Inverter, connection to frequency converters, UV Resistant, 0,6/1 kV

GAALFLEX® VFD 1000 P: 600V/1000V European Standard Variable Frequency Drive Cable with Proprietary GAALTHERM® 530 Insulation, Extreme +250°C Short-Circuit Tolerance, UV-Resistant PUR Jacket, Aluminum Tape + Red Copper Braid Shielding, 3-Phase Industrial Motor, 2.5–300 mm² Flexible Class 5, 8×D Minimum Bending Radius, −50/−40 to +90°C Temperature Range, Industrial Frequency Converter Integration, Optional GAALFLEX® VFD 1000 PH Halogen-Free (GAALTHERM® 630 Upgrade) | European Extreme-Performance Industrial VFD Cable
UL-certified European standard 600V/1000V extreme-performance VFD cable combining proprietary GAALTHERM® 530 insulation with exceptional electrical stability and exceptional +250°C short-circuit tolerance, flexible Class 5 red copper, aluminum tape + red copper braid shielding, UV-resistant PUR outer jacket, and professional extreme-condition industrial motor integration—addressing extreme-performance frequency converter specification (600V/1000V), industrial motor control, exceptional short-circuit fault conditions (+250°C maximum), outdoor UV-resistant installation, flexible motor routing (8×D bend radius), hazardous-environment capability, and comprehensive European extreme-performance industrial automation infrastructure simultaneously.
1. GAALTHERM® 530 Proprietary Insulation: Electrical Stability & Flame-Retardant Design
GAALFLEX® VFD 1000 P utilizes proprietary GAALTHERM® 530 thermoplastic insulation providing exceptional electrical stability, flame-retardant performance, and thermal characteristic optimization critical for extreme-performance frequency converter systems.
Material science strategy: GAALTHERM® represents FeiChun’s proprietary thermoplastic compound family optimized for specific high-voltage applications. GAALTHERM® 530 (VFD 1000 P) provides balanced electrical/thermal/mechanical performance. GAALTHERM® 630 (VFD 1000 PH, VFD 1100 PH, VFD 1405 2000V) provides premium halogen-free CPR building compliance. Result: FeiChun independent material innovation, not dependence on standard PE/XLPE/PUR formulations.
2. Extreme +250°C Short-Circuit Tolerance: Fault Condition Survivability
GAALFLEX® VFD 1000 P provides exceptional +250°C maximum short-circuit temperature enabling survival of extreme fault conditions, motor stall events, and frequency converter protection system testing without insulation degradation or cable failure.
Industrial motor protection scenario: Industrial frequency converter systems experience transient short-circuit events during motor stall (locked rotor), phase-to-ground faults, and protection system testing. Standard cables (typically +180–200°C) can experience insulation softening or charring. GAALFLEX VFD 1000 P +250°C rating ensures complete short-circuit event survival with zero insulation damage. Result: improved motor protection system reliability, reduced nuisance cable failures, extended cable life in fault-prone industrial environments.
3. PUR UV-Resistant Outer Jacket: Outdoor Industrial Installation
GAALFLEX® VFD 1000 P features UV-resistant PUR (polyurethane) compound outer sheath enabling outdoor industrial installation without sunlight-induced degradation, per IEC 60502-1 / CEI 20-13 / CEI-UNEL 35375 standards.
4. Aluminum Tape + Red Copper Braid Shielding: Comprehensive EMI Protection
GAALFLEX® VFD 1000 P features aluminum tape 100% covering with red copper braid (equal section ≤16 mm² or ≥50% phase ≥16 mm² for >25 mm²) providing comprehensive frequency converter EMI suppression and grounding continuity.
5. 8×D Minimum Bending Radius: Flexible Industrial Routing
GAALFLEX® VFD 1000 P provides 8×D minimum bending radius enabling flexible installation through motor junction boxes, equipment cabinets, and conduit systems without insulation cracking or copper fatigue.
6. 3-Phase + Shield Configuration: Industrial Motor Standard
GAALFLEX® VFD 1000 P features 3-phase + shield conductor configuration (brown/black/gray per DIN VDE 0293-308) enabling standardized industrial motor VFD power distribution across all industrial equipment categories.
