm references / approvalsVDE reg. no. 7030 for defined size ranges
VDE size coverageUp to 2.5 mm²: 2–65 cores; from 4 mm²: 2–7 cores; from 25 mm²: 2–5 cores
Torsion movement in WTGTW-0 & TW-1, refer to Appendix T0
Minimum bending radiusOccasional flexing: 10 x outer diameter; in power chains: 15 x outer diameter; fixed installation: 4 x outer diameter
Nominal voltageU0/U: 300/500 V
Test voltage4000 V
Protective conductorG = with GN-YE protective conductor; X = without protective conductor
Temperature rangeOccasional flexing: -15 °C to +70 °C; in power chains: -5 °C to +70 °C; fixed installation: -40 °C to +80 °C

5. Application range

Outdoor applications

Black PVC sheath with UV and weather resistance according to ISO 4892-2 makes the cable suitable for outdoor use.

Industrial machinery

Numbered cores and flexible class 5 conductors support wiring in machines, control systems and automation equipment.

Dry or damp rooms

The cable is designed for dry or damp rooms subject to medium mechanical loads.

WTG torsion

Suitable for torsional applications typical for the loop in wind turbine generators, TW-0 & TW-1.

Power chains

For travelling distance up to 5 m and 0.2 … 1 million bending cycles for dimensions 0.5 to 2.5 mm² and 2 to 7 conductors.

Control cabinets

Black numbered cores simplify installation, service, circuit identification and terminal documentation.

6. Product range in provided data

0.75 mm²

11 позиций: от 2 X 0.75 до 34 G 0.75. Наружный диаметр 5.4–15.9 mm.

1.0 mm²

12 позиций: от 2 X 1.0 до 34 G 1.0. Наружный диаметр 5.7–17.1 mm.

1.5 mm²

12 позиций: от 2 X 1.5 до 25 G 1.5. Наружный диаметр 6.3–16.9 mm.

2.5 mm²

8 позиций: от 2 X 2.5 до 25 G 2.5. Наружный диаметр 7.5–20.8 mm.

4.0 mm²

3 позиций: от 3 G 4.0 до 5 G 4.0. Наружный диаметр 9.9–12.1 mm.

6.0 mm²

2 позиций: от 4 G 6.0 до 5 G 6.0. Наружный диаметр 13.0–14.5 mm.

10.0 mm²

2 позиций: от 4 G 10.0 до 5 G 10.0. Наружный диаметр 16.2–18.1 mm.

16.0 mm²

2 позиций: от 4 G 16.0 до 5 G 16.0. Наружный диаметр 18.8–21.2 mm.

Article numberNumber of cores and mm² per conductorOuter diameter [mm]Copper index [kg/km]Weight [kg/km]
11198092 X 0.755.414.445
11198713 G 0.755.721.655
11198923 X 0.755.721.655
11198724 G 0.756.228.866
11198934 X 0.756.228.866
11198735 G 0.756.73679
11198747 G 0.757.350.4101
111987512 G 0.759.986.4171
111987618 G 0.7511.7130244
111987725 G 0.7513.8180337
111987834 G 0.7515.9245448
11198942 X 1.05.719.253
11192443 G 1.06.028.865
11198953 X 1.06.028.865
11192454 G 1.06.538.479
11198964 X 1.06.538.479
11192465 G 1.07.14894
11198975 X 1.07.14894
11192477 G 1.08.067.2126
111924812 G 1.010.5115205
111924918 G 1.012.7173290
111925125 G 1.014.7240390
111925234 G 1.017.1326551
11198982 X 1.56.328.868
11190203 G 1.56.743.284
11198993 X 1.56.743.284
11198794 G 1.57.257.6104
11199004 X 1.57.257.6104
11198805 G 1.58.172128
11199115 X 1.58.172128
11198817 G 1.58.9101166
11199137 X 1.58.9101166
111988212 G 1.512.0173279
111988318 G 1.514.4259407
111988425 G 1.516.9360560
11199142 X 2.57.548100
11198853 G 2.58.172132
11198864 G 2.58.996163
11198875 G 2.510.0120200
11198887 G 2.511.1168267
111988912 G 2.514.8288444
111989018 G 2.517.8432648
111989125 G 2.520.8600890
11199153 G 4.09.9115.2201
11199164 G 4.010.8154249
11199175 G 4.012.1192315
11199184 G 6.013.0230365
11199195 G 6.014.5288447
11199204 G 10.016.2384590
11199215 G 10.018.1480722
11199224 G 16.018.86141087
11199235 G 16.021.27681370

Unless specified otherwise, shown product values are nominal values. Detailed values, including tolerances, are available upon request. Copper price basis: EUR 150/100 kg. Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum. Please specify the preferred type of packaging, for example 1 x 500 m drum or 5 x 100 m coils. Photographs and graphics are not to scale and do not represent detailed images of the respective products.

