RONDOFLEX® (C)-FC(N)GRDGCGOEU
RONDOFLEX® (C)-FC (N)GRDGCGOEU-J Technical Specifications (DIN VDE 0250-814)
Parameter Specification
Standard DIN VDE 0250-814 (with ref. to). Feichun equivalent: PROTOLON® (FL) FEST-PWR Series.
Voltage Rating (U₀/U) 0.6/1 kV. Max operating: 1.2 kV. Test voltage: 5 kV. Peak voltage: 2,400 V. VFD Umax: 690 V.
Conductor Material FC-FLX™ Tongling bare copper, 99.97%+. Class 5 = flexible. PE conductor: Class FS = exceptionally fine stranded, tinned.
Insulation Rubber 3GI3 (EPR with semi-conductive stress-control layer). 90°C continuous / 250°C short-circuit.
Inner Sheath Rubber GM1b. High-grade flexible rubber for intermediate protection.
Screen Tinned copper braid, 80% optical coverage. EMC/EMI shielding for VFD output containment.
Outer Sheath Gummi (Rubber) 5GM3. Black. Flame-retardant (IEC 60332-1-2). UV-resistant. Oil-resistant (EN 60811-404). Ozone-resistant.
Temperature Range Fixed: −50°C to +80°C. Moving: −35°C to +80°C.
Bending Radius Fixed: 4 × OD. Moving: 5 × OD.
Tensile Strength 15 N/mm² × total Cu cross-section.
Operating Speed (Festoon) 240 m/min.
Bending Direction Unidirectional — optimised for festoon trolley systems.
Core Identification Green-yellow + numbers.
REACH Note Contains MCCP (Medium-chain chlorinated paraffins) > 0.1% per REACH candidate list.