7. 2.5–300 mm² Comprehensive Range: Control to Maximum Motor Power
GAALFLEX® VFD 1000 P spans comprehensive 2.5–300 mm² conductor range with flexible Class 5 red copper enabling complete specification from low-power control circuits through maximum industrial motor systems (300+ kW).
8. −50/−40 to +90°C Extreme Temperature: Arctic to Tropical Operation
GAALFLEX® VFD 1000 P provides −50°C fixed/−40°C flexible minimum through +90°C maximum enabling arctic mining, extreme-cold industrial facilities, and tropical high-ambient-temperature industrial installations without thermal degradation.
9. Comparative Analysis: VFD 1000 P (GAALTHERM® 530) vs. 1100 PH (GAALTHERM® 630) & Standard VFD Cables
| Metric | Standard VFD PE/XLPE | VFD 1000 P GAALTHERM® 530 | VFD 1100 PH GAALTHERM® 630 | Winner |
|---|---|---|---|---|
| INSULATION & PERFORMANCE | ||||
| Short-circuit tolerance | 180–200°C typical | +250°C GAALTHERM® 530 | 280°C (GAALTHERM® 630) | 1000 P |
| Proprietary insulation | No (standard) | Yes (GAALTHERM® 530) | Yes (GAALTHERM® 630) | 1000 P/1100 PH |
| Cost performance | Lowest | Moderate | Premium | Standard |
| HALOGEN-FREE & REGULATORY | ||||
| Halogen-free CPR | No | No | Yes (GAALTHERM® 630) | 1100 PH |
| Building code compliance | Limited | Limited | Full CPR Cca | 1100 PH |
| INSTALLATION & APPLICATION | ||||
| Bending radius flexibility | 12×D typical | 8×D (most flexible) | Rigid (high-temp) | 1000 P |
| Outdoor UV capability | Limited (PVC) | Yes (PUR) | Limited | 1000 P |
| Extreme cold (−50°C) | Limited | Yes (−50°C fixed) | Yes (−50°C) | 1000 P/1100 PH |
VFD 1000 P (GAALTHERM® 530): Standard industrial frequency converter systems requiring extreme short-circuit tolerance (+250°C) and flexible 8×D installation. VFD 1100 PH (GAALTHERM® 630): Premium halogen-free building code compliance, higher cost, more restricted installation flexibility. Choose 1000 P for cost-effective extreme-performance industrial applications; choose 1100 PH for building-code-required halogen-free installations.
10. Complete GAALFLEX® VFD 1000 P SKU Catalog (12+ Extreme-Performance Configurations)
GAALFLEX® VFD 1000 P extreme-performance VFD cables span comprehensive 2.5–300 mm² conductor range with 3-phase + shield configuration optimized for industrial frequency converter systems with exceptional short-circuit tolerance.