7. SEO block for Russian-language product pages

Recommended search phrases: ÖLFLEX CLASSIC 110 BK, черный кабель управления ПВХ, VDE кабель управления, маслостойкий кабель управления, кабель управления 300/500 В, кабель с нумерованными жилами, UV resistant control cable, black PVC control cable, кабель для наружной прокладки, кабель для ветроустановок, WTG torsion cable, кабель для энергоцепей, flame retardant PVC cable, industrial control cable.

8. Selection guidance

Selection criterionRecommended checkEngineering meaning
Outdoor useConfirm need for black UV and weather-resistant sheath according to ISO 4892-2BK version is preferable when a black outdoor-suitable sheath is required.
Oil exposureOil resistance according to DIN EN 50290-2-22 TM54Important for machinery, production lines and industrial environments with oil contact.
Moving useOccasional flexing only; power chains only within listed limitsNot a universal drag-chain cable; check travel distance, cycles, conductor count and section.
WTG torsionTW-0 & TW-1 suitabilityCan be selected for torsion typical of the loop in wind turbine generators.
Core identificationBlack cores with white numbers according to VDE 0293-334Best for control wiring requiring clear conductor numbering.
VDE coverageVDE reg. no. 7030 applies to defined size rangesCheck the selected conductor count and cross-section against the stated VDE coverage.

9. FAQ

What does BK mean in ÖLFLEX CLASSIC 110 BK?

BK refers to the black outer sheath. In this series the PVC outer sheath is black, similar to RAL 9005, and UV-resistant.

Is the cable suitable for outdoor applications?

Yes. The provided data states that the cable is suitable for outdoor applications and UV and weather-resistant according to ISO 4892-2.

Is ÖLFLEX CLASSIC 110 BK oil-resistant?

Yes. Product features specify oil resistance according to DIN EN 50290-2-22, TM54.

Can the cable be used in power chains?

Yes, under restricted conditions: travelling distance up to 5 m and 0.2 … 1 million bending cycles for dimensions 0.5 to 2.5 mm² and 2 to 7 conductors.

What is the nominal voltage?

The nominal voltage is U0/U 300/500 V, with test voltage 4000 V.

How are the cores identified?

The cores are black with white numbers according to VDE 0293-334. G versions include a GN-YE protective conductor, while X versions do not.

10. Detailed engineering interpretation

Control-circuit cable, not a medium-voltage power cable

With U0/U 300/500 V and 4000 V test voltage, ÖLFLEX CLASSIC 110 BK is positioned as a control cable for signalling, control, auxiliary power and machine wiring circuits. It should not be described as a 0.6/1 kV power cable.

Flexible, but not permanently dynamic

The cable supports fixed installation and occasional flexing at free, non-continuously recurring movement without tensile load. For constantly moving systems, the power-chain statement is limited to the stated short travel and cycle range.

Black sheath for UV-exposed applications

The BK version has a black PVC outer sheath, similar to RAL 9005. The provided data states suitability for outdoor applications and UV/weather resistance according to ISO 4892-2.

TM54 oil-resistant PVC sheath

Oil resistance according to DIN EN 50290-2-22 TM54 is a central keyword for industrial use near machine tools, lubricants and oil-containing production environments.

11. Layer function and failure-prevention logic

Layer or design featureFunction in the cablePractical benefitSEO / catalog wording
Fine-wire bare copper conductorClass 5 conductor construction for flexible wiring.Easier routing in cabinets, machines and compact installation spaces.fine-wire copper conductor, flexible control cable, class 5 cable
PVC insulation LAPP P8/1Electrical insulation around each numbered core.Supports reliable control-circuit separation in multi-core layouts.PVC insulated control cable, numbered-core cable
Layer-twisted coresCores twisted in layers to form a stable cable make-up.Supports roundness, routing stability and predictable outer diameter.layer twisted cores, industrial control wiring
Black PVC outer sheathMechanical protection and environmental outer barrier.Useful for outdoor, UV-exposed and black-sheath specification projects.black PVC sheath, RAL 9005, UV resistant cable
Numbered coresBlack cores with white numbers acc. to VDE 0293-334.Reduces wiring confusion and improves service traceability.numbered cores, black cores with white numbers
GN-YE protective conductor in G versionsIntegrated protective conductor when required.Allows direct selection between G and X versions depending on circuit design.G version with protective conductor, X version without PE

