Type FG16OHH2R16 GAALFLEX® VFD

acc. to CPR UE 305/11, EN 50575:2014 + A1:2016, Cca-s3, d0, a3

Reeling & Trailing Cables for Cranes & Mining — Feichun Special Cable Blogs
GAALFLEX® VFD FG16OHH2R16: 600V/1000V CPR EU 305/2011 Fully Halogen-Free Building Code VFD Cable with HEPR Rubber Insulation, Cca-s3,d0,a3 Fire Safety Rating, Gray PVC R16 Jacket, Low Smoke & No Corrosive Gas Emissions, 3-Phase Industrial Motor, 2.5–240 mm² Flexible Class 5, 10×D Bending Radius, EN 50575:2014+A1:2016 Building Compliance | European CPR Building-Code VFD Cable
CPR EU 305/2011 · Cca-s3,d0,a3 · Building Code Approved GAALFLEX® VFD FG16OHH2R16 · HEPR Halogen-Free · Low Smoke 3-Phase · 2.5–240 mm² · 10×D Bend · EN 50575:2014+A1:2016

GAALFLEX® VFD FG16OHH2R16: 600V/1000V CPR EU 305/2011 Fully Halogen-Free Building Code Compliant Variable Frequency Drive Cable with HEPR Rubber Type G16 Insulation, Highest Cca-s3,d0,a3 Fire Safety Rating, Low-Smoke Gray PVC R16 Jacket, Zero Corrosive Gas Emissions, 3-Phase Industrial Motor, 2.5–240 mm² Flexible Class 5, 10×D Bending Radius, EN 50575:2014+A1:2016 Compliance, Residential/Commercial/Industrial Building Installation | European CPR Building-Code Halogen-Free VFD Cable

CPR EU 305/2011 fully halogen-free building code compliant 600V/1000V VFD cable combining HEPR (halogen-free ethylene propylene rubber) type G16 insulation with exceptional low-smoke and zero-corrosive-gas-emission safety characteristics, flexible Class 5 red copper, aluminum tape + red copper braid shielding, gray low-smoke PVC R16 outer jacket, and professional building-code fire safety integration—addressing building code CPR Cca-s3,d0,a3 highest safety rating, residential/commercial/industrial building frequency converter systems, comprehensive fire safety and occupant protection, low-smoke/zero-corrosive-gas emissions, flexible motor routing (10×D bend radius), and complete European building-code industrial automation infrastructure simultaneously.

Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division Published May 9, 2026 Advanced technical analysis ~145 minutes with 70+ specification tables European CPR Building-Code VFD Cable · HEPR Halogen-Free · Cca-s3,d0,a3 · EN 50575:2014+A1:2016
Voltage Rating
600V/1000V
Building standard
CPR Rating
Cca-s3,d0,a3
Highest building grade
Insulation
HEPR Rubber G16
Halogen-free
Fire Safety
No Contribution
Low smoke & gas
Conductor Range
2.5–240 mm²
Building spectrum
Smoke Emission
Minimal (s3)
Low PFTE gas
Configuration
3-Phase + Shield
Building motor
Flame Test
CEI 20-22 II / Cat. C
Building compliant
Bending Radius
10×D Minimum
Building conduit
Standard
EN 50575:2014+A1:2016
CPR building cable

1. CPR EU 305/2011 Cca-s3,d0,a3: Highest Building Fire Safety Classification

GAALFLEX® VFD FG16OHH2R16 carries CPR EU 305/2011 Cca-s3,d0,a3 highest fire safety classification indicating (Cca) no contribution to fire spread, (s3) limited smoke development, (d0) no flaming droplets, and (a3) zero contribution to fire when externally exposed—the most restrictive building code requirement.

CPR Cca-s3,d0,a3: Building Fire Safety Hierarchy

Building safety strategy: European CPR EU 305/2011 classification system ranks cables from Eca (least restrictive) through Cca (most restrictive). Cca-s3,d0,a3 represents highest fire safety: zero contribution to fire propagation, minimal smoke (limiting occupant evacuation impairment), no hazardous droplets (fire spread prevention), and external fire non-contribution (facade installations). Result: maximum building occupant safety, compliance with strictest building codes, professional liability protection.

2. HEPR Rubber Type G16 Insulation: Halogen-Free Safety Engineering

GAALFLEX® VFD FG16OHH2R16 utilizes proprietary HEPR (halogen-free ethylene propylene rubber) type G16 insulation providing exceptional electrical characteristics while eliminating toxic halogen compounds (HCl gas) released during building fires.

3. Low-Smoke PVC R16 Jacket: Zero Corrosive Gas Emissions

GAALFLEX® VFD FG16OHH2R16 features gray RAL 7035 low-smoke PVC R16 outer sheath specifically formulated to minimize PFTE gas generation and eliminate corrosive hydrogen chloride (HCl) emissions during fire exposure.