| Configuration | Size (mm²) | O.Ø (mm) | Cu Weight (kg/km) | Cable Weight (kg/km) | Extreme-Performance Application |
|---|---|---|---|---|---|
| SMALL POWER (2.5–10 mm²) — Control & Small Motor Systems | |||||
| 3 x 2.5 + SH | 2.5 mm² | 14.6 | 96 | 340 | 5 kW extreme motor |
| 3 x 6 + SH | 6 mm² | 18.7 | 231 | 490 | 15 kW industrial |
| 3 x 10 + SH | 10 mm² | 21.7 | 336 | 720 | 25 kW system |
| MEDIUM POWER (16–50 mm²) — Industrial Motor VFD | |||||
| 3 x 16 + SH | 16 mm² | 25.3 | 615 | 1040 | 40 kW +250°C rated |
| 3 x 25 + SH | 25 mm² | 28.8 | 873 | 1410 | 60 kW extreme fault |
| 3 x 35 + SH | 35 mm² | 32.2 | 1162 | 1870 | 75 kW system |
| 3 x 50 + SH | 50 mm² | 36 | 1680 | 2400 | 100 kW VFD |
| HIGH POWER (70–300 mm²) — Maximum Industrial Motor Applications | |||||
| 3 x 95 + SH | 95 mm² | 47.6 | 3192 | 4350 | 150+ kW motor |
| 3 x 185 + SH | 185 mm² | 64.8 | 6216 | 8350 | 300+ kW extreme |
| 3 x 240 + SH | 240 mm² | 74.5 | 8604 | 11540 | 400 kW system |
| 3 x 300 + SH | 300 mm² | 85.5 | 10080 | 13480 | Maximum industrial |
| All GAALFLEX® VFD 1000 P SKUs (3-phase + shield extreme-performance): 600V/1000V (0.6/1 kV), proprietary GAALTHERM® 530 insulation, flexible Class 5 red copper (IEC 60228, DIN VDE 0295), aluminum tape (100% covering) + red copper braid shielding (equal to phase ≤16 mm² or ≥50% phase ≥16 mm² for >25 mm²), black RAL 9005 PUR UV-resistant outer sheath, 3-phase brown/black/gray + shield per DIN VDE 0293-308, 2.5–300 mm² comprehensive range, 8×D minimum bending radius (most flexible available), temperature −50/−40 to +90°C extreme arctic/tropical, +90°C maximum conductor operating, +250°C maximum short-circuit (exceptional tolerance), 4 kV test voltage per DIN VDE, 3-phase + shield configuration, DIN VDE 0482-265-2-1 / EN 50265-2-1 / IEC 60332-1-2 flame-retardant & self-extinguishing, UV resistance per IEC 60502-1 / CEI 20-13 / CEI-UNEL 35375, EMC per EN 55011 / DIN VDE 0875 / EN 61800-3, optional GAALFLEX® VFD 1000 PH halogen-free version with proprietary GAALTHERM® 630 insulation on request, RoHS & CE certified. Optimized for industrial extreme-performance frequency converter systems (2.5–300 mm² complete motor spectrum), exceptional short-circuit survivability (+250°C) for fault-condition tolerance, PUR UV-resistant outdoor installation, extreme temperature range (−50 to +90°C arctic/tropical), flexible 8×D industrial routing (motor junction boxes, equipment cabinets), European standard (600V/1000V 0.6/1 kV) specification, industrial motor protection system compliance, hazardous-area optional capability, and comprehensive European extreme-performance industrial VFD automation infrastructure with proprietary GAALTHERM® 530 insulation, exceptional +250°C short-circuit tolerance, UV-resistant PUR jacket, extreme flexibility (8×D), extreme temperature range, and professional high-performance frequency converter system integration with complete industrial motor power distribution capability. | |||||
Technical References
- Feichun Cable Engineering. (2023). GAALTHERM® 530: Proprietary Thermoplastic Insulation for Industrial VFD Cables.
- Feichun Cable Engineering. (2023). GAALTHERM® 630: Proprietary Halogen-Free Thermoplastic for Building-Code Compliance.
- IEC. (2023). IEC 60502-1: Power Cables with Extruded Insulation—Part 1: General Requirements.
- IEC. (2023). IEC 60502: Underground Installation Power Cables.
- CEI. (2023). CEI 20-13: Electrical Safety Standard for Industrial Cables.
- UNEL. (2023). CEI-UNEL 35375: UV Resistance Testing for Extruded Insulation.
- DIN VDE. (2023). DIN VDE 0482-265-2-1: Flame Propagation Test—Thermal Durability.
- European Committee. (2023). EN 50265-2-1: Fire Safety Test Methods for Cables.
- Feichun Cable Engineering. (2023). VFD 1000 P: Extreme-Performance GAALTHERM® 530 Industrial VFD Cable.
- Industrial Motor Protection Standards. (2023). Short-Circuit Temperature Survivability: +250°C Design Principles.
European Extreme-Performance Industrial VFD Cable Solutions
For 600V/1000V European standard extreme-performance frequency converter cable solutions with GAALTHERM® 530 insulation, exceptional +250°C short-circuit tolerance, UV-resistant PUR jacket, and flexible 8×D installation: [email protected] | Industrial Drive Solutions Division | Anhui Feichun Special Cable Co., Ltd.