12. Application suitability matrix

Application scenarioSuitabilityWhy it fitsImportant limitation
Control cabinets and terminal boxesStrong fitNumbered cores, many core counts and class 5 conductors support dense wiring.Observe bending radius and avoid tensile load during occasional movement.
Industrial machineryStrong fitOil resistance, chemical resistance and medium mechanical-load suitability are relevant for machine environments.For continuous drag-chain motion, select only within the stated power-chain limit or choose a dedicated chain cable.
Outdoor control wiringStrong fitBlack UV/weather-resistant sheath according to ISO 4892-2 and suitability for outdoor applications.Installation details such as water accumulation, fixing method and mechanical protection remain project-dependent.
Wind turbine generator loopConditional fitSuitable for torsional applications typical for the loop in wind turbine generators, TW-0 & TW-1.Check torsion class, routing radius, fixation and service profile before final selection.
Short power chainsConditional fitAllowed for travel distance up to 5 m and 0.2 … 1 million bending cycles for 0.5 to 2.5 mm² and 2 to 7 conductors.Not a universal high-cycle drag-chain cable; use the exact size and motion limits.
Wet or damp indoor areasSuitableDry or damp rooms subject to medium mechanical loads are included in the application range.Not a substitute for submersible, high-pressure washdown or permanently water-exposed cable without additional assessment.

13. Power-chain and torsion notes for technical buyers

Power-chain boundary

The provided data allows use in power chains only for a travelling distance up to 5 m and 0.2 … 1 million bending cycles, and only for dimensions 0.5 to 2.5 mm² with 2 to 7 conductors. This statement should be kept precise in web copy, because overstating drag-chain performance may lead to wrong cable selection.

up to 5 m travel0.2 … 1 million cycles0.5–2.5 mm²2–7 conductors

WTG torsion boundary

The cable is suitable for torsional applications typical for the loop in wind turbine generators. The stated torsion reference is TW-0 & TW-1. For SEO, this should be written as WTG torsion control cable, torsion-suitable PVC control cable and wind turbine loop cable.

WTG loopTW-0 & TW-1torsion-suitablecontrol cable

14. VDE 7030 coverage explained

The VDE registration is an important trust signal for procurement and engineering departments. The provided VDE reg. no. 7030 applies to defined size ranges, so a product page should not simply imply unlimited VDE coverage for every possible configuration.

Cross-section rangeCovered core-count range stated in the dataCatalog interpretation
up to 2.5 mm²2 – 65 coresMain high-variety control-cable range with broad VDE coverage.
from 4 mm²2 – 7 coresHigher cross-sections are available with narrower core-count coverage.
from 25 mm²2 – 5 coresLarge conductor sizes should be checked carefully against the selected article.

15. Selection workflow for procurement pages

Step 1 — Choose G or X

Use G when a GN-YE protective conductor is required. Use X when the circuit design does not require a protective conductor inside the cable.

Step 2 — Define core count

Select the number of control, signal and auxiliary cores. For service-friendly wiring, keep spare-core strategy in mind.

Step 3 — Select cross-section

Choose conductor cross-section according to current, voltage drop, terminal compatibility and mechanical cable diameter.

Step 4 — Confirm motion profile

Separate fixed installation, occasional flexing, WTG torsion and short power-chain use. Each profile has a different bending-radius or cycle boundary.

Step 5 — Check environment

Use BK when black sheath, outdoor performance, UV/weather resistance and oil resistance are relevant to the project.

Step 6 — Specify packaging

Packaging size is coil ≤ 30 kg or ≤ 250 m, otherwise drum. State the preferred packaging, for example 1 x 500 m drum or 5 x 100 m coils.