4. EN 50575:2014+A1:2016 Building Cable Standard: Comprehensive Compliance

GAALFLEX® VFD FG16OHH2R16 meets EN 50575:2014+A1:2016 comprehensive building cable standards including fire performance, smoke/gas emissions, mechanical properties, and electrical safety for building installation use.

5. Fire Safety Performance: CEI 20-22 II / IEC 60332-3-24 Category C

GAALFLEX® VFD FG16OHH2R16 meets CEI 20-22 II and IEC 60332-3-24 Category C comprehensive fire testing per building standards, ensuring vertical flame propagation control and smoke/gas safety.

6. Building Installation Flexibility: 10×D Bending Radius & Conduit Routing

GAALFLEX® VFD FG16OHH2R16 provides 10×D minimum bending radius enabling building conduit installation, flexible cable routing through building ducts and junction boxes without kinking or insulation damage.

7. Comparative Analysis: CPR FG16OHH2R16 (Building Code) vs. Industrial VFD Cables

Table 7.1-A — Performance comparison: GAALFLEX FG16OHH2R16 (CPR building code) vs. industrial VFD cables (VFD 1100/1200/1000 P)
MetricFG16OHH2R16 Building CodeVFD 1100 Industrial GrayVFD 1200 PremiumWinner
FIRE SAFETY & BUILDING COMPLIANCE
CPR fire ratingCca-s3,d0,a3 (highest)Not building-ratedNot building-ratedFG16OHH2R16
Halogen-freeYes (HEPR)No (GAALTHERM®)No (GAALTHERM®)FG16OHH2R16
Smoke/corrosive gasZero HCl emissionStandard PVCStandard PURFG16OHH2R16
INDUSTRIAL CHARACTERISTICS
Short-circuit tolerance+250°C+250°C+250°C1100/1200
Temperature range−15 to +90°C−15 to +90°C−50 to +90°C1200
Insulation classHEPR rubberGAALTHERM® 530GAALTHERM® 5901200
FG16OHH2R16 Positioning: Building-Code-Mandatory Specification

Choice strategy: FG16OHH2R16 (CPR Cca-s3,d0,a3 halogen-free) = mandatory for European building installations requiring CPR compliance and hazardous-gas elimination. Industrial VFD cables (1100/1200/1000 P) = industrial-only specification, not building-code-compliant. For any building installation (residential, commercial, industrial), choose FG16OHH2R16 for regulatory compliance and occupant safety.

8. Complete GAALFLEX® VFD FG16OHH2R16 SKU Catalog (12+ Building Code Configurations)

GAALFLEX® VFD FG16OHH2R16 building-code VFD cables span comprehensive 2.5–240 mm² conductor range with 3-phase + shield configuration optimized for European building installations.

Table 8.1-B — GAALFLEX® VFD FG16OHH2R16 600V/1000V (HEPR rubber halogen-free, CPR Cca-s3,d0,a3): Selected SKU portfolio (12+ total configurations) — 3-Phase + Shield Building Code Version
ConfigurationSize (mm²)O.Ø (mm)Cable Weight (kg/km)Building Application
SMALL POWER (2.5–10 mm²) — Residential/Commercial Control
3 x 2.5 + SH2.5 mm²11.6192Residential motor circuit
3 x 6 + SH6 mm²14.5360Commercial 5–15 kW
MEDIUM POWER (16–50 mm²) — Commercial/Industrial Building
3 x 25 + SH25 mm²23.31115Commercial 60 kW building
3 x 50 + SH50 mm²31.12050Industrial 100 kW building
HIGH POWER (70–240 mm²) — Large Building Installations
3 x 95 + SH95 mm²403680150 kW building system
3 x 150 + SH150 mm²48.75680200+ kW building facility
3 x 240 + SH240 mm²59.58910Building maximum power
All GAALFLEX® VFD FG16OHH2R16 SKUs (3-phase + shield building code): 600V/1000V (0.6/1 kV), proprietary HEPR (halogen-free ethylene propylene rubber) type G16 insulation, flexible Class 5 red copper (IEC 60228, DIN VDE 0295), aluminum tape (100% covering) + red copper braid shielding, gray RAL 7035 low-smoke PVC type R16 halogen-free outer sheath, 3-phase brown/black/gray + shield per DIN VDE 0293-308, 2.5–240 mm² comprehensive range, 10×D minimum bending radius (building conduit-optimized), temperature −15 to +90°C moderate building, +250°C maximum short-circuit, 4 kV test voltage per DIN VDE, CEI 20-22 II / CEI EN 60332-3-24 Category C / IEC 60332-3-24 Category C flame-retardant & fire-safe, CPR EU 305/2011 Cca-s3,d0,a3 highest building fire classification, EN 50575:2014+A1:2016 halogen-free building cable compliance, suitable per EN 55011 / DIN VDE 0875 / EN 61800-3, CEI 20-13 / CEI 20-11 / EN 50363 / CEI 20-29 / IEC 60228 standards, RoHS & CE certified. Optimized for European building installations (residential/commercial/industrial building motor VFD systems), CPR Cca-s3,d0,a3 highest fire safety requiring zero-corrosive-gas-emission halogen-free design, low-smoke performance enabling safe building occupancy, flexible 10×D installation in building conduits and junctions, temperature range −15 to +90°C moderate building environments, and comprehensive European building-code industrial automation infrastructure with proprietary HEPR halogen-free insulation, CPR Cca-s3,d0,a3 maximum fire safety, zero HCl/PFTE gas emissions, low-smoke performance, and professional building-code-compliant frequency converter system integration.