16. Recommended long-tail SEO keyword clusters

Keyword clusterRussian search phrasesEnglish / mixed technical phrasesBest page section
Core productÖLFLEX CLASSIC 110 BK, кабель управления ÖLFLEX 110 BKOLFLEX CLASSIC 110 BK PVC control cableHero, product title, meta title
Black outdoor sheathчерный кабель управления, кабель управления для наружной прокладкиblack PVC control cable, UV resistant control cableBenefits, outdoor applications
Oil resistanceмаслостойкий кабель управления, кабель TM54oil-resistant PVC control cable, DIN EN 50290-2-22 TM54Product features, FAQ
Industrial machineryкабель для станков, кабель для промышленного оборудованияindustrial machinery control cable, machine tool cableApplication range
Motion-specificкабель для энергоцепей, кабель для ветроустановокshort power-chain cable, WTG torsion cablePower-chain and torsion notes
Identificationкабель с нумерованными жилами, черные жилы с белыми номерамиnumbered cores control cable, VDE 0293-334Construction and selection workflow

17. Extended FAQ for sales and technical support

Can ÖLFLEX CLASSIC 110 BK replace a dedicated drag-chain cable?

Only in the restricted case stated in the product data: power chains with travelling distance up to 5 m and 0.2 … 1 million bending cycles, for 0.5 to 2.5 mm² and 2 to 7 conductors. For longer travel, higher cycles or continuous dynamic motion, a dedicated chain cable should be considered.

Why is the black sheath important?

The black sheath, similar to RAL 9005, supports the BK positioning and is connected with outdoor suitability and UV/weather resistance according to ISO 4892-2. It also makes the cable easier to specify in projects requiring a black outer jacket.

What is the difference between oil resistance and chemical resistance?

Oil resistance is specifically stated according to DIN EN 50290-2-22 TM54. Chemical resistance is described as good, with reference to catalogue appendix T1. In technical communication, these should be kept as two related but separate properties.

How should the cable be described for outdoor control systems?

A suitable wording is: black oil-resistant PVC control cable with numbered cores, UV and weather resistance according to ISO 4892-2, suitable for outdoor applications and fixed or occasionally flexing installation.

What should be checked before ordering high-core-count variants?

Check article number, conductor count, conductor cross-section, outer diameter, copper index, weight, VDE range and packaging. High-core-count cables have larger diameters and weights, which affect routing, cable glands and handling.

18. Ready-to-use technical copy

ÖLFLEX® CLASSIC 110 BK is a VDE-registered oil-resistant PVC control cable with a black outer sheath for a wide range of industrial applications. It is designed for fixed installation and occasional flexing at free, non-continuously recurring movement without tensile load. The cable is suitable for dry or damp rooms subject to medium mechanical loads, outdoor applications, torsional applications typical for the loop in wind turbine generators and restricted short power-chain use. The power-chain statement should be applied precisely: travelling distance up to 5 m and 0.2 … 1 million bending cycles, for 0.5 to 2.5 mm² and 2 to 7 conductors. The construction includes fine-wire bare copper conductors, PVC insulation LAPP P8/1, cores twisted in layers and a black PVC outer sheath similar to RAL 9005. The cable features black cores with white numbers according to VDE 0293-334, flame retardance according to IEC 60332-1-2, good chemical resistance, oil resistance according to DIN EN 50290-2-22 TM54, UV and weather resistance according to ISO 4892-2, nominal voltage U0/U 300/500 V and test voltage 4000 V. G versions include a GN-YE protective conductor; X versions are supplied without protective conductor. Typical selection keywords include black PVC control cable, oil-resistant control cable, UV resistant control cable, numbered cores control cable, VDE 7030 control cable, WTG torsion cable and industrial machinery control cable.

ÖLFLEX® CLASSIC 110 BK · Black PVC control cable · VDE 7030 · Oil-resistant · UV-resistant

Professional Russian SEO product page for a VDE-registered oil-resistant PVC control cable with black RAL 9005 PVC outer sheath, numbered cores, VDE 7030 coverage, TM54 oil resistance, ISO 4892-2 UV/weather resistance, 300/500 V nominal voltage, WTG torsion suitability, short power-chain use and detailed engineering selection notes.

Feichun Cables · Feichun Cable

Tel: +86 13855123218 · Email: [email protected]

Document ID: FEICHUN-OLFLEX-CLASSIC-110-BK-DETAILED-SEO-RU · black PVC control cable · VDE 7030 · TM54 oil-resistant · UV-resistant
Previous Article

ÖLFLEX® CLASSIC 110 BK — черный VDE-регистрированный маслостойкий ПВХ кабель управления 300/500 V

Next Article

ÖLFLEX® CLASSIC 110 LT — холодостойкий ПВХ кабель управления для низких температур и наружного применения