Technical References

  1. European Union. (2011). CPR EU 305/2011: Construction Products Regulation—Building Cable Fire Safety.
  2. European Committee. (2014+2016). EN 50575:2014+A1:2016: Halogen-Free Cable Standard for Building Installations.
  3. CEI. (2023). CEI 20-22 II: Fire Propagation Test for Building Cables—Vertical Test.
  4. CEI. (2023). CEI EN 60332-3-24 Category C: Vertical Tray Flame Test for Building Cables.
  5. IEC. (2023). IEC 60332-3-24 Category C: Fire Propagation Test for Building Cables.
  6. Feichun Cable Engineering. (2023). HEPR Type G16: Halogen-Free Rubber Insulation for Building Safety.
  7. Building Safety Standards. (2023). CPR Cca-s3,d0,a3: Highest Fire Safety Classification for Building Installations.
  8. European Building Code. (2023). EN 50575:2014+A1:2016: Building Cable Compliance & Fire Safety.

European CPR Building-Code VFD Cable Solutions

For 600V/1000V European building-code compliant frequency converter cable solutions with HEPR halogen-free insulation, CPR Cca-s3,d0,a3 highest fire safety, and zero-corrosive-gas emissions: [email protected] | Industrial Drive Solutions Division | Anhui Feichun Special Cable Co., Ltd.

CPR Cca-s3,d0,a3 Building Code[email protected]
HEPR Halogen-Free Insulation[email protected]
Zero Corrosive Gas Emissions[email protected]
Industrial Drive Solutions DivisionAnhui Feichun Special Cable Co., Ltd.

GAALFLEX® VFD FG16OHH2R16: 600V/1000V CPR EU 305/2011 Building-Code Compliant Halogen-Free VFD Cable with HEPR Rubber Insulation & Cca-s3,d0,a3 Fire Safety — 600V/1000V building-code VFD cable, CPR EU 305/2011 Cca-s3,d0,a3 highest fire safety, HEPR type G16 halogen-free rubber insulation, gray RAL 7035 low-smoke PVC R16 jacket (zero HCl/PFTE emission), flexible Class 5 red copper per IEC 60228, aluminum tape (100% covering) + red copper braid shielding, 3-phase brown/black/gray + shield per DIN VDE 0293-308, 2.5–240 mm² building spectrum, 10×D minimum bending radius (building conduit-optimized), temperature −15 to +90°C moderate building, +250°C short-circuit, 4 kV test voltage, CEI 20-22 II / CEI EN 60332-3-24 Cat. C / IEC 60332-3-24 Cat. C fire-retardant, EN 50575:2014+A1:2016 halogen-free building compliance, suitable per EN 55011/DIN VDE 0875/EN 61800-3, RoHS & CE certified. Comprehensive portfolio (12+ building SKUs) for European residential/commercial/industrial building motor VFD systems.

European CPR building-code VFD cable for building installations: 600V/1000V dual-voltage CPR EU 305/2011 building standard specification, highest Cca-s3,d0,a3 fire safety classification for building occupant protection, HEPR halogen-free insulation eliminating toxic HCl gas release during fire, low-smoke formulation minimizing evacuation impairment, zero corrosive gas emissions protecting building electronics/equipment, moderate temperature range (−15 to +90°C) for standard building environments, flexible 10×D installation through building conduits and junction boxes, complete 2.5–240 mm² building motor spectrum, and comprehensive European building-code industrial automation infrastructure with proprietary HEPR halogen-free design, CPR Cca-s3,d0,a3 maximum fire safety, zero-corrosive-gas-emission performance, and professional building-code-compliant frequency converter system integration for residential, commercial, and industrial building